Desa VN2000BTB, CFN2000BTB Owner's Operation And Installation Manual

BLUE FLAME
®
VENT -FREE NATURAL GAS HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
18,000 and 28,000 Btu/Hr Thermostatically-Controlled Models
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
— Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a qualified installer, service
agency, or the gas supplier.
This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
Save this manual for future reference.
CONTENTS
SECTION PAGE
Safety Information.........................................................................2
Product Identification .................................................................... 4
Local Codes ................................................................................... 4
Unpacking......................................................................................4
Product Features ............................................................................ 4
Air for Combustion and Ventilation..............................................5
Installing To Wall..........................................................................9
Connecting To Gas Supply............................................................14
Checking Gas Connections............................................................15
Operating Heater ...........................................................................17
Inspecting Burner ..........................................................................20
Cleaning And Maintenance ........................................................... 22
Troubleshooting.............................................................................22
Technical Service .......................................................................... 26
Specifications ................................................................................26
Service Hints .................................................................................26
Service Publications ......................................................................27
Replacement Parts ......................................................................... 27
Illustrated Parts List.......................................................................28-29
Accessories ....................................................................................30
Warranty Information .................................................................... Back Cover
SAFETY
INFORMATION
W ARNINGS
IMPORTANT: Read this Owner’s Manual carefully and completely
before trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.
DANGER
Carbon monoxide poisoning may lead to death!
Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning
resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, persons with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.
Natural Gas: Natural gas is odorless. An odor-making agent is added to natural gas. The odor helps you detect a natural gas leak. However, the odor added to natural gas can fade. Natural gas may be present even though no odor exists.
Make certain you read and understand all Warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.
2
101809
SAFETY
W ARNINGS
Continued
INFORMATION
WARNING: Any change to this heater or its controls can be dangerous.
1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
2. If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not use any phone in your building
• immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions
• if you cannot reach your gas supplier, call the fire department
3. This heater shall not be installed in a bedroom or bathroom.
4. Never install the heater
• in a recreational vehicle
• where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater
• as a fireplace insert
• in high traffic areas
• in windy or drafty areas
5. This heater needs fresh, outside air ventilation to run properly. This heater has an oxygen depletion sensor (ODS) pilot light safety system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 5 through 8.
6. Keep all air openings in front and bottom of heater clear and free of debris. This will insure enough air for proper combustion.
7. If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced.
8. Do not run heater
• where flammable liquids or vapors are used or stored
• under dusty conditions
9. Never place any objects on the heater.
10.Surface of heater becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shutdown. Allow surface to cool before touching.
11.Carefully supervise young children when they are in same room with heater.
12.Make sure grill guard is in place before running heater.
13.Do not use heater if any part has been under water. Immediately call a quali­fied service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.
14.Turn off and unplug heater and let cool before servicing. Only a qualified service person should service and repair heater.
15.Operating heater above elevations of 4,500 feet could cause pilot outage.
101809
3
PRODUCT
IDENTIFICATION
LOCAL CODES
Ignitor Button Control Knob
Grill Guard
Glass Panel
Front Panel
Figure 1 - Vent-Free Natural Gas Heater
(Models VN2800BTB/CFN2800BTB Shown)
Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of National Fuel Gas Code ANSI Z223.1, also known as NFPA 54*.
Heater Cabinet
UNPACKING
PRODUCT
FEATURES
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
1. Remove heater from carton.
2. Remove all protective packaging applied to heater for shipment.
3. Check heater for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater.
Safety Device
This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.
Piezo Ignition System
This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.
Thermostatic Heat Control
This heater has a thermostat sensing bulb and a control valve. This results in the greatest heater comfort. This can also result in lower gas bills.
4
101809
AIR FOR
W ARNING
COMBUSTION
AND
VENTILATION
This heater shall not be installed in a confined space unless provisions are provided for adequate combustion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.
Today’s homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.
While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.
PROVIDING ADEQUATE VENTILATION
The following is excerpts from National Fuel Gas Code. NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three following ventilation classifications:
1. Unusually Tight Construction; 2. Unconfined Space; 3. Confined Space. The information on pages 5 through 8 will help you classify your space and provide adequate ventilation.
Unusually Tight Construction
The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.
Unusually tight construction is defined as construction where: a. walls and ceilings exposed to the outside atmosphere have a continu-
ous water vapor retarder with a rating of one perm or less with open-
ings gasketed or sealed b. weather stripping has been added on openable windows and doors c. caulking or sealants are applied to areas such as joints around window
and door frames, between sole plates and floors, between wall-ceiling
joints, between wall panels, at penetrations for plumbing, electrical, and
gas lines, and at other openings.
