Delta Products Delta lndustrial Ethernet Catalog

Automation for a Changing World
Delta lndustrial Ethernet
Matched to Maximize
Delta Industrial Ethernet Products and Solutions (IES)
Adapting to the diversity of network communication applications, Delta’s IES series
industrial Ethernet products and solutions offer an abundant selection with excellent
quality in compact and durable designs. From Ethernet switches, IEEE 802.11 wireless
communication, mobile wireless communication, serial device servers to protocol gateways,
guarantees a seamless device integration that satisfies critical system applications in
industrial environments.
1
Table of Contents
Ethernet Switches
Tailoring to industrial applications that require highly reliable network systems, Delta's DVS series managed and unmanaged Ethernet switches provide better system performance with functions such as the redundant self-healing ring, high-end layer 2 management, and a wide-operating temperature from -40°C to 75°C. The EMC noise immunity complies with IEC standards and attains a high level 3/4. The intuitive design of the operating interface provides users with easy access and convenience.
Wireless IEEE 802.11
Delta helps users construct a reliable industrial wireless network by the WLAN products compatible with multiple communication protocols, such as IEEE 802.11 a/n in 5GHz or IEEE 802.11 b/g/n in 2.4GHz. Adopting Multiple-input and Multiple-output (MIMO) technology enables the network bandwidth reach 450Mbps. Delta WLAN products support multiple wireless connectors, including wireless access points, WDS, and clients for easy and economical construction of wireless LANs. The built-in 3-in-1 serial ports directly connect to industrial controllers, saving the effort and cost of cable connection. The built-in gateway for MODBUS, the most common industrial communication protocol, converts MODBUS Serial to MODBUS TCP, seamlessly interconnecting the existing equipment with the Ethernet communication network.
1
Industrial Ethernet Products and Solutions
Industry
3
Intelligent Transportation System
Wind Power
RGV Intelligent Warehouse Carriage Automation System
Solar Power
Automated CNC Production Line
13
Ethernet Switches
L2 Management Functions
Managed Switches
Unmanaged Switches
PoE+ Managed Switches
PoE+ Unmanaged Switches
SFP Fiber Transceivers
IEEE 802.11 WLAN
50
Wireless Management
Wireless AP
High-gain Antennas
IIoT Routers
60
Cloud Routers
VPN Routers
Ethernet Corverters
70
Protocol Converters
2
Industry
Intelligent Transportation System
DT3
The Intelligent Transportation System (ITS) integrates advanced electronic, information and sensing technologies for real-time transportation management of pedestrians, roads and traffic. The ITS effectively improves the safety, convenience, and efficiency of transportation, reducing carbon emissions from transportation and its impact on the environment, and supporting economic
Ethernet Switches
development.
Freeway Traffic Flow Monitoring System
CMS Real-Time Trafc Message Display System
Tunnel Signal and Alarm Monitoring System
Electronic Toll Collection System
DVS-110W02-3SFP
DVS-110W02-3SFP
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
