DEMA SPRAY FOAM MODEL 294CTDM
INSTALLATION INSTRUCTIONS
1. PARTS
A. Foamer assembly
B. Plastic tubing with strainer and ceramic weight
C. Metering Tips (specified on order)
D. Outlet hose 3/4" ID x 25' lg. (optional)
E. Shutoff valve (optional)
2. INSTALLATION
A. Mounting: Attach plastic tubing to detergent inlet barb an d sl id e
ceramic weight over tubing.
B. Water inlet is 3/4" garden hose swivel.
C. Air inlet is 1/4" NPT
D. Foam outlet is 3/4" garden hose. Connect shutoff valve to end
of hose. See Table 1 for hose limitations.
Table 2
Viscosity (cps)
Maximum
(Oz/Gal)
3. OPERATION
WARNING: USE CARE WHEN HANDLING
HAZARDOUS CHEMICAL S.
Open shutoff valve at end of hose. Turn on air
supply; set pressure at 40 psi. Turn on water supply.
1 75 200 500
34.3 20.4 10.5 6.5
Pressure
(psi)
Water
Flow
(G.P.M.)
Air Flow
(SCFM)
Table 1
Minimum PressuresHose Size and
Length
Water Air
25' of 3/4" ID 40 psi 40 psi
50' of 3/4" ID 50 psi 40 psi
25' of 1/2" ID 60 psi 40 psi
Table 3
40 50 60 80
1.4 1.6 1.7 2.0
3.5 4.2 4.8 6.1
4. ADJUSTMENT
Chemical feed rates are controlled by metering tips screwed into the detergent inlet barb. Tips are identified by number or co lo r. Oth er
tips are available from Dema (Part No. 61-9-specify size). To in crease dry ness of f oam , raise air pressure 5 psi. Repeat if necessary.
5. SERVICING
CAUTION: TURN OF F AIR AND WATER SUP PLIES BEFO RE SERVICING
If flow surges and unit fails to make foam:
A. Is the outlet hose too small or too long?
B. Is there sufficient water and air pressure? At least 30 psi is requried.
C. Does detergent contain a foaming agent?
D. Is the foamer outlet attac hed to a manifold with too few or too small nozzles? They should have a combined water rating of 20
G.P.M. @ 40 psi.
If unit stops operating:
A. Is the foot strainer clogged? Lift from drum and clean.
B. Is the detergent check valve clogged? Remove the (4) screws in the squar e knob. Remove knob to inspect and clean check
valve ball, spring, and o-ring.
C. Is the metering tip clogged? Remove from inlet barb and clean.
DEMA SPRAY FOAM MODEL 294CTDM
INSTALLATION INSTRUCTIONS
I-145 Pg. 1 of 3
Rev. A0600

Table 4
Induction Rates for Vis cosities Shown
Metering Tip
Color
Clear 0.84 152-1 0.65 197-1 0.45 284-1 0.30 427-1
Purple 1.35 95-1 1.10 116-1 0.90 142-1 0.60 213-1
Yellow 2.40 53-1 2.00 64-1 1.50 85-1 1.10 116-1
Green 4.20 30-1 3.40 38-1 2.65 48-1 2.10 61-1
Pink 5.25 24-1 4.50 28-1 3.45 37-1 2.60 49-1
Turquoise 9.40 14-1 7.25 18-1 5.45 23-1 3.70 35-1
Black 11.75 11-1 8.80 15-1 6.35 20-1 4.20 30-1
Gray 14.50 9-1 10.80 12-1 7.75 17-1 4.75 27-1
Red 18.00 7-1 13.20 10-1 8.30 15-1 5.00 26-1
Blue 20.60 6-1 14.70 9-1 8.65 14.8-1 5.20 25-1
1 cps 75 cps 200 cps 500 cps
Oz/Gal Ratio Oz/Gal Ratio Oz/Gal Ratio Oz/Gal Ratio
Brown 24.10 5-1 16.15 8-1 9.30 14-1 5.50 23-1
White 27.50 4.7-1 17.80 7-1 9.70 13-1 5.70 22-1
Orange 30.00 4.3-1 18.50 6.9-1 10.10 12.7-1 5.85 21.9-1
Lt. Blue 32.00 4-1 18.90 6.8-1 10.20 12.5-1 6.00 21-1
Tan 32.50 3.9-1 19.25 6.6-1 10.40 12.3-1 6.25 20.5-1
None 34.25 3.7-1 20.45 6-1 10.60 12-1 6.50 20-1
All induction rates are based on 40 psi water pressure and 40 psi air pressure.
