Dema 693T Installation Manual

Page 1

ITEM DESCRIPTION QTY.

A. B. C. D. E. F. G. H.
2. INSTALLATION A. Mounting and Water Supply:
Locate mounting holes on a permanent vertical wall. Drill all holes into the d rywall u sing a ¼” diameter bit for u se with the included #10 screw and anchor set. (If mounting unit to wood and you do not plan to use the included anchors, drill 1/8” diameter holes.) Insert the anchors into drilled holes and hammer them into the wall until they are flush with face of wall. Assemble the #10 screws with a phillip screwdriver into the anchors for the keyhole slots so the screw heads are sticking out of the wall approximately ½”. Mount the unit by inserting the screw heads through the keyhole slots and tightening the screws. Secure the unit by inserting screws into the lower 2 holes.
The water inlet is equipped with a female garden hose fitting. The fitting may be removed to permit direct connection to 3/8” NPT pipe. Note: Apply pipe dope, hand tighten, and then turn 1-1/2 times with a wrench. DO NOT OVER
TIGHTEN.
WARNING: Do not the plastic to crack. Use non-welding liquid sealant instead.
B. Outlet Connection:
Connect the discharge hose to the garden hose fittin g. NOTE: Be sure to clamp garden hose onto wall approximately 1 ft. below the unit, (Clamps, screws, & anchors are not supplied.) Attach shut-off valve to the discharge end of the hose. See Table 1 for hose limitations.
C. Chemical Supply:
WARNING: USE CARE WHEN HANDLING HAZARDOUS CHEMICALS.
Place the chemical container in a convenient location not more than six feet below the Foam Station as greater lifts will reduce injection capabilities. The top of the container should not be above the Foam Station. Cut the vinyl tube to any convenient length that will allow the tubing to reach the bottom of the container. Drop the tubing end with the strainer into the chemical container. Push the other tubing end over the metering knob barb. Note: Remove ball valve knob
and Foam Station cover for chemical supply installation.
:
DEMA® MODEL 693T FOAM STATION II
INSTALLATION INSTRUCTION
:
Foam Station Assembly 1 ¼” ID Tubing & Foot Strainer 1 3/8” ID Tubing & Foot Strainer 1 Ceramic Weight (For ¼” ID Tubing) 1 Ceramic Weight (For 3/8” ID Tubing) 1 Metering Tip Kit 1 #10 Screw & Anchor Kit Set (Total: 4 Screws & 4 Anchors) 1 Label Card 1
use Teflon tape to seal internal plastic threads as the extra thickness of the tape may cause
I-747 Page 1 of 8 Rev. D-31918 12/22/05
Page 2
DEMA® MODEL 693T FOAM STATION II
3. CHEMICAL ADJUSTMENT
The chemical feed rate is controlled by metering tips screwed into the barb on the side of the Foam Station. The feed rates can be changed using different metering tips. To select the proper metering tip size for the desired dilution ratio, refer to Table 2 (Foamer) and Table 3 (P203 Injector).
1 cps (centipoise) is equal to the viscosity of water 75 cps is approximately equal to the viscosity of 10 weight motor oil 200 cps is approximately equal to the viscosity of most dishwashing detergents
Injection rate can be doubled with no tip by using ½” ID inlet tubing. Use a short piece of 3/8 in. ID tubing on proportioner and foot valve barbs for a bushing.
Metering Tip Color
Oz/Gal Ratio Oz/Gal Ratio Oz/Gal Ratio Oz/Gal Ratio
Clear 0.84 152-1 0.65 197-1 0.45 284-1 0.30 427-1 Purple 1.35 95-1 1.10 116-1 0.90 142-1 0.60 213-1 Yellow 2.40 53-1 2.00 64-1 1.50 85-1 1.10 116-1 Green 4.20 30-1 3.40 38-1 2.65 48-1 2.10 61-1 Pink 5.25 24-1 4.50 28-1 3.45 37-1 2.60 49-1 Turquoise 9.40 14-1 7.25 18-1 5.45 23-1 3.70 35-1 Black 11.75 11-1 8.80 15-1 6.35 20-1 4.20 30-1 Gray 14.50 9-1 10.80 12-1 7.75 17-1 4.75 27-1 Red 18.00 7-1 13.20 10-1 8.30 15-1 5.00 26-1 Blue 20.60 6-1 14.70 9-1 8.65 14.8-1 5.20 25-1 Brown 24.10 5-1 16.15 8-1 9.30 14-1 5.50 23-1 White 27.50 4.7-1 17.80 7-1 9.70 13-1 5.70 22-1 Orange 30.00 4.3-1 18.50 6.9-1 10.10 12.7-1 5.85 21.9-1 Light Blue* 32.00 4-1 18.90 6.8-1 10.20 12.5-1 6.00 21-1 Tan* 32.50 3.9-1 19.25 6.6-1 10.40 12.3-1 6.25 20.5-1 None 34.25 3.7-1 20.45 6-1 10.60 12-1 6.50 20-1
INSTALLATION INSTRUCTION
:
TABLE 1: Outlet Garden Hose Connection
GARDEN HOSE SIZE AND
LENGTH
25’ OF ¾” ID 40 PSI 40 PSI 50’ OF ¾” ID 50 PSI 40 PSI 25’ OF ½” ID 60 PSI 40 PSI

