Delta Products DVS Series Users Manual

2013-11-07
DVS
Series Unmanaged Industrial Ethernet Switches User’s Manual
User’s Manual
Table of Contents
Chapter 1 Overview
1.1 Features..........................................................................................1-2
1.2 Package Checklist...........................................................................1-2
Chapter 2 Hardware Description
2.1 Panel Layout ...................................................................................2-2
2.2 Dimension .....................................................................................2-24
2.3 LED Indicators...............................................................................2-25
2.4 Wiring the Redundant Power Inputs..............................................2-26
2.5 Wiring the Alarm Contact...............................................................2-27
2.6 Ethernet Interface..........................................................................2-27
2.7 DIP Switch Setting.........................................................................2-28
Chapter 3 Installation
3.1 DIN-Rail Mounting...........................................................................3-2
3.2 Wall Mounting..................................................................................3-3
Chapter 4 Functional Description
4.1 Auto MDI/MDI-X Connection ...........................................................4-2
4.2 Auto-Negotiation and Speed Sensing..............................................4-2
4.3 Stored and Forward.........................................................................4-2
4.4 Addresses Capability and Learning .................................................4-2
4.5 Quality of Service and VLAN Tagging..............................................4-2
4.6 Broadcast Control............................................................................4-2
i
ii
Chapter 1 Overview
Table of Contents
1.1 Features....................................................................................................1-2
1.2 Package Checklist.....................................................................................1-2
1-1
DVS Series Industrial Ethernet Switches
FCC Interference Statement
This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits ar e designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates radio frequency signal and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
---Reorient or relocate the receiving antenna.
---Increase the separation between the equipment and receiver.
---Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
---Consult the dealer or an experienced radio/TV technician for help.
CE Declaration of Conformity
The DVS series switches are CE certificated products, they could use in any kind of the environments under CE environment specification. For keeping more safe application, we strongly suggest to use the CE-compliant industrial enclosure products.
1.1 Features
Thank you for purchasing the DVS Unmanaged Industrial Ethernet Switches. The DVS se ries switches including 5, 8, and 16-port smart switches. Except the DVS-005I00, The DVS serie s switches are equipped with the intelligent alarm function, and allow the wide range of operating temperature (-40 to 75℃). The DVS series switches are designed to support the appli cation in any rugged environment and comply with UL, CE and FCC standards.
High Performance Network Technology
10/100Bas-T(X) (RJ45), 100Base-FX (SC/ST-Type Single/Multi mode) IEEE 802.3/802.3u/802.3x Auto negotiation speed Auto MDI/MDI-X
Industrial Grade Reliability
Relay output port support power failure, port break alarm Redundant dual DC power inputs
Robust Design
DVS-005I00/ 008I00/ 005I00A/ 008I00A operating temperature range is from -10 to 60, other
DVS switches could extend operating temperature from -40 to 75℃.
IP40, high-strength aluminum case Support DIN-Rail and Wall mounting
1.2 Package Checklist
