Deltrol Controls C Frame Solenoids, D Frame Solenoids, Tubular Solenoids, Magnetic Latching Solenoids Data Sheet

C
D
Deltrol
CONTROLS
Deltrol Controls Solenoid Data Sheets
Table of Contents
C Frame Solenoids
C-4..............................................................................2
C-5..............................................................................6
C-15..........................................................................26
D Frame Solenoids
D-2............................................................................30
D-3HD......................................................................34
D-4............................................................................38
D-4HD......................................................................42
D-11..........................................................................46
D-17..........................................................................50
D-22..........................................................................54
D-28..........................................................................58
D-30..........................................................................62
D-50..........................................................................66
D-70..........................................................................70
D-90..........................................................................74
PS-75........................................................................78
Tubular Solenoids
MED 12x1.500......................................................82
MED 16x1.125......................................................86
MED 16x2.000......................................................90
MED 19x2.700......................................................94
MED 24x1.700......................................................98
MED 24x2.400....................................................102
Magnetic Latching Solenoids
D4-ML...................................................................106
D26-ML.................................................................109
D30-ML.................................................................112
C-4
C
D
Deltrol
CONTROLS
C-FRAME SOLENOID
Two position linear solenoid with C-frame construction.
Features
• Economical construction
• AC solenoids and DC solenoids available
• Tape Wrapped coils on most models
• UL approval on many models
Electrical Specications
Coil Voltages 6, 12, 24, 120, 240 VAC | 6, 12, 24, 110 VDC
Coil Power
Coil Termination Wire leads 24 AWG
Duty Cycle Continuous, Intermittent, Pulse (see standard part numbers on page 4)
Coil Treatment Tape Wrapped
Insulation Class Class A Rating - 105ºC (221°F) Max.
Dielectric Strength
Mechanical Specications
Size 0.768” (L) x 0.687” (W) x 0.765” (H) (See dimensional drawing on page 2)
Forces See force curves on page 3
Plunger Diameter 0.3125”
Plunger Guide Material Plastic
Mounting 2X #6-32 UNC-2B Mounting Holes
Weight Plunger - 0.25 oz., Total - 1 oz.
Life Expectancy 250,000 Cycles (Dependent on load conditions)
Agency Approval
4.5 VA Continuous, 12 VA Intermittent, 45 VA Pulse
3.5 Watts Continuous, 8 Watts Intermittent, 35 Watts Pulse
30 Volts and Under: 500 VRMS Over 30 Volts: 1000 VRMS plus 2X rated voltage for 1 minute
UL File No. E57982 For Continuous Duty UL File No. E74443 For Insulation Systems S105
All dimensions in Inches
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
1 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
C-4
Dimensional View
Units: Inches [mm]
D
C
Deltrol
CONTROLS
UNLESS OTHERWISE SPECIFIED
INCHES ± .015
(MILLIMETERS 0.38)
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
2 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
C-4
Force Curves
AC Continuous Duty - 4.5 VA DC Continuous Duty - 3.5 Watts
D
C
Deltrol
CONTROLS
AC Intermittent Duty - 12 VA
AC Pulse Duty- 45 VA
DC Intermittent Duty - 8 Watts
DC Pulse Duty - 35 Watts
Standard intermittent duty cycle at nominal voltage is 25%, with one (1) minute maximum “ON” and three (3) minutes minimum “OFF” in a repetitive cycle. Standard Pulse duty cycle is 10% with 100 milliseconds “ON” and 900 milliseconds “OFF”. NOTE: Approx 36 sq. in. Heat Sink Required
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
3 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
C-4
Standard Part Numbers
D
C
Deltrol
CONTROLS
Parts No. Voltage Duty Cycle Power
53645-80 6 VAC
53645-81 12 VAC 14.9
53645-83 24 VAC 60.5
53645-94 120 VAC 1530
53645-97 240 VAC 6120
53646-80 6 VAC
53646-81 12 VAC 6.3
53646-83 24 VAC 25.4
53646-94 120 VAC 664
53646-97 240 VAC 2660
53787-80 6 VAC
53787-81 12 VAC 2.34
53787-83 24 VAC 9.2
53787-94 120 VAC 231
53787-97 240 VAC 932
53648-80 6 VDC
53648-81 12 VDC 42
53648-83 24 VDC 167
53648-93 110 VDC 3400
53649-80 6 VDC
53649-81 12 VDC 17.4
53649-83 24 VDC 71.0
53649-93 110 VDC 1460
53752-80 6 VDC
53752-81 12 VDC 4.3
53752-82 24 VDC 17.4
53752-84 110 VDC 363
Continuous 4.5 VA
Intermittent
Pulse 45 VA
Continuous
Intermittent
Pulse
12 VA
3.5
Watts
Watts
35
Watts
Resistance
(Ohms)
3.7
1.55
0.58
10.5
4.34
8
1.06
Operation
Pull 23 2.4 0.8 0 0
Pull 45 5 1.7 0 0
Pull 90 15 5 0 0
Pull 18 2.2 0.8 0 0
Pull 27 5 2 0 0
Pull 46 15 6 0 0
Typical Force (oz). 100% Voltage, 77°, Stroke @
0.000” 0.125” 0.250” 0.500” 0.750”
(*) Normally Stocked Non stocked items require a minimum order
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
4 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
C-5
C
D
Deltrol
CONTROLS
C-FRAME SOLENOID
Two position linear solenoid with C-frame construction.
Features
• Economical construction
• AC solenoids and DC solenoids available
• Tape Wrapped coils on most models
• UL approval on many models
Electrical Specications
Coil Voltages 6, 12, 24, 120, 240 VAC | 6, 12, 24, 110 VDC
Coil Power
Coil Termination Wire leads 22 AWG (standard)
Duty Cycle Continuous, intermittent, pulse (see standard part numbers on page 4)
Coil Treatment Tape Wrapped
Insulation Class Class A Rating - 105ºC (221°F) Max.
Dielectric Strength
Mechanical Specications
Size 0.969” (L) x 0.734” (W) x 0.812” (H) (See dimensional drawing on page 2)
Forces See page 3 for force curves
Plunger Diameter 0.3125”
Plunger Guide Material Plastic
Mounting 2X #4-40 UNC-2B Mounting Holes
Weight Plunger - 0.317 oz., Total - 1.5 oz.
Life Expectancy 250,000 Cycles (Dependent on load conditions)
Agency Approval
4.7 VA Continuous, 14 VA Intermittent, 47 VA Pulse,
3.7 Watts Continuous, 11 Watts Intermittent, 42 Watts Pulse
30 Volts and Under: 500 VRMS Over 30 Volts: 1000 VRMS plus 2X rated voltage for 1 minute
UL File No. E57982 For Continuous Duty UL File No. E74443 For Insulation Systems S105
All dimensions in Inches
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
1 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
C-5
Dimensional View
Units: Inches [mm]
D
C
Deltrol
CONTROLS
UNLESS OTHERWISE SPECIFIED
INCHES ± .015
(MILLIMETERS 0.38)
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
2 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
C-5
Force Curves
AC Continuous Duty - 4.7 VA DC Continuous Duty - 3.7 Watts
D
C
Deltrol
CONTROLS
AC Intermittent Duty - 14 VA
AC Pulse Duty - 47 VA
DC Intermittent Duty - 11 Watts
DC Pulse Duty - 42 Watts
Standard intermittent duty cycle at nominal voltage is 25%, with one (1) minute maximum “ON” and three (3) minutes minimum “OFF” in a repetitive cycle. Standard Pulse duty cycle is 10% with 100 milliseconds “ON” and 900 milliseconds “OFF”. NOTE: Approx 36 sq. in. Heat Sink Required
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
3 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
C-5
Standard Part Numbers
D
C
Deltrol
CONTROLS
Parts No. Voltage Duty Cycle Power
53747-80 6 VAC
53747-81 12 VAC 13.1
53747-82 24 VAC 52.1
53747-84 120 VAC 1273
53747-85 240 VAC 5100
53747-86 6 VAC
53747-87 12 VAC 4.76
53747-88 24 VAC 19.1
53747-90 120 VAC 480
53747-91 240 VAC 1940
53747-92 6 VAC
53747-93 12 VAC 1.77
53747-94 24 VAC 7
53747-96 120 VAC 183
53747-97 240 VAC 738
53746-80 6 VDC
53746-81 12 VDC 41.6
53746-82 24 VDC 168
53746-84 110 VDC 3265
53746-86 6 VDC
53746-87 12 VDC 13.1
53746-88 24 VDC 52.1
53746-90 110 VDC 1125
53746-92 6 VDC
53746-93 12 VDC 3.23
53746-94 24 VDC 13.1
53746-96 110 VDC 282
Continuous 4.7 VA
Intermittent 14 VA
Pulse 47 VA
Continuous
Intermittent
Pulse
3.7
Watts
11
Watts
42
Watts
Resistance
(ohms)
3.23
1.15
0.445
10.4
3.23
0.8
Operation
Pull 24 3.5 2 0 0
Pull 50 9.5 5.5 0 0
Pull 86 25 15 0 0
Pull 25 3 1.5 0 0
Pull 38 12 5 0 0
Pull 62 34 19 0 0
Typical Force (oz). 100% Voltage, 77°, Stroke @
0.000” 0.125” 0.250” 0.500” 0.750”
(*) Normally Stocked Non stocked items require a minimum order
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
4 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
C-6
C
D
Deltrol
CONTROLS
C-FRAME SOLENOID
Two position linear solenoid with C-frame construction.
Features
• Economical construction
• AC solenoids and DC solenoids available
• Encapsulated coils on most models
• UL approval on many models
Electrical Specications
Coil Voltages 6, 12, 24, 120, 240 VAC | 6, 12, 24, 110, 220 VDC
Coil Power
Coil Termination
Duty Cycle Continuous, intermittent, pulse (see standard part numbers on page 4)
Coil Treatment Encapsulated
Insulation Class Class A Rating - 105ºC (221°F) Max. (standard)
Dielectric Strength 30 Volts and Under: 500 VRMS
Mechanical Specications
Size 1.126” (L) 0.860” (W) 0.839” (H) (See dimensional drawing on page 2)
Forces See force curves on page 3
Plunger Diameter 0.3125
Plunger Guide Material Plastic
Mounting 4X #6-32 UNC-2B Mounting Holes
Weight Plunger - 0.317 oz., Total - 1.5 oz.
Life Expectancy 250,000 Cycles (Dependent on load conditions)
Agency Approvals
6.8 VA Continuous, 19.6 VA Intermittent, 68 VA Pulse
4.7 Watts Continuous, 12 Watts Intermittent, 45 Watts Pulse
0.187” Quick Connect/Solder Lug (standard)
0.250” Quick Connect/Solder Lug (optional) Wire Leads (optional with tape wrapped coil)
Class F Rating - 155ºC (266°F) Max. (optional)
Over 30 Volts: 1000 VRMS plus 2X rated voltage for 1 minute
UL File No. E57982 For Continuous Duty UL File No. E74443 For Insulation Systems
S105, S130, S130D, S130D1, S155D
All dimensions in Inches
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
1 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
C-6
Dimensional View
Units: Inches [mm]
D
C
Deltrol
CONTROLS
UNLESS OTHERWISE SPECIFIED
INCHES ± .015
(MILLIMETERS 0.38)
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
2 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
C-6
Force Curves
D
C
Deltrol
CONTROLS
AC Continuous Duty - 6.8 VA
AC Intermittent Duty - 19.6 VA
DC Continuous Duty - 4.7 Watts
DC Intermittent Duty - 12 Watts
AC Pulse Duty- 68 VA
Standard intermittent duty cycle at nominal voltage is 25%, with one (1) minute maximum “ON” and three (3) minutes minimum “OFF” in a repetitive cycle. Standard Pulse duty cycle is 10% with 100 milliseconds “ON” and 900 milliseconds “OFF”. NOTE: Approx 36 sq. in. Heat Sink Required
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
DC Pulse Duty - 45 Watts
3 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
C-6
Standard Part Numbers
D
C
Deltrol
CONTROLS
Parts No. Voltage Duty Cycle Power
53687-80 6 VAC
53687-81 12 VAC 7.6
53687-83 24 VAC 30.6
53687-94* 120 VAC 776
53687-97 240 VAC 3070
53688-80 6 VAC
53688-81 12 VAC 3.2
53688-83 24 VAC 13
53688-94* 120 VAC 327
53688-97 240 VAC 1370
53743-80 6 VAC
53743-81 12 VAC 1.18
53743-82 24 VAC 5
53743-83 120 VAC 124
53743-84 240 VAC 493
53685-80 6 VDC
53685-81 12 VDC 30.6
53685-83* 24 VDC 124
53685-93 110 VDC 2670
53685-97 220 VDC 11200
53686-80 6 VDC
53586-81 12 VDC 13
53686-83* 24 VDC 50.8
53686-93 110 VDC 1011
53686-97 220 VDC 4050
53745-80 6 VDC
53745-81 12 VDC 3.2
53745-82 24 VDC 13
53745-84 110 VDC 271
53745-85 220 VDC 1140
Continuous 6.8 VA
Intermittent 19.6 VA
Pulse 68 VA
Continuous
Intermittent
Pulse
4.7
Watts
12
Watts
45
Watts
Resistance
(Ohms)
1.92
0.78
0.3
7.6
3.2
0.78
Operation
Pull 33 5.9 4 2 0
Pull 57 13 9 4.5 0
Pull 95 32 24 10 0
Pull 38 4 1.9 0.5 0
Pull 50 11 5 2 0
Pull 68 34 17 6 0
Typical Force (oz). 100% Voltage, 77°, Stroke @
0.000” 0.125” 0.250” 0.500” 0.750”
(*) Normally Stocked Non stocked items require a minimum order
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
4 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
C-7
C
D
Deltrol
CONTROLS
CFRAME SOLENOID
Two position linear solenoid with C-frame construction.