TABLE 2: Foamer Injection Rate

Injection Rate for Viscosities Shown

1 cps 75 cps 200 cps 500 cps
MIN. PRESSURES
WATER AIR
All induction rates are based on 40 psi water pressure and 40 psi air pressure.
*The tips are not included in the standard tip pack.
I-747 Page 2 of 8 Rev. D-31918 12/22/05
Page 3
DEMA® MODEL 693T FOAM STATION II
INSTALLATION INSTRUCTION

Table 3: P203CAM Injector Injection Rate

Metering
Tip Color
Oz/Gal Ratio Oz/Gal Ratio Oz/Gal Ratio
Tan 0.40 320-1 0.25 512-1 0.20 640-1 Orange 0.50 256-1 0.35 366-1 0.25 512-1 Turquoise 0.75 171-1 0.45 284-1 0.35 366-1 Pink 0.95 135-1 0.65 197-1 0.45 284-1 Light Blue* 1.30 98-1 0.80 160-1 0.55 233-1 Brown 1.50 85-1 0.90 142-1 0.60 213-1 Red 1.90 67-1 1.00 128-1 0.70 183-1 White 2.25 57-1 1.30 98-1 0.80 160-1 Green 2.64 49-1 1.50 85-1 0.90 142-1 Blue 3.20 40-1 1.75 73-1 1.00 128-1 Yellow 4.85 26-1 2.25 57-1 1.10 116-1 Black 6.50 20-1 2.40 53-1 1.15 111-1 Purple 9.20 14-1 2.70 47-1 1.20 107-1 Gray 10.40 12-1 2.85 45-1 1.25 102-1 No Tip 12.80 10-1 3.50 37-1 1.55 83-1
1 cps 75 cps 200 cps
Injection Rate for Viscosities Shown
All injection rates are based on 40 PSI inlet water pressure and a water flow rate of 2.5 GPM.
4. OPERATION:
The 693T Foam Station permits the operator to select a chemical to foam (left hand lever), or a chemical to spray (right hand lever) or a clear water rinse (middle lever) by opening and closing the appropriate valve with its lever. ONLY ONE VALVE SHOULD BE OPEN AT ANY TIME. If two valves are opened simultaneously, the injector will not draw chemical.
NOTE: When using the spray wand, make sure that the shut-off valve at the end of the hose is in the fully open position in order to draw chemical product.
To Foam First: Open the left hand lever all the way. Water rushing through the foamer will draw up soap and send soapy water
through the hose.
Next: Pull out on the air regulator knob above the air gage. Set the air regulator to 40psi. Open the air valve on the left side of the 693T. Adjust the air regulator upwards gradually until you obtain the thickness of foam you desire. Push the air regulator knob back in to lock the setting in place. This operation must be repeated in the same order each time the 693T is shut down and restarted (water first then gradually build up air pressure).
* Metering tip color was formerly clear.
:
TABLE 4: Water Flow & Air Flow Setting.
WATER FLOW (GPM) AIR FLOW (SCFM)
PRESSURE (PSI)
40 50 60 80
1.4 1.6 1.7 2.1
3.5 4.2 4.8 6.1
I-747 Page 3 of 8 Rev. D-31918 12/22/05
Page 4
DEMA® MODEL 693T FOAM STATION II
INSTALLATION INSTRUCTION
