Delta Products Delta lndustrial Ethernet Catalog

Automation for a Changing World
Delta lndustrial Ethernet
Matched to Maximize
Delta Industrial Ethernet Products and Solutions (IES)
Adapting to the diversity of network communication applications, Delta’s IES series
industrial Ethernet products and solutions offer an abundant selection with excellent
quality in compact and durable designs. From Ethernet switches, IEEE 802.11 wireless
communication, mobile wireless communication, serial device servers to protocol gateways,
guarantees a seamless device integration that satisfies critical system applications in
industrial environments.
1
Table of Contents
Ethernet Switches
Tailoring to industrial applications that require highly reliable network systems, Delta's DVS series managed and unmanaged Ethernet switches provide better system performance with functions such as the redundant self-healing ring, high-end layer 2 management, and a wide-operating temperature from -40°C to 75°C. The EMC noise immunity complies with IEC standards and attains a high level 3/4. The intuitive design of the operating interface provides users with easy access and convenience.
Wireless IEEE 802.11
Delta helps users construct a reliable industrial wireless network by the WLAN products compatible with multiple communication protocols, such as IEEE 802.11 a/n in 5GHz or IEEE 802.11 b/g/n in 2.4GHz. Adopting Multiple-input and Multiple-output (MIMO) technology enables the network bandwidth reach 450Mbps. Delta WLAN products support multiple wireless connectors, including wireless access points, WDS, and clients for easy and economical construction of wireless LANs. The built-in 3-in-1 serial ports directly connect to industrial controllers, saving the effort and cost of cable connection. The built-in gateway for MODBUS, the most common industrial communication protocol, converts MODBUS Serial to MODBUS TCP, seamlessly interconnecting the existing equipment with the Ethernet communication network.
1
Industrial Ethernet Products and Solutions
Industry
3
Intelligent Transportation System
Wind Power
RGV Intelligent Warehouse Carriage Automation System
Solar Power
Automated CNC Production Line
13
Ethernet Switches
L2 Management Functions
Managed Switches
Unmanaged Switches
PoE+ Managed Switches
PoE+ Unmanaged Switches
SFP Fiber Transceivers
IEEE 802.11 WLAN
50
Wireless Management
Wireless AP
High-gain Antennas
IIoT Routers
60
Cloud Routers
VPN Routers
Ethernet Corverters
70
Protocol Converters
2
Industry
Intelligent Transportation System
DT3
The Intelligent Transportation System (ITS) integrates advanced electronic, information and sensing technologies for real-time transportation management of pedestrians, roads and traffic. The ITS effectively improves the safety, convenience, and efficiency of transportation, reducing carbon emissions from transportation and its impact on the environment, and supporting economic
Ethernet Switches
development.
Freeway Traffic Flow Monitoring System
CMS Real-Time Trafc Message Display System
Tunnel Signal and Alarm Monitoring System
Electronic Toll Collection System
DVS-110W02-3SFP
DVS-110W02-3SFP
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
7-port FE + 3-port GbE Combo Managed Ethernet Switch
IEEE 802.11 WLAN IIoT Routers
GbE ber port to enhance backbone
transmission
► STP / RSTP / MSTP for network
redundancy to ensure network reliability
► IP40 metal case, -40°C to 75°C
operating temperature
DVW-W02W2-E2
IEEE 802.11 a/b/g/n Wireless AP/WDS/Client/Gateway
► IEEE 802.11n up to 450Mbps data rate
► Supports 2-port RS-232 / 422 / 485 to
Ethernet Device Server
► IP40 metal case, -40°C to 75°C
operating temperature
DVS-G008I00A
8-port GbE Unmanaged Ethernet Switch
► Full GbE ports to enhance transmission
bandwidth
Ethernet Converters
► Jumbo frame size up to 9216 Bytes
► IP40 metal case, -10°C to 60°C operating
temperature
Exhaust Blower
HMI
Vehicle Detector
Visibility Sensor
Wind Sensor
Smoke Sensor
RTU-EN01
AH500
PV
8
8
8
8
SV
8
8
8
8
AT
OUT
ALM
SET
Temperature Sensor
DVS-110W02-3SFP
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
Air Detector
Fire Alarm
88
8
co
IFD9506
Serial-to-Ethernet MODBUS Converter
► RS-485 signal isolation protection
► Supports MODBUS TCP protocol
► Smart on-line monitoring function
3
DVS-110W02-3SFP
ETHERNET
R
1
3
DVW-W02W2-E2
Industry
GbE Fiber
Ethernet
Serial
I/O Sensor
Ethernet Switches
ALARM
1
2
PWR1
RESET
2
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
DVW-W02W2-E2
1
Antenna
2
DVW-W02W2-E2
3
TR1
OFF
ON
COM1
TR2
OFF
ON
TXD-
PWR2
COM2
STATUS
PWR1
TXD+
DCD RXD+ (D+)
COM1 RX
DI
TXD-
RXD RXD­(D-)
TXD+
TXD
COM2 RX
COM1 TX
DCD
GND
RXD+
DTR
(D+)
RXD
RS-422/485
CLIENT MODE
COM2 TX
RXD-
GND
(D-)
AP/BRIDGE
TXD
RS-232
ALARM
MODE
GND
DSR
DTR
RS-422/485
RTS
GND
RS-232
CTS
DSR
RTS
CONSOLE
10/100/
CTS
1000M
LAN1 LAN2
10/100/ 1000M
RESET
LINK / ACT
LINK / ACT
1
Antenna
PWR2
STATUS
PWR1
COM1 RX
DI
COM2 RX
COM1 TX
CLIENT MODE
COM2 TX
AP/BRIDGE
ALARM
MODE
CONSOLE
RESET
Trafc Gate
2
DVW-W02W2-E2
TR1
OFF
ON
COM1
TXD-
TXD+
DCD RXD+ (D+)
RXD RXD­(D-)
TXD
GND
DTR
RS-422/485
GND
RS-232
DSR
RTS
CTS
10/100/
1000M
LAN1 LAN2
LINK / ACT
3
TR2
OFF
ON
COM2
TXD-
TXD+
DCD RXD+ (D+)
RXD RXD­(D-)
TXD
GND
DTR
RS-422/485
GND
RS-232
DSR
RTS
CTS
10/100/
1000M
LINK / ACT
POWER
RUN
ERROR
COM1
RUN
STOP
COM1
DVP-12SE
DVP-12SE
Trafc Lights
S/S
X0
X1
X2
X3
IN
X4
X5
X6
X7
C0
Y0
Y1
OUT
Y2
Y3
SG
COM3+ COM3-
Ethernet
IFD9506
RS-232
RS-485
POWER
DATA
BAUDRATE
FORMAT
SLAVE ADDRESS
88
LINK/ACT
RSSET
RS485
1
10
SC
D -D+X2X1X0
S/S
24V
0V
Trafc Lights
IP CAM
DVS-G008I00A
DVS-008
PWR
1
6
7
100M
LINK
8
ACT
POWER
RUN
ALARM
RTU-485
RS-485
ID 7
DIP
ID 6 ID 5 ID 4 ID 3 ID 2 ID 1
1 2 3 4 5 6 7 8
ON
ID 0
PA 3 PA 2
DIP
PA 1 PA 0 DR 2 DR 1 DR 0
1 2 3 4 5 6 7 8
ON
A / R
RTU-485
IP CAM
ETC Tag Reader
DVS-110W02-3SFP
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
IEEE 802.11 WLAN IIoT Routers
Ethernet Converters
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
DVS-110W02-3SFP
4
Industry
Wind Power
Wind power has emerged as an alternative energy solution in recent years. Wind power plants are
typically located in remote areas, often within a vast territory. The ring network of ber optic Ethernet is
widely adopted for data transmission and management and real-time monitoring of power generation panels. These plant locations can be harsh and hazardous, with a large diurnal temperature variation.
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers
System reliability and transmission precision can only be guaranteed with highly noise-immune and durable network devices.
DVS-110W02-3SFP
7-port FE + 3-port GbE Combo Managed Ethernet Switch
GbE ber port to enhance backbone
transmission
► STP / RSTP / MSTP for network
redundancy to ensure network reliability
► IP40 metal case, -40°C to 75°C
operating temperature
DVS-016 Series
16-port FE Unmanaged Ethernet Switch
► Broadcast Storm Protection
► Auto warning for link-down and power
failure by relay output
► IP40 metal case, -40°C to 75°C
operating temperature
Ethernet Converters
Control Center
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
GE8
100/
10/100
1000M
/1000M
LINK ACT
LINK
GE9
ACT
2/5
GE10
CONSOLE
100M
LINK ACT
DVS-110W02-3SFP
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
DVS-110W02­3SFP
DVS-110W02-3SFP
1
3/6
10/
4/7
5
GbE/FE Fiber
Ethernet
Serial
Industry
Ethernet Switches
DVS-016W01-MC01
AH500
PORT ALARM
1
2
3
4
1
DVS-016
ALARM
2
PWR1
3
PWR2
5
4
100M
TX
11
6
RX
12
2
7
13
8
3
14
9
100M
4
15
10
LINK ACT
16
DVS-110W02-3SFP
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
DVP-12SE
S/S
POWER
RUN
X0
ERROR
X1
COM1
X2
X3
IN
X4
RUN
X5
X6
X7
STOP
C0
Y0
Y1
OUT
COM1
Y2
Y3
SG
COM3+ COM3-
DVP-12SE
Ethernet
R
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
DVS-110W02-3SFP
IEEE 802.11 WLAN IIoT Routers
Ethernet Converters
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
DVS-110W02-3SFP
DVS-110W02-3SFP
Rectiers RTU-EN01 Inverters
6
Industry
RGV Intelligent Warehouse Carriage Automation System
Wireless signal transmission technology can be applied in various areas. Delta's DVW series matches with Leaky CoaXial Cable (LCX or Radiating Cable) to transform Wi-Fi into stable extension signals which can surround objects, walls, pillars, and transmit signals to every corner of the production
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers
line, enhancing Ethernet communication accessibility. They also offer high-speed real-time process capability. When applying the Delta DVW series and LCX to Rail Guided
they can assist factory operators carry materials, which enhances working efficiency and security for
maintenance personnel.
Industrial wireless warehouse automation and underground communication engineering
Wireless radio wave communication systems for rail transport and tunnel engineering
Provides automation and wireless communication solutions between floors in the same building
Vehicle (RGV) systems,
DVW-W02W2-E2
IEEE 802.11 a/b/g/n AP/WDS/Client/Gateway
► IEEE 802.11n up to 450Mbps data rate
► Supports 2-port RS-232/422/485 to
Ethernet Device Server
► IP40 metal case, -40 to 75°C operating
temperature
AH500 Series
Mid-range PLC
► Utilizes 32-bit processor ► Max. I/O points:
DIO: Max. 4,352 points AIO: Max. 544 channels RIO: >100,000 points
Ethernet Converters
► Program capacity: Max.
384 k steps (1.5 MB)
► Data register (D+L): 256 k words
► Excellent program execution speed:
LD instruction execution speed: 0.02 μs
► CPU built-in with fully isolated RS-232 / 422 / 485, Mini-
USB, Ethernet and SDHC card slot
RGV
AH PLC Master
1
Antenna
2
DVW-W02W2-E2
3
TR1
OFF
ON
COM1
TR2
OFF
ON
TXD-
PWR2
COM2
STATUS
PWR1
TXD+
DCD RXD+ (D+)
COM1 RX
DI
TXD-
RXD RXD­(D-)
TXD+
TXD
COM2 RX
COM1 TX
DCD
GND
RXD+
DTR
(D+)
RXD
RS-422/485
CLIENT MODE
COM2 TX
RXD-
GND
(D-)
AP/BRIDGE
TXD
RS-232
ALARM
MODE
GND
DSR
DTR
RS-422/485
RTS
GND
RS-232
CTS
DSR
RTS
CONSOLE
10/100/
CTS
1000M
LAN1 LAN2
10/100/ 1000M
RESET
LINK / ACT
LINK / ACT
DVW Client Mode
C200
7
Ethernet
Coaxial Cable
Leaky Coaxial Cable
Industry
Ethernet Switches
AH PLC MasterDVW AP Mode
1
Antenna
2
DVW-W02W2-E2
3
TR1
OFF
ON
COM1
TR2
OFF
ON
TXD-
PWR2
COM2
STATUS
PWR1
TXD+
DCD RXD+ (D+)
COM1 RX
DI
TXD-
RXD RXD­(D-)
TXD+
TXD
COM2 RX
COM1 TX
DCD
GND
RXD+
DTR
(D+)
RXD
RS-422/485
CLIENT MODE
COM2 TX
RXD-
GND
(D-)
AP/BRIDGE
TXD
RS-232
ALARM
MODE
GND
DSR
DTR
RS-422/485
RTS
GND
RS-232
CTS
DSR
RTS
CONSOLE
10/100/
CTS
1000M
LAN1 LA N2
10/100/ 1000M
RESET
LINK / ACT
LINK / ACT
SCADA
IEEE 802.11 WLAN IIoT Routers
RGV
100M Leaky Coaxial Cable
Obstruction
RGV
SCADA AH PLC Master
Ethernet Converters
DVW AP Mode
1
Antenna
2
DVW-W02W2-E2
3
TR1
OFF
ON
COM1
TR2
OFF
ON
TXD-
PWR2
COM2
STATUS
PWR1
TXD+
DCD RXD+ (D+)
COM1 RX
DI
TXD-
RXD RXD­(D-)
TXD+
TXD
COM2 RX
COM1 TX
DCD
GND
RXD+
DTR
(D+)
RXD
RS-422/485
CLIENT MODE
COM2 TX
RXD-
GND
(D-)
AP/BRIDGE
TXD
RS-232
ALARM
MODE
GND
DSR
DTR
RS-422/485
RTS
GND
RS-232
CTS
DSR
RTS
CONSOLE
10/100/
CTS
1000M
LAN1 LA N2
10/100/ 1000M
RESET
LINK / ACT
LINK / ACT
8
Industry
R
Solar Power
Governments worldwide actively seek renewable clean energy for their electricity infrastructure in recent years. Solar power systems are one of the main programs. Most solar power plants are located in remote, vast areas of a country. The monitoring system constructed by Industrial Ethernet establishes highly stable and multiple redundant network systems for a power plant. It also facilitates
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers
real-time monitoring and continuous production by the highest generating capacity.
DVS-108W02-2SFP
6-port FE + 2-port GbE Combo Managed Ethernet Switch
GbE ber port to enhance backbone transmission
► ONE RING, ONE CHAIN for rapid
network redundancy to ensure network reliability , recovery time less than 20ms
► IP40 metal case, -40°C to 75°C
operating temperature
DVS-G408W01
IP Camera
1
2
O
N
PWR1
PWR2
ALARM
8
7
6
5
DVS-G408W01
4
3
2
1
PoE10/100 /1000M
8-port GbE+ PoE+ Unmanaged Ethernet Switch
► 8 10 / 100 / 1000 Base-T PoE+ (PSE) ports.
Based on IEEE 802.3at standard up to
30 W per port
► Auto warning by relay output for
power failure
► IP30 metal case, -40°C to 70°C
operating temperature
DX-2100RW
3G Cloud Router
► UMTS / HSPA+ : 800 / 850 , 900,
AWS1700, 1900, 2100 MHz
► Supports DIACloud Cloud Management
Platform
► IP30 metal case, -20°C to 70°C
Ethernet Converters
operating temperature
DVP-SE
Advanced Slim PLC
S/S
POWER
RUN
X0
ERROR
X1
COM1
X2
X3
IN
X4
RUN
X5
X6
X7
STOP
C0
Y0
Y1
OUT
COM1
Y2
Y3
SG
ALARM
COM3+
1 2
1
PWR1
COM3-
DVP-12SE
R
PV Inverter (DC/AC)
RESET
2
3 4
PWR2
3
DI1
4
DI2
D
V S
­1 0
8 W
0 2
­2 S
F
Ethernet
P
GE7
1 0 0
1
/
0 / 1 0
0
1 0 0
/
0
1
M
0 0 0 M
L I N K A C T
1/4
L I N
GE8
K A CT
2/5
1 0
CONSOLE
/ 1 0 0 M
3/6
L I N K A C T
S/S
POWER
RUN
X0
ERROR
X1
COM1
X2
X3
IN
X4
RUN
X5
X6
X7
STOP
C0
Y0
Y1
OUT
COM1
Y2
Y3
SG
COM3+ COM3-
DVP-12SE
ALARM
Ethernet
1 2
1
PWR1
RESET
2
3 4
PWR2
3
DI1
4
DI2
D
V S
­1 0 8 W
0 2
­2
S F P
GE7
1 0 0
1
/
0 / 1 0
0
1
0 0
/
0
1
M
0 0 0 M
L
I N K
A
C T
1/4
L I N
GE8
K A CT
2/5
1 0
CONSOLE
/ 1 0 0 M
3/6
L I N K A C T
Battery Bank
Specic Solar Tracking instruction
► Program capacity: 16 K steps, Data
register: 12 K words; Higher execution
Utility Grid
speed, LD:0.64 µs, MOV:2 µs
► Built-in MODBUS TCP and EthernNet/IP
9
R
R
R
GbE Fiber
Ethernet
Power Line
Industry
Ethernet Switches
PoE+ switch (DVS-G400 Series)
Gigabit Fiber Ring
S/S
POWER
RUN
X0
ERROR
X1
COM1
X2
X3
IN
X4
RUN
X5
X6
X7
STOP
C0
Y0
Y1
OUT
COM1
Y2
Y3
SG
COM3+ COM3-
DVP-12SE
Ethernet
PLC (DVP Series)
ALARM
1 2
1
PWR1
RESET
2
3 4
PWR2
3
DI1
4
DI2
D
V S
­1 0 8 W
0
2
­2 S
F P
GE7
1 0 0
1
/
0 / 1
0 0
1 0 0
/
0
1
M
0 0
0 M
L I N
K A C T
1/4
L I N
GE8
K A CT
2/5
1 0
CONSOLE
/ 1 0 0
M
3/6
L I N
K A C
T
ALARM
1 2
1
PWR1
RESET
2
3 4
PWR2
3
DI1
4
DI2
D V
S
­1
0 8
W 0
2
­2 S
F P
GE7
1 0 0
1
/
0 / 1
0 0
1
0 0
/
0
1
M
0 0
0 M
L
I N K
A
C T
1/4
L I N
GE8
K A CT
2/5
1 0
CONSOLE
/ 1 0 0
M
3/6
L I N
K A C
T
Managed Switch (DVS-100 Series)
Gigabit Fiber Ring
POWER
RUN
ERROR
COM1
RUN
STOP
OUT
COM1
COM3+ COM3-
DVP-12SE
Ethernet
10/100M
5
1
PWR1
DVS-328R02-8SFP
R.M / CPLG.R
ALARM
PWR2
PWR3
PWR1
DI
PWR3
-/N +/L
0V V+
C.HD / C.TL
3 5 7 9
1
2
4 6 8 10
0V V+
RESET
PWR2
V+ V-
678910
234
DI
ALARM
LINK/ACT 100M LINK/ ACT 10/1 00/10 00M LINK/ACT LINK/ ACT100/1000M
2123252725
15 171921
11
23
13
18 20 22242224262826
FECombo GEComboFE
12 14 16
Managed Switch (DVS-300 Series)
27
CONSOLE
28
IEEE 802.11 WLAN IIoT Routers
DX
­2
1
0
0
R e
a d y
3 G
T X
R S
4 8
5 R X
L A
N
T X
PW
R
SD
R S
2 3
2 R X
1
2
3
4
5
2
­R X
D
5
4
3
-
3
T XD
2
1
5
­G N
D
7
­R
6
T S
7
8
9
8
­C T S
R S2
3
9
2
8
7
6
R S4
8
5
DX
­2
1
0
0
R
e a
d y
3 G
T X
R S
4 8
5
R
X L A
N
T X
PW
R
SD
R S
2 3
2
R
X
1
2
3
4
5
2
­R X
D
5
4
3
-
3
T XD
2
1
5
­G N
D
7
­R
6
T
S
7
8
9
8
­C T
S
R
S2
3
9
2
8
7
6
R
S4 8
5
S/S
X0
X1
X2
X3
IN
X4
X5
X6
X7
C0
Y0
Y1
Y2
Y3
SG
ALARM
1 2
1
PWR1
RESET
2
3 4
PWR2
3
DI1
4
DI2
D V
S
­1
0 8 W
0 2
­2 S F
P
GE7
1 0 0
1
/
0 / 1 0 0
1
0 0
/
0
1
M
0 0 0 M
L
I N K
A
C T
1/4
L I N
GE8
K A CT
2/5
1 0
CONSOLE
/ 1 0 0 M
3/6
L I N K A C T
3G Cloud Router (DX-2100 Series)
1
­G
N D
2
­D
-
3
­D
+
S/S
POWER
RUN
X0
ERROR
X1
COM1
X2
X3
IN
X4
RUN
X5
X6
X7
STOP
C0
Y0
Y1
OUT
COM1
Y2
Y3
ALARM
1 2
1
PWR1
RESET
SG
2
3 4
PWR2
COM3+
3
DI1
COM3-
4
DI2
DVP-12SE
S/S
POWER
RUN
X0
ERROR
X1
COM1
X2
X3
IN
X4
RUN
X5
X6
X7
STOP
C0
Y0
Y1
OUT
COM1
Y2
Y3
SG
COM3+ COM3-
DVP-12SE
Ethernet
R
Ethernet
ALARM
1 2
1
PWR1
RESET
2
3 4
PWR2
3
DI1
4
DI2
D V S
­1 0
8 W
0 2
­2 S F
P
GE7
1 0 0
1
/
0 / 1 0 0
1
0 0
/
0
1
M
0 0 0 M
L
I N K
A
C T
1/4
L I N
GE8
K A CT
2/5
1 0
CONSOLE
/ 1 0 0 M
3/6
L I N K A C T
Managed Switch (DVS-100 Series)
D V
S
­1
0 8 W
0 2
­2 S F
P
GE7
1 0 0
1
/
0 / 1 0 0
1
0 0
/
0
1
M
0 0 0 M
L
I N K
A
C T
1/4
L I N
GE8
K A CT
2/5
1 0
CONSOLE
/ 1 0 0 M
3/6
L I N K A C T
1
­G N
D
2
­D
-
3
­D +
INTERNET
1 2
O N
PWR1
PWR2
ALARM
8
7
6
5
DVS-G408W01
4
3
2
1
PoE10/100 /1000M
PoE+ Switch (DVS-G400 Series)
Remote Control Center
IP Camera
Ethernet Converters
10
Industry
Automated CNC Production Line
Unmanned factories is the ultimate goal for industrial automation. The logistics of an automated production line is an indispensable part of that goal. The use of robots, unmanned vehicles and other equipment, and data transmission and exchange via an industrial wireless network allows immediate
acquisition of the status of the production line from the control room, and signicantly increases the
overall productivity and quality.