Features
• Economical construction
• AC solenoids and DC solenoids available
• Encapsulated coils on most models
• UL approval on many models
Electrical Specications
Coil Voltages 6, 12, 24, 120, 240 VAC | 6,12, 24, 110 VDC
Coil Power
Coil Termination
Duty Cycle Continuous, intermittent and pulse (see standard part numbers on page 4)
Coil Treatment Encapsulated (tape wrapped optional)
Insulation Class Class A Rating - 105ºC (221ºF) Max.
Dielectric Strength
Mechanical Specications
Size 1.140” (L) 1.062” (W) 1.025” (H)
Forces See page 3 for force curves
Plunger Diameter 0.375”
Plunger Guide Material Plastic
Mounting 2X #10-32 UNF-2B Mounting Holes
Weight Plunger - 0.56 oz., Total - 2.5 oz.
Life Expectancy 250,000 Cycles (Dependent on load conditions)
Agency Approvals
7.8 VA Continuous, 21 VA Intermittent, 78 VA Pulse 5 Watts Continuous, 11.5 Watts Intermittent, 50 Watts Pulse
.187 quick connect terminals (standard) Wire leads optional with tape wrapped coil
30 Volts and Under: 500 VRMS Over 30 Volts: 1000 VRMS plus 2X rated voltage for 1 minute
UL File No. E57982 For Continuous Duty UL File No. E74443 For Insulation Systems S105
All dimensions in Inches
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
1 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
C-7
Dimensional View
Units: Inches [mm]
D
C
Deltrol
CONTROLS
UNLESS OTHERWISE SPECIFIED
INCHES ± .015
(MILLIMETERS 0.38)
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
2 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
C-7
Force Curves
D
C
Deltrol
CONTROLS
AC Continuous Duty - 7.8 VA
AC Intermittent Duty - 21 VA
DC Continuous Duty - 5 Watts
DC Intermittent Duty - 11.5 Watts
AC Pulse Duty- 78 VA
Standard intermittent duty cycle at nominal voltage is 25%, with three (3) minutes maximum “ON” and nine (9) minutes minimum “OFF” in a repetitive cycle. Standard Pulse duty cycle is 10% with 100 milliseconds “ON” and 900 milliseconds “OFF”. NOTE: Approx 36 sq. in. Heat Sink Required
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
DC Pulse Duty - 50 Watts
3 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
C-7
Standard Part Numbers
D
C
Deltrol
CONTROLS
Parts No. Voltage Duty Cycle Power
53637-80 6 VAC
53637-81 12 VAC 4.92
53637-83 24 VAC 20.1
53637-94* 120 VAC 509
53637-97 240 VAC 2140
53638-80 6 VAC
53638-81 12 VAC 2.14
53638-83 24 VAC 8.81
53638-94* 120 VAC 220
53638-97 240 VAC 875
53639-80 6 VAC
53639-81 12 VAC 0.766
53639-83 24 VAC 3.12
53639-94 120 VAC 81.6
53639-97 240 VAC 330
53634-80 6 VDC
53634-81 12 VDC 29.1
53634-83* 24 VDC 118
53634-93 110 VDC 2300
53635-80 6 VDC
53635-81 12 VDC 12.6
53635-83* 24 VDC 50.5
53635-93 110 VDC 1060
53636-80 6 VDC
53636-81 12 VDC 2.96
53636-83 24 VDC 11.5
53636-93 110 VDC 220
Continuous 7.8 VA
Intermittent 21 VA
Pulse 78 VA
Continuous
Intermittent
Pulse
Watts
11.5
Watts
50
Watts
Resistance
(Ohms)
1.23
0.533
0.193
7.38
5
3.12
0.728
Operation
Pull 42 9 7 4 0
Pull 66 20 16 8 0
Pull 110 52 42 21 0
Pull 42 6.5 3 1 0
Pull 60 16 8 2.5 0
Pull 93 60 40 15 0
Typical Force (oz). 100% Voltage, 77° F, Stroke @
0.000” 0.125” 0.250” 0.500” 0.750”
(*) Normally Stocked Non stocked items require a minimum order
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
4 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
C-8
C
D
Deltrol
CONTROLS
C-FRAME SOLENOID
Two position linear solenoid with C-frame construction.
Features
• Economical construction
• AC solenoids and DC solenoids available
• Encapsulated coils on most models
• UL approval on many models
Electrical Specications
Coil Voltages 6, 12, 24, 120, 240 VAC | 6, 12, 24, 110 VDC
Coil Power
Coil Termination
Duty Cycle Continuous, intermittent and pulse (see standard part numbers on page 4)
Coil Treatment Encapsulated (tape wrapped optional)
Insulation Class Class A Rating - 105ºC (221ºF) Max
Dielectric Strength
Mechanical Specications
Size 1.187” (L) x 1.280” (W) x 1.261” (H)
Forces See page 3 for force curves
Plunger Diameter 0.375”
Plunger Guide Material Plastic
Mounting 2X #6-32 UNC-2B Mounting Holes
Weight Plunger - 0.56 oz., Total - 3.5 oz.
Life Expectancy 250,000 Cycles (Dependant on load conditions)
Agency Approvals
9.5 VA Continuous, 25 VA Intermittent, 95 VA Pulse
6.5 Watts Continuous, 16 Watts Intermittent, 65 Watts Pulse
.187” quick connect terminals (standard) .250” quick connect terminals (optional) Wire leads optional with tape wrapped coil
30 Volts and Under: 500 VRMS Over 30 Volts: 1000 VRMS plus 2X rated voltage for 1 minute
UL File No. E57982 For Continuous Duty UL File No. E74443 For Insulation Systems S105
All dimensions in Inches
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
1 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
C-8
Dimensional View
Units: Inches [mm]
D
C
Deltrol
CONTROLS
UNLESS OTHERWISE SPECIFIED
INCHES ± .015
(MILLIMETERS 0.38)
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
2 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
C-8
Force Curves
AC Continuous Duty - 9.5 VA DC Continuous Duty - 6.5 Watts
D
C
Deltrol
CONTROLS
AC Intermittent Duty - 25 VA
AC Pulse Duty - 95 VA
DC Intermittent Duty - 16 Watts
DC Pulse Duty - 65 Watts
Standard intermittent duty cycle at nominal voltage is 25%, with three (3) minutes maximum “ON” and nine (9) minutes minimum “OFF” in a repetitive cycle. Standard Pulse duty cycle is 10% with 100 milliseconds “ON” and 900 milliseconds “OFF”. NOTE: Approx 36 sq. in. Heat Sink Required
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
3 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
C-8
Standard Part Numbers
D
C
Deltrol
CONTROLS
Parts No. Voltage Duty Cycle Power
53712-80 6 VAC
53712-81 12 VAC 3.3
53712-82 24 VAC 13.8
53712-84* 120 VAC 346
53712-85 240 VAC 1400
53712-86 6 VAC
53712-87 12 VAC 1.44
53712-88 24 VAC 5.8
53712-90* 120 VAC 151
53712-91 240 VAC 614
53712-92 6 VAC
53712-93 12 VAC 0.57
53712-94 24 VAC 2.25
53712-96 120 VAC 60.3
53712-97 240 VAC 242
53713-80 6 VDC
53713-81 12 VDC 23
53713-82* 24 VDC 93.3
53713-84 110 VDC 2010
53713-86 6 VDC
53713-87 12 VDC 9.3
53713-88 24 VDC 37.5
53713-90 110 VDC 782
53713-92 6 VDC
53713-93 12 VDC 2.25
53713-94 24 VDC 9.3
53713-96 110 VDC 196
Continuous 9.5 VA
Intermittent 25 VA
Pulse 95 VA
Continuous
Intermittent
Pulse
6.5
Watts
16
Watts
65
Watts
Resistance
(Ohms)
0.82
.36
0.14
5.8
2.25
0.57
Operation
Pull 50 12 8 6 0
Pull 90 25 20 15 0
Pull 134 53 42 30 0
Pull 65 12 5.5 2.5 0
Pull 79 27 14 5 0
Pull 103 74 53 24 0
Typical Force (oz). 100% Voltage, 77° F, Stroke @
0.000” 0.125” 0.250” 0.500” 0.750”
(*) Normally Stocked Non stocked items require a minimum order
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
4 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
C-9
C
D
Deltrol
CONTROLS
CFRAME SOLENOID
Two position linear solenoid with C-frame construction.
Features
• Economical construction
• AC solenoids and DC solenoids available
• Encapsulated coils on most models
• UL approval on many models
Electrical Specications
Coil Voltages 24, 120, 240 VAC | 6, 12, 24, 110 VDC
Coil Power
Coil Termination
Duty Cycle Continuous, intermittent and pulse (see standard part numbers on page 4)
Coil Treatment Encapsulated (tape wrapped optional)
Insulation Class Class A Rating - 105ºC (221ºF) Max. (standard)
Dielectric Strength
Mechanical Specications
Size 1.062” (L) x 1.375” (W) x 1.413” (H)
Forces See force curves on page 3
Plunger Diameter .500”
Plunger Guide Material Plastic
Mounting 2X #10-32 UNF-2B Mounting Holes
Weight Plunger - 0.90 oz., Total - 5.0 oz.
Life Expectancy 250,000 Cycles (Dependent on load conditions)
Agency Approval
13.7 VA Continuous, 52 VA Intermittent, 137 VA Pulse
8.6 Watts Continuous, 15.5 Watts Intermittent, 86 Watts Pulse
.187” quick connect terminals (standard) .250” quick connect terminals (optional) Wire leads optional with tape wrapped coil
Class F Rating - 155ºC (311ºF)Max. (optional)
30 Volts and Under: 500 VRMS Over 30 Volts: 1000 VRMS plus 2X rated voltage for 1 minute
UL File No. E57982 For Continuous Duty UL File No. E74443 For Insulation Systems S105, S130, S130D, S130D1, S155D
All dimensions in Inches
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
1 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/01/11
C-9
Dimensional View
Units: Inches [mm]
D
C
Deltrol
CONTROLS
UNLESS OTHERWISE SPECIFIED
INCHES ± .015
(MILLIMETERS 0.38)
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
2 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/01/11
C-9
Force Curves
D
C
Deltrol
CONTROLS
AC Continuous Duty - 13.7 VA
*AC Intermittent Duty - 52 VA
DC Continuous Duty - 8.6 Watts
DC Intermittent Duty - 15.5 Watts
AC Pulse Duty - 137 VA
Standard intermittent duty cycle at nominal voltage is 25%, with three (3) minutes maximum “ON” and nine (9) minutes minimum “OFF” in a repetitive cycle. Standard Pulse duty cycle is 10% with 100 milliseconds “ON” and 900 milliseconds “OFF”. NOTE: Approx 36 sq. in. Heat Sink Required *AC intermittent duty winding based on 20% duty cycle with one “1” minute maximum “ON” time.