If your home meets all of the three criteria above, you must provide addi­tional fresh air. See
If your home does not meet all of the three criteria above, proceed to page 6.
Ventilation Air From Outdoors
and
, page 8
and
.
Unconfined Space
The National Fuel Gas Code, ANSIZ223.1, 1992, Section 5.3 defines uncon- fined space as having a minimum air volume of 50 cubic feet (127 cubic cm) for each 1000 Btu/Hr input rating of all appliances in the space (cubic feet equals length x width x height of space). Include adjoining rooms only if there are doorless passageways or ventilation grills between the rooms.
Confined Space
The National Fuel Gas Code, ANSIZ223.1, 1992, Section 5.3 defines confined space as having an air volume of less than 50 cubic feet (127 cubic cm) for each 1000 Btu/Hr input rating of all appliances in the space (cubic feet equals length x width x height of space). Include adjoining rooms only if there are doorless passageways or ventilation grills between the rooms.
101809
Continued
5
AIR FOR
COMBUSTION
AND
VENTILATION
Continued
DETERMINING AIR FLOW FOR HEATER LOCATION
Determining if You Have a Confined or Unconfined Space
Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with
doorless passageways or ventilation grills between the rooms.
1. Determine the volume of the space (length x width x height). Length x Width x Height = ___________________ cu. ft. (volume of space)
Example:
If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.
2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.
____________ (volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support)
Example:
Btu/Hr the space can support)
3. Add the Btu/Hr of all fuel burning appliances in the space.
Example:
* Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.
4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
_________________ Btu/Hr (maximum the space can support) _________________ Btu/Hr (actual amount of Btu/Hr used)
Example:
The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:
A. Rework worksheet, adding the space of an adjoining room. If the extra space provides
an unconfined space, remove door to adjoining room or add ventilation grills between
rooms. See Ventilation Air From Inside Building, page 7. B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 8. C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.
Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) =
2560 cu. ft. (volume of space)
2560 cu. ft. (volume of space) ÷ 50 cu. ft. = 51.2 or 51,200 (maximum
Vent-free heater ___________________ Btu/Hr Gas water heater* ___________________ Btu/Hr Gas furnace ___________________ Btu/Hr Vented gas heater ___________________ Btu/Hr Gas fireplace logs ___________________ Btu/Hr Other gas appliances* + ___________________ Btu/Hr Total = ___________________ Btu/Hr
Gas water heater 40,000 Btu/Hr Vent-free heater + 18,000 Btu/Hr Total = 58,000 Btu/Hr
51,200 Btu/Hr (maximum the space can support) 58,000 Btu/Hr (actual amount of Btu/Hr used)
6
101809
AIR FOR
COMBUSTION
AND
VENTILATION
Continued
W ARNING
If the area in which the heater may be operated is smaller than that defined as an unconfined space, provide adequate combus­tion and ventilation air by one of the methods described in the
National Fuel Gas Code, ANSI Z223.1, 1992, Section 5.3.
VENTILATION AIR
Ventilation Air From Inside Building
This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.
W ARNING
Rework worksheet, adding the space of the adjoining unconfined space. appliances in both spaces.
The combined spaces must have enough fresh air to supply all
Ventilation
Grills
into Adjoining
Room,
Option 1
12"
Ventilation Grills
Into Adjoining Room,
Option 2
Or
Remove Door into Adjoining
Room,
Option 3
12"
101809
Figure 2 - Ventilation Air from Inside Building
Continued
7
AIR FOR
COMBUSTION
AND
VENTILATION
Continued
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.
IMPORTANT:
a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.
Do not provide openings for inlet or outlet air into attic if attic has
Outlet Air
Inlet Air
Outlet Air
Inlet Air
Figure 3 - Ventilation Air from Outdoors
Ventilated Attic
Ventilated
Crawl Space
To Attic
To
Crawl
Space
8
101809
INSTALLING TO
NOTICE
WALL
A qualified service person must install heater. Follow all local codes.
CHECK GAS TYPE
Use only natural gas. If your gas supply is not natural, do not install heater. Call dealer where you bought heater for proper type heater.
INSTALLATION ITEMS
Before installing heater, make sure you have the items listed below:
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• manual shutoff valve * * An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 30.
• ground joint union
• test gauge connection * (see Figure 13, page 15)
• sediment trap
• tee joint
• pipe wrench
LOCATING HEATER
This heater is designed to be mounted on a wall.
W ARNING
Maintain the minimum clearances shown in Figure 4 (page 10). If you can, provide greater clearances from floor, ceiling, and joining wall.
You can locate heater on floor, away from a wall. An optional floor mounting stand is needed. Purchase the floor mounting stand from your dealer. See Accesso- ries, page 30.
