DEMA 6300, 6300-3, 6300-2, 6300-4, 6300-5 Instruction Sheet

...
Page 1
DEMA RAPID FIRE MODELS
6300, 6300-2, 6300-3, 6300-4 6300-5, 6310, 6300H 6300E, 6300EH, &6310E
INSTRUCTION SHEET
I-1002 Pg. 1 of 12 Rev. G-40295 11/25/14
Page 2
DEMA RAPID FIRE MODELS
6300, 6300-2, 6300-3, 6300-4 6300-5, 6310, 6300H 6300E, 6300EH, &6310E
INSTRUCTION SHEET
The RAPID FIRE is a spray system designed with a single knob to control OFF, RINSE and up to two chemicals using a single chemically resistant plastic injector. There is full water flow whenever the valve is open with the option of using a 2.1 or a 3.3 injector. A 2.7 gallon per minute injector is standard. RAPID FIRE dispensers can be used in any application where a chemical product must be sprayed or foamed without the use of compressed air or a high pressure pump. City water pressure and optional spray gun and foam wand attachments create the correct amount of pressure and foam for cleaning in food service applications such as supermarket meat rooms, deli areas, and seafood departments.
The RAPID FIRE offers the following advantages over a traditional spray system:
No manifold Polypropylene injector for chemical resistance
No ball valves Large knob for easy turning. 6 GPM Rinse Flow
Stainless Steel cover with foam wand storage offers neat appearance
NOTE: ALL INSTALLATIONS MUST CONFORM TO LOCAL PLUMBING CODES AND US E THE APPROVED
WARNING: WATER SUPPLY PRESSURE MUST NOT EXCEED 125 PSI AND WATER TEMPERATURE MUST
CAUTION: TURN OFF WATER SUPPLY BEFORE SERVICING. WHEN SERVICING UNIT BE SURE THAT
1. PARTS CHECKLIST: (By RAPID FIRE model number.)
BACKFLOW PREVENTORS.
NOT EXCEED 150°F (66°C). USE CARE WHEN HANDLING HAZARDOU S CHEMICALS.
REPLACEMENT PARTS HAVE BEEN INSTALLED ACCORDING TO DRAWING.
6300-2
6300-3
6300-4
6300
6300-5
6310
6300H
6300E
6310E
6300EH
PARTS
Red Hose - ½”I.D. x 25’
44-3RG
Black Hose - ½”I.D. x 6’
44-3-6
Blue Gun & Wand
40-14QD/292QD
Gray Gun & Wand
28-1QD & 292GQD
Backflow Preventor *
44-89-112
Metering Tip Kit
100-15K
Tubing And Foot Valve
Assembly
Ceramic Weight
61-107-2
Screw & Anchor Kit
66-54
Hose Clamp Kit
66-231
Hose Rack
44-6
* ASSE 1012 approved constant pressure backflow preventor.
1 1 1 1
1 1 1 1
1 1
1 1
1 1
1 1 1 1 1 1 1 1 1 1
2 2 2 2 2 1 2 2 1 2
2 2 2 2 2 1 2 2 1 2
1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1
I-1002 Pg. 2 of 12 Rev. G-40295 11/25/14
Page 3
DEMA RAPID FIRE MODELS
6300, 6300-2, 6300-3, 6300-4 6300-5, 6310, 6300H 6300E, 6300EH, &6310E
INSTRUCTION SHEET
2. INSTALLATION:
NOTE: ALL INSTALLATIONS MUST CONFORM TO LOCAL PLUMBING CODES
AND USE THE APPROVED BACKFLOW PREVENTORS.
WARNING: WATER SUPPLY PRESSURE MUST NOT EXCEED 125 PSI AND WATER
TEMPERATURE MUST NOT EXCEED 150°F (66°C). USE CARE WHEN HANDLING HAZARDOUS CHEMICALS.
A. MOUNTING AND WATER SUPPLY:
Mount in a convenient location using the screw and anchor kit provided
The water inlet is equipped with a female garden hose fitting. The fitting may be removed to permit direct connection to 1/4” NPT pipe.
WARNING: WATER SUPPLY PRESSURE MUST NOT EXCEED 125 PSI AND WATER
TEMPERATURE MUST NOT EXCEED 150°F (66°C).
