VENT-FREE NATURAL GAS
COMPACT FIREPLACE
OWNER’S OPERATION AND INSTALLATION MANUAL
CGCF26NR
Remote/Thermostatically
Controlled Model
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result caus­ing property damage, personal injury, or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a
qualified installer, service agency, or the gas supplier.
®
Shown with Optional Cabinet Mantel/Hearth Base Accessory
WARNING: Improper installa­tion, adjustment, alteration, ser­vice, or maintenance can cause injury or property damage. Re­fer to this manual for correct installation and operational pro­cedures. For assistance or ad­ditional information consult a qualified installer, service agency, or the gas supplier.
WARNING: This is an unvented gas-fired heater. It uses air (oxy­gen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to
Combustion and Ventilation
tion on page 5 of this manual.
Air for
sec-
This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer. (I.E. Installation of this product is permitted after the manufactured (mobile) home is sited)
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
Save this manual for future reference.
CGCF26NR
VENT-FREE NATURAL GAS COMPACT FIREPLACE
SAFETY INFORMATION
WARNINGS
WARNING ICON G 001
IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, oper­ate, or service this fireplace. Im­proper use of this fireplace can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.
DANGER: Carbon monoxide
poisoning may lead to death!
Carbon Monoxide Poisoning: Early
signs of carbon monoxide poisoning re­semble the flu, with headaches, dizziness, or nausea. If you have these signs, the fire­place may not be working properly. Get fresh air at once! Have fireplace serviced. Some people are more affected by carbon monoxide than others. These include preg­nant women, people with heart or lung dis­ease or anemia, those under the influence of alcohol, and those at high altitudes.
Natural Gas: Natural gas is odorless. An odor-making agent is added to natural gas. The odor helps you detect a natural gas leak. However, the odor added to natural gas can fade. Natural gas may be present even though no odor exists.
Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.
WARNING: Any change to this fireplace or its controls can be dangerous.
1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
2. If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not use any phone in your building.
• immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions
• if you cannot reach your gas supplier, call the fire department
3. This fireplace shall not be installed in a bedroom or bathroom.
4. Never install the fireplace
• in a recreational vehicle
• where curtains, furniture, clothing, or
other flammable objects are less than 36 inches from the front, top, or sides of the fireplace
• as a fireplace insert
• in high traffic areas
• in windy or drafty areas
5. Do not use this fireplace as a wood­burning fireplace. Use only the logs provided with the fireplace.
6. Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of fireplace.
7. Y ou must operate this fireplace with the fireplace screen in place. Make sure fireplace screen is in place before run­ning fireplace.
8. This fireplace is designed to be smoke­less. If logs ever appear to smoke, turn off fireplace and call a qualified ser­vice person. eration, slight smoking could occur due to log curing and fireplace burning manufacturing residues.
9. Do not allow fans to blow directly into the fireplace. Avoid any drafts that al­ter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.
10. Before using furniture polish, wax, car­pet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white pow­der residue within burner box or on adjacent walls or furniture.
Note:
During initial op-
11. This fireplace needs fresh air ventila­tion to run properly . This fireplace has an oxygen depletion sensor (ODS) pi­lot light safety system. The ODS shuts down the fireplace if not enough fresh air is available. See Air for Combus- tion and Ventilation, pages 5 through
7. If fireplace keeps shutting off, see Troubleshooting, pages 17 through 19.
12. Do not run fireplace
• where flammable liquids or vapors
are used or stored.
• under dusty conditions.
13. Do not use this fireplace to cook food or burn paper or other objects.
14. Never place any objects in the fireplace or on logs.
15. Fireplace front and screen becomes very hot when running fireplace. Keep children and adults away from hot sur­faces to avoid burns or clothing igni­tion. Fireplace will remain hot for a time after shut-down. Allow surfaces to cool before touching.
16. Carefully supervise young children when they are in same room with fire­place.
17. Do not use fireplace if any part has been under water. Immediately call a quali­fied service technician to inspect the room fireplace and to replace any part of the control system and any gas con­trol which has been under water.
18. Turn off and unplug fireplace and let cool before servicing. Only a qualified service person should service and re­pair fireplace.
19. Operating fireplace above elevations of 4,500 feet could cause pilot outage.
20. Do not use a blower insert, heat ex­changer insert, or other accessory not approved for use with this fireplace.
21. Do not operate fireplace if any log is broken. Do not operate fireplace if a log is chipped (dime-sized or larger).
2
104326
OWNER’S MANUAL
PRODUCT IDENTIFICATION
Fireplace Cabinet
ON
OFF
REMOTE
Ignitor Button
Remote Selector Switch
Figure 1 - Vent-Free Natural Gas Compact Fireplace
Flame Adjustment Knob
Control Knob
Screen
Logs
PRODUCT FEATURES
Safety Pilot
This fireplace has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent­free room fireplaces. The ODS/pilot shuts off the fireplace if there is not enough fresh air.
Piezo Ignition System
This fireplace has a piezo ignitor. This sys­tem requires no matches, batteries, or other sources to light fireplace.
HI
TEMP
MAN
AUTO
ONLO
OFF
STATUS
Remote
LOCAL CODES
Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1, also known as NFPA 54*.
*Available from: American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
UNPACKING
1. Remove log box and fireplace from carton. The hood is not attached.
2. Remove all protective packaging ap­plied to fireplace for shipment.
3. Make sure your fireplace includes one hardware packet and one remote con­trol packet which includes batteries.
4. Check fireplace for any shipping damage. If fireplace is damaged, promptly inform dealer where you bought fireplace.
104326
3
CGCF26NR
VENT-FREE NATURAL GAS COMPACT FIREPLACE
ASSEMBLY
WARNING: Always have branch support and screen in place before operating fireplace. This prevents excessive tempera­tures on fireplace surfaces.
ASSEMBLING FIREPLACE
Tools Required:
• Phillips screwdriver
• 5/16" hex wrench
• Slotted screwdriver
Installing Log
1.
Remove back log, branch, and hood from log box. Discard protective packaging.
2. Remove two shipping screws above screen (see Figure 2).
3. Lift screen up and pull out to remove.
4. An optional blower is available. See Ac- cessories, page 21. Install optional blower now. Follow installation in­structions provided with blower.
5. Gently place back log on burner sup­port (see Figure 2). The log should fit flat against top of burner support. Place two #10 one-inch-long screws through burner support into the log and tighten. Place branche on branch support (see Figure 2).
