Desa CGB3930PR, CGD3924PR, CGB3924PR User Manual

Page 1
PREMIUM AGED SPLIT OAK
P
I
L
O
T
O
F
F
O
N
LO
REMOTE
OFF
HI
AND YELLOW FLAME UNVENTED (VENT-FREE)
PROPANE/LP GAS LOG HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
Remote Control
CGD3924PR CGB3924PR CGB3930PR
24" and 30" Remote
Controlled Models
(Yellow Flame Model Shown)
Operation Requires Two (2) 9-Volt Alkaline Batteries Not Included
®
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, per­sonal injury, or loss of life.
WARNING: Improper installation, adjust­ment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual for correct installa­tion and operational procedures. For
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of this or any other appliance.
assistance or additional information con­sult a qualified installer, service agency, or the gas supplier.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
Installation and service must be per-
formed by a qualified installer, service agency, or the gas supplier.
WARNING: This appliance is for instal­lation only in a solid-fuel burning ma­sonry or UL127 factory-built fireplace, or in an approved ventless firebox. It is design certified for these installations in accordance with ANSI Z21.11.2. Exception: Do not install this appliance in a factory-built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs.
WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to
Air for Combustion and Ventilation
section on page 4 of this manual.
This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
Save this manual for future reference.
Page 2
CGD3924PR, CGB3924PR and CGB3930PR
UNVENTED PROPANE/LP GAS LOG HEATER
SAFETY INFORMATION
WARNINGS
IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, oper­ate, or service this heater. Im­proper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.
DANGER: Carbon monoxide
poisoning may lead to death!
Carbon Monoxide Poisoning: Early
signs of carbon monoxide poisoning re­semble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.
Propane Gas: Propane gas is odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. How­ever, the odor added to the gas can fade. Gas may be present even though no odor exists.
Make certain you read and understand all Warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.
WARNING: Any change to this heater or its controls can be dangerous.
1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
2. Do not place propane supply tank(s) inside any structure. Locate propane supply tank(s) outdoors.
3. If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do
not use any phone in your building
• immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions
• if you cannot reach your gas supplier, call the fire department
4. This heater shall not be installed in a bedroom or bathroom.
5. Never install the heater
• in a recreational vehicle
• where curtains, furniture, clothing, or
other flammable objects are less than 36 inches from the front, top, or sides of the heater
• in high traffic areas
• in windy or drafty areas
6. Before installing in a solid fuel burn­ing fireplace, the chimney flue and fire­box must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. Inspect chimney flue for damage. If damaged, operate heater with flue damper closed.
7. If fireplace has glass doors, never op­erate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace open­ing has vents at the bottom, you must open the vents before operating heater.
8. You must operate this heater with a fire­place screen in place. Make sure fireplace screen is closed before running heater.
9. This log heater is designed to be smoke­less. If logs ever appear to smoke, turn off heater and call a qualified service per­son.
Note:
During initial operation, slight smoking may occur due to log curing and heater burning manufacturing residues.
10. Do not allow fans to blow directly into the fireplace. Avoid any drafts that al­ter burner flame patterns. Ceiling fans may create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.
11. Before using furniture polish, wax, car­pet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white pow­der residue within burner box or on adjacent walls or furniture.
12. Do not use a blower insert, heat ex­changer insert or other accessory not approved for use with this heater.
13. This heater needs fresh, outside air ven­tilation to run properly . This heater has an oxygen depletion sensor (ODS) pi­lot light safety system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 4 through 6. If heater keeps shutting off, see Trouble- shooting, pages 18 through 20.
14. Do not run heater
• where flammable liquids or vapors
are used or stored
• under dusty conditions
15. Do not use this heater to cook food or burn paper or other objects.
16. Never place any objects on the heater.
17. Heater base assembly becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shutpdown. Allow surface to cool before touching.
18. Carefully supervise young children when they are in the room with heater. When using the hand-held remote ac­cessory, keep remote selector switch in the OFF position to prevent children from turning on burners with hand-held remote control unit.
19. Do not use heater if any part has been exposed to or under water. Immediately call a qualified service technician to in­spect the room heater and to replace any part of the control system and any gas control which has been under water.
20. Do not operate heater if any log is bro­ken. Do not operate heater if a log is chipped (dime-sized or larger).
21. Turn heater off and let cool before ser­vicing, installing, or repairing. Make sure the remote selector switch is in the OFF position. Only a qualified service person should install, service, or repair heater.
22. Make sure the remote selector switch is in the OFF position when you are away from home for long periods of time.
23. This heater must not be connected to any external electrical source.
24. Operating heater above elevations of 4,500 feet may cause pilot outage.
25. T o prevent performance problems, the use of a propane fuel tank of less than 100 lb. capacity is not recommended.
2
104307
Page 3
OWNER’S MANUAL
PRODUCT IDENTIFICATION
Crossover Log
Front Log
Remote Control
HI
TEMP
MAN
AUTO
ONLO
OFF
STATUS
Piezo Ignitor
Figure 1 - Vent-Free Gas Log Heater (Logs May Vary By Model)
Remote Selector Switch
Flame Adjustment Knob
Control Knob
Back Log
Middle Log
Base Grate
Burner
PRODUCT FEATURES
Operation
This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by realistic dancing, yellow flames. This heater is designed for vent-free operation with flue damper closed. State and local codes in some areas prohibit the use of vent-free heaters.
Safety Pilot
This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent­free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.
Piezo Ignition System
This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.
LOCAL CODES
Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223, also known as NFPA 54*.
*Available from: American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
UNPACKING
1. Remove logs and heater base assem­bly from carton. heater base assembly by burners. This could damage heater. Always handle base assembly by grate.
2. Remove all protective packaging ap­plied to logs and heater for shipment.
3. Check all items for any shipping dam­age. If damaged, promptly inform dealer where you bought heater.
Note:
Do not pick up
104307
3
Page 4
CGD3924PR, CGB3924PR and CGB3930PR
UNVENTED PROPANE/LP GAS LOG HEATER
AIR FOR COMBUSTION AND VENTILATION
WARNING: This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ven­tilation air. Read the following in­structions to insure proper fresh air for this and other fuel-burning appliances in your home.
Today’s homes are built more energy effi­cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.
While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper com­bustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide ad­equate fresh air for these appliances. This will insure proper venting of vented fuel­burning appliances.
Unusually Tight Construction
The air that leaks around doors and win­dows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.
