WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result
causing property damage, personal injury, or
loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of
this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed by
a qualified installer, service agency, or the gas
This appliance may be installed in an aftermarket,* permanently located, manufactured
(mobile) home, where not prohibited by local codes.
This appliance is only for use with type of gas indicated on the rating plate. This appliance
is not convertible for use with other gases.
WARNING: Improper installation, adjustment, alteration, service, or maintenance
can cause injury or property damage.
Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency,
or the gas supplier.
WARNING: This is an unvented gasfired heater. It uses air (oxygen) from the
room in which it is installed. Provisions
for adequate combustion and ventilation air must be provided. Refer to
Combustion and Ventilation
page 5 of this manual.
Air for
section on
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
Save this manual for future reference.
Save this manual for future reference.
TABLE OF CONTENTS
SAFETY INFORMATION
2
TABLE OF CONTENTS
SAFETY INFORMATION ............................................................ 2
LOCAL CODES........................................................................... 3
CLEANING AND MAINTENANCE ............................................ 19
SAFETY INFORMATION
WARNINGS
WARNING ICON G 001
WARNING: This product contains and/or generates
chemicals known to the State of California to cause
cancer or birth defects, or other reproductive harm.
IMPORTANT: Read this owner’s manual carefully
and completely before trying to assemble, operate,
or service this fireplace. Improper use of this fireplace can cause serious injury or death from burns,
fire, explosion, electrical shock, and carbon monoxide poisoning.
DANGER: Carbon monoxide poisoning may lead
to death!
Carbon Monoxide Poisoning: Early signs of carbon monoxide
poisoning resemble the flu, with headaches, dizziness, or nausea. If
you have these signs, the fireplace may not be working properly.
Get fresh air at once! Have fireplace serviced. Some people are
more affected by carbon monoxide than others. These include
pregnant women, people with heart or lung disease or anemia, those
under the influence of alcohol, and those at high altitudes.
Natural and Propane/LP Gas: Natural and propane/LP gases are
odorless. An odor-making agent is added to the gas. The odor helps
you detect a gas leak. However, the odor added to the gas can fade. Gas
may be present even though no odor exists.
Make certain you read and understand all warnings. Keep this
manual for reference. It is your guide to safe and proper operation
of this fireplace.
WARRANTY INFORMATION ...................................... Back Cover
WARNING: Do not allow fans to blow directly into
the fireplace. Avoid any drafts that alter burner flame
patterns. Ceiling fans can create drafts that alter
burner flame patterns. Altered burner patterns can
cause sooting.
WARNING: Do not use a blower insert, heat exchanger insert, or other accessory not approved for
use with this fireplace.
Due to high temperatures, the appliance should be
located out of traffic and away from furniture and
draperies.
Do not place clothing or other flammable material on
or near the appliance. Never place any objects on
the heater.
Fireplace front and screen becomes very hot when
running fireplace. Keep children and adults away
from hot surfaces to avoid burns or clothing ignition.
Fireplace will remain hot for a time after shutdown.
Allow surfaces to cool before touching.
Carefully supervise young children when they are in
same room with fireplace.
You must operate this fireplace with the fireplace
screen in place. Make sure fireplace screen is in place
before running fireplace.
WARNING: Any change to this fireplace or its
controls can be dangerous.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors
and liquids.
111044-01A
SAFETY INFORMATION
Continued
SAFETY INFORMATION
LOCAL CODES
PRODUCT IDENTIFICATION
3
3
1.This appliance is only for use with the type of gas indicated on
the rating plate. This appliance is not convertible for use with
other gases.
2.Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors (propane/LP units only).
3.If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not use any phone in
your building
• immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions
• if you cannot reach your gas supplier, call the fire department
4.This fireplace shall not be installed in a bedroom or bathroom.
5.Do not use this fireplace as a wood-burning fireplace. Use only
the logs provided with the fireplace.
6.Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can cause sooting. Do not add lava rock around base. Rock and debris could
fall into the control area of fireplace.
7.This fireplace is designed to be smokeless. If logs ever appear
to smoke, turn off fireplace and call a qualified service person.