6. Do not allow branch to contact flame. If flame contacts branch, soot will be created.
7. Reattach screen by placing notches in screen frame over shoulder screws and pushing down.
Screen Shipping Screw
Back Log
Screw
Branch
Screen
Figure 2 - Assembling Fireplace
Assembling Hood
1. Locate four #10-3/8" black phillips sheet metal screws from the hardware packet.
2. Remove two 13/4" screws from under­neath middle rail (see Figure 3).
3. Slip top of hood between middle rail and top of firebox wrapper (see Figure 3).
Shoulder Screw
Burner Support
Branch Support
Screw
4. Reinstall two 13/4" screws removed in step 2. Make sure screw pass through hood and middle rail and attach into upper louver assembly (see Figure 3).
5. Attach four #10-3/8" hood screws as shown in Figure 3.
WARNING: Failure to posi­tion the parts in accordance with these diagrams or failure to use only parts specifically approved with this fireplace may result in property damage or personal injury.
Figure 3 - Assembling Hood
4
2 Short Screws
3
/4"
1 Screws
Middle Rail
Hood
Firebox Top
104326
OWNER’S MANUAL
AIR FOR COMBUSTION AND VENTILATION
WARNING: This heater shall not be installed in a confined space or unusually tight con­struction unless provisions are provided for adequate combus­tion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.
Today’s homes are built more energy effi­cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.
While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper com­bustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide ad­equate fresh air for these appliances. This will insure proper venting of vented fuel­burning appliances.
PROVIDING ADEQUATE VENTILATION
The following is excerpts from National Fuel Gas Code. NFPA 54/ANSI Z223.1, Section
5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three following ventilation classifications:
1. Unusually Tight Construction
2. Unconfined Space
3. Confined Space The information on pages 5 through 7 will
help you classify your space and provide adequate ventilation.
Unusually Tight Construction
The air that leaks around doors and win­dows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.
Unusually tight construction is de­fined as construction where:
a. walls and ceilings exposed to the
outside atmosphere have a con­tinuous water vapor retarder with a rating of one perm (6 x 10 per pa-sec-m2) or less with open­ings gasketed or sealed
b. weather stripping has been
added on openable windows and doors
c. caulking or sealants are applied
to areas such as joints around window and door frames, be­tween sole plates and floors, be­tween wall-ceiling joints, be­tween wall panels, at penetra­tions for plumbing, electrical, and gas lines, and at other openings.
If your home meets all of the three criteria above, you must provide ad­ditional fresh air. See
From Outdoors
If your home does not meet all of the three criteria above, proceed to
and
, page 7
Ventilation Air
.
mining Fresh-Air Flow For Fireplace Location,
page 6.
-11
and
Deter-
kg
Confined and Unconfined Space
The National Fuel Gas Code (ANSI Z223.1, 1992 Section 5.3) defines a confined space
as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfining space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are in­stalled*, through openings not furnished with doors, are considered a part of the unconfined space.
This heater shall not be installed in a con­fined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.
* Adjoining rooms are communicating only if there are doorless passageways or ventila­tion grills between them.
104326
Continued
5
CGCF26NR
VENT-FREE NATURAL GAS COMPACT FIREPLACE
AIR FOR COMBUSTION AND VENTILATION
Continued
DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION
Determining if You Have a Confined or Unconfined Space
Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install fireplace plus any adjoining rooms with doorless passageways or ventilation grills
between the rooms.
1. Determine the volume of the space (length x width x height). Length x Width x Height = _________________cu. ft. (volume of space)
Example:
If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.
2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.
_________________ (volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support)
Example:
3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free fireplace ________________ Btu/Hr Gas water heater ________________ Btu/Hr Gas furnace ________________ Btu/Hr Vented gas heater ________________ Btu/Hr Gas fireplace logs ________________ Btu/Hr Other gas appliances* + ________________ Btu/Hr Total = ________________ Btu/Hr * Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.
4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
_____________ Btu/Hr (maximum the space can support) _____________ Btu/Hr (actual amount of Btu/Hr used)
Example:
The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:
A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin-
ing room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 7.
B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 7. C. Install a lower Btu/Hr fireplace, if lower Btu/Hr size makes room unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.
Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)
2560 cu. ft. (volume of space) ÷ 50 cu. ft. = 51.2 or 51,200 (maximum Btu/Hr the space can support)
Example:
Gas water heater 30,000 Btu/Hr Vent-free fireplace + 26,000 Btu/Hr Total = 56,000 Btu/Hr
51,200 Btu/Hr (maximum the space can support) 56,000 Btu/Hr (actual amount of Btu/Hr used)
WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the
National Fuel Gas Code, ANSI Z223.1, 1992, Section 5.3
6
or applicable local codes.
104326
AIR FOR
Or
Remove Door into Adjoining
Room,
Option 3
Ventilation Grills
Into Adjoining Room,
Option 2
12"
12"
Ventilation
Grills
into Adjoining
Room,
Option 1
COMBUSTION AND VENTILATION
Continued
VENTILATION AIR
Ventilation Air From Inside Building
This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro­vide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 4). You can also remove door into adjoining room (see op­tion 3, Figure 4). Follow the National Fuel
Gas Code NFPA 54/ANSI Z223.1, Section
5.3, Air for Combustion and Ventilation for
required size of ventilation grills or ducts.
OWNER’S MANUAL
WARNING: Rework work­sheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces.
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or ducts. You must provide two per­manent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces.
IMPORTANT:
Do not provide openings for
inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.
Figure 4 - Ventilation Air from Inside Building Shown with Optional Mantel
Outlet Air
Outlet Air
Inlet Air
Inlet Air
Figure 5 - Ventilation Air from Outdoors Shown with Optional Mantel
Ventilated Attic
To Attic
To
Crawl
Space
Ventilated
Crawl Space
104326
7
CGCF26NR
6" Minimum From Sides Of Fireplace
Left Side
CEILING
36" Minimum
FLOOR
Right Side
VENT-FREE NATURAL GAS COMPACT FIREPLACE
INSTALLATION
NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri­mary heating system. Do not in­stall this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circu­late the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.
NOTICE: A qualified service per­son must install fireplace. Follow all local codes.
Note:
Your Comfort Glow fireplace is de­signed to be used in zero clearance installations. Wall or framing material can be placed directly against any exterior surface on the fireplace, except where stand-off spacers are integrally attached. If stand-off spacers are attached to your fireplace, these spacers can be placed directly against wall or framing materials.
Use the dimensions shown for rough openings to create the easiest installation (see Built-In Fireplace Installation, page 8).
CHECK GAS TYPE
Use only natural gas. If your gas supply is not natural gas, do not install fireplace. Call dealer where you bought fireplace for proper type fireplace.
INSTALLATION ITEMS
Before installing fireplace, make sure you have the items listed below.
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• manual shutoff valve *
• ground joint union
• sediment trap
• tee joint
• pipe wrench
• test gauge connection* * An A.G.A. design-certified manual shutoff
valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Pur­chase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 21.