B. OUTLE T CONNE CT ION:
Connect the discharge hose to the brass outlet garden hose fitting and squeeze the hose clamp
around the hose. Locate the position for the mounting screw, and mount the hose clamp to the wall using the remaining screw and anchor. Spray guns, spray nozzles or foaming wands may be used on the hose outlet. We recommend spray nozzles of 6 GPM or higher (at 40 psi). When a spray gun or nozzle is used, hose lengths must not exceed those shown in Table 1. Hoses, spray guns, and foam wands are available through DEMA. See the parts list on the last page for the various styles.
TABLE 1
Hose I.D. Max. Length
3/8" 1/2" 5/8" (or larger)
15 ft. 50 ft. 100 ft.
C. CHEMICAL SUPPLY:
WARNING: USE CARE WHEN HANDLING HAZARDOUS CHEMICALS.
Place the chemical container(s) in a convenient location not more than six feet below the RAPID
FIRE
(greater distances will reduce injection capabilities). The top of the chemical product container should never be higher than the RAPID FIRE. Cut vinyl tubes to any convenient length that will allow the tubes to reach the bottom of the container(s). Remove the screw (22) and knob (21), raise the hinged cover, and push the other tubing ends over the chemical inlet barbs located on the sides of the injector. Place the tubing ends with the foot valves into the chemical
containers.
I-1002 Pg. 3 of 12 Rev. G-40295 11/25/14
Page 4
DEMA RAPID FIRE MODELS
6300, 6300-2, 6300-3, 6300-4 6300-5, 6310, 6300H 6300E, 6300EH, &6310E
INSTRUCTION SHEET
3. CHEMICAL INDUCTION:
The chemical induction is controlled by metering tips screwed into the hose barb(s) located on the sides of assembly. The feed rates can be changed by using different sizes of metering tips. To select the proper size of metering tip for the desired dilution ratio, refer to Table 2 below.
TABLE 2
METERING TIP SELECTION CHART
FLUID DILUTION RATIOS WITH METERING TIP KIT (100-15K)
Metering
Tip Color
Tan Orange Turquoise Pink Clear Brown Red White Green Blue Yellow Black Purple Gray No Tip
1 cps 75 cps 200 cps
Oz/Gal mL/L Ratio Oz/Gal mL/L Ratio Oz/Gal mL/L Ratio
0.40 3.11 320-1 0.25 1.95 512-1 0.20 1.56 640-1
0.50 3.89 256-1 0.35 2.72 366-1 0.25 1.95 512-1
0.70 5.45 183-1 0.50 3.89 256-1 0.35 2.72 366-1
0.95 7.39 135-1 0.65 5.06 197-1 0.45 3.50 284-1
1.30 10.12 98-1 0.80 6.23 160-1 0.55 4.28 233-1
1.50 11.68 85-1 0.90 7.01 142-1 0.60 4.67 213-1
1.90 14.79 67-1 1.00 7.78 128-1 0.70 5.45 183-1
2.20 17.12 58-1 1.30 10.12 98-1 0.80 6.23 160-1
2.60 20.24 49-1 1.50 11.68 85-1 0.90 7.01 142-1
3.20 24.91 40-1 1.75 13.62 73-1 1.00 7.78 128-1
4.85 37.75 26-1 2.25 17.51 57-1 1.10 8.56 116-1
6.50 50.60 20-1 2.40 18.68 53-1 1.15 8.95 111-1
9.20 71.61 14-1 2.70 21.02 47-1 1.20 9.34 107-1
10.40 80.95 12-1 2.85 22.18 45-1 1.25 9.73 102-1
16.00 124.54 8-1 3.50 27.24 37-1 1.55 12.07 83-1
All injection ratios are based on 40 PSI inlet water pressure and a water flow rate of 2.7 GPM.
Injection Rates for Viscosities Shown
Note: Leaner dilutions are available using DEMA metering tip kit #100-15KU or capillary tip
#44-61P
4. OPERATION:
The RAPID FIRE permits the operator to select either chemical or clear water rinse by turning the selector knob. When using a spray gun or foaming wand, make sure that the gun on the end of the hose is in the full open position when inducting chemical.
I-1002 Pg. 4 of 12 Rev. G-40295 11/25/14
Page 5
DEMA RAPID FIRE MODELS
6300, 6300-2, 6300-3, 6300-4 6300-5, 6310, 6300H 6300E, 6300EH, &6310E
INSTRUCTION SHEET
5. TROUBLESHOOTING
CAUTION: TURN OFF WATER SUPPLY BEFORE SERVICING.