7-port FE + 3-port GbE Combo Managed Ethernet Switch
IEEE 802.11 WLAN IIoT Routers
GbE ber port to enhance backbone
transmission
► STP / RSTP / MSTP for network
redundancy to ensure network reliability
► IP40 metal case, -40°C to 75°C
operating temperature
DVW-W02W2-E2
IEEE 802.11 a/b/g/n Wireless AP/WDS/Client/Gateway
► IEEE 802.11n up to 450Mbps data rate
► Supports 2-port RS-232 / 422 / 485 to
Ethernet Device Server
► IP40 metal case, -40°C to 75°C
operating temperature
DVS-G008I00A
8-port GbE Unmanaged Ethernet Switch
► Full GbE ports to enhance transmission
bandwidth
Ethernet Converters
► Jumbo frame size up to 9216 Bytes
► IP40 metal case, -10°C to 60°C operating
temperature
Exhaust Blower
HMI
Vehicle Detector
Visibility Sensor
Wind Sensor
Smoke Sensor
RTU-EN01
AH500
PV
8
8
8
8
SV
8
8
8
8
AT
OUT
ALM
SET
Temperature Sensor
DVS-110W02-3SFP
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
Air Detector
Fire Alarm
88
8
co
IFD9506
Serial-to-Ethernet MODBUS Converter
► RS-485 signal isolation protection
► Supports MODBUS TCP protocol
► Smart on-line monitoring function
3
DVS-110W02-3SFP
ETHERNET
R
1
3
DVW-W02W2-E2
Industry
GbE Fiber
Ethernet
Serial
I/O Sensor
Ethernet Switches
ALARM
1
2
PWR1
RESET
2
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
DVW-W02W2-E2
1
Antenna
2
DVW-W02W2-E2
3
TR1
OFF
ON
COM1
TR2
OFF
ON
TXD-
PWR2
COM2
STATUS
PWR1
TXD+
DCD RXD+ (D+)
COM1 RX
DI
TXD-
RXD RXD­(D-)
TXD+
TXD
COM2 RX
COM1 TX
DCD
GND
RXD+
DTR
(D+)
RXD
RS-422/485
CLIENT MODE
COM2 TX
RXD-
GND
(D-)
AP/BRIDGE
TXD
RS-232
ALARM
MODE
GND
DSR
DTR
RS-422/485
RTS
GND
RS-232
CTS
DSR
RTS
CONSOLE
10/100/
CTS
1000M
LAN1 LAN2
10/100/ 1000M
RESET
LINK / ACT
LINK / ACT
1
Antenna
PWR2
STATUS
PWR1
COM1 RX
DI
COM2 RX
COM1 TX
CLIENT MODE
COM2 TX
AP/BRIDGE
ALARM
MODE
CONSOLE
RESET
Trafc Gate
2
DVW-W02W2-E2
TR1
OFF
ON
COM1
TXD-
TXD+
DCD RXD+ (D+)
RXD RXD­(D-)
TXD
GND
DTR
RS-422/485
GND
RS-232
DSR
RTS
CTS
10/100/
1000M
LAN1 LAN2
LINK / ACT
3
TR2
OFF
ON
COM2
TXD-
TXD+
DCD RXD+ (D+)
RXD RXD­(D-)
TXD
GND
DTR
RS-422/485
GND
RS-232
DSR
RTS
CTS
10/100/
1000M
LINK / ACT
POWER
RUN
ERROR
COM1
RUN
STOP
COM1
DVP-12SE
DVP-12SE
Trafc Lights
S/S
X0
X1
X2
X3
IN
X4
X5
X6
X7
C0
Y0
Y1
OUT
Y2
Y3
SG
COM3+ COM3-
Ethernet
IFD9506
RS-232
RS-485
POWER
DATA
BAUDRATE
FORMAT
SLAVE ADDRESS
88
LINK/ACT
RSSET
RS485
1
10
SC
D -D+X2X1X0
S/S
24V
0V
Trafc Lights
IP CAM
DVS-G008I00A
DVS-008
PWR
1
6
7
100M
LINK
8
ACT
POWER
RUN
ALARM
RTU-485
RS-485
ID 7
DIP
ID 6 ID 5 ID 4 ID 3 ID 2 ID 1
1 2 3 4 5 6 7 8
ON
ID 0
PA 3 PA 2
DIP
PA 1 PA 0 DR 2 DR 1 DR 0
1 2 3 4 5 6 7 8
ON
A / R
RTU-485
IP CAM
ETC Tag Reader
DVS-110W02-3SFP
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
IEEE 802.11 WLAN IIoT Routers
Ethernet Converters
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
DVS-110W02-3SFP
4
Industry
Wind Power
Wind power has emerged as an alternative energy solution in recent years. Wind power plants are
typically located in remote areas, often within a vast territory. The ring network of ber optic Ethernet is
widely adopted for data transmission and management and real-time monitoring of power generation panels. These plant locations can be harsh and hazardous, with a large diurnal temperature variation.
