CONSTRUCTION HEATER
GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, AND CARBON MONOXIDE POISONING. ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER. IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC. CONTACT THE MANUFACTURER.
WARNING: FIRE, BURN, INHALATION,
AND EXPLOSION HAZARD. KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING MATERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS. NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNER, DUST PARTICLES OR UNKNOWN CHEMICALS.
OPERATING INFORMATION Intended use is primarily the temporary heating of buildings under construction, alteration or repair.
WARNING
NOT FOR HOME OR RECREATIONAL VEHICLE USE.
This is a propane, direct-fired heater. Propane is heavier than air. If propane leaks from a connection or fitting, it sinks to the floor, collecting there with the surrounding air, forming a potentially explosive mixture. Obviously, propane leaks should be avoided, so set up the propane supply with utmost care. Leak check new connections or reconnections with a soap and water solution and follow all connection instructions herein. Also, ask your propane dealer for advice on the propane supply installation and ask him to check it if there are any questions. Direct-Fired means that all of the combustion products enter the heated space. Even though this heater operates very close to 100 percent combustion efficiency, it
still produces small amounts of carbon monoxide. Carbon monoxide (called CO) is toxic.
CO can build up in a heated space and failure to provide adequate ventilation could result in death. The symptoms of inadequate ventilation are:
headache dizziness burning eyes and nose nausea
dry mouth or sore throat So, be sure to follow advice about ventilation in these operating instructions.
SAFETY PRECAUTIONS
1. Check the heater thoroughly for damage. DO NOT operate a damaged heater.
2. DO NOT modify the heater or operate a heater which has been modified from its original condition.
3. Use only propane gas.
4. Use only VAPOR WITHDRAWAL propane supply. If there is any question about vapor withdrawal, ask your propane dealer.
5. Mount the propane cylinders vertically (shutoff valve up). Secure them from falling or being knocked over and protect them from damage.
6. Locate propane containers at least 7 ft. from the heater and do not direct exhaust toward containers.
7. Use only the hose and regulator assembly provided with the heater. Inspect hose assembly before each use of the heater. If there is excessive abrasion or wear, or hose is cut, replace with hose assembly listed on parts list before using heater.
8. For indoor use only. Area must be well ventilated. Provide minimum openings of 2 sq. ft. near the floor and 2 sq. ft. near the ceiling (also see "Operating Information").
9. If at any time gas odor is detected, IMMEDIATELY DISCONTINUE operation until the source of gas has been located and corrected.
10. Install the heater such that it is not directly exposed to water spray, rain and/or dripping water or wind.
11. Maintain minimum clearance from normal combustible material (like paper) of 6 ft. in all directions. Locate 10 ft. from canvas or plastic tarpaulins or similar coverings and secure them to prevent flapping or movement due to wind action.
12. Operate only on a stable, level surface.
13. Do not use on combustible floors.
14. Caution: Do not touch heater surface during operation or for 30 minutes after shutdown. It can cause serious burns.
15. Do not move, handle or service while hot or burning.
16. Use only in accordance with local codes or, in the absence of local codes, with the Standard for the Storage and Handling of Liquefied Petroleum Gases ANSI/NFPA 58-1998.
OPERATING INSTRUCTIONS
PREPARING FOR OPERATION
1.Check the heater for possible shipping damage. If any is found, immediately notify your dealer.
2.Follow all of the "Safety Precautions" on page 1, "Propane Fuel Information on page 4 and "Operating Information" on page 1.
3.Connect the POL fitting of hose and regulator assembly to the propane cylinder by rotating the POL nut counter clock wise into the propane cylinder's valve outlet and securely tighten with a wrench.
4.Connect the hose to the heater.
5.Securely tighten all gas connections.
6.Open the cylinder's gas valve and check all gas connections with a soap and water solution. DO NOT USE A FLAME.
START
1.WARNING: BEFORE LIGHTING PILOT, fully close the ball valve (turn handle perpendicular to valve body).
2.Fully open the valve on the propane cylinder.
3.Depress red button on safety pilot valve admitting gas to the pilot. Push and release the piezo button until the pilot lights, multiple tries may be necessary. Alternately place a lighted match near the pilot (pilot is above cutout in the middle pan). If the hose is filled with air, allow a few minutes for gas to reach the pilot.
4.When the pilot lights, continue to hold the button on the safety pilot valve depressed for 30 seconds, then release.
5.If the pilot goes out, wait 5 minutes and repeat the start procedure.
6.When the pilot remains lit, open the ball valve to light the main burner (turn handle parallel with valve body) .
CAUTION: Adjusting burn rate to lower than design can cause sooting.
STOP
1.Securely close valve on the propane cylinder.
2.Close the ball valve (handle perpendicular to valve body).
RESTART AFTER SAFETY SHUTDOWN
1.Securely close valve at propane cylinder.
2.Wait 5 minutes.
3.Restart following "Start" procedure.
CAUTION
When the heater is to be operated in the presence of other people the user is responsible for properly acquainting those present with the safety precautions, and of the hazards involved.
SERVICING
A hazardous condition may result if a heater is used that has been modified or is not functioning properly. When the heater is working properly:
* The flame is contained within the heater. * The flame is essentially blue. * There is no strong disagreeable odor, eye burning or
other physical discomfort.
* There is no smoke or soot internal or external to the
heater.
* There are no unplanned or unexplained shutdowns of
the heater.
The parts list shows the heater as it was constructed. Do not use a heater which is different from that shown. In this regard, use only the hose, regulator and cylinder connection fitting (called a POL fitting) supplied with the heater. Do not use alternates. For this heater, the regulator must be set to supply 11" W.C. pressure. If there is any uncertainty about the regulator setting, have it checked.
A heater which is not working right must be repaired, but only by a trained, experienced service person. Contact the factory for the service center closest to you, phone number (909) 981-5343.
You may also obtain in-warranty or out-of-warranty service by returning the product postage prepaid to :
Scheu Products Company
8855 Baker Avenue
Rancho Cucamonga, CA 91730
In-warranty products returned to the Service Department will be repaired with no charge for either parts or labor and will be returned to you postage prepaid. Please include a brief statement indicating date, place of purchase, the nature of the problem and proof of purchase.
MAINTENANCE AND STORAGE
1.The heater should be inspected before each use, and at least annually by a qualified person.
2.Before each use, check the soft "O" ring seat at the bullĀ­nose of the POL fitting. If the "O" ring is cut, scuffed, otherwise damaged, replace it with part number 6681.
3.Turn off the gas at the LP-gas supply cylinder(s) when the heater is not in use.
4.When the heater is to be stored indoors, the connection between the LP-gas supply cylinder(s) and the heater must be disconnected and the cylinder(s) removed from the heater and stored outdoors and in accordance with Chapter 5 of the standard for Storage and Handling of Liquefied Petroleum Gases ANSI/NFPA 58-1998.
Page 2
Out-of-warranty products returned to the Service Department will be repaired with a charge for parts and labor and will be returned to you postage collect.
Loading...