Unusually tight construction is de­fined as construction where:
a. walls and ceilings e xposed to the
outside atmosphere have a con­tinuous water vapor retarder with a rating of one perm (6 x 10 per pa-sec-m2) or less with open­ings gasketed or sealed
b. weather stripping has been
added on openable windows and doors
c. caulking or sealants are applied
to areas such as joints around window and door frames, be­tween sole plates and floors, be­tween wall-ceiling joints, be­tween wall panels, at penetra­tions for plumbing, electrical, and gas lines, and at other openings.
If your home meets all of the three criteria above, you must provide ad­ditional fresh air. See
From Outdoors
If your home does not meet all of the three criteria above, proceed to
and
Ventilation Air
, page 6.
termining Fresh-Air Flow For Heater Location
, page 5.
and
-11
kg
De-
Confined Space and Unconfined Space
The National Fuel Gas Code (ANSI Z2123.1, 1992 Section 5.3) defines a confined space
as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are in­stalled*, through openings not furnished with doors, are considered a part of the unconfined space.
This heater shall not be installed in a con­fined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.
* Adjoining rooms are communicating only if there are doorless passageways or ventila­tion grills between them.
PROVIDING ADEQUATE VENTILATION
The following is exerpts from National Fuel Gas Code. NFPA 54/ANSI Z223.1, Section
5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three following ventilation classifications:
1. Unusually Tight Contruction
2. Unconfined Space
3. Confined Space The information on pages 4 through 6 will
help you classify your space and provide adequate ventilation.
4
104307
Page 5
OWNER’S MANUAL
AIR FOR COMBUSTION AND VENTILATION
Continued
DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION
Determining if You Have a Confined or Unconfined Space
Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between
the rooms.
1. Determine the volume of the space (length x width x height). Length x Width x Height = _________________cu. ft. (volume of space)
Example:
If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.
2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.
_________________ (volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support)
Example:
3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free heater __________________Btu/Hr Gas water heater* __________________Btu/Hr Gas furnace __________________Btu/Hr Vented gas heater __________________Btu/Hr Gas fireplace logs __________________Btu/Hr Other gas appliances* + __________________Btu/Hr Total = __________________Btu/Hr * Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.
4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
_____________________Btu/Hr (maximum the space can support) _____________________Btu/Hr (actual amount of Btu/Hr used)
Example:
The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:
A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin-
ing room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 6.
B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 6. C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.
Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)
2560 cu. ft. (volume of space) ÷ 50 cu. ft. = 51.2 or 51,200 (maximum Btu/Hr the space can support)
Example:
Gas water heater Vent-free heater + Total =
51,200 Btu/Hr (maximum the space can support)
79,000 Btu/Hr (actual amount of Btu/Hr used)
40,000 39,000 79,000
Btu/Hr Btu/Hr Btu/Hr
WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the
104307
National Fuel Gas Code, ANSI Z223.1, 1992, Section 5.3
5
or applicable local codes.
Continued
Page 6
CGD3924PR, CGB3924PR and CGB3930PR
UNVENTED PROPANE/LP GAS LOG HEATER
AIR FOR COMBUSTION AND VENTILATION
Continued
VENTILATION AIR
Ventilation Air From Inside Building
This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro­vide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see op­tion 3, Figure 2). Follow the National Fuel
Gas Code NFPA 54/ANSI Z223.1, Section
5.3, Air for Combustion and Ventilation for
required size of ventilation grills or ducts.
WARNING: Rework work­sheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces.
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or ducts. You must provide two per­manent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces.
IMPORTANT:
inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.
Do not provide openings for
Ventilation
Grills
Into Adjoining
Room,
Option 1
Figure 2 - Ventilation Air from Inside Building
Or
Remove Door into Adjoining
Room, Option
3
12"
Outlet Air
Ventilation Grills
Into Adjoining Room,
Ventilated Attic
Outlet Air
Inlet Air
Inlet Air
Figure 3 - Ventilation Air from Outdoors
12"
Option 2
To Attic
To
Crawl
Space
Ventilated
Crawl Space
6
104307
Page 7
OWNER’S MANUAL
INSTALLATION
NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri­mary heating system. Do not in­stall this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circu­late the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.
NOTICE: A qualified service per­son must install heater. Follow all local codes.
NOTICE: State or local codes may only allow operation of this appli­ance in a vented configuration. Check your state or local codes.
WARNING: Make sure the re­mote selector switch is in the OFF position before installing heater.
WARNING: Never install the
heater
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater
• in high traffic areas
• in windy or drafty areas
CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls.
IMPORTANT:
ture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Com- bustion and Ventilation, pages 4 through 6.
Vent-free heaters add mois-
LOG SIZING REQUIREMENTS
Minimum Firebox Size
Rear
Width
Log Front At 14"
Size Height Depth Width Depth
24" 17" 14" 28" 21" 30" 17" 14" 34" 24"
Carefully follow the instructions below. This will ensure safe installation into a masonry fireplace or factory-built U.L. 127 listed vent-free firebox.
Minimum Wall and Ceiling Clearances (see Figure 4)
A. Clearances from the side of the fire-
place opening to any combustible wall should not be less than 16 inches.
B. Clearances from the top of the fireplace
opening to the ceiling should not be less than 42 inches.
42"
WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a quali­fied chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and dis­tribute soot within the house. In­spect chimney flue for damage. If damaged, operate heater with flue damper closed.
WARNING: Seal any fresh air vents or ash clean-out doors lo­cated on floor or wall of fireplace. If not, drafting may cause pilot outage or sooting. Use a heat­resistant sealant. Do not seal chimney flue damper.
104307
CHECK GAS TYPE
Use only propane/LP gas. If your gas supply is not propane/LP gas, do not install heater. Call dealer where you bought heater for proper type heater.
INSTALLATION AND CLEARANCES (Vent-Free Operation Only)
WARNING: Maintain the mini­mum clearances. If you can, pro­vide greater clearances from floor, ceiling, and adjoining wall.