Ethernet Switches
DVW-W02W2-E2
IEEE 802.11 a/b/g/n Wireless AP/WDS/Client/Gateway
► IEEE 802.11n up to 450 Mbps data
rate
► Supports 2-port RS-232/422/485 to
Ethernet Device Server
► IP40 metal case, -40°C to 75°C
operating temperature
PLC (AH500 Series)
IEEE 802.11 WLAN IIoT Routers
DVS-008 Series
8-port FE Unmanaged Ethernet Switch
► Broadcast Storm Protection
► Auto warning for link-down and power
failure by relay output
► IP40 metal case, -40°C to 75°C
operating temperature
AH500 Series
Mid-range PLC
► Utilizes 32-bit processor ► Max. I/O points:
DIO: Max. 4,352 points AIO: Max. 544 channels RIO: >100,000 points
► Program capacity: Max.
384 k steps (1.5 MB)
► Data register (D+L): 256 k words
► Excellent program execution speed:
LD instruction execution speed: 0.02 μs
Ethernet Converters
► CPU built-in with fully isolated RS-232 / 422 / 485, Mini-
USB, Ethernet and SDHC card slot
PORT ALARM
1
2
3
DVS-008
4
1
ALARM
2
PWR1
3
PWR2
4
TX
100M
RX
5
TX
3
2
6
RX
4
4
7
100M
5
LINK ACT
8
Unmanaged Switch (DVS-008 Series)
DVP-SE Series
Advanced Slim PLC
► Remote I/O function is suitable for
distributed sequence control
► Program capacity: 16k steps, Data register:
12k words; Higher execution speed, LD:0.64µs, MOV:2µs
► Built-in MODBUS TCP and EtherNet/IP
11
Industry
R
R
S/S
POWER
DVPEN01
RUN
X0
POWER
ERROR
X1
RS-232
COM1
X2
100M
X3
IN
LINK
X4
RUN
X5
X6
X7
STOP
ON
C0
Y0
Y1
OUT
COM1
Y2
Y3
SG
COM3+ COM3-
DVP-12SE
Ethernet
R
PLC (DVP Series)
1
Antenna
2
DVW-W02W2-E2
3
TR1
OFF
ON
COM1
TR2
OFF
ON
TXD-
PWR2
COM2
STATUS
PWR1
TXD+
DCD RXD+ (D+)
COM1 RX
DI
TXD-
RXD RXD­(D-)
TXD+
TXD
COM2 RX
COM1 TX
DCD
GND
RXD+
DTR
(D+)
RXD
RS-422/485
CLIENT MODE
COM2 TX
RXD-
GND
(D-)
AP/BRIDGE
TXD
RS-232
ALARM
MODE
GND
DSR
DTR
RS-422/485
RTS
GND
RS-232
CTS
DSR
RTS
CONSOLE
10/100/
CTS
1000M
LAN1 LAN2
10/100/ 1000M
RESET
LINK / ACT
LINK / ACT
WiFi AP (DVW Series)
1
Antenna
2
DVW-W02W2-E2
3
TR1
OFF
ON
COM1
TR2
OFF
ON
TXD-
PWR2
COM2
STATUS
PWR1
TXD+
DCD RXD+ (D+)
COM1 RX
DI
TXD-
RXD RXD­(D-)
TXD+
TXD
COM2 RX
COM1 TX
DCD
GND
RXD+
DTR
(D+)
RXD
RS-422/485
CLIENT MODE
COM2 TX
RXD-
GND
(D-)
AP/BRIDGE
TXD
RS-232
ALARM
MODE
GND
DSR
DTR
RS-422/485
RTS
GND
RS-232
CTS
DSR
RTS
CONSOLE
10/100/
CTS
1000M
LAN1 LAN2
10/100/ 1000M
RESET
LINK / ACT
LINK / ACT
WiFi Client (DVW Series)
POWER
RUN
ERROR
COM1
RUN
STOP
COM1
DVP-12SE
S/S
X0
X1
X2
X3
IN
X4
X5
X6
X7
C0
Y0
Y1
OUT
Y2
Y3
SG
COM3+ COM3-
Ethernet
Ethernet
Ethernet Switches
CNC Machine
IEEE 802.11 WLAN IIoT Routers
Robot Arm
S/S
POWER
DVPEN01
RUN
X0
POWER
ERROR
X1
RS-232
COM1
X2
100M
X3
IN
LINK
X4
RUN
X5
X6
X7
STOP
ON
C0
Y0
Y1
OUT
COM1
Y2
Y3
SG
COM3+ COM3-
DVP-12SE
Ethernet
Material zone
1
Antenna
2
DVW-W02W2-E2
3
TR1
OFF
ON
COM1
TR2
OFF
ON
TXD-
PWR2
COM2
STATUS
PWR1
TXD+
DCD RXD+ (D+)
COM1 RX
DI
TXD-
RXD RXD­(D-)
TXD+
TXD
COM2 RX
COM1 TX
DCD
GND
RXD+
DTR
(D+)
RXD
RS-422/485
CLIENT MODE
COM2 TX
RXD-
GND
(D-)
AP/BRIDGE
TXD
RS-232
ALARM
MODE
GND
DSR
DTR
RS-422/485
RTS
GND
RS-232
CTS
DSR
RTS
CONSOLE
10/100/
CTS
1000M
LAN1 LAN2
10/100/ 1000M
RESET
LINK / ACT
LINK / ACT
Production zone
(Phase I)
1
Antenna
2
DVW-W02W2-E2
3
TR1
OFF
ON
COM1
TR2
OFF
ON
TXD-
PWR2
COM2
STATUS
PWR1
TXD+
DCD RXD+ (D+)
COM1 RX
DI
TXD-
RXD RXD­(D-)
TXD+
TXD
COM2 RX
COM1 TX
DCD
GND
RXD+
DTR
(D+)
RXD
RS-422/485
CLIENT MODE
COM2 TX
RXD-
GND
(D-)
AP/BRIDGE
TXD
RS-232
ALARM
MODE
GND
DSR
DTR
RS-422/485
RTS
GND
RS-232
CTS
DSR
RTS
CONSOLE
10/100/
CTS
1000M
LAN1 LAN2
10/100/ 1000M
RESET
LINK / ACT
LINK / ACT
Production zone
(Phase II)
Ethernet Converters
12
Industry
Ethernet Switches
Functions
Layer 2 Network Management ................................................................................................................................................................ 14
Managed Switches
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
DVS-328 Series: Managed Industrial 20-Port FE + 4-Port FE Combo 100Base-SFP + 4-Port GbE Combo 100/1000Base-SFP Rack
Mount Ethernet Switches ............................................................................................................................................. 18
DVS-110 Series: Managed Industrial 7-Port FE + 3-Port GbE Combo 100/1000Base-SFP Ethernet Switches ....................................... 21
DVS-109 Series: Managed Industrial 8-Port FE + 1-Port GbE Ethernet Switches ................................................................................... 24
DVS-108 Series: Managed Industrial 6-Port FE + 2-Port GbE Combo 100/1000Base-SFP Ethernet Switches ....................................... 27
Unmanaged Switches
DVS-G008I/G005I00A Series: Unmanaged Industrial 5 and 8-Port GbE Ethernet Switches ................................................................... 30
DVS-016 Series: Unmanaged Industrial 16-Port FE Ethernet Switches .................................................................................................. 32
DVS-008 Series: Unmanaged Industrial 8-Port FE Ethernet Switches .................................................................................................... 34
DVS-005 Series: Unmanaged Industrial 5-Port FE Ethernet Switches .................................................................................................... 36
PoE Managed Switches
DVS-G512 Series: IEEE 802.3 af/at PoE+ Managed Industrial 8-Port GbE (PSE)
+ 4-Port 100/1000Base-SFP Ethernet Switches ...................................................................................................................................... 38
PoE Unmanaged Switches
DVS-G408 Series: IEEE 802.3af/at PoE+ Unmanaged Industrial 8-Port GbE Ethernet Switches ........................................................... 41
DVS-G406 Series: IEEE 802.3af/at PoE+ Unmanaged Industrial 4-Port GbE + 2-Port 100/1000Base-SFP Ethernet Switches
DVS-G402 Series: 2 10/100/1000Base-T Industrial IEEE 802.3af/at PoE+ Injectors .............................................................................. 45
DVS-G401 Series: 1 10/100/1000Base-T Industrial IEEE 802.3af/at PoE+ Splitters
.............................................................................. 47
............ 43
SFP Fiber Transceivers
LCP-GbE Series: 1-Port Gigabit Ethernet SFP Fiber Transceivers ......................................................................................................... 49
LCP-1FE Series: 1-Port Fast Ethernet SFP Fiber Transceivers ................................................................................................................51
13
Layer 2 Network Management
Network Redundancy Technology
IEEE published the 802.1D Spanning Tree Protocol (STP) in 1998, and in 2004 announced 802.1w Rapid Spanning Tree Protocol (RSTP), which is an enhancement to STP. These network protocols are used to construct backup paths for transmission when a link fails and are applied in network structures with demands for high reliability. In current industrial automation and critical system applications, as the high
demand for faster convergence time grows, STP and SRTP’s speed, whose unit of convergence time is seconds, becomes insufcient. Delta
thoroughly understands customers’ needs from different industries. To meet the high demand for speed and reliability, Delta introduced ONE RING and ONE CHAIN ultra-speed redundant protocol to satisfy our customers’ needs, which provides faster speed and more functions than STP and RSTP.
ONE RING
Network self-healing brings most recovery
Delta's proprietary self-healing redundant ring technology is called ONE RING. ONE RING can enable redundant paths and provide self-healing recovery time of less than 20 milliseconds to ensure fluent data transmission with minimum loss when any nodes fail or meet default in a ring network. In addition, ONE RING offers customers the selection of Trunking Ring, Multi-Ring, Ring Coupling, and Dual-Homing modes to satisfy their specific needs. With strong ring network functions, ONE RING provides highly flexible and highly reliable network structures, which greatly save on wiring cost.
Industry
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Trunking Ring
Multi-Ring
Ring Coupling
Dual-Homing
ONE CHAIN
Multi-Network self-healing brings most efficient and trust
Delta's self-healing redundant chain technology is called“ONE CHAIN".
ONE CHAIN is a new generation of Network Redundancy Technology with unlimited expansion functions derived from the design concept of ONE RING.
ONE CHAIN is able to offer backup paths within 20 milliseconds when several network nodes fail at the same time to ensure fluent data transmission with minimum loss. Its high speed self-healing time is especially suitable for high-end automation network structures such as a Distributed Control System (DCS). ONE CHAIN is compatible with other existing large Internet backbone network switches, which saves costs for wiring and for changing new switches such as equipment, labor, and time.
14
Industry
PS05-A1
PS05-A1
PS05-A1
Advanced Network Management
VLAN
A Virtual Local Area Network (VLAN) is a network topology configured according to a logical scheme rather than a physical layout. VLANs allow users to break up switched environments into multiple broadcast domains, and can be used to combine any collection of LAN segments into an autonomous user group that
Ethernet Switches
appears as a single LAN. It enhances performance by conserving bandwidth and improves security by limiting traffic to specific domains. VLANs can be created statically by hand and dynamically through GVRP.
Trunking
The physical ports of a switch can be aggregated by a logical scheme into a group which forms a physical link. This link serves as a redundant path which enhances bandwidth and improves performance
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Quality of Service (QoS)
Network packet prioritization is a process which prioritizes the transmission of packets with a queue. It ensures prompt packet scheduling that is especially effective for delay-sensitive packets and audio or image transmissions with optimal quality of service
IP CAM
AH500
RTU
16AM10N
POWER
16AM10N
16AM10N
16AM10N
I/O0
I/O1
PULL
I/O2
I/O3
POWER
16AM10N
16AM10N
16AM10N
16AM10N
I/O0
I/O1
PULL
I/O2
I/O3
POWER
16AM10N
16AM10N
16AM10N
16AM10N
I/O0
I/O1
PULL
I/O2
I/O3
Top Priority
High Priority
Low Priority
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
ZONE A
16AM10N
I/O4
16AM10N
I/O4
16AM10N
I/O4
1
S/S
POWER
RUN
X0
ERROR
X1
COM1
X2
X3
IN
X4
RUN
X5
X6
X7
STOP
C0
Y0
Y1
OUT
COM1
Y2
Y3
SG
COM3+ COM3-
DVP-12SE
Ethernet
R
VLAN1
ALARM
1
PWR1
1
2
RESET
2
PWR2
3
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
Enhanced bandwidth
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
VLAN2
VLAN3
ALARM
1
PWR1
1
2
RESET
2
PWR2
3
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
Low High To p
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK
ACT
ZONE B
1
S/S
POWER
RUN
X0
ERROR
X1
COM1
X2
X3
IN
X4
RUN
X5
X6
X7
STOP
C0
Y0
Y1
OUT
COM1
Y2
Y3
SG
COM3+ COM3-
DVP-12SE
Ethernet
R
Server
Link Layer Discovery Protocol (LLDP)
The LLDP protocol is used by network devices for advertising their identity, capabilities, and any updates to neighboring devices on an IEEE 802.ab network. These messages are stored in SNMP MIB and can be searched through a network management system.
DHCP Relay Option 82 IP Assignment
DHCP Relay Option 82 delivers additional client information such as ports
connected, VLAN, as well as MAC addresses to a DHCP server for more exible
IP addresses assignment.
Enhanced Network Security Management
A complete set of security verication tools further ensures network security for
users. Multiple protection mechanisms are incorporated in network management to protect it from unauthorized network access during operation.
ALARM
1
1
2
PWR1
2
3
PWR2
4
3
DI1
4
DI2
GE8
SW B
GE9
GE10
CONSOLE
ALARM
1
1
2
PWR1
2
3
PWR2
4
3
DI1
4
DI2
GE10
CONSOLE
SW A
1. IP address request
RESET
DVS-110W02-3SFP
100/
10/100
1000M
/1000M
LINK ACT
1
LINK ACT
2/5
3/6
10/ 100M
4/7
LINK ACT
RESET
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
3/6
10/ 100M
4/7
LINK ACT
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
4. Your IP address
192.168.1.5
TACACS+
IEEE 802.1X
SNMP v3
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
I know I have neighbors
SW A, B, C, D
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
3. Your IP address
192.168.1.5
ACL
SSH
HTTPS
SW C
SW D
2. IP address request VLAN 8, Port 8
15
Industry
Simple Network Management Protocol (SNMP)
Delta Managed Ethernet Switches support v1, v2c and v3 versions of SNMP. For users, SNMP Trap messages allow real-time event alarms for authentication failures, cold/warm starts, link-downs, and many more.
MODBUS TCP & EtherNet/IP Manager
Delta Managed Ethernet Switches support MODBUS TCP and EtherNet/IP protocol for easy integration with an on-site industrial network management system. Users can monitor and manage the operational status via the graphical interface of Supervisory Control and Data Acquisition (SCADA) at any time. The consistency of communication protocols helps users save big on equipment management costs.
0x1000 : Port 1 link-up
0x1000
NMS
(Manager)
MODBUS TCP & EtherNet/IP
Smart Functions Well-tailored to Your Needs
Authentication
Cold/Warm start
Link-down
SCADA
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Relay Output for Event Alarms
Delta Managed Ethernet Switches have built-in relay output for event alarms. Any occurrence of preset default events and any digital inputs will trigger alarms. With real-time notification, on-site personnel can quickly diagnose and eliminate any incidents.
Digital Inputs
Designed for industrial environments, the DVS series industrial Ethernet switches easily connect to various industrial devices, such as PLCs or sensors. It delivers real-time alarms to users via relay output or email.
Redundant Power Inputs
The design of dual power inputs provides excellent integration with the common dual power supply design of critical systems, or with industrial environments. It secures switches from potential power impact and provides highly-reliable and uninterrupted network transmission.
Alarm Indicators
Adjust
DC OK
Adjust
DC OK
16
Industry
A Seamless Interconnection
USB Console Interface
A simple USB cable is all you need to carry out network management settings.
Ethernet Switches
Real-time Web Display
A real-time Web display tells users the connection status of each port with indicators on a Web page. With an uninterrupted network connection, users can manage operations in remote places at any time.
SFP DDM
Utilizing the built-in digital diagnostic monitor (DDM) function of the DVS series Industrial Ethernet Switches, users can continuously monitor the current operation
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
status of the Delta SFP ber transceiver and the transmission quality through a
datasheet displayed on the web.
DVS NB
USB cable
Watch Dog Timer
The hardware Watch Dog Timer restores switches from malfunctions caused by any reasons, such as an incorrect network topology or a malicious network attack. It ensures switches work properly in harsh industrial environments.
Delta IEXplorer Search Tool
IEXplorer provides friendly access to search for all IES products on the network. One simple click calls up the Web page for setting software functions.