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
DC Pulse Duty - 86 Watts
3 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/01/11
C-9
Standard Part Numbers
D
C
Deltrol
CONTROLS
Parts No. Voltage Duty Cycle Power
53673-83 24 VAC
Continuous 13.7 VA
53673-97 240 VAC 960
53674-83 24 VAC
Intermittent 52 VA
53674-97 240 VAC 342
53675-94 120 VAC
53675-97 240 VAC 143
53676-80 6 VDC
53676-81 12 VDC 16.5
53676-83 24 VDC 66.5
53676-93 110 VDC 1430
53677-81 12 VDC
53677-93 110 VDC 788
53677-83 24 VDC
53678-93 110 VDC 143
Pulse 137 VA
Continuous
Intermittent
Pulse
8.6
Watts
15.5
Watts
86
Watts
Resistance
(Ohms)
9.3
3.3
37.6
4.1
9.3
6.7
Operation
Pull 59 17 14 10 0 53673-94* 120 VAC 240
Pull 137 45 36 27 0 53674-94* 120 VAC 84.1
Pull 181 85 75 57 0
Pull 75 18 10 3 0
Pull 84 30 17 6 053677-83 24 VDC 37.6
Pull 156 105 76 30 0
Typical Force (oz). 100% Voltage, 77°, Stroke @
0.000” 0.125” 0.250” 0.500” 0.750”
(*) Normally Stocked Non stocked items require a minimum order
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
4 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/01/11
C-15
C
D
Deltrol
CONTROLS
C-FRAME SOLENOID
Two position linear solenoid with C-frame construction.
Features
• Economical construction
• AC solenoids and DC solenoids available
• Encapsulated coils on most models
• UL approval on many models
Electrical Specications
Coil Voltages 6, 12, 24, 120, 240 VAC | 6, 12, 24, 110 VDC
Coil Power
Coil Termination
Duty Cycle
Coil Treatment Encapsulated (tape wrapped optional)
Insulation Class
Dielectric Strength
Mechanical Specications
Size 1.729” (L) x 0.844” (W) x 0.942” (H)
Forces See force curves on page 3
Plunger Diameter 0.313”
Plunger Guide Material Plastic
Mounting 2X #6-32 UNC-2B Mounting Holes
Weight Plunger - 0.48 oz., Total - 3.3 oz.
Life Expectancy 250,000 Cycles (Dependent on load conditions)
Agency Approval
12 VA Continuous, 26 VA Intermittent, 120 VA Pulse
7.4 Watts Continuous, 19 Watts Intermittent, 74 Watts Pulse
.187” quick connect terminals (standard) Wire leads optional with tape wrapped coil
Continuous, intermittent and pulse (see standard part numbers on page 4)
Class A Rating - 105ºC (221ºF) Max. (standard) Class F Rating - 155ºC (311ºF) Max. (optional)
30 Volts and Under: 500 VRMS Over 30 Volts: 1000 VRMS plus 2X rated voltage for 1 minute
UL File No. E57982 For Continuous Duty UL File No. E74443 For Insulation Systems S105, S130, S130D, S130D1, S155D
All dimensions in Inches
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
1 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
C-15
Dimensional View
Units: Inches [mm]
D
C
Deltrol
CONTROLS
UNLESS OTHERWISE SPECIFIED
INCHES ± .015
(MILLIMETERS 0.38)
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
2 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
C-15
Force Curves
D
C
Deltrol
CONTROLS
AC Continuous Duty - 12 VA
AC Intermittent Duty - 26 VA
DC Continuous Duty - 7.4 Watts
DC Intermittent Duty - 19 Watts
AC Pulse Duty - 120 VA
Standard intermittent duty cycle at nominal voltage is 25%, with three (3) minutes maximum “ON” and nine (9) minutes minimum “OFF” in a repetitive cycle. Standard Pulse duty cycle is 10% with 100 milliseconds “ON” and 900 milliseconds “OFF”. NOTE: Approx 36 sq. in. Heat Sink Required
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
DC Pulse Duty - 74 Watts
3 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
C-15
Standard Part Numbers
D
C
Deltrol
CONTROLS
Parts No. Voltage Duty Cycle Power
53679-80 6 VAC
53679-81 12 VAC 2.9
53679-83 24 VAC 12
53679-94* 120 VAC 302
53679-97 240 VAC 1210
53680-80 6 VAC
53680-81 12 VAC 1.6
53680-83 24 VAC 6.5
53680-94 120 VAC 166
53680-97 240 VAC 670
53681-80 6 VAC
53681-81 12 VAC 0.64
53681-83 24 VAC 2.54
53681-94 120 VAC 65
53681-97 240 VAC 264
53682-80 6 VDC
53682-81 12 VDC 19.2
53682-83* 24 VDC 77.3
53682-93 110 VDC 1690
53683-80 6 VDC
53683-81 12 VDC 7.5
53683-83* 24 VDC 30.6
53683-93 110 VDC 638
53684-80 6 VDC
53684-81 12 VDC 1.83
53684-83 24 VDC 7.5
53684-93 110 VDC 161
Continuous 12 VA
Intermittent 26 VA
Pulse 120 VA
Continuous
Intermittent
Pulse
7.4
Watts
19
Watts
74
Watts
Resistance
(Ohms)
0.71
0.4
0.16
4.75
1.83
0.47
Operation
Pull 41 11 8 7 4
Pull 75 17 14 12.5 7.5
Pull 102 44 35 30 21
Pull 53 16 7.5 3 1.5
Pull 59 32 17 7 3
Pull 70 33 23 13 7
Typical Force (oz). 100% Voltage, 77°, Stroke @
0.000” 0.125” 0.250” 0.500” 0.750”
(*) Normally Stocked Non stocked items require a minimum order
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
4 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
D-2
C
D
Deltrol
CONTROLS
D-FRAME SOLENOID
Two position linear solenoid with D-frame construction.
Features
• Balance of cost and performance
• AC solenoids and DC solenoids available
• Encapsulated coils on most models
• UL approval on many models
Electrical Specications
Coil Voltages
Coil Power
Coil Termination
Duty Cycle
Coil Treatment Encapsulated (tape wrapped optional)
Insulation Class
Dielectric Strength
Mechanical Specications
Size 1.558“ (L) x 1.437” (W) x 1.625” (H) (See dimensional drawing on page 2)
Forces See page 3 for force curves
Plunger Diameter 0.4375”
Plunger Guide Material Plastic
Mounting 8X #8-32 UNC-2B Mounting Holes
Weight Plunger - 1.2 oz., Total - 10 oz.
Life Expectancy 250,000 Cycles (Dependent on load conditions)
Agency Approval
6, 12, 24,120, 240 VAC | 6, 12, 24, 110 VDC
13 VA Continuous, 59 VA Intermittent, 135 VA Pulse, 11 Watts Continuous, 29 Watts Intermittent, 115 Watts Pulse
.187” Quick Connect Terminals (standard) .250” Quick Connect Terminals (optional) Wire leads optional with tape wrapped coil
Continuous, intermittent and pulse duty available (see standard part numbers on page 4)
Class A Rating - 105ºC (221ºF) Max. (standard) Class F Rating - 155ºC (311ºF) Max. (optional)
30 Volts and Under: 500 VRMS Over 30 Volts: 1000 VRMS plus 2X rated voltage for 1 minute
UL File No. E57982 For Continuous Duty UL File No. E74443 For Insulation Systems S105, S130, S130D, S130D1, S155D
All dimensions in Inches
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
1 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/08/11
D-2
Dimensional View
Units: Inches [mm]
C
D
UNLESS OTHERWISE SPECIFIED
(MILLIMETERS 0.38)
Deltrol
CONTROLS
INCHES ± .015
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
2 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/08/11
D-2
Force Curves
AC Continuous Duty - 13 VA DC Continuous Duty - 11 Watts
D
C
Deltrol
CONTROLS
AC Intermittent Duty - 59 VA
AC Pulse Duty- 135 VA
DC Intermittent Duty - 29 Watts
DC Pulse Duty - 115 Watts
Standard intermittent duty cycle at nominal voltage is 25%, with three (3) minutes maximum “ON” and nine (9) minutes minimum “OFF” in a repetitive cycle. Standard Pulse duty cycle is 10% with 100 milliseconds “ON” and 900 milliseconds “OFF”. NOTE: Approx 36 sq. in. Heat Sink Required
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
3 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/08/11
D-2
Standard Part Numbers
D
C
Deltrol
CONTROLS
Parts No. Voltage Duty Cycle Power
53729-80 6 VAC
53729-81 12 VAC 1.58
53729-82 24 VAC 6.4
53729-84* 120 VAC 164
53729-85 240 VAC 673
53729-87 12 VAC
53729-88 24 VAC 1.83
53729-90* 120 VAC 47.0
53729-91 240 VAC 191
53729-93 12 VAC
53729-94 24 VAC 1.22
53729-96 120 VAC 31.7
53729-97 240 VAC 128.2
53728-80 6 VDC
53728-81* 12 VDC 13.6
53728-82* 24 VDC 54.7
53728-84 110 VDC 1100
53728-86 6 VDC
53728-87* 12 VDC 4.92
53728-88* 24 VDC 20.0
53728-90 110 VDC 432
53728-92 6 VDC
53728-93 12 VDC 1.22
53728-94 24 VDC 4.92
53728-96 110 VDC 106
Continuous 13 VA
Intermittent 59 VA
Pulse 135 VA
Continuous
Intermittent
Pulse
11
Watts
29
Watts
115
Watts
Resistance
(Ohms)
0.40
0.45
0.303
3.34
1.22
.303
Operation
Pull 64 17 15 13 6
Pull 131 50 44 40 21
Pull 180 94 80 72 41
Pull 107 50 24 9 4
Pull 127 98 55 20 9
Pull 158 165 140 70 30
Typical Force (oz). 100% Voltage, 77° F, Stroke @
0.000” 0.125” 0.250” 0.500” 0.750”
(*) Normally Stocked Non stocked items require a minimum order
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
4 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/08/11
D-3HD
C
D
Deltrol
CONTROLS
D-FRAME SOLENOID
Two position linear solenoid with D-frame construction.
Features
• Balance of cost and performance
• AC solenoids and DC solenoids available
• Encapsulated coils on most models
• UL approval on many models
Electrical Specications
Coil Voltages 6, 12, 24, 120, 240 VAC | 6, 12, 24, 110 VDC
Coil Power
Coil Termination
Duty Cycle
Coil Treatment Encapsulated (tape wrap optional)
Insulation Class
Dielectric Strength
Mechanical Specications
Size 1.737” (L) x 1.437” (W) x 1.626” (H) (See dimensional drawing on page 2)
Forces See page 3 for force curves
Plunger Diameter 0.500”
Plunger Guide Material Plastic
Mounting 8X #8-32 UNC-2B Mounting Holes
Weight Plunger - 1.76 oz., Total - 11 oz.
