DEMA®259BAC DRAIN MASTER Jr.
INSTALLATION INSTRUCTION SHEET
I-737 Pg 1 of 7 Rev C-31502 7/14/06
Page 2
DEMA®259BAC DRAIN MASTER Jr.
INSTALLATION INSTRUCTION SHEET
Summary
The 259BAC Drain Master is designed to feed chemicals into drains and grease traps to break up grease, detergent build up and eliminate odors. All programming is done by use of a set of DIP switches that determine the various times and amount of chemical to be dispensed.
Please read all instructions before proceeding with Drain Master installation.
Survey Location
Determine a location to hang the Drain Master on a wall near the drain or grease trap to be supplied with the chemical product. The Drain Master can be hung on the wall by use of the supplied wall bracket kit. The location should provide access to 120V, 208, 230/240V 50/60Hz electrical power.
Electrical Hookup:
All installations must be in accordance with city, county, state or provincial electrical codes and be performed by a certified electrician. For questions, please contact local licensed electrical contractor.
1. BEFORE GOING ANY FURTHER, AL L ELECT RICAL POWER MUST BE TURNED OFF TO THE CIRCUIT THAT IS TO BE USED FOR THIS INSTALLATION. LOCKOUT AND TAG PROCEDURES SHOULD BE OBSERVED WHEN INSTALLING THIS DEVICE. NEVER OPEN THE DRAIN MASTER UNLESS POWER HAS BEEN TURNED OFF. ONLY USE ELECTRICAL CODE APPROVED INSULATED WIRING AND ELECTRICAL FIXTURES WITH THIS INSTALLATION.
2. Connect the power to t he Drain Master. The Dra in Master will accept 120V AC, 208VAC or 230/240VAC 50/60Hz.
3. Locate the power terminal block inside the Drain Master enclosure. Connect the “return line” to the appropriate terminal block position based on supply voltage. The black “common” wire goes to “line”. The “earth gro und” wire must be connected to the terminal block position labeled “GND”. The power line should be secured by use of a proper electrical fitting thro ugh an access hole in the Drain Mast er enclosure.
4. Install a 9 volt radio battery on the circuit board for memory backup, this allows for retention of the clock and other functions in the event of power failures. Note: Alkaline batteries are recommended for longer service life.
I-737 Pg 2 of 7 Rev C-31502 7/14/06
Page 3
DEMA®259BAC DRAIN MASTER Jr.
INSTALLATION INSTRUCTION SHEET
Tubing Connections
Cut off the proper lengths of LDPE tubing that will reach from the container of product to the inlet of the Drain Master pump and the outlet of the pump to the drain or grease trap.
Insert the chemical supply tubing into t he end of the ¼” ID JG fitt ing located on the left side of the pump. The JG fitting must be inserted completely in order to ensure a good seal. The other end of the chemical supply tubing can be connect ed to the 10” PVC pickup tube that has been supplied. This should be done by slipping the LDPE tubing through the compression nut and sleeve and into the threaded end of the pickup tube u ntil LDPE tubing is about ¼” from the bottom of the pickup tube. The pickup tube can be placed in gallon containers of chemical products. If the pickup tube is not used, the supply tube should be properly secured to the supply container to assure that chemical product is delivered.
Insert the outlet tubing into the end of the ¼” ID JG fitting located on the right side of the pump. The JG fitting must be inserted completely in order to ensure a goo d seal outlet tubing must be secured into drain or grease trap to assure that chemical product is properly delivered. It is suggested to use a 1/8” NPT male x ¼” compression fitt ing when fitting discharge into the side of a drainpipe.
. The other end of the
Programming:
Open the cover on the Drain Master. All of the DIP switches should be visible on the control board on the backside of the cover. All of these switches must be in the “off” position to begin
programming.
Time Set: Find the DIP switch that corresponds to the closest hour of the current time.
There are 12 DIP switches for AM and 12 for PM. After finding the correct switch flip it to the “on” position. The “time set” LED will go out.
Feed Time: Using the same switches set the hours in which the Drain Master should
operate by switching the appropriate switch to the “on” position.
Note: If the DIP switch that was set for the “time set” is not a desirable “feed time”, simply turn that switch to the “off” position. But not until at least one feed time has been selected. This will insure tha t the “time se t” will not be lost .
Dosage: There are a series of 6 DIP sw itches that are labeled “dosage”. The number
labe led ne xt to e ach swit ch ind icat es the nu mber o f ounc es to be d ispe nsed. Example: switch 2 will dispense 2 ounces of product. These may be added together for higher doses. Example: Switches 5 and 6 in the “on” position will dispense 11 ounces of product. The maximum is 21 ounces at each “feed time” that has been set.