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
GOOD
NG
CPU malfunction = 6 seconds = Auto Reset
17
DVS-328 series
Managed Industrial 20 10/100Base-T(X) + 4 10/100Base­T(X) combo 100Base-SFP + 4 10/100/1000Base-T combo 100/1000Base-SFP Rack Mount Ethernet Switch
2
3
Industry
Ethernet Switches
IPv6 address suitable for larger network and
neighbor discovery
Automatic IP assignment by DHCP/BootP server for
easy network construction
DHCP relay option 82 for sending DHCP requests
with clients’ identities to a DHCP server
Port-based DHCP server with IP and MAC binding
makes IP maintenance much easier
Q-in-Q double VLAN to distinguish multiple VLANs
SNMP v1/v2c/v3 facilitates the exchange of
management between network devices
Supports EtherNet/IP and MODBUS TCP protocols
that facilitates the remote management by SCADA
and other industrial devices
Proprietary ONE RING and ONE CHAIN high end
redundancy technology, easy to build multiple ring
topology, self-healing recovery time < 20ms
STP/RSTP/MSTP for network redundancy further
ensures reliability
QoS(IEEE 802.1p) and TOS/DSCP for mission-critical
applications
IEEE 802.1Q VLAN, MAC-based VLAN, IP Subnet-
based VLAN, VLAN isolation and GVRP optimize
network strategy
Enhanced network security with IEEE 802.1X,
TACACS+, SSH, HTTPS and SNMP v3
IEEE 802.3ad port trunking in parallel to increase the
link bandwidth
SNTP (simple network time protocol) for network clock
synchronization
Broadcast/Multicast / Unknown Unicast storm control
improves throughput problems
Loopback-Detection to avoid broadcast loops, and
shutdown the corresponding ports automatically
Cable diagnostic provides the mechanism to detect and
report potential cabling issues
Intelligent Access Control List(ACL)
MAC addresses locking function per port blocks
unauthorized access
USB console interface for easy connection with laptops
IGMP Snooping and GMVP prunes multicast trafc
RMON groups 1,2,3,9(history, statistics, alarms and
events) for enhanced ow management and analysis
CPU utilization displays the amount of works the CPU
handles
Port mirroring for Many-to-One ports online
troubleshooting
Versatile system le updates by TFTP, HTTPS or HTTP
DDM diagnosis function by SFP ber module
Auto warning by email, DI, relay, Syslog & SNMP trap
Compatible with various industrial protocols, including
EtherNet/IP, Pronet, CC-LINK IE and DNP 3.0
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Specications
TECHNOLOGY
Standard Compliance
IEEE 802.3 10Base-T
IEEE 802.3u 100Base-T(X) and 100Base-FX
IEEE 802.3ab 1000Base-T
IEEE 802.3z 1000Base-X
IEEE 802.3x Flow Control
IEEE 802.1D Spanning Tree Protocol
IEEE 802.1w Rapid Spanning Tree Protocol
• IEEE 802.1s Multiple Spanning Tree Protocol
• IEEE 802.1p Class of Service, Priority Protocols
• IEEE 802.1Q VLAN Tagging
• IEEE 802.1AD VLAN Q-in-Q
• IEEE 802.1X Port Authentication
• IEEE 802.3ad LACP Aggregation
• IEEE 802.1AB Link Layer Discovery Protocol
18
Processing Type
Store and Forward
IEEE 802.3x Flow control in
full duplex, back-pressure flow control in half duplex
Industry
Specications
INTERFACE
Fast Ethernet
RJ45 Ports
20 10/100Base-T(X), auto MDI/MDI-X, auto
negotiation
Fast Ethernet Combo Ports
RJ45 Ports:
4 10/100Base-T(X), auto MDI/MDI-X, auto
negotiation
SFP Ports:
Ethernet Switches
4 100Base-SFP
Gigabit Ethernet Combo Ports
RJ45 Ports:
4 10/100/1000Base-T, auto MDI/MDI-X, auto
negotiation
SFP Ports:
4 100/1000Base-SFP
PERFORMANCE AND SCALABILITY
Console Port
USB B-Type connector
LEDs
Device:
PWR1PWR2PWR3R.M/CPLG.RC.HD/ C.TLALARMDI
Ports:
100M(SFP port)100/1000M(SFP port) 10/100M(RJ45 port)10/100/1000M(RJ45 port)、LINK/ACT
Digital Inputs(DI)
1 set
0~+5V is OFF
+11V~30V is ON
Input current 6mA Max
Alarm Contacts(DO)
1 relay output
Carry current 2A @ 24V
Reset Button
1 set
DC
Switching Capacity
12.8Gbps, Wired speed, Non-blocking
switching fabric
Forwarding Rate
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
19Mpps
MAC Address Table
16K
MANAGEMENT
Software
STP/RSTP/MSTP, LACP, QoS, IGMP Snooping v1/v2/v3, IGMP Query v1/v2, GARP, GMRP, VLAN, VLAN Q-in-Q, VLAN unaware, SSH, DNS, HTTP, HTTPS, RADIUS, TACACS+, SNMP v1/v2c/v3, SNMP Traps, TFTP, RMON, LLDP, BootP Server/Client, DHCP Server/Client, DHCP L2 Relay, DHCP Relay Option 82, DHCP Option 66/67, RARP, Telnet, Syslog, SMTP, SNTP Server/Client, IPv6, MODBUS TCP, EtherNet/IP
Security
MAC filtering, HTTPS, SSH, 802.1x, TACACS+, SNMP v3
POWER REQUIREMENTS
Input Voltage
Installation: Front cabling. Industrial terminal block
LV: 2 sets 36 to 72VDC (Tested @ 36 to 60VDC)
HV: 1 set 85 to 264V
to 240VAC)
/ 88 to 370VDC (Tested @ 100
AC
Packet Buffer Memory
1.5M bits
IGMP Multicast Groups
256
Max. VLANs
255
Conguration
Web Browser, Cisco-like Telnet CLI, USB Local Console ,
MIB
MIB II, Bridge MIB, SNMP MIB, Ether-like MIB, Q-Bridge/
Input Current
LV: 0.75A
HV: 1.2A
Overload Current Protection
Present, Max. Input current 8A
Quality of Service
8 priority queues per port
DHCP/BootP Server
1,275 IP addresses
Jumbo Frame
9,216 Bytes
SNMP, MODBUS TCP, IEXplorer Utility
P-Bridge MIB, IF MIB, Traceroute MIB, TCP MIB, UDP MIB, IP MIB, RMON Group 1,2,3,9, Delta Private MIB
Reverse Polarity Protection
• Present (VDC input )
Buffer Time
Min. 12ms @ 48 VDC
PHYSICAL
Housing
IP40 metal case
Dimensions
44 mm(H) x 440 mm(W) x 257 mm (D)
ENVIRONMENTAL LIMITS
Operating Temperature
-25 to 70(-13 to 158 )
Weight
4,950g
Installation
19" Rack mounting and wall mounting
Storage Temperature
-40 to 85(-40 to 185 )
19
Ambient Relative Humidity
5% to 95% (non-condensing)
APPROVALS
Industry
Safety
UL 60950-1, IEC 60950-1, CCC
EMI
FCC 47 CFR Part 15 Subpart B Class A, IEC 61000-6-4, EN 55022(CISPR 22), EN 55032
EMS(IEC 61000-6-2)
IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11, IEC 61000-4-29
Environmental Type Tests
Cold Temperature:
IEC 60068-2-1
Dry Heat:
IEC 60068-2-2
Humidity:
IEC 60068-2-30
Shock:
IEC 60255-21-2
Freefall:
IEC 60068-2-32
Vibration:
IEC 60068-2-6
Hi-Pot:
1.5KV
Ordering Information
Product Port Combination Interface
Combo Port
Model Name
Operating
Temperature
10/100/1000Base-T and 100/1000Base-
SFP
DVS-328R02-8SFP -25 to 70 4 4 20 1 1 3
Optional Products
LCP Series: 100Base-FX/1000Base-X SFP Fiber Transceiver CliQII/PMC Series: 48V
Industrial Power Supply
DC
Combo Port
10/100Base-T(X)
and 100Base-SFP
10/100
Base-T(X)
DI
DO
(Relay)
Power
Input
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
20
Industry
DVS-110 series
Managed Industrial 7-Port FE + 3-Port GbE Combo 100/1000Base-SFP Ethernet Switches
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
IPv6 address suitable for larger network and
neighbor discovery
Automatic IP assignment by DHCP/BootP server
for easy network construction
DHCP relay option 82 for sending DHCP requests
with clients’ identities to a DHCP server
SNMP v1/v2c/v3 facilitates the exchange of
management between network devices
Supports MODBUS TCP protocols that facilitate
the remote management by SCADA and other
industrial devices
STP/RSTP/MSTP for network redundancy further
ensures reliability
QoS (IEEE 802.1p) and TOS/DSCP for mission-
critical applications
IEEE 802.1Q VLAN and GVRP optimize network
strategy
Enhanced network security with IEEE 802.1X,
TACACS+, SSH, HTTPS and SNMP v3
IEEE 802.3ad port trunking in parallel to increase
the link bandwidth
SNTP (simple network time protocol) for network
clock synchronization
Broadcast/Multicast/Unknown Unicast storm
control improves throughput problems
Intelligent Access Control List (ACL)
MAC addresses locking function per port blocks
unauthorized access
USB console interface for easy connection with
laptops
IGMP Snooping and GMVP prunes multicast trafc
RMON groups 1, 2, 3, 9 (history, statistics, alarms
and events) for enhanced ow management and
analysis
CPU utilization displays the amount of work the
CPU handles
Port mirroring for Many-to-One ports online
troubleshooting
Versatile system le updates by TFTP, HTTPS or
HTTP
DDM diagnosis function by SFP ber module
Auto warning by email, DI, relay, Syslog & SNMP
trap
Compatible with various industrial protocols,
including EtherNet/IP, Pronet, CC-LINK IE and
DNP 3.0
Specications
TECHNOLOGY
Standard Compliance
• IEEE 802.3 10Base-T
• IEEE 802.3u 100Base-T(X) and 100Base-FX
• IEEE 802.3ab 1000Base-T
• IEEE 802.3z 1000Base-X
• IEEE 802.3x Flow Control
• IEEE 802.1D Spanning Tree Protocol
• IEEE 802.1w Rapid Spanning Tree Protocol
• IEEE 802.1s Multiple Spanning Tree Protocol
• IEEE 802.1p Class of Service, Priority Protocols
• IEEE 802.1Q VLAN Tagging
• IEEE 802.1X Port Authentication
• IEEE 802.3ad LACP Aggregation
• IEEE 802.1AB Link Layer Discovery Protocol
21
Processing Type
• Store and Forward
IEEE 802.3x ow control in
full duplex, back-pressure ow
control in half duplex
INTERFACE
Industry
Fast Ethernet
RJ45 Ports:
• 10/100Base-T(X), auto MDI/MDI-X, auto negotiation
Gigabit Ethernet Combo Ports
RJ45 Ports:
• 10/100/1000Base-T, auto MDI/MDI-X, auto negotiation
SFP Ports:
• 100/1000Base-SFP
Console Port
• USB B-Type connector
LEDs
Device:
• ALARM, PWR1, PWR2, DI1, DI2
Ports:
• 100/1000M (SFP port), 10/100/1000M (GbE RJ45 port), 10/100M (FE RJ45 port), LINK/
ACT
Digital Inputs (DI)
• 2 sets
• 0~+5V is OFF
• +11V~30V is ON
• Max. input current 6mA
PERFORMANCE AND SCALABILITY
Switching Capacity
• 7.4Gbps, wire-speed, non-blocking switching fabric
Forwarding Rate
• 11Mpps
MAC Address Table
• 8K
Packet Buffer Memory
• 512K bits
IGMP Multicast Groups
• 256
Max. VLANs
• 255
MANAGEMENT
Software
• STP/RSTP/MSTP, LACP, QoS, IGMP Snooping v1/v2/v3, IGMP Query v1/v2, GARP, GMRP, VLAN, SSH, DNS, HTTP, HTTPS, RADIUS, TACACS+, SNMP v1/v2c/v3, SNMP Traps, TFTP, RMON, LLDP, BootP Server/Client, DHCP Server/Client, DHCP L2 Relay, DHCP Relay Option 82, DHCP Option 66/67, Telnet, Syslog, SMTP, SNTP Server/ Client, IPv6, MODBUS TCP
Security
MAC/IP/TCP/UDP ltering, HTTPS, SSH, 802.1X, TACACS+, SNMP v3
Alarm Contacts (DO)
• 2 relay outputs
• Carry current 2A@24V
DC
Reset Button
• 1 set
Quality of Service
• 8 priority queues per port
DHCP/BootP Server
• 1275 IP addresses
Jumbo Frame
• 9,216 Bytes
Conguration
• Web Browser, Cisco-like Telnet CLI, USB Local Console, SNMP, MODBUS TCP, IEXplorer Utility
MIB
• MIB II, Bridge MIB, SNMP MIB, Ether-like MIB, Q-Bridge/P-Bridge MIB, IF MIB, Traceroute MIB, TCP MIB, UDP MIB, IP MIB, RMON Group 1, 2, 3, 9, Delta Private MIB
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
POWER REQUIREMENTS
Input Voltage
• 2 sets, 12 to 48 VDC redundant terminal block input
lnput Current
• Max. 0.95A
PHYSICAL
Housing
• IP40 metal case
Dimensions
• 145.3 mm (H) x 75 mm (W) x 108.7 mm (D)
ENVIRONMENTAL LIMITS
Operating Temperature
• -40℃ to 75℃ (-40˚F to 167˚F)
Overload Current Protection
• Present, max. input current 3A
Reverse Polarity Protection
• Present
Weight
• 564g
Installation
• Industrial DIN-Rail and wall mounting
Storage Temperature
• -40℃ to 85℃ (-40˚F to 185˚F)
22
Buffer Time
• Min. 12ms at 24V
DC
Ambient Relative Humidity
• 5% to 95% (non-condensing)
Industry
APPROVALS
Safety
• UL 508, EN 60950-1, IEC 61131-2
EMI
Ethernet Switches
• FCC 47 CFR Part 15 Subpart B Class A, IEC 61000-6-4, EN 55022(CISPR22)
EMS [IEC 61000-6-2
• IEC 61000-4-2 level 3, IEC 61000-4-3 level 3, IEC 61000-4-4 level 4, IEC 61000-4-5 level 3, IEC 61000-4-6 level 3, IEC 61000-4-8 level 4, IEC 61000-4-29
Ordering Information
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Model Name
DVS-110W02-3SFP -40℃ to 75
Optional Products
LCP Series: 100Base-FX/1000Base-X SFP Fiber Transceiver
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply
Freefall:
• IEC 60068-2-32
Vibration:
• IEC 60068-2-6
Hi-Pot:
• 1.5KV
, EN 55024(CISPR24)]
Environmental Type Tests
Cold Temperature:
• IEC 60068-2-1
Dry Heat:
• IEC 60068-2-2
Humidity:
• IEC 60068-2-30
Shock:
• IEC 60255-21-2
Product Port Combination Interface
Operating
Temperature
Combo Port
10/100/1000Base-T
and 100/1000Base-SFP
3 --- 7 2 2 2
10/100/1000
Base-T
10/100
Base-T(X)
DI
DO
(Relay)
Power
Input
23
DVS-109 series
Managed Industrial 8-Port FE + 1-Port GbE Ethernet Switches
IPv6 address suitable for larger network and
neighbor discovery
Automatic IP assignment by DHCP/BootP server
for easy network construction
DHCP relay option 82 for sending DHCP requests
with clients’ identities to a DHCP server
Port-based DHCP server with IP and MAC binding
makes IP maintenance much easier*
SNMP v1/v2c/v3 facilitates the exchange of
management between network devices
Supports EtherNet/IP and MODBUS TCP
protocols that facilitate the remote management
by SCADA and other industrial devices
Proprietary ONE RING and ONE CHAIN high end
redundancy technology, easy to build multiple
ring topology, self-healing recovery time < 20ms
STP/RSTP/MSTP for network redundancy further
ensures reliability
QoS(IEEE 802.1p) and TOS/DSCP for mission-
critical applications
IEEE 802.1Q VLAN, MAC-based VLAN, IP Subnet-
based VLAN, VLAN isolation and GVRP optimize
network strategy
Enhanced network security with IEEE 802.1X,
TACACS+, SSH, HTTPS and SNMP v3
IEEE 802.3ad port trunking in parallel to increase
the link bandwidth
SNTP (simple network time protocol) for network
clock synchronization
Broadcast/Multicast/Unknown Unicast storm
control improves throughput problems
Loopback-Detection to avoid broadcast loops, and
shutdown the corresponding ports automatically
Cable diagnostic provides the mechanism to detect
and report potential cabling issues
Intelligent Access Control List (ACL)
MAC addresses locking function per port blocks
unauthorized access
USB console interface for easy connection with
laptops
IGMP Snooping and GMVP prunes multicast trafc
RMON groups 1,2,3,9 (history, statistics, alarms
and events) for enhanced ow management and
analysis
CPU utilization displays the amount of work the
CPU handles
Port mirroring for Many-to-One ports online
troubleshooting
Versatile system le updates by TFTP, HTTPS or
HTTP
DDM diagnosis function by SFP ber module
Auto warning by email, DI, relay, Syslog & SNMP
trap
Compatible with various industrial protocols,
including EtherNet/IP, Pronet, CC-LINK IE and
DNP 3.0
*Please check DELTA website for the latest rmware version
Industry
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Specications
TECHNOLOGY
Standard Compliance
• IEEE 802.3 10Base-T
• IEEE 802.3u 100Base-T(X) and 100Base-FX
• IEEE 802.3ab 1000Base-T
• IEEE 802.3x Flow Control
• IEEE 802.1D Spanning Tree Protocol
• IEEE 802.1w Rapid Spanning Tree Protocol
• IEEE 802.1s Multiple Spanning Tree Protocol
• IEEE 802.1p Class of Service, Priority Protocols
• IEEE 802.1Q VLAN Tagging
• IEEE 802.1X Port Authentication
• IEEE 802.3ad LACP Aggregation
24
• IEEE 802.1AB Link Layer Discovery Protocol
Processing Type
• Store and Forward
• IEEE 802.3x Flow control in
full duplex, back-pressure ow
control in half duplex
Industry
INTERFACE
Fast Ethernet
RJ45 Ports:
• 10/100Base-T(X), auto MDI/MDI-X, auto
Ethernet Switches
negotiation
Gigabit Ethernet
RJ45 Ports:
• 10/100/1000Base-T, auto MDI/MDI-X, auto negotiation
Console Port
• USB B-Type connector
PERFORMANCE AND SCALABILITY
Switching Capacity
• 3.6Gbps, Wired speed, Non-blocking
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
switching fabric
Forwarding Rate
• 5.35Mpps
MAC Address Table
• 8K
MANAGEMENT
Software
• STP/RSTP/MSTP, LACP, QoS, IGMP Snooping v1/v2/v3, IGMP Query v1/v2, GARP, GMRP, VLAN, SSH, DNS, HTTP, HTTPS, RADIUS, TACACS+, SNMP v1/v2c/v3, SNMP Traps, TFTP, RMON, LLDP, BootP Server/Client, DHCP Server/Client, DHCP L2 Relay, DHCP Relay Option 82, DHCP Option 66/67, Telnet, Syslog, SMTP, SNTP Server/ Client, IPv6, MODBUS TCP, EtherNet/IP
Security
MAC/IP/TCP/UDP ltering, HTTPS, SSH, 802.1x, TACACS+, SNMP v3
LEDs
Device:
• ALARM, PWR1, PWR2, DI
Ports:
• 10/100/1000M(GbE RJ45 port), 10/100M(FE RJ45 port), LINK/ACT
Digital Inputs (DI)
• 1 set
• 0~+5V is OFF
• +11V~30V is ON
• Max. input current 6mA
Packet Buffer Memory
• 512K bits
IGMP Multicast Groups
• 256
Max. VLANs
• 255
Conguration
• Web Browser, Cisco-like Telnet CLI, USB Local Console, SNMP,
MODBUS TCP, EtherNet/IP, IEXplorer Utility
MIB
• MIB II, Bridge MIB, SNMP MIB, Ether-like MIB, Q-Bridge/P-Bridge MIB, IF MIB, Traceroute MIB, TCP MIB, UDP MIB, IP MIB, RMON Group 1,2,3,9, Delta Private MIB
Alarm Contacts (DO)
• 1 relay output
• Carry current 2A@24V
Reset Button
• 1 set
Quality of Service
• 8 priority queues per port
DHCP/BootP Server
• 1275 IP addresses
Jumbo Frame
• 9,216 Bytes
DC
POWER REQUIREMENTS
Input Voltage
• 2 sets, 12 to 48VDC redundant terminal block input
lnput Current
• Max. 0.58A
PHYSICAL
Housing
• IP40 metal case
Dimensions
• 145.3 mm (H) x 75 mm (W) x 108.7 mm (D)
ENVIRONMENTAL LIMITS
Operating Temperature
• -40℃ to 75℃ (-40˚F to 167˚F)
Overload Current Protection
• Present, max. Input current 3A
Reverse Polarity Protection
• Present
Weight
• 500g
Installation
• Industrial DIN-Rail and wall mounting
Storage Temperature
• -40℃ to 85℃ (-40˚F to 185˚F)
25
Buffer Time
• Min. 12ms at 24V
DC
Ambient Relative Humidity
• 5% to 95% (non-condensing)
APPROVALS
Industry
Safety
• UL 508, EN 60950-1, IEC 61131-2
EMI
• FCC 47 CFR Part 15 Subpart B Class A, IEC 61000-6-4, EN 55022(CISPR22)
EMS [IEC 61000-6-2,
• IEC 61000-4-2 level 3, IEC 61000-4-3 level 3, IEC 61000-4-4 level 4, IEC 61000-4-5 level 3, IEC 61000-4-6 level 3, IEC 61000-4-8 level 4, IEC 61000-4-29
EN 55024(CISPR24)]
Environmental Type Tests
Cold Temperature:
• IEC 60068-2-1
Dry Heat:
• IEC 60068-2-2
Humidity:
• IEC 60068-2-30
Shock:
• IEC 60255-21-2
Ordering Information
Product Port Combination Interface
Model Name
DVS-109W02-1GE -40℃ to 75
Operating
Temperature
Optional Products
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply
Combo Port
10/100/1000Base-T
and 100/1000Base-SFP
--- 1 8 1 1 2
10/100/1000
Base-T
10/100
Base-T(X)
Freefall:
• IEC 60068-2-32
Vibration:
• IEC 60068-2-6
Hi-Pot:
• 1.5KV
DI
(Relay)
DO
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Power
Input
26
Industry
DVS-108 series
Managed Industrial 6-Port FE + 2-Port GbE Combo 100/1000Base-SFP Ethernet Switches
Ethernet Switches
IPv6 address suitable for larger network and
neighbor discovery
Automatic IP assignment by DHCP/BootP server
for easy network construction
DHCP relay option 82 for sending DHCP requests
with clients’ identities to a DHCP server
Port-based DHCP server with IP and MAC binding
makes IP maintenance much easier*
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
SNMP v1/v2c/v3 facilitates the exchange of
management between network devices
Supports EtherNet/IP and MODBUS TCP
protocols that facilitate the remote management
by SCADA and other industrial devices
Proprietary ONE RING and ONE CHAIN high end
redundancy technologies, easy to build multiple
ring topology, self-healing recovery time < 20ms.