Life Expectancy 250,000 Cycles (Dependent on load conditions)
Agency Approval
21 VA Continuous, 120 VA Intermittent, 210 VA Pulse, 11 Watts Continuous, 27 Watts Intermittent, 110 Watts Pulse
.187” Quick Connect Terminals (standard) .250” Quick Connect Terminals (optional) Wire leads optional with tape wrapped coil
Continuous, intermittent and pulse duty available (see standard part numbers on page 4)
Class A Rating - 105ºC (221ºF) Max. (standard) Class F Rating - 155ºC (311ºF) Max. (optional)
30 Volts and Under: 500 VRMS Over 30 Volts: 1000 VRMS plus 2X rated voltage for 1 minute
UL File No. E57982 For Continuous Duty UL File No. E74443 For Insulation Systems S105, S130, S130D, S130D1, S155D
All dimensions in Inches
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
1 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/08/11
D-3HD
Dimensional View
Units: Inches [mm]
D
C
Deltrol
CONTROLS
UNLESS OTHERWISE SPECIFIED
INCHES ± .015
(MILLIMETERS 0.38)
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
2 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/08/11
D-3HD
Force Curves
D
C
Deltrol
CONTROLS
AC Continuous Duty - 21 VA
AC Intermittent Duty - 120 VA
DC Continuous Duty - 11 Watts
DC Intermittent Duty - 27 Watts
AC Pulse Duty - 210 VA
Standard intermittent duty cycle at nominal voltage is 25%, with three (3) minutes maximum “ON” and nine (9) minutes minimum “OFF” in a repetitive cycle. Standard Pulse duty cycle is 10% with 100 milliseconds “ON” and 900 milliseconds “OFF”. NOTE: Approx 36 sq. in. Heat Sink Required
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
DC Pulse Duty - 110 Watts
3 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/08/11
D-3HD
Standard Part Numbers
D
C
Deltrol
CONTROLS
Parts No. Voltage Duty Cycle Power
53733-80 6 VAC
53733-81 12 VAC 1.05
53733-82 24 VAC 4.21
53733-84* 120 VAC 109
53733-85 240 VAC 446
53733-87 12 VAC
53733-88 24 VAC 1.05
53733-90* 120 VAC 27.6
53733-91 240 VAC 109
53733-94 24 VAC
53733-97 240 VAC 73.8
53732-80 6 VDC
53732-81* 12 VDC 12.8
53732-82* 24 VDC 51.5
53732-84 110 VDC 1100
53732-86 6 VDC
53732-87* 12 VDC 5.27
53732-88* 24 VDC 21.4
53732-90 110 VDC 463
53732-92 6 VDC
53732-93 12 VDC 1.31
53732-94 24 VDC 5.27
53732-96 110 VDC 109
Continuous 21 VA
Intermittent 120 VA
Pulse 210 VA
Continuous
Intermittent
Pulse
11
Watts
27
Watts
110
Watts
Resistance
(Ohms)
0.26
0.26
0.70
3.13
1.31
.323
Operation
Pull 87 23 20 18 10
Pull 205 79 65 58 34
Pull 254 115 100 90 6353733-96 120 VAC 18.0
Pull 153 74 30 10 4
Pull 165 134 70 26 10
Pull 207 215 180 90 40
Typical Force (oz). 100% Voltage, 77° F, Stroke @
0.000” 0.125” 0.250” 0.500” 0.750”
(*) Normally Stocked Non stocked items require a minimum order
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
4 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/08/11
D-4
C
D
Deltrol
CONTROLS
D-FRAME SOLENOID
Two position linear solenoid with D-frame construction.
Features
• Balance of cost and performance
• AC solenoids and DC solenoids available
• Encapsulated coils on most models
• UL approval on many models
Electrical Specications
Coil Voltages
Coil Power
Coil Termination
Duty Cycle Continuous, Intermittent and pulse (see standard part numbers on page 4)
Coil Treatment Encapsulated (tape wrap optional)
Insulation Class
Dielectric Strength
Mechanical Specications
Size 1.996” (L) x 1.437” (W) x 1.625” (H) (See dimensional drawing on page 2)
Forces See page 3 for force curves
Plunger Diameter 0.4375”
Plunger Guide Material Plastic
Mounting 8X #8-32 UNC-2B Mounting Holes
Weight Plunger - 1.63 oz., Total - 12 oz.
Life Expectancy 250,000 Cycles (Dependent on load conditions)
Agency Approval
6, 12, 24, 120, 240 VAC | 6, 12, 24, 110 VDC
10 VA Continuous, 59 VA Intermittent, 100 VA Pulse,
11.5 Watts Continuous, 47 Watts Intermittent, 105 Watts Pulse
.187” Quick Connect Terminals (standard) .250” Quick Connect Terminals (optional) Wire leads optional with tape wrapped coil
Class A Rating - 105ºC (221ºF) Max. (standard) Class F Rating - 155ºC (311ºF) Max. (optional)
30 Volts and Under: 500 VRMS Over 30 Volts: 1000 VRMS plus 2X rated voltage for 1 minute
UL File No. E57982 For Continuous Duty UL File No. E74443 For Insulation Systems S105, S130, S130D, S130D1, S155D
All dimensions in Inches
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
1 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/08/11
D-4
Dimensional View
Units: Inches [mm]
D
C
Deltrol
CONTROLS
UNLESS OTHERWISE SPECIFIED
INCHES ± .015
(MILLIMETERS 0.38)
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
2 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/08/11
D-4
Force Curves
AC Continuous Duty - 10 VA DC Continuous Duty - 11.5 Watts
D
C
Deltrol
CONTROLS
AC Intermittent Duty - 59 VA
AC Pulse Duty- 100 VA
DC Intermittent Duty - 47 Watts
DC Pulse Duty - 105 Watts
Standard intermittent duty cycle at nominal voltage is 25%, with three (3) minutes maximum “ON” and nine (9) minutes minimum “OFF” in a repetitive cycle. Standard Pulse duty cycle is 10% with 100 milliseconds “ON” and 900 milliseconds “OFF”. NOTE: Approx 36 sq. in. Heat Sink Required
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
3 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/08/11
D-4
Standard Part Numbers
D
C
Deltrol
CONTROLS
Parts No. Voltage Duty Cycle Power
53718-80 6 VAC
53718-81 12 VAC 1.55
53718-82 24 VAC 6.25
53718-84* 120 VAC 163
53718-85 240 VAC 665
53718-87 12 VAC
53718-88 24 VAC 1.55
53718-90* 120 VAC 41.0
53718-91 240 VAC 163
53718-94 24 VAC
53718-97 240 VAC 107
53717-80 6 VDC
53717-81* 12 VDC 12.3
53717-82* 24 VDC 50.0
53717-84 110 VDC 1070
53717-86 6 VDC
53717-87* 12 VDC 3.01
53717-88* 24 VDC 12.3
53717-90 110 VDC 261
53717-92 6 VDC
53717-93 12 VDC 1.36
53717-94 24 VDC 5.48
53717-96 110 VDC 107
Continuous 10 VA
Intermittent 59 VA
Pulse 100 VA
Continuous
Intermittent
Pulse
11.5
Watts
47
Watts
105
Watts
Resistance
(Ohms)
0.384
.384
1.01
3.01
0.744
0.337
Operation
Pull 50 10 9 10 11
Pull 123 38 33 36 41
Pull 155 62 52 59 6553718-96 120 VAC 26.1
Pull 112 65 32 12 8
Pull 134 123 90 50 30
Pull 155 157 122 80 55
Typical Force (oz). 100% Voltage, 77° F, Stroke @
0.000” 0.125” 0.250” 0.500” 0.750”
(*) Normally Stocked Non stocked items require a minimum order
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
4 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/08/11
D-4HD
C
D
Deltrol
CONTROLS
D-FRAME SOLENOID
Two position linear solenoid with D-frame construction.
Features
• Balance of cost and performance
• AC solenoids and DC solenoids available
• Encapsulated coils on most models
• UL approval on many models
Electrical Specications
Coil Voltages 12, 24, 120, 240 VAC | 6, 12, 24, 110 VDC
Coil Power
Coil Termination
Duty Cycle
Coil Treatment Encapsulated (tape wrapped optional)
Insulation Class
Dielectric Strength
Mechanical Specications
Size 2.175” (L) x 1.437” (W) x 1.625” (H) (See dimensional drawing on page 2)
Forces See force curves on page 3
Plunger Diameter 0.500”
Plunger Guide Material Plastic
Mounting 8X #8-32 UNC-2B Mounting Holes
Weight Plunger - 2.5 oz., Total - 13.3 oz
Life Expectancy 250,000 Cycles (Dependent on load conditions)
Agency Approval
31 VA Continuous, 145 VA Intermittent, 310 VA Pulse
11.5 Watts Continuous, 38 Watts Intermittent, 115 Watts Pulse
0.187” Quick Connect Terminals (standard)
0.250” Quick Connect Terminals (optional) Wire Leads (optional with tape wrapped coil)
Continuous, intermittent and pulse (see standard part numbers on page 4)
Class A Rating - 105º C Max. (221°F) (standard) Class F Rating - 155º C Max. (311°F) (optional)
30 Volts and Under: 500 VRMS Over 30 Volts: 1000 VRMS plus 2X rated voltage for 1 minute
UL File No. E57982 For Continuous Duty UL File No. E74443 For Insulation Systems S105, S130, S130D, S130D1, & S155D
All dimensions in Inches
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
1 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/08/11
D-4HD
Dimensional View
Units: Inches [mm]
D
C
Deltrol
CONTROLS
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
2 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
UNLESS OTHERWISE SPECIFIED
INCHES ± .015
(MILLIMETERS 0.38)
Rev 07/08/11
D-4HD
Force Curves
AC Continuous Duty - 31 VA DC Continuous Duty - 11.5 Watts
D
C
Deltrol
CONTROLS
AC Intermittent Duty - 145 VA
AC Pulse Duty - 310 VA
DC Intermittent Duty - 38 Watts
DC Pulse Duty - 115 Watts
Standard intermittent duty cycle at nominal voltage is 25%, with three (3) minutes maximum “ON” and nine (9) minutes minimum “OFF” in a repetitive cycle. Standard Pulse duty cycle is 10% with 100 milliseconds “ON” and 900 milliseconds “OFF”. NOTE: Approx 36 sq. in. Heat Sink Required
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
3 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/08/11
D-4HD
Standard Part Numbers
D
C
Deltrol
CONTROLS
Parts No. Voltage Duty Cycle Power
53720-81 12 VAC
53720-82 24 VAC 2.38
53720-84* 120 VAC 61.1
53720-85 240 VAC 247
53720-88 24 VAC
53720-91 240 VAC 71.8
53720-94 12 VAC
53720-97 240 VAC 48.2
53719-80 6 VDC
53719-81* 12 VDC 11.7
53719-82* 24 VDC 48.2
53719-84 110 VDC 1033
53719-86 6 VDC
53719-87* 12 VDC 3.75
53719-88* 24 VDC 15.2
53719-90 110 VDC 328
53719-92 6 VDC
53719-93 12 VDC 1.25
53719-94 24 VDC 5.10
53719-96 110 VDC 105
Continuous 31 VA
Intermittent 145 VA
Pulse 310 VA
Continuous
Intermittent
Pulse
11.5
Watts
38
Watts
115
Watts
Resistance
(Ohms)
0.588
0.689
0.453
2.88
0.924
0.316
Operation
Pull 92 23 20 23 27
Pull 192 70 58 65 75 53720-90* 120 VAC 17.7
Pull 254 125 105 108 12553720-96 120 VAC 11.7
Pull 141 85 41 15 9
Pull 163 135 95 48 25
Pull 201 210 175 105 62
Typical Force (oz). 100% Voltage, 77° F, Stroke @
0.000” 0.125” 0.250” 0.500” 0.750”
(*) Normally Stocked Non stocked items require a minimum order
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
4 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/08/11
D-11
C
D
Deltrol
CONTROLS
D-FRAME SOLENOID
Two position linear solenoid with D-frame construction.
Features
• Balance of cost and performance
• AC solenoids and DC solenoids available
• Encapsulated coils on most models
• UL approval on many models
Electrical Specications
Coil Voltages 6, 12, 24, 120, 240 VAC | 6, 12, 24, 110 VDC
Coil Power
Coil Termination
Duty Cycle
Coil Treatment Encapsulated (tape wrap optional)
Insulation Class
Dielectric Strength
Mechanical Specications
Size 1.851” (L) x 0.938” (W) x 1.190” (H) (See dimensional drawing on page 2)
Forces See force curve tables on page 3
Plunger Diameter 0.3125”
Plunger Guide Material Plastic
Mounting 4X #6-32 UNC-2B Mounting Holes
Weight Plunger - 0.65 oz., Total - 5.0 oz.
