Desa CGESBL User Manual

27" MODEL CGESBL AND
18" MODEL CGESBMR
ELECTRIC STOVE WITH REMOTE CONTROL
Read these instructions completely before operating electric stove. Failure to follow them could cause a heater malfunction resulting in serious injury and/or property damage.
Save this manual for future reference.
For more information, visit www.desatech.com
TABLE OF CONTENTS
Safety Information ............................................... 2
Listing A
pprovals ................................................. 3
Unpacking and Testing the Unit ........................... 3
Product DimensionS & Specifications ................. 3
Grounding Instructions ........................................ 4
Operating Instructions ......................................... 4

SAFETY INFORMATION

WARNING: Improper installa­tion, adjustment, alteration, ser­vice or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information, consult a qualified installer.
WARNING: Risk of fire - keep combustible material away from the front of the heater. Keep elec trical codes, drapery and other furnishings at least 3 feet from the front and sides of electric stove.
WARNING: Servicing should be done only while the heater is disconnected from the power supply circuit.
CAUTION: For lower lamps (ember bed) and flame generation lamps, replace only with lamp type GX6.35 rated 120V, 35W max. For upper lamps (top contrasting light) replace only with lamp type GX6.35, rated 120V , 20W max.
Your electric stove is classified as an electric heater. As with any electrical appliance and par ticularly with electric heaters, basic precautions must be followed in order to reduce the risk of fire, burns, electrical shocks and/or other serious injuries or death.
1. Read all instructions before using this heater.
2. The unit can become hot when in use. To avoid accidental burns, do not allow bare skin to come into contact with the hot surfaces of the unit. Keep children and pets away from unit when in use.
2
-
www.desatech.com
Cleaning and Maintenance .................................. 6
Technical Service ................................................
Replacement Parts .............................................. 8
Troubleshooting ...................................................
Warranty Information ............................
3. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes and curtains at least 3 feet from heater. Do not use this unit in areas where gasoline, paint or other flam­mable liquids or their associated vapors may be present.
4. Do not use this unit for drying wet clothes.
5. Do not operate unit if it is damaged or has mal functioned. If you suspect the unit is damaged, return it to an authorized service facility for examination, electrical or mechanical adjust ment or repair.
6. Do not use this unit outdoors.
7. Do not use or install this unit in areas prone to dampness or where it may come into contact with water. This heater is not intended for use in bathrooms, laundry areas or other locations where water may be present.
8. To reduce the risk of fire, do not place or install this unit in areas where the ventilation or circulation ducts may become blocked.
9. Do not insert or allow foreign objects to enter any of the ventilation or circulation ducts as this may cause electric shock, fire or otherwise damage the unit.
10. The unit's power supply cord must be con nected to a properly grounded and protected, 120-volt electrical outlet. Always use ground fault protection where required by the electri cal code. To reduce the risk of fire, avoid run­ning power supply cord under rugs, carpets, etc. Keep the power supply cord away from high traffic area where it may pose a tripping hazard.
-
11. Avoid the use of an extension cord because the extension cord may overheat and cause a risk of fire. However, if you have to use an extension cord, the cord should be No. 14 AWG minimum size with a grounding plug and rated not less than 1875 WATTS.
Back Page
117190-01A
8
9
-
-
-
-
SAFETY INFORMATION
27"
15"
26"
12.5"
25.25"
18"
Continued
12. Always disconnect the unit from the power supply before performing any cleaning, light bulb replacement, maintenance, relocating the heater or when the unit is not in use for long periods of time.
13. When transporting or storing the unit, keep it in a dry location, free from dust, excessive vibration or other factors, which may damage the unit.