W ARNING
Never install the heater
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater
• as a fireplace insert
• in high traffic areas
• in windy or drafty areas
CAUTION
This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities in the air (such as tobacco smoke) exist, may discolor walls.
IMPORTANT:
stalling heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 5 through 8.
Vent-free heaters add moisture to the air. Although this is beneficial, in-
CAUTION
If you install the heater in a home garage
• heater pilot and burner must be at least 18 inches above floor
• locate heater where moving vehicle will not hit it
101809
Continued
9
INSTALLING TO
WALL
For convenience and efficiency, install heater
• where there is easy access for operation, inspection, and service
• in coldest part of room
Continued
An optional fan kit is available from your dealer. See Accessories, page 30. If planning to use fan, locate heater near an electrical outlet.
CEILING
36"
6" Minimum From Sides Of Heater
Left Side
FLOOR
Figure 4 - Mounting Clearances As Viewed From Front of Heater
Minimum
Right Side
3"
Minimum To Top Surface Of Carpeting, Tile Or Other Combustible Material
THERMOSTAT SENSING BULB
The thermostat sensing bulb has been placed inside the heater for protection during shipping.
Locating Thermostat Sensing Bulb
1. Remove front panel of heater (see Figure 7, page 11).
2. Locate thermostat sensing bulb just under burner assembly.
IMPORTANT:
Attaching Thermostat Sensing Bulb
1. Remove thermostat sensing bulb from holders inside heater. Route through slot opening in bottom of heater.
2. Place clamp on thermostat sensing bulb as shown in Figure 5. Clamp is provided in hardware package.
3. Snap clamp into upper mounting hole as shown in Figure 5. Mounting hole is located on lower left edge on back of heater. Make sure the thermostat sensing bulb is pointing up.
Attach thermostat sensing bulb to back of heater for proper operation.
Thermostat Sensing Bulb
Clamp
10
Figure 5 - Attaching Thermostat Sensing Bulb
101809
INSTALLING TO
WALL
Continued
INSTALLING HEATER TO WALL
Mounting Bracket
The mounting bracket is located on back panel of heater. It has been taped there for shipping. Remove mounting bracket from back panel.
Mounting Bracket
Figure 6 - Mounting Bracket
Removing Front Panel Of Heater
1. Remove two screws near bottom corners of front panel.
2. Lift straight up on grill guard until it stops. Grill guard will slide up about 1/4".
3. Pull bottom of front panel forward, then down.
4. Remove cardboard packing from grill and glass.
101809
Figure 7 - Removing Front Panel Of Heater
Methods For Attaching Mounting Bracket To Wall
Only use last hole on each end of mounting bracket to attach bracket to wall. These two holes are 16 inches apart from their centers. Attach mounting bracket to wall in one of two ways.
1. Attaching to wall stud
2. Attaching to wall anchor
Attaching to wall stud This method provides the strongest hold. Insert mounting
screws through mounting bracket and into wall studs.
Attaching to wall anchor This method allows you to attach mounting bracket to
hollow walls (wall areas between studs) or to solid walls (concrete or masonry). Decide which method better suits your needs. Either method will provide a secure
hold for the mounting bracket.
Continued
11
INSTALLING TO
WALL
Marking Screw Locations
1. Tape mounting bracket to wall where heater will be located. Make sure mount­ing bracket is level.
Continued
W ARNING
Maintain minimum clearances shown in Figure 8. If you can, provide greater clearances from floor and joining wall.
2. Mark screw locations on wall (see Figure 8).
Note:
Only mark last hole on each end of mounting bracket. Insert mounting
screws through these holes only.
3. Remove tape and mounting bracket from wall.
11"
Min.
Only Insert Mounting
Screws Through Last
Hole On Each End
Adjoining Wall
Floor
Model VN2800BTB and
CFN2800BTB
16"
18 3/4"
Min.
7 1/4"
Min.
Only Insert Mounting Screws Through Last
Hole On Each End
Adjoining Wall
Models VN2000BTB and
16"
Floor
CFN2000BTB
18 3/4"
Min.
Figure 8 - Mounting Bracket Clearances
Attaching Mounting Bracket To Wall
Note:
Wall anchors, mounting screws, and spacers are in hardware package. The
hardware package is provided with heater.
Attaching to wall stud method
For attaching mounting bracket to wall studs
1. Drill holes at marked locations using 9/64" drill bit.
2. Place mounting bracket onto wall. Line up last hole on each end of bracket with holes drilled in wall.
3. Insert mounting screws through bracket and into wall studs.
4. Tighten screws until mounting bracket is firmly fastened to wall studs.
Attaching to wall anchor method
For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry)
1. Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1" deep.
