
LED FLOODLIGHT
FITTING INSTRUCTIONS
These instructions are for the Déluce Lighting Protector 8 advanced floodlight range: 10W, 30W, 50W, 80W and 120W :
DL2MGFL10WBLKB, DL2MGFL10WBLKDL, DL2MGFL10WBLKG, DL2MGFL10WBLKR, DL2MGFL10WBLKWW, DL2MGFL10WWHB,
DL2MGFL10WWHDL, DL2MGFL10WWHG, DL2MGFL10WWHR, DL2MGFL10WWHWW, DL2MGFL30WBLKDL, DL2MGFL30WBLKRGB,
DL2MGFL30WBLKWW, DL2MGFL50WBLKDL, DL2MGFL50WBLKWW, DL2MGFL80WBLKB, DL2MGFL80WBLKDL, DL2MGFL80WBLKG,
DL2MGFL80WBLKR, DL2MGFL80WBLKWW, DL2MGFL120WBLKB, DL2MGFL120WBLKDL, DL2MGFL120WBLKG, DL2MGFL120WBLKR
and DL2MGFL120WBLKWW.
100-240V
IMPORTANT INSTALLATION INFORMATION
• Installation should be carried out in accordance with the
latest edition of the IEE Wiring Regulations (BS7671) and
taking into consideration the latest Building Regulations. If in
doubt, consult a qualified electrician.
• Important: Ensure that ALL electrical connections are tight
with no loose strands including factory made connections.
• Before commencing any installation or maintenance
work, ensure electricity is switched off at the mains.
• Please take note of the maximum rated voltage for your
floodlight.
PLEASE NOTE THIS FLOODLIGHT IS MULTI-VOLTAGE - AN
APPROPRIATE 110V STEP-DOWN TRANSFORMER MUST
BE USED WHEN USING THE FLOODLIGHT ON SITE.
• Please take note of the IP (Ingress Protection) rating of your
floodlight when deciding location.
• Always allow sufficient slack in the supply cable in order
to remove the floodlight from its position for any future
maintenance.
• Care must be taken for installations where the lens or bezel
may come into contact with bare skin.
• Please take note of the nearest illuminated surface as detailed
on the product label.
LED
IP 65
B C
TECHNICAL DATA
Type: Marine Grade LED Floodlights
Voltage: AC100V ~ 265V
LED power: 10W, 30W, 50W, 80W, 120W
Number of LEDs: 1 piece - 2 pieces
Lumens*: 90lm / W
Protection class: IP65
Colour temperature*:
• Daylight 5500K ±200K
• Warm white 3200K ±200K
Cri: 80
Average life: 50,000 hours
Operating temperature: -25 ° C ~ +40 ° C
* Does not apply to single colour or RGB versions
PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION
LEAVE A COPY FOR THE USER/MAINTENANCE ENGINEER FOR FUTURE REFERENCE
(120W only)
We recommend this fitting is installed by a qualified Electrician.
A
PRODUCT DIMENSIONS
Dimension A Dimension B Dimension C
10W 179mm 139mm 49mm
30W 292mm 234mm 68mm
50W 292mm 234mm 68mm
80W
120W 430mm 360mm 100mm
400mm 310mm 87mm
www.delucelighting.com
DEL0423b/May_2015[issue_2] Page 1 of 2

FITTING INSTRUCTIONS
• Always check whether the site of the installation
can support the weight of the floodlight.
For safety, 1.5 times the weight of the floodlight
is recommended. If you are unsure do not install.
LED FLOODLIGHT
GENERAL INSTALLATION - SAFETY
1. Please make sure you are safe when working at height.
2. Employ the latest safety regulations and procedures to
ensure the safe installation of this floodlight.
3. When positioning your floodlight out of doors please
take note that outdoor electrical installations should
be installed by a qualified Electrician. Correct circuit
protection for all exterior electrical services should
include a residual current device (RCD), also known
as an earth leakage circuit breaker (ELCB). This simple
device ensures that the power is cut off immediately; it
detects a leakage of current to earth, which indicates an
electrical fault which is potentially threatening to life.
Observe these few Simple rules and keep your outdoor
electrical installation safe.
INSTALLATION INSTRUCTIONS
1. Select the required position for the floodlight.
2. Remove the mounting bracket from the floodlight.
3. Fix the mounting bracket to the mounting surface with
appropriate screws and wall plugs, sufficient to take the
weight of the fitting.
4. Replace the main body of the floodlight to the bracket,
ensuring that cables are not trapped between the base
mounting bracket and the floodlight,
5. Connect the floodlight to the mains supply, with an
appropriate junction box or connection fitting, making
sure any exposed connections and joints are sufficiently
weatherproofed. When using with 110V supply make
sure the correct CEE plug is fitted to connect to the
transformer.
6. Then make the electrical connections as follows:
LIVE - (Red or Brown) to a terminal marked L
NEUTRAL - (Black or Blue) to a terminal marked N
MOUNTING BRACKET
RETAINING/ADJUSTMENT
BOLT
MOUNTING
BRACKET
7. Ensure that there are no exposed conductors, loose or
trapped cable strands.
8. Adjust the angle of the floodlight by the retaining/
adjustment bolt, making sure the bolt is re-tightened.
9. Switch on the power supply to test.
MAINTENANCE
1. Please make sure the power is switched off before
starting any maintenance.
2. In order to maintain good even light coverage, the glass
cover should be cleaned regularly.
3. For good heat dissipation the floodlight housing should
also be cleaned regularly.
4. Please take care when cleaning the glass or floodlight
housing.
DO NOT USE water or cleaning solutions, cleaning should
preferably be done with a clean dry cloth.
EARTH - (Green/Yellow) to a terminal marked
WARNING - THIS FITTING MUST BE EARTHED
This product is guaranteed in the EU for a period of 5 years from the date of purchase. The guarantee is invalid in the case of improper use, installation,
tampering, removal of the QC date label, installation in an improper working environment or installation not according to the current edition of the IEE Wiring
Regulations (BS 7671). Should this product fail during the guarantee period it will be replaced free of charge, subject to correct installation and return of the
faulty unit. Déluce Lighting does not accept responsibility for any installation costs associated with the replacement of this product. Your statutory rights are
not affected. Déluce Lighting reserves the right to alter specifications without prior notice.
PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION
LEAVE A COPY FOR THE USER/MAINTENANCE ENGINEER FOR FUTURE REFERENCE
www.delucelighting.com
GUARANTEE
We recommend this fitting is installed by a qualified Electrician.
DEL0423b/May_2015[issue_2] Page 2 of 2