MINIMUM FIREPLACE
CLEARANCE TO
COMBUSTIBLE MATERIALS
Log Size Side Wall Ceiling
24" 16" 42"
7
16"
Left and
Right Sides
Figure 4 - Minimum Clearance to Wall and Ceiling
Continued
Page 8
CGD3924PR, CGB3924PR and CGB3930PR
UNVENTED PROPANE/LP GAS LOG HEATER
INSTALLATION
Continued
Minimum Non-Combustible Material Clearances
If Not Using Mantel
Note:
If using a mantel, proceed to If Using
Mantel. If not using a mantel, follow the
information below. You must have non-combustible material(s)
above the fireplace opening. Non-combus­tible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have non-combus­tible material behind it. Non-combustible material must extend at least 8" up (for all models). If non-combustible material is less than 12", you must install the fireplace hood accessory (24" and 30" models only). See Figure 5 for minimum clearances.
IMPORTANT:
minimum clearances, you must operate heater with chimney flue damper open.
If Using Mantel
You must have non-combustible material(s) above the fireplace opening. Non-combus­tible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have non-combus­tible material behind it. Non-combustible material must extend at least 8 inches up (for all models). If non-combustible material is less than 12", you must install the fireplace hood accessory (24" and 30" models only). Even if non-combustible material is more than 12", you may need the hood accessory to deflect heat away from your mantel shelf. See Figure 5 and Figures 6 and 7on page 9 for minimum clearances.
IMPORTANT:
minimum clearances, you must operate heater with chimney flue damper open.
If you cannot meet these
If you cannot meet these
Non-Combustible Requirements for Material Distance (A) Safe Installation
12" or more Non-combustible material okay. Between 8" and 12" Install fireplace hood accessory (GA6050, GA6052,
or GA6053, see
Less than 8" Non-combustible material must be extended to at
least 8". See cannot extend material, you must operate heater with flue damper open.
Accessories,
Between 8" and 12",
page 21).
above. If you
Heat Resistant Material
(A)
Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace
8
104307
Page 9
OWNER’S MANUAL
Hearth
5" Min.
Combustible Material
INSTALLATION
Continued
MANTEL CLEARANCES
If you meet minimum clearance between mantel shelf and top of fireplace opening, a hood is not required (see Figure 6).
If minimum clearances in Figure 6 are not met, you must have a hood. When using a hood there are still certain minimum mantel clearances required. Follow minimum clear­ances shown in Figure 7 when using hood.
NOTICE: If your installation does not meet the minimum clearances shown, you must do one of the following:
• operate the logs only with the flue damper open
• raise the mantel to an accept­able height
• remove the mantel.
Floor Clearances
A. If installing appliance on the floor level,
you must maintain the minimum dis­tance of 14" to combustibles (see Fig­ure 8).
B. If combustible materials are less than
14" to the fireplace, you must install appliance at least 5" above the combus­tible flooring (see Figure 9).
Mantel Shelf
18" 20" 22" 24"
Distances to Underside of Mantel
Underside of Mantel Shelf
All minimum distances are in inches
Log Set
24"/30" Models
Top of Fireplace Opening
Minimum Non­Combustible Material
10" 8" 6"
1
2
"
/2
(A)
12"
Minimum Non­Combustible Material Height
Figure 6 - Minimum Mantel Clearances Without Using Hood
8" Min.
Mantel Shelf
12" 15" 18"
Distances to Underside of Mantel
Underside of Mantel Shelf
All minimum distances are in inches
Log Set
18", 24", 30"
20"
All Models
Models
Top of Fireplace Opening
Minimum Non­Combustible Material
12" 10" 8" 6"
1
"
/2
2
Hood (GA6050, GA6052)
104307
Figure 7 - Minimum Mantel Clearances When Using Hood
Combustible
Combustible
Material
14"
14" Min.
Min.
Non-Combustible Material
Non-Combustible
Material
Material
Figure 9 - Minimum Fireplace Clearances
Figure 8 - Minimum Fireplace Clearances
Above Combustible Flooring
If Installed at Floor Level
9
Hearth
Combustible Material
5" Min.
Continued
Page 10
CGD3924PR, CGB3924PR and CGB3930PR
UNVENTED PROPANE/LP GAS LOG HEATER
INSTALLATION
Continued
INSTALLING HEATER BASE ASSEMBLY
CAUTION: Do not remove the metal data plates attached to the heater base assembly. The data plates contain important warranty information.
WARNING: You must secure this heater to fireplace floor. If not, heater will move when you adjust controls. Moving heater may cause a gas leak.
WARNING: If installing in a sunken fireplace, special care is needed. You must raise the fire­place floor to allow access to heater control panel. This will in­sure adequate air flow and guard against sooting. Raise fireplace floor with non-combustible mate­rial. Make sure material is secure.
CAUTION: Do not pick up heater base assembly by the burner. This could damage heater. Only handle base assem­bly by grates.
IMPORTANT:
ers are level. If heater is not level, heater will not work properly.
Make sure the heater burn-
4. Mark screw locations through holes in mounting flanges (see Figure 11). If in­stalling in a brick-bottom fireplace, mark screw locations in mortar joint of bricks.
5. Remove heater base from fireplace.
6. Drill holes at marked locations using 3/16" masonry drill bit.
7. Attach base assembly to fireplace floor using two masonry screws (in hardware package) (see Figure 11).
8. Connect to gas supply. See Connect- ing To Gas Supply.
Flexible Gas Hose (if allowed by local codes)
Fitting
Figure 10 - Attaching Flexible Gas Hose to Heater
Masonry Screw
Mounting Flanges
Installation Items Needed
Before installing heater, make sure you have the items listed below.
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• manual shutoff valve *
• test gauge connection *
• sediment trap
• tee joint
• pipe wrench
• two (2) 9-volt alkaline batteries (not in­cluded)
* An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Pur­chase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 21.
The installer must supply an external regu­lator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incom­ing gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure
12. Pointing the vent down protects it from
freezing rain or sleet.
External Regulator Propane Supply Tank
Installation Items Needed
• hardware package (provided with heater)
• approved flexible gas hose (not provided) (if allowed by local codes)
• sealant resistant to propane/LP gas, not provided
• electric drill with 3/16" masonry drill bit
1. Apply pipe joint sealant lightly to male
threads of the fitting to be threaded into gas regulator. Connect approved flex­ible gas hose to gas regulator of heater (see Figure 10).
2. Locate masonary screws in hardware
package.
3. Position heater base assembly in
fireplace.
Figure 11 - Attaching Base Assembly to Fireplace Floor
CONNECTING TO GAS SUPPLY
NOTICE: A qualified service per­son must connect heater to gas supply. Follow all local codes.
CAUTION: Never connect heater directly to the propane supply. This heater requires an external regulator (not supplied). Install the external regulator be­tween the heater and propane supply.