2. Fold wall anchor as shown in Figure 9.
12
3. Insert wall anchor (wings first) into hole. Tap anchor flush to wall.
Figure 9 - Folding Anchor
101809
INSTALLING TO
WALL
Continued
4. For thin walls (1/2" or less), insert red key into wall anchor. Push red key to “pop” open anchor wings. For thick walls (over 1/2" thick) or solid walls, do not pop open wings.
Figure 10 - Popping Open Anchor Wings For Thin Walls
5. Place mounting bracket onto wall. Line up last hole on each end of bracket with wall anchors.
6. Insert mounting screws through bracket and into wall anchors.
7. Tighten screws until mounting bracket is firmly fastened to wall.
Placing Heater On Mounting Bracket
1. Locate two horizontal slots on back panel of heater.
2. Place heater onto mounting bracket. Slide horizontal slots onto stand-out tabs on mounting bracket.
Stand-Out Tab
IMPORTANT
:
Do not hammer key!
Horizontal Slots
Mounting Bracket (attached to wall)
Figure 11 - Mounting Heater Onto Mounting Bracket
Installing Bottom Mounting Screws
1. Locate two bottom mounting holes. These holes are near bottom on back panel of heater (see Figure 12).
2. Mark screw locations on wall.
3. Remove heater from mounting bracket.
4. If installing bottom mounting screws into hollow or solid wall, install wall anchors. Follow steps 1 through 4 under Attaching To Wall Anchor Method, page 12. If installing bottom mounting screw into wall stud, drill holes at marked loca­tions using 9/64" drill bit.
5. Replace heater onto mounting bracket.
6. Place spacers between bottom mounting holes and wall anchor or drilled hole.
7. Hold spacer in place with one hand. With other hand, insert mounting screw through bottom mounting hole and spacer. Place tip of screw in opening of wall anchor or drilled hole.
8. Tighten both screws until heater is firmly secured to wall. Do not over tighten.
Note:
Do not replace front panel at this time. Replace front panel after making
gas connections and checking for leaks. (see pages 14-16)
101809
Figure 12 - Installing Bottom Mounting Screws
13
CONNECTING
TO GAS
SUPPLY
NOTICE
A qualified service person must connect heater to gas supply. Follow all local codes.
W ARNING
Never connect heater to private (non-utility) gas well. This gas is commonly known as wellhead gas.
IMPORTANT:
pressure must be no greater than 14 inches of water. If gas line pressure is higher, heater regulator damage could occur.
Check gas line pressure before connecting heater to gas line. Gas line
CAUTION
Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of large enough diameter to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.
Typical Pipe Diameters
VN2000BTB/CFN2000BTB 3/8" or greater VN2800BTB/CFN2800BTB 1/2" or greater
Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 13, page 15).
Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
Use pipe joint sealant that is resistant to natural gas.
Install sediment trap in supply line as shown in Figure 13, page 15. Locate sediment trap where it is within reach for cleaning. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.
14
CAUTION
101809
CONNECTING
TO GAS
SUPPLY
Continued
IMPORTANT:
and/or fittings.
1/2" NPT Pipe Nipple
Hold pressure regulator with wrench when connecting it to gas piping
Note:
Burner bracket
Pressure Regulator
not shown for clarity
CHECKING
GAS
CONNECTIONS
Ground Joint
Tee Joint
Test
Gauge
Connection *
Sediment
Trap
* An A.G.A. design certified manual shutoff valve with 1/8" NPT tap is an accept­able alternative to test gauge connection. Purchase the optional A.G.A. design certified manual shutoff valve from your dealer. See Accessories, page 30.
Reducer Bushing to 1/8" NPT
1/8" NPT Plug Tap
Tee Joint Pipe
Nipple Cap
Figure 13 - Gas Connection
Union
(4" W.C. to 10.5" W.C.
3" Minimum
Heater Cabinet
Manual Shutoff
Valve *
From Gas Meter
Pressure)
W ARNING
Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once.
PRESSURE TESTING GAS SUPPLY PIPING SYSTEM
Test Pressures In Excess Of 1/2 PSIG
1. Disconnect heater and its individual manual shutoff valve from gas supply
2. Cap off open end of gas pipe where manual shutoff valve was connected.
3. Pressurize supply piping system by either using compressed air or
101809
W ARNING
Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.
piping system. Pressures in excess of 1/2 PSIG will damage heater regulator.
opening main gas valve located on or near gas meter.
Continued
15
CHECKING
GAS
4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.
5. Correct all leaks at once.
CONNECTIONS
Continued
Test Pressures Equal To or Less Than 1/2 PSIG
1. Close manual shutoff valve (see Figure 14).
2. Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter.
3. Check all joints from gas meter to manual shutoff valve (see Figure 15). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.