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers
System reliability and transmission precision can only be guaranteed with highly noise-immune and durable network devices.
DVS-110W02-3SFP
7-port FE + 3-port GbE Combo Managed Ethernet Switch
GbE ber port to enhance backbone
transmission
► STP / RSTP / MSTP for network
redundancy to ensure network reliability
► IP40 metal case, -40°C to 75°C
operating temperature
DVS-016 Series
16-port FE Unmanaged Ethernet Switch
► Broadcast Storm Protection
► Auto warning for link-down and power
failure by relay output
► IP40 metal case, -40°C to 75°C
operating temperature
Ethernet Converters
Control Center
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
GE8
100/
10/100
1000M
/1000M
LINK ACT
LINK
GE9
ACT
2/5
GE10
CONSOLE
100M
LINK ACT
DVS-110W02-3SFP
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
DVS-110W02­3SFP
DVS-110W02-3SFP
1
3/6
10/
4/7
5
GbE/FE Fiber
Ethernet
Serial
Industry
Ethernet Switches
DVS-016W01-MC01
AH500
PORT ALARM
1
2
3
4
1
DVS-016
ALARM
2
PWR1
3
PWR2
5
4
100M
TX
11
6
RX
12
2
7
13
8
3
14
9
100M
4
15
10
LINK ACT
16
DVS-110W02-3SFP
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
DVP-12SE
S/S
POWER
RUN
X0
ERROR
X1
COM1
X2
X3
IN
X4
RUN
X5
X6
X7
STOP
C0
Y0
Y1
OUT
COM1
Y2
Y3
SG
COM3+ COM3-
DVP-12SE
Ethernet
R
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
DVS-110W02-3SFP
IEEE 802.11 WLAN IIoT Routers
Ethernet Converters
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
DVS-110W02-3SFP
DVS-110W02-3SFP
Rectiers RTU-EN01 Inverters
6
Industry
RGV Intelligent Warehouse Carriage Automation System
Wireless signal transmission technology can be applied in various areas. Delta's DVW series matches with Leaky CoaXial Cable (LCX or Radiating Cable) to transform Wi-Fi into stable extension signals which can surround objects, walls, pillars, and transmit signals to every corner of the production
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers
line, enhancing Ethernet communication accessibility. They also offer high-speed real-time process capability. When applying the Delta DVW series and LCX to Rail Guided
they can assist factory operators carry materials, which enhances working efficiency and security for
maintenance personnel.
Industrial wireless warehouse automation and underground communication engineering
Wireless radio wave communication systems for rail transport and tunnel engineering
Provides automation and wireless communication solutions between floors in the same building
Vehicle (RGV) systems,
DVW-W02W2-E2
IEEE 802.11 a/b/g/n AP/WDS/Client/Gateway
► IEEE 802.11n up to 450Mbps data rate
► Supports 2-port RS-232/422/485 to
Ethernet Device Server
► IP40 metal case, -40 to 75°C operating
temperature
AH500 Series
Mid-range PLC
► Utilizes 32-bit processor ► Max. I/O points:
DIO: Max. 4,352 points AIO: Max. 544 channels RIO: >100,000 points
Ethernet Converters
► Program capacity: Max.