Life Expectancy 250,000 Cycles (Dependent on load conditions)
Agency Approvals
12.5 VA Continuous, 39 VA Intermittent, 125 VA Pulse 8 Watts Continuous, 19 Watts Intermittent, 80 Watts Pulse
.187” Quick Connect Terminals (standard) Wire leads optional with tape wrapped coil
Continuous, intermittent and pulse duty available (see standard parts on page 4
Class A Rating - 105ºC (221ºF) Max. (standard) Class F Rating - 155ºC (311ºF) Max. (optional)
30 Volts and Under: 500 VRMS Over 30 Volts: 1000 VRMS plus 2X rated voltage for 1 minute
UL File No. E57982 For Continuous Duty UL File No. E74443 For Insulation Systems S105, S130, S130D, S130D1, S155D
All dimensions in Inches
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
1 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/19/11
D-11
Dimensional View
Units: Inches [mm]
D
C
Deltrol
CONTROLS
UNLESS OTHERWISE SPECIFIED
INCHES ± .015
(MILLIMETERS 0.38)
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
2 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/19/11
D-11
Force Curves
D
C
Deltrol
CONTROLS
AC Continuous Duty - 12.5 VA
AC Intermittent Duty - 39 VA
DC Continuous Duty - 8 Watts
DC Intermittent Duty - 19 Watts
AC Pulse Duty- 125 VA
Standard intermittent duty cycle at nominal voltage is 25%, with three (3) minutes maximum “ON” and nine (9) minutes minimum “OFF” in a repetitive cycle. Standard Pulse duty cycle is 10% with 100 milliseconds “ON” and 900 milliseconds “OFF”. NOTE: Approx 36 sq. in. Heat Sink Required
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
DC Pulse Duty - 80 Watts
3 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/19/11
D-11
Standard Part Numbers
D
C
Deltrol
CONTROLS
Parts No. Voltage Duty Cycle Power
53738-80 6 VAC
53738-81 12 VAC 1.9
53738-82 24 VAC 7.7
53738-84* 120 VAC 200
53738-85 240 VAC 813
53738-86 6 VAC
53738-87 12 VAC 0.86
53738-88 24 VAC 3.5
53738-90* 120 VAC 85
53738-91 240 VAC 342
53738-92 6 VAC
53738-93 12 VAC 0.43
53738-94 24 VAC 1.73
53738-96 120 VAC 45.5
53738-97 240 VAC 182
53736-80 6 VDC
53736-81* 12 VDC 18.6
53736-82* 24 VDC 73.9
53736-84 110 VDC 1550
53736-86 6 VDC
53736-87* 12 VDC 7.7
53736-88* 24 VDC 31
53736-90 110 VDC 634
53736-92 6 VDC
53736-93 12 VDC 1.9
53736-94 24 VDC 7.7
53736-96 110 VDC 151
Continuous 12.5 VA
Intermittent
Pulse 125 VA
Continuous 8 Watts
Intermittent
Pulse
39 VA
19
Watts
80
Watts
Resistance
(Ohms)
0.47
0.21
0.11
4.5
1.9
0.47
Operation
Pull 54 13 11 10 8
Pull 92 28 23 23 20
Pull 116 51 40 38 34
Pull 61 22.5 8 4 2
Pull 65 40 22 10 5
Pull 77 74 53 34 21
Typical Force (oz). 100% Voltage, 77°, Stroke @
0.000” 0.125” 0.250” 0.500” 0.750”
(*) Normally Stocked Non stocked items require a minimum order
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
4 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/19/11
D-17
C
D
Deltrol
CONTROLS
D-FRAME SOLENOID
Two position linear solenoid with D-frame construction.
Features
• Balance of cost and performance
• AC solenoids and DC solenoids available
• Encapsulated coils on most models
• UL approval on many models
Electrical Specications
Coil Voltages 6, 12, 24 120, 240 VAC | 6, 12, 24, 110 VDC
Coil Power
Coil Termination
Duty Cycle
Coil Treatment Encapsulated (tape wrapped optional)
Insulation Class Class A Rating - 105ºC (221ºF) Max. (standard)
Dielectric Strength
Mechanical Specications
Size 1.624” (L) x 0.875” (W) x 1.062” (H) (See page 2 for dimensional drawing)
Forces See page 3 for force curves
Plunger Diameter 0.3125”
Plunger Guide Material Plastic
Mounting 2X #6-32 UNC-2B Mounting Holes
Weight Plunger - 0.50 oz., Total - 4 oz
Life Expectancy 250,000 Cycles (Dependent on load conditions)
Agency Approval
9.4 VA Continuous, 23 VA Intermittent, 93 VA Pulse 6 Watts Continuous, 14.5 Watts Intermittent, 60 Watts Pulse
.187” Quick Connect Terminals (standard) Wire leads optional with tape wrapped coil
Continuous, intermittent and pulse duty available (see standard part numbers on page 4)
30 Volts and Under: 500 VRMS Over 30 Volts: 1000 VRMS plus 2X rated voltage for 1 minute
UL File No. E57982 For Continuous Duty UL File No. E74443 For Insulation Systems S105
All dimensions in Inches
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
1 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/19/11
D-17
Dimensional View
Units: Inches [mm]
C
D
UNLESS OTHERWISE SPECIFIED
Deltrol
CONTROLS
INCHES ± .015
(MILLIMETERS 0.38)
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
2 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/19/11
D-17
Force Curves
D
C
Deltrol
CONTROLS
AC Continuous Duty - 9.4 VA
AC Intermittent Duty - 23 VA
DC Continuous Duty - 6 Watts
DC Intermittent Duty - 14.5 Watts
AC Pulse Duty- 93 VA
Standard intermittent duty cycle at nominal voltage is 25%, with three (3) minutes maximum “ON” and nine (9) minutes minimum “OFF” in a repetitive cycle. Standard Pulse duty cycle is 10% with 100 milliseconds “ON” and 900 milliseconds “OFF”. NOTE: Approx 36 sq. in. Heat Sink Required
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
DC Pulse Duty - 60 Watts
3 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/19/11
D-17
Standard Part Numbers
D
C
Deltrol
CONTROLS
Parts No. Voltage Duty Cycle Power
53701-80 6 VAC
53701-81 12 VAC 2.95
53701-82 24 VAC 12.1
53701-84 120 VAC 303
53701-85 240 VAC 1220
53701-86 6 VAC
53701-87 12 VAC 1.62
53701-88 24 VAC 6.5
53701-90 120 VAC 169
53701-91 240 VAC 673
53701-92 6 VAC
53701-93 12 VAC 0.733
53701-94 24 VAC 2.95
53701-96 120 VAC 74.2
53701-97 240 VAC 303
53700-80 6 VDC
53700-81 12 VDC 24.4
53700-82 24 VDC 98.4
53700-84 110 VDC 1990
53700-86 6 VDC
53700-87 12 VDC 9.9
53700-88 24 VDC 39.2
53700-90 110 VDC 839
53700-92 6 VDC
53700-93 12 VDC 2.45
53700-94 24 VDC 9.9
53700-96 110 VDC 211
Continuous 9.4 VA
Intermittent 23 VA
Pulse 93 VA
Continuous
Intermittent
Pulse
Watts
14.5
Watts
60
Watts
Resistance
(Ohms)
0.733
0.41
0.183
6.1
6
2.45
.60
Operation
Pull 58 12 9 7 3
Pull 81 20 16 12 7
Pull 113 46 36 27 14
Pull 53 12 5 1.8 0.8
Pull 63 27 12 4.5 2
Pull 76 57 38 19 7
Typical Force (oz). 100% Voltage, 77°, Stroke @
0.000” 0.125” 0.250” 0.500” 0.750”
(*) Normally Stocked Non stocked items require a minimum order
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
4 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/19/11
D-22
C
D
Deltrol
CONTROLS
D-FRAME SOLENOID
Two position linear solenoid with D-frame construction.
Features
• Balance of cost and performance
• AC solenoids and DC solenoids available
• Encapsulated coils on most models
• UL approval on many models
Electrical Specications
Coil Voltages 6, 12, 24, 120, 240 VAC | 6, 12, 24, 110 VDC
Coil Power
Coil Termination
Duty Cycle Continuous, intermittent and pulse duty available (see standard part numbers on page 4)
Coil Treatment Encapsulated (tape wrapped optional)
Insulation Class Class A Rating - 105ºC (221ºF) Max. (standard)
Dielectric Strength
Mechanical Specications
Size 1.130” (L) x 0.750” (W) x 0.750” (H) (See page 2 for dimensional drawing)
Forces See force curves on page 3
Plunger Diameter 0.250”
Plunger Guide Material Plastic
Mounting 2X #4-40 UNC-2B Mounting Holes
Weight Plunger - 0.25 oz., Total - 1.50 oz.
Life Expectancy 250,000 Cycles (Dependent on load conditions)
Agency Approval
6.5 VA Continuous, 8.5 VA Intermittent, 60 VA Pulse
4.2 Watts Continuous, 9.6 Watts Intermittent, 40 Watts Pulse
.110” quick connect terminals (standard) Wire leads optional with tape wrapped coil
30 Volts and Under: 500 VRMS Over 30 Volts: 1000 VRMS plus 2X rated voltage for 1 minute
UL File No. E57982 For Continuous Duty UL File No. E74443 For Insulation Systems S105
All dimensions in Inches
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
1 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/19/11
D-22
Dimensional View
Units: Inches [mm]
C
D
UNLESS OTHERWISE SPECIFIED
Deltrol
CONTROLS
INCHES ± .015
(MILLIMETERS 0.38)
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
2 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/19/11
D-22
Force Curves
AC Continuous Duty - 6.5 VA DC Continuous Duty - 4.2 Watts
D
C
Deltrol
CONTROLS
AC Intermittent Duty - 8.5 VA
AC Pulse Duty- 60 VA
DC Intermittent Duty - 9.6 Watts
DC Pulse Duty - 40 Watts
Standard intermittent duty cycle at nominal voltage is 25%, with three (3) minutes maximum “ON” and nine (9) minutes minimum “OFF” in a repetitive cycle. Standard Pulse duty cycle is 10% with 100 milliseconds “ON” and 900 milliseconds “OFF”. NOTE: Approx 36 sq. in. Heat Sink Required
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
3 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/19/11
D-22
Standard Part Numbers
D
C
Deltrol
CONTROLS
Parts No. Voltage Duty Cycle Power
53724-80 6 VAC
53724-81 12 VAC 10.9
53724-82 24 VAC 43.4
53724-84 120 VAC 1090
53724-85 240 VAC 4300
53724-86 6 VAC
53724-87 12 VAC 7.0
53724-88 24 VAC 27.4
53724-90 120 VAC 724
53724-91 240 VAC 2880
53724-92 6 VAC
53724-93 12 VAC 1.7
53724-94 24 VAC 27.4
53724-96 120 VAC 173
53724-97 240 VAC 724
53723-80 6 VDC
53723-81* 12 VDC 35.0
53723-82* 24 VDC 141
53723-84 110 VDC 2880
53723-86 6 VDC
53723-87 12 VDC 14.8
53723-88 24 VDC 60
53723-90 110 VDC 1274
53723-92 6 VDC
53723-93 12 VDC 3.8
53723-94 24 VDC 14.8
53723-96 110 VDC 302
Continuous 6.5 VA
Intermittent 8.5 VA
Pulse 60 VA
Continuous
Intermittent
Pulse
4.2
Watts
9.6
Watts
40
Watts
Resistance
(Ohms)
2.75
1.7
0.420
8.7
3.8
0.91
Operation
Pull 31 3.5 2.4 1 0
Pull 53 5.2 3.3 1.5 0
Pull 73 19 14 7 0
Pull 30 4 1.8 0 0
Pull 38 10 4 0 0
Pull 49 27 15 0 0
Typical Force (oz). 100% Voltage, 77°, Stroke @
0.000” 0.125” 0.250” 0.500” 0.750”
(*) Normally Stocked Non stocked items require a minimum order
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
4 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/19/11
D-28
C
D
Deltrol
CONTROLS
D-FRAME SOLENOID
Two position linear solenoid with D-frame construction.
Features
• Balance of cost and performance
• AC solenoids and DC solenoids available
• Encapsulated coils on most models
• UL approval on many models
Electrical Specications
Coil Voltages 6, 12, 24, 120, 240 VAC | 6, 12, 24, 110 VDC
Coil Power
Coil Termination
Duty Cycle Continuous, intermittent and pulse duty available (see standard part numbers on page 4)
Coil Treatment Encapsulated (tape wrapped optional)
Insulation Class
Dielectric Strength
Mechanical Specications
Size 1.125” (H) x 0.938” (W) x 1.188” (H) (See page 2 for dimensional drawing)
Forces See force curves on page 3
Plunger Diameter 0.3125”
Plunger Guide Material Plastic
Mounting 2X #6-32 UNC-2B Mounting Holes
Weight Plunger - 0.48 oz., Total - 3.13 oz.