Note:
During initial operation, slight smoking could occur due
to log curing and fireplace burning manufacturing residues.
8.To prevent the creation of soot, follow the instructions in Clean-ing and Maintenance, page 19.
9.Before using furniture polish, wax, carpet cleaner, or similar
products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or
on adjacent walls or furniture.
10. This fireplace needs fresh air ventilation to run properly . This
fireplace has an Oxygen Depletion Sensing (ODS) safety
shutoff system. The ODS shuts down the fireplace if not enough
fresh air is available. See Air for Combustion and Ventilation,
pages 5 through 7. If fireplace keeps shutting off, see Trouble-shooting, pages 20 through 22.
11. Do not run fireplace
• where flammable liquids or vapors are used or stored.
• under dusty conditions.
12. Do not use this fireplace to cook food or burn paper or
other objects.
13. Never place any objects in the fireplace or on logs.
14. Do not use fireplace if any part has been under water. Immediately call a qualified service technician to inspect the room
fireplace and to replace any part of the control system and any
gas control which has been under water.
15. Turn off and unplug fireplace and let cool before servicing. Only
a qualified service person should service and repair fireplace.
16. Operating fireplace above elevations of 4,500 feet could cause
pilot outage.
17. Do not operate fireplace if any log is broken. Do not operate
fireplace if a log is chipped (dime-sized or larger).
18. To prevent performance problems, do not use propane/LP fuel
tank of less than 100 lbs. capacity (propane/LP units only).
19. Provide adequate clearances around air openings.
LOCAL CODES
Install and use fireplace with care. Follow all local codes. In the
absence of local codes, use the latest edition of The National Fuel GasCode ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
PRODUCT IDENTIFICATION
Fireplace
Cabinet
Screen
Log Set
Control Knob
Ignitor Button
Figure 1 - Vent-Free Gas Compact Fireplace
111044-01A
For more information, visit www.desatech.com
For more information, visit www.desatech.com
PRODUCT FEATURES
4
UNPACKING
ASSEMBLY
Assembling Fireplace
PRODUCT FEATURES
SAFETY PILOT
This fireplace has a pilot with an Oxygen Depletion Sensing (ODS)
safety shutoff system. The ODS/pilot is a required feature for ventfree room fireplaces. The ODS/pilot shuts off the fireplace if there
is not enough fresh air.
PIEZO IGNITION SYSTEM
This fireplace has a piezo ignitor. This system requires no matches,
batteries, or other sources to light fireplace.
THERMOSTATIC HEAT CONTROL
This fireplace has a thermostat sensing bulb and a control valve. The
thermostat will automatically modulate the heat output to maintain
a consistent room temperature. This results in greater fireplace
comfort. This can also result in lower gas bills.
UNPACKING
1.Remove log box and fireplace from carton.
fireplace hood is inside the cardboard protective end wrap on
the left side of fireplace (as viewed from front). A decal is on
the outside of the cardboard end wrap stating hood is enclosed
(see Figure 2).
2.Remove hood from cardboard protective end wrap as shown
in Figure 2.
3.Remove all protective packaging applied to fireplace for shipment.
4.Make sure your fireplace includes one hardware packet.
5.Check fireplace for any shipping damage. If fireplace is damaged, promptly inform dealer where you bought fireplace.
IMPORTANT:
Hood Enclosed
Decal
THIS PACKAGE CONTAINS A
FIREPLACE HOOD. UNWRAP
CARTON AND REMOVE HOOD
BEFORE DISCARDING
PROTECTIVE PACKAGING.
IMPORTANT:
The
ASSEMBLY
WARNING: Always have branch support and
screen in place before operating fireplace. This prevents excessive temperatures on fireplace surfaces.
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts
specifically approved with this fireplace may result in
property damage or personal injury.
ASSEMBLING FIREPLACE
Tools Required:
• Phillips screwdriver
• 5/16" hex wrench
• slotted screwdriver
• scissors
Installing Log
1.Lift screen up and pull out to remove.
2.Cut two plastic straps to remove the log from the firebox cavity.
3.An optional blower is available. See Accessories, page 29. Install optional blower now . Follow installation instructions provided with blower.
4.Remove log packaging material and discard packaging. Gently
place log set on burner support (see Figure 3). The log should
fit flat against top of burner support and log locator tabs fit
into the slots under the log. Do not allow log to contact flame.
If flame contacts log, soot will be created.
5.Reattach screen by placing the notches in the screen frame
over the shoulder screws and pushing down.
Log
Shoulder
Screw
Burner Support with
Log Locator Tabs
2
1
Figure 2 - Removing Fireplace Hood
For more information, visit www.desatech.com
For more information, visit www.desatech.com
Cardboard Protective
Fireplace End Wrap
Hood
Screen
Branch Support
Figure 3 - Assembling Fireplace
111044-01A
ASSEMBLY
Continued
Assembling Fireplace (Cont.)
ASSEMBLY
AIR FOR COMBUSTION AND VENTILATION
Providing Adequate Ventilation
5
5
Assembling Hood
1.Locate four black phillips sheet metal screws from the hardware packet.
2.Rotate hood as shown in Figure 4. Make sure hood tabs
point toward fireplace.
3.Insert hood tabs between baffle and louvers (see Figure 4).
4.Gently rotate hood to upright position. Make sure hood tabs are
behind louvers and hood is resting on firebox top (see Figure 4).
5.Align screw holes on hood with screw holes on firebox top.
6.Insert screws as shown in Figure 4. Tighten screws firmly.
Hood Tabs
Hood
Louver
Hood Tab
Baffle
Sheet Metal
Screws
Firebox Top
Figure 4 - Assembling Hood
AIR FOR COMBUSTION AND
VENTILATION
WARNING: This heater shall not be installed in a
confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuelburning appliances in your home.
Today’s homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce
heat loss in homes. Home owners weather strip and caulk around
windows and doors to keep the cold air out and the warm air in. During
heating months, home owners want their homes as airtight as possible.
While it is good to make your home energy efficient, your home
needs to breathe. Fresh air must enter your home. All fuel-burning
appliances need fresh air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances
draw air from the house to operate. You must provide adequate fresh
air for these appliances. This will insure proper venting of vented
fuel-burning appliances.
PROVIDING ADEQUATE VENTILATION
The following are excerpts from National Fuel Gas Code, ANSI
Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three following ventilation
classifications:
1.Unusually Tight Construction
2.Unconfined Space
3.Confined Space
The information on pages 5 through 7 will help you classify your
space and provide adequate ventilation.
Unusually Tight Construction
The air that leaks around doors and windows may provide enough
fresh air for combustion and ventilation. However, in buildings of
unusually tight construction, you must provide additional fresh air.
Unusually tight construction is defined as construction
where:
a.walls and ceilings e xposed to the outside atmosphere
have a continuous water vapor retar der with a rating
of one perm (6 x 10
openings gasketed or sealed
b. weather stripping has been added on openable win-
dows and doors
c. caulking or sealants are applied to areas such as
joints around window and door frames, between sole
plates and floors, between wall-ceiling joints, between
wall panels, at penetrations f or plumbing, electrical,
and gas lines, and at other openings.
If your home meets all of the three criteria above, you
must provide additional fresh air. See
From Outdoors
If your home does not meet all of the three criteria above,
proceed to
Location
, page 6.
, page 7
Determining Fresh-Air Flow For Fireplace
-11
kg per pa-sec-m2) or less with
and
and
Ventilation Air
.
111044-01A
For more information, visit www.desatech.com
For more information, visit www.desatech.com
AIR FOR COMBUSTION AND VENTILATION
6
Providing Adequate Ventilation (Cont.)
Determining Fresh-Air Flow for Heater Location
AIR FOR COMBUSTION AND
VENTILATION
Continued
Confined and Unconfined Space
The National Fuel Gas Code, ANSI Z223.1/NFPA 54 defines a
confined space as a space whose volume is less than 50 cubic feet
per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating
of all appliances installed in that space and an unconfined space as
a space whose volume is not less than 50 cubic feet per 1,000 Btu per
hour (4.8 m3 per kw) of the aggregate input rating of all appliances
installed in that space. Rooms communicating directly with the
space in which the appliances are installed*, through openings not
furnished with doors, are considered a part of the unconfined space.
