WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing
property damage, personal injury, or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call the
fire department.
— Installation and service must be performed by a quali-
fied installer, service agency, or the gas supplier.
Shown with optional hearth
base accessory.
WARNING: Improper installation,
adjustment, alteration, service, or
maintenance can cause injury or
property damage. Refer to this
manual for correct installation and
operational procedures. For assistance or additional information consult a qualified installer, service
agency, or the gas supplier.
WARNING: This is an unvented gasfired heater. It uses air (oxygen)
from the room in which it is installed. Provisions for adequate
combustion and ventilation air must
be provided. Refer to
bustion and Ventilation
Air for Com-
section on
page 5 of this manual.
This appliance may be installed in an aftermarket,* permanently located, manufactured
(mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance
is not convertible for use with other gases.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
Save this manual for future reference.
Save this manual for future reference.
TABLE OF CONTENTS
SAFETY INFORMATION
2
TABLE OF CONTENTS
SAFETY INFORMATION ............................................................ 2
IMPORTANT: Read this owner’s manual carefully and
completely before trying to assemble, operate, or service
this fireplace. Improper use of this fireplace can cause
serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.
DANGER: Carbon monoxide poisoning may lead
to death!
Carbon Monoxide Poisoning:Early signs of carbon monoxide
poisoning resemble the flu, with headaches, dizziness, or nausea. If
you have these signs, the fireplace may not be working properly.
Get fresh air at once! Have fireplace serviced. Some people are
more affected by carbon monoxide than others. These include
pregnant women, people with heart or lung disease or anemia, those
under the influence of alcohol, and those at high altitudes.
Natural and Propane/LP Gas: Natural and Propane/LP gases are
odorless. An odor-making agent is added to these gases. The odor
helps you detect a gas leak. However, the odor added to the gas can
fade. Gas may be present even though no odor exists.
Make certain you read and understand all warnings. Keep this
manual for reference. It is your guide to safe and proper operation
of this fireplace.
WARNING: Do not use a blower insert, heat
exchanger insert, or other accessory not approved
for use with this fireplace.
Due to high temperatures, the appliance should be
located out of traffic and away from furniture and
draperies.
Do not place clothing or other flammable material on
or near the appliance. Never place any objects on the
heater.
Fireplace front and screen become very hot when
running fireplace. Keep children and adults away
from hot surfaces to avoid burns or clothing ignition.
Fireplace will remain hot for a time after shutdown.
Allow surfaces to cool before touching.
Carefully supervise young children when they are in
the room with fireplace. When using the hand-held
remote accessory, keep selector switch in the OFF
position to prevent children from turning on burners
with remote.
WARNING: Any change to this heater or its
controls can be dangerous.
WARNING: Do not allow fans to blow directly into
the fireplace. Avoid any drafts that alter burner flame
patterns. Ceiling fans can create drafts that alter
burner flame patterns. Altered burner patterns can
cause sooting.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
You must operate this fireplace with the fireplace
screen and hood in place. Make sure fireplace screen
and hood are in place before running fireplace.
Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors
and liquids.
108117-01G
SAFETY INFORMATION
Continued
SAFETY INFORMATION
PRODUCT IDENTIFICATION
3
3
1.This appliance is only for use with the type of gas indicated on
the rating plate. This appliance is not convertible for use with
other gases.
2.Do not place propane/LP supply tank(s) inside any structure.
Locate propane/LP supply tank(s) outdoors.
3.If you smell gas
• shut off gas supply
• do not try to light any appliance
•
do not touch any electrical switch; do not use any phone in
your building
• immediately call your gas supplier from a neighbor’ s phone.
Follow the gas supplier’s instructions
• if you cannot reach your gas supplier , call the fire department
4.This fireplace shall not be installed in a bedroom or bathroom.
5.Do not use this fireplace as a wood-burning fireplace. Use only
the logs provided with the fireplace.
6.Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can cause sooting. Do not add lava rock around base. Rock and debris could
fall into the control area of fireplace.
7.To prevent the creation of soot, follow the instructions in Clean-ing and Maintenance, page 28.
8.Before using furniture polish, wax, carpet cleaner, or similar
products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or
on adjacent walls or furniture.
9.This fireplace needs fresh air ventilation to run properly . This
fireplace has an Oxygen Depletion Sensing (ODS) safety
shutoff system. The ODS shuts down the fireplace if not enough
fresh air is available. See Air for Combustion and Ventilation,
pages 5 through 7. If fireplace keeps shutting off, see Trouble-shooting, pages 29 through 31.
10. Do not run fireplace
• where flammable liquids or vapors are used or stored
• under dusty conditions
11. Do not use this fireplace to cook food or burn paper or other
objects.
12. Do not use fireplace if any part has been exposed to or under
water. Immediately call a qualified service technician to inspect the fireplace and to replace any part of the control system and any gas control which has been under water.
13. Do not operate fireplace if any log is broken. Do not operate
fireplace if a log is chipped (dime-sized or larger).
14. Turn fireplace off and let cool before servicing. Only a qualified service person should service and repair fireplace.
15. Operating fireplace above elevations of 4,500 feet could cause
pilot outage.
16. To prevent performance problems with propane/LP units, do
not use propane/LP fuel tanks of less than 100 lb. capacity.