4. Correct all leaks at once.
PRESSURE TESTING HEATER GAS CONNECTIONS
1. Open manual shutoff valve (see Figure 14).
2. Open main gas valve located on or near gas meter.
3. Make sure control knob of heater is in the OFF position.
4. Check all joints from manual shutoff valve to thermostat gas valve (see Figure
15). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light heater (see Operating Heater, pages 17 through 19). Check all other internal joints for leaks.
7. Turn off heater (see To Turn Off Gas to Appliance, page 19).
8. Replace front panel.
Manual Shutoff Valve
Gas Meter
ON
Open
POSITION
OFF
POSITION
Closed
Figure 14 - Manual Shutoff Valve
Thermostat Gas Valve
Manual Shutoff Valve
16
Figure 15 - Checking Gas Joints
101809
OPERATING
HEATER
FOR YOUR SAFETY READ BEFORE LIGHTING
W ARNING
If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand. When lighting
the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure
to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob. Never use
tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water. Immediately
call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above.
2. Make sure manual shutoff valve is fully open.
3. Turn control knob clockwise
Ignitor Button
IGNITOR
to the OFF position.
Clockwise
PILOT
OFF
HI
Control Knob
LO
101809
Figure 16 - Control Knob In The OFF Position
Continued
17
OPERA TING
HEA TER
Continued
4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information at the top of page 17. If you don’t smell gas, go to the next step.
5. Turn control knob counterclockwise
C-clockwise
to the PILOT position. Press
in control knob for five (5) seconds (see Figure 16).
Note:
You may be running this heater for the first time after hooking up
to gas supply. If so, the control knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.
• If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.
6. With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. The pilot can be seen through the glass panel. If needed, keep pressing ignitor button until pilot lights.
Note:
If pilot does not stay lit, refer to Troubleshooting, pages 22 through
25. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 19.
Ignitor Electrode
Thermocouple
Figure 17 - Pilot
Pilot Burner
7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
• If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.
Note:
If pilot goes out, repeat steps 3 through 7. This heater has a safety
interlock system. Wait one (1) minute before lighting pilot again.
8. Turn control knob counterclockwise main burner should light. Set control knob to any heat level between HI and LO.
Do not try to adjust heating levels by using the manual shutoff valve.
18
C-clockwise
to desired heating level. The
CAUTION
101809
TO TURN OFF GAS TO APPLIANCEOPERA TING
HEA TER
Continued
Shutting Off Heater
1. Turn control knob clockwise
to the OFF position.
Clockwise
2. Turn off all electric power to the appliance if service is to be performed.
Shutting Off Burner Only (pilot stays lit)
1. Turn control knob clockwise
to the PILOT position.
Clockwise
THERMOSTA T CONTROL OPERATION
The thermostatic control used on these models differs from standard thermo­stats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room temperature. The thermostat adjusts the amount of gas flow to the burner. This increases or decreases the burner flame height. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any heat level between HI and LO. Selecting the HI setting will cause the burner to remain fully on without modulating down in most cases.
Note:
The thermostat sensing bulb measures the temperature of air near the heater cabinet. This may not always agree with room temperature (depending on housing construction, installation location, room size, open air tempera­tures, etc.). Frequent use of your heater will let you determine your own comfort levels.
MANUAL LIGHTING PROCEDURE
1. Remove front panel (see Figure 7, page 11).
2. Follow steps 1 through 5 under Lighting Instructions, pages 17 and 18.
3. With control knob pressed in, strike match. Hold match to pilot until pilot
lights.
4. Keep control knob pressed in for 30 seconds after lighting pilot. After 30
seconds, release control knob.
5. Replace front panel.
101809
19
INSPECTING
Check pilot flame pattern and burner flame pattern often.
BURNER
PILOT FLAME PATTERN
Figure 18 shows a correct pilot flame pattern. Figure 19 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.
Thermocouple
Figure 18 - Correct Pilot Flame Pattern
Thermocouple
Pilot Burner
Pilot Burner
Figure 19 - Incorrect Pilot Flame Pattern
If pilot flame pattern is incorrect, as shown in Figure 19
• turn heater off (see To Turn Off Gas to Appliance, page 19).
• see Troubleshooting, pages 22 through 25.
20
101809
INSPECTING
BURNER
Continued
BURNER FLAME PATTERN
Figure 20 shows a correct burner flame pattern. Figure 21 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame. It also shows the flame higher than 1/2 the glass panel height.
W ARNING
If yellow tipping occurs, your heater could produce increased levels of carbon monoxide. If burner flame pattern shows yellow tipping, follow instructions at bottom of this page.
NOTICE
Do not mistake orange flames with yellow tipping. Dirt or other fine particles enter the heater and burn causing brief patches of orange flame.