STP/RSTP/MSTP for network redundancy further
ensures reliability
QoS (IEEE 802.1p) and TOS/DSCP for mission-
critical applications
IEEE 802.1Q VLAN, MAC-based VLAN*, IP
Subnet-based VLAN*, VLAN isolation* and GVRP
optimize network strategy
Enhanced network security with IEEE 802.1X,
TACACS+, SSH, HTTPS and SNMP v3
IEEE 802.3ad port trunking in parallel to increase
the link bandwidth
SNTP (simple network time protocol) for network
clock synchronization
Broadcast/Multicast/Unknown Unicast storm
control improves throughput problems
Loopback-Detection to avoid broadcast loops, and
shutdown the corresponding ports automatically.
Cable diagnostic provides the mechanism to
detect and report potential cabling issues
Intelligent Access Control List (ACL)
MAC addresses locking function per port blocks
unauthorized access
USB console interface for easy connection with
laptops
IGMP Snooping and GMVP prunes multicast trafc
RMON groups 1,2,3,9 (history, statistics, alarms
and events) for enhanced ow management and
analysis
CPU utilization displays the amount of work the
CPU handles
Port mirroring for Many-to-One ports online
troubleshooting
Versatile system le updates by TFTP, HTTPS or
HTTP
DDM diagnosis function by SFP ber module
Auto warning by email, DI, relay, Syslog & SNMP
trap
Compatible with various industrial protocols,
including EtherNet/IP, Pronet, CC-LINK IE and
DNP 3.0
*Please check DELTA website for the latest rmware version
Specications
TECHNOLOGY
Standard Compliance
• IEEE 802.3 10Base-T
• IEEE 802.3u 100Base-T(X) and 100Base-FX
• IEEE 802.3ab 1000Base-T
• IEEE 802.3z 1000Base-X
• IEEE 802.3x Flow Control
• IEEE 802.1D Spanning Tree Protocol
• IEEE 802.1w Rapid Spanning Tree Protocol
• IEEE 802.1s Multiple Spanning Tree Protocol
• IEEE 802.1p Class of Service, Priority Protocols
• IEEE 802.1Q VLAN Tagging
• IEEE 802.1X Port Authentication
• IEEE 802.3ad LACP Aggregation
27
• IEEE 802.1AB Link Layer Discovery Protocol
Processing Type
• Store and Forward
• IEEE 802.3x Flow control in
full duplex, back-pressure ow
control in half duplex
INTERFACE
Industry
Fast Ethernet
RJ45 Ports:
• 10/100Base-T(X), auto MDI/MDI-X, auto negotiation
Gigabit Ethernet Combo Ports
RJ45 Ports:
• 10/100/1000Base-T, auto MDI/MDI-X, auto negotiation
SFP Ports:
• 100/1000Base-SFP
Console Port
• USB B-Type connector
LEDs
Device:
• ALARM, PWR1, PWR2, DI1, DI2
Ports:
• 100/1000M (SFP port), 10/100/1000M (GbE RJ45 port), 10/100M (FE RJ45 port), LINK/ ACT
Digital Inputs (DI)
• 2 sets
• 0~+5V is OFF
• +11V~30V is ON
• Max. input current 6mA
PERFORMANCE AND SCALABILITY
Switching Capacity
• 5.2Gbps, wire-speed, non-blocking switching fabric
Forwarding Rate
• 7.7Mpps
MAC Address Table
• 8K
Packet Buffer Memory
• 512K bits
IGMP Multicast Groups
• 256
Max. VLANs
• 255
MANAGEMENT
Software
• STP/RSTP/MSTP, LACP, QoS, IGMP Snooping v1/v2/v3, IGMP Query v1/v2, GARP, GMRP, VLAN, SSH, DNS, HTTP, HTTPS, RADIUS, TACACS+, SNMP v1/v2c/v3, SNMP Traps, TFTP, RMON, LLDP, BootP Server/Client, DHCP Server/Client, DHCP L2 Relay, DHCP Relay Option 82, DHCP Option 66/67, Telnet, Syslog, SMTP, SNTP Server/ Client, IPv6, MODBUS TCP, EtherNet/IP
Security
MAC/IP/TCP/UDP ltering, HTTPS, SSH, 802.1X, TACACS+, SNMP v3
Alarm Contacts (DO)
• 2 relay outputs
• Carry current 2A@24V
DC
Reset Button
• 1 set
Quality of Service
• 8 priority queues per port
DHCP/BootP Server
• 1275 IP addresses
Jumbo Frame
• 9,216 Bytes
Conguration
• Web Browser, Cisco-like Telnet CLI, USB Local Console, SNMP, MODBUS TCP, EtherNet/IP, IEXplorer Utility
MIB
• MIB II, Bridge MIB, SNMP MIB, Ether-like MIB, Q-Bridge/P-Bridge MIB, IF MIB, Traceroute MIB, TCP MIB, UDP MIB, IP MIB, RMON Group 1,2,3,9, Delta Private MIB
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
POWER REQUIREMENTS
Input Voltage
• 2 sets, 12 to 48 VDC redundant terminal block input
lnput Current
• Max. 0.87A
PHYSICAL
Housing
• IP40 metal case
Dimensions
• 145.3 mm (H) x 75 mm (W) x 108.7 mm (D)
ENVIRONMENTAL LIMITS
Operating Temperature
• -40℃ to 75℃ (-40˚F to 167˚F)
Overload Current Protection
• Present, max. input current 3A
Reverse Polarity Protection
• Present
Weight
• 520g
Installation
• Industrial DIN-Rail and wall mounting
Storage Temperature
• -40℃ to 85℃ (-40˚F to 185˚F)
28
Buffer Time
• Min. 12ms at 24V
DC
Ambient Relative Humidity
• 5% to 95% (non-condensing)
Industry
APPROVALS
Safety
• UL 508, EN 60950-1, IEC 61131-2
EMI
Ethernet Switches
• FCC 47 CFR Part 15 Subpart B Class A, IEC 61000-6-4, EN 55022(CISPR22)
EMS [IEC 61000-6-2,
• IEC 61000-4-2 level 3, IEC 61000-4-3 level 3, IEC 61000-4-4 level 4, IEC 61000-4-5 level 3, IEC 61000-4-6 level 3, IEC 61000-4-8 level 4, IEC 61000-4-29
Ordering Information
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Model Name
DVS-108W02-2SFP -40℃ to 75
Optional Products
LCP Series: 100Base-FX/1000Base-X SFP Fiber Transceiver
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply
Freefall:
• IEC 60068-2-32
Vibration:
• IEC 60068-2-6
Hi-Pot:
• 1.5KV
EN 55024(CISPR24)]
Environmental Type Tests
Cold Temperature:
• IEC 60068-2-1
Dry Heat:
• IEC 60068-2-2
Humidity:
• IEC 60068-2-30
Shock:
• IEC 60255-21-2
Product Port Combination Interface
Operating
Temperature
Combo Port
10/100/1000Base-T
and 100/1000Base-SFP
2 --- 6 2 2 2
10/100/1000
Base-T
10/100
Base-T(X)
DI
DO
(Relay)
Power
Input
29
DVS-G008I/G005I00A Series
Unmanaged Industrial 5 and 8-Port GbE Ethernet Switches
Supports IEEE 802.1p based QoS for packet forwarding precedence
Built-in Broadcast Storm Protection
Transparent transmission of VLAN tagged packets
Jumbo frame size up to 9,216 Bytes
EEE Green Ethernet for power savings
Compatible with various industrial protocols, including EtherNet/IP,
Pronet, CC-LINK IE and DNP 3.0
Industry
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Specications
TECHNOLOGY
Standard Compliance
• IEEE 802.3 10Base-T
• IEEE 802.3u 100Base-T(X)
• IEEE 802.3ab 1000Base-T
• IEEE 802.3x Flow Control
• IEEE 802.1p Class of Service, Priority Protocols
INTERFACE
Gigabit Ethernet
RJ45 Ports:
• 10/100/1000Base-T, auto MDI/MDI-X, auto negotiation
LEDs
Per Device:
• PWR
Per Port:
• 10/100/1000M, LINK/ACT
PERFORMANCE AND SCALABILITY
Switching Capacity
DVS-G005I00A:
• 10Gbps, wire-speed, non-blocking
switching fabric
DVS-G008I00A:
• 16Gbps, wire-speed, non-blocking
switching fabric
Forwarding Rate
DVS-G005I00A:
• 7.44Mpps
DVS-G008I00A:
• 11.9Mpps
MAC Address Table
DVS-G005I00A:
• 2K
DVS-G008I00A:
• 8K
Packet Buffer Memory
DVS-G005I00A:
• 1M bits
DVS-G008I00A:
• 2M bits
Jumbo Frame
• 9,216 Bytes
Processing Type
• Store and Forward
IEEE 802.3x ow control in full duplex, back-pressure ow control
in half duplex
Broadcast Storm Protection
• Default enabled
Transparent Forwarding VLAN Tagged Packets
• Default enabled
IEEE 802.1p based QoS
• Default enabled
Green Ethernet
• Default enabled
30
Industry
POWER REQUIREMENTS
Input Voltage
• 1 set, 12 to 48 VDC terminal block input
Input Current
Ethernet Switches
• Max. 0.18A
PHYSICAL
Housing
• IP40 metal case
Dimensions
• 145.3mm (H) x 45mm (W) x 108.7mm (D)
ENVIRONMENTAL LIMITS
Operating Temperature
• -10℃ to 60℃(14˚F to 140˚F)
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
APPROVALS
Safety
• UL 508, EN 60950-1, IEC 61131-2
EMI
• FCC 47 CFR Part 15 Subpart B Class A, IEC 61000-6-4, EN 55022(CISPR22)
EMS [IEC 61000-6-2
• IEC 61000-4-2 level 3, IEC 61000-4-3 level 3, IEC 61000-4-4 level 4, IEC 61000-4-5 level 2, IEC 61000-4-6 level 2, IEC 61000-4-8 level 4, IEC 61000-4-29
, EN 55024(CISPR24)]
Overload Current Protection
• Present, max. input current 3A
Reverse Polarity Protection
• Present
Weight
• 300g
Installation
• Industrial DIN-Rail and wall mounting
Storage Temperature
• -40℃ to 85℃(-40℉ to 185℉)
Environmental Type Tests
Cold Temperature:
• IEC 60068-2-1
Dry Heat:
• IEC 60068-2-2
Humidity:
• IEC 60068-2-30
Shock:
• IEC 60255-21-2
Buffer Time
• Min. 13ms at 24V
DC
Ambient Relative Humidity
• 5% to 95% (non-condensing)
Freefall:
• IEC 60068-2-32
Vibration:
• IEC 60068-2-6
Hi-Pot:
• 1.5KV
Ordering Information
Product Port Combination Interface
Model Name
Operating
Temperature
DVS-G008I00A -10℃ to 60℃ --- 8 --- --- --- 1
DVS-G005I00A -10℃ to 60℃ --- 5 --- --- --- 1
Optional Products
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply
Combo Port
10/100/1000Base-T and
100/1000Base-SFP
10/100/1000
Base-T
10/100
Base-T(X)
DI
DO
(Relay)
Power
Input
31
DVS-016 Series
Unmanaged Industrial 16-Port FE Ethernet Switches
Supports IEEE 802.1p based QoS for packet forwarding precedence
Built-in Broadcast Storm Protection
Transparent transmission of VLAN tagged packets
12 to 48 V
Auto warning by relay output for link-down and power failure
Compatible with various industrial protocols, including EtherNet/IP,
Pronet, CC-LINK IE and DNP 3.0
Specications
redundant terminal block power input
DC
Industry
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
TECHNOLOGY
Standard Compliance
• IEEE 802.3 10Base-T
• IEEE 802.3u 100Base-T(X) and 100Base-FX
• IEEE 802.3x Flow Control
• IEEE 802.1p Class of Service, Priority Protocols
INTERFACE
Fast Ethernet
RJ45 Ports:
• 10/100Base-T(X), auto MDI/MDI-X, auto negotiation
Fiber Optic Ports:
• 100Base-FX (SC connector), MultiMode or SingleMode
LEDs
Per Device:
• ALARM, PWR1, PWR2
Per Port:
100M (RJ45 port), 100M (ber port), LINK/
ACT
PERFORMANCE AND SCALABILITY
Switching Capacity
• 3.2Gbps, wire-speed, non-blocking switching fabric
Forwarding Rate
• 4.8Mpps
MAC Address Table
• 8K
Packet Buffer Memory
• 1M bits
Broadcast Storm Protection
• Default enabled
POWER REQUIREMENTS
Input Voltage
• 2 sets, 12 to 48 VDC redundant terminal block input
Input Current
• Max. 0.6A
Overload Current Protection
• Present, max. input current 3A
Processing Type
• Store and Forward
IEEE 802.3x ow control in full duplex,
back-pressure ow control in half duplex
DIP Switches
Port link-down alarm conguration
Alarm Contacts (DO)
• 1 relay output
• Carry current 2A@24V
Transparent Forwarding VLAN Tagged Packets
• Default enabled
IEEE 802.1p based QoS
• Default enabled
Reverse Polarity Protection
• Present
Buffer Time
• Min. 13ms at 24V
DC
DC
PHYSICAL
Housing
• IP40 metal case
Dimensions
• 145.3mm (H) x 75mm (W) x 108.7mm (D)
Weight
• 490g
Installation
• Industrial DIN-Rail and wall mounting
32
Industry
ENVIRONMENTAL LIMITS
Operating Temperature
• -40℃ to 75℃(-40˚F to 167˚F)
Storage Temperature
• 40℃ to 85℃(-40˚F to 185˚F)
Ambient Relative Humidity
• 5% to 95% (non-condensing)
Ethernet Switches
APPROVALS
Safety
• UL 508, EN 60950-1, IEC 61131-2
EMI
• FCC 47 CFR Part 15 Subpart B Class B, IEC 61000-6-4, EN 55022(CISPR22)
EMS [IEC 61000-6-2
• IEC 61000-4-2 level 3, IEC 61000-4-3 level 3, IEC 61000-4-4 level 4, IEC 61000-4-5 level 3, IEC 61000-4-6 level 3, IEC 61000-4-8 level 4, IEC 61000-4-29
Fiber Optics
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Cable
Wavelength
Max. TX Power
Min. TX Power
RX Sensitivity
Optical Budget
Max. Link Distance
(1) 62.5/125μm ber optic cable (2) 50/125μm ber optic cable
, EN 55024(CISPR24)]
MultiMode SingleMode
62.5/125μm, 50/125μm 9/125μm
1310nm 1310nm
-14dBm -8dBm
-20dBm(1)
-22.5dBm(2)
-31dBm -31dBm
11dBm(1)
8.5dBm(2)
5km 30km
Environmental Type Tests
Cold Temperature:
• IEC 60068-2-1
Dry Heat:
• IEC 60068-2-2
Humidity:
• IEC 60068-2-30
Shock:
• IEC 60255-21-2
100Base-FX
-15dBm
16dBm
Freefall:
• IEC 60068-2-32
Vibration:
• IEC 60068-2-6
Hi-Pot:
• 1.5KV
Note:
The actual link distance of a
particular fiber optic link depends on the
optical budget, the number of connectors
and splices, and cabling quantity. Please
measure and verify the actual link loss
values once the link is established to
identify any potential performance issues.
Ordering Information
Product Port Combination Interface
Model Name
DVS-016W01 -40℃ to 75
DVS-016W01-MC01 -40℃ to 75
DVS-016W01-SC01 -40℃ to 75
Operating
Temperature
Optional Products
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply
10/100
Base-T(X)
16 --- --- --- 1 2
15 1 --- --- 1 2
15 --- 1 --- 1 2
100Base-FX
SC Connector,
MultiMode, 5km
33
SC Connector,
SingleMode, 30km
DI
DO
(Relay)
Power
Input
DVS-008 Series
Unmanaged Industrial 8-Port FE Ethernet Switches
Supports IEEE 802.1p based QoS for packet forwarding precedence
Built-in Broadcast Storm Protection
Transparent transmission of VLAN tagged packets
12 to 48 V
Auto warning by relay output for link-down and power failure
Compatible with various industrial protocols, including EtherNet/IP,
Pronet, CC-LINK IE and DNP 3.0
redundant terminal block power input
DC
Industry
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Specications
TECHNOLOGY
Standard Compliance
• IEEE 802.3 10Base-T
• IEEE 802.3u 100Base-T(X) and 100Base-FX
• IEEE 802.3x Flow Control
• IEEE 802.1p Class of Service, Priority Protocols
INTERFACE
Fast Ethernet
RJ45 Ports:
• 10/100Base-T(X), auto MDI/MDI-X, auto negotiation
Fiber Optic Ports:
• 100Base-FX(SC connector), MultiMode or SingleMode
LEDs
Per Device:
• ALARM, PWR1, PWR2
Per Port:
100M(RJ45 port), 100M(ber port), LINK/ACT
DIP Switches
Port link-down alarm conguration
PERFORMANCE AND SCALABILITY
Switching Capacity
• 1.6Gbps, wire-speed, non-blocking switching fabric
Forwarding Rate
• 2.4Mpps
MAC Address Table
• 8K
Packet Buffer Memory
• 1M bits
Broadcast Storm Protection
• Default enabled (DVS-008W series)
Processing Type
• Store and Forward
IEEE 802.3x ow control in full duplex,
back-pressure ow control in half duplex
Alarm Contacts (DO)
• 1 relay output
• Carry current 2A@24V
DC
Transparent Forwarding VLAN Tagged Packets
• Default enabled (DVS-008W series)
IEEE 802.1p based QoS
• Default enabled (DVS-008W series)
POWER REQUIREMENTS
Input Voltage
DVS-008W series:
• 2 sets, 12 to 48 VDC redundant terminal block input
DVS-008I00:
• 1 set, 12 to 48 VDC terminal block input
Input Current
DVS-008W series:
• Max. 0.45A
DVS-008I00:
• Max. 0.18A
Overload Current Protection
• Present, max. input current 3A
34
Reverse Polarity Protection
• Present
Buffer Time
DVS-008W series:
• Min. 13ms at 24VDC
DVS-008I:
• Min. 10ms at 24V
DC
Industry
PHYSICAL
Housing
• IP40 metal case
Dimensions
DVS-008W series:
• 145.3 mm (H) x 75 mm (W) x 108.7 mm (D)
DVS-008I00:
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
• 145.3 mm (H) x 45 mm (W) x 108.7 mm (D)
ENVIRONMENTAL LIMITS
Operating Temperature
DVS-008W series:
• -40℃ to 75℃ (-40˚F to 167˚F)
DVS-008I00:
• -10℃ to 60℃ (14˚F to 140˚F)
• Tested @ -25℃ to 70℃(-13˚F to 158˚F)
APPROVALS
Safety
• UL 508, EN 60950-1, IEC 61131-2
EMI
• FCC 47 CFR Part 15 Subpart B Class B, IEC 61000-6-4, EN 55022(CISPR22),
EMS [IEC 61000-6-2
• IEC 61000-4-2 level 3, IEC 61000-4-3 level 3, IEC 61000-4-4 level 4, IEC 61000-4-5 level 3, IEC 61000-4-6 level 3, IEC 61000-4-8 level 4, IEC 61000-4-29
, EN 55024(CISPR24)]
Weight
DVS-008W series:
• 430g
DVS-008I00:
• 300g
Installation
• Industrial DIN-Rail and wall mounting
Storage Temperature
• -40℃ to 85℃ (-40˚F to 185˚F)
Ambient Relative Humidity
• 5% to 95% (non-condensing)
Environmental Type Tests
Cold Temperature:
• IEC 60068-2-1
Dry Heat:
• IEC 60068-2-2
Humidity:
• IEC 60068-2-30
Shock:
• IEC 60255-21-2
Freefall:
• IEC 60068-2-32
Vibration:
• IEC 60068-2-6
Hi-Pot:
• 1.5KV
Fiber optics
100Base-FX
MultiMode SingleMode
Cable
Wavelength
Max. TX Power
Min. TX Power
RX Sensitivity
Optical Budget
Max. Link Distance
(1) 62.5/125μm ber optic cable (2) 50/125μm ber optic cable
62.5/125μm, 50/125μm 9/125μm
1310nm 1310nm
-14dBm -8dBm
-20dBm(1)
-22.5dBm(2)
-31dBm -31dBm
11dBm(1)
8.5dBm(2)
5km 30km
-15dBm
16dBm
Note: The actual link distance of a
particular ber optic link depends on the
optical budget, the number of connectors
and splices, and cabling quantity. Please
measure and verify the actual link loss
values once the link is established to
identify any potential performance issues.