Life Expectancy 250,000 Cycles (Dependent on load conditions)
Agency Approval
8 VA Continuous, 21 VA Intermittent, 80 VA Pulse
5.5 Watts Continuous, 11.5 Watts Intermittent, 55 Watts Pulse
.187” quick connect terminals (standard) Wire leads optional with tape wrapped coil
Class A Rating - 105ºC (221ºF) Max. (standard) Class F Rating - 155ºC (311ºF) Max. (optional)
30 Volts and Under: 500 VRMS Over 30 Volts: 1000 VRMS plus 2X rated voltage for 1 minute
UL File No. E57982 For Continuous Duty UL File No. E74443 For Insulation Systems S105, S130, S130D, S130D1, S155D
All dimensions in Inches
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
1 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/19/11
D-28
Dimensional View
Units: Inches [mm]
C
D
UNLESS OTHERWISE SPECIFIED
Deltrol
CONTROLS
INCHES ± .015
(MILLIMETERS 0.38)
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
2 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/19/11
D-28
Force Curves
AC Continuous Duty - 8 VA DC Continuous Duty - 5.5 Watts
D
C
Deltrol
CONTROLS
AC Intermittent Duty - 21 VA
AC Pulse Duty- 80 VA
DC Intermittent Duty - 11.5 Watts
DC Pulse Duty - 55 Watts
Standard intermittent duty cycle at nominal voltage is 25%, with three (3) minutes maximum “ON” and nine (9) minutes minimum “OFF” in a repetitive cycle. Standard Pulse duty cycle is 10% with 100 milliseconds “ON” and 900 milliseconds “OFF”. NOTE: Approx 36 sq. in. Heat Sink Required
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
3 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/19/11
D-28
Standard Part Numbers
D
C
Deltrol
CONTROLS
Parts No. Voltage Duty Cycle Power
53706-80 6 VAC
53706-81 12 VAC 4.05
53706-82 24 VAC 16.2
53706-84* 120 VAC 420
53706-85 240 VAC 1700
53706-86 6 VAC
53706-87 12 VAC 2.13
53706-88 24 VAC 8.9
53706-90* 120 VAC 220
53706-91 240 VAC 890
53706-92 6 VAC
53706-93 12 VAC .90
53706-94 24 VAC 3.7
53706-96 120 VAC 94.4
53706-97 240 VAC 381
53708-80 6 VDC
53708-81* 12 VDC 27.1
53708-82* 24 VDC 108
53708-84 110 VDC 2250
53708-86 6 VDC
53708-87* 12 VDC 12.7
53708-88* 24 VDC 51
53708-90 110 VDC 1040
53708-92 6 VDC
53708-93 12 VDC 2.7
53708-94 24 VDC 11
53708-96 110 VDC 220
Continuous 8 VA
Intermittent 21 VA
Pulse 80 VA
Continuous
Intermittent
Pulse
5.5
Watts
11.5
Watts
55
Watts
Resistance
(Ohms)
1.00
0.54
.22
6.6
3.2
0.67
Operation
Pull 54 13 11 11 8
Pull 92 28 23 23 20
Pull 116 51 40 38 35
Pull 61 22 8 4 2.5
Pull 65 38 22 10 6
Pull 77 75 54 34 21
Typical Force (oz). 100% Voltage, 77°, Stroke @
0.000” 0.125” 0.250” 0.500” 0.750”
(*) Normally Stocked Non stocked items require a minimum order
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
4 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/19/11
D-30
C
D
Deltrol
CONTROLS
D-FRAME SOLENOID
Two position linear solenoid with D-frame construction.
Features
• Balance of cost and performance
• AC solenoids and DC solenoids available
• Encapsulated coils on most models
• UL approval on many models
Electrical Specications
Coil Voltages 6, 12, 24, 120, 240 VAC | 6, 12, 24, 110 VDC
Coil Power
Coil Termination
Duty Cycle Continuous, intermittent and pulse duty available (see standard part numbers on page 4)
Coil Treatment Encapsulated (tape wrapped optional)
Insulation Class
Dielectric Strength
Mechanical Specications
Size 2.015” (L) x 1.000” (W) x 1.218” (H) (See page 2 for dimensional drawing)
Forces See force curves on page 3
Plunger Diameter 0.4375”
Plunger Guide Material Plastic
Mounting 2X #8-32 UNC-2B Mounting Holes
Weight Plunger - 1.06 oz., Total - 7 oz.
Life Expectancy 250,000 Cycles (Dependent on load conditions)
Agency Approval
13 VA Continuous, 37 VA Intermittent, 120 VA Pulse
8.5 Watts Continuous, 21 Watts Intermittent, 85 Watts Pulse
.187” quick connect terminals (standard) Wire leads optional with tape wrapped coil
Class A Rating - 105ºC (221ºF) Max. (standard) Class F Rating - 155ºC (311ºF) Max. (optional)
30 Volts and Under: 500 VRMS Over 30 Volts: 1000 VRMS plus 2X rated voltage for 1 minute
UL File No. E57982 For Continuous Duty UL File No. E74443 For Insulation Systems S105, S130, S130D, S130D1, S155D
All dimensions in Inches
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
1 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/18/11
D-30
Dimensional View
Units: Inches [mm]
D
C
Deltrol
CONTROLS
UNLESS OTHERWISE SPECIFIED
INCHES ± .015
(MILLIMETERS 0.38)
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
2 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/18/11
D-30
Force Curves
AC Continuous Duty - 13 VA DC Continuous Duty - 8.5 Watts
D
C
Deltrol
CONTROLS
AC Intermittent Duty - 37 VA
AC Pulse Duty- 120 VA
DC Intermittent Duty - 21 Watts
DC Pulse Duty - 85 Watts
Standard intermittent duty cycle at nominal voltage is 25%, with three (3) minutes maximum “ON” and nine (9) minutes minimum “OFF” in a repetitive cycle. Standard Pulse duty cycle is 10% with 100 milliseconds “ON” and 900 milliseconds “OFF”. NOTE: Approx 36 sq. in. Heat Sink Required
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
3 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/18/11
D-30
Standard Part Numbers
D
C
Deltrol
CONTROLS
Parts No. Voltage Duty Cycle Power
53748-80 6 VAC
53748-81 12 VAC 1.65
53748-82 24 VAC 6.71
53748-84 120 VAC 172
53748-85 240 VAC 700
53748-87 12 VAC
53748-88 24 VAC 3.78
53748-90 120 VAC 86.2
53748-91 240 VAC 353
53748-93 12 VAC
53748-94 24 VAC 1.73
53748-96 120 VAC 45.5
53748-97 240 VAC 182
53749-80 6 VDC
53749-81* 12 VDC 17.7
53749-82* 24 VDC 69.8
53749-84 110 VDC 1470
53749-86 6 VDC
53749-87* 12 VDC 6.71
53749-88* 24 VDC 26.8
53749-90 110 VDC 538
53749-92 6 VDC
53749-93 12 VDC 1.65
53749-94 24 VDC 6.71
53749-96 110 VDC 148
Continuous 13 VA
Intermittent 37 VA
Pulse 120 VA
Continuous
Intermittent
Pulse
8.5
Watts
21
Watts
85
Watts
Resistance
(Ohms)
0.41
0.871
0.43
4.27
1.65
0.41
Operation
Pull 65 16.5 13 11 0
Pull 108 29 21 17 0
Pull 176 55 40 33 0
Pull 110 28 15 6 0
Pull 133 58 40 16 0
Pull 185 115 97 55 23
Typical Force (oz). 100% Voltage, 77°, Stroke @
0.000” 0.125” 0.250” 0.500” 0.750”
(*) Normally Stocked Non stocked items require a minimum order
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
4 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/18/11
D-50
C
D
Deltrol
CONTROLS
D-FRAME SOLENOID
Two position linear solenoid with D-frame construction.
Features
• Balance of cost and performance
• AC solenoids and DC solenoids available
• UL approval on many models
Electrical Specications
Coil Voltages 12, 24, 120, 240 VAC, | 6, 12, 24, 110 VDC
Coil Power
Coil Termination Wire leads (standard)
Duty Cycle Continuous, intermittent and pulse duty available (see standard part numbers on page 4)
Coil Treatment Tape Wrapped
Insulation Class
Dielectric Strength
Mechanical Specications
Size 1.625” (L) x 1.562” (W) x 1.828” (H) (See page 2 for dimensional drawing)
Forces See force curves on page 3
Plunger Diameter 0.500”
Plunger Guide Material Plastic
Mounting 4X #8-32 UNC-2B Mounting Holes
Weight Plunger - 1.27 oz., Total - 12 oz.
Life Expectancy 250,000 Cycles (Dependent on load conditions)
Agency Approval
14 VAC Continuous, 53 VA Intermittent, 140 VA Pulse 10 Watts Continuous, 25 Watts Intermittent, 100 Watts Pulse
Class A Rating - 105ºC (221ºF) Max. (standard) Class B Rating - 130ºC (266ºF) Max. (optional)
30 Volts and Under: 500 VRMS Over 30 Volts: 1000 VRMS plus 2X rated voltage for 1 minute
UL File No. E57982 For Continuous Duty UL File No. E74443 For Insulation Systems S105, S130
All dimensions in Inches
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
1 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/08/11
D-50
Dimensional View
Units: Inches [mm]
D
C
Deltrol
CONTROLS
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
2 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
UNLESS OTHERWISE SPECIFIED
INCHES ± .015
(MILLIMETERS 0.38)
Rev 07/08/11
D-50
Force Curves
AC Continuous Duty - 14 VA DC Continuous Duty - 10 Watts
D
C
Deltrol
CONTROLS
AC Intermittent Duty - 53 VA
AC Pulse Duty- 140 VA
DC Intermittent Duty - 25 Watts
DC Pulse Duty - 100 Watts
Standard intermittent duty cycle at nominal voltage is 25%, with three (3) minutes maximum “ON” and nine (9) minutes minimum “OFF” in a repetitive cycle. Standard Pulse duty cycle is 10% with 100 milliseconds “ON” and 900 milliseconds “OFF”. NOTE: Approx 36 sq. in. Heat Sink Required
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
3 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/08/11
D-50
Standard Part Numbers
D
C
Deltrol
CONTROLS
Parts No. Voltage Duty Cycle Power
51053-81 12 VAC
51053-83 24 VAC 3.8
51053-94 120 VAC 97.4
51053-97 240 VAC 392
51014-83 24 VAC
50014-97 240 VAC 162
53699-83 24 VAC
53699-97 240 VAC 72.7
51051-80 6 VDC
51051-81 12 VDC 14.5
51051-83 24 VDC 58.2
51051-93 110 VDC 1210
50029-80 6 VDC
50029-81 12 VDC 5.7
50029-83 24 VDC 23
50029-93 110 VDC 486
53744-80 6 VDC
53744-81 12 VDC 1.42
53744-82 24 VDC 5.7
53744-84 110 VDC 121
Continuous 14 VA
Intermittent 53 VA
Pulse 140 VA
Continuous
Intermittent
Pulse
10
Watts
25
Watts
100
Watts
Resistance
(Ohms)
.95
1.55
0.70
3.77
1.42
0.35
Operation
Pull 84 24 21 19 10
Pull 151 52 46 40 2451014-94 120 VAC 40.7
Pull 227 10 994 90 5453699-94 120 VAC 18.1
Pull 158 60 25 8 4
Pull 183 128 65 21 9
Pull 226 225 180 82 35
Typical Force (oz). 100% Voltage, 77°, Stroke @
0.000” 0.125” 0.250” 0.500” 0.750”
(*) Normally Stocked Non stocked items require a minimum order
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
4 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/08/11
D-70
C
D
Deltrol
CONTROLS
D-FRAME SOLENOID
Two position linear solenoid with D-frame construction.
Features
• Balance of cost and performance
• AC solenoids and DC solenoids available
• UL approval on many models
Electrical Specications
Coil Voltages 6, 12, 24, 110 VDC
Coil Power 13 Watts Continuous, 48 Watts Intermittent, 130 Watts Pulse
Coil Termination Wire leads (standard)
Duty Cycle
Coil Treatment Tape wrapped
Insulation Class
Dielectric Strength
Mechanical Specications
Size 2.625” (L) x 1.562” (W) x 1.828” (H) (See page 2 for dimensional drawing)
Forces See force curves on page 3
Plunger Diameter 0.500”
Plunger Guide Material Plastic
Mounting 6X #8-32 UNC-2B Mounting Holes
Weight Plunger - 1.92 oz., Total - 19 oz.