Note:
for built-in installations. See Accessories, page 21.
If desired, purchase a four-sided brass trim kit
LOCATING FIREPLACE
WARNING: Maintain the mini­mum clearances shown in Fig­ures 6 and 7. If you can, provide greater clearances from floor, ceiling, and joining wall.
You can recess firebox into the wall. You can also position fireplace in the optional cabinet or corner mantels.
IMPORTANT:
or corner mantels specified in this manual. Purchase the optional mantel from your dealer (see Accessories, page 21).
WARNING: Never install the fireplace
• in a bedroom or a bathroom
• in a recreational vehicle
• where curtains, furniture,
clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the fireplace
• as a fireplace insert
• in high traffic areas
• in windy or drafty areas
CAUTION: This fireplace cre­ates warm air currents. These currents move heat to wall sur­faces next to fireplace. Installing fireplace next to vinyl or cloth wall coverings or operating fire­place where impurities (such as tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls.
IMPORTANT:
ture to the air. Although this is beneficial, installing fireplace in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 5 through 7.
CAUTION: If you install the fireplace in a home garage
• fireplace pilot and burner must
be at least 18 inches above floor.
• locate fireplace where moving
vehicle will not hit it.
Only use optional cabinet
Vent-free fireplaces add mois-
For convenience and efficiency, install fire­place
• where there is easy access for operation, inspection, and service.
• in coldest part of room.
An optional blower kit is available from your dealer. See Accessories, page 21. If planning to use blower, locate fireplace near an electrical outlet.
Figure 6 - Mounting Clearances As Viewed From Front of Fireplace Shown Built In The Wall
CEILING
36" Minimum
Top Of Mantel Can Be Flush With Wall
Right
Left Side
Figure 7 - Mounting Clearances As Viewed From Front of Fireplace Shown with Optional Mantel
Side
8
104326
OWNER’S MANUAL
INSTALLATION
Continued
BUILT-IN FIREPLACE INSTALLATION
Built-in installation of this fireplace involves installing fireplace into a framed-in enclo­sure. This makes the front of fireplace flush with wall. An optional brass trim kit acces­sory is available (see Accessories, page 21). Brass trim will extend past sides of fireplace approximately 1/2 inch. This will cover the rough edges of the wall opening. If install­ing a built-in mantel above the fireplace, but you must follow the clearances shown in Figure 11, page 10. Follow the instructions below to install the fireplace in this manner.
Actual Framing
Height 26" 26
Front Width 26
Depth 9 1/2" 10 1/2"
Bottom
3
/4" 26 7/8"
3/4" 3/4"
1. Frame in rough opening. Use dimen­sions shown in Figure 8 for the rough opening.
If installing in a corner, use dimensions shown in Figure 9 for the rough open­ing. The height is 26 1/8" which is the same as the wall opening above.
10 1/2"
26 7/8"
26 7/8"
Figure 8 - Rough Opening for Installing in Wall
36 5/8"
7
/8"
3/4" Off The Floor Minimum
25 7/8"
2. An optional blower accessory is avail­able (see Accessories, page 21). There are two options for connecting blower to electrical source.
Option one: Have a licensed electri­cian install a properly grounded, three­prong 120-volt electrical outlet at fire­place location. Locate outlet inside the framed enclosure. Blower power cord will plug into this outlet.
Option two: Have a licensed electri­cian connect blower to electrical source at junction box inside fireplace.
If using option one, have electrical out­let installed at this time. If using option two, do not connect blower to electrical source at junction box until step 7.
3. Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the manual shutoff valve. The flexible gas line must be the last item installed on the gas piping.
4. If you have not assembled firebox, fol­low instructions on page 4.
5. Carefully set fireplace in front of rough opening with back of fireplace inside wall opening.
6. Attach flexible gas line to fireplace gas regulator. See Connecting Fir eplace to Gas Supply, page 12.
7. If the optional blower has been installed connect blower to electrical source.
Option one: Route blower electrical cord through side or rear access door of fireplace. Plug electrical cord into electrical outlet.
Nails or Wood Screws
Option two: Have a licensed electri­cian connect blower to electrical source at junction box inside fireplace.
8. Bend four nailing flanges on outer cas­ing with pliers (see Figure 10).
9. Attach fireplace to wall studs using nails or wood screws through holes in nailing flange.
10. Check all gas connections for leaks. See Checking Gas Connections, page 13.
11. If using optional brass trim kit, install the trim after final finishing and/or painting of wall. See instructions in­cluded with brass trim accessory for at­taching brass trim.
IMPORTANT:
When finishing your fire­box, combustible materials such as wall board, gypsum board, sheet rock, drywall, plywood, etc. may be butted up next to the sides and top of the firebox. Combustible materials should never overlap the firebox front facing.
WARNING: Do not allow any combustible materials to overlap the firebox front facing.
IMPORTANT:
Non-combustible materials such as brick, tile, etc. may overlap the front facing, but should never cover any neces­sary openings like louvered slots.
WARNING: Do not allow non­combustible materials to cover any necessary openings like lou­vered slots.
WARNING: Never modify or cover the louvered slots on the front of the firebox.
WARNING: Use only non-com­bustible mortar or adhesives when overlapping the front fac­ing with non-combustible facing material.
26 7/8"
51 3/4"
Figure 9 - Rough Opening for Installing in Corner
104326
Nailing Flanges
Figure 10 - Attaching Fireplace to Wall Studs
9
Continued
CGCF26NR
VENT-FREE NATURAL GAS COMPACT FIREPLACE
INSTALLATION
Continued
MANTEL CLEARANCES FOR BUILT-IN INSTALLATION
If placing mantel above built-in fireplace, you must meet minimum clearance between mantel shelf and top of fireplace opening.
If your installation does not meet the above minimum clearances, you must:
• raise the mantel to an acceptable height, OR
• remove the mantel.
OPTIONAL MANTEL INSTALLATION
Note:
Refer to instructions provided with the mantel for assembly instructions. Refer to instructions below for system installa­tion. Refer to instructions on page 4 for firebox assembly. Blower accessory should be installed if it is being used (see Accesso- ries, page 21).
1. Unscrew four brass screws that attach
top louver to fireplace. Remove louvre from fireplace and set aside.
2. Place fireplace on wood base.
3. Place mantel around fireplace/base as-
sembly.
4. Assemble brass trim kit. See Assem-
bling Brass Trim.
5. Firmly snap brass trim kit on shoulder
screws. Shoulder screws are located on fireplace cabinet (see Figure 12).
6. Align brass trim kit for flush fit around
opening.
7. Use two 3" wood screws provided and
attach fireplace base to wooden base (see Figure 12).