Ordering Information
Product Port Combination Interface
100Base-FX
SC Connector,
SingleMode, 30km
DI
DO
(Relay)
Model Name
Operating
Temperature
10/100
Base-T(X)
SC Connector,
MultiMode, 5km
DVS-008I00 -10℃ to 60℃ 8 --- --- --- --- 1
DVS-008W01 -40℃ to 75℃ 8 --- --- --- 1 2
DVS-008W01-MC01 -40℃ to 75℃ 7 1 --- --- 1 2
DVS-008W01-MC02 -40℃ to 75℃ 6 2 --- --- 1 2
DVS-008W01-SC01 -40℃ to 75
DVS-008W01-SC02 -40℃ to 75
7 --- 1 --- 1 2
6 --- 2 --- 1 2
Optional Products
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply
Power
Input
35
DVS-005 Series
Unmanaged Industrial 5-Port FE Ethernet Switches
12 to 48 VDC redundant terminal block power input
Auto warning by relay output for link-down and power failure
Compatible with various industrial protocols, including EtherNet/IP,
Pronet, CC-LINK IE, and DNP 3.0
Industry
Ethernet Switches
Specications
TECHNOLOGY
Standard Compliance
• IEEE 802.3 10Base-T
• IEEE 802.3u 100Base-T(X) and 100Base-FX
• IEEE 802.3x Flow Control
Processing Type
• Store and forward
IEEE 802.3x ow control in full duplex, back-pressure ow control in half duplex
INTERFACE
Fast Ethernet
RJ45 Ports:
• 10/100Base-T(X), auto MDI/MDI-X, auto negotiation
Fiber Optic Ports:
• 100Base-FX (SC connector), MultiMode or SingleMode
LEDs
Per Device:
• ALARM, PWR1, PWR2
Per Port:
100M (RJ45 port), 100M (ber port),
LINK/ACT
PERFORMANCE AND SCALABILITY
Switching Capacity
• 1Gbps, wire-speed, non-blocking switching fabric
Forwarding Rate
• 1.5Mpps
MAC Address Table
• 1K
Packet Buffer Memory
• 512K bits
POWER REQUIREMENTS
Input Voltage
DVS-005W series:
• 2 sets, 12 to 48 VDC redundant terminal block power input
DVS-005I00:
• 1 set, 12 to 48 VDC terminal block input
Input Current
• Max. 0.24A
Overload Current Protection
• Present, max. input current 3A
DIP Switches
Port link-down alarm conguration
Alarm Contacts (DO)
• 1 relay output
• Carry current 2A@24V
Reverse Polarity Protection
• Present
Buffer Time
• Min. 13ms at 24V
DC
DC
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
PHYSICAL
Housing
• IP40 metal case
Dimensions
• 145.3mm (H) x 45mm (W) x 108.7mm (D)
Weight
• 300g
Installation
• Industrial DIN-Rail and wall mounting
36
Industry
ENVIRONMENTAL LIMITS
Operating Temperature
DVS-005W series:
• -40℃ to 75℃(-40˚F to 167˚F)
DVS-005I00:
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
• -10℃ to 60℃(14˚F to 140˚F)
• Tested @ -25℃ to 70℃(-13˚F to 158˚F)
APPROVALS
Safety
• UL 508, EN 60950-1, IEC 61131-2
EMI
• FCC 47 CFR Part 15 Subpart B Class B, IEC 61000-6-4, EN 55022(CISPR22),
EMS [IEC 61000-6-2
• IEC 61000-4-2 level 3, IEC 61000-4-3 level 3, IEC 61000-4-4 level 4, IEC 61000-4-5 level 3, IEC 61000-4-6 level 3, IEC 61000-4-8 level 4, IEC 61000-4-29
, EN 55024(CISPR24)]
Storage Temperature
• -40℃ to 85℃(-40˚F to 185˚F)
Environmental Type Tests
Cold Temperature:
• IEC 60068-2-1
Dry Heat:
• IEC 60068-2-2
Ambient Relative Humidity
• 5% to 95% (non-condensing)
Humidity:
• IEC 60068-2-30
Shock:
• IEC 60255-21-2
Freefall:
• IEC 60068-2-32
Vibration:
• IEC 60068-2-6
Hi-Pot:
• 1.5KV
Fiber optics
100Base-FX
MultiMode SingleMode
Cable
Wavelength
Max. TX Power
Min. TX Power
RX Sensitivity
Optical Budget
Max. Link Distance
(1) 62.5/125μm ber optic cable (2) 50/125μm ber optic cable
62.5/125μm, 50/125μm 9/125μm
1310nm 1310nm
-14dBm -8dBm
-20dBm(1)
-22.5dBm(2)
-31dBm -31dBm
11dBm(1)
8.5dBm(2)
5km 30km
Ordering Information
Product Port Combination Interface
Model Name
Operating
Temperature
DVS-005I00 -10℃ to 60
10/100
Base-T(X)
5 --- --- --- --- 1
-15dBm
16dBm
100Base-FX
SC Connector,
MultiMode, 5km
Note: The actual link distance of a
particular ber optic link depends on the
optical budget, the number of connectors
and splices, and cabling quantity. Please
measure and verify the actual link loss
values once the link is established to
identify any potential performance issues.
SC Connector,
DI
SingleMode, 30km
DO
(Relay)
Power
Input
DVS-005W01 -40℃ to 75℃ 5 --- --- --- 1 2
DVS-005W01-MC01 -40℃ to 75℃ 4 1 --- --- 1 2
DVS-005W01-SC01 -40℃ to 75
4 --- 1 --- 1 2
Optional Products
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply
37
DVS-G512W01-4GF Series
IEEE 802.3 af/at PoE+ Managed Industrial 8-Port GbE (PSE) + 4-Port 100/1000Base-SFP Ethernet Switches
Industry
3
Based on IEEE 802.3at standard up to 30Watts per port.
Backwardcompatible with IEEE 802.3af
Advanced PoE managment and intelligent powered device (PD) class detection
IPv6 address suitable for larger network and neighbor discovery
Automatic IP assignment by DHCP server for easy network construction
DHCP relay option 82 for sending DHCP requests with clients’ identities to a DHCP server
SNMP v1/v2c/v3 facilitates real-time remote management of network devices
Proprietary redundancy RING and redundancy CHAIN high end redundancy technologies,
for multiple ring topology. Self-healing recovery time < 30ms
IEC 62439-2 MRP (media redundancy protocol) for IEC-based redundant ring topology
STP/RSTP/MSTP for network redundancy further ensures reliability
QoS (IEEE 802.1p) and TOS/DSCP for mission-critical applications
IEEE 802.1Q VLAN, Q-in-Q double VLAN, VLAN isolation and GVRP optimize network strategy
Enhanced network security with IEEE 802.1X, TACACS+, SSH, HTTPS and SNMP v3
IEEE 802.3ad port trunking in parallel to increase the link bandwidth
IEEE 1588v2 PTP (Precision Time Protocol) for precise time synchronization of network
Broadcast/multicast/unknown unicast Unicast storm control improves throughput problems
Loopback-detection to avoid broadcast loops, and shutdown the corresponding ports automatically
Cable diagnostic provides the mechanism to detect and report potential cabling issues
Intelligent Access Control List (ACL)
MAC addresses ltering function per port blocks unauthorized access
IGMP snooping prunes multicast trafc
Port mirroring for Many-to-One ports online troubleshooting
DDM snooping function by SFP ber module
Auto warning by email, relay, Syslog & SNMP trap
Compatible with various industrial protocols, including EtherNet/IP, Pronet, CC-LINK IE and DNP 3.0
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Specications
TECHNOLOGY
Standard Compliance
• IEEE 802.3 10Base-T
• IEEE 802.3u 100Base-T(X) and 100Base-FX
• IEEE 802.3ab 1000Base-T
• IEEE 802.3z 1000Base-X
• IEEE 802.3x Flow Control
• IEEE 802.1D Spanning Tree Protocol
• IEEE 802.1w Rapid Spanning Tree Protocol
• IEEE 802.1s Multiple Spanning Tree Protocol
• IEEE 802.1p Class of Service, Priority Protocols
• IEEE 802.1Q VLAN Tagging
38
Industry
TECHNOLOGY
Standard Compliance
• IEEE 802.1X Port Authentication
• IEEE 802.3ad LACP Aggregation
• IEEE 802.1AB Link Layer Discovery Protocol
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
• IEEE 1588v2 Clock Synchronization
• IEEE 802.3af PoE 15.4 Watts
• IEEE 802.3at PoE 30 Watts
INTERFACE
Gigabit Ethernet
RJ45 Ports:
• 8 10/100/1000Base-T, auto MDI/MDI-X, auto negotiation
SFP Ports:
• 4 100/1000Base-SFP
PoE+ Pinout:
• 1 & 2 DC +, 3 & 6 DC -
Console Port:
• RS-232 in RJ45 connector
Processing Type
• Store and Forward
IEEE 802.3x Flow control in full duplex, back-pressure ow control in half duplex
LEDs
Device:
• STATUS, PWR1, PWR2, R.M, RING, ALARM
Ports:
• 100/1000M (SFP port), 10/100/1000M (RJ45 port), PoE+
Alarm Contacts(DO)
• 1 relay output
• Carry current 1 A@24V
Reset Button
• 1 set
DC
PERFORMANCE AND SCALABILITY
Switching Capacity
• 24Gbps, Wired speed, Non-blocking switching fabric
Forwarding Rate
• 35.7Mpps
MAC Address Table
• 8K
Packet Buffer Memory
• 4M bits
IGMP Multicast Groups
• 256
Max. VLANs
• 4096
MANAGEMENT
Software
• STP/RSTP/MSTP, LACP, QoS, IGMP Snooping v1/ v2/v3, IGMP Query v1/v2, VLAN, SSH, DNS, HTTP, HTTPS, RADIUS, TACACS+, SNMP v1/v2c/v3, SNMP Traps, TFTP, RMON, LLDP, DHCP Server/Client, DHCP Relay Option 82, Telnet, Syslog, SMTP, SNTP Client, DOS/DDOS auto prevention, MRP, MODBUS TCP
Security
MAC/IP/TCP/UDP ltering, HTTPS, SSH, 802.1x, TACACS+, SNMP v3
Conguration
• Web Browser, Cisco-like Telnet CLI , RJ45 console, SNMP
MIB
• MIB II, Bridge MIB, SNMP MIB, Ether-like MIB, Q-Bridge/P-Bridge MIB, IF
• MIB, Traceroute MIB, TCP MIB, UDP MIB, IP MIB, RMON Group 1,2,3,9,
Delta Private MIB
POWER REQUIREMENTS
Input Voltage
• 2 sets, 48 to 57 VDC redundant terminal block input
Input Current
• Max. 5.5A (with powered device); Max. 0.26A (without powered device)
Quality of Service
• 8 priority queues per port
DHCP Server
• 253 IP addresses
Jumbo Frame
• 9,216 Bytes
Overload Current Protection
• Present, max. input current 10A
Reverse Polarity Protection
• NOT Present
PHYSICAL
Housing
• IP30 metal case
Dimensions
• 154 mm (H) x 96.4 mm (W) x 105.5 mm (D)
Weight
• 1205 g
Installation
• DIN-Rail and wall mounting
39
ENVIRONMENTAL LIMITS
Operating Temperature
• -40℃ to 70℃(-40˚F to 158˚F)
Storage Temperature
• -40℃ to 85℃(-40˚F to 185˚F)
Industry
Ambient Relative Humidity
• 5% to 95% (non-condensing)
APPROVALS
Safety
• EN 60950-1
EMI
• FCC 47 CFR Part 15 Subpart B Class A, EN 55022 (CISPR 22)
EMS(EN55024)
• IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11
Environmental Type Tests
Shock:
• IEC 60068-2-27
Freefall:
• IEC 60068-2-32
Vibration:
• IEC 60068-2-6
Hi-Pot:
• 1.5KV
Ordering Information
Product Port Combination Interface
Model Name
DVS-G512W01-4GF -40℃ to 70
Operating
Temperature
Optional Products
LCP Series: 100Base-FX/1000Base-X SFP Fiber Transceiver CliQII/PMC Series: 48 VDC Industrial Power Supply
af/at PoE+,
10/100/1000
Base-T
8 4 --- 1 2
100/1000
Base-SFP
DI
DO
(Relay)
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Power
Input
40
Industry
DVS-G408W01 Series
IEEE 802.3af/at PoE+ Unmanaged Industrial 8-Port GbE Ethernet Switches
Ethernet Switches
8 10/100/1000Base-T PoE+(PSE) ports
Based on IEEE 802.3at standard up to 30Watts per port. Backward
compatible with IEEE 802.3af
Jumbo frame size up to 9,216 Bytes
48 to 57V
Auto warning by relay output for power failure
Compatible with various industrial protocols of EtherNet/IP, Pronet,
CC-LINK IE and DNP 3.0
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Specications
TECHNOLOGY
Standard Compliance
• IEEE 802.3 10Base-T
• IEEE 802.3u 100Base-T(X)
• IEEE 802.3z 1000Base-X
• IEEE 802.3x Flow Control
• IEEE 802.3af PoE 15.4 Watts
• IEEE 802.3at PoE 30 Watt
3
redundant terminal block power input
DC
Processing Type
• Store and Forward
IEEE 802.3x Flow control in full duplex, back-pressure ow
control in half duplex
INTERFACE
Gigabit Ethernet
RJ45 Ports:
• 10/100/1000Base-T, auto MDI/MDI-X, auto negotiation
PoE+ Pinout:
• 1 & 2 DC+, 3 & 6 DC-
LEDs
Per Device:
• PWR1, PWR2, ALARM
Per Port:
• PoE, 10/100/1000M, LINK/ACT
PERFORMANCE AND SCALABILITY
Switching Capacity
• 16Gbps, wire-speed, non-blocking switching fabric
Forwarding Rate
• 11.9Mpps
MAC Address Table
• 2K
Packet Buffer Memory
• 1.5M bits
Jumbo Frame
• 9,216 Bytes
41
DIP Switches
• Power failure alarm
Alarm Contacts (DO)
• 1 relay output
• Carry current 1A@24V
DC
POWER REQUIREMENTS
Industry
Input Voltage
• 2 sets, 48 to 57 VDC redundant terminal block input
Input Current
• Max. 5A (with powered device); Max. 0.16A (without powered device)
Overload Current Protection
• Present, max. input current 10A
Reverse Polarity Protection
• NOT Present
PHYSICAL
Housing
• IP30 metal case
Dimensions
• 144.3 mm (H) x 26.1 mm (W) x 94.9 mm (D)
Weight
• 390g
Installation
• Industrial DIN-Rail and wall mounting
ENVIRONMENTAL LIMITS
Operating Temperature
• -40℃ to 70℃(-40˚F to 158˚F)
Storage Temperature
• -40℃ to 85℃(-40˚F to 185˚F)
Ambient Relative Humidity
• 5% to 95% (non-condensing)
APPROVALS
Safety
• EN 60950-1
EMI
• FCC 47 CFR Part 15 Subpart B Class A, EN 55022 (CISPR22)
EMS
• IEC 61000-4-2 level 3, EN 61000-4-3 level 3, IEC 61000-4-4 level 3, IEC 61000-4-5 level 3, IEC 61000-4-6 level 3
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Ordering Information
Product Port Combination Interface
Model Name
DVS-G408W01 -40℃ to 70℃ 8 --- --- 1 2
Optional Products
CliQII/PMC Series: 48 VDC Industrial Power Supplies
Operating
Temperature
10/100/1000Base-T
af/at PoE+,
100/
1000Base-SFP
DI
DO
(Relay)
Power
Input
42
Industry
DVS-G406W01-2GF Series
IEEE 802.3af/at PoE+ Unmanaged Industrial 4-Port GbE + 2-Port 100/1000Base-SFP Ethernet Switches
Ethernet Switches
4 10/100/1000Base-T PoE+(PSE) ports
Based on IEEE 802.3at standard up to 30Watts per port.
Backward compatible with IEEE 802.3af
SFP ports support 100Base-FX and 1000Base-X dual transmission speed
Jumbo frame size up to 9K Bytes
48 to 57V
Auto warning by relay output for power failure
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Compatible with various industrial protocols of EtherNet/IP, Pronet,
CC-LINK IE and DNP 3.0
Specications
TECHNOLOGY
Standard Compliance
• IEEE 802.3 10Base-T
• IEEE 802.3u 100Base-T(X) and 100Base-FX
• IEEE 802.3ab 1000Base-T
• IEEE 802.3z 1000Base-X
• IEEE 802.3x Flow Control
• IEEE 802.3af PoE 15.4 Watts
• IEEE 802.3at PoE 30 Watts
3
redundant terminal block power input
DC
Processing Type
• Store and Forward
IEEE 802.3x Flow control in full duplex, back-pressure ow
control in half duplex
INTERFACE
Gigabit Ethernet
RJ45 Ports:
• 10/100/1000Base-T, auto MDI/MDI-X, auto negotiation
PoE+ Pinout:
• 1 & 2 DC+, 3 & 6 DC-
SFP Ports:
• 100/1000Base-SFP
LEDs
Per Device:
• PWR1, PWR2, ALARM
Per Port:
• PoE, 10/100/1000M, LINK/ACT
PERFORMANCE AND SCALABILITY
Switching Capacity
• 12Gbps, wire-speed, non-blocking switching fabric
Forwarding Rate
• 8.9Mpps
MAC Address Table
• 1K
Packet Buffer Memory
• 1M bits
Jumbo Frame
• 9,216 Bytes
43
DIP Switches
• Power failure alarm
• SFP speed
Alarm Contacts (DO)
• 1 relay output
• Carry current 1A@24V
DC
POWER REQUIREMENTS
Industry
Input Voltage
• 2 sets, 48 to 57 VDC redundant terminal block input
Input Current
• Max. 2.52A (with powered device); Max. 0.13A (without powered device)
Overload Current Protection
• Present, max. input current 10A
Reverse Polarity Protection
• NOT Present
PHYSICAL
Housing
• IP30 metal case
Dimensions
• 144.3 mm (H) x 26.1 mm (W) x 94.9 mm (D)
Weight
• 410g
Installation
• Industrial DIN-Rail and wall mounting
ENVIRONMENTAL LIMITS
Operating Temperature
• -40℃ to 70℃(-40˚F to 158˚F)
Storage Temperature
• -40℃ to 85℃(-40℉ to 185℉)
APPROVALS
Safety
• EN 60950-1
EMI
• FCC 47 CFR Part 15 Subpart B Class A, EN 55022 (CISPR22)
EMS
• IEC 61000-4-2 level 3, IEC 61000-4-3 level 3, IEC 61000-4-5 level 3, IEC 61000-4-6 level 3
Ethernet Switches
Ambient Relative Humidity
• 5% to 95% (non-condensing)
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Ordering Information
Product Port Combination Interface
Model Name
DVS-G406W01-2GF -40℃ to 70℃ 4 2 --- 1 2
Operating
Temperature
Optional Products
LCP Series: 100Base-FX/1000Base-X SFP Fiber Transceiver CliQII/PMC Series: 48 VDC Industrial Power Supplies
af/at PoE+,
10/100/1000Base-T
100/
1000Base-SFP
DI
DO
(Relay)
Power
Input
44
Industry
DVS-G402R00-INJ Series
2 10/100/1000Base-T Industrial IEEE 802.3af/at PoE+ Injectors
Ethernet Switches
3
Based on IEEE 802.3at standard up to 30Watts per port.