* Adjoining rooms are communicating only if there are doorless
passageways or ventilation grills between them.
DETERMINING FRESH-AIR FLOW FOR
HEATER LOCATION
Determining if You Have a Confined or
Unconfined Space
Use this work sheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install heater plus any adjoining
rooms with doorless passageways or ventilation grills between the rooms.
1.Determine the volume of the space (length x width x height).
Length x Width x Height =___________ cu. ft. (volume of space)
Example:
height) = 2560 cu. ft. (volume of space)
If additional ventilation to adjoining room is supplied with grills or open-
ings, add the volume of these rooms to the total volume of the space.
2.Multiply the space volume by 20 to determine the maximum Btu/Hr
the space can support.
__________ (volume of space) x 20 = (Maximum Btu/Hr the space
Example:
Btu/Hr the space can support)
Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling
can support)
2560 cu. ft. (volume of space) x 20 = 51,200 (maximum
3.Add the Btu/Hr of all fuel burning appliances in the space.
Vent-free heater_____________ Btu/Hr
Gas water heater*_____________ Btu/Hr
Gas furnace_____________ Btu/Hr
Vented gas heater_____________ Btu/Hr
Gas fireplace logs_____________ Btu/Hr
Other gas appliances* + _____________ Btu/Hr
Total = _____________ Btu/Hr
* Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.
Example:
Gas water heater_____________ Btu/Hr
Vent-free heater+ _____________ Btu/Hr
Total= _____________ Btu/Hr
4.Compare the maximum Btu/Hr the space can support with the actual
amount of Btu/Hr used.
__________________ Btu/Hr (maximum the space can support)
__________________ Btu/Hr (actual amount of Btu/Hr used)
Example:
The space in the above example is a confined space because the actual Btu/
Hr used is more than the maximum Btu/Hr the space can support. You must
provide additional fresh air. Your options are as follows:
A. Rework worksheet, adding the space of an adjoining room. If the
extra space provides an unconfined space, remove door to adjoining
room or add ventilation grills between rooms. See V entilation Air Fr omInside Building, page 7.
B. Vent room directly to the outdoors. See Ventilation Air From Out-
doors, page 7.
C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room
unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can
support, the space is an unconfined space. You will need no additional fresh
air ventilation.
51,200 Btu/Hr (maximum the space can support)
56,000 Btu/Hr (actual amount of Btu/Hr used)
30,000
26,000
56,000
WARNING: If the area in which the heater may be
operated is smaller than that defined as an unconfined space or if the building is of unusually tight
construction, provide adequate combustion and ventilation air by one of the methods described in the
National Fuel Gas Code, ANSI Z223.1/NFPA 54 Section 5.3
For more information, visit www.desatech.com
For more information, visit www.desatech.com
or applicable local codes
.
111044-01A
AIR FOR COMBUSTION AND
VENTILATION
Continued
VENTILATION AIR
AIR FOR COMBUSTION AND VENTILATION
Ventilation Air
INSTALLATION
Check Gas Type
7
7
Ventilation Air From Inside Building
This fresh air would come from an adjoining unconfined space.
When ventilating to an adjoining unconfined space, you must
provide two permanent openings: one within 12" of the ceiling and
one within 12" of the floor on the wall connecting the two spaces
(see options 1 and 2, Figure 5). You can also remove door into
adjoining room (see option 3, Figure 5). Follow the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion
and Ventilation for required size of ventilation grills or ducts.
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or ducts. You must
provide two permanent openings: one within 12" of the ceiling and
one within 12" of the floor. Connect these items directly to the
outdoors or spaces open to the outdoors. These spaces include attics
and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for
required size of ventilation grills or ducts.
IMPORTANT:
if attic has a thermostat-controlled power vent. Heated air entering the
attic will activate the power vent.
Ventilation
Grills
into Adjoining
Room,
Option 1
Do not provide openings for inlet or outlet air into attic
12"
Ventilation Grills
Into Adjoining Room,
Or
Remove
Door into
Adjoining
Room,
Option 3
12"
Option 2
Outlet
Air
Outlet
Air
Inlet
Air
Inlet Air
Figure 6 - Ventilation Air from Outdoors Shown with Optional
Mantel
Ventilated
Attic
To Attic
To
Crawl
Space
Ventilated
Crawl Space
INSTALLATION
NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary
heating system. Do not install this heater as your
primary heat source. If you have a central heating
system, you may run system’s circulating blower
while using heater. This will help circulate the heat
throughout the house. In the event of a power outage,
you can use this heater as your primary heat source.
WARNING: A qualified service person must in-
stall fireplace. Follow all local codes.
Note:
Your Comfort Glow fireplace is designed to be used in zero
clearance installations. Wall or framing material can be placed
directly against any exterior surface of your fireplace, except where
standoff spacers are integrally attached. If standoff spacers are
attached to your fireplace, these spacers can be placed directly
against wall or framing materials.
Use the dimensions shown for rough openings to create the easiest
installation (see Built-In Fireplace Installation, page 9)
Figure 5 - Ventilation Air from Inside Building Shown with
Optional Mantel
For more information, visit www.desatech.com
For more information, visit www.desatech.com
111044-01A
CHECK GAS TYPE
Use the correct gas type (natural or propane/LP) for your unit. If
your gas supply is not correct, do not install fireplace. Call dealer
where you bought fireplace for proper type fireplace.
INSTALLATION
8
Installation Items
Locating Fireplace
INSTALLATION
Continued
INSTALLATION ITEMS
Before installing fireplace, make sure you have the items listed below.
• external regulator - propane/LP only (supplied by installer)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection *
• ground joint union
• sediment trap
• tee joint
• pipe wrench
* A CSA design-certified equipment shutoff valve with 1/8" NPT tap
is an acceptable alternative to test gauge connection. Purchase the
optional CSA design-certified equipment shutoff valve from your
dealer. See Accessories, page 29.
Note:
If desired, purchase a four-sided brass trim kit for built-in
installations. See Accessories, page 29.
LOCATING FIREPLACE
WARNING: Maintain the minimum clearances
shown in Figures 7 and 8. If you can, provide greater
clearances from floor, ceiling, and joining wall.
You can recess firebox into the wall. You can also position fireplace
in the optional cabinet or corner mantels.
optional cabinet or corner mantels specified in this manual. Purchase
the optional mantel from your dealer (see Accessories, page 29).
WARNING: Never install the fireplace
• in a bedroom or a bathroom
• in a recreational vehicle
• where curtains, furniture, clothing, or other flam-
mable objects are less than 36 inches from the
front, top, or sides of the fireplace
• as a fireplace insert
• in high traffic areas
• in windy or drafty areas
IMPORTANT:
Only use
I
MPORTANT:
Vent-free fireplaces add moisture to the air. Although
this is beneficial, installing fireplace in rooms without enough ventilation air may cause mildew to form from too much moisture. See Airfor Combustion and Ventilation, pages 5 through 7.
Note:
When installing fireplace directly on carpeting, tile or other
combustible material, other than wood flooring, the fireplace shall
be installed on a metal or wood panel extending the full width and
depth of the fireplace
CAUTION: If you install the fireplace in a home garage
• fireplace pilot and burner must be at least 18 inches
above floor.
• locate fireplace where moving vehicle will not hit it.
CEILING
36" Minimum
6"
Minimum
From
Sides Of
Fireplace
Left
Side
FLOOR
Figure 7 - Mounting Clearances As Viewed From Front of
Fireplace Shown Built In The Wall
CEILING
Top Of
Mantel Can
Be Flush
With Wall
Right
Side
36"
Minimum
0" Minimum To Top
Surface Of Carpeting,
Tile Or Other
Combustible Material
CAUTION: This fireplace creates warm air currents. These currents move heat to wall surfaces next
to fireplace. Installing fireplace next to vinyl or cloth
wall coverings or operating fireplace where impurities
(such as, but not limited to, tobacco smoke, aromatic
candles, cleaning fluids, oil or kerosene lamps, etc.) in
the air exist, may discolor walls or cause odors.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
Left
Side
Right
Side
0" Minimum To Top
Surface Of Carpeting,
Tile Or Other
Combustible Material
Figure 8 - Mounting Clearances As Viewed From Front of
Fireplace Shown with Optional Mantel
111044-01A
INSTALLATION
36
5
/8
"
25
7
/8
"
51
3
/4
"
26
7
/8
"
Continued
Locating Fireplace (Cont.)
INSTALLATION
Built-In Fireplace Installation
9
9
For convenience and efficiency, install fireplace
• where there is easy access for operation, inspection, and service.
• in coldest part of room
An optional blower kit is available from your dealer. See Accesso-
ries, page 29. If planning to use blower, locate fireplace near an
electrical outlet.
BUILT-IN FIREPLACE INSTALLATION
Built-in installation of this fireplace involves installing fireplace into
a framed-in enclosure. This makes the front of fireplace flush with
wall. An optional brass trim kit accessory is available (see Accesso-ries, page 29). Brass trim will extend past sides of fireplace approximately 1/2 inch. This will cover the rough edges of the wall opening.
If installing a built-in mantel above the fireplace, you must follow the
clearances shown in Figure 12, page 10. Follow the instructions
below to install the fireplace in this manner.
Glow fireplace is designed to be used in zero clearance installations.
Wall or framing material can be placed directly against any exterior
surface on the rear, sides, or top of your fireplace.
1.Frame in rough opening. Use dimensions shown in Figure 9 for
the rough opening.
If installing in a corner, use dimensions shown in Figure 10
for the rough opening. The height is 26 7/8" which is the same
as the wall opening above.
2.If installing GA3450T blower accessory, do so at this time. Follow instructions included with blower accessory.
installing blower accessory, you may wish to run electrical wir ing to your fireplace for future blower installation (see Accesso-ries, page 29). Use only approved three-wire electrical wiring.
Note:
A qualified installer should make all electrical connections.
Note:
3
/4"
Your Comfort
Note:
If not
3.Install gas piping to fireplace location. This installation includes
an approved flexible gas line (if allowed by local codes) after
the equipment shutoff valve. The flexible gas line must be the
last item installed on the gas piping.
4.If you have not assembled firebox, follow instructions on page 4.
5.Carefully set fireplace in front of rough opening with back of
fireplace inside wall opening.
6.Attach flexible gas line to fireplace gas regulator. See Con-necting to Gas Supply, page 14.
7.Bend four nailing flanges on outer casing with pliers (see
Figure 11).
8.Attach fireplace to wall studs using nails or wood screws
through holes in nailing flange.
9.Check all gas connections for leaks. See Checking Gas Con-nections, page 16.
10. If using optional brass trim kit, install the trim after final finishing and/or painting of wall. See instructions included with
brass trim accessory for attaching brass trim.
IMPORTANT:
When finishing your firebox, combustible materials
such as wall board, gypsum board, sheet rock, drywall, plywood, etc.
may be butted up next to the sides and top of the firebox. Combustible
materials should never overlap the firebox front facing.
1
10
/
2
"
7
/
8
"
26
3/4" Off
7
26
/
8
"
Figure 9 - Rough Opening for
Installing in Wall
The Floor
Minimum
Figure 10 - Rough Opening
for Installing in Corner
WARNING: If pre-wiring, do not connect wiring to
any electrical source at this time.
Install fireplace electrical outlet and connect wiring
to outlet before connecting to electrical source. The
fireplace electrical outlet is included with the GA3450T
blower accessory.
Only use the fireplace electrical outlet supplied with
the GA3450T blower accessory.
For more information, visit www.desatech.com
111044-01A
For more information, visit www.desatech.com
Nails or Wood
Screws
Nailing
Flanges
Figure 11 - Attaching Fireplace to Wall Studs
Loading...
+ 21 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.