CORRECT FLAME PATTERN
AT HIGH POSITION
Figure 20 - Correct Burner Flame Pattern
INCORRECT FLAME PATTERN
AT HIGH POSITION
Figure 21 - Incorrect Burner Flame Pattern
If burner flame pattern is incorrect, as shown in Figure 21
• turn heater off (see To Turn Off Gas to Appliance, page 19).
• see Troubleshooting, pages 22 through 25.
1/2 GLASS HEIGHT
Yellow Tipping
1/2 GLASS HEIGHT
101809
21
CLEANING
AND
MAINTENANCE
W ARNING
Turn off heater and let cool before cleaning.
CAUTION
You must keep control areas, burner, and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, etc.
ODS/PILOT AND BURNER
• Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean.
CABINET
Air Passageways
• Use a vacuum cleaner or pressurized air to clean.
Exterior
• Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.
TROUBLE-
SHOOTING
Note:
All troubleshooting
items are listed in order of
operation.
W ARNING
Turn off and unplug heater and let cool before servicing. Only a qualified service person should service and repair heater.
CAUTION
Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit.
OBSERVED PROBLEM
When ignitor button is pressed, there is no spark at ODS/pilot
POSSIBLE CAUSE
1. Ignitor electrode posi­tioned wrong
2. Ignitor electrode broken
3. Ignitor electrode not con­nected to ignitor cable
4. Ignitor cable pinched or wet
5. Piezo ignitor nut is loose
6. Broken ignitor cable
7. Bad piezo ignitor
REMEDY
1. Replace ignitor
2. Replace ignitor
3. Reconnect ignitor cable
4. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry
5. Tighten nut holding piezo ignitor to heater cabinet. Nut is located inside heater cabinet at top
6. Replace ignitor cable
7. Replace piezo ignitor
22
101809
TROUBLE-
SHOOTING
Continued
OBSERVED PROBLEM
When ignitor button is pressed, there is spark at ODS/pilot but no ignition
POSSIBLE CAUSE
1. Gas supply turned off or manual shutoff valve closed
2. Control knob not in PILOT position
3. Control knob not pressed in while in PILOT position
4. Air in gas lines when installed
5. ODS/pilot is clogged
6. Gas regulator setting is not correct
REMEDY
1. Turn on gas supply or open manual shutoff valve
2. Turn control knob to PILOT position
3. Press in control knob while in PILOT position
4. Continue holding down control knob. Repeat igniting operation until air is removed
5. Clean ODS/pilot (see
Cleaning and Mainte­nance, page 22) or
replace ODS/pilot assembly
6. Replace gas regulator
ODS/pilot lights but flame goes out when control knob is released
1. Control knob not fully pressed in
2. Control knob not pressed in long enough
3. Safety interlock system has been triggered
4. Manual shutoff valve not fully open
5. Thermocouple connec­tion loose at control valve
6. Pilot flame not touch­ing thermocouple, which allows thermo­couple to cool, causing pilot flame to go out. This problem could be caused by one or both of the following: A) Low gas pressure B) Dirty or partially clogged ODS/pilot
7. Thermocouple dam­aged
8. Control valve damaged
1. Press in control knob fully
2. After ODS/pilot lights, keep control knob pressed in 30 seconds
3. Wait one minute for safety interlock system to reset. Repeat ignition operation
4. Fully open manual shut-off valve
5. Hand tighten until snug, then tighten 1/4 turn more
6. A) Contact local natural gas company
B) Clean ODS/pilot (see Cleaning and Maintenance, page
22) or replace ODS/ pilot assembly
7. Replace thermocouple
8. Replace control valve
101809
Continued
23
TROUBLE-
SHOOTING
Continued
OBSERVED PROBLEM
Burner does not light after ODS/pilot is lit
POSSIBLE CAUSE
1. Burner orifice is clogged
2. Burner orifice diameter is too small
3. Inlet gas pressure is too low
REMEDY
1. Clean burner (see
Cleaning and Mainte­nance, page 22) or
replace burner orifice
2. Replace burner orifice
3. Contact local natural gas company
Delayed ignition of burner
Burner backfiring during combustion
Yellow flame during burner combustion
Slight smoke or odor during initial opera­tion
1. Manifold pressure is too low
2. Burner orifice is clogged
1. Burner orifice is clogged or damaged
2. Burner damaged
3. Gas regulator defective
1. Not enough air
2. Gas regulator defective
1. Residues from manu­facturing processes
1. Contact local natural gas company
2. Clean burner (see
Cleaning and Mainte­nance, page 22) or
replace burner orifice
1. Clean burner (see
Cleaning and Mainte­nance, page 22) or
replace burner orifice
2. Replace burner
3. Replace gas regulator
1. Check burner for dirt and debris. If found, clean burner (see
Cleaning and Mainte­nance, page 22)
2. Replace gas regulator
1. Problem will stop after a few hours of operation
Heater produces a whistling noise when burner is lit
24
1. Turning control knob to HI position when burner is cold
2. Air in gas line
3. Air passageways on heater blocked
4. Dirty or partially clogged burner orifice
1. Turn control knob to LO position and let warm up for a minute
2. Operate burner until air is removed from line. Have gas line checked by local natural gas company
3. Observe minimum installation clearances (see Figure 4, page 10)
4. Clean burner (see
Cleaning and Mainte­nance, page 22) or
replace burner orifice
101809
TROUBLE-
SHOOTING
Continued
W ARNING
If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
IMPORTANT:
supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.