DVS switches include the following items, if there are any of these items missing or damaged,
1-2
please contact your customer service representative for assistance. Delta DVS Unma
naged Ethernet Switch
Instruction Sheet Wall mounting Plate Protective Caps for unused RJ45 ports
Chapter 1 Overview
1-3
DVS Series Industrial Ethernet Switches
MEMO
1-4
Chapter 2 Hardware Description
Table of Contents
2.1 Panel Layout .............................................................................................2-2
2.2 Dimension ...............................................................................................2-24
2.3 LED Indicators.........................................................................................2-25
2.4 Wiring the Redundant Power Inputs........................................................ 2-26
2.5 Wiring the Alarm Contact.........................................................................2-27
2.6 Ethernet Interface....................................................................................2-27
2.7 DIP Switch Setting...................................................................................2-28
2-1
DVS Series Industrial Ethernet Switches
2.1 Panel Layout
DVS-005I00
Front Panel
1
2
5
3 4
1 Power LED 4 LINK/ACT LED 2 Ethernet port 5 Series model name 3 Speed LED
2-2
Bottom panel
Chapter 2 Hardware Description
1
2
1 Terminal Block of PWR 2 Grounding screw
2-3
DVS Series Industrial Ethernet Switches
DVS-G005I00A
Front Panel
1
2
5
3
4
1 Power LED 4 LINK/ACT LED 2 Ethernet port 5 Series model name 3 Speed LED
2-4
Bottom panel
Chapter 2 Hardware Description
1
2
1 Terminal Block of PWR 2 Grounding screw
2-5
DVS Series Industrial Ethernet Switches
DVS-005W01
Front Panel
1
2
3
4 5
6
1 Event alarm DIP Switch 4 Speed LED 2 LED (ALARM / PWR1 / PWR2) 5 LINK/ACT LED 3 Ethernet port 6 Series model name
2-6
Bottom panel
Chapter 2 Hardware Description
1
2
3
4
1 Terminal block of alarm output 3 Terminal block of PWR2 2 Terminal Block of PWR1 4 Grounding screw
2-7
DVS Series Industrial Ethernet Switches
DVS-005W01-MC01 / DVS-005W01-SC01
Front Panel
1
2
3
4
5
6
7
1 Event alarm DIP Switch 5 Speed LED 2 LED (ALARM / PWR1 / PWR2 / Fiber port speed LED) 6 LINK/ACT LED 3 Fiber Ethernet port 7 Series model name 4 Ethernet port
2-8
Bottom panel
Chapter 2 Hardware Description
1
2
3
4
1 Terminal block of alarm output 3 Terminal Block of PWR2 2 Terminal Block of PWR1 4 Grounding screw
2-9
DVS Series Industrial Ethernet Switches
DVS-008I00
Front Panel
1
2
5
3
4
1 Power LED 4 LINK/ACT LED 2 Ethernet port 5 Series model name 3 Speed LED
2-10
Bottom panel
Chapter 2 Hardware Description
1
2
1 Terminal Block of PWR 2 Grounding screw
2-11
DVS Series Industrial Ethernet Switches
DVS-G008I00A
Front Panel
1
2
5
3
4
1 Power LED 4 LINK/ACT LED 2 Ethernet port 5 Series model name 3 Speed LED
2-12
Bottom panel
Chapter 2 Hardware Description
1
2
1 Terminal Block of PWR 2 Grounding screw
2-13
DVS Series Industrial Ethernet Switches
DVS-008W01
Front Panel
1 2
3
4
5
6
1 Event alarm DIP Switch 4 Speed LED 2 LED (ALARM / PWR1 / PWR2) 5 LINK/ACT LED 3 Ethernet port 6 Series model name
2-14
Bottom panel
1
2
Chapter 2 Hardware Description
3
4
1 Terminal block of alarm output 3 Terminal Block of PWR2 2 Terminal Block of PWR1 4 Grounding screw
2-15
DVS Series Industrial Ethernet Switches
DVS-008W01-MC01 / DVS-008W01-SC01
Front Panel
1 2
3
4
7
5
6
1 Event alarm DIP 2 LED (ALARM / PWR1 / PWR2 / Fiber port speed LED) 6 LINK/ACT LED 3 Fiber Ethernet port 7 Series model name 4 Ethernet port
Switch 5 Speed LE D
2-16
Bottom panel
1
2
Chapter 2 Hardware Description
3
4
1 Terminal block of alarm output 3 Terminal Block of PWR2 2 Terminal Block of PWR1 4 Grounding screw
2-17
DVS Series Industrial Ethernet Switches
DVS-008W01-MC02 / DVS-008W01-SC02
Front Panel
1 2
3
7
3
4
5
6
1 Event alarm DIP 2 LED (ALARM / PWR1 / PWR2 / Fiber port speed LED) 6 LINK/ACT LED 3 Fiber Ethernet port 7 Series model name 4 Ethernet port
Switch 5 Speed LE D
2-18
Bottom panel
1
2