10
Vent Pointing Down
Figure 12 - External Regulator With Vent Pointing Down
104307
Page 11
OWNER’S MANUAL
INSTALLATION
Continued
CAUTION: Use only new, black iron or steel pipe. Inter­nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.
Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 13).
Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
CAUTION: Use pipe joint seal­ant that is resistant to liquid pe­troleum (LP) gas.
A.G.A. Design-Certified Manual Shutoff Valve With 1/8" NPT Tap*
Approved Flexible Gas Hose (if allowed by local codes)
Gas Control
Install sediment trap in supply line as shown in Figure 13. Locate sediment trap where it is within reach for cleaning. Locate sedi­ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.
CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings.
CHECKING GAS CONNECTIONS
WARNING: Test all gas pip­ing and connections for leaks after installing or servicing. Cor­rect all leaks at once.
WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.
From Propane Tank (11" W.C.** to 14" W.C. Pressure)
Tee Joint
3" Minimum
Pipe
Nipple
Cap
CAUTION: Make sure exter­nal regulator has been installed between propane supply and heater. See guidelines under
necting to Gas Supply
Con-
, page 10.
Pressure Testing gas Supply Piping system
Test Pressures In Excess Of 1/2 PSIG
1. Disconnect heater and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator.
2. Cap off open end of gas pipe where manual shutoff valve was connected.
3. Pressurize supply piping system by ei­ther using compressed air or opening propane supply tank valve.
4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles form­ing show a leak.
5. Correct all leaks at once.
6. Re-connect heater and manual shutoff valve to gas supply. Check re-con­nected fittings for leaks.
Test Pressures Equal To or Less Than 1/2 PSIG
1. Close manual shutoff valve (see Fig­ure 14, page 12).
2. Pressurize supply piping system by ei­ther using compressed air or opening propane supply tank valve.
3. Check all joints from propane supply tank to manual shutoff valve (see Fig­ure 15, page 12). Apply mixture of liq­uid soap and water to gas joints. Bubbles forming show a leak.
4. Correct all leaks at once.
Sediment Trap
Figure 13 - Gas Connection
* Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 21.
** Minimum inlet pressure for purpose of input adjustment.
104307
11
Continued
Page 12
CGD3924PR, CGB3924PR and CGB3930PR
UNVENTED PROPANE/LP GAS LOG HEATER
INSTALLATION
Continued
Pressure Testing Heater Gas Connections
1. Open manual shutoff valve (see Fig­ure 14).
2. Open propane supply tank valve.
3. Make sure control knob of heater is in the OFF position.
Manual Shutoff Valve
Figure 14 - Manual Shutoff Valve
Propane Tank
ON
Open
POSITION
OFF
POSITION
Closed
Manual Shutoff Valve
4. Check all joints from manual shutoff valve to control valve (see Figure 15). Apply mixture of liquid soap and wa­ter to gas joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light heater (see Operating Heater, pages 15 through 17). Check all other internal joints for leaks.
7. Turn off heater (see To Turn Off Gas to Appliance, page 16).
Thermostat Gas Valve or Control Valve Location
9-VOLT BATTERY INSTALLATION
Two 9-volt alkaline batteries (not included) are required to operate this heater with the wireless hand-held remote control set. One battery must be installed in the receiver and one in the hand-held remote control unit.
Note:
Only use alkaline batteries.
Installing 9-Volt Alkaline Battery In Receiver
1. Locate back of receiver under front burner of heater.
2. Locate the battery clip mounted on the back of the receiver.
3. Slide a 9-volt alkaline battery through the clip.
4. Attach the teminal wires to the battery.
Receiver
Figure 15 - Checking Gas Joints
Terminal Wires
9-Volt Battery
Figure 16 - Installing 9-Volt Battery In Receiver
Installing 9-Volt Battery In Hand­Held Remote Control Unit
1. Remove battery cover on back of re­mote control unit.
2. Attack terminal wires to the battery. Place battery into the battery housing.
3. Replace battery cover onto remote con­trol unit.
Battery Cover
Terminal Wires
9-Volt Battery
Figure 17 - Installing Battery In Hand­Held Remote control Unit
Remote Control Unit
Battery Housing
12
104307
Page 13
OWNER’S MANUAL
3
INSTALLATION
Continued
INSTALLING LOGS (CGD3924PR)
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.
CAUTION: After installation and periodically thereafter, check to ensure that no flame comes in contact with any log. If so, repo­sition logs according to the log installation instructions in this manual. Flames contacting logs will create soot.
Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.
1. Locate pegs on the bottom of back log (#1). Slide these pegs into the holes in the grate base behind the burner (see Figure 18).
2. Place the base of the middle log (#2) in the U-shaped slots of the grate base in front of the back log. The cutout on the right of the middle log should fit over the burner (see Figure 19). Make sure the front of the middle log is resting on the tabs of the grate base and the cutout area is centered over the burner “U” bend.
3. Locate the recesses on the back of the front log (#3). Fit these recesses be­tween the posts of the grate base (see Figure 20).
4. Locate the notches in the bottom of the crossover log (#4). Place the crossover log on top of the middle log and front log. Make sure the notches of the cross­over log lines up with rectangular knobs on top of the middle and front logs (see Figure 21).
5. Add lava rock around base of heater. Do not place any lava rock on logs or burner.
Back Log (#1)
Peg
Hole in Grate Base
Burner
Figure 18 - Installing Back Log (#1)
Middle Log (#2)
Tab
Burner
Cutout
“U” Bend
U-Shaped Slot
Figure 19 - Installing Middle Log (#2)
Front Log (#3)
Post
Post
Figure 20 - Installing Front Log (#3)
Notches
Rectangular Knobs
Figure 21 - Installing Crossover Log (#4)
Crossover Log (#1)
Recess
Continued
104307
13
Page 14
CGD3924PR, CGB3924PR and CGB3930PR
UNVENTED PROPANE/LP GAS LOG HEATER
INSTALLATION
Continued
INSTALLING LOGS ON MODELS CGB3924PR AND CGB3930PR
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.
CAUTION: After installation and periodically thereafter, check to ensure that no flame comes in contact with any log. If so, repo­sition logs according to the log installation instructions in this manual. Flames contacting logs will create soot.
Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.
1. Place the base of the middle log (#1) in the U-shaped slots of the grate base. The cutout on the right of the middle log should bit over the burner (see Fig­ure 22). Make sure the front of the middle log is resting on the tabs of the grate base and the cutout area is cen­tered over the burner “U” bend.