384 k steps (1.5 MB)
► Data register (D+L): 256 k words
► Excellent program execution speed:
LD instruction execution speed: 0.02 μs
► CPU built-in with fully isolated RS-232 / 422 / 485, Mini-
USB, Ethernet and SDHC card slot
RGV
AH PLC Master
1
Antenna
2
DVW-W02W2-E2
3
TR1
OFF
ON
COM1
TR2
OFF
ON
TXD-
PWR2
COM2
STATUS
PWR1
TXD+
DCD RXD+ (D+)
COM1 RX
DI
TXD-
RXD RXD­(D-)
TXD+
TXD
COM2 RX
COM1 TX
DCD
GND
RXD+
DTR
(D+)
RXD
RS-422/485
CLIENT MODE
COM2 TX
RXD-
GND
(D-)
AP/BRIDGE
TXD
RS-232
ALARM
MODE
GND
DSR
DTR
RS-422/485
RTS
GND
RS-232
CTS
DSR
RTS
CONSOLE
10/100/
CTS
1000M
LAN1 LAN2
10/100/ 1000M
RESET
LINK / ACT
LINK / ACT
DVW Client Mode
C200
7
Ethernet
Coaxial Cable
Leaky Coaxial Cable
Industry
Ethernet Switches
AH PLC MasterDVW AP Mode
1
Antenna
2
DVW-W02W2-E2
3
TR1
OFF
ON
COM1
TR2
OFF
ON
TXD-
PWR2
COM2
STATUS
PWR1
TXD+
DCD RXD+ (D+)
COM1 RX
DI
TXD-
RXD RXD­(D-)
TXD+
TXD
COM2 RX
COM1 TX
DCD
GND
RXD+
DTR
(D+)
RXD
RS-422/485
CLIENT MODE
COM2 TX
RXD-
GND
(D-)
AP/BRIDGE
TXD
RS-232
ALARM
MODE
GND
DSR
DTR
RS-422/485
RTS
GND
RS-232
CTS
DSR
RTS
CONSOLE
10/100/
CTS
1000M
LAN1 LA N2
10/100/ 1000M
RESET
LINK / ACT
LINK / ACT
SCADA
IEEE 802.11 WLAN IIoT Routers
RGV
100M Leaky Coaxial Cable
Obstruction
RGV
SCADA AH PLC Master
Ethernet Converters
DVW AP Mode
1
Antenna
2
DVW-W02W2-E2
3
TR1
OFF
ON
COM1
TR2
OFF
ON
TXD-
PWR2
COM2
STATUS
PWR1
TXD+
DCD RXD+ (D+)
COM1 RX
DI
TXD-
RXD RXD­(D-)
TXD+
TXD
COM2 RX
COM1 TX
DCD
GND
RXD+
DTR
(D+)
RXD
RS-422/485
CLIENT MODE
COM2 TX
RXD-
GND
(D-)
AP/BRIDGE
TXD
RS-232
ALARM
MODE
GND
DSR
DTR
RS-422/485
RTS
GND
RS-232
CTS
DSR
RTS
CONSOLE
10/100/
CTS
1000M
LAN1 LA N2
10/100/ 1000M
RESET
LINK / ACT
LINK / ACT
8
Industry
R
Solar Power
Governments worldwide actively seek renewable clean energy for their electricity infrastructure in recent years. Solar power systems are one of the main programs. Most solar power plants are located in remote, vast areas of a country. The monitoring system constructed by Industrial Ethernet establishes highly stable and multiple redundant network systems for a power plant. It also facilitates
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers
real-time monitoring and continuous production by the highest generating capacity.
DVS-108W02-2SFP
6-port FE + 2-port GbE Combo Managed Ethernet Switch
GbE ber port to enhance backbone transmission
► ONE RING, ONE CHAIN for rapid
network redundancy to ensure network reliability , recovery time less than 20ms
► IP40 metal case, -40°C to 75°C
operating temperature
DVS-G408W01
IP Camera
1
2
O
N
PWR1
PWR2
ALARM
8
7
6
5
DVS-G408W01
4
3
2
1
PoE10/100 /1000M
8-port GbE+ PoE+ Unmanaged Ethernet Switch
► 8 10 / 100 / 1000 Base-T PoE+ (PSE) ports.
Based on IEEE 802.3at standard up to
30 W per port
► Auto warning by relay output for
power failure
► IP30 metal case, -40°C to 70°C
operating temperature
DX-2100RW
3G Cloud Router
► UMTS / HSPA+ : 800 / 850 , 900,
AWS1700, 1900, 2100 MHz
► Supports DIACloud Cloud Management
Platform
► IP30 metal case, -20°C to 70°C
Ethernet Converters
operating temperature
DVP-SE
Advanced Slim PLC
S/S
POWER
RUN
X0
ERROR
X1
COM1
X2
X3
IN
X4
RUN
X5
X6
X7
STOP
C0
Y0
Y1
OUT
COM1
Y2
Y3
SG
ALARM
COM3+
1 2
1
PWR1
COM3-
DVP-12SE
R
PV Inverter (DC/AC)
RESET
2
3 4
PWR2
3
DI1
4
DI2
D
V S
­1 0
8 W
0 2
­2 S
F
Ethernet
P
GE7
1 0 0
1
/
0 / 1 0
0
1 0 0
/
0
1
M
0 0 0 M
L I N K A C T
1/4
L I N
GE8
K A CT
2/5
1 0
CONSOLE
/ 1 0 0 M
3/6
L I N K A C T
S/S
POWER
RUN
X0
ERROR
X1
COM1
X2
X3
IN
X4
RUN
X5
X6
X7
STOP
C0
Y0
Y1
OUT
COM1
Y2
Y3
SG
COM3+ COM3-
DVP-12SE
ALARM
Ethernet
1 2
1
PWR1
RESET
2
3 4
PWR2
3
DI1
4
DI2
D
V S
­1 0 8 W
0 2
­2
S F P
GE7
1 0 0
1
/
0 / 1 0
0
1
0 0
/
0
1
M
0 0 0 M
L
I N K
A
C T
1/4
L I N
GE8
K A CT
2/5
1 0
CONSOLE
/ 1 0 0 M
3/6
L I N K A C T
Battery Bank
Specic Solar Tracking instruction
► Program capacity: 16 K steps, Data
register: 12 K words; Higher execution
Utility Grid
speed, LD:0.64 µs, MOV:2 µs
► Built-in MODBUS TCP and EthernNet/IP
9
R
R
R
GbE Fiber
Ethernet
Power Line
Industry
Ethernet Switches
PoE+ switch (DVS-G400 Series)
Gigabit Fiber Ring
S/S
POWER
RUN
X0
ERROR
X1
COM1
X2
X3
IN
X4
RUN
X5
X6
X7
STOP
C0
Y0
Y1
OUT
COM1
Y2
Y3
SG
COM3+ COM3-
DVP-12SE
Ethernet
PLC (DVP Series)
ALARM
1 2
1
PWR1
RESET
2
3 4
PWR2
3
DI1
4
DI2
D
V S
­1 0 8 W
0
2
­2 S
F P
GE7
1 0 0
1
/
0 / 1
0 0
1 0 0
/
0
1
M
0 0
0 M
L I N
K A C T
1/4
L I N
GE8
K A CT
2/5
1 0
CONSOLE
/ 1 0 0
M
3/6
L I N
K A C
T
ALARM
1 2
1
PWR1
RESET
2
3 4
PWR2
3
DI1
4
DI2
D V
S
­1
0 8
W 0
2
­2 S
F P
GE7
1 0 0
1
/
0 / 1
0 0
1
0 0
/
0
1
M
0 0
0 M
L
I N K
A
C T
1/4
L I N
GE8
K A CT
2/5
1 0
CONSOLE
/ 1 0 0
M
3/6
L I N
K A C
T
Managed Switch (DVS-100 Series)
Gigabit Fiber Ring
POWER
RUN
ERROR
COM1
RUN
STOP
OUT
COM1
COM3+ COM3-
DVP-12SE
Ethernet
10/100M
5
1
PWR1
DVS-328R02-8SFP
R.M / CPLG.R
ALARM
PWR2
PWR3
PWR1
DI
PWR3
-/N +/L
0V V+
C.HD / C.TL
3 5 7 9
1
2
4 6 8 10
0V V+
RESET
PWR2
V+ V-
678910
234
DI
ALARM