Chapter 2 Hardware Description
3
4
1 Terminal block of alarm output 3 Terminal Block of PWR2 2 Terminal Block of PWR1 4 Grounding screw
2-19
DVS Series Industrial Ethernet Switches
DVS-016W01
Front Panel
1 2
3
4
5
6
1 Event alarm DIP Switch 4 Speed LED 2 LED (ALARM / PWR1 / PWR2) 5 LINK/ACT LED 3 Ethernet port 6 Series model name
2-20
Bottom panel
1
2
Chapter 2 Hardware Description
3
4
1 Terminal block of alarm output 3 Terminal Block of PWR2 2 Terminal Block of PWR1 4 Grounding screw
2-21
DVS Series Industrial Ethernet Switches
DVS-016W01-MC01 / DVS-016W01-SC01
Front Panel
1 2
3
7
4
5
6
1 Event alarm DIP Switch 5 Speed LED 2 LED (ALARM / PWR1 / PWR2 / Fiber port speed LED) 6 LINK/ACT LED 3 Fiber Ethernet port 7 Series model name 4 Ethernet port
2-22
Bottom panel
1
2
Chapter 2 Hardware Description
3
4
1 Terminal block of alarm output 3 Terminal Block of PWR2 2 Terminal Block of PWR1 4 Grounding screw
2-23
DVS Series Industrial Ethernet Switches
2.2 Dimension
DVS-005I00/DVS-008I00/G005I00A/G008I00A /005W01/005W01-MC01/005W01-SC01
145.3(H) x 45(W) x 108.7(D) mm
DVS-008W01/008W01-MC01/008W01-SC01/008W01-MC02/008W01-SC02
2-24
145.3(H) x 75(W) x 108.7(D) mm
DVS-016W01/016W01-MC01/016W01-SC01
Chapter 2 Hardware Description
145.3(H) x 75(W) x 108.7(D) mm
2.3 LED Indicators
DVS-005I00 / DVS-008I00 / G005I00A / G008I00A
LED Color Status Description
PWR Green
100M Orange
Green ON The port is connected at a speed of 1000Mbps.
10/100/1000M
LINK/ACT Green
DVS-005W01 / DVS-008W01 / DVS-016W01
LED Color Status Description
ALARM Red
PWR1 Green
PWR2 Green
100M Orange
LINK/ACT Green
Orange ON The port is connected at a speed of 100Mbps.
ON The power is supplied normally.
OFF The power is not supplied.
ON The port is connected at a speed of 100 Mbps.
OFF The port is connected at a speed of 10 Mbps or disconnected.
OFF The port is connected at a speed of 10 Mbps or disconnected.
ON
Blinking The data is being transmitted.
OFF
ON The communication is interrupted, or there is a power failure.
OFF
ON The power is supplied normally.
OFF The power is not supplied.
ON The power is supplied normally.
OFF The power is not supplied.
ON The port is connected at a speed of 100 Mbps.
OFF The port is connected at a speed of 10 Mbps or disconnected.
ON The Network communication connection has been establi she d.
Blinking The data is being transmitted.
The Network communication connection has been established.
The Network communication connection has not bee n stablished.
The communication is not interrupted, or there is no power failure. The DIP switch is not enabled.
2-25
DVS Series Industrial Ethernet Switches
LED Color Status Description
LINK/ACT Green OFF The Network communication connection has not been stablished.
DVS-005W01-MC01 / DVS-005W01-SC01 / DVS-008W01-MC01 / DVS-008W01-SC01 / DVS-008W01-MC02 / DVS-008W01-SC02 / DVS-016W01-MC01 / DVS-016W01-SC01
LED Color Status Description
ON The communication is interrupted, or there is a power failure.
ALARM Red
PWR1 Green
PWR2 Green
100M Green 100M
(on the
RJ45 port)
LINK/ACT Green
Orange
OFF
ON The power is supplied normally.
OFF The power is not supplied.
ON The power is supplied normally.
OFF The power is not supplied.
ON The fiber port is connected at a speed of 100 Mbps.
OFF The fiber port is not connected.
ON The port is connected at a speed of 100 Mbps.
OFF The port is connected at a speed of 10 Mbps or disconnected.
ON The Network communication connection has b een established.
Blinking The data is being transmitted.
OFF The Network communicati on connection has not been stablished.
The communication is not interrupted, or there is no power failure. The DIP switch is not enabled.
2.4 Wiring the Redundant Power Inputs
Except the DVS-005I00, the DVS series switches are equipped with two sets of DC input (PWR1 / PWR2). Both sets of DC input can be connected to a wide range of power sou rces (12 to 48VDC). If one power source fails, the other live source can work as a backup to ensure that the machine operates normally.