Backward compatible with IEEE 802.3af
Dual 10/100/1000Base-T for PoE+ OUT and DATA IN
Intelligent PoE+ overvoltage input protection
Reverse polarity and overload current protection
Built-in 24V
Dual power outputs design to supply more devices
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Specications
TECHNOLOGY
Standard Compliance
• IEEE 802.3 10Base-T
• IEEE 802.3u 100Base-T(X)
• IEEE 802.3ab 1000Base-T
• IEEE 802.3af PoE 15.4 Watts
• IEEE 802.3at PoE 30 Watts
power booster for exible PoE deployment
DC
INTERFACE
Gigabit Ethernet
RJ45 Ports:
• 2 10/100/1000Base-T PoE+ OUT, 2 10/100/1000Base-T DATA IN, auto MDI/MDI-X, auto negotiation
PoE+ Pinout:
• 1 & 2 DC +, 3 & 6 DC -
POWER REQUIREMENTS
Input Voltage
• 2 sets, 12 to 57 VDC redundant terminal block input
Input Current
• Max. 5.5A (with powered device)
LEDs
Device:
• PWR
Port:
• PoE+
PoE+ Output Power
• Max. 600mA @ 50 VDC, 30 watts per port
Overload Current Protection
• Present, max. input current 10A
Reverse Polarity Protection
• Present
45
PHYSICAL
Industry
Housing
• IP30 metal case
Dimensions
• 95 mm(H) x 41 mm(W) x 70 mm (D)
Weight
• 370g
Installation
• DIN-Rail and wall mounting
ENVIRONMENTAL LIMITS
Operating Temperature
• -20℃ to 70℃(-4˚F to 158˚F)
Storage Temperature
• -40℃ to 85℃(-40˚F to 185˚F)
Ambient Relative Humidity
• 5% to 95% (non-condensing)
APPROVALS
Safety
• EN 60950-1
EMI
• FCC 47 CFR Part 15 Subpart B Class A, EN 55022 (CISPR22)
EMS
• IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11
Environmental Type Tests
Shock:
• IEC 60068-2-27
Freefall:
• IEC 60068-2-32
Vibration:
• IEC 60068-2-6
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Ordering Information
Product Port Combination Interface
Model Name
DVS-G402R00-INJ -20℃ to 70℃ 2 2 --- --- 2
Operating
Temperature
Optional Products
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply CliQII/PMC Series: 48 VDC Industrial Power Supply
af/at PoE+,
10/100/1000Base-T
10/100/1000Base-T DI
(Relay)
DO
Power
Input
46
Industry
DVS-G401R00-SPL Series
1 10/100/1000Base-T Industrial IEEE 802.3af/at PoE+ Splitters
Ethernet Switches
3
Based on IEEE 802.3at standard up to 30Watts per port.
Backward compatible with IEEE 802.3af
10/100/1000Base-T for PoE+ IN and DATA OUT
Intelligent PoE input overvoltage protection
Reverse polarity and port isolation protection
Power output up to 27 watts
Dual power outputs design to supply more devices
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Specications
TECHNOLOGY
Standard Compliance
• IEEE 802.3 10Base-T
• IEEE 802.3u 100Base-T(X)
• IEEE 802.3ab 1000Base-T
• IEEE 802.3af PoE 15.4 Watts
• IEEE 802.3at PoE 30 Watts
INTERFACE
Gigabit Ethernet
RJ45 Ports:
• 1 10/100/1000Base-T PoE+ IN, 1 10/100/1000Base-T DATA OUT, auto MDI/MDI-X, auto negotiation
PoE+ Pinout:
• PD auto negotiation (1 & 2 DC +, 3 & 6 DC- or 4 & 5 DC +, 7 & 8 DC-)
POWER REQUIREMENTS
PoE+ Input Voltage
• 36 to 57 V
Output Voltage
• 2 sets, 24 V
DC
DC
redundant terminal block
LEDs
Device:
• PWR
Output Current
• Max. 1.125A
Overload Current Protection
• Present, adjust by PoE power classes
Reverse Polarity Protection
• Present
47
PHYSICAL
Industry
Housing
• IP30 metal case
Dimensions
• 95 mm(H) x 26.1 mm(W) x 70 mm (D)
Weight
• 250g
Installation
• DIN-Rail and wall mounting
ENVIRONMENTAL LIMITS
Operating Temperature
• -20℃ to 70℃(-4˚F to 158˚F)
Storage Temperature
• -40℃ to 85℃(-40˚F to 185˚F)
Ambient Relative Humidity
• 5% to 95% (non-condensing)
APPROVALS
Safety
• EN 60950-1
EMI
• FCC 47 CFR Part 15 Subpart B Class A, EN 55022 (CISPR22)
EMS (EN 55024)
• IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11
Environmental Type Tests
Shock:
• IEC 60068-2-27
Freefall:
• IEC 60068-2-32
Vibration:
• IEC 60068-2-6
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Ordering Information
Product Port Combination Interface
Model Name
DVS-G401R00-SPL -20℃ to 70℃ 1 1 --- --- 2
Operating
Temperature
af/at PoE+,
10/100/1000Base-T
10/100/1000Base-T DI
DO
(Relay)
Power
Output
48
Industry
LCP-GbE Series
1-Port Gigabit Ethernet SFP Fiber Transceivers
Ethernet Switches
Compliant with IEEE 802.3z
Full duplex operation
Supports IEEE 802.3x ow control
DDM diagnosis function enhances transmission quality
Duplex LC connector interface
Hot-Pluggable for maximum exibility
TTL signal detection indicator
Class 1 laser product (Compliant with IEC 60825-1 and IEC 60825-2)
Metal case for better EMI immunity
Wide operating temperature
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Specications
TECHNOLOGY
Standard Compliance
• IEEE 802.3z 1000Base-X
INTERFACE
Gigabit Ethernet
• Port number: 1
• Connectors: Duplex LC
Digital Diagnostics Monitoring Function (DDM)
Basic Information
• Ethernet Compliance Code, Vendor Name, Wavelength, Distance
Note1: All Enhanced Parameters listed above include alarm and warning thresholds
Note2: DDM function is fully compatible with Delta DVS series Industrial Ethernet Switches
Enhanced Parameters
• Temperature, Supply Voltage, Transmitted Bias Current, Transmitted Power, Received Power
Fiber Optics
1000Base-X
LCP-1250A4FDR LCP-1250B4QDR  LCP-1250B4MDR
Cable
Wavelength
Max. TX Power
Min. TX Power
RX Sensitivity
Optical Budget
50/125μm MultiMode 9/125μm SingleMode
850nm 1310nm
-4dBm -3dBm
-9.5dBm -9.5dBm
-17dBm -20dBm
7.5dBm 10.5dBm
9/125μm SingleMode
1310nm
1dBm
-4dBm
-23dBm
19dBm
49
PHYSICAL
Housing
• Metal case
Dimensions
• 8.5 mm (H) x 13.4 mm (W) x 57 mm (D)
Industry
Installation
• Hot-swappable, pluggable
ENVIRONMENTAL LIMITS
Operating Temperature
Standard Models:
• -5℃ to 70℃(23˚F to 158˚F)
Wide Temp. Models:
• -40℃ to 85℃ (-40˚F to 185˚F)
Storage Temperature
• -40℃ to 85℃(-40˚F to 185˚F )
Ambient Relative Humidity
• 5% to 95% (non-condensing)
APPROVALS
Safety
• UL 60950-1, EN 60950-1
Laser Eye Safety
• IEC 60825-1, EN 60825
EMI
• FCC 47 CFR Part 15 Subpart B Class B, EN 55022, CISPR 22
ESD
• IEC 61000-4-2, MIL-STD-883E, EIA-JESD22-A115-A
Ordering Information
Product Interface
Standard
Te mp er a t u r e
-5 to 70
LCP-1250A4FDRJ LCP-1250A4FDRTJ Duplex LC MultiMode 550m
Wide
Te mp e r a t u r e
-40 to 85
Connectors Fiber Type
Link Distance
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Max.
LCP-1250B4QDRJ LCP-1250B4QDRTJ Duplex LC SingleMode 10km
LCP-1250B4MDRJ LCP-1250B4MDRTJ Duplex LC SingleMode 40km
Note: The actual link distance of a particular ber optic link depends on the optical budget, the number of connectors and splices, and cabling quantity. Please measure and verify the
actual link loss values once the link is established to identify any potential performance issues.
50
Industry
LCP-1FE Series
1-Port Fast Ethernet SFP Fiber Transceivers
Ethernet Switches
Compliant with IEEE 802.3u
Full duplex operation
Supports IEEE 802.3x ow control
DDM diagnosis function enhances transmission quality
Duplex LC connector interface
Hot-Pluggable for maximum exibility
TTL signal detection indicator
Class 1 laser product (Compliant with IEC 60825-1 and IEC 60825-2)
Metal case for better EMI immunity
Wide operating temperature
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Specications
TECHNOLOGY
Standard Compliance
• IEEE 802.3u 100Base-FX
INTERFACE
Fast Ethernet
• Port number: 1
• Connectors: Duplex LC
Digital Diagnostics Monitoring Function (DDM )
Basic Information
• Ethernet Compliance Code, Vendor Name, Wavelength, Distance
Note1: All Enhanced Parameters listed above include alarm and warning thresholds
Note2: DDM function is fully compatible with Delta DVS series Industrial Ethernet Switches
Enhanced Parameters
• Temperature, Supply Voltage, Transmitted Bias Current, Transmitted Power, Received Power
Fiber Optics
100Base-FX
LCP-155A4HDR LCP-155B4JDR  LCP-155B4MDR
Cable
Wavelength
Max. TX Power
Min. TX Power
RX Sensitivity
Optical Budget
62.5/125μm MultiMode 9/125μm SingleMode
1310nm 1310nm
-14dBm -8dBm
-20dBm -15dBm
-31dBm -31dBm
11dBm 16dBm
51
9/125μm SingleMode
1310nm
0dBm
-5dBm
-34dBm
29dBm
PHYSICAL
Housing
• Metal case
Dimensions
• 8.5 mm (H) x 13.4 mm (W) x 57 mm (D)
Industry
Installation
• Hot-swappable, pluggable
ENVIRONMENTAL LIMITS
Operating Temperature
Standard Models:
• -5℃ to 70℃(23˚F to 158˚F)
Wide Temp. Models:
• -40℃ to 85℃ (-40˚F to 185˚F)
Storage Temperature
• -40℃ to 85℃(-40˚F to 185˚F)
Ambient Relative Humidity
• 5% to 95% (non-condensing)
APPROVALS
Safety
• UL 60950-1, EN 60950-1
Laser Eye Safety
• IEC 60825-1, EN 60825
EMI
• FCC 47 CFR Part 15 Subpart B Class B, EN 55022, CISPR 22
ESD
• IEC 61000-4-2, MIL-STD-883E, EIA-JESD22-A115-A
Ordering Information
Product Interface
Standard
Temperature
-5℃ to 70
LCP-155A4HDRJ LCP-155A4HDRTJ Duplex LC MultiMode 5km
LCP-155B4JDRJ LCP-155B4JDRTJ Duplex LC SingleMode 30km
Wide
Temperature
-40℃ to 85
Connectors Fiber Type
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Max.
Link Distance
LCP-155B4MDRJ LCP-155B4MDRTJ Duplex LC SingleMode 60km
Note: The actual link distance of a particular ber optic link depends on the optical budget, the number of connectors and splices, and cabling quantity. Please measure and verify the
actual link loss values once the link is established to identify any potential performance issues.
52
Industry
IEEE 802.11 WLAN
Functions
Wireless Management ............................................................................................................................................................................... 54
Wireless AP
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
DVW-W02W2-E2 Series: Industrial IEEE 802.11 a/b/g/n Wireless AP/WDS/Client/Gateway ...................................................................... 58
High-gain Antennas
DVW-ANTRM8N-B3 Series: 2.4 & 5GHz Dual-band Omni-directional 5.5 & 8dBi High-gain Antennas ....................................................... 61
DVW-ANTRM7G-B3 Series: 2.4GHz Omni-directional 7dBi High-gain Antennas ....................................................................................... 62
53
IEEE 802.11 WLAN
IEEE 802.11n Technology
The IEEE 802.11n standard is improved with better data rates by Multiple-input and Multiple­output (MIMO) technology. It supports a bandwidth from 20 MHz to 40 MHz that doubles the speed of transmission performance and is compatible with previous IEEE 802.11 a/b/g standards.
Enhanced WLAN Security Management
A complete set of security verication tools ensures the security of WLAN for users.
Multiple protection mechanisms protect the network from unauthorized access.
Voice Traffic
Wi-Fi Multimedia
Quality of Service (QoS) prioritizes activities in queue, providing exceptional quality for wireless transmission, and is particularly effective for
multimedia applications and internet calls.
Top Priority
Video Traffic
High Priority
Best Effort Traffic
Low Priority
20MHz
Best Effort
IEEE 802.11 a/b/g
WEP
WPA/WPA2
SSID
802.1x
TACACS+
SNMP v3
Video Voice
Industry
40MHz
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
STP/RSTP
Incorrect wiring frequently causes loops that affect network operation. STP/ RSTP protects networks from this type of harm and builds a redundancy
path which contributes to a highly reliable network system.
Versatile Wireless Spot
Wireless Distribution
System (WDS) Point-to-
Multipoint Mode
Replacing traditional wired LAN extensions, this mode enables a LAN extension of two or more LANs through wireless connection.
Wireless Distribution
System Repeater Mode
Wireless connection is often limited by the effective transmission distance between two ends. The WDS repeater mode extends the transmission distance to overcome this distance limit.
Slave
Slave
AP mode
Blocked
Master
Slave
Slave
Client mode
Repeater
54
Industry
MODBUS Cache
■ Speeds up data loading time
■ Online real-time monitoring
DVW series switches provide a dynamic and constant communication between equipments. Responses are given in
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
no time when the host requests via Ethernet, which signicantly
improves the data rates of serial equipments.
Host
Ethernet Serial
Fast Response
Online Real-time Monitoring
Alarm Indicators
POWER
RUN
ERROR
COM1
0
1
IN
DVP-12SA
Digital Inputs
Designed for industrial environments, the DVW series industrial Ethernet switches easily connect to various industrial devices, such as PLCs or sensors. The DVW series delivers real-time alarms to users via relay output or email.
A Seamless Interconnection
USB Console Interface
A simple USB cable is all you need to make network management settings.
Adjustable Terminal Resistors
For applications that use RS-485, signal reection in cables often causes
interference and poor communication quality. Using adjustable terminal resistors that switch on/off according to requirements improves communication quality.
DVW NB
USB cable
55
Introduction to Serial Device Servers
Industry
Virtual COM
The virtual COM mode corresponds the serial port of a DVW to the COM port of a PC, providing users with direct access from a PC to serial communication devices via wired or wireless communication.
COM6 = 192.168.1.200:2000
Ethernet
RS-232/422/485
COM5 = 192.168.1.100:1000
TCP Client
AH500 PLC
In a TCP/IP network, each serial port has one exclusive set of IP address and TCP serial port number. When a DVW receives the data of the serial devices connected, it actively requests the host for connection and data transmission via wired or wireless communication. The connection is cut after the data transmission is completed.
TCP Server
In a TCP/IP network, each serial port has one exclusive set of IP address and TCP serial port number. When the host requests connection, a DVW passively receives the request for connection and conducts transmission of serial device data via wired or wireless communication.
1
AH500 PLC
Ethernet
2
RS-232/422/485
UDP Mode
Serial devices can connect to hosts for continuous data transmission via wired or wireless communication with a DVW. The UDP mode enables better transmission performance compared to the TCP mode, and it is suitable for real-time information display systems, such as electronic billboards. It is less applicable to highly critical systems.
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
1
Ethernet
2
RS-232/422/485
Pair Connection
AH500 PLC
Ethernet
RS-232/422/485
AH500 PLC
Pair a DVW with a serial host and another with a serial device. The pairs can use the existing wired or wireless network for communication. When the distance exceeds 100m, replace the network cable with RS-485 for a longer transmission distance
of up to 1,200m.
AH500 PLC
RS-232/422/485
Ethernet
RS-232/422/485
Serial Device
IN
POWER
RUN
ERROR
COM1
DVP-12SA
0
1
56
Industry
AH500 PLC
Ethernet Switches
SCADA
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Introduction to MODBUS Gateway
32 TCP Masters with 32 TCP Slaves
Via wired or wireless communication, up to 32 TCP masters can connect to serial slave devices, and each serial master can connect up to 32 TCP slaves.
Ethernet
RS-232/422/485
RS-485 Max. distance 1,200m
SCADA Max. 32 MODBUS TCP Masters
AH500 PLC
RS-232/422/485
EthernetEthernet
Serial Device
IN
POWER
RUN
ERROR
COM1
DVP-12SA
0
1
PLC
S/S
POWER
RUN
X0
ERROR
X1
COM1
X2
X3
IN
X4
RUN
X5
X6
X7
STOP
C0
Y0
Y1
OUT
COM1
Y2
Y3
SG
COM3+ COM3-
DVP-12SE
Ethernet
R
Ethernet
RS-485
RTU-485
Delta IEXplorer Search Tool
IEXplorer provides users with a friendly access to search for all IES products on the network. One simple click calls for the Web page for software function setting.