Reprogram: Flip all the DIP switches to “off” position.
I-737 Pg 3 of 7 Rev C-31502 7/14/06
Page 4
DEMA®259BAC DRAIN MASTER Jr.
INSTALLATION INSTRUCTION SHEET
Priming
After installation is complete the pump and tubing will need to be primed so that chemical product will be delivered when the Drain Master is running. This is simply done by pressing and releasing the prime button on the front of the Drain Master; the pump should begin to run. The pump will run for the amount of dose that has been set.
Note: At any time the Drain Master pump can be shut off by simply pushing the prime button again.
1
26
12
14
I-737 Pg 4 of 7 Rev C-31502 7/14/06
Page 5
DEMA®259BAC DRAIN MASTER Jr.
INSTALLATION INSTRUCTION SHEET
Replacement Parts
Item
No.
1 81-61-4 El ec trica l Enclo sure Kit 1 2 81-41 Electrical Enclosure Cover Kit (81-29-2 Captive
3 81-6 El ec trica l Enclo sure H inge Kit 2 4 25-121-1 Drain Master Electro nic Control Board 1
5 81-20-2 Control Board Scr ew 3 11 81-29-2 Captive Screw for Electrical Enclosure Co ver 2 12 81-47-1 ½” Hole Plug 1 14 25-66C Gear Motor Assembly 1 20 L715-1 Drain Master Label (front face label) 1 21 80-70 40VA Transformer 1 22 25-139-4 Fused Terminal Block and Bracket assembly (fuse
23 25-138-1 Fuse, 5mm x 20mm 1A, 250V 1 24 44-116-1 #8 x ½” Hi-Lo Screw 1 25 44-116-2 #8 x 3/8” Hi-Lo Screw 1 26 81-32-24 Grounding Wire Assembly 1 27 81-14-15 Female Q uick Connect 1
See the diagram on the previous page to aid in identifying parts.
DEMA Part No. Description Amount
Scr ew s inc lu ded in kit )
included in terminal block)
Required
1
1
25-126-4 INSTALLATION KIT PARTS (NOT SHOWN ON DRAWING)
DEMA PART NO. DESCRIPTION QTY.
81-16-1 Tie Wrap 8” lg. 4 81-182-1 ¼” x ¼” JG Union 2 25-68-20 20 Ft of ¼” LDPE Tubing (white) 1 80-66 10” Pick Up Tube Assembly 1 81-1 Wall Bracket Kit 1 66-122 #8 Screw and Anchor Kit 1
I-737 Pg 5 of 7 Rev C-31502 7/14/06
Page 6
DEMA®259BAC DRAIN MASTER Jr.
INSTALLATION INSTRUCTION SHEET
REPLACEMENT PARTS
NO. DEMA PART NO. DESCRIPTION QTY.
1 81-128-1 Pump Base 1 2 81-177-1 Squeeze Tube 1 3 81-172-1 Ro ller Ass e mbl y 1 4 81-199-1 Pump Bore and Label Assembly 1 5 81-63-1 Mounting Plate 1 6 44-124-2 Scr ew 4
1oz. 81-17-1 Silic one Lube (not shown)
I-737 Pg 6 of 7 Rev C-31502 7/14/06
Page 7
DEMA®259BAC DRAIN MASTER Jr.
INSTALLATION INSTRUCTION SHEET
RED
GND LINE
120 V RET
208 V RET
240 V RET
1A. 250V
FUSE
DIP SWITCHES
DOSE SETTING
DIP SWITCHES TIME SETTING
BLACK
20 RPM GEARMOTOR
12V WALL TRANSFORMER
POWER JACK
9V BATTER Y
HOLDER
WIRING SCHEMATIC
Warranty DEMA products are warranted against defective material and workmanship under normal use and service for one year from th e date of manufacture. This limited warranty does n ot apply to any products, which have a normal life shorter than one year or failure and damage caused by chemicals, corrosion, improper voltage supply, physical abuse, or misapplication. Rubber and synthetic rubber parts such as “O” rings, diaphragms, squeeze tubing and gaskets are considered expendable and are not covered under warranty. This warranty is extended only to the original buyer of DEMA products. If products are altered or repaired without prior approval of DEMA, this warranty is void.
Return Policy No merchandise may be returned for credit without the written permission of DEMA Engineering Company. A return merchandise authorization (RMA) number is required in advance of return.
I-737 Pg 7 of 7 Rev C-31502 7/14/06