2. Locate pegs on the bottom of back log (#2). Slide these pegs into the holes in the grate base behind the burner (see Figure 23).
3. Place crossover log (#3) onto the pin (right) on middle log (#1) and into the recess of the back log (#2) (see Fig­ure 24).
Back Log (#2)
Hole in Grate Base
Peg
Burner
4. Locate the notches in the bottom of the front log (#4). Place the front log on the grate fingers. Make sure the notches of the front log line up with the grate fingers (see Figure 25).
5. With knot to right side, place smaller log piece (#5) over the pin on the lift side of the middle log. The smaller log will rest on front log against the “knot” on the left (see Figure 26).
6. Add lava rock around base of heater. Do not place any lava rock on logs or burner.
Front Log (#4)
Notches
Grate Fingers
Figure 25 - Installing Front Log (#4)
Middle Log (#1)
Tab
Burner
“U” Bend
U-Shaped Slot
Figure 22 - Installing Middle Log (#1)
Figure 23 - Installing Back Log (#2)
Crossover Log (#3)
Recess
Peg
Figure 24 - Installing Crossover Log (#3)
14
Log Piece (#5)
Peg
Figure 26 - Installing Log Piece (#5)
104307
Page 15
OWNER’S MANUAL
OPERATING HEATER
FOR YOUR SAFETY
READ BEFORE
LIGHTING
WARNING: If you do not fol­low these instructions exactly, a fire or explosion may result caus­ing property damage, personal injury or loss of life.
A. This appliance has a pilot which must
be lighted by hand. When lighting the pilot, follow these instructions exactly .
B. BEFORE LIGHTING smell all
around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas sup­plier, call the fire department.
C. Use only your hand to push in or turn
the gas control knob. Ne ver use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part
has been under water . Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas con­trol which has been under water.
LIGHTING
INSTRUCTIONS
WARNING:
• If fireplace has glass doors, never operate this heater with glass doors closed. If you oper­ate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater.
• You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.
NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Orange flame will also be present. Open damper or window to vent smell. This will only last a few hours.
Note:
Homeowners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However there may be times you will desire the full flames of the Hi heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat.
WARNING: Damper handle will be hot if heater has been running.
1. STOP! Read the safety information above.
2. Make sure manual shutoff valve is fully open.
3. Set remote selector switch in the OFF position.
Flame Adjustment Knob
WARNING: Burners will come on automatically within one minute when the remote selector switch is in the ON position after the pilot is lit.
4. Press in and turn control knob clock­wise to the OFF position.
5. Wait f ive (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in­formation above. If you don’t smell gas, go to the next step.
6. Press in and turn control knob coun­terclockwise to the PILOT position. Press in control knob for five (5) seconds (see above).
Note:
You may be running this heater for the first time after hook­ing up to gas supply. If so, the con­trol knob may need to be pressed in for 30 seconds or more. This will al­low air to bleed from the gas system.
7. With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep press­ing ignitor button until pilot lights.
Note:
If pilot does not stay lit, con­tact a qualified service person or gas supplier for repairs. Until repair s are made, light pilot with match. T o light pilot with match, see Manual Light- ing Procedure on page 16.
8. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
• If control knob does not pop out
when released, contact a qualified service person or gas supplier for repairs.
Note:
If pilot goes out, repeat steps
4 through 8.
Control Knob
104307
I
REMOTE OFF ON
Ignitor Button
Figure 27 - Control Knob and Ignitor Button Location
15
Selector Switch in OFF Position
H
L
O
O
F
F
N
P
O
I
L
O
T
Continued
Page 16
CGD3924PR, CGB3924PR and CGB3930PR
UNVENTED PROPANE/LP GAS LOG HEATER
OPERATING HEATER
Continued
9. Slightly push in and turn control knob counterclockwise to the ON position.
10. Wait one minute and switch remote selector switch to the ON position to light burner.
11. Set flame adjustment knob to any level between HI and LO.
Pilot Burner
Figure 27- Pilot
CAUTION: Do not try to adjust heating levels by using the manual shutoff valve.
WARNING: Make sure the re­mote selector switch is in the OFF position when you are away from home for long periods of time. Heater will come on auto­matically with remote selector switch in the ON position.
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
1. T urn control knob clockwise to the OFF position.
2. Set remote selector switch in the OFF position to prevent draining battery.
Ignitor Electrode
THERMOSTAT
CONTROL
OPERATION
The thermostat control setting on the remote control unit can be set to any comfort level between HI and LO. The Burners will turn on and off automati­cally to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 6 under Light­ing Instructions, page 15 and 16.
2. Depress control knob and light pilot with match.
3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 9, column 1.
HAND HELD REMOTE
OPERATION
NOTICE: You must light the pilot before using the hand-held re­mote control unit. See
Instructions
on page 15.
1. After lighting, let pilot flame burn for about one minute. T ur n control knob to ON position. Adjust flame adjust­ment knob anywhere between HI and LO. Slide the remote selector switch to the REMOTE position. The burners will come on. You can now turn the burners on and off with the hand-held remote control unit.
Lighting
IMPORTANT:
Do not leave the re­mote selector switch in the REMOTE position when the pilot is not lit. This will drain the battery.
2. Select the MANUAL or AUT O button on the hand-held remote control unit.
• In MANUAL mode, turn burners
on or off by pressing the ON or OFF buttons on the hand-held re­mote control unit.
• In A UTO mode, the room tempera-
ture is controlled by the thermo­stat in the hand-held remote con­trol unit. To increase the room tem­perature, press the top arrow of the TEMP button. To lower room the temperature, press the bottom ar ­row to the TEMP b utton. At higher settings the heater will run more.
IMPORTANT:
The hand-held remote control unit must be near the heater. Do not keep the hand-held remote control unit too close the heater. The thermostat on the hand-held remote control unit will heat up too quickly and turn the heater off.
3. Use the ST A TUS button on the hand­held remote control unit to see the operation mode being used and the temperature setting selected. A red light will come on beside the opera­tion mode being used when the sta­tus button is pressed.
4. To turn the burners off when oper­ating in the MANUAL mode, press the OFF button. If operating in the auto mode, press the manual button, then press the OFF button The pilot will remain lit.
IMPORT ANT
: T o turn the pilot off, manually turn the con­trol knob on the heater to the OFF position or set remote selector switch to OFF position.