LISTING APPROVALS

This heater has been tested in accordance with the CSA Standards for fixed and location-dedicated electric room heaters in the United States. All components are UL or CSA safety certified.
If you need assistance during installation, please con tact your local dealer or the DESA Heating Products Technical Services Department at 1-866-672-6040.
UNPACKING AND
TESTING THE UNIT
Carefully remove the unit from the box. Prior to permanently installing the unit, test to make sure the unit operates properly by plugging the power supply cord into a conveniently located 120-volt grounded outlet.
PRODUCT DIMENSIONS &
SPECIFICATIONS
CGESBL Remote Controlled
27" Electric Stove
-
CAUTION: The unit's power supply cord must be connected to a properly grounded and pro­tected 120-volt outlet. Always use ground fault protection where required by the electri cal code.
WARNING: Do not operate the unit if it is damaged or has malfunctioned . If you suspect the unit is damaged, return the unit to an authorized service facility for examination, electrical or me­chanical adjustment or repair.
117190-01A
www.desatech.com
CGESBMR Remote Controlled
18" Electric Stove
Figure 1 - Heater Dimensions
Frequency 60 Hz
-
Heater Power 1500 W Heater Output 5000 BTUs Power Supply 120V; 15 Amp Grounded, Circuit
Note: A dedicated power supply circuit is recom­mended for the unit but not required. Additional electrical appliances on the same circuit may ex­ceed the current (amperage) rating for that circuit. If after the installation of your unit, the circuit breaker trips or the fuse fails on a repeated basis, then a dedicated circuit will likely be required. Any new wiring must be done in compliance with local and national codes and other applicable regula­tions in order to reduce the risk of fire, electric shock or other injuries. Therefore, it is strongly recommended that you hire a licensed electrician to complete any such work.
3
GROUNDING
INSTRUCTIONS
This stove is for use on 120 volts. The cord has a plug as shown in Figure 2. An adapter is available for connecting three-blade grounding-type plugs to two-slot receptacles. The green grounding lug extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box. The adapter should not be used if a three-slot grounded receptacle is available.
Grounding Pin
Figure 2 - Grounding Methods
Adapter
OPERATING
INSTRUCTIONS
Once the unit has been properly connected to a ground electrical outlet, it is ready to operate.
Note: Ensure the circuit breakers for power supply are turned on.
CONTROL PANEL OPERATION
Controls are located on the back of the unit (see Figure 3).
1. Main ON/OFF power switch: This switch is located at the furthest right corner on the control panel when looking at the back of the unit. Turn the switch to ON and unit will be ready to operate. The "|" indicates ON and "O" indicates OFF.
IMPORTANT: Once you turn the main switch to the ON posi­tion, the remote control can no longer be used. In order to use the remote control, you must keep the main ON/OFF switch in the OFF.
2. Display ON/OFF Dial: There is a flame icon directly below this dial and it is the knob at. After you turn the Main Power switch to the ON position, turn the Display Dial to desired setting. Both the logset and the flame will light up inside the fireplace
4
www.desatech.com
3. Heater Switch and Control Dial: The heater switch has a sun directly below it. To turn the heater on, flip the Heater Switch to ON position (the "|" indicates ON and "O" indicates OFF). The Control Knob has a thermometer below it. Turn the dial clockwise past the number 8. You should hear a small clicking sound indicat ing the heater has started and heat will emit through vents located at the bottom of the unit. To turn off heater, turn the temperature dial counter clockwise past number 1 and flip the Heater Switch to OFF position. Heat will stop coming out of the vent.
To increase the desired temperature, turn
the temperature dial clockwise towards Number 8.
To decrease the desired temperature, turn the
temperature dial counter clockwise towards number 1. The heater has a built-in thermo stat so it will shut off automatically once the set temperature is reached. It will also turn on automatically if the room temperature drops below the set temperature on the dial.
Note: When the heater is turned on for the
first time, it may release a slight, harmless odor. This odor is a normal occurrence caused by the initial heating of the internal heating elements and should not occur again.
4. Flame Control Dial: This dial controls the intensity of the flame.
Main Power SwitchFlame Control Dial
Heater Switch
Display Dial
Figure 3 - Electric Stove Control Panel
Heat Control Dial
OPERATING BY REMOTE CONTROL
1. Plug in your electric fireplace and it will beep once. This means you have power and your remote is ready to operate your electric fireplace.
IMPORTANT: To control the electric fireplace by remote, the Main ON/OFF power switch on the fireplace must be in the OFF position; the remote control will NOT work if the manual ON/OFF switch is in the ON position.
117190-01A
-
-
Loading...
+ 8 hidden pages