5. SERVICING: CAUTION: TURN OFF WATER SUPPLY BEFORE SERVICING. WHEN SERVICING UNIT, BE SURE THAT REPLACEMENT PARTS HAVE BEEN INSTALLED ACCORDING TO DRAWING. BE CERTAIN CHECK VALVE PARTS ARE IN PLACE.
PROBLEM SEE SITUATION: Unit will not draw or stops drawing chemical 1, 2, 3, 5, 6 , 10, 11, 12, 13, 15, 16, 17 Poor foam quality 1, 2, 3, 5, 6, 10, 11, 12, 13, 15, 16 Foam surges 1, 2, 3, 4, 5, 6, 8, 9, 10, 11, 12, 13, 15, 16 Foam output is too wet 1, 3, 4, 5, 6, 7, 8, 9, 10, 11, 13, 16 Foam output is too dry 2 Water is flowing into chemical container 12 Foam does not clean adequately 4, 8, 11, 14
POSSIBLE SITUATIONS
Situation Cause Solution
1
2 3 4 5 6 7 8
9
10 11 12 13 14
15
16
17
Chemical tube not immersed in chemical or chemical depleted. Air pressure is too high for water. Adjust air regulator down. Water pressure is too low. At least 30 psi is required. Increase if possible, or decrease air pressure. Chemical to water ratio is too low. Change metering tip to one that is larger. Foam hose is kinked. Straighten hose. Foam hose is too long or wrong size. See Table 1. Air supply is inadequate. Increase air pressure by regulating up. Detergent is wrong. Use a more effective detergent, and be sure that product is
Using an oiler on the airline may deteriorate the quality of the foam. Holes or cuts are in chemical inlet tube. Replace the tube. Strainer and/or metering tip are blocked. Remove, clean or replace. Solution check valve is not working. Remove, clean or replace. Air regulator is not working. Remove, clean or replace. Soil has hardened on surface. Reapplication may be necessary. Be sure to rinse foam off before it
Rust or build-up is clogging the foamer aspirator. Water scale or chemical build-up may have formed in the water jets.
More than one valve is open. Close the rinse valve and the injector valve that is not in use.
Immerse tube in chemical or replace.
recommended for foaming. Use only clean, dry air.
dries. Disconnect water from unit and remove injector from unit. Visually inspect. Remove blockage. Place the chemical tube in descaling acid and completely open the shut­off valve. Let unit run until the chemical tube is filled with acid, then close shut-off valve and water supply. Elevate the chemical tubing and outlet hose until acid has had enough time to descale. Repeat if necessary. For severe cases, disassemble unit and soak foamer body in descaling acid.
I-747 Page 4 of 8 Rev. D-31918 12/22/05
Page 5
DEMA® MODEL 693T FOAM STATION II
INSTALLATION INSTRUCTION

Return Policy

No merchandise may be returned for credit without DEMA Engineering Company’s written permission. Return Merchandise Authorization (RMA) number required in advance of return.