Life Expectancy 250,000 Cycles (Dependent on load conditions)
Agency Approval
Continuous, intermittent and pulse duty available (see standard part numbers on page 4)
Class A Rating - 105ºC (221ºF) Max. (standard) Class B Rating - 130ºC (266ºF) Max. (optional)
30 Volts and Under: 500 VRMS Over 30 Volts: 1000 VRMS plus 2X rated voltage for 1 minute
UL File No. E57982 For Continuous Duty UL File No. E74443 For Insulation Systems S105, S130
All dimensions in Inches
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
1 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/08/11
D-70
Dimensional View
Units: Inches [mm]
D
C
Deltrol
CONTROLS
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
2 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
UNLESS OTHERWISE SPECIFIED
INCHES ± .015
(MILLIMETERS 0.38)
Rev 07/08/11
D-70
Force Curves
DC Continuous Duty - 13 Watts
DC Intermittent Duty - 48 Watts
D
C
Deltrol
CONTROLS
Standard intermittent duty cycle at nominal voltage is 25%, with three (3) minutes maximum “ON” and nine (9) minutes
minimum “OFF” in a repetitive cycle. Standard Pulse duty cycle is 10% with 100 milliseconds “ON” and 900 milliseconds “OFF”.
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
DC Pulse Duty - 130 Watts
NOTE: Approx 36 sq. in. Heat Sink Required
3 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/08/11
D-70
Standard Part Numbers
D
C
Deltrol
CONTROLS
Parts No. Voltage Duty Cycle Power
50046-80 6 VDC
50046-81* 12 VDC 11
50046-83* 24 VDC 44.3
50046-93* 110 VDC 940
50031-80 6 VDC
50031-81* 12 VDC 3.0
50031-83* 24 VDC 12.0
50031-93* 110 VDC 254
53714-81 12 VDC
53714-93 110 VDC 92
(*) Normally Stocked Non stocked items require a minimum order
Continuous
Intermittent
Pulse
13
Watts
48
Watts
130
Watts
Resistance
(Ohms)
2.75
0.75
1.1
Operation
Pull 150 79 62 30 15
Pull 211 130 112 82 50
Pull 247 180 165 135 10053714-83 24 VDC 4.5
Typical Force (oz). 100% Voltage, 77° F, Stroke @
0.000” 0.125” 0.250” 0.500” 0.750”
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
4 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/08/11
D-90
C
D
Deltrol
CONTROLS
D-FRAME SOLENOID
Two position linear solenoid with D-frame construction.
Features
• Balance of cost and performance
• DC solenoids available
• UL approval on many models
Electrical Specications
Coil Voltages 6, 12, 24, 110 VDC
Coil Power 23 Watts Continuous, 58 Watts Intermittent, 230 Watts Pulse
Coil Termination Wire leads (standard)
Duty Cycle Continuous, intermittent and pulse duty available (see standard part numbers on page 4)
Coil Treatment Tape Wrapped
Insulation Class
Dielectric Strength
Mechanical Specications
Size 3.540” (L) x 1.750” (W) x 1.940” (H) (See page 2 for dimensional drawing)
Forces See force curves on page 3
Plunger Diameter 0.625”
Plunger Guide Material Plastic
Mounting 12X #8-32 UNC-2B
Weight Plunger - 4.3 oz., Total - 34 oz.
Life Expectancy 250,000 Cycles (Dependent on load conditions)
Agency Approval
Class A Rating - 105ºC (221ºF) Max. (standard) Class B Rating - 130ºC (266ºF) Max. (optional)
30 Volts and Under: 500 VRMS Over 30 Volts: 1000 VRMS plus 2X rated voltage for 1 minute
UL File No. E57982 For Continuous Duty UL File No. E74443 For Insulation Systems S105, S130
All dimensions in Inches
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
1 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/19/11
D-90
Dimensional View
Units: Inches [mm]
D
C
Deltrol
CONTROLS
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
2 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
UNLESS OTHERWISE SPECIFIED
INCHES ± .015
(MILLIMETERS 0.38)
Rev 07/19/11
D-90
Force Curves
DC Continuous Duty - 23 Watts
DC Intermittent Duty - 58 Watts
D
C
Deltrol
CONTROLS
Standard intermittent duty cycle at nominal voltage is 25%, with three (3) minutes maximum “ON” and nine (9) minutes minimum “OFF” in a repetitive cycle. Standard Pulse duty cycle is 10% with 100 milliseconds “ON” and 900 milliseconds “OFF”. NOTE: Approx 100 sq. in. Heat Sink Required NOTE: Cold Force @ 25° C (77°F) Coil Temperature Hot Force @ 110°C (230°F) Coil Temperature
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
DC Pulse Duty - 230 Watts
3 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/19/11
D-90
Standard Part Numbers
D
C
Deltrol
CONTROLS
Parts No. Voltage Duty Cycle Power
53654-80 6 VDC
53654-81 12 VDC 6.3
53654-83 24 VDC 25
53654-93 110 VDC 506
53655-81 12 VDC
53655-93 110 VDC 204
53656-81 12 VDC
53656-96 110 VDC 51
(*) Normally Stocked Non stocked items require a minimum order
Continuous
Intermittent
Pulse
23
Watts
58
Watts
230
Watts
Resistance
(Ohms)
1.58
2.2
0.6
Operation
Pull 150 115 108 80 50
Pull 202 162 158 133 10053655-83 24 VDC 10.2
Pull 303 280 275 235 20553656-83 24 VDC 2.2
Typical Force (oz). 100% Voltage, 77° F, Stroke @
0.000” 0.125” 0.250” 0.500” 0.750”
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
4 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/19/11
PS-75
C
D
Deltrol
CONTROLS
D-FRAME SOLENOID
Two position linear solenoid with D-frame construction.
Features
• Balance of cost and performance
• DC solenoids available
Electrical Specications
Coil Voltages 6, 12, 24, 28, 32, 36, 48, 90, 115 VDC
Coil Power 150 Watts Continuous
Coil Termination Wire leads (standard)
Duty Cycle Continuous
Coil Treatment Tape Wrapped
Insulation Class Class A Rating - 105ºC (221ºF) Max. (standard)
Dielectric Strength
Mechanical Specications
Size 2.625” (L) x 1.562” (W) x 1.828” (H) (See page 2 for dimensional drawing)
Forces See force curves on page 2
Plunger Diameter 0.500”
Plunger Guide Material Brass
Mounting 6X #8-32 UNC-2B Mount Holes
Weight Plunger - 1.91 oz., Total - 19 oz.
Life Expectancy 250,000 Cycles (Dependent on load conditions)
Agency Approval
30 Volts and Under: 500 VRMS Over 30 Volts: 1000 VRMS plus 2X rated voltage for 1 minute
All dimensions in Inches
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
1 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/20/11
PS-75
Dimensional View
Units: Inches [mm]
D
C
Deltrol
CONTROLS
UNLESS OTHERWISE SPECIFIED
INCHES ± .015
(MILLIMETERS 0.38)
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
2 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/20/11
PS-75
Force Curve
D
C
Deltrol
CONTROLS
Schematic
(With plunger at 0 stroke)
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
3 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/20/11
PS-75
Standard Part Numbers
D
C
Deltrol
CONTROLS
Parts No. Voltage Duty Cycle Power
51073-80 6 VDC
51073-81* 12 VDC
51073-83* 24 VDC
51073-85 28 VDC
51073-87 32 VDC
51073-88 36 VDC
51073-89 48 VDC
51073-90 90 VDC
51073-93 115 VDC
Continuous
150
Watt
Resistance
(Ohms)
0.24 Pull
2.75 Hold
0.96 Pull 11 Hold
3.84 Pull
44.2 Hold
5.2 Pull
60 Hold
6.8 Pull
78.6 Hold
8.6 Pull
99 Hold
15.4 Pull
176.6 Hold
54 Pull
620 Hold
88 Pull
1020 Hold
Operation
Pull 200 250 205 125 80
Typical Force (oz). 100% Voltage, 77° F, Stroke @
0.000” 0.125” 0.250” 0.500” 0.750”
(*) Normally Stocked Non stocked items require a minimum order
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
4 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/20/11
MED 12x1.500
C
D
Deltrol
CONTROLS
TUBULAR FRAME SOLENOID
Two position linear solenoid with tubular construction.
Features
• High performance construction
• DC solenoids applications only
• Standard push and pull versions available
• UL approval on many models
Electrical Specications
Coil Voltages 6, 12, 24, 115 VDC
Coil Power 6 Watts Continuous, 15 Watts Intermittent, 58 Watts Pulse
Coil Termination Wire leads 24 AWG (standard)
Duty Cycle Continuous, intermittent, pulse (see standard part numbers on page 4)
Coil Treatment Tape wrapped
Insulation Class Class A Rating - 105ºC (221ºF) Max.
Dielectric Strength
Mechanical Specications
Size 1.500” (L) x Ø0.750” (D)
Forces See force curves on page 3
Plunger Diameter Ø.3125”
Plunger Guide Material Plastic
Mounting 0.750” Hex Nut
Weight Plunger - 0.75 oz., Total - 2.56 oz.
Life Expectancy 250,000 Cycles (Dependent on load conditions)
Agency Approvals
30 Volts and Under: 500 VRMS Over 30 Volts: 1000 VRMS plus 2X rated voltage for 1 minute
UL File No. E57982 For Continuous Duty UL File No. E74443 For Insulation Systems
S105
All dimensions in Inches
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
1 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
MED 12x1.500
Dimensional View
Units: Inches [mm]
D
C
Deltrol
CONTROLS
UNLESS OTHERWISE SPECIFIED
INCHES ± .015
(MILLIMETERS 0.38)
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
2 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
MED 12x1.500
Force Curves
DC Continuous Duty - 6 Watts
DC Intermittent Duty - 15 Watts
D
C
Deltrol
CONTROLS
DC Pulse Duty - 58 Watts
Standard intermittent duty cycle at nominal voltage is one (1) minute “ON” and
three (3) minutes “OFF”. Standard pulse duty cycle is 100 milliseconds “ON”
and 900 milliseconds “OFF”.
Note:
Cold Force @ 25°C (77°F) Cold Temperature
Hot Force @ 130°C (266°F) Coil Temperature
Approx. 16 sq. in. Heat Sink Required
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
3 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
MED 12x1.500
Standard Part Numbers
D
C
Deltrol
CONTROLS
6
Resistance
(Ohms)
6.2 Pull
2.5 Pull
0.62 Pull
Operation
Parts No. Voltage Duty Cycle Power
53751-80 6 VDC
53761-80 6 VDC 6.2 Push
53751-81* 12 VDC 25 Pull
53761-81* 12 VDC 25 Push
53751-82* 24 VDC 100 Pull
53761-82* 24 VDC 100 Push
53751-84 115 VDC 2500 Pull
53761-84 115 VDC 2500 Push
53751-86 6 VDC
53761-86 6 VDC 2.5 Push
53751-87* 12 VDC 10 Pull
53761-87* 12 VDC 10 Push
53751-88* 24 VDC 40 Pull
53761-88* 24 VDC 40 Push
53751-90 115 VDC 1000 Pull
53761-90 115 VDC 1000 Push
53751-92 6 VDC
53761-92 6 VDC 0.62 Push
53751-93 12 VDC 2.5 Pull
53761-93 12 VDC 2.5 Push
53751-94 24 VDC 10 Pull
53761-94 24 VDC 10 Push
53751-96 115 VDC 250 Pull
53761-96 115 VDC 250 Push
Continuous
Intermittent
Pulse
Watts
15
Watts
58
Watts
Typical Force (oz). 100% Voltage, 77° F, Stroke @
0.000” 0.125” 0.250” 0.500” 0.750”
38 7.5 3 1.5 0
50 20 10 4 0
64 40 26 16 0
(*) Normally Stocked Non stocked items require a minimum order
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
4 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
MED 16x1.125
C
D
Deltrol
CONTROLS
TUBULAR FRAME SOLENOID
Two position linear solenoid with tubular frame construction.
Features
• High performance construction
• DC solenoids applications only
• Standard push and pull versions available
• UL approval on many models
Electrical Specications
Coil Voltages 6, 12, 24, 115 VDC
Coil Power 8 Watts Continuous, 19 Watts Intermittent, 77 Watts Pulse
Coil Termination Wire leads 24 AWG (standard)
Duty Cycle Continuous, intermittent and pulse (See standard part numbers on page 4)
Coil Treatment Tape Wrapped
Insulation Class Class A Rating - 105ºC (221ºF) Max.