Step 1: Insert the negative and positive DC wires into the terminal block, and make sure that the positive DC wire is connected to V1+ or V2+, and that the negative DC wire is connected to 0V.
Step 2: To prevent the loose DC wires , tighten the wire clamp screws on the terminal block connector with the flat-blade screwdriver.
Step 3: Insert the plastic terminal block conne ctor into the terminal block recepto r on the DVS series switch.
2-26
Chapter 2 Hardware Description
2.5 Wiring the Alarm Contact
The alarm contact is a dry relay. If one of the two power sources fails or the communication is interrupted, the contact will turns from an “OPEN” circuit to a “CLOSED” circuit. The relay can be connected to a 5A/24VDC power source.
A typical way to use the alarm is to connect the Alarm circuit to a warning light or buzzer in the control room. The light or buzzer could be set up to turn on when any of the above two conditions is detected.
2.6 Ethernet Interface
10/100Base-T(X) Connection The 10/100Base-T(X) ports of the DVS series swit ches are used to connect to Ethernet. They can
support MDI (NIC–type) and MDI-X (HUB/Switch-type) modes, the pin definition of the Ethernet cable is as follows.
PIN MDI Mode Definition MDI-X Mode Definition
1 Tx+ Rx+ 2 Tx- Rx­3 Rx+ Tx+ 6 Rx- Tx-
10/100/1000Base-T Connection The 10/100Base-T(X) or 10/100/1000Base-T ports of the DVS series switches are used to connect
to Ethernet. RJ45 ports support MDI (NIC–type) and MDI-X (HUB/Switch-type) modes, the pin definition of the Ethernet cable is as follows.
10/100Base-T(X) 1000Base-T
PIN MDI Mode MDI-X Mode PIN
1 Tx+ Rx+ TP0+ 2 Tx- Rx- TP0­3 Rx+ Tx+ TP1+ 4 n.c. n.c. TP2+ 5 n.c. n.c. TP2­6 Rx- Tx- TP1­7 n.c. n.c. TP3+ 8 n.c. n.c. TP3-
2-27
DVS Series Industrial Ethernet Switches
100Base-FX Connection
The products are US FDA CDRH AEL Class 1 product.
The output signal of the fiber port will damage the eyes Do not look directly at the fiber port.
In your fiber connection application, the RX port of DVS switches must connect to the TX port of the other fiber device and the TX port of DVS switches must connect to the RX port of the other fiber device.
Fiber Optic
Cable
MultiMode
SingleMode
Remark : (1) 62.5/125um fiber optic cable. (2) 50/125um fiber optic cable IEEE standard transmission distance is 2km for 50/125um or 62.5um fiber optic cable. Actually, up
to 2~5km distance is possible before dissipating the optical power budget of 8.5dBm~11dBm to a value below the Rx sensitivity. And 30km distance is possible before dissipating the optical power budget of 16dBm to a value below the Rx sensitivity.
Wavelength
1310nm -14dBm 1310nm -8dBm -15dBm -31dBm 16dBm 30km
Max TX
power
Min TX
power
-20dBm(1)
-22.5dBm(2)
RX
Sensitivity
-31dBm
Optical Budget
11dBm(1)
8.5dBm(2)
Distance
2~5km
2.7 DIP Switch Setting
ON: After the corresponding switch of the port is enabled, when
the communication is interrupted, the relay will form a “CLOSED” circuit, and the alarm LED will be on.
OFF: After the corresponding switch of the port is disabled, when
the communication is interrupted, the relay still forms an “OPEN” circuit, and the alarm LED will not be on.
2-28
Chapter 3 Installation
Table of Contents
3.1 DIN-Rail Mounting.....................................................................................3-2
3.2 Wall Mounting............................................................................................3-3
3-1
DVS Series Industrial Ethernet Switches
3.1 DIN-Rail Mounting
The attached metal DIN-Rail plate should already be fixed to the rear panel of DVS switch when you get it. If you want to mount DVS switch with DIN-Rail, please make sure that the stiff metal spring is towards the top, as shown in the following figures,
Mounting
Step 1: Hook the upper end of the DIN clip of the DVS series switch on the DIN-Rail. Step 2: Lightly push the DVS series swit ch toward the DIN-Rail un til they cont a ct each oth er closely.