8. Remove brass trim kit and mantel. Be
careful not to damage wall or mantel.
9. Place wood base next to wall at instal-
lation location.
10. Attach wood base to floor with two
1 3/4" black screws provided (see Fig­ure 13). If the floor is concrete use an­chor method (see Attaching W ood Base to Solid Floor, page 11).
11. Install gas line. See Connecting T o Gas
Supply, page 11.
12. Check for leaks. See Checking Gas
Connections, page 13.
13. Place mantel around fireplace. Be care­ful not to damage wall or mantel.
14. Place brass trim kit on the shoulder screws located on the side and top of the fireplace. Firmly snap the brass trim over the shoulder screws on fireplace (see Figure 12).
15. Adjust assembly to remove any gaps. At­tach remaining two 3" wood screws from hardware pack through openings inside of fireplace sides into the mantel. The open­ings are located at top behind the area for the brass louvers (see Figure 13).
16. Reinstall top brass louvers.
Note:
All vertical measurements are from top of fireplace opening to bottom of mantel shelf.
Minimum Non­Combustible Material
Figure 11 - Minimum Mantel Clearances for Built-In Installation
Shoulder Screws
Hole for 3" wood screw for attaching fireplace to mantel
Figure 12 - Attaching Brass Trim to Fireplace
Mantel Shelf
10" 8" 6" 2 1/2"
13"
16"
Hole for 3" wood screw for attaching fireplace to wooden base
Assembled Brass Trim
19"
21"
1 3/4" Screw
Wood Base
Figure 13 - Attaching Wood Base to Floor
Assembling Brass Trim (Brass trim shipped with mantel)
1. Remove packaging from three remain­ing pieces of brass trim.
2. Locate two adjusting plates with set screws, and two shims in the hardware packet.
3. Align shim under adjusting plate as shown in Figure 14.
4. Slide one end of adjusting plate/shim in slot on mitered edge of top brass trim (see Figure 14).
5. Slide other end of adjusting plate/shim in slot on mitered edge of side brass trim (see Figure 14).
6. While firmly holding edges of brass trim together, tighten both set screws on the adjusting plate with slotted screwdriver.
7. Repeat steps 1 through 6 for other corner.
8. Set Brass Assembly aside for later in­stallation.
Slot
Set Screws
Shim
Adjusting Plate
Slot
Figure 14 - Assembling Brass Trim
Top Brass Trim
Mitered Edge
Side Brass Trim
10
104326
OWNER’S MANUAL
INSTALLATION
Continued
Attaching Wood Base to Solid Floor
For attaching base to solid floors (concrete or masonry)
Note:
Floor anchors and mounting screws are in hardware package. The hardware pack­age is provided with fireplace.
1. Drill holes at marked locations using
5/16" drill bit. For solid floors (concrete or masonry), drill at least 1" deep.
2. Fold floor anchor as shown in Figure 15.
3. Insert floor anchor (wings first) into
hole. Tap anchor flush to floor.
4. Insert mounting screws through base
and into floor anchors.
5. Tighten screws until base is firmly fas-
tened to floor.
Figure 15 - Folding Anchor
CONNECTING TO GAS SUPPLY
NOTICE: A qualified service per­son must connect fireplace to gas supply. Follow all local codes.
WARNING: Never connect fireplace to private (non-utility) gas wells. This gas is commonly known as wellhead gas.
IMPORTANT:
before connecting fireplace to gas line. Gas line pressure must be no greater than 14 inches of water. If gas line pressure is higher, fireplace regulator damage could occur.
CAUTION : Use only new, black iron or steel pipe. Inter­nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" or greater diameter to allow proper gas volume to fireplace. If pipe is too small, undue loss of pressure will occur.
From Gas Meter (5" W.C.** to
10.5" W.C. Pressure)
Check gas line pressure
A.G.A. Design-Certified Manual Shutoff Valve With 1/8" NPT Tap*
Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 16).
Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.
CAUTION: Use pipe joint seal­ant that is resistant to liquid pe­troleum (LP) gas.
Install sediment trap in supply line as shown in Figure 16. Locate sediment trap where it is within reach for cleaning. Locate sedi­ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.
Approved Flexible Gas Hose
104326
Gas Control
Tee
Sediment Trap
Figure 16 - Gas Connection
Joint Pipe
Nipple Cap
3" Minimum
* Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 21.
** Minimum inlet pressure for purpose of input adjustment.
Continued
11
CGCF26NR
VENT-FREE NATURAL GAS COMPACT FIREPLACE
INSTALLATION
Continued
CONNECTING FIREPLACE TO GAS SUPPLY
Installation Items Needed
• Phillips screwdriver
• sealant (resistant to propane gas, not pro­vided)
1. Remove fireplace screen. Remove two
screws that hold fireplace screen in place for shipping. These screws are located near top of screen. Discard screws. Lift fireplace screen up and pull out to remove.
2. Remove screws that attach branch sup-
port to fireplace (see Figure 17). Care­fully lift up branch support and remove from fireplace (see Figure 17).
3. Route flexible gas line (provided by
installer) from manual shutoff valve into fireplace through side or rear ac­cess holes in outer casing. Route flex­ible gas supply line through fireplace access holes in outer casing.
Screen Shipping Screw
Shoulder Screw
Figure 17 - Removing Branch Support From Fireplace
Gas Connector
Manual Shutoff Valve
Screen
Branch Support
To Fireplace Gas Valve
NOTICE : Most building codes do not permit concealed gas con­nections. A flexible gas line is provided to allow accessibility from the fireplace (see Figure 18). The flexible gas supply line con­nection to the manual shutoff valve should be accessible.
4. Apply pipe joint sealant lightly to male
threads of gas connector attached to flexible gas line (see Figure 18). Con­nect flexible gas line to flexible gas line attached to gas valve of fireplace (see Figure 18).
5. Check all gas connections for leaks. See
Checking Gas Connections, page 13.
6. Replace branch support back into fire-
place. Feed flexible gas line into fire­place base area while replacing branch support. Make sure the entire flexible gas line is in fireplace base area. Reat­tach branch support to fireplace with screws removed in step 3.
To Gas Supply
Figure 18 - Attaching Flexible Gas Lines Together
Flexible Gas Line from Manual Shutoff Valve Provided by Installer
Flexible Gas Line from Fireplace Gas Valve Provided with Fireplace
12
104326
OWNER’S MANUAL
O
O
INSTALLATION
Continued
CHECKING GAS CONNECTIONS
WARNING: Test all gas pip­ing and connections for leaks after installing or servicing. Cor­rect all leaks at once.
WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.