Dielectric Strength
Mechanical Specications
Size 1.125” (L) x Ø1.000” (D)
Forces See force curves on page 3
Plunger Diameter Ø.4375”
Plunger Guide Material Plastic
Mounting 0.875” Hex Nut
Weight Plunger - 1.05 oz, Total - 4.375 oz
Life Expectancy 250,000 Cycles (Dependent on load conditions)
Agency Approvals
30 Volts and Under: 500 VRMS Over 30 Volts: 1000 VRMS plus 2X rated voltage for 1 minute
UL File No. E57982 For Continuous Duty UL File No. E74443 For Insulation Systems S105
All dimensions in Inches
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
1 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
MED 16x1.125
Dimensional View
Units: Inches [mm]
D
C
Deltrol
CONTROLS
UNLESS OTHERWISE SPECIFIED
INCHES ± .015
(MILLIMETERS 0.38)
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
2 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
MED 16x1.125
Force Curves
DC Continuous Duty - 8 Watts
DC Intermittent Duty - 19 Watts
D
C
Deltrol
CONTROLS
DC Pulse Duty - 77 Watts
Standard intermittent duty cycle at nominal voltage is one (1) minute “ON” and
three (3) minutes “OFF”. Standard pulse duty cycle is 100 milliseconds “ON”
and 900 milliseconds “OFF”.
Note:
Cold Force @ 25°C (77°F) Cold Temperature
Hot Force @ 130°C (266°F) Coil Temperature
Approx. 36 sq. in. Heat Sink Required
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
3 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
MED 16x1.125
Standard Part Numbers
D
C
Deltrol
CONTROLS
8
Resistance
(Ohms)
4.7 Pull
1.9 Pull
0.47 Pull
Operation
Parts No. Voltage Duty Cycle Power
53754-80 6 VDC
53759-80 6 VDC 4.7 Push
53754-81* 12 VDC 19 Pull
53759-81 12 VDC 19 Push
53754-82* 24 VDC 75 Pull
53759-82 24 VDC 75 Push
53754-84 115 VDC 1900 Pull
53759-84 115 VDC 1900 Push
53754-86 6 VDC
53759-86 6 VDC 1.9 Push
53754-87* 12 VDC 7.5 Pull
53759-87 12 VDC 7.5 Push
53754-88* 24 VDC 30 Pull
53759-88 24 VDC 30 Push
53754-90 115 VDC 750 Pull
53759-90 115 VDC 750 Push
53754-92 6 VDC
53759-92 6 VDC 0.47 Push
53754-93 12 VDC 1.9 Pull
53759-93 12 VDC 1.9 Push
53754-94 24 VDC 7.5 Pull
53759-94 24 VDC 7.5 Push
53754-96 115 VDC 190 Pull
53759-96 115 VDC 190 Push
Continuous
Intermittent
Pulse
Watts
19
Watts
77
Watts
Typical Force (oz). 100% Voltage, 77°, Stroke @
0.000” 0.125” 0.250” 0.500” 0.750”
94 13 4 0 0
126 30 10 0 0
180 93 50 0 0
(*) Normally Stocked Non stocked items require a minimum order
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
4 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
MED 16x2.000
C
D
Deltrol
CONTROLS
TUBULAR FRAME SOLENOID
Two position linear solenoid with tubular construction.
Features
• High performance construction
• DC solenoids applications only
• Standard push and pull versions available
• UL approval on many models
Electrical Specications
Coil Voltages 6, 12, 24, 115 VDC
Coil Power 10 Watts Continuous, 24 Watts Intermittent, 96 Watts Pulse
Coil Termination Wire leads 24 AWG (standard)
Duty Cycle Continuous, intermittent and pulse (see standard part numbers on page 4)
Coil Treatment Tape wrapped
Insulation Class Class A Rating - 105ºC (221ºF) Max.
Dielectric Strength
Mechanical Specications
Size 2.000” (L) x Ø1.000” (D)
Forces See force curves on page 3
Plunger Diameter Ø.4375”
Plunger Guide Material Plastic
Mounting 0.875” Hex Nut
Weight Plunger - 1.53 oz., Total - 6.5 oz.
Life Expectancy 250,000 Cycles (Dependent on load conditions)
Agency Approvals
30 Volts and Under: 500 VRMS Over 30 Volts: 1000 VRMS plus 2X rated voltage for 1 minute
UL File No. E57982 For Continuous Duty UL File No. E74443 For Insulation Systems S105
All dimensions in Inches
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
1 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
MED 16x2.000
Dimensional View
Units: Inches [mm]
D
C
Deltrol
CONTROLS
UNLESS OTHERWISE SPECIFIED
INCHES ± .015
(MILLIMETERS 0.38)
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
2 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
MED 16x2.000
Force Curves
DC Continuous Duty - 10 Watts
DC Intermittent Duty - 24 Watts
D
C
Deltrol
CONTROLS
Standard intermittent duty cycle at nominal voltage is one (1) minute “ON” and
three (3) minutes “OFF”. Standard pulse duty cycle is 100 milliseconds “ON”
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
DC Pulse Duty - 96 Watts
and 900 milliseconds “OFF”.
Note:
Cold Force @ 25°C (77°F) Cold Temperature
Hot Force @ 130°C (266°F) Coil Temperature
Approx. 36 sq. in. Heat Sink Required
3 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
MED 16x2.000
Standard Part Numbers
D
C
Deltrol
CONTROLS
Parts No. Voltage Duty Cycle Power
53753-80 6 VDC
53757-80 6 VDC 3.8 Push
53753-81* 12 VDC 15 Pull
53757-81* 12 VDC 15 Push
53753-82* 24 VDC 60 Pull
53757-82* 24 VDC 60 Push
53753-84 115 VDC 1500 Pull
53757-84 115 VDC 1500 Push
53753-86 6 VDC
53757-86 6 VDC 1.5 Push
53753-87* 12 VDC 6 Pull
53757-87* 12 VDC 6 Push
53753-88* 24 VDC 24 Pull
53757-88* 24 VDC 24 Push
53753-90 115 VDC 600 Pull
53757-90 115 VDC 600 Push
53753-92 6 VDC
53757-92 6 VDC 0.37 Push
53753-93 12 VDC 1.5 Pull
53757-93 12 VDC 1.5 Push
53753-94 24 VDC 6 Pull
53757-94 24 VDC 6 Push
53753-96 115 VDC 150 Pull
53757-96 115 VDC 150 Push
Continuous
Intermittent
Pulse
10
Watts
24
Watts
96
Watts
Resistance
(Ohms)
3.8 Pull
1.5 Pull
0.37 Pull
Operation
Typical Force (oz). 100% Voltage, 77°, Stroke @
0.000” 0.125” 0.250” 0.500” 0.750”
129 42 18 8 5
149 72 36 15 8
201 150 115 77 90
(*) Normally Stocked Non stocked items require a minimum order
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
4 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
MED 19x2.700
C
D
Deltrol
CONTROLS
TUBULAR FRAME SOLENOID
Two position linear solenoid with tubular frame construction.
Features
• High performance construction
• DC solenoids applications only
• Standard pull versions available
• UL approval on many models
Electrical Specications
Coil Voltages 6, 12, 24, 115 VDC
Coil Power 12 Watts Continuous, 30 Watts Intermittent, 116 Watts Pulse
Coil Termination Wire leads 20 AWG (standard)
Duty Cycle Continuous, intermittent, pulse (see standard part numbers on page 4)
Coil Treatment Tape Wrapped
Insulation Class Class F Rating - 155ºC (311ºF) Max.
Dielectric Strength
Mechanical Specications
Size 2.700” (L) x Ø1.187” (D)
Forces See force curves on page 3
Plunger Diameter Ø.4375”
Plunger Guide Material Plastic
Mounting .88” x .16” Hex Nut
Weight Plunger - 2.1 oz., Total - 10.4 oz.
Life Expectancy 250,000 Cycles (Dependent on load conditions)
Agency Approvals
30 Volts and Under: 500 VRMS Over 30 Volts: 1000 VRMS plus 2X rated voltage for 1 minute
UL File No. E74443 For Insulation Systems S155
All dimensions in Inches
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
1 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
MED 19x2.700
Dimensional View
Units: Inches [mm]
D
C
Deltrol
CONTROLS
UNLESS OTHERWISE SPECIFIED
INCHES ± .015
(MILLIMETERS 0.38)
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
2 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
MED 19x2.700
Force Curves
DC Continuous Duty - 12 Watts
DC Intermittent Duty - 30 Watts
D
C
Deltrol
CONTROLS
DC Pulse Duty - 116 Watts
Standard intermittent duty cycle at nominal voltage is one (1) minute “ON” and
three (3) minutes “OFF”. Standard pulse duty cycle is 100 milliseconds “ON”
and 900 milliseconds “OFF”.
Note:
Cold Force @ 25°C (77°F) Cold Temperature
Hot Force @ 130°C (266°F) Coil Temperature
Approx. 36 sq. in. Heat Sink Required
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
3 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
MED 19x2.700
Standard Part Numbers
D
C
Deltrol
CONTROLS
Parts No. Voltage Duty Cycle Power
53792-80 6 VDC
53792-81 12 VDC 12
53792-82 24 VDC 48
53792-84 115 VDC 1102
53792-86 6 VDC
53792-87 12 VDC 4.8
53792-88 24 VDC 19.2
53792-90 115 VDC 441
53792-92 6 VDC
53792-93 12 VDC 1.24
53792-94 24 VDC 4.97
53792-96 115 VDC 114
(*) Normally Stocked Non stocked items require a minimum order
Continuous
Intermittent
Pulse
12
Watts
30
Watts
116
Watts
Resistance
(Ohms)
3
1.2
0.31
Operation
Pull 116 40 25 16 14
Pull 133 58 35 25 22
Pull 165 100 75 56 52
Typical Force (oz). 100% Voltage, 77°, Stroke @
0.000” 0.125” 0.250” 0.500” 0.750”
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
4 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
MED 24x1.700
C
D
Deltrol
CONTROLS
TUBULAR FRAME SOLENOID
Two position linear solenoid with tubular construction.
Features
• High performance construction
• DC solenoids applications only
• Standard push and pull versions available
• UL approval on many models
Electrical Specications
Coil Voltages 6, 12, 24, 110 VDC
Coil Power 12 Watts Continuous, 33 Watts Intermittent, 120 Watts Pulse
Coil Termination Wire leads 20 AWG (standard)
Duty Cycle Continuous, intermittent, pulse (See standard part numbers on page 4)
Coil Treatment Tape Wrapped
Insulation Class Class B Rating - 130ºC (265ºF) Max.
Dielectric Strength
Mechanical Specications
Size 1.700” (L) x Ø1.500” (D)
Forces See force curves on page 3
Plunger Diameter Ø.625”
Plunger Guide Material Brass
Mounting 1.250” Hex Nut
Weight Plunger - 2.6 oz., Total - 11.1 oz.
Life Expectancy 250,000 Cycles (Dependent on load conditions)
Agency Approvals
30 Volts and Under: 500 VRMS Over 30 Volts: 1000 VRMS plus 2X rated voltage for 1 minute
UL File No. E57982 For Continuous Duty UL File No. E74443 For Insulation Systems S130
All dimensions in Inches
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
1 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
MED 24x1.700
Dimensional View
Units: Inches [mm]
D
C
Deltrol
CONTROLS
UNLESS OTHERWISE SPECIFIED
INCHES ± .015
(MILLIMETERS 0.38)
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
2 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
MED 24x1.700
Force Curves
DC Continuous Duty - 12 Watts
DC Intermittent Duty - 33 Watts
D
C
Deltrol
CONTROLS
DC Pulse Duty - 120 Watts
Standard intermittent duty cycle at nominal voltage is one (1) minute “ON” and
three (3) minutes “OFF”. Standard pulse duty cycle is 100 milliseconds “ON”
and 900 milliseconds “OFF”.
Note:
Cold Force @ 25°C (77°F) Cold Temperature
Hot Force @ 130°C (266°F) Coil Temperature
Approx. 36 sq. in. Heat Sink Required
Specications subject to change without notice
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
3 of 4
©2011 Deltrol Controls - A Division of Deltrol Corp.
Rev 07/07/11
Loading...