RS-485
57
DVW-W02W2-E2
Industrial IEEE 802.11 a/b/g/n Wireless AP/WDS/Client/Gateway
Compliant with IEEE 802.11n wireless technology capable
of up to 450Mbps data rate
Backward compatible with 802.11 a/b/g standards for
seamless integration
Multiple Wireless Modes: AP, Client CPE, WDS P-T-P, WDS
P-T-MP and Repeater
3 x 3 MIMO technology increases data rate
Wireless QoS (IEEE 802.11e, WMM) for video packets
precedence transmission
Enhanced wireless security: 64/128-bit WEP, WPA/
WPA2, WPA-PSK/WPA2-PSK (TKIP/AES) and 802.1x
Authentication
Enhanced LAN security: MAC/IP/TCP/UDP ltering, HTTPS,
SSL, 802.1X
Supports 2-port RS-232/422/485-to-Ethernet Device Server
Up to 16 simultaneous connections allows multiple hosts
collection
Built-in 2-port MODBUS ASCII/RTU to MODBUS TCP
Gateway
Up to 32 TCP masters or 32 TCP slaves per port at the
same time
Built-in 20MB buffer memory avoids data loss once the
connection is down
STP/RSTP for network redundancy further
ensures reliability and avoids network loops
Automatic IP assignment by DHCP/BootP
server for easy network construction
SNTP (simple network time protocol) for
network clock synchronization
Broadcast/Multicast/Unknown Unicast storm
control improves throughput problems
MAC addresses locking function per Ethernet
port blocks unauthorized access
USB console interface for easy connection with
laptops
Supports MODBUS TCP protocol for facilitating
the remote management by SCADA or with
other industrial devices
CPU utilization displays the amount of work the
CPU handles
Auto warning by email, DI, relay, Syslog &
SNMP trap
Industry
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Specications
TECHNOLOGY
Standard Compliance
• IEEE 802.11 a/b/g/n Wireless LAN
• IEEE 802.11i Wireless Security
• IEEE 802.11e QoS(WMM)
• IEEE 802.3 10Base-T
• IEEE 802.3u 100Base-T(X)
• IEEE 802.3ab 1000Base-T
INTERFACE
Wireless
IEEE 802.11 a/b/g/n:
• 3T3R
• IEEE 802.3x Flow Control
• IEEE 802.1D Spanning Tree Protocol
• IEEE 802.1w Rapid Spanning Tree Protocol
• IEEE 802.1Q VLAN Tagging
• IEEE 802.1X Port Authentication
Antennas:
• 3 2dBi omni-directional, RP-SMA (male) connector
58
Processing Type
• CSMA/CA
Industry
INTERFACE
Gigabit Ethernet
RJ45 Ports:
• 2 10/100/1000Base-T, auto MDI/MDI-X, auto negotiation
Serial Communication
Serial Ports :
• 2 RS-232/422/485, Terminal Block (8 contacts per port), 2KV isolation protection
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Baud Rate:
• 110bps to 921.6kbps
Data Bits:
• 7, 8
Parity:
• None, Even, Odd, Space, Mark
Stop Bits:
• 1, 2
Flow Control:
• RTS/CTS (RS-232 only), DTR/DSR, XON/XOFF
RS-232:
• TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422:
• Tx+, Tx-, Rx+, Rx-, GND
RS-485 (2-wire) :
• D+, D-, GND
RS-485 (4-wire) :
• Tx+, Tx-, Rx+, Rx-, GND
Wireless RF
RF Modulation
802.11a:
• BPSK, QPSK, 16QAM, 64QAM with OFDM
802.11b:
• DBPSK, DQPSK with DSSS, CCK
802.11g:
• BPSK, QPSK, 16QAM, 64QAM with OFDM
802.11n:
• BPSK, QPSK, 16QAM, 64QAM with MIMO-
OFDM
Frequency Band
2.400GHz ~ 5.850GHz
Operating Channels
US(FCC):
• 2.412GHz ~ 2.462GHz (11 channels)
• 5.180GHz ~ 5.240GHz (4 channels)
5.745GHz ~ 5.825GHz (5 channels)
EU(ETSI):
• 2.412GHz ~ 2.472GHz (13 channels)
• 5.180GHz ~ 5.240GHz (4 channels)
China(SRRC):
• 2.4000GHz ~ 2.4835GHz (13 channels)
• 5.725GHz ~ 5.850GHz (5 channels)
Taiwan(NCC):
• 2.412GHz ~ 2.462GHz (11 channels)
• 5.280GHz ~ 5.320GHz (3 channels)
5.745GHz ~ 5.825GHz (5 channels)
Data Transmission Rates
802.11n mode:
• up to 450Mbps
802.11a mode:
• 6, 9, 12, 18, 24, 36, 48, 54Mbps
802.11b mode:
• 1, 2, 5.5, 11Mbps
802.11g mode:
• 6, 9, 12, 18, 24, 36, 48, 54Mbps
Console Port
• USB B-Type connector
LEDs
Wireless Mode:
• Client, AP/WDS
Device:
• Signal Strength, Status, PWR1, PWR2, DI, ALARM
RJ45 Ports:
• 10/100/1000M, LINK/ACT
Serial Ports:
• COM1 RX, COM1 TX, COM2 RX, COM2 TX
Digital Inputs (DI)
• 1 set
• 0~+5V is OFF
• +11V~30V is ON
• Max. input current 6mA
Alarm Contacts (DO)
• 1 relay output
• Carry current 2A@24V
DC
Terminal Resistor Switches
2 sets, 120KΩ
Reset Button
• 1 set
RF Output Power (Max., per chain)
802.11a:
• 6Mbps to 24Mbps: 17dBm (±2dBm)
• 36Mbps: 16dBm (±2dBm)
• 48Mbps: 14dBm (±2dBm)
• 54Mbps: 13dBm (±2dBm)
802.11b (per chain):
• 1Mbps to 11Mbps: 19dBm (±2dBm)
802.11g:
• 6Mbps to 36Mbps: 19dBm (±2dBm)
• 48Mbps: 18dBm (±2dBm)
• 54Mbps: 17dBm (±2dBm)
RF Output Power MIMO (Max., per chain)
802.11n (2.4G HT20):
• MCS0~5, 8~13, 16~19: 18dBm (±2dBm)
• MCS6, 20: 17dBm (±2dBm)
• MCS14, 21, 22: 16dBm (±2dBm)
• MCS7, 15, 23: 15dBm (±2dBm)
802.11n (2.4G HT40):
• MCS0~5, 8~13, 16~19: 17dBm (±2dBm)
• MCS6, 20, 21: 16dBm (±2dBm)
• MCS14, 22: 16dBm (±2dBm)
• MCS7, 14, 15, 23: 15dBm (±2dBm)
802.11n (5G HT20):
• MCS0~4, 8~12, 16~19: 16dBm (±2dBm)
• MCS5: 15dBm (±2dBm)
• MCS6, 13, 20: 14dBm (±2dBm)
• MCS7, 15, 23: 12dBm (±2dBm)
802.11n (5G HT40):
• MCS0~4, 8~11, 16~19: 16dBm (±2dBm)
• MCS5, 12: 15dBm (±2dBm)
• MCS6, 13, 20: 14dBm (±2dBm)
• MCS7, 15, 22: 12dBm (±2dBm)
• MCS23: 11dBm (±2dBm)
Receiver Sensitivity
802.11a:
-93dBm @ 6Mbps, -85dBm @ 36Mbps
-81dBm @ 48Mbps, -79dBm @ 54Mbps
802.11b:
• -96dBm @ 1Mbps, -90dBm @ 11Mbps
802.11g:
• -94dBm @ 6Mbps, -86dBm @ 36Mbps
-82dBm @ 48Mbps, -80dBm @ 54Mbps
Receiver Sensitivity MIMO
802.11n(2G HT20):
• -93dBm @ MCS0, -81dBm @ MCS5,
-79dBm @ MCS6, -76dBm @ MCS7
• -93dBm @ MCS8, -83dBm @ MCS12,
-77dBm @ MCS14, -75dBm @ MCS15
• -92dBm @ MCS16, -82dBm @ MCS20,
-75dBm @ MCS22, -72dBm @ MCS23
802.11n(2G HT40):
• -90dBm @ MCS0, -79dBm @ MCS5,
-75dBm @ MCS6, -74dBm @ MCS7
• -90dBm @ MCS8, -81dBm @ MCS12,
-74dBm @ MCS14, -72dBm @ MCS15
• -90dBm @ MCS16, -79dBm @ MCS20,
-72dBm @ MCS22, -69dBm @ MCS23
802.11n(5G HT20):
• -92dBm @ MCS0, -91dBm @ MCS2,
-83dBm @ MCS4, -79dBm @ MCS5,
-77dBm @ MCS6, -74dBm @ MCS7
• -91dBm @ MCS8, -81dBm @ MCS12,
-71dBm @ MCS15
• -90dBm @ MCS16, -79dBm @ MCS20,
-72dBm @ MCS22, -69dBm @ MCS23
802.11n(5G HT40):
• -89dBm @ MCS0, -88dBm @ MCS2,
-81dBm @ MCS4, -77dBm @ MCS5,
-74dBm @ MCS6, -72dBm @ MCS7
• -89dBm @ MCS8, -78dBm @ MCS12,
-71dBm @ MCS15
• -88dBm @ MCS16, -77dBm @ MCS20,
-71dBm @ MCS22, -69dBm @ MCS23
59
Industry
Specications
MANAGEMENT
Software
• STP/RSTP, QoS, VLAN, SSH, DNS, HTTP, HTTPS, RADIUS, SNMP v1/v2c/ v3, SNMP Traps, TFTP, BootP Server/ Client, DHCP Server/Client, Telnet, Syslog, SMTP, SNTP Server/Client, ARP, MODBUS TCP
Security
Security Access:
MAC/IP/TCP/UDP ltering, HTTPS, SSH,
802.1X, SNMP v3
Wireless Security:
• 802.11i, 64/128-bit WEP, WPA/WPA2, WPA-PSK/WPA2-PSK (TKIP/AES)
• SSID Broadcast: Enable/Disable
Virtual COM Drivers
• Windows 2000, Windows XP
• Windows Vista (32/64 bits)
• Windows 7 (32/64 bits)
Conguration
• Web Browser, Cisco-like Telnet
MIB
• MIB II, RS-232 MIB, System Group
POWER REQUIREMENTS PHYSICAL
Input Voltage
• 2 sets, 12 to 48 VDC redundant terminal block input
Input Current
• Max. 1.02A
Overload Current Protection:
• Present, max. input current 3A
Reverse Polarity Protection
• Present
Buffer Time
• Min. 12ms at 24V
DC
Housing
• IP40 metal case
Dimensions
• 145.3 mm (H) x 112.5 mm (W) x 108.7 mm (D)
Weight
• 500g
Installation
• Industrial DIN-Rail and wall mounting
ENVIRONMENTAL LIMITS
Operating Temperature
• -40℃ to 75℃(-40˚F to 167˚F)
Storage Temperature
• -40℃ to 85℃(-40˚F to 185˚F)
Ambient Relative Humidity
• 5% to 95% (non-condensing)
CLI, USB Local Console, SNMP, MODBUS TCP, IEXplorer Utility
MIB, SNMP MIB, Interface Group MIB, TCP MIB, UDP MIB, IP MIB, Delta Private MIB
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
APPROVALS
Safety
• UL 508, EN 60950-1, IEC 61131-2
EMI
• FCC 47 CFR Part 15 Subpart B Class A,
• IEC 61000-6-4, EN 55022(CISPR22), EN 301 489-1/17
EMS
[EN 301 489-1/17, IEC 61000-6-2, EN 55024(CISPR24)]
• IEC 61000-4-2 level 3, IEC 61000-4-3 level 3, IEC 61000-4-4 level 4, IEC 61000-4-5 level 3,
IEC 61000-4-6 level 3, IEC 61000-4-8 level 4, IEC 61000-4-29
RF
• EN 300 328, EN 301 893, NCC, SRRC
• FCC 47 CFR Part 15 Subpart C, E
Environmental Type Tests
Cold Temperature:
• IEC 60068-2-1
Dry Heat:
IEC 60068-2-2
Humidity:
• IEC 60068-2-30
Shock:
• IEC 60255-21-2
Freefall:
• IEC 60068-2-32
Vibration:
• IEC 60068-2-6
Hi-Pot:
• 1.5KV
Ordering Information
Product Port Combination Interface RF
Region
Model Name
Operating
Temperature
10/100/1000
Base-T
RS-232/422/485 DI
DO
(Relay)
Power
Input
Band
DVW-W02W2-E2 -40℃ to 75℃ 2 2 1 1 2 US USA, Taiwan
DVW-W02W2-E2-EU -40℃ to 75℃ 2 2 1 1 2 EU European Union
DVW-W02W2-E2-CN -40℃ to 75℃ 2 2 1 1 2 CN China
Optional Products
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply
60
Industry
DVW-ANTRM8N-B3 Series
2.4 & 5GHz Dual-band Omni-directional
5.5 & 8dBi High-gain Antennas
Ethernet Switches
8dBi high-gain antenna to enhance wireless access performance
Powerful magnetic base with 3 meters extended cable, RP-SMA (male)
connector
IP65 weather proof with UV resistant design, suitable for all weather conditions
Easy installation for indoor or outdoor environments
Specications
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
ANTENNA CHARACTERISTICS
Standard Compliance
Wireless Signal:
• IEEE 802.11 a/b/g/n
Typical Application:
• Indoor / Outdoor
Frequency:
• 2.4 to 2.5GHz
• 4.9 to 5.9GHz
PHYSICAL CHARACTERISTICS
Base
Connector:
• RP-SMA (male) for device, N-type (female) for antenna
Low-Loss Cable Length:
• 3 meters
Low-Loss Cable Type:
• CFD-200-NL
Low-Loss Cable Power Loss:
Radome Material:
• Brass
2.4dBi (2.4GHz)
3.2dBi (5GHz)
Antenna Type:
• Omni-directional
Typical Gain:
• 5.5dBi @ 2.4GHz
• 8dBi @ 5GHz
Radome Color:
• Black
Height:
• 44.6mm
Diameter:
• 77.4mm
Weight:
• 56g
Installation:
• Magnetic mount
Beam Width:
• 2.4GHz @ H: 360° / E: 60.1°
• 5.8GHz @ H: 360° / E: 21.3°
Polarization:
• Vertical
V.S.W.R:
2.0
Antenna
Connector:
• N-type (male)
IP Protection:
• IP65
Radome Material:
• Fiberglass, UV resistant
Radome Color:
• White
Length:
• 203mm
Diameter:
• 22.4mm
Weight:
• 86g
Power Handling:
• 5W
Impedance:
50Ω±5Ω
ENVIRONMENTAL LIMITS
Operating Temperature
• -30℃ to 60℃(-22˚F to 140˚F)
Storage Temperature
• -40℃ to 85℃(-40˚F to 185˚F)
Ambient Relative Humidity
• 5% to 95% (non-condensing)
FIELD PATTERNS
H-PLANE for 2.4GHz E-PLANE for 2.4GHz H-PLANE for 5.8GHz E-PLANE for 5.8GHz
61
DVW-ANTRM7G-B3 Series
2.4GHz Omni-directional 7dBi High-gain Antennas
7 dBi high-gain antenna to enhance wireless access performance
Powerful magnetic base with 3 meters extended cable,
RP-SMA (male) connector
IP65 weather proof with UV resistant design, suitable for all weather conditions
Easy installation for indoor or outdoor environments
Industry
Ethernet Switches
Specications
ANTENNA CHARACTERISTICS
Standard Compliance
Wireless Singal:
• IEEE 802.11 b/g/n
Typical Application:
• Indoor / Outdoor
Frequency:
• 2.4 to 2.5GHz
Antenna Type:
• Omni-directional
Typical Gain:
• 7dBi
Beam Width:
• H: 360° / E: 20.7
PHYSICAL CHARACTERISTICS
Base
Connector:
• RP-SMA (male) for device, N-type (female) for antenna
Low-Loss Cable Length:
• 3 meters
Low-Loss Cable Type:
• CFD-200-NL
Low-Loss Cable Power Loss:
2.4dBi
Radome Material:
• Brass
Radome Color:
• Black
Height:
• 44.6mm
Diameter:
• 77.4mm
Weight:
• 56g
Installation:
• Magnetic mount
Polarization:
• Vertical
V.S.W.R:
2.0
Power Handling:
• 10W
Antenna
Connector:
• N-type (male)
IP Protection:
• IP65
Radome Material:
• Fiberglass, UV resistant
Radome Color:
• White
Length:
• 450mm
Diameter:
• 20mm
Weight:
• 180g
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Impedance:
50Ω±5Ω
ENVIRONMENTAL LIMITS
Operating Temperature
• -30℃ to 60℃(-22˚F to 140˚F)
Storage Temperature
• -40℃ to 85℃(-40˚F to 185˚F)
Ambient Relative Humidity
• 5% to 95% (non-condensing)
FIELD PATTERNS
H-PLANE E-PLANE
62
Industry
IIoT Routers
DX-2100 Series: Industrial 3G Cloud Routers ............................................................................................................................................. 64
DX-2300 Series: Industrial Ethernet Cloud Routers ...................................................................................................................................
Cloud Routers
67
Ethernet Switches
VPN Routers
DX-3001H9-V Series: Industrial 3G/WAN VPN Routers ............................................................................................................................. 70
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
63
DX-2100 Series
Industrial 3G Cloud Routers
Data acquisition equipment connected to cloud servers.