RETURNS: NO M ERCHANDISE MAY BE RETURNED FOR CREDIT WITHOUT DEMA’S WRITTEN PERMISSION.
RETURN MERCHANDISE AUTHORIZATION NUMBER REQUIRED IN ADVANCE OF RETURN.
WARRANTY: DEMA products are warranted against defectiv e material and workmanship under norm al use and service for one y ear from the
date of manufacture. This limited warranty does not apply to any products which have a normal life shorter than one year or
failure and dam age caused by chemicals, corrosion, improper voltage supply, physical abuse, or misapplication. Rubber and
synthetic rubber parts such as “o”- rings, diaphragms, squeeze tubing and gaskets are conside red expen da ble a nd are not co vere d
under warranty. This warranty is extended only to the original buyer of DEMA products. If products a re altered or repaired
without prior approval of DEMA, this warranty will be void.
Defective units or parts should be returned to the factory with transportation prepaid. If inspection shows them to be defective,
they wil l be repaired or replaced without charge, F.O.B. factory . DEMA assumes no liability f or damages. Retu rn m erc h an di se
authorization number, to return units for repair or replacement, must be granted in advance of return.
I-145 Pg. 2 of 3
Rev. A0600

SPRAY FOAM-MODEL 294 CDM & 294CTDM
34-1
93-14
24-8-8S
23-24
93-1
93-32
93-31
93-30-1V
24-24S
93-6
21-8
25-29
23-34-3
23-9
23-10
23-11
61-107-1
93-30-2
93-38
93-2
100-12LS
93-28
24-11L
93-29
90-15
23-26CDM
23-26CTDM
23-7
PART N0.
21-8
23-7
23-9
23-10
23-11
23-24
23-26CDM
23-26CTDM
23-34-3 CHECK VALVE CORE
24-8-8S
24-11L
24-24S
24-63
25-29
30-2V
34-1
61-9
61-107-1
90-15
AIR CHECK VALVE O-RING
MACHINE SCREW (4 REQD)
CHECK VALVE SPRING
CHECK VALVE BALL (9/32 DIA STNLS. STL.)
CHECK VALVE O-RING
METERING SCREW W/ O-RING (294CDM ONLY)
METERING KNOB & BUNG ASSEMBLY (294 CDM ONLY)
METERING KNOB & BUNG ASSEMBLY (294 CDM ONLY)
WATER NOZZLE W/ O-RING
FOOT STRAINER
STAINLESS STEEL BALL 1/4" (294CDMT ONLY)
CHECK VALVE REPAIR KIT
METERING KNOB O-RING
BALL 5/16" RUBBER
INLET HOSE ADAPTER
METERING TIP-SPECIFY COLOR (294CDMT ONLY)
CERAMIC WEIGHT
OUTLET SHUTOFF VALVE
DESCRIPTION
61-9
93-45
PART N0.
93-1
93-2
93-6
93-14
93-28
93-29
93-30-1V
93-30-2
93-31
93-32
93-38
93-45
100-12LS
93-17-4
93-24
93-25
ACCESSORY
93-24
93-25
93-17-4
DESCRIPTION
PRESSURE REGULATOR
PRESSURE GAGE
AIR CHECK VALVE SPRING
3/4" ID X 25' LG. OUTLET HOSE
RETAINER SCREW
SPRING
BALL 1/4 DIA
BALL 5/16" DIA
ADAPTER
FOAMER BODY
STAINLESS STEEL BALL 5/16" (294CDMT ONLY)
SNAP RING
1/2" OD VINYL TUBING X 8'3 1/2' LG.
ACCESSORIES
4' LG. SPRAY WAND W/ SOLID STREAM NOZZLE
NOZZLE W/ SOLID STREAM (SUPPLIED)
NOZZLE W/ 40° ANGLE