LINK/ACT 100M LINK/ ACT 10/1 00/10 00M LINK/ACT LINK/ ACT100/1000M
2123252725
15 171921
11
23
13
18 20 22242224262826
FECombo GEComboFE
12 14 16
Managed Switch (DVS-300 Series)
27
CONSOLE
28
IEEE 802.11 WLAN IIoT Routers
DX
­2
1
0
0
R e
a d y
3 G
T X
R S
4 8
5 R X
L A
N
T X
PW
R
SD
R S
2 3
2 R X
1
2
3
4
5
2
­R X
D
5
4
3
-
3
T XD
2
1
5
­G N
D
7
­R
6
T S
7
8
9
8
­C T S
R S2
3
9
2
8
7
6
R S4
8
5
DX
­2
1
0
0
R
e a
d y
3 G
T X
R S
4 8
5
R
X L A
N
T X
PW
R
SD
R S
2 3
2
R
X
1
2
3
4
5
2
­R X
D
5
4
3
-
3
T XD
2
1
5
­G N
D
7
­R
6
T
S
7
8
9
8
­C T
S
R
S2
3
9
2
8
7
6
R
S4 8
5
S/S
X0
X1
X2
X3
IN
X4
X5
X6
X7
C0
Y0
Y1
Y2
Y3
SG
ALARM
1 2
1
PWR1
RESET
2
3 4
PWR2
3
DI1
4
DI2
D V
S
­1
0 8 W
0 2
­2 S F
P
GE7
1 0 0
1
/
0 / 1 0 0
1
0 0
/
0
1
M
0 0 0 M
L
I N K
A
C T
1/4
L I N
GE8
K A CT
2/5
1 0
CONSOLE
/ 1 0 0 M
3/6
L I N K A C T
3G Cloud Router (DX-2100 Series)
1
­G
N D
2
­D
-
3
­D
+
S/S
POWER
RUN
X0
ERROR
X1
COM1
X2
X3
IN
X4
RUN
X5
X6
X7
STOP
C0
Y0
Y1
OUT
COM1
Y2
Y3
ALARM
1 2
1
PWR1
RESET
SG
2
3 4
PWR2
COM3+
3
DI1
COM3-
4
DI2
DVP-12SE
S/S
POWER
RUN
X0
ERROR
X1
COM1
X2
X3
IN
X4
RUN
X5
X6
X7
STOP
C0
Y0
Y1
OUT
COM1
Y2
Y3
SG
COM3+ COM3-
DVP-12SE
Ethernet
R
Ethernet
ALARM
1 2
1
PWR1
RESET
2
3 4
PWR2
3
DI1
4
DI2
D V S
­1 0
8 W
0 2
­2 S F
P
GE7
1 0 0
1
/
0 / 1 0 0
1
0 0
/
0
1
M
0 0 0 M
L
I N K
A
C T
1/4
L I N
GE8
K A CT
2/5
1 0
CONSOLE
/ 1 0 0 M
3/6
L I N K A C T
Managed Switch (DVS-100 Series)
D V
S
­1
0 8 W
0 2
­2 S F
P
GE7
1 0 0
1
/
0 / 1 0 0
1
0 0
/
0
1
M
0 0 0 M
L
I N K
A
C T
1/4
L I N
GE8
K A CT
2/5
1 0
CONSOLE
/ 1 0 0 M
3/6
L I N K A C T
1
­G N
D
2
­D
-
3
­D +
INTERNET
1 2
O N
PWR1
PWR2
ALARM
8
7
6
5
DVS-G408W01
4
3
2
1
PoE10/100 /1000M
PoE+ Switch (DVS-G400 Series)
Remote Control Center
IP Camera
Ethernet Converters
10
Industry
Automated CNC Production Line
Unmanned factories is the ultimate goal for industrial automation. The logistics of an automated production line is an indispensable part of that goal. The use of robots, unmanned vehicles and other equipment, and data transmission and exchange via an industrial wireless network allows immediate
acquisition of the status of the production line from the control room, and signicantly increases the
overall productivity and quality.