Symptom Probable Cause Remedy
Unit fails to draw chemical 1. The discharge hose is too long or
is the inside diameter too small
2. Gun or nozzle is sized incorrectly
3. Metering tip is blocked
4. Chemical hoses are kinked
5. Spray gun is not fully open
6. Injector is clogged
7. Foot valve is clogged
8. Spray nozzle is clogged
9. Chemical seals are damaged
10. Chemical check valve seals are
damaged
Steps on replacing chemical seals:
1. Turn knob to the off position and remove both the screw and knob
2. Remove the 2 screws that mount the assembly to the bracket.
1. See Table 1 for proper sizing.
2. Refer to section 2 B and resize
gun or nozzle accordingly
3. Remove tip and clean it
4. Replace hose
5. Adjust gun to fully open
6. Replace the injector
7. Remove foot valve and clean it.
8. Remove nozzle and clean it
9. Replace chemical seals (See steps
on replacing chemical seals).
10. Replace check valve seals (See
steps on replacing check valve seals)
Remove Screws
I-1002 Pg. 5 of 12 Rev. G-40295 11/25/14
Page 6
DEMA RAPID FIRE MODELS
6300, 6300-2, 6300-3, 6300-4 6300-5, 6310, 6300H 6300E, 6300EH, &6310E
INSTRUCTION SHEET
3. Remove the 2 screws from each elbow.
Remove all screws and washers from elbows.
4. Remove both elbows from assembly. Make sure O-rings are still attached to elbows.
5. Remove both chemical seals from the same openings the elbows were removed from and replace with new seals.
Chemical seals (Use a small flat head screw driver to help remove the seals)
6. Reassemble all parts listed in previous steps.
Steps on replacing check valve seals:
1. Refer back to the section above “Steps on replacing chemical seals” and perform steps 1-5.
I-1002 Pg. 6 of 12 Rev. G-40295 11/25/14
Page 7
DEMA RAPID FIRE MODELS
6300, 6300-2, 6300-3, 6300-4 6300-5, 6310, 6300H 6300E, 6300EH, &6310E
INSTRUCTION SHEET
2. Remove the gear retainer and then the gear.
Gear retainer
3. Using a flat head screw driver, remove the check valve body and o-ring. You might have to tap on the side of the assembly to knock loose the check valve. Be careful not to lose the check ball or spring when removing the check valve body.
Remove check valve body from here.
Check valve body, check ball, and spring.
4. Replace both inner and outer o-rings on check valve body and reassemble all components from all steps listed above. Note that smaller diameter end of the spring goes against the ball. See Detail A for assembly of the driver gear.
DETAIL A
SCALE 2:1
NOTE: REGISTER PINS ON GEARS MUST ALIGN AS SHOWN WITH KNOB IN THE "OFF" POSITION
CAUTION: WHEN SERVICING UNIT BE SURE THAT REPLACEMENT PARTS HAVE
BEEN INSTALLED ACCORDING TO THE DRAWING.
I-1002 Pg. 7 of 12 Rev. G-40295 11/25/14
Page 8
DEMA RAPID FIRE MODELS
6300, 6300-2, 6300-3, 6300-4 6300-5, 6310, 6300H 6300E, 6300EH, &6310E
INSTRUCTION SHEET
OVERALL DIMENSIONS:
Weight: 2.5 lb. (1.14 kg.):
RAPID FIRE
I-1002 Pg. 8 of 12 Rev. G-40295 11/25/14
Page 9
DEMA RAPID FIRE MODELS
6300, 6300-2, 6300-3, 6300-4 6300-5, 6310, 6300H 6300E, 6300EH, &6310E
INSTRUCTION SHEET
I-1002 Pg. 9 of 12 Rev. G-40295 11/25/14
Page 10
DEMA RAPID FIRE MODELS
6300, 6300-2, 6300-3, 6300-4 6300-5, 6310, 6300H 6300E, 6300EH, &6310E
INSTRUCTION SHEET
I-1002 Pg. 10 of 12 Rev. G-40295 11/25/14
ITEM
NO.