17. Provide adequate clearances around air openings.
Install and use fireplace with care. Follow all local codes. In the
absence of local codes, use the latest edition of The National Fuel GasCode, ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
UNPACKING
CAUTION: Do not remove the data plates attached
to the heater base assembly. The data plates contain
important warranty and safety information.
1.With utility knife, cut the carton all the way around above the
staples on the bottom tray. Lift the carton off the heater. Remove packing.
the right hand side of the heater front. Lift the heater off the
bottom tray.
2.Locate two screws above top corners of the fireplace screen.
Remove and discard these screws. Lift fireplace screen up and
pull out to remove.
3.Remove protective packaging applied to logs, log base assembly, and fireplace.
4.Remove fireplace hood from carton insert.
5.Check all items for any shipping damage. If damaged, promptly
inform dealer where you bought fireplace.
Note:
The hood is located in the packing on
PRODUCT FEATURES
OPERATION
This vent-free fireplace is clean burning. It requires no outside
venting. There is no heat loss out a vent or up a chimney. Heat is
generated by both realistic flames and glowing embers. When used
without the optional blower, the fireplace requires no electricity
making it ideal for emergency backup heat.
SAFETY DEVICE
This fireplace has a pilot with an Oxygen Depletion Sensing (ODS)
safety shutoff system. The ODS/pilot is a required feature for ventfree room heaters. The ODS/pilot system shuts off the fireplace if
there is not enough fresh air.
PIEZO IGNITION SYSTEM
This fireplace has a piezo ignitor. This system requires no matches,
batteries, or other sources to light fireplace.
WIRELESS REMOTE CONTROL
This fireplace features an infrared wireless remote control. This
control system can be used to automatically light the pilot and adjust
the burner flame height at the push of a button.
WIRED WALL-MOUNTED REMOTE CONTROL
This fireplace features a two-button wall switch and wall plate with
glowing LED’s. The wall switch performs the same functions as the
wireless hand-held remote control with the added feature of LED’s
for visual feedback of operation and status.
OPTIONAL BLOWER ASSEMBLY
ACCESSORY
This fireplace accepts an optional blower assembly (not included).
The GA3650T/GA3700T Series blower operates thermostatically
and features a variable speed control. The GA3700/GA3750 Series
operates manually and also features a variable speed control. The
blower circulates heated air from the fireplace into the room. Use of
blower is optional. See Accessories, pages 42 and 43.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
108117-01G
AIR FOR COMBUSTION AND
VENTILATION
AIR FOR COMBUSTION AND VENTILATION
Providing Adequate Ventilation
5
5
WARNING: This heater shall not be installed in a
confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuelburning appliances in your home.
Today’s homes are built more energy efficient than ever. New
materials, increased insulation, and new construction methods help
reduce heat loss in homes. Home owners weather strip and caulk
around windows and doors to keep the cold air out and the warm air
in. During heating months, home owners want their homes as
airtight as possible.
While it is good to make your home energy efficient, your home
needs to breathe. Fresh air must enter your home. All fuel-burning
appliances need fresh air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances
draw air from the house to operate. You must provide adequate fresh
air for these appliances. This will insure proper venting of vented
fuel-burning appliances.
PROVIDING ADEQUATE VENTILATION
The following are excerpts from National Fuel Gas Code, ANSI
Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three following ventilation
classifications:
1. Unusually Tight Construction
2. Unconfined Space
3. Confined Space
The information on pages 5 through 7 will help you classify your
space and provide adequate ventilation.
Unusually tight construction is defined as construction
where:
a.walls and ceilings e xposed to the outside atmosphere
have a continuous water vapor retar der with a rating
of one perm (6 x 10
openings gasketed or sealed
b. weather stripping has been added on openable win-
dows and doors
c. caulking or sealants are applied to areas such as
joints around window and door frames, between sole
plates and floors, between wall-ceiling joints, between
wall panels, at penetrations for plumbing, electrical,
and gas lines, and at other openings.
If your home meets all of the three criteria above, you
must provide additional fresh air. See
From Outdoors
If your home does not meet all of the three criteria above,
proceed to
cation
on page 6.
, page 7
Determining Fresh-Air Flow for Fireplace Lo-
-11
kg per pa-sec-m2) or less with
and
and
Ventilation Air
.
Confined Space and Unconfined Space
The National Fuel Gas Code, ANSI Z223.1/NFPA 54 defines a
confined space as a space whose volume is less than 50 cubic feet
per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating
of all appliances installed in that space and an unconfined space as
a space whose volume is not less than 50 cubic feet per 1,000 Btu per
hour (4.8 m3 per kw) of the aggregate input rating of all appliances
installed in that space. Rooms communicating directly with the
space in which the appliances are installed*, through openings not
furnished with doors, are considered a part of the unconfined space.
* Adjoining rooms are communicating only if there are doorless
passageways or ventilation grills between them.
Unusually Tight Construction
The air that leaks around doors and windows may provide enough
fresh air for combustion and ventilation. However, in buildings of
unusually tight construction, you must provide additional fresh air.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
108117-01G
AIR FOR COMBUSTION AND VENTILATION
6
Determining Fresh-Air Flow For Heater Location
Ventilation Air
AIR FOR COMBUSTION AND
VENTILATION
Continued
DETERMINING FRESH-AIR FLOW FOR
HEATER LOCATION
Determining if You Have a Confined or
Unconfined Space
Use this work sheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install heater plus any adjoining
rooms with doorless passageways or ventilation grills between the rooms.