Control Knob in On PositionFlame Adjustment Knob
Shutting Off Burners Only (pilot stays lit)
You may shut off the burners and keep the pilot lit by doing one of the following:
• Turn control knob clockwise to the PILOT position.
• Use remote control manual OFF button.
• Set remote selector switch in the OFF position.
I
ON OFF REMOTE
Remote Selector Switch in Remote Position
Figure 28 - Setting the Remote Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation
16
H
L
O
P
I
L
O
F
T
F
O
O
N
104307
Page 17
OWNER’S MANUAL
OPERATING HEATER
Continued
Shows Temperature Setting
Allows Burners to be Turned On and Off with the Hand­Held Remote Unit.
The log heater will automati­cally cycle between pilot and the heat setting that has been selected.
Figure 29 - Thermostat Hand-Held Remote Control Unit Selections
INSPECTING
HI
TEMP
LO
MAN ON
AUTO OFF
STATUS
Increases Room Temperature
Decreases Room Temperature
Turns Burners On and Off
Shows Current Operation Mode
Pilot Burner
Thermocouple
BURNERS
Check pilot flame pattern and burner flame patterns often.
PILOT FLAME PATTERN
Figure 30 shows a correct pilot flame pat­tern. Figure 31 shows an incorrect pilot flame pattern. The incorrect pilot flame is not properly heating the thermocouple. When the thermocouple cools, the heater will shut down.
Pilot Burner
Figure 30 - Correct Pilot Flame Pattern
Thermocouple
Figure 31 - Incorrect Pilot Flame Pattern
If pilot flame pattern is incorrect, as shown in Figure 31
• turn heater off (see To Turn Off Gas to Appliance, page 16)
• see Troubleshooting, pages 18 through 20
MAIN BURNER
Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may be­come blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Either remove blockage or replace burner. Blocked burner flame holes will create soot.
CLEANING AND MAINTENANCE
WARNING: Turn off heater
and let cool before cleaning.
CAUTION: You must keep control areas, burner, and circu­lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali­fied service person. Heater may need more frequent cleaning due to excessive lint from carpeting, pet hair, etc.
ODS/PILOT AND BURNER
• Use a vacuum cleaner or small, soft bristled brush to clean.
LOGS
• If you remove logs for cleaning, refer to Installing Logs, pages 13 and 14, to prop­erly replace logs.
• Replace log(s) if broken or chipped (dime-sized or larger).
BURNER PRIMARY AIR HOLE
Air is drawn into the burner through the 8 holes in the brass fitting at the burner en­trance. There holes may become blocked with dust or lint. Periodically inspect these holes for any blockage and clean if needed. Blocked air holes will create soot.
MAIN BURNER
Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may be­come blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Either remove blockage or replace burner. Blocked burner flame holes will create soot.
104307
17
Page 18
CGD3924PR, CGB3924PR and CGB3930PR
UNVENTED PROPANE/LP GAS LOG HEATER
TROUBLESHOOTING
Note:
All troubleshooting items are listed in
order of operation.
OBSERVED PROBLEM
When ignitor button is pressed, there is no spark at ODS/pilot
When ignitor button is pressed, there is spark at ODS/pilot but no ignition
WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.
POSSIBLE CAUSE
1. Ignitor electrode not connected to igni­tor cable
2. Ignitor cable pinched or wet
3. Piezo ignitor nut is loose
4. Broken ignitor cable
5. Bad piezo ignitor
6. Ignitor electrode broken
7. Ignitor electrode positioned wrong
1. Gas supply turned off or manual shutoff valve closed
2. Control knob not in PILOT position
3. Control knob not pressed in while in PILOT position
4. Air in gas lines when installed
5. Depleted gas supply
6. ODS/pilot is clogged
7. Gas regulator setting is not correct
CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.
REMEDY
1. Reconnect ignitor cable
2. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry
3. Tighten nut holding piezo ignitor to base panel of log set. Nut is located behind base panel.
4. Replace ignitor cable
5. Replace piezo ignitor
6. Replace piezo ignitor
7. Replace piezo ignitor
1. Turn on gas supply or open manual shutoff valve
2. Turn control knob to PILOT position
3. Press in control knob while in PILOT position
4. Continue holding down control knob. Repeat igniting operation until air is re­moved
5. Contact local propane gas company
6. Clean ODS/pilot (see Cleaning and Maintenance, page 17) or replace ODS/ pilot assembly
7. Replace gas control
ODS/pilot lights but flame goes out when control knob is released
1. Control knob not fully pressed in
2. Control knob not pressed in long enough
3. Manual shutoff valve not fully open
4. Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This prob­lem could be caused by one or both of the following: A) Low gas pressure B) Dirty or partially clogged ODS/pilot
5. Thermocouple connection loose at con­trol valve
6. Thermocouple damaged
7. Control valve damaged
18
1. Press in control knob fully
2. After ODS/pilot lights, keep control knob pressed in 30 seconds
3. Fully open manual shut-off valve
4. A) Contact local propane gas company B) Clean ODS/pilot (see Cleaning and Maintenance, page 17) or replace ODS/ pilot assembly