QTY DEMA NO. DESCRIPTION MATERIAL
1 1 63-1 Valve Body POLYPROPYLENE 2 1 65-10 Coupling BRASS 3 1 66-93 Inlet BRASS 4 1 100-38 Strainer Washer VINYL/SS 5 2 44-116-5 #8 HI-LO Screw x 5/8” Lg. STNLS. STL. 6 1 63-21 Water Seal Retainer POLYPROPYLENE 7 1 63-22 O-Ring AFLAS 8 1 63-9 Extension Spring STNLS. STL.
9 1 66-93-8 Water Seal EPDM 10 1 63-11 Plug POLYPROPYLENE 11 2 63-12 Gear Retainer POLYPROPYLENE 12 2 63-13 Detent POLYPROPYLENE 13 4 58-102 #6 HI-LO Screw X ¾” Lg. STNLS. STL. 14 2 63-14 Elbow POLYPROPYLENE 15 2 63-4 O-Ring AFLAS 16 1 24-24P7 Ball (.2188 Dia.) TEFLON 17 1 63-15 Check Valve Body POLYPROPYLENE 18 3 63-7 O-Ring AFLAS 19 1 63-23 Drive Gear POLYPROPYLENE 20 1 63-17 Driven Gear POLYPROPYLENE 21 1 63-18 Knob POLYPROPYLENE 22 1 58-60 #6 HI-LO Screw X ½” Lg. STNLS. STL. 25 1 20-1M-11RF Injector 2.7 GPM (Color, Gray) POLYPROPYLENE 26 1 63-3 O-Ring AFLAS 27 1 63-26 Quad Ring VITON
28* 1 63-19 Cap VINYL
29 2 66-93-7 Chemical Seal AFLAS 30 1 57-10-51A O-Ring AFLAS 41 1 25-29VA O-Ring VITON 42 1 63-24 Water Seal EPDM 43 1 63-25 Spring Washer STNLS. STL. 44 1 63-10 Spring HASTELLOY 45 4 29-17-3 Washers STNLS. STL.
* For 6310
Page 11
DEMA RAPID FIRE MODELS
6300, 6300-2, 6300-3, 6300-4 6300-5, 6310, 6300H 6300E, 6300EH, &6310E
INSTRUCTION SHEET
34
31
35
32
36
33
40
ITEM N0. DEMA NO. DESCRIPTION MATERIAL
37
38
39
31 100-12 Vinyl Tubing ¼”i.d. x 8’lg Vinyl
32 61-107-2 Ceramic Weight ¼”i.d. Ceramic
33 100-16V Foot Valve Assembly Polypropylene/Viton
292QD
Wand (for 1/4 turn valve gun #33)
Polypropylene
34
292GQD
Wand (for trigger handle gun #34)
Polypropylene
Stainless Steel With
35 40-14QD Spray gun (Blue Handle)
Insulated Rubber Handle
Metal and Plastic With
36 28-1QD Spray gun w/ Quick Disconnect
Insulated Rubber Handle
37 44-3-6 Hose Assy. Black ½”ID x 6’ lg. Black Rubber
38 44-3RG Hose Assy. Red ½”ID x 25’ lg. Red Rubber
39 44-89-112 Backflow Assy. w/ Garden Hose Fittings Brass
40 44-6 Hose Rack Stainless Steel
I-1002 Pg. 11 of 12 Rev. G-40295 11/25/14
Page 12
DEMA RAPID FIRE MODELS
6300, 6300-2, 6300-3, 6300-4 6300-5, 6310, 6300H 6300E, 6300EH, &6310E
INSTRUCTION SHEET
Return Policy
No merchandise may be returned for credit without DEMA Engineering Company’s written permission. Return Merchandise Authorization (RMA) number required in advance of return.
Warranty
DEMA products are warranted against defective material and workmanship under normal use and service for one year from the date of manufacture. This limited warranty does not apply to products that have a normal life shorter than one year or failure and damage caused by chemicals, corrosion, improper voltage supply, physical abuse or misapplication. Rubber and synthetic parts such as “O”-rings, diaphragms, squeeze-tubes and gaskets are considered expendable and are not covered under warranty. This warranty is extended only to the original buyer of DEMA products. If products are altered or repaired without prior approval of DEMA, this warranty will be void.
Defective units or parts should be returned to the factory with transportation prepaid. If inspection shows them to be defective, they will be repaired or replaced without charge. F.O.B. factory DEMA assumes no liability for damages. Return merchandise authorization number to return units for repair or replacement must be granted in advance of return.
I-1002 Pg. 12 of 12 Rev. G-40295 11/25/14
Loading...