Delta Products DRP024V060W1BA Engineering Guide

0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
110%
-20 -10 0 10 20 30 40 50 60 70 80
Ambient Temperature (C)
Percentage of Max Load (%)
Switch Mode Power Supply DRP024V060W1BA
Engineering Data
Derating Curve (Both of Horizontal and Vertical)
o Model: DRP024V060W1BA
Note:
1. Do not use the device in areas outside
2. Based on the above graph, if the
6/13 Rev: 00, 1/10/2011
of the shaded portion shown in the above graph. Internal parts may gradually deteriorate and become damaged.
ambient temperature is greater than 50°C, the output capacity has to be reduced by 2.5% per Celsius temperature increase. If not, the device will go into over-temperature protection by switching off i.e. device will go into bouncing mode. It will
recover when ambient temperature drops to 50°C or output capacity is reduced as recommended in the graph.
3. If the device has to be mounted in any
other direction, please contact your service provider for more details.
4. In order for the device to function in
the manner intended, it is also necessary to observe a lateral spacing of 2cm from other equipments.
5. Depending on the ambient temperature
and output capacity of the device, the device housing can be very hot!