Pressure Testing Gas Supply Piping System
Test Pressures In Excess Of 1/2 PSIG
1. Disconnect fireplace and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage fireplace regulator.
2. Cap off open end of gas pipe where manual shutoff valve was connected.
3. Pressurize supply piping system by ei­ther using compressed air or opening main gas valve located on or near gas meter.
4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles form­ing show a leak.
5. Correct all leaks at once.
Test Pressures Equal To or Less Than 1/2 PSIG
1. Close manual shutoff valve (see Figure 19).
2. Pressurize supply piping system by ei­ther using compressed air or opening main gas valve located on or near gas meter.
3. Check all joints from gas meter to manual shutoff valve (see Figure 20). Apply mixture of liquid soap and wa­ter to gas joints. Bubbles forming show a leak.
4. Correct all leaks at once.
Pressure Testing Fireplace Gas Connections
1. Open manual shutoff valve (see Fig­ure 19).
2. Open main gas valve located on or near gas meter.
3. Make sure control knob of fireplace is in the OFF position.
4. Check all joints from manual shutoff valve to thermostat gas valve (see Fig­ure 20). Apply mixture of liquid soap and water to gas joints. Bubbles form­ing show a leak.
5. Correct all leaks at once.
6. Light fireplace (see Operating Fire- place, pages 14 and 15). Check all other internal joints for leaks.
7. Turn off fireplace (see To Turn Off Gas to Appliance, page 15).
8. Replace front panel.
Open
POSI
Manual Shutoff Valve
P
Closed
Figure 19 - Manual Shutoff Valve
Manual Shutoff
Gas Meter
Figure 20 - Checking Gas Joints
Valve
INSTALLING 9-VOLT BATTERY FOR WIRELESS REMOTE CONTROL
Two 9-volt batteries (not included) are re­quired to operate this heater with the wire­less hand held remote control set. One bat­tery must be installed in the receiver and one in the hand-held remote control unit. Only use alkaline batteries.
Installing 9-Volt Battery in Receiver
1. Locate back of receiver located at the bottom, left side of the heater base.
2. Locate the battery clip mounted on the back of the receiver.
3. Slide a 9-volt battery through the clip.
4. Attach the terminal wires to the battery.
Receiver
Battery Clip
9-Volt Battery
Figure 21 - Attaching Battery to Receiver
Installing 9-Volt Battery in Hand­Held Remote Control Unit
1. Remove battery cover on back of re­mote control unit.
2. Attach terminal wires to the battery. Place battery into the battery housing.
3. Replace battery cover onto remote con­trol unit.
Battery Cover
Terminal Wires
9-Volt Battery
Remote Control Unit
Battery Housing
Note:
Terminal Wires
104326
Figure 22 - Installing Battery in Hand­Held Remote Control Unit
13
CGCF26NR
VENT-FREE NATURAL GAS COMPACT FIREPLACE
OPERATING FIREPLACE
FOR YOUR SAFETY
READ BEFORE
LIGHTING
WARNING: If you do not fol­low these instructions exactly, a fire or explosion may result caus­ing property damage, personal injury or loss of life.
A. This appliance has a pilot which must
be lighted by hand. When lighting the pilot, follow these instructions exactly .
B. BEFORE LIGHTING smell all
around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas sup­plier, call the fire department.
C. Use only your hand to push in or turn
the gas control knob. Ne ver use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part
has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been un­der water.
LIGHTING
INSTRUCTIONS
WARNING: You must operate this heater with a fireplace screen in place. Make sure fireplace screen is installed before run­ning heater.
NOTICE: During initial operation of new fireplace, burning logs will give off a paper-burning smell. Orange flame will also be present. Open window to vent smell. Operate fireplace on HI position to burn off odor. This will only last a few hours.
1. STOP! Read the safety information, column 1.
2. Make sure manual shutoff valve is fully open.
3. Set remote selector switch in the OFF position.
WARNING: Burners will come on automatically within one minute when the remote selector switch is in the ON position after the pilot is lit.
4. Press in and turn control knob clock­wise to the OFF position.
5. Wait f ive (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in­formation, column 1. If you don’t smell gas, go to the next step.
6. Press in and turn control knob coun­terclockwise to the PILOT position. Press in control knob for five (5) seconds (see above).
Note:
You may be running this
heater for the first time after hook-
Control Knob
ing up to gas supply. If so, the con­trol knob may need to be pressed in for 30 seconds or more. This will al­low air to bleed from the gas system.
7. With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep press­ing ignitor button until pilot lights.
Note:
If pilot does not stay lit, con­tact a qualified service person or gas supplier for repairs. Until repair s are made, light pilot with match. T o light pilot with match, see Manual Light- ing Procedure on page 15.
8. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
• If control knob does not pop out
when released, contact a qualified service person or gas supplier for repairs.
Note:
If pilot goes out, repeat steps
4 through 8.
9. Slightly push in and turn control knob counterclockwise to the ON position.
10. Wait one minute and switch remote selector switch to the ON position to light burner.
11. Set flame adjustment knob to any level between HI and LO.
CAUTION: Do not try to adjust heating levels by using the manual shutoff valve.
WARNING: Make sure the remote selector switch is in the OFF position when you are away from home for long periods of time. Heater will come on auto­matically with remote selector switch in the ON position.
Pilot Burner
Ignitor Electrode
O
14
L
H
I
O
T
L
I
P
REMOTE OFF
Selector Switch in OFF Position
Figure 23 - Control Knob and Ignitor Button Location Figure 24- Pilot
ON
Ignitor Button
O
N
F
F
O
Flame Adjustment Knob
104326
OWNER’S MANUAL
OPERATING FIREPLACE
Continued
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Fireplace
1. T urn control knob clockwise to the OFF position.
2. Set remote selector switch in the OFF position to prevent draining battery.
Shutting Off Burner Only (pilot stays lit)
You may shut off the burners and keep the pilot lit by doing one of the following:
1. T urn control knob clockwise to the PILOT position.
2. Use remote control manual OFF b utton.
3. Set remote selector switch in the OFF position.
THERMOSTAT
CONTROL
OPERATION
The thermostat control setting on the remote control unit can be set to any comfort level between HI and LO. The burners will turn on and off automati­cally to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 6 under Lighting Instructions, page 14.
2. Depress control knob and light pilot with match.
3. Keep control knob pressed in f or 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 9 on page 14.
HAND HELD REMOTE
OPERATION
NOTICE: You must light the pilot before using the hand-held re­mote control unit. See
Instructions
on page 14.
1. After lighting, let pilot flame burn for about one minute. T ur n control knob to ON position. Adjust flame adjust­ment knob anywhere between HI and LO. Slide the remote selector switch to the REMOTE position. The burners will come on. You can now turn the burners on and off with the hand-held remote control unit.
IMPORTANT:
Do not leave the re­mote selector switch in the REMOTE position when the pilot is not lit. This will drain the battery.
2. Select the MANUAL or AUTO but­ton on the hand-held remote control unit.
• In MANUAL mode, turn burners
on or off by pressing the ON or OFF buttons on the hand-held re­mote control unit.
• In A UTO mode, the room tempera-
ture is controlled by the thermo­stat in the hand-held remote con­trol unit. To increase the room tem-
REMOTE OFF ON
Remote Selector Switch in Remote Position
Figure 25 - Setting the Remote Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation
Shows Temperature Setting
Allows Burners to be Turned On and Off with the Hand-Held Remote Unit.
The log heater will automatically cycle between pilot and the heat setting that has been selected.
Lighting
HI
LO
MAN ON
AUTO OFF
STA TUS
TEMP
perature, press the top arrow of the TEMP button. To lower room the temperature, press the bottom ar­row to the TEMP b utton. At higher settings the heater will run more.
IMPORTANT:
The hand-held re­mote control unit must be near the heater. Do not keep the hand-held remote control unit too close the heater. The thermostat on the hand-held remote control unit will heat up too quickly and turn the heater off.
3. Use the ST A TUS button on the hand­held remote control unit to see the operation mode being used and the temperature setting selected. A red light will come on beside the opera­tion mode being used when the sta­tus button is pressed.
4. To turn the burners off when oper­ating in the MANUAL mode, press the OFF button. If operating in the auto mode, press the manual button, then press the OFF button The pilot will remain lit.
IMPORTANT:
To turn the pilot off, manually turn the control knob on the heater to the OFF position or set re­mote selector switch to OFF position.
Control Knob in On Position
N
O
T
O
L
I
Increases Room Temperature
Decreases Room Temperature
Turns Burners On and Off
Shows Current Operation Mode
Flame Adjustment Knob
O
L
O
F
F
P
H
I
104326
Figure 26 - Thermostat Hand-Held Remote Control Unit Selections
15
CGCF26NR
VENT-FREE NATURAL GAS COMPACT FIREPLACE
INSPECTING BURNERS
Check pilot flame pattern and burner flame patterns often.
PILOT FLAME PATTERN
Figure 27 shows a correct pilot flame pat­tern. Figure 28 shows an incorrect pilot flame pattern. The incorrect pilot flame is not properly heating the thermocouple. When the thermocouple cools, the heater will shut down.
If pilot flame pattern is incorrect, as shown in Figure 28
• turn heater off (see To Turn Off Gas to Appliance, page 15.
• see T roubleshooting, pages 17 through 19.
Pilot Burner
Figure 27 - Correct Pilot Flame Pattern
Pilot Burner
Figure 28 - Incorrect Pilot Flame Pattern
BURNER FLAME PATTERN
Figure 29 shows a correct burner flame pattern. Figure 30 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame. It also shows the flame higher than one inch above the log.
Note:
When using the fireplace the first time, the flame will be yellow for approxi­mately one hour until the log cures.
WARNING: If yellow tipping
occurs, your fireplace could pro­duce increased levels of carbon monoxide. If burner flame pat­tern shows yellow tipping, follow instructions in column 2 of this page.
Thermocouple
Thermocouple
NOTICE: Do not mistake orange flames with yellow tipping. Dirt or other fine particles enter the fireplace and burn causing brief patches of orange flame.
If burner flame pattern is incorrect, as shown in Figure 30
• turn fireplace off (see T o T urn Off Gas to Appliance, page 15).
• see Troubleshooting, pages 17 through 19.
Top of Flame About One Inch Above Charred Area
CORRECT FLAME PATTERN
AT HIGH POSITION
Figure 29 - Correct Burner Flame Pattern
Yellow Tipping
INCORRECT FLAME PATTERN
AT HIGH POSITION
Figure 30 - Incorrect Burner Flame Pattern
CLEANING AND MAINTENANCE
WARNING: Turn off fireplace
and let cool before cleaning.
CAUTION: You must keep con­trol areas, burner, and circulating air passageways of fireplace clean. Inspect these areas of fire­place before each use. Have fire­place inspected yearly by a quali­fied service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, pet hair, etc.
ODS/PILOT AND BURNER
• Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean.
CABINET
Air Passageways
• Use a vacuum cleaner or pressurized air to clean.
Exterior
• Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabi­net to remove dust.
REPLACEMENT PARTS
Note:
Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product. If they can’t supply original replacement part(s) call DESA International’s Technical Service Department at 1-800-323-5190 for referral information.
When calling DESA International, have ready
• your name
• your address
• model number of your fireplace
• how fireplace was malfunctioning
• type of gas used (propane/LP or natural
gas)
• purchase date Usually, we will ask you to return the defec-
tive part to the factory.
PARTS NOT UNDER WARRANTY
Contact authorized dealers of this product or Parts Central (see page 20). If they can’t supply original replacement part(s) call DESA International’s Parts Department at 1-800-972-7879 for referral information.
When calling DESA International, have ready
• model number of your fireplace
• the replacement part number
16
104326
OWNER’S MANUAL
TROUBLESHOOTING
Note
: All troubleshooting items are listed
in order of operation.
OBSERVED PROBLEM
When ignitor button is pressed, there is no
spark at ODS/pilot
When ignitor button is pressed, there is
spark at ODS/pilot but no ignition
WARNING: Turn off fireplace and let cool before servicing. Only a qualified service person should service and repair fireplace.
POSSIBLE CAUSE
1. Ignitor electrode not connected to igni­tor cable
2. Ignitor cable pinched or wet
3. Piezo ignitor nut is loose
4. Broken ignitor cable
5. Bad piezo ignitor
6. Ignitor electrode broken
7. Ignitor electrode positioned wrong
1. Gas supply turned off or manual shutoff valve closed
2. Control knob not in PILOT position
3. Control knob not pressed in while in PILOT position
4. Air in gas lines when installed
5. Depleted gas supply
6. ODS/pilot is clogged
7. Gas regulator setting is not correct
CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.