Removal
Step 1: Insert the flat-blade screwdriver into the DIN clip and pull the DIN clip downward. Step 2: Pull the DVS series switch, and you can remove it from the DIN-Rail.
3-2
Chapter 3 Installation
3.2 Wall Mounting
Step 1: Insert the wall mou nting bracket into the slot o n the rear p a nel of the DV S serie s swit ch, and tighten the screw on it, as shown in the diagram below .
Step 2: Place the wall mounting bra c ket in an appropriate position, and tighten the two screws on the bracket and the DIN clip.
Please install the DVS with necessary airflow applied, and sufficient space around it to allow heat dissipation.
3-3
Chapter 4 Functional Description
Table of Contents
4.1 Auto MDI/MDI-X Connection.....................................................................4-2
4.2 Auto-Negotiation and Speed Sensing........................................................4-2
4.3 Stored and Forward...................................................................................4-2
4.4 Addresses Capability and Learning...........................................................4-2
4.5 Quality of Service and VLAN Tagging ........................................................4-2
4.6 Broadcast Control......................................................................................4-2
4-1
DVS Series Industrial Ethernet Switches
4.1 Auto MDI/MDI-X Connection
The Auto MDI/MDI-X function let users connect DVS switch es’ 10/100Base-T(X) ports to any kind of Ethernet device. You don’t need to pay attention to the type of Ethernet cable being used for the connection. This means that you can use either a straight-forward cable or cross-over cable to connect DVS switches to Ethernet device.
4.2 Auto-Negotiation and Speed Sensing
All of DVS switch’s RJ45 Ethernet ports could independently support auto-negotiation for speeds in the 10BaseT and 100Base-T(X) modes, with operation according to the IEEE 802.3u standard. It means that it could support some ports operating in 10 Mbps and the others ports operating in 100Mbps in the same time.
Auto-negotiation happens when a RJ45 cable connection is made, and then each time a LINK is enabled, DVS switches advertises its capability for using either 10Mbps or 100Mbps transmission speeds, with the device at the other end of the cable expected to similarly advertise. Depending on what type of device is connected, this will result in agreement to operate in a speed of either 10Mbps or 100Mbps.
4.3 Stored and Forward
DVS switches could support the packet size between 64 bytes to 1522 bytes. They could store the traffic packets when the buffer of the receiver device in the other size of the internet line is full. DVS switches could store the packages until the receiver device could process the new package, DVS switches will restart to send the stored package to the receiver.
4.4 Addresses Capability and Learning
DVS switches has address learning engine to learn the source address of ingress frames. Up to 8K MAC addresses and port number mappings can be stored in the ad dress database. When a new MAC address found that is not in the MAC address mapping database. DVS swit ches could self-learning the message of the MAC address and place it into the MAC datab ase. It means that DVS switches could automatically support more internet devices in the application.
4.5 Quality of Service and VLAN Tagging
DVS switches has another feature that is different from other unmanaged switches, that is DVS switches could support high speed and non-blocking to transfe r the packets with VLAN tagging or the 4 traffic classes QoS packet. The priority from high to low is 7 to 0. The 4 set s priorities a re “7,6”, “5,4” , “3,0”, “2,1”. The highest level priorities are 7and 6 for the application as RIP and OSPF protocol routing updated. The priority “5,4” is for the delay-sensitive application as video and audio application. The priority “3,0” is for the control-load business critical traffic application. The priority “2,1” i s the lowest priority for the application tha t don’t need any application setting. This feature could let the network application be more flexible and it will not limit the networks setting cause of the packet types.
application as streaming multi-media and
4.6 Broadcast Control
When some network device work abnormal, it maybe will send out to many broadcast p acket s and it maybe will paralysis the Ethernet traffic. DVS-008/016W series have Broadcast control function, this feature could limit the broadcast packet traffic under the 10% full speed packet traffic and it could avoid the abnormal broadcast packet to paralysis the Ethernet traf fic and the user has more stable Ethernet environment.
4-2
Loading...