1.Determine the volume of the space (length x width x height).
Length x Width x Height =___________ cu. ft. (volume of space)
Example:
height) = 3168 cu. ft. (volume of space)
If additional ventilation to adjoining room is supplied with grills or open-
ings, add the volume of these rooms to the total volume of the space.
2.Multiply the space volume by 20 to determine the maximum Btu/Hr
the space can support.
__________ (volume of space) x 20 = (Maximum Btu/Hr the space
Example:
Btu/Hr the space can support)
3.Add the Btu/Hr of all fuel burning appliances in the space.
* Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.
4.Compare the maximum Btu/Hr the space can support with the actual
amount of Btu/Hr used.
__________________ Btu/Hr (maximum the space can support)
__________________ Btu/Hr (actual amount of Btu/Hr used)
Example:
The space in the above example is a confined space because the actual Btu/Hr
used is more than the maximum Btu/Hr the space can support. You must
provide additional fresh air. Your options are as follows:
Space size 20 ft. (length) x 18 ft. (width) x 8 ft. (ceiling
can support)
3168 cu. ft. (volume of space) x 20 = 63,360 (maximum
Vent-free heater_____________ Btu/Hr
Gas water heater*_____________ Btu/Hr
Gas furnace_____________ Btu/Hr
Vented gas heater_____________ Btu/Hr
Gas fireplace logs_____________ Btu/Hr
Other gas appliances* + _____________ Btu/Hr
Total = _____________ Btu/Hr
Example:
Gas water heater_____________ Btu/Hr
Vent-free heater+ _____________ Btu/Hr
Total= _____________ Btu/Hr
63,360 Btu/Hr (maximum the space can support)
73,000 Btu/Hr (actual amount of Btu/Hr used)
40,000
33,000
73,000
A. Rework worksheet, adding the space of an adjoining room. If the
extra space provides an unconfined space, remove door to adjoining
room or add ventilation grills between rooms. See V entilation Air Fr omInside Building.
B. Vent room directly to the outdoors. See Ventilation Air From Out-
doors, page 7.
C.Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can
support, the space is an unconfined space. You will need no additional fresh
air ventilation.
WARNING: If the area in which the heater may be
operated is smaller than that defined as an unconfined space or if the building is of unusually tight
construction, provide adequate combustion and ventilation air by one of the methods described in the
National Fuel Gas Code, ANSI Z223.1/NFPA 54 Section 5.3
or applicable local codes
.
VENTILATION AIR
Ventilation Air From Inside Building
This fresh air would come from an adjoining unconfined space.
When ventilating to an adjoining unconfined space, you must
provide two permanent openings: one within 12" of the ceiling and
one within 12" of the floor on the wall connecting the two spaces
(see options 1 and 2, Figure 3). You can also remove door into
adjoining room (see option 3, Figure 3). Follow the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion
and Ventilation for required size of ventilation grills or ducts.
12"
Ventilation
Grills
Into Adjoining
Room,
Option 1
Or
Remove
Door into
Adjoining
Room,
Option
3
Ventilation Grills
Into Adjoining Room,
Option 2
12"
Figure 3 - Ventilation Air from Inside Building (EFP33PR Shown)
For more information, visit www.desatech.com
For more information, visit www.desatech.com
108117-01G
AIR FOR COMBUSTION AND VENTILATION
Ventilation Air (Cont.)
INSTALLATION
7
7
AIR FOR COMBUSTION AND
VENTILATION
Continued
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or ducts. You must
provide two permanent openings: one within 12" of the ceiling and
one within 12" of the floor. Connect these items directly to the
outdoors or spaces open to the outdoors. These spaces include attics
and crawl spaces. Follow the National Fuel Gas Code, ANSI
Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation
for required size of ventilation grills or ducts.
IMPORTANT:
if attic has a thermostat-controlled power vent. Heated air entering the
attic will activate the power vent.
Outlet
Air
Inlet
Air
Figure 4 - Ventilation Air from Outdoors (EFP33PR Shown)
Do not provide openings for inlet or outlet air into attic
Outlet
Air
Inlet Air
Ventilated
Attic
To Attic
To
Crawl
Space
Ventilated
Crawl Space
INSTALLATION
NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary
heating system. Do not install this heater as your
primary heat source. If you have a central heating
system, you may run system’s circulating blower
while using heater. This will help circulate the heat
throughout the house. In the event of a power outage,
you can use this heater as your primary heat source.
WARNING: A qualified service person must in-
stall fireplace. Follow all local codes.
WARNING: Never install the fireplace
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture, clothing, or other flam-
mable objects are less than 42 inches from the
front, top, or sides of the fireplace
• in high traffic areas
• in windy or drafty areas
CAUTION: This fireplace creates warm air currents. These currents move heat to wall surfaces next
to fireplace. Installing fireplace next to vinyl or cloth
wall coverings or operating fireplace where impurities (such as, but not limited to, tobacco smoke,
aromatic candles, cleaning fluids, oil or kerosene
lamps, etc.) in the air exist, may discolor walls or
cause odors.