5. Hand tighten until snug, then tighten 1/4 turn more
6. Replace thermocouple
7. Replace control valve
104307
Page 19
TROUBLESHOOTING
Continued
OWNER’S MANUAL
OBSERVED PROBLEM
Burner does light after ODS/pilot is lit
Delayed ignition burner
Burner backfiring during combustion
Slight smoke or odor during initial operation
POSSIBLE CAUSE
1. Burner orifice clogged
2. Inlet gas pressure is too low
3. Burner orifice diameter is too small
4. Thermopile leads disconnected or im­properly connected
5. Burners will not come on in remote position
1. Manifold pressure is too low
2. Burner orifice clogged
1. Burner orifice is clogged or damaged
2. Damaged burner
3. Gas regulator defective
1. Not enough air
2. Gas regulator defective
3. Residues from manufacturing processes and logs curing
REMEDY
1. Clean burner (see Cleaning and Mainte­nance, page 17) or replace burner orifice
2. Contact local propane gas company
3. Replace burner orifice
4. Reconnect leads (see Wiring Diagram, page 21)
5. Replace battery in transmitter and receiver
1. Contact local propane gas company
2. Clean burner (see Cleaning and Mainte- nance, page 17) or replace burner orifice
1. Clean burner (see Cleaning and Mainte- nance, page 17) or replace burner orifice
2. Replace damaged burner
3. Replace gas control
1. Check burner for dirt and debris. If found, clean burner (see Cleaning and Maintenance, page 17)
2. Replace gas control
3. Problem will stop after a few hours of operation
Moisture/condensation noticed on windows
Heater produces a whistling noise when burner is lit
White powder residue forming within burner box or on adjacent walls or furniture
Remote doesn't function
1. Not enough combustion/ventilation air
1. Turning control knob to HI position when burner is cold
2. Air in gas line
3. Air passageways on heater blocked
4. Dirty or partially clogged burner orifice
1. When heated, vapors from furniture pol­ish, wax, carpet cleaners, etc. turn into white powder residue.
1. Battery is not installed. Battery power is low
1. Refer to Air for Combustion and Venti- lation requirements (page 4)
1. Turn control knob to LO position and let warm up for a minute
2. Operate burner until air is removed from line. Have gas line checked by local pro­pane gas company
3. Observe minimum installation clear­ances (see pages 7 through 9)
4. Clean burner (see Cleaning and Mainte- nance, page 17) or replace burner orifice
1. Turn heater off when using furniture polish, wax, carpet cleaners or similar products.
1. Replace 9-volt batteries in receiver and remote control
Continued
104307
19
Page 20
CGD3924PR, CGB3924PR and CGB3930PR
UNVENTED PROPANE/LP GAS LOG HEATER
TROUBLESHOOTING
Continued
WARNING: If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
IMPORTANT:
supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.
Operating heater where impurities in air exist may create odors. Cleaning
OBSERVED PROBLEM
Heater produces a clicking/ticking noise just after burner is lit or shut off
Heater produces unwanted odors
Heater shuts off in use (ODS operates)
Gas odor even when control knob is in OFF position
POSSIBLE CAUSE
1. Metal expanding while heating or con­tracting while cooling
1. Heater burning vapors from paint, hair spray, glues, cleaners, chemicals, new carpet, etc. (See ment above)
2. Gas leak. See W arning statement at
top of page
1. Not enough fresh air is available
2. Low line pressure
3. ODS/pilot is partially clogged
1. Gas leak. See W arning statement at
top of page
2. Control valve defective
IMPORTANT
state-
REMEDY
1. This is common with most heaters. If noise is excessive, contact qualified ser­vice person
1. Open window and ventilate room. Stop using odor causing products while heater is running
2. Locate and correct all leaks (see Check- ing Gas Connections, page 11)
1. Open window and/or door for ventilation
2. Contact local natural gas company
3. Clean ODS/pilot (see Cleaning and Maintenance, page 17)
1. Locate and correct all leaks (see Check- ing Gas Connections, page 11)
2. Replace control valve
Gas odor during combustion
1. Foreign matter between control valve and burner
2. Gas leak. See W arning statement at
top of page
20
1. Take apart gas tubing and remove for­eign matter
2. Locate and correct all leaks (see Check- ing Gas Connections, page 11)
104307
Page 21
OWNER’S MANUAL
SPECIFICATIONS
CGD3924PR/CGB3924PR/CGB3930PR
Btu (Variable) 20,000/39,000 Type Gas Propane Only Ignition Piezo Manifold Pressure 8.0" W.C. Inlet Gas Pressure (in. of water)
Maximum 14"
Minimum* 11" Shipping Weight 30 lbs. * For the purpose of input adjustment
WIRING DIAGRAM
On Off
Remote
Thermopile
Receiver
White
Red
Red
White
TPTH TH
Gas Control
TPTH
TP
ACCESSORIES
Purchase these fireplace accessories from your local dealer. If they can not supply these accessories, either contact your near­est Parts Central (see page 26) or call DESA International’s Sales Department at 1-800­972-7879 for referral information. You can also write to the address listed on the back page of this manual.
MANUAL SHUTOFF VALVE - GA5010
Manual shutoff valve with 1/8" NPT tap. Fits 1/2" NPT pipe.
TECHNICAL SERVICE
You may have further questions about in­stallation, operation, or troubleshooting.
If so, contact DESA International’s Techni­cal Service Department at
1-800-DESA LOG (1-800-337-2564).
104307
SERVICE HINTS
When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• propane gas supply may be low
When Gas Quality Is Bad
• pilot will not stay lit
• burners will produce flames and soot
• heater will backfire when lit You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local natural gas supplier.
21
FIREPLACE HOOD BLACK - GA6050 BRASS - GA6052 ANITQUE BRASS - GA6053
Helps deflect heat away from mantel or wall above fireplace.
LAVA ROCK - GA6060 (Not Shown)
Order when additional rock is desired. (3 lb. bag)
Page 22
CGD3924PR, CGB3924PR and CGB3930PR
UNVENTED PROPANE/LP GAS LOG HEATER
ILLUSTRATED PARTS BREAKDOWN
CGD3924PR
11
1
4
3
5
9
13
6
2
10
7
12
8
20
13
14
I
H
L
O
O
F
F
N
O
P
I
T
L
O
16
17
18
16
20
REMOTE OFF ON
15
21
19
HI
TEMP
MAN
AUTO
ONLO
OFF
STATUS
22 23
24
I
H
L
O
O
F
F
N
O
P
T
I
L
O
25
16
22
104307
Page 23
OWNER’S MANUAL
PARTS LIST
CGD3924PR
This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 26 of this manual.
KEY NO. PART NUMBER DESCRIPTION QTY.