Supports a two-way data collection channel between the
device and the cloud
Sets up a secure tunnel between the user and the remote
device via the cloud server, without the need of additional
VPN servers
Supports MODBUS TCP and MODBUS ASCII/RTU protocols
Using UMTS/HSPA+ 3G technology, supports a wide
range of bands (800/850, 900, AWS1700, 1900, 2100 MHz),
downward compatible with GSM / GPRS / EDGE 2G network
HSPA+ data transmission rate up to 21.6 Mbps (downlink)/
5.76Mbps (uplink)
Automatic APN parameter matching and connection redial
Various peripheral interfaces include RS-485, RS-232 and
LAN ports
Built-in RTC and supports NTP time synchronization over a
network
Firewall functions: Stateful Packet Inspection (SPI), Prevent
Denial of Service (DoS) attacks, NAT, port triggering, port
mapping, IP address ltering, MAC address ltering, URL
ltering
Supports TCP/IP, UDP, ICMP, DHCP, HTTP, DNS
and SSH protocols
Scheduled jobs are available
Device congurations import /export
Network data ow statistics
Networking failure diagnostics
Device and PLC interlocking
Custom alarm conditions with email alerts
Industry
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Specications
TECHNOLOGY
Standard Compliance
• GSM/GPRS/EDGE/UMTS/HSPA+
• IEEE 802.3 10Base-T
• IEEE 802.3u 100Base-T(X)
INTERFACE
3G
GSM/GPRS/EDGE/UMTS/HSPA+ Antennas:
• 1 2.5dBi omni-directional, SMA(male) connector, 3 meters cable with magnetic stand
64
Industry
INTERFACE
Fast Ethernet
RJ45 Ports:
• 1 10/100Base-T(X), auto MDI/MDI-X, auto negotiation
Serial Communication
Serial Ports :
• 1 RS-232(DB9 male), 1 RS-485(DB9 female), 15KV isolation protection
Ethernet Switches
Baud Rate:
• 2400bps to 115200bps
Data Bits:
• 7, 8
Parity:
• None, Even, Odd
Stop Bits:
• 1, 2
Flow Control:
• RTS/CTS (RS-232 only), XON/XOFF
RS-232:
• TxD, RxD, RTS, CTS, GND
RS-485
• D+, D-, GND
LEDs
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Device:
• PWR, SD, Ready, 3G, Signal Strength
RJ45 Ports:
• LAN
Serial Ports:
• RS-232 RX, RS-232 TX, RS-485 RX, RS-485 TX
SIM Slot
• Number of SIMs: 1, Mini-SIM (25mm x 15mm)
• SIM Operating Voltage: 1.8V/3V
SD Socket
• SDHC(32mm x 24mm x 2.1mm), up to 32GB
Reset Button
• 1 set
MANAGEMENT
Cloud Service
• DIACloud
Software
• SSH, DNS, HTTP, TFTP, DHCP Server/Client, Telnet, Syslog, MODBUS TCP, NTP, MODBUS ASCII/RTU
Security
MAC/IP/URL ltering, SSH, SPI, Prevent denial of service (DoS) attacks, Port triggering, Port mapping
Virtual COM Drivers
• Windows XP, Windows Vista (32/64 bits), Windows 7 (32/64 bits)
Conguration
• Web Browser, DIACom, Android/iOS App
3G RF
Frequency Band:
• UMTS/HSPA+: 800/850, 900, AWS1700, 1900, 2100 MHz
• UMTS/HSPA+ (CN model): 900, 2100 MHz
• GSM/GPRS/EDGE: 850, 900, 1800, 1900 MHz
Data Transmission Rates
HSPA+:
• Up link 5.76 Mbps
• Down link 21.6 Mbps
UMTS:
• Up link 384 kbps
• Down link 384 kbps
EDGE:
• Up link 236.8 kbps
• Down link 296 kbps
GPRS:
• Up link 85.6 kbps
• Down link 85.6 kbps
RF Output Power:
• Class 4 (2 W, 33 dBm) @GSM 850 / 900
• Class 1 (1 W, 30 dBm) @GSM 1800 / 1900
• Class 3 (0.25 W,24 dBm) @UMTS
• Class E2 (0.5 W,27 dBm) @EDGE 850 / 900
• Class E2 (0.4 W,26 dBm) @EDGE 1800 / 1900
RF Output Power(CN model):
• Class 4 (33 dBm, -2.5/+0.5dBm) @GSM 850 / 900
• Class 1 (30 dBm, -2.5/+0.5dBm) @GSM 1800 / 1900
• Class 3 (24 dBm, -2.5dBm) @UMTS 2100/900
• Class E2 (27 dBm, -2.5/+1.5dBm)
• Class E2 (0.4 W,26 dBm)
Receiver Sensitivity :
• -108 dBm @ UMTS
• -107 dBm @ GSM 850 / 900 MHz
• -106 dBm @ DCS1800 / PCS1900 MHz
Receiver Sensitivity(CN model) :
• -109 dBm @ UMTS 2100 MHz
• -110 dBm @ UMTS 900 MHz
• -109.5 dBm @ GSM 850 MHz
• -109 dBm @ GSM 900 MHz
• -108 dBm @ DCS1800 / PCS1900 MHz
POWER REQUIREMENTS
Input Voltage
• 12 to 48VDC, 3 pin terminal block input
Input Current
• Max 1A
Overload Current Protection
• Present, Max. Input current 1.5A
Reverse Polarity Protection
• NOT Present
PHYSICAL
Housing
• IP30 metal case
Dimensions
• 111 mm(H) x 77 mm(W) x 26 mm (D)
Weight
• 196g
Installation
• Wall mounting
ENVIRONMENTAL LIMITS
Operating Temperature
• -20ºC to 70ºC (-4ºF to 158ºF)
Storage Temperature
• -40ºC to 85ºC (-40ºF to 185ºF)
Ambient Relative Humidity
• 5% to 95% (non-condensing)
65
Industry
Specications
APPROVALS
Safety
UL 60950-1, EN 60950-1 (DX-2100RW-WW certied)
EMI
• FCC 47 CFR Part 15 Subpart B Class A
EN 55022 (DX-2100RW-WW certied)
EN 301 489-1/7/24 (DX-2100RW-WW certied)
EMS
(EN 301 489-1/7/24, EN 55024)
• IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8
(DX-2100RW-WW certied)
• RF
EN 301 511, EN 301 908-1 (DX-2100RW-WW certied)
FCC Part 22H, 24E, 27 (DX-2100RW-WW certied)
Ordering Information
Product Port Combination Interface
Model Name
Operating
Temperature
10/100
Base-T(X)
RS-232 RS-485 DI
Environmental Type Tests
Cold Temperature:
• IEC 60068-2-1
Dry Heat:
IEC 60068-2-2
Humidity:
• IEC 60068-2-30
Shock:
• IEC 60255-21-2
Freefall:
• IEC 60068-2-32
Vibration:
• IEC 60068-2-6
Hi-Pot:
• 1.5KV
DO
(Relay)
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Region
Power Input
DX-2100RW-CN -20℃ to 70℃ 1 1 1 --- --- 1 China
DX-2100RW-WW -20℃ to 70℃ 1 1 1 --- --- 1 EU, USA
66
Industry
DX-2300 Series
Industrial Ethernet Cloud Routers
Ethernet Switches
Data acquisition device connected to cloud servers. Supports
a two-way data collection channel between the device and
the cloud
Sets up a secure tunnel between the user and the remote
device via the cloud server, without the need of additional
VPN servers
Supports MODBUS TCP and MODBUS ASCII/RTU protocols
Flexible connection method over WAN port, e.g. static IP,
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
DHCP client and more
Various peripheral interfaces include RS-485, RS-232 and
4 LAN ports
Built-in RTC and supports NTP time synchronization over
a network
Firewall functions: Stateful Packet Inspection (SPI), Prevent
Denial of Service (DoS) attacks, NAT, port triggering, port
mapping, IP address ltering, MAC address ltering, URL
ltering
Supports TCP/IP, UDP, ICMP, DHCP, HTTP, DNS and SSH
protocols
Scheduled jobs are available
Device congurations import /export
Network data ow statistics
Networking failure diagnostics
Device and PLC interlocking
Custom alarm conditions with email alerts
Specications
TECHNOLOGY
Standard Compliance
• IEEE 802.3 10Base-T
• IEEE 802.3u 100Base-T(X)
INTERFACE
Fast Ethernet
RJ45 Ports:
• WAN: 1 10/100Base-T(X), auto MDI/MDI-X, auto negotiation
• LAN: 4 10/100Base-T(X), auto MDI/MDI-X, auto negotiation
67
Industry
Specications
INTERFACE
Serial Communication
Serial Ports :
• 1 RS-232(DB9 male), 1 RS-485 (Terminal block), 15KV isolation protection
Baud Rate:
• 2400bps to 115200bps
Data Bits:
• 7, 8
Parity:
• None, Even, Odd
Stop Bits:
• 1, 2
Flow Control:
• RTS/CTS(RS-232 only), XON/XOFF
RS-232:
• TxD, RxD, RTS, CTS, GND
RS-485
• D+, D-, GND
LEDs
Device:
• PWR, SD, Ready
RJ45 Ports:
• 100M, LINK/ACT
Serial Ports:
• RS-232, RS-485
Reset Button
• 1 set
MANAGEMENT
Cloud Service
• DIACloud
Software
• SSH, DNS, HTTP, TFTP, DHCP Server/Client, Telnet, Syslog, MODBUS TCP, NTP, MODBUS ASCII/RTU
Security
MAC/IP/URL ltering, SSH, SPI, Prevent denial of service (DoS) attacks, Port triggering, Port mapping
Virtual COM Drivers
• Windows XP, Windows Vista (32/64 bits), Windows 7 (32/64 bits)
Conguration
• Web Browser, DIACom, Android/iOS App
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
POWER REQUIREMENTS
Input Voltage
• 9 to 40VDC, 2 pin terminal block input
Input Current
• Max. 0.53A
Overload Current Protection
• Present, Max. Input current 1.5A
Reverse Polarity Protection
• NOT Present
ENVIRONMENTAL LIMITS
Operating Temperature
• -20ºC to 70ºC (-4ºF to 158ºF)
Storage Temperature
• -40ºC to 85ºC (-40ºF to 185ºF)
Ambient Relative Humidity
• 5% to 95% (non-condensing)
PHYSICAL
Housing
• IP30 metal case
Dimensions
• 145.3 mm(H) x 45 mm(W) x 112.3 mm (D)
Weight
• 308g
Installation
• Industrial DIN-Rail and wall mounting
68
Industry
APPROVALS
Safety
• UL 60950-1, EN 60950-1
EMI
Ethernet Switches
• FCC 47 CFR Part 15 Subpart B Class A
• EN 55022
(EN 55024)
EMS
• IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8
Environmental Type Tests
Cold Temperature
• IEC 60068-2-1
Dry Heat:
• IEC 60068-2-2
Humidity:
• IEC 60068-2-30
Shock:
• IEC 60255-21-2
Freefall:
• IEC 60068-2-32
Vibration:
• IEC 60068-2-6
Hi-Pot:
• 1.5KV
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Ordering Information
Model Name
DX-2300LN-CN -20℃ to 70℃ 5 1 1 --- --- 1 China
DX-2300LN-WW -20℃ to 70℃ 5 1 1 --- --- 1 Worldwide
Product Port Combination Interface
Operating
Temperature
10/100
Base-T(X)
RS-232 RS-485 DI
DO
(Relay)
Region
Power Input
69
DX-3001H9-V Series
Industrial 3G/WAN VPN Routers
Supports IPSec, OpenVPN, PPTP, L2TP and GRE standard
VPN protocols, CA certicate in IPSec, L2TP over IPSec
Using UMTS/HSPA+ 3G technology, supports a wide
range of bands (850 / 800, 900, AWS1700, 1900, 2100 MHz).
Downward compatible with GSM/GPRS/EDGE 2G network
Dual SIM redundancy design: seamless switch between two
ISP systems for online continuity
HSPA+ data transmission rate up to 21.6Mbps (downlink) /
5.76Mbps (uplink)
Automatic APN parameter matching and connection redial
Flexible connection method over WAN port, e.g. static IP,
DHCP client and more
User congurable priorities of the connection to lnternet
over WAN and 2 cellular networks
Various peripheral interfaces include RS-485, RS-232 and
4 LAN ports
Built-in RTC and supports NTP time synchronization over
a network
Firewall functions: Stateful Packet Inspection (SPI),
Prevent Denial of Service (DoS) attacks, NAT,
port triggering, port mapping, IP address ltering,
MAC address ltering, URL ltering
Supports TCP/IP, UDP, ICMP, DHCP, HTTP, DNS
and SSH protocols
Device congurations import/export
Network data ow statistics
Networking failure diagnostics
Industry
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Specications
TECHNOLOGY
Standard Compliance
• GSM/GPRS/EDGE/UMTS/HSPA+
• IEEE 802.3 10Base-T
• IEEE 802.3u 100Base-T(X)
INTERFACE
3G
GSM/GPRS/EDGE/UMTS/HSPA+ Antennas:
• 1 2.5dBi omni-directional, SMA (male) connector, 3 meters cable with magnetic stand
70
Industry
Specications
INTERFACE
Fast Ethernet
RJ45 Ports:
• WAN: 1 10/100Base-T, auto MDI/MDI-X, auto negotiation
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
• LAN: 4 10/100Base-T, auto MDI/MDI-X, auto negotiation
Serial Communication
Serial Ports :
• 1 RS-232 (3-pin Terminal block), 1 RS-485 (3-pin Terminal block), 15KV isolation protection
Baud Rate:
• 2400bps to 115200bps
Data Bits:
• 7, 8
Parity:
• None, Even, Odd
Stop Bits:
• 1, 2
Flow Control:
• RTS/CTS (RS-232 only), XON/XOFF
RS-232:
• TxD, RxD, RTS, CTS, GND
RS-485
• D+, D-, GND
LEDs
Device:
• POWER, READY, SIM1, SIM2, SD, Signal Strength
RJ45 Ports:
• 100M, LINK/ACT
Serial Ports:
• RS-232, RS-485
SIM Slot
• Number of SIMs: 2, Mini-SIM (25mm x 15mm)
• SIM Operating Voltage: 1.8V/3V
SD Socket
• SDHC(32mm x 24mm x 2.1mm), up to 32GB
Reset Button
• 1 set
3G RF
Frequency Band:
• UMTS/HSPA+: 800/850, 900, AWS1700, 1900, 2100 MHz
• GSM/GPRS/EDGE: 850, 900, 1800, 1900 MHz
Data Transmission Rates
HSPA+:
• Up link 5.76 Mbps
• Down link 21.6 Mbps
UMTS:
• Up link 384 kbps
• Down link 384 kbps
EDGE:
• Up link 236.8 kbps
• Down link 296 kbps
GPRS:
• Up link 85.6 kbps
• Down link 85.6 kbps
RF Output Power:
• Class 4 (2 W, 33 dBm) @GSM 850 / 900
• Class 1 (1 W, 30 dBm) @GSM 1800 / 1900
• Class 3 (0.25 W, 24 dBm) @UMTS
• Class E2 (0.5 W, 27 dBm) @EDGE 850 / 900
• Class E2 (0.4 W, 26 dBm) @EDGE 1800 / 1900
Receiver Sensitivity :
• -108 dBm @ UMTS
• -107 dBm @ GSM 850 / 900 MHz
• -106 dBm @ DCS1800 / PCS1900 MHz
MANAGEMENT
VPN
• IPSec, OpenVPN, PPTP, L2TP, GRE
Software
• SSH, DNS, HTTP, TFTP, DHCP Server/Client, Syslog, NTP,
MODBUS RTU Master, SNMP Server
Security
MAC/IP/URL ltering, SSH, SPI, Prevent denial of service
(DoS) attacks, Port triggering, Port mapping
Conguration
• Web Browser
PHYSICAL
Housing
• IP30 metal case
Dimensions
• 145.3 mm (H) x 45 mm (W) x 112.3 mm (D)
Weight
• 372g
Installation
• Industrial DIN-Rail and Wall mounting
POWER REQUIREMENTS
Input Voltage
• 12 to 48VDC, 2 pin terminal block input
Input Current
• Max. 1A
Overload Current Protection
• Present, Max. Input current 1.5A
Reverse Polarity Protection
• Present
ENVIRONMENTAL LIMITS
Operating Temperature
• -20ºC to 70ºC (-4ºF to 158ºF)
Storage Temperature
• -40ºC to 85ºC (-40ºF to 185ºF)
Ambient Relative Humidity
• 5% to 95% (non-condensing)
71
APPROVALS
Safety
• UL 60950-1
• IEC 60950-1
EMI
• FCC 47 CFR Part 15 Subpart B Class B
• EN 55022
• EN 55032
• EN 301 489-1/7/24
EMS
(EN 301 489-1/7/24, EN 55024)
• IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8
RF
• EN 301 511, EN 301 908-1
• FCC Part 22H, 24E, 27
Environmental Type Tests
Cold Temperature:
• IEC 60068-2-1
Dry Heat:
• IEC 60068-2-2
Humidity:
• IEC 60068-2-30
Shock:
• IEC 60255-21-2
Freefall:
• IEC 60068-2-32
Vibration:
• IEC 60068-2-6
Hi-Pot:
• 1.5KV
Industry
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Ordering Information
Product Port Combination Interface
Region
Model Name
Operating
Temperature
10/100
Base-T(X)
RS-232 RS-485 DI
DO
(Relay)
Power Input
DX-3001H9-V -20℃ to 70℃ 5 1 1 --- --- 1 China, EU, USA
Optional Products
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply CliQII/PMC Series: 48 VDC Industrial Power Supply
72
Industry
Ethernet Converters
Protocol Converters
IFD9506 Series: Industrial 1-Port Serial-to-Ethernet MODBUS Converters ................................................................................................ 74
IFD9507 Series: Industrial 1-Port MODBUS Serial-to-EtherNet/IP Converters ........................................................................................... 77
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converter
73
IFD9506 Series
Industrial 1-Port Serial-to-Ethernet MODBUS Converters
Standard MODBUS TCP protocol with universal compatibility
MODBUS RS-232/485 to MODBUS TCP Converter
MODBUS TCP server connections: 16 (serial master mode)
MODBUS TCP client connections: 8 (serial slave mode)
Connectable to various devices and Ethernet ports with user-dened format
Serial servers support simultaneous duplex transmissions of user-dened data (1 on 1)
Isolation in RS-485 channel for stable communication
Smart Monitor function for faster response from the Ethernet end in serial master mode
Provides Web browser settings and real-time monitoring of terminal devices
Virtual COM enables Ethernet communication for software that only supports serial
Real-time automatic alarm notications through email when triggered by DI
IP lter function for enhanced network security
Industry
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Specications
TECHNOLOGY
Standard Compliance
• IEEE 802.3 10Base-T
• IEEE 802.3u 100Base-T(X)
INTERFACE
RJ45 Ports:
• 1 10/100Base-T(X), auto MDI/MDI-X, auto
negotiation
Serial Communication
Serial Ports:
• 1 RS-232/485, 2KV isolation protection
Baud Rate:
• 110bps to 115.2kbps
Data Bits:
• 7, 8
MANAGEMENT
Protocol
• ICMP, IP, TCP, UDP, DHCP, SMTP,
MODBUS TCP
Security
Security Access:
IP ltering
Parity:
• None, Even, Odd,
Stop Bits:
• 1, 2
RS-232:
• TxD, RxD, GND
RS-485 (2-wire):
• D+, D-, GND
LEDs
Device:
• Power
Virtual COM Drivers
• Windows 2000, Windows XP, Windows Vista (32/64 bits), Windows 7 (32/64 bits)
Conguration
• DCISoft, Web Browser, IEXplorer Utility
RJ45 Ports:
• LINK/ACT
RS485 Ports:
• Rx
Digital Inputs (DI)
• 3 sets
• 0~+5V is OFF
• +15V~+30V is ON
• Max. input current 5mA
Reset Button
• 1 set
74
Industry
Specications
POWER REQUIREMENTS
Input Voltage
• 20.4 to 28.8 VDC terminal block input
Input Current
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converter
• Max. 0.15A
PHYSICAL
Dimensions
• 110.8 mm (H) x 71 mm (W) x 33 mm (D)
ENVIRONMENTAL LIMITS
Operating Temperature
• 0℃ to 55℃(32˚F to 131˚F)
APPROVALS
Safety
• UL 508, IEC 61131-2
EMI
• IEC 61000-6-4
EMS (IEC 61000-6-2)
• IEC 61000-4-2 Level 3, IEC 61000-4-3 Level 3 IEC 61000-4-4 Level 3, IEC 61000-4-5 Level 1 IEC 61000-4-6 Level 2
Overload Current Protection
• Present, Max. input current 0.17A
Reverse Polarity Protection
• Present
Weight
• 140g
Storage Temperature
• -25℃ to 70℃(-13˚F to 158˚F)
Environmental Type Tests
Cold Temperature:
• EN 61131-2
Dry Heat:
• EN 61131-2
Humidity:
• EN 61131-2-6.1.3
Buffer Time
• Min. 10ms at 24V
Installation
• Industrial DIN-Rail and wall mounting
Ambient Relative Humidity
• 5% to 95% (non-condensing)
Shock:
• EN 61131-2
Freefall:
• EN 61131-2 6.2.4
Vibration:
• EN 61131-2
Hi-Pot:
• 500V
DC
Ordering Information
Product Port Combination Interface
Model Name
IFD9506 0℃ to 55℃ 1 1 1 3 --- 1
Optional Products
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply
Operating
Temperature
10/100Base-T(X) RS-232 RS-485 DI
DO
(Relay)
Power
Input
75
IFD9507 Series
Industrial 1-Port MODBUS Serial-to-EtherNet/IP Converters
Industry
Standard EtherNet/IP and MODBUS TCP protocol with universal compatibility
EtherNet/IP to MODBUS RS-232/485 Converter
Supports EtherNet/IP protocol
EtherNet/IP server connections: 16 [Explicit Message, Implicit Message (cyclic ) : 1]
EtherNet/IP client connection: 4 (I/O connection only)
MODBUS RS-232/485 to MODBUS TCP Converter
MODBUS TCP server connections: 16 (serial master mode)
MODBUS TCP client connections: 8 (serial slave mode)
Connectable to various devices and Ethernet ports with user-dened format
Isolation in RS-485 channel for stable communication
Smart Monitor function for faster response from the Ethernet end in serial master mode
Provides Web browser settings and real-time monitoring of terminal devices
Virtual COM enables Ethernet communication for software that only supports serial
Real-time automatic alarm notications through email when triggered by DI
IP lter function for enhanced network security
Specications
TECHNOLOGY
Standard Compliance
• IEEE 802.3 10Base-T
• IEEE 802.3u 100Base-T(X)
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
INTERFACE
RJ45 Ports:
• 1 10/100Base-T(X), auto MDI/MDI-X, auto negotiation
Serial Communication
Serial Ports:
• 1 RS-232/485, 2KV isolation protection
Baud Rate:
• 110bps to 115.2kbps
Data Bits:
• 7, 8
MANAGEMENT
Protocol
• ICMP, IP, TCP, UDP, DHCP, SMTP,
MODBUS TCP, EtherNet/IP
Security
Security Access:
IP ltering
Parity:
• None, Even, Odd,
Stop Bits:
• 1, 2
RS-232:
• TxD, RxD, GND
RS-485 (2-wire):
• D+, D-, GND
LEDs
Device:
• Power
Virtual COM Drivers
• Windows 2000, Windows XP, Windows Vista (32/64 bits), Windows 7 (32/64 bits)
Conguration
• DCISoft, Web Browser, IEXplorer Utility
76
RJ45 Ports:
• LINK/ACT
RS485 Ports:
• Rx
Digital Inputs (DI)
• 3 sets
• 0~+5V is OFF
• +15V~+30V is ON
• Max. input current 5mA
Reset Button
• 1 set
Industry
Specications
POWER REQUIREMENTS
Input Voltage
• 20.4 to 28.8 VDC terminal block input
Input Current
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converter
• Max. 0.15A
PHYSICAL
Dimensions
• 110.8 mm (H) x 71 mm (W) x 33 mm (D)
ENVIRONMENTAL LIMITS
Operating Temperature
• 0℃ to 55℃ (32˚F to 131˚F)
APPROVALS
Safety
• UL 508, IEC 61131-2
EMI
• IEC 61000-6-4
EMS (IEC 61000-6-2)
• IEC 61000-4-2 Level 3, IEC 61000-4-3 Level 3 IEC 61000-4-4 Level 3, IEC 61000-4-5 Level 1 IEC 61000-4-6 Level 2
Overload Current Protection
• Present, max. input current 0.17A
Reverse Polarity Protection
• Present
Weight
• 140g
Storage Temperature
• -25℃ to 70℃ (-13˚F to 158˚F)
Environmental Type Tests
Cold Temperature:
• EN 61131-2
Dry Heat:
• EN 61131-2
Humidity:
• EN 61131-2-6.1.3
Buffer Time
• Min. 10ms at 24V
Installation
• Industrial DIN-Rail and wall mounting
Ambient Relative Humidity
• 5% to 95% (non-condensing)
Shock:
• EN 61131-2
Freefall:
• EN 61131-2 6.2.4
Vibration:
• EN 61131-2
Hi-Pot:
• 500V
DC
Ordering Information
Product Port Combination Interface
Model Name
IFD9507 0℃ to 55℃ 1 1 3 --- 1
Optional Products
DVP/DRP/PMC Series: 12/24 VDC Industrial Power Supply
Operating
Temperature
10/100Base-T(X) RS-232/485 DI
DO
(Relay)
Power
Input
77
Industry
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
78
Loading...