Note:
Your fireplace is designed to be used in zero clearance
installations. Wall or framing material can be placed directly against
any exterior surface on the rear, sides, or top of your fireplace,
except where standoff spacers are integrally attached. If standoff
spacers are attached to your fireplace, these spacers can be placed
directly against wall or framing materials.
Use the dimensions shown for rough openings to create the easiest
installation (see Built-In Fireplace Installation, pages 19 and 20).
IMPORTANT:
this is beneficial, installing fireplace in rooms without enough
ventilation air may cause mildew to form from too much moisture.
See Air for Combustion and Ventilation, pages 5 through 7.
IMPORTANT:
level, log set will not work properly.
Vent-free heaters add moisture to the air. Although
Make sure the fireplace is level. If fireplace is not
108117-01G
For more information, visit www.desatech.com
For more information, visit www.desatech.com
INSTALLATION
8
Check Gas Type
Electrical Hookup
Installation Clearances
Installation Sequence
Removing Fireplace Screen And Floor Assembly
INSTALLATION
Continued
CHECK GAS TYPE
Use the correct gas type (natural or propane/LP) for your unit. If
your gas supply is not correct, do not install fireplace. Call dealer
where you bought fireplace for proper type fireplace.
ELECTRICAL HOOKUP
This fireplace normally operates under 120 VAC/60 Hz line voltage. The electrical cord supplied with your fireplace is five feet in
length. You must locate fireplace within reach of a 120 volt
grounded electrical outlet. If not, you must install an electrical outlet
within reach of the fireplace power cord. The GA3555 outlet
accessory may be used for built-in applications.
INSTALLATION CLEARANCES
WARNING: Maintain the minimum clearances. If
you can, provide greater clearances from floor, ceiling, and adjoining wall.
Carefully follow the instructions below. This will ensure safe
installation.
Minimum Clearances For Side Combustible
Material, Side Wall, and Ceiling
A. Clearances from the side of the fireplace cabinet to any com-
bustible material and wall should follow diagram in Figure 5.
Example:
combustible material and protrudes 3 1/2" from the wall. This
combustible material must be 4" from the side of the fireplace
cabinet (see Figure 5).
B. Clearances from the top of the fireplace opening to the ceiling
should not be less than 42 inches.
The face of a mantel, bookshelf, etc. is made of
Example
INSTALLATION SEQUENCE
After unpacking fireplace (see Unpacking, page 4), we suggest that
you install your fireplace system in the following sequence:
1.Removal of fireplace floor assembly (required)
2.Electrical connections for power cord (required)
3.Relocating wall switch (optional)
4.Installing blower accessory (optional)
5.Connecting fireplace to gas supply (required)
6.Checking gas connections (required)
7.Firebox installation, conventional or built-in (required)
8.Installing brass perimeter trim (optional)
9.Installing fireplace hood (required)
10. Installing logs (required)
11. Installing fireplace screen (required)
Use the following instructions to complete each step.
REMOVING FIREPLACE SCREEN AND
FLOOR ASSEMBLY
NOTICE: Shutoff gas supply and disconnect heater
from gas supply if installing blower into previously
installed fireplace. Contact a qualified service person
to do this.
1.Remove fireplace screen. Remove two screws that hold fireplace screen in place for shipping. These screws are located
near top of screen. Discard screws. Lift fireplace screen up
and pull out to remove.
2.If logs are installed, carefully remove the logs and set aside,
noting the properly mounted location of each.
3.Remove screws that attach fireplace floor assembly to fireplace. Open lower louver door. Carefully lift up fireplace floor
assembly and remove from fireplace, taking care to pull flexible gas line through the access holes (see Figure 6, page 9).
Note:
Be careful of all wires on underside of log base.
*
*Minimum 16 inches from Side Wall
Figure 5 - Minimum Clearance for Combustible to Wall
For more information, visit www.desatech.com
For more information, visit www.desatech.com
CAUTION: Do not pick up fireplace floor assembly
by burners. This could damage burners. Only handle
base by grates.
108117-01G
INSTALLATION
Continued
INSTALLATION
Removing Fireplace Screen And Floor Assembly (Cont.)
This fireplace operates on 120 VAC, 60 Hz power. An electrical
power cord is supplied with this unit.
For Mantel Installation
1.Determine from which side of the fireplace the power cord will
exit. Locate the 1.5" diameter hole near the center of floor support bracket on appropriate side of lower cavity (see Figure 7).
2.Locate power cord. Remove wire tie or tape holding plug end
of power cord.
3.Power cord has 2 plastic hole bushings threaded onto it. Route
cord's 3-prong plug through the 1.5" diameter hole in appropriate floor support bracket.
4.Push first plastic bushing completely through hole. Squeeze
bushing as needed to do this.
5.Install the second plastic bushing into the hole in the floor support bracket by snapping into place.
6.Route the 3-prong plug through the 1.5" hole in fireplace
outer casing.
7.Install the first plastic bushing into this hole by snapping into place.
8.After you have connected to gas supply and checked your gas
connections (see pages 15 through 18), plug power cord into
any convenient 3-prong grounded wall receptacle near fireplace.