1 103008-01 Back Log (#1) 1 2 103009-01 Middle Log (#2) 1 3 103010-01 Front Log (#3) 1 4 103011-01 Crossover Log (#4) 1 5 103778-01 ODS Pilot (LP) 1 6 098249-01 ODS Nut 2 7 103342-02 Burner Outlet Tube 1 8 098264-02 Male Connector 1 9 102843-01 Burner Clip 1 10 099056-17 Burner Orifice Injector 1 11 102966-01 Upper Bracket 1 12 102772-01 Burner 1 13 099387-09 Pilot Tube 1 14 103781-02 Gas Control Valve 1 15 103345-01 Lower Bracket 1 16 M11084-38 Screw, #8 x .38 7 17 102775-06CK Painted Base Assembly 1 18 098271-07 Ignitor Cable 1 19 102445-01 Piezo Ignitor 1 20 103823-01 Remote Set (Incl. Transmitter) 1 21 104099-01 Heat Shield 1 22 098304-01 Screw 2 23 103784-02 Flame Adjustment Knob 1 24 103784-01 Off-Pilot-On Knob 1 25 M12461-26 Screw, Hex Slt Wsr 10-32 x .38 4
104307
PARTS AVAILABLE — NOT SHOWN
100563-01 Warning Plate 1 103877-01 Lighting Instructions Plate 1 100565-01 Warning Plate Fastener 1 100639-01 Caution Decal 1 101137-02 Hardware Kit 1 104310-02 Information Video 1 GA6060 Lava Rock 1
23
Page 24
CGD3924PR, CGB3924PR and CGB3930PR
UNVENTED PROPANE/LP GAS LOG HEATER
ILLUSTRATED PARTS BREAKDOWN
CGB3924PR CGB3930PR
5
1
3
2
4
6
9
13
7
10
26
12
20
11
8
16
13
14
I
H
L
O
O
F
F
N
O
P
I
T
L
O
16
25
15
16
17
18
HI
TEMP
MAN
AUTO
ONLO
OFF
STATUS
19
22 23
I
H
L
O
O
F
F
N
O
P
T
I
L
O
20
21
REMOTE OFF ON
24
24
104307
Page 25
OWNER’S MANUAL
PARTS LIST
CGB3924PR CGB3930PR
This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 26 of this manual.
KEY CGB3924PR CGB3930PR NO. PART NUMBER PART NUMBER DESCRIPTION QTY.
1 104897-01 104897-02 Middle Log (#1) 1 2 104898-01 104898-02 Back Log (#2) 1 3 104899-01 104899-02 Crossover Log (#3) 1 4 104896-01 104896-02 Front Log (#4) 1 5 104900-01 104900-02 Log Piece (#5) 1 6 103778-01 103778-01 ODS Pilot (LP) 1 7 098249-01 098249-01 ODS Nut 2 8 098264-02 098264-02 Male Connector 1 9 102843-01 102843-01 Burner Clip 1 10 099056-17 099056-17 Burner Orifice Injector 1 11 102966-01 102966-01 Upper Bracket 1 12 102772-01 102772-01 Burner 1 13 099387-09 099387-09 Pilot Tube 1 14 103781-02 103781-02 Gas Control Valve 1 15 103345-01 103345-01 Lower Bracket 1 16 M11084-38 M11084-38 Screw, #8 x .38 7 17 102775-06CK 102775-06CK Painted Base Assembly 1 18 098271-07 098271-07 Ignitor Cable 1 19 102445-01 102445-01 Piezo Ignitor 1 20 103823-01 103823-01 Remote Set (Incl. Transmitter) 1 21 104099-01 104099-01 Heat Shield 1 22 098304-01 098304-01 Screw 2 23 103784-02 103784-02 Flame Adjustment Knob 1 24 103784-01 103784-01 Off-Pilot-On Knob 1 25 M12461-26 M12461-26 Screw, Hex Slt Wsr 10-32 x .38 4 26 103342-02 103342-02 Burner Outlet Tube 1
104307
PARTS AVAILABLE — NOT SHOWN
100563-01 100563-01 Warning Plate 1 103877-01 103877-01 Lighting Instructions Plate 1 100565-01 100565-01 Warning Plate Fastener 1 100639-01 100639-01 Caution Decal 1 101137-02 101137-02 Hardware Kit 1 104310-02 104310-02 Information Video 1 GA6060 GA6060 Lava Rock 1
25
Page 26
CGD3924PR, CGB3924PR and CGB3930PR
UNVENTED PROPANE/LP GAS LOG HEATER
REPLACEMENT PARTS
Note:
Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this prod­uct. If they can’t supply original replace­ment part(s), call DESA International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564).
PARTS CENTRAL
Baltimore Electric
1348 Dixwell Avenue Hamden, CT 06514 1-800-397-7553 203-248-7553 Parts Department
Portable Heater Parts
342 N. County Rd. 400 East Valparaiso, IN 46383 All States 219-462-7441 1-800-362-6951
FBD
1349 Adams St. Bowling Green, KY 42103 502-846-1199 1-800-654-8534
Four Flags Power Products
1115 Stateline Road Niles, MI 49120 616-684-2697 1-800-268-4983 Parts Only
When calling DESA International, have ready
• your name
• your address
• model number of your heater
• how heater was malfunctioning
• type of gas used (propane or natural gas)
• purchase date Usually, we will ask you to return the defec-
tive part to the factory.
These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories. When calling a Parts Central, ask for the Parts Department.
Washer Equipment Co.
1715 Main Street Kansas City, MO 64108 KS, MO, AR 816-842-3911
East Coast Energy
Products 707 Broadway W. Long Branch, NJ 07764 732-870-8809 1-800-755-8809
PARTS NOT UNDER WARRANTY
Contact authorized dealers of this product. If they can’t supply original replacement part(s), either contact your nearest Parts Central (see below) or call DESA International’s Parts Department at 1-800-972-7879 for referral information.
When calling DESA International, have ready
• model number of your heater
• the replacement part number
Halco Enterprises
208 Carter Drive, Unit 21 West Chester, PA 19382 610-430-7717 1-800-368-0803
LA Porte’s Parts & Service
2444 N. 5th Street Hartsville, SC 29550 803-332-0191 Parts Department
Cans Unlimited, Inc.
Tarantin Tank Co.
P.O. Box 6129 Freehold, NJ 07728 908-780-9340 1-800-922-0724
Dayton Hardware
P.O. Box 275 North Dayton Station Dayton, OH 45404 All States 937-258-3721 OH 1-800-762-3426
P.O. Box 645 Taylor, SC 29687 All States 803-879-3009 1-800-845-5301
Heater and Fireplace Store
1922 N Route 9 Cape May Court, NJ 08210 609-624-0678 Parts Department
Master Parts Distribution
1184 Wilson Ave. NW Grand Rapids, MI 49504 616-791-8270 1-800-446-1446
26
104307
Page 27
OWNER’S MANUAL
NOTES
_______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________
104307
27
Page 28
WARRANTY INFORMATION
KEEP THIS WARRANTY
Model Serial No. Date Purchased
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
LIMITED WARRANTY
COMFORT GLOW VENT-FREE PROPANE GAS LOG HEATERS
DESA International warrants this product to be free from defects in materials and components for two (2) year from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEAR ON ALL COMPO­NENTS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSE­QUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state. For information about this warranty write: