FOR YOUR SAFETY
— Do not store or use gasoline or any other flammable
vapors or liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS :
• Do not touch any electrical switch;
• Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
VENTED DECORATIVE NATURAL GAS LOGS
OWNER’S OPERATION AND INSTALLATION MANUAL
RGA 2-72
APPROVED
TESTED AND
LISTED BY
VANGUARD BURNER MODELS
VVSR18, VVSR24, VVDR18, VVDR24, AND VVDR30
FOR USE WITH LOG SET MODELS VSLR18, VSLR24, VDLCR18,
VDLCR24 (SHOWN) AND VDLCR30
FMI BURNER MODELS
FVSR18, FVSR24, FVDR18, FVDR24, AND FVDR30 FOR USE
WITH LOG SET MODELS FSLR18, FSLR24, FDLCR18, FDLCR24,
FDLCR30, FA18, FA24 AND FA30
COMFORT GLOW LOG SET AND BURNER MODELS
CVSR18, CVSR24, CPVSR18, CPVSR24, CVDR18, CVDR24,
CVDR30, LBFL18, LBFL24, LVDR18, LVDR24, LVDR30, BFLT18,
BFLT24, HVSR18, HVSR24, HCVDR18 AND HCVDR24
www.desatech.com
901265-01P2
WARNING: Improper installation, adjustment, altera­tion, service or maintenance can cause injury or prop­erty damage. Refer to this manual for correct installation and operational procedures. For assistance or addi­tional information consult a qualified installer, service agency or the gas supplier.
WARNING: This is a gas-fired appliance. It uses air (oxy­gen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to the National Fuel Gas Codes, ANSI Z233.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation.
WARNING: This appliance is for installation only in a solid­fuel burning masonry or UL127 factory-built fireplace, con­structed of noncombustible material, and connected to a working flue. (See page 5 for minimum flue opening.)
This appliance may be installed in an aftermarket*, per­manently located, manufactured (mobile) home, where not prohibited by state or local codes.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.
State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.
TABLE OF CONTENTS
Safety Information ............................................... 3
Local Codes ........................................................ 4
Unpacking ........................................................... 4
Product Identification ........................................... 4
Optional Product Features .................................. 5
Installation .......................................................... 5
Operating Appliance .......................................... 13
Cleaning and Maintenance ................................ 15
Service Hints ..................................................... 15
Technical Service .............................................. 15
Replacement Parts ............................................ 15
Troubleshooting ................................................. 16
Accessories ....................................................... 19
Illustrated Parts Breakdown and Parts List ....... 20
Warranty Information ...........................Back Cover
www.desatech.com
901265-01P 3
WARNING: This appliance is equipped for natural gas. An optional propane/LP conversion kit must be installed for use with propane/LP gas.
WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns.
WARNING: Installed decora­tive glass door enclosures must be fully opened when operating this gas appliance.
Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
Do not place clothing or other flammable material on or near the appliance. Never place any objects on the appliance.
Appliance assembly becomes very hot when in use. Keep chil
­dren and adults away from hot surface to avoid burns or clothing ignition. Appliance will remain hot for a time after shutdown. Allow surface to cool before touching.
Carefully supervise young chil
­dren when they are in the room with appliance.
You must operate this appliance with a fireplace screen in place. Make sure fireplace screen is closed before running appliance.
Keep the appliance area clear and free from combustible ma
­terials, gasoline and other flam
­mable vapors and liquids.
SAFETY INFORMATION
WARNING: This product con­tains and/or generates chemicals known to the State of California to cause cancer or birth defects or other reproductive harm.
WARNING: Keep flue open when operating unit.
IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate or service this log set. Improper use of this log set can cause serious injury or death from burns, fire, explosion, electrical shock and carbon monoxide poisoning.
DANGER: Carbon monoxide poisoning may lead to death!
Carbon Monoxide Poisoning: Early signs of
carbon monoxide poisoning resemble the flu, with headaches, dizziness or nausea. If you have these signs, the log set may not be working properly. Get fresh air at once! Have log set serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol and those at high altitudes.
Natural Gas: Natural gas is odorless. An odor-
making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.
Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this log set.
WARNING: Any change to this log set or its controls can be dangerous.
WARNING: Do not use a blow­er insert, heat exchanger insert or other accessory not approved for use with this appliance.
www.desatech.com
901265-01P4
1. If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not use any phone in your building
• immediately call your gas supplier from a neighborʼs phone. Follow the gas supplierʼs instructions
• if you cannot reach your gas supplier, call the fire department
2. Never install the log set
• in a recreational vehicle
• where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the log set
• in high traffic areas
• in windy or drafty areas
3. Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. Inspect chimney flue for damage. If dam
-
aged, repair flue before operating appliance.
4. This log set is designed to be smokeless. If logs ever appear to smoke, turn off appliance and call a qualified service person. Note: During initial operation, slight smoking could occur due to log curing and the burning of manufacturing residues. You may wish to add more ventilation by opening a window.
5. To reduce the creation of soot, follow the instructions in Cleaning and Maintenance
,
page 15.
6. The installation and provisions for combustion and ventilation air must conform with the Na
­tional Fuel Gas Code, ANSI Z233.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation
.
7. Do not run log set
• where flammable liquids or vapors are used
or stored
• under dusty conditions
8. Do not burn solid fuel in the fireplace after installing the log set. Do not use this log set to cook food or burn paper or other objects.
9. Do not use appliance if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the room appliance and to replace any part of the control system (if using GA9050A or GA9150A) and any gas control which has been under water.
SAFETY INFORMATION
Continued
Figure 1 - Product Identification
(Dual Burner Shown)
Hearth Kit Model ___________________ Serial Number _____________________ Log Set Model _____________________
Grate
Burner Pan
Burner Manifold
Burner Inlet Fitting
Burner Clamp
Grate Steps
PRODUCT IDENTIFICATION
10. To help prevent breakage, new logs must be broken-in (see Curing Logs page 14).
11. Turn log set off and let cool before servicing, installing, or repairing. Only a qualified ser
­vice person should install, service, or repair log set.
12. Provide adequate clearances around air openings.
LOCAL CODES
Install and use log set with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
UNPACKING
CAUTION: Do not remove the data plates from the burner pan. The data plates contain impor­tant product information.
1. Remove logs, hearth kit, pan materials, and hardware from carton.
2. Remove all protective packaging applied to logs and base for shipment.
3. Check all items for any shipping damage. If damaged, promptly inform dealer where you bought the product.
www.desatech.com
901265-01P 5
OPTIONAL PRODUCT
FEATURES
ON/OFF SAFETY VALVE/PILOT KIT AND PROPANE/LP CONVERSION
An optional valve/safety pilot kit with a piezo ignitor is available for this appliance. This system requires no matches, batteries, or other sources to light. You must use this optional system for LP conversion. See Accessories, page 19.
REMOTE CONTROL READY (MILLIVOLT) SAFETY VALVE/ PILOT KIT
An optional millivolt valve/safety pilot kit with a piezo ignitor is available for this appliance. This system requires no matches, batteries, or other sources to light. This system may be connected to a wall switch or hand-held wireless remote control. See Accessories, page 19.
REMOTE CONTROL ACCESSORIES
There is an optional hand-held ON/OFF remote control that can be purchased separately for this log set. You must use the millivolt valve/safety pilot kit to use remote accessories with this appliance. See Accessories, page 19.
A wall switch is also available for this appliance. You must use the millivolt valve/safety pilot kit to use the wall switch with this appliance. See Accessories, page 19.
INSTALLATION
CAUTION: Do not remove the data plates attached to the burner pan. The data plates contain important warranty and safety information.
WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chim­ney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and distribute soot within the house. Inspect chimney flue for damage. If damaged, repair flue before operating heater.
NOTICE: Installation, service, and repair of this appliance must be performed by a qualified installer, service agency, company or gas supplier experienced with this type of gas appliance. Only factory authorized components listed in these instructions may be used in accordance with the manufacturer’s instructions and all codes and requirements of the authority having jurisdiction. Any modifications to this kit, or use of unauthorized components or accessory items will void the manufacturer’s warranty, and may result in a hazardous condition.
FLUE OPENING SPECIFICATIONS
Note: This vented appliance must be installed only in a solid-fuel burning fireplace with a working flue and constructed of noncombustible material.
The charts in Figure 2, page 6, indicate technical infor­mation regarding the installation of your gas log set. Please make sure that all of the specifications shown are applicable before installation is attempted.
The fireplace must include a working flue and venting system with the minimum openings shown in the Figure 2, page 6.
www.desatech.com
901265-01P6
BURNER ORIFICE
LOG NATURAL PROPANE/LP
SIZE IN. NUM. IN. NUM.
VV/FV/CV/CPV/ HV/SR18 VV/FV/CV/HCV/ LV/DR18
.120 31 .073 49
VV/FV/CV/CPV/ HV/SR24 VV/FV/CV/ HCV/LV/DR24, LBFL18, BFLT18
.129 30 .086 44
VV/F V/ CV/LV/ DR30, LBFL24, BFLT24
.1405 28 .089 43
Model
Burner
Description
Btu Input
Natural Gas
Btu Input
Propane/LP
Gas
Minimum
Vent
Opening
VVSR18 FVSR18
HVSR18
CPVSR18
CVSR18
18"
Single
50,000 40,000 8" dia.
VVSR24 FVSR24
HVSR24
CPVSR24
CVSR24
24"
Single
60,000 50,000 8" dia.
VVDR18
FVDR18
HCVDR18
LVDR18
CVDR18
18"
Dual
55,000 45,000 8" dia.
VVDR24
FVDR24
CVDR18
HCVDR24
LVDR24
CVDR24
24"
Dual
65,000 55,000 8" dia.
VVDR30
FVDR30 LVDR30
CVDR24
30"
Dual
70,000 60,000 8" dia.
LBFL18 BFLT18
18"
Triple
65,000 55,000 8" dia.
LBFL24 BFLT24
24"
Triple
70,000 60,000 8" dia.
*Add 6" if safety valve/pilot is used **At depth indicated
FUEL INLET PRESSURE SPECIFICATIONS (W.C.)
Min. Max.
NG 5.5" 10.5"
LP 11" 13"
Figure 2 - Technical Information Charts
MINIMUM FIREBOX SIZES
Models: VVSR18, FVSR18, HVSR18, CPVSR18, CVSR18, CVDR18, VVDR18, FVDR18, HCVDR18, LVDR18
Front Width* Back Width** Depth Height
28" 16" 14" 18"
Models: VVSR24, FVSR24, HVSR24, CPVSR24, CVSR24, CVDR24, VVDR24, FVDR24, HCVDR24, LVDR24
Front Width* Back Width** Depth Height
29 3/4" 17" 15 1/2" 18"
Models: VVDR30, FVDR30, LVDR30, CVDR30
Front Width* Back Width** Depth Height
36" 27" 18" 18" Models: LBFL18, BFLT18 Front Width* Back Width** Depth Height
28" 16" 15 1/2" 18" Models: LBFL24, BFLT24 Front Width* Back Width** Depth Height
30" 22" 15 1/2" 18"
INSTALLATION
Continued
Loading...