For Recessed Installation
If an outlet is not installed in fireplace, install model GA3555 Outlet Kit with Cover. This kit will supply a convenient 3-prong
grounded electrical outlet for power. Refer to installation manual
provided with this optional accessory for instructions on wiring.
Note:
A qualified installer must make all electrical connections.
Hole in Floor
Support Bracket
Bushings
Figure 7 - Routing Power Cord
Hole in Outer
Casing
Power Cord
RELOCATING WALL SWITCH
Note:
The decorative wall switch plate supplied is white. The wall
switch plate may be painted to match your decor.
The push-button switch and decorative wall plate assembly sup-
plied with your fireplace is pre-mounted at the factory in the lower
cavity of the fireplace. You may relocate this switch/plate assembly
to a more convenient location such as the side of your mantel or
directly onto the wall near the fireplace. To mount the wall switch/
plate assembly, you must first cut openings in the mantel or wall
where the switch will be located.
Note:
If you choose to relocate the wall switch, do so before final
installation into a mantel or recessing into a wall. If you are
installing an optional blower accessory, install it at the same time
you relocate the wall switch.
CAUTION: The wall switch must never be mounted
directly above the fireplace where heat may damage
it. If you relocate wall switch from lower fireplace
cavity, it must be mounted either on side wall of
mantel or on wall to side of fireplace.
For Recessed Installation
If fireplace is to be recessed into a wall (see Built-In Fireplace
Installation, pages 19 and 20), we recommend mounting wall
switch to left side of fireplace. The wall switch should be mounted
approximately 12" from left edge of fireplace, and less than 60"
from the floor.
front of wall stud - there must be room behind wall board for wires
from switch. If you choose to locate wall switch to right side of
fireplace, the length of the cord restricts you to less than 6" from
right edge of fireplace and less than 48" from floor.
IMPORTANT:
Do not locate wall switch directly in
108117-01G
For more information, visit www.desatech.com
For more information, visit www.desatech.com
INSTALLATION
10
Relocating Wall Switch (Cont.)
INSTALLATION
Continued
For Mantel Installation
If fireplace is to be installed into a mantel, (see Conventional
Fireplace Installation, pages 18 and 19) the wall switch may be
mounted on either side of the mantel, facing to the side. Do not
locate wall switch anywhere on the front face of the mantel.
CAUTION: Be careful of gas lines and wiring when
moving floor.
1.Determine the new location for the wall switch. The wires attached to switch are six feet long.
2.Remove 2 screws securing plastic wall plate to bracket in fireplace lower cavity. Save screws.
3.Remove wire tie holding coiled wire attached to wall switch
(see Figure 8).
4.Remove wall switch/plate assembly from bracket.
5.Carefully pass wall plate and cord through large elongated hole
in rear of either left or right floor support bracket, depending on
desired location of switch. Pass wall plate and cord through 1.5"
diameter hole in side of fireplace outer casing (see Figure 9).
6.Pull wall plate and cord from fireplace making sure wall switch/
plate assembly will reach desired mounting location without
straining cord assembly.
If you are mounting wall switch to a wall, continue reading. If you
are mounting your wall switch to the side of the mantel, see page 11.
CAUTION: Do not apply excessive pull on cord.
Mounting Wall Switch to Wall for Recessed Fireplace
7.Create three openings on wall according to Template 1, page
45. This is best done by making a pattern to work with on your
wall. Carefully cut page 45/46 from manual and tape paper
template vertically onto wall at preferred location. Pierce the
paper at the centers of the 2 holes with a nail or sharp pencil,
leaving a mark on the wall. Do the same at centers of the four
circles near the corners of the rectangle.
8.Remove paper template from wall.
9.Drill 3/8" holes at each mark.
10. Using a straight edge and pencil, connect the outer edges of
the 4 holes for the rectangle (see Figure 10). This will give you
cutting lines for the rectangle you will cut in the wall.
11. Using a keyhole saw, hack saw blade, drill, file, or other suitable tool, carefully cut out the rectangular opening.
corners of the rectangle may be round.
IMPORTANT:
Note:
Do not
The
exceed the size of the rectangle on template.
12. From inside the recessed opening for the fireplace, carefully
pass switch/plate assembly through the rectangular opening to
the outside of the wall.
13. Using wall anchors supplied in hardware package, fold wall
anchor as shown in Figure 11.
14. Insert wall anchor, wings first, into hole. T ap anchor flush to wall.
15. For thin walls (1/2" or less), insert red key into wall anchor.
Push red key to “pop” open anchor wings. See Figure 12.
IMPORTANT:
Do not hammer key! For thick walls (over 1/2"
thick), do not pop open wings.
Burner
Outlet
Tube
Gas Control Valve
Figure 8 - Relocating Switch and Wall Plate
Hole in Outer
Casing
Wall Switch/Plate Assy
Figure 9 - Routing Wall Switch/Plate Through Fireplace for
Relocation
Wire Tie
For more information, visit www.desatech.com
For more information, visit www.desatech.com
Firebox
Bottom
Switch with
Wall Plate
Hole in
Floor
Support
Bracket
3/8" Diameter
2 Holes
Make Marks
at Centers
of Holes
Template
from This
Manual
Figure 10 - Using Template for Wall Switch Installation
Figure 11 - Folding Anchor
3/4"
4 3/4"
3 3/4"
3/8"
3/16"
Figure 12 - Popping Open Anchor
Wings for Thin Walls
Cutting
Lines
Tape
108117-01G
INSTALLATION
Continued
Relocating Wall Switch (Cont.)
INSTALLATION
Installing Variable Speed Blower Accessory
11
11
16. Position switch/plate assembly vertically over wall openings
with decal lettering upright (see Figure 13).
17. Insert mounting screws, removed in step 2 of Relocating WallSwitch on pages 9 and 10, through holes in wall plate and into
wall anchors.
18. Tighten screws until wall plate is firmly attached to wall. Do
not overtighten.
Opening in
Wall or
Mantel Wall
Wall Plate/
Switch
Screws
Figure 13 - Securing Wall Switch
Mounting Wall Switch to Side of Mantel
7.Create three openings in the mantel wall according to Template 2, page 45. This is best done by making a pattern to work
with on the mantel. Carefully cut page 45/46 from manual and
tape paper template vertically onto mantel wall at preferred
location. Pierce the paper at the centers of the 2 holes with a
nail or sharp pencil, leaving a mark on the wall. Do the same
at centers of the four circles near the corners of the rectangle.
8.Remove paper template from mantel wall.
9.Drill 1/8" pilot holes at each mark for top and bottom screw
holes. Drill 3/8" holes at each mark for centers of four circles
near corners of rectangle.
10. Using a straight edge and pencil, connect the outer edges of the 4
holes for the rectangle (see Figure 10, page 10). This will give
you cutting lines for the rectangle you will cut in the mantel wall.
11. Using a keyhole saw, hack saw blade, drill, file, or other suitable tool, carefully cut out the rectangular opening.
corners of the rectangle may be round.
IMPORTANT:
Note:
Do not
The
exceed the size of the rectangle on template.
12. Carefully pass switch/plate assembly through rectangular opening from inside mantel (see Figure 13).
13. Position switch/plate assembly vertically over opening with
decal lettering upright. Make sure wires freely pass through
wall without binding. Align holes in wall plate with 1/8" pilot
holes in mantel wall.
14. Drive mounting screws, removed in step 2 of Relocating WallSwitch on pages 9 and 10, through wall plate holes and into
pilot holes in mantel wall.
15. Tighten screws until wall plate is firmly attached to mantel.
Do not overtighten.
INSTALLING VARIABLE SPEED BLOWER
ACCESSORY
NOTICE: Shut off gas supply and disconnect heater
from gas supply if installing blower into previously
installed fireplace. Contact a qualified service person
to do this.
1.If fireplace screen and floor are still installed, see Removing
Fireplace Scr een and Floor Assembly, page 8.
2.Attach the power cord to the blower motor by firmly pushing
the two female terminals at the end of the power cord onto the
two spade terminals on the blower motor.
3.Attach green ground wire from power cord to blower housing
using screw provided (see Figure 14). Tighten screws securely .
4.Place the blower against lower rear wall of firebox outer wrapper with the exhaust port directed upward. Align the holes in
top mounting tabs of blower with holes in wall of wrapper
(see Figure 14). Using 2 screws provided, mount blower and
tighten screws securely.
Blower
Lower Rear
Wall of
Firebox
Screws
Exhaust
Port
Top
Mounting
Screw
Green Ground Wire
Tab
108117-01G
Figure 14 - Mounting Blower to Firebox (VTGF33NR/VTGF33PR
Shown)
5.Be certain that all wire terminals are securely attached to terminals on blower motor and that the screw retaining the green
ground wire is tight.
6.Place control knob provided on plastic control shaft of speed
control.
7.Mount the speed control on the front leg of the left floor support bracket using 2 screws provided (see Figure 15).
8.Plug in blower power cord.
a. If your f ireplace system is installed as a freestanding unit
with an accessory mantel, determine whether the power
cord will exit the left side or the right side of the firebox.
Install 1 plastic bushing provided into the 1.5" hole in the
floor support bracket on the exit side (see Figure 16). Install
the second plastic bushing provided into the 1.5" hole in the
outer casing through which the power cord will exit. Route
power cord through both plastic bushings and plug the power
cord into a properly grounded 3-prong wall receptacle near
the firebox.
b.If your fireplace system installation is recessed and if an
outlet is not installed in your fireplace, you must install
the GA3555 Outlet kit with cover in your fireplace which
will supply a convenient 3-prong grounded electrical outlet
for your blower. Refer to the installation manual provided
with the model GA3555 accessory for instructions on wiring the duplex outlet.
Note:
A qualified installer must make all electrical connections.
9.Check to make sure that all electrical cords are completely
clear of the blower wheel and that there are no other foreign
objects in blower wheel. Turn blower on and check for operation. Turn blower off by rotating knob fully counterclockwise
before continuing.
10. Peel off backing paper and stick supplied wiring diagram decal near center of firebox bottom (Figure 17, page 13).
11. If gas connections have been made and checked, replace fireplace floor assembly. Feed flexible gas supply line into fireplace base area while replacing fireplace floor assembly. Make
sure the entire flexible gas line is in fireplace base area.
IMPORTANT:
Do not pick up fireplace floor assembly by
burners. This could damage burners. Only handle base by
grates.
Note:
Be careful of all wires and components on un-
derside of floor assembly.
12. Reattach fireplace floor assembly with screws removed in step
3 of Removing Fireplace Screen and Floor Assembly, page 8.
Note:
Discard the remaining hardware items. After assembly,
make sure all wires are completely clear of blower wheel.
13. Install logs (see Installing Logs, pages 21 through 23) and fire-
place screen (see Installing Screen, page 24).
WARNING: Failure to position the parts in accordance with supplied diagrams or failure to use only
parts specifically approved with this heater may result in damage or personal injury.
WARNING: A qualified service person must connect fireplace to gas supply. Follow all local codes.
CAUTION: Never touch the blower wheel while in
operation.
Left Floor
Support
Bracket
Screws
Speed
Control
Control
Control Knob
Figure 15 - Attaching Speed Control to Firebox (VTGF33NR/
VTGF33PR Shown)
Shaft
For more information, visit www.desatech.com
For more information, visit www.desatech.com
Right Floor
Support Bracket
Figure 16 - Installing Plastic Bushing for Power Cord (VTGF33NR/
VTGF33PR Shown)
Plastic
Bushing
108117-01G
INSTALLATION
Continued
e
l
h
r
b
c
e
t
a
i
i
w
r
r
w
o
o
a
l
t
S
V
o
B
n
M
a
F
n
O
k
c
a
l
e
t
f
B
i
k
f
c
h
O
a
l
W
k
B
c
a
l
B
k
c
a
5
l
e
1
t
B
i
.
1
/
h
n
C
0
.
e
W
1
e
A
.
r
1
V
G
Wiring
Diagram
WARNING: Never attempt to service heater while it is plugged in, operating, or hot. Burns and electrical shoc k could result. Only a qualified service person should service or repair heater.
If any of the original wire as supplied with the appliance must be replaced, it must be
replaced with 105°C wire or it’s equivalent.
WARNING: Label all wires prior to disconnection when servicing controls. Wiring error s can cause improper and dangerous operation. V erify proper
operation after servicing.
2.Using screw provided, attach green ground wire from speed
control cord to blower housing. Tighten screw securely (see
Figure 18).
3.Place the blower against lower rear wall of firebox outer wrapper with the exhaust port directed upward. Align the holes in
top mounting tabs of blower with holes in wall of wrapper
(see Figure 19, page 14). Using two #8 screws provided, mount
blower and tighten screws firmly.
4.Remove the three screws (do not discard) and cover plate from
center of firebox wrapper rear wall. Discard this cover plate
(see Figure 18).
5.Mount the supplied thermostatic switch and cover assembly
into firebox wrapper wall. Do this by feeding terminal ends of
wire harness into the hole. Allow wires to fall to bottom of
firebox cavity (see Figure 18).
6.Using three screws from step 7, attach switch and cover assembly to firebox wrapper rear wall. Tighten screws firmly
(see Figure 18).
7.Firmly attach red wire from the thermostatic switch and cover
assembly to either of the terminals on the blower motor (see
Figure 18).
8.Firmly attach black wire from speed control cord to blue wire
from thermostatic switch and cover assembly (see Figure 18).
9.Firmly attach white wire from speed control cord to remaining
terminal on blower motor (see Figure 18).
13
13
120 Vac. 60 Hz. . 78 Amps
DESA International, Bowling Green, KY
101584-05
Figure 17 - Location of Wiring Diagram Decal 3" from Blower
(VTGF33NR/VTGF33PR Shown)
Operating the Blower
Light your gas appliance with the blower off. After about 15
minutes, turn the blower on to deliver heated air at the top louvers.
The blower features a variable control which allows you to select the
speed you desire.
Note:
Periodically check the louvers of the fire-
box and remove any dust, dirt, or other obstructions.
INSTALLING THERMOSTATIC BLOWER
ACCESSORY
NOTICE: Shut off gas supply and disconnect heater
from gas supply if installing blower in previously
installed fireplace. Contact a qualified service person
to do this.
1.If fireplace screen and floor are still installed, see Removing
Fireplace Scr een and Floor Assembly, page 8.
Thermostatic Switch
and Cover Assembly
Blue
Black
Wire
Wire
Red
Wire
White
Wire
Speed
Control
Green
Wire
Figure 18 - Installing Switch and Cover Assembly, and Speed
Control (VTGF33NR/VTGF33PR Shown)
108117-01G
For more information, visit www.desatech.com
For more information, visit www.desatech.com
INSTALLATION
14
Installing Thermostatic Blower Accessory (Cont.)
INSTALLATION
Continued
10. Place control knob provided on plastic control shaft of speed
control (see Figure 20).
11. Mount the speed control onto the front leg of the left floor
support bracket using 2 screws provided (see Figure 20).
WARNING: Failure to connect all wires properly
as indicated may cause electrical short circuit or
personal injury. A qualified electrician should check
that all connections are made properly.