OBSERVED PROBLEM
Heater produces a clicking/ticking noise just after burner is lit or shut off
Heater produces unwanted odors
Heater shuts off in use (ODS operates)
Operating heater where impurities in air exist may create odors. Cleaning
POSSIBLE CAUSE
1. Metal expanding while heating or contracting while cooling
1. Heater burning vapors from paint, hair spray, glues, etc. (see
TANT
statement above).
2. Gas leak. See Warn-
ing statement at top of page.
1. Not enough fresh air is available
2. Low line pressure
3. ODS/pilot is partially clogged.
IMPOR-
REMEDY
1. This is common with most heaters. If noise is excessive, contact qualified service person
1. Ventilate room. Stop using odor causing products while heater is running
2. Locate and correct all leaks (see Checking Gas Connections, page 15)
1. Open window and/or door for ventilation
2. Contact local natural gas company
3. Clean ODS/pilot (see
Cleaning and Mainte­nance, page 22)
Gas odor even when control knob is in OFF position
Gas odor during combustion
Moisture/condensa­tion noticed on windows
101809
1. Gas leak. See Warn­ing statement at top of page.
2. Control valve defective
1. Foreign matter be­tween control valve and burner
2. Gas leak. See Warn-
ing statement at top of page.
1. Not enough combus­tion/ventilation air
1. Locate and correct all leaks (see Checking Gas Connections, page 15)
2. Replace control valve
1. Take apart gas tubing and remove foreign matter
2. Locate and correct all leaks (see Checking Gas Connections, page 15)
1. Refer to Air for Com-
bustion and Ventilation
requirements (page 5)
25
TECHNICAL
SERVICE
You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323-5190.
SPECIFICA TIONS
SERVICE
HINTS
VN2000BTB VN2800BTB CFN2000BTB CFN2800BTB
Btu (Variable) 9,000/18,000 14,000/28,000 Type Gas Natural Only Natural Only Ignition Piezo Piezo Pressure Regulator Setting 3" W.C. 3" W.C. Inlet Gas Pressure (in. of water)
Maximum 7" 7" Minimum 5" 5"
Dimensions, Inches (H x W x D)
Heater Carton 25.8 x 21.3 x 10.1 25.8 x 28.7 x 10.1
Weight (pounds)
Heater 22 30 Shipping 27 35
When gas pressure is too low
• pilot will not stay lit
• burner will have delayed ignition
• heater will not produce specified heat
(Includes knobs & grill)
23.5 x 18.5 x 8.0 23.5 x 25.9 x 8.0
When gas quality is bad
• pilot will not stay lit
• burner will produce flames and soot
• heater will backfire when lit
You may feel your gas pressure is too low or gas quality is bad. If so, contact your local natural gas supplier.
26
101809
SERVICE
PUBLICATIONS
REPLACEMENT
PARTS
You can purchase service manual from the address listed on the back page of this manual. Send a check for $5.00 payable to DESA International.
Note:
Use only original replacement parts. This will protect your warranty cover-
age for parts replaced under warranty.
Parts Under Warranty
Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Technical Service Department at 1-800-323-5190.
When calling DESA International, have ready
• your name
• your address
• model number of your heater
• how heater was malfunctioning
• type of gas used (propane or natural gas)
• purchase date
Usually, we will ask you to return the defective part to the factory.
Parts Not Under Warranty
Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Parts Department at 1-800-972-7879 for referral information.
When calling DESA International, have ready
• model number of your heater
• the replacement part number
101809
27
1
2
3
4
5
6
7
8
9
10
10
11
12
13
14
15
16
17
19
20
21
22
23
24
25
26
27
28
30
31
32
18
31
29
30
12-1
12-2
VN2000BTB
CFN2000BTB
VN2800BTB
CFN2800BTB
(Parts list on page 33)
12 ODS/Pilot Assembly
28
101809
P ARTS LIST
KEY PART NUMBER FOR NO. VN2000BTB CFN2000BTB VN2800BTB CFN2800BTB DESCRIPTION QTY.