REMEDY
1. Reconnect ignitor cable
2. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry
3. Tighten nut holding piezo ignitor to base panel of log set. Nut is located behind base panel.
4. Replace ignitor cable
5. Replace piezo ignitor
6. Replace piezo ignitor
7. Replace piezo ignitor
1. Turn on gas supply or open manual shutoff valve
2. Turn control knob to PILOT position
3. Press in control knob while in PILOT position
4. Continue holding down control knob. Repeat igniting operation until air is re­moved
5. Contact local propane gas company
6. Clean ODS/pilot (see Cleaning and Maintenance, page 16) or replace ODS/ pilot assembly
7. Replace gas control
ODS/pilot lights but flame goes out when
control knob is released
104326
1. Control knob not fully pressed in
2. Control knob not pressed in long enough
3. Manual shutoff valve not fully open
4. Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This prob­lem could be caused by one or both of the following: A) Low gas pressure B) Dirty or partially clogged ODS/pilot
5. Thermocouple connection loose at con­trol valve
6. Thermocouple damaged
7. Control valve damaged
17
1. Press in control knob fully
2. After ODS/pilot lights, keep control knob pressed in 30 seconds
3. Fully open manual shut-off valve
4. A) Contact local propane gas company
B) Clean ODS/pilot (see Cleaning and Maintenance, page 16) or replace ODS/ pilot assembly
5. Hand tighten until snug, then tighten 1/4 turn more
6. Replace thermocouple
7. Replace control valve
Continued
CGCF26NR
VENT-FREE NATURAL GAS COMPACT FIREPLACE
TROUBLESHOOTING
Continued
OBSERVED PROBLEM
Burner does not light after ODS/pilot is lit
Delayed ignition burner
Burner backfiring during combustion
Slight smoke or odor during initial operation
POSSIBLE CAUSE
1. Burner orifice clogged
2. Inlet gas pressure is too low
3. Burner orifice diameter is too small
4. Thermopile leads disconnected or im­properly connected
5. Burners will not come on in remote po­sition
1. Manifold pressure is too low
2. Burner orifice clogged
1. Burner orifice is clogged or damaged
2. Damaged burner
3. Gas regulator defective
1. Not enough air
2. Gas regulator defective
3. Residues from manufacturing processes and logs curing
REMEDY
1. Clean burner (see Cleaning and Mainte­nance, page 16) or replace burner orifice
2. Contact local propane gas company
3. Replace burner orifice
4. Reconnect leads (see Wiring Diagram, page 20)
5. Replace battery in transmitter and re­ceiver
1. Contact local propane gas company
2. Clean burner (see Cleaning and Mainte- nance, page 16) or replace burner orifice
1. Clean burner (see Cleaning and Mainte- nance, page 16) or replace burner orifice
2. Replace damaged burner
3. Replace gas control
1. Check burner for dirt and debris. If found, clean burner (see Cleaning and Maintenance, page 16)
2. Replace gas control
3. Problem will stop after a few hours of operation
Moisture/condensation noticed on windows
Heater produces a whistling noise when
burner is lit
White powder residue forming within burner
box or on adjacent walls or furniture
1. Not enough combustion/ventilation air
1. Turning control knob to HI position when burner is cold
2. Air in gas line
3. Air passageways on heater blocked
4. Dirty or partially clogged burner orifice
1. When heated, vapors from furniture pol­ish, wax, carpet cleaners, etc. turn into white powder residue
1. Refer to Air for Combustion and Venti- lation requirements (page 5)
1. Turn control knob to LO position and let warm up for a minute
2. Operate burner until air is removed from line. Have gas line checked by local pro­pane gas company
3. Observe minimum installation clear­ances (see pages 8 through 10)
4. Clean burner (see Cleaning and Mainte- nance, page 16) or replace burner orifice
1. Turn heater off when using furniture polish, wax, carpet cleaners, or similar products
18
104326
TROUBLESHOOTING
Continued
WARNING: If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
OWNER’S MANUAL
IMPORTANT:
supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.
Operating heater where impurities in air exist may create odors. Cleaning
OBSERVED PROBLEM
Heater produces a clicking/ticking noise
just after burner is lit or shut off
Heater produces unwanted odors
Heater shuts off in use (ODS operates)
Gas odor even when control knob is in OFF
position
POSSIBLE CAUSE
1. Metal expanding while heating or con­tracting while cooling
1. Heater burning vapors from paint, hair spray, glues, cleaners, chemicals, new carpet, etc. (See ment above)
2. Gas leak. See W arning statement at
top of page
1. Not enough fresh air is available
2. Low line pressure
3. ODS/pilot is partially clogged
1. Gas leak. See W arning statement at
top of page
2. Control valve defective
IMPORTANT
state-
REMEDY
1. This is common with most heaters. If noise is excessive, contact qualified ser­vice person
1. Open window and ventilate room. Stop using odor causing products while heater is running
2. Locate and correct all leaks (see Check- ing Gas Connections, page 13)
1. Open window and/or door for ventilation
2. Contact local natural gas company
3. Clean ODS/pilot (see Cleaning and Maintenance, page 16)
1. Locate and correct all leaks (see Check- ing Gas Connections, page 13)
2. Replace control valve
Gas odor during combustion
104326
1. Foreign matter between control valve and burner
2. Gas leak. See W arning statement at
top of page
19
1. Take apart gas tubing and remove for­eign matter
2. Locate and correct all leaks (see Check- ing Gas Connections, page 13)
CGCF26NR
VENT-FREE NATURAL GAS COMPACT FIREPLACE
SPECIFICATIONS
Btu (Variable) 15,000/26,000 Type Gas Natural Only Ignition Piezo Manifold Pressure 3.5" W.C. Inlet Gas Pressure
(in. of water) *
Maximum 10.5" Minimum 5"
Dimensions, Inches (H x W x D)
Fireplace 257/8 x 2613/16 x 93/8 Carton 325/8 x 273/16 x 115/8
Weight, pounds
Fireplace 441/2 lbs. Shipping 48 lbs.
* For purposes of input adjustment
PARTS CENTRALS
Baltimore Electric
1348 Dixwell Avenue Hamden, CT 06514-0322 1-800-397-7553 203-248-7553 Parts Department
Portable Heater Parts
342 N. County Rd. 400 East Valparaiso, IN 46383-9704 All States 219-462-7441 1-800-362-6951 Parts Department
FBD
1349 Adams St. Bowling Green, KY 42103-3413 502-846-1199 1-800-654-8534 Fax: 1-800-846-0090
Four Flags Power Products
1115 Stateline Road Niles, MI 49120-4728 616-684-2697 1-800-268-4983 Parts Only
SERVICE HINTS
When gas pressure is too low
• pilot will not stay lit
• burner will have delayed ignition
• fireplace will not produce specified heat
When gas quality is bad
• pilot will not stay lit
• burner will produce flames and soot
• fireplace will backfire when lit You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local natural gas supplier.
These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories.
Master Parts Distributors
1184 Wilson Ave. NW Grand Rapids, MI 49504-3458 616-791-0505 Fax: 1-616-791-8270 Parts Department 1-800-446-1446
Washer Equipment Co.
1715 Main Street Kansas City, MO 64108-2195 KS, MO, AR 816-842-3911 Parts Department
East Coast Energy Products
707 Broadway W. Long Branch, NJ 07764-1542 908-870-8809 1-800-755-8809 Parts Department
Tarantin Tank Co.