12. Plug in blower power cord.
a. If your firebox is installed as a freestanding unit with an
accessory mantel, determine whether the power cord will
exit the left side or the right side of the firebox. Install one
plastic bushing provided into the 1
1
/2" hole in the floor support on the exit side. Install the second bushing provided into
the 1 1/2" hole in the outer casing through which the power
cord will exit (see Figures 21 and 22). Route power cord
through plastic bushings and plug the power cord into a properly grounded three-prong wall receptacle near the firebox.
b.If your fireplace system installation is recessed and if an
outlet is not installed in your fireplace, you must install
the GA3555 Outlet kit with cover in your fireplace which
will supply a convenient 3-prong grounded electrical outlet
for your blower. Refer to the installation manual provided
with the model GA3555 accessory for instructions on wiring the duplex outlet.
Note:
A qualified installer must make all electrical connections.
13. Check to make sure that the power cord and all wires are completely clear of the blower wheel and that there are no other
foreign objects in blower wheel.
CAUTION: Never touch the blower wheel while in
operation.
14. Peel off backing paper and stick supplied wiring diagram decal near center of firebox bottom (see Figure 23, page 15).
Floor
Support
Bracket
Speed
Control
Screws
Control Knob
Figure 20 - Attaching Speed Control (VTGF33NR/VTGF33PR
Shown)
Blower
Lower
Rear Wall
of Firebox
#8 Screws
Exhaust
Port
Top
Mounting
Tab
Figure 19 - Mounting Blower to Firebox (VTGF33NR/VTGF33PR
Shown)
For more information, visit www.desatech.com
For more information, visit www.desatech.com
Right Floor
Support Bracket
Figure 21 - Installing Plastic Bushing for Power Cord (Right Side
Exit Shown) (VTGF33NR/VTGF33PR Shown)
15. If gas connections have been made and checked, replace fireplace
floor assembly in fireplace. Feed flexible gas supply line into fireplace base area while replacing fireplace floor assembly. Make sure
the entire flexible gas line is in fireplace base area.
Do not pick up fireplace floor assembly by burners. This could
damage burners. Only handle base by grates.
all wires and components on underside of floor assembly.
16. Reattach fireplace floor assembly with screws removed in step
3 of Removing Fireplace Screen and Floor Assembly, page 8.
Note:
Discard the remaining hardware items. After assembly,
make sure all wires are completely clear of blower wheel.
17. Install logs (see Installing Logs, pages 21 through 23) and fire-
place screen (see Installing Screen, page 24).
WARNING: Failure to position the parts in accordance with supplied diagrams or failure to use only
parts specifically approved with this heater may result
in damage or personal injury.
WARNING: A qualified service person must connect fireplace to gas supply. Follow all local codes.
IMPORTANT:
Note:
Be careful of
Installing Thermostatic Blower Accessory (Cont.)
INSTALLATION
15
15
Installing Gas Piping to Fireplace Location
If any of the original wire as supplied with the appliance must be
replaced, it must be replaced with 105˚C wire or it's equivalent.
Operating the Blower
After final installation of your fireplace, light your gas appliance
with the blower off. After about 15 minutes, turn the blower on to
deliver heated air at the top louvers. The blower features a variable
control which allows you to select the speed you desire. In the OFF
position, the blower will not operate. In the ON position, the
blower will start when the thermostat senses a sufficient increase
in firebox temperature (approximately 10 to 20 minutes depending on heat setting).
Your gas logs and thermostat blower will not turn on and off at the
same time. The fireplace may run for several minutes before the
blower turns on. After the heater modulates to the pilot position, the
blower will continue to run. The blower will shut off after the
firebox temperature decreases.
It is safe to operate fireplace with blower turned off. However, the
blower helps distribute heated air from the fireplace.
Note:
Periodically check the louvers of the firebox and remove any
dust, dirt, or other obstructions.
le
r
b
ch
e
t
a
i
w
r
ri
w
o
o
a
l
t
S
V
o
B
n
M
a
F
n
O
k
c
a
l
e
f
B
it
k
f
c
h
O
la
W
k
B
c
la
B
k
c
la
15
te
B
i
.
/1
h
n
C
0
.
e
W
1
e
.A
r
1
V
G
Wiring
Diagram
WARNING: Never attempt to service heater while it is plugged in, operating, or hot. Burns and electrical shock could result. Only a qualified service person should service or repair heater.
If any of the original wire as supplied with the appliance must be replaced, it must be
replaced with 105°C wire or it’s equivalent.
WARNING: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify
proper operation after servicing.
Off
110/115
V.A.C.
Black
Green
White
120 Vac. 60 Hz. .90 Amps
DESA International, Bowling Green, KY
Variable
Fan Switch
1
Fan Switch
(N.O.)
Black
2
Blue
On
Blower
Motor
Red
INSTALLING GAS PIPING TO FIREPLACE
LOCATION
WARNING: A qualified service person must con-
nect fireplace to gas supply. Follow all local codes.
WARNING: For propane/LP units, never connect
fireplace directly to propane/LP supply. This fireplace requires an external regulator (not supplied).
Install the external regulator between the heater and
propane/LP supply.
WARNING: For natural gas units, never connect
fireplace to private (non-utility) gas wells. This gas is
commonly known as wellhead gas.
Figure 23 - Location of Wiring Diagram Decal 3" from Blower
(VTGF33NR/VTGF33PR Shown)
For more information, visit www.desatech.com
For more information, visit www.desatech.com
108117-01G