Warranty

DEMA products are warranted against defective material and workmanship under normal use and service for one year from the date of manufacture. This limited warranty does not apply to any products which have a normal life shorter than one year or failure and damage caused by chemicals, corrosion, improper voltage supply, physical abuse or misapplication. Rubber and synthetic rubber parts such as “O”-rings, diaphragms, squeeze tubing and gaskets are considered expendable and are not covered under warranty. This warranty is extended only to the original buyer of DEMA products. If products are altered or repaired without prior approval of DEMA, this warranty will be void.
Defective units or parts should be returned to the factory with transportation prepaid. If inspection shows them to be defective, they will be repaired or replaced without charge. F.O.B. factory DEMA assumes no liability for damages. Return merchandise authorization number to return units for repair or replacement must be granted in advance of return.
I-747 Page 5 of 8 Rev. D-31918 12/22/05
Page 6
DEMA® MODEL 693T FOAM STATION II
INSTALLATION INSTRUCTION
15
20
16
21
17
1
2
14
3
1918
FOAMER ASSEMBLY (SHOWN EXPLODED ON PAGE 8)
4
6
7
8
9
6
8
8
(SHOWN EXPLODED
11
5
6
P203CTC
ON PAGE 7)
10
8
NO. PART NO. DESCRIPTION
1 100-38 Strainer Washer 2 65-10 Swivel Coupling 3 65-14 Hose Fitting – Medium Long 4 69-8-2 Top Manifold 5 66-153 Pipe Plug & O-Ring Assy. 6 99-8-2 Valve 7 69-2 Adapter 8 30-5-14 O-Ring (EP)
9 58-83-1 Pipe Adapter (3/8”) 10 69-9-1 Adapter 11 69-4 Bottom Manifold 12 65-18-1 Outlet Fitting 13 93-15-2 Pressure Gauge 14 25-137-12 ¼” NPT Nipple X 1 ½ Lg.
13
12
ACCESSORY
22
23
NO. PART NO. DESCRIPTION
15 16-11 ¼” NPT Ball Valve 16 24-11L Foot Strainer (For 3/8” ID Tubing) 17 24-11MP Foot Strainer (For 1/4” ID Tubing) 18 61-107 Ceramic Weight (3/8” ID Tubing) 19 61-107-2 Ceramic Weight (1/4” ID Tubing) 20 100-12 Vinyl Tubing (1/4” ID X 8’ Lg.) 21 100-12L Vinyl Tubing (3/8” ID X 8’ Lg.)
ACCESSORIES
NO. PART NO. DESCRIPTION
22 93-18 Plastic Foam Wand 23 93-14 3/4” ID X 25’ Lg. Outlet Hose
I-747 Page 6 of 8 Rev. D-31918 12/22/05
Page 7
DEMA® MODEL 693T FOAM STATION II
INSTALLATION INSTRUCTION
BREAKDOWN OF P203CTC INJECTOR
1
10
2
4
5
3
6
7
8
9
NO. PART NO. DESCRIPTION
1 24-67 Screw (4 Req’d) 2 100-15- Metering Tip (Specify Color) 3 24-62-SP Metering Knob Kit 4 24-25S O-Ring (Silicone) 5 24-24P Check Valve Ball 6 24-23-2 Check Valve Spring – Hasteloy 7 24-37-7 Check Valve Core 8 25-29S O-Ring (Silicon) 9 24-68 Injector Body
ACCESSORIES
NO. PART NO. DESCRIPTION
10 100-15K Metering Tip Kit
I-747 Page 7 of 8 Rev. D-31918 12/22/05
Page 8
DEMA® MODEL 693T FOAM STATION II
INSTALLATION INSTRUCTION
26
16
25
15
14
22
13
21
1
2
3
5
4
6
9
12
7
11
10
17
8
19
24
NO. PART NO. DESCRIPTION
1 29-18-4 7/16 Internal Snap Ring 2 29-17-2 Washer (S.S.) – Air Nozzle 3 29-7 O-Ring (Viton) 4 29-5P Ball 11/32” Dia. (Teflon) 5 29-16 Nozzle 6 29-11 Diffuser 7 29-15-2 Pin 8 69-3 Adapter
9 29-12 Check Valve Repair Kit 10 25-29V Metering Knob O-Ring (Viton) 11 23-34-3 Check Valve Core 12 23-9-2 Check Valve Spring – Hasteloy 13 23-10 Ball (9/32” Dia.) – (S.S.) 14 23-11V Check Valve O-Ring (Viton) 15 23-32T Metering Knob
23
20
NO. PART NO. DESCRIPTION
18
16 61-9- Metering Tip (Specify Color) 17 30-5V-14 O-Ring (Viton) 18 29-14 Air Nozzle 19 93-6-2 Air Check Valve Spring - Hasteloy 20 26-49P Ball 3/16” (Teflon) 21 90-35V Air Check Valve O-Ring (Viton) 22 29-17-3 Washer (S.S.) – Foamer Inlet 23 29-18-2 5/16” Internal Snap Ring 24 93-1 Pressure Regulator 25 29-10 Hi Lo Screw (4 Req’d)
ACCESSORIES
NO. PART NO. DESCRIPTION
26 61-9K Metering Tip Kit
I-747 Page 8 of 8 Rev. D-31918 12/22/05