1 098304-01 098304-01 098304-01 098304-01 Screw, #10 x 3/8" 2 2 098742-13 098742-17 098742-14 098742-18 Front Panel 1 3 098197-03 098197-03 098197-04 098197-04 Grill Guard 1 4 101108-01 101108-01 101108-01 101108-01 Clip, Grill Guard 2 5 098533-01AA 098533-01AA 098533-02AA 098533-02AA Bottom Glass Retainer 1 6 098260-01 098260-01 098260-02 098260-02 Glass Panel 1 7 098532-01AA 098532-01AA 098532-02AA 098532-02AA Top Glass Retainer 1 8 M11084-26 M11084-26 M11084-26 M11084-26 Screw, #10 x 3/8" 4 9 098352-01BR 098352-01BR 098352-02BR 098352-02BR Deflector Unit 1 10 098271-03 098271-03 098271-03 098271-03 Ignitor Cable 1 11 098249-01 098249-01 098249-01 098249-01 Nut, M5 2 12 099440-05 099440-05 099440-05 099440-05 ODS/Pilot Assembly 1 12-1 098514-01 098514-01 098514-01 098514-01 Thermocouple 1 12-2 098515-01 098515-01 098515-01 098515-01 Ignitor Electrode 1 13 099120-02 099120-02 099126-02 099126-02 Burner 1 14 099387-03 099387-03 099387-03 099387-03 3/16" Pilot Tubing 1 15 098251-02 098251-02 098251-04 098251-04 Injector 1 16 098250-01 098250-01 098250-01 098250-01 Injector Holder 1 17 098867-04 098867-04 098867-04 098867-04 Pressure Regulator 1 18 099553-01 099553-01 099553-01 099553-01 Pilot Shield 1 19 098518-01 098518-01 098518-01 098518-01 3/8" Outlet (Burner) Tubing 1 20 098297-03 098297-03 098297-03 098297-03 3/8" Inlet Tubing 1 21 098264-02 098264-02 098264-02 098264-02 3/8" NPT Male Connector 1 22 098276-01 098276-01 098276-01 098276-01 1/8" NPT Plug 1 23 098277-01 098277-01 098277-01 098277-01 3/8" to 1/8" NPT Bushing 1 24 098265-01 098265-01 098265-01 098265-01 3/8" NPT Male Elbow 1 25 098275-01 098275-01 098275-01 098275-01 3/8" NPT Plug 1 26 098522-03 098522-03 098522-04 098522-04 Thermostat Gas Valve 1 27 098530-01 098530-01 098531-01 098531-01 Cabinet 1 28 102445-01 102445-01 102445-01 102445-01 Piezo Ignitor 1 29 M11084-26 M11084-26 M11084-26 M11084-26 Screw, #10 x 3/8" 2 30 M11084-38 M11084-38 M11084-38 M11084-38 Screw, #8 x 3/8" 2 31 099066-01 099066-01 099066-01 099066-01 Mounting Bracket 1
This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 27 of this manual.
098305-01 098305-01 098305-01 098305-01 Control Position Label 1 100642-01 100642-01 100642-01 100642-01 Hardware Assembly 1
101809
PARTS AVAILABLE — NOT SHOWN
29
ACCESSORIES
Purchase these heater accessories from your local dealer. If they can not supply these accessories, call DESA International’s Parts Department at 1-800-972-7879 for referral information. You can also write to the address listed on the back page of this manual.
FAN KITS - GA3100A, and GA3200TA
For all models. Provides better heat distribu­tion. Makes heater more efficient. Complete
installation and operating instructions included.
Manually controlled - GA3100A. Includes ON/OFF switch.
Thermostatically controlled - GA32000TA. Includes three settings: ON/OFF/AUTO.
FLOOR MOUNTING STAND Model VN2000BTB - GA4000B Model VN2800BTB - GA4010B
For locating heater on the floor, away from a wall. Complete installation instructions included.
MANUAL SHUTOFF VALVE - GA5010
For all models. Manual shutoff valve with 1/8" NPT tap.
30
101809
NOTES
_________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________
101809
_________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________
31
WARRANTY INFORMATION
KEEP THIS WARRANTY
Model Serial No. Date Purchased
Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our
standard written warranty. We make no other warranty, expressed or implied.
LIMITED WARRANTY
VENT-FREE RESIDENTIAL GAS HEATERS
DESA International warrants this product to be free from defects in materials and components for three (3) years and five (5) years on stainless steel burners from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO THREE (3) YEARS ON ALL COMPONENTS AND FIVE (5) YEARS ON STAINLESS STEEL BURNERS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAM­AGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state. For information about this warranty write:
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004
101809-01 REV. C 4/96