P.O. Box 6129 Freehold, NJ 07728-6129 908-780-9340 1-800-922-0724 Parts Department
Heater & Fireplace Store
1922 N Route 9 Cape May Court, NJ 0820-1110 609-624-0678 Parts Department
TECHNICAL SERVICE
You may have further questions about in­stallation, operation, or troubleshooting.
If so, contact DESA International’s Technical Service Department at 1-800-323-5190.
WIRING DIAGRAM
On
Receiver
Off
Remote
Thermopile
Dayton Hardware
P.O. Box 275 North Dayton Station Dayton, OH 45404-0275 All States 513-258-3721 Parts Department 1-800-762-3426
Halco Enterprises
208 Carter Drive, Unit 21 West Chester, PA 19382-4500 610-430-7717 1-800-368-0803 Parts Department
LaPorte’s Parts & Service
2444 North 5th Street Hartsville, SC 29550-7704 803-332-0191 Parts Department
Cans Unlimited, Inc.
P.O. Box 645 Taylor, SC 29687-0013 All States 803-879-3009 1-800-845-5301 Parts Department
Black
Red
Red
White
TPTH TH
Gas Control
TPTH
TP
20
104326
OWNER’S MANUAL
ACCESSORIES
Purchase these fireplace accessories from your local dealer. If they cannot supply these accessories call DESA International’s Sales Department at 1-800-458-2472 for referral information. You can also write to the address listed on the back page of this manual.
MANUAL SHUTOFF VALVE ­GA5010
Manual shutoff valve with 1/8" NPT tap.
THERMOSTATICALLY CONTROLLED BLOWER KIT ­GA3450T
Provides better heat distribution. Blower turns off and on automatically, as needed. Complete installation and operating instruc­tions included.
CABINET MANTEL WITH BUILT-IN HEARTH BASE
Unfinished Hardwood Veneer­GMC16U
Walnut Finished Hardwood Veneer- GMC15F
Medium Stained Oak Veneer­GMC17F
For use with fireplace. A hardwood mantel and hearth base offers compact styling and completes the fireplace look. Available in a walnut stain, medium oak stain, or an unfin­ished hardwood, ready to stain or paint. Complete assembly instructions included. Three-sided brass trim kit included.
CORNER MANTEL WITH BUILT-IN HEARTH BASE AND TRADITIONAL SQUARE LEG STYING
Finished Oak Veneer - GMC43F Unfinished Oak Veneer­GMC44U Finished Walnut Hardwood Veneer - GMC38F Unfinished Hardwood Veneer­GMC39U
For use with fireplace. A hardwood mantel and hearth base offers compact styling and completes the fireplace look. Available in a stained or an unfinished (ready to stain or paint) Oak Veneer over hardwood. Com­plete assembly instructions included. Three­sided brass trim kit included.
BRASS TRIM KIT - GA6095
Optional four-sided brass trim kit for built­in installations. Provides a finished appear­ance covering rough edges of wall opening.
104326
CORNER MANTEL WITH BUILT-IN HEARTH BASE
Unfinished Hardwood Veneer­GMC20U
Finished Hardwood Veneer­GMC19F
For use with fireplace. Space-saving mantel and hearth base corner design features clean, classic lines. Available in a walnut finish or an unfinished hardwood, ready to stain or paint. Complete assembly instructions in­cluded. Three-sided brass trim kit included.
21
CGCF26NR
VENT-FREE NATURAL GAS COMPACT FIREPLACE
ILLUSTRATED PARTS BREAKDOWN
CGCF26NR
8
1
3
41
7
23
41
43
4
9
27-1
42
4
10
34
41
41
7
41
25
3
2
35
14
18
4
22
37
36
41
16
24
12
4
42
17
27-2
11
26
32
14
33
31
37
15
11
5
19
29
18
21
38
HI
TEMP
MAN
AUTO
ONLO
OFF
STATUS
22
13
30
39
40
6
20
28
104326
OWNER’S MANUAL
PARTS LIST
CGCF26NR
This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 16 of this manual.
KEY NO. PART NO. DESCRIPTION QTY.
1 102633-02CK Outer Casing Top 1 2 102624-02 Outer Casing 1 3 099230-02 Shoulder Screw 16 4 098304-01 Screw, #10 x 3/8" 19 5 103447-02 Burner 1 6 104230-02 Louvered Door, Service Assembly 1 7 102635-02CK Left and Right Side Front 2 8 103692-01CK Top Louver 1 9 102730-01CJ Firebox Hood 1 10 102638-01 Firebox Top 1 11 103779-01 ODS/Pilot Assembly 1 12 102460-01CJ Firebox Wrapper 1 13 104322-01 Burner Tube 1 14 103823-02 Remote Set (Includes Transmitter) 1 15 104335-01CK Outer Shell Base 1 16 102649-02CJ Branch Support 1 17 097159-04 Piezo 1 18 098271-07 Ignitor Cable 1 19 098251-10 Injector 1 20 098250-01 Injector Holder 1 21 098249-01 Nut, M5 6 22 103781-01 Gas Valve 1 23 102639-01 Baffle 1 24 101628-01 Flexible Connector 1 25 104305-01 Control Shield 1 26 103295-02CJ Screen Assembly 1 27-1 104058-01 Branch 1 27-2 104077-01 Main Log 1 28 101386-02 Hinge 2 29 30 102645-02 Burner Support, Right 1 31 102645-03 Burner Support, Left 1 32 097809-02 Connector, Male 1 33 101629-01 Bushing 1 34 101629-02 Bushing 1 35 M12461-26 Gas Valve Screws 2 36 098264-02 Connector, Male 1 37 103284-03 Wire Harness 1 38 099387-14 Pilot Tube to Regulator 1 39 099918-02 Regulator Pilot 1 40 099387-15 Pilot Tube, Regulator to Control Valve 1 41 M11084-26 Hex Head Screws #10 x .38 30 42 097403-02 Pan Head Screws 1 43 102458-01CK Middle Rail 1
099194-11
PARTS AVAILABLE — NOT SHOWN
Rivets 8
3
/4"2
104326
103877-01 Lighting Instructions Plate 1 100563-01 Warning Plate 1 103470-01 Hardware Package 1 104319-01 Information Video 1
23
WARRANTY INFORMATION
KEEP THIS WARRANTY
Model Serial No. Date Purchased
Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written
warranty. We make no other warranty, expressed or implied.
LIMITED WARRANTY
VENT-FREE NATURAL GAS COMPACT FIREPLACE
DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this fireplace to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The fireplace MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTA­BILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state. For information about this warranty write:
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004
104326 01
NOT A UPC
104326-01 REV. C
08/98
Loading...