Ethernet Switches
DVW-W02W2-E2
IEEE 802.11 a/b/g/n Wireless AP/WDS/Client/Gateway
► IEEE 802.11n up to 450 Mbps data
rate
► Supports 2-port RS-232/422/485 to
Ethernet Device Server
► IP40 metal case, -40°C to 75°C
operating temperature
PLC (AH500 Series)
IEEE 802.11 WLAN IIoT Routers
DVS-008 Series
8-port FE Unmanaged Ethernet Switch
► Broadcast Storm Protection
► Auto warning for link-down and power
failure by relay output
► IP40 metal case, -40°C to 75°C
operating temperature
AH500 Series
Mid-range PLC
► Utilizes 32-bit processor ► Max. I/O points:
DIO: Max. 4,352 points AIO: Max. 544 channels RIO: >100,000 points
► Program capacity: Max.
384 k steps (1.5 MB)
► Data register (D+L): 256 k words
► Excellent program execution speed:
LD instruction execution speed: 0.02 μs
Ethernet Converters
► CPU built-in with fully isolated RS-232 / 422 / 485, Mini-
USB, Ethernet and SDHC card slot
PORT ALARM
1
2
3
DVS-008
4
1
ALARM
2
PWR1
3
PWR2
4
TX
100M
RX
5
TX
3
2
6
RX
4
4
7
100M
5
LINK ACT
8
Unmanaged Switch (DVS-008 Series)
DVP-SE Series
Advanced Slim PLC
► Remote I/O function is suitable for
distributed sequence control
► Program capacity: 16k steps, Data register:
12k words; Higher execution speed, LD:0.64µs, MOV:2µs
► Built-in MODBUS TCP and EtherNet/IP
11
Industry
R
R
S/S
POWER
DVPEN01
RUN
X0
POWER
ERROR
X1
RS-232
COM1
X2
100M
X3
IN
LINK
X4
RUN
X5
X6
X7
STOP
ON
C0
Y0
Y1
OUT
COM1
Y2
Y3
SG
COM3+ COM3-
DVP-12SE
Ethernet
R
PLC (DVP Series)
1
Antenna
2
DVW-W02W2-E2
3
TR1
OFF
ON
COM1
TR2
OFF
ON
TXD-
PWR2
COM2
STATUS
PWR1
TXD+
DCD RXD+ (D+)
COM1 RX
DI
TXD-
RXD RXD­(D-)
TXD+
TXD
COM2 RX
COM1 TX
DCD
GND
RXD+
DTR
(D+)
RXD
RS-422/485
CLIENT MODE
COM2 TX
RXD-
GND
(D-)
AP/BRIDGE
TXD
RS-232
ALARM
MODE
GND
DSR
DTR
RS-422/485
RTS
GND
RS-232
CTS
DSR
RTS
CONSOLE
10/100/
CTS
1000M
LAN1 LAN2
10/100/ 1000M
RESET
LINK / ACT
LINK / ACT
WiFi AP (DVW Series)
1
Antenna
2
DVW-W02W2-E2
3
TR1
OFF
ON
COM1
TR2
OFF
ON
TXD-
PWR2
COM2
STATUS
PWR1
TXD+
DCD RXD+ (D+)
COM1 RX
DI
TXD-
RXD RXD­(D-)
TXD+
TXD
COM2 RX
COM1 TX
DCD
GND
RXD+
DTR
(D+)
RXD
RS-422/485
CLIENT MODE
COM2 TX
RXD-
GND
(D-)
AP/BRIDGE
TXD
RS-232
ALARM
MODE
GND
DSR
DTR
RS-422/485
RTS
GND
RS-232
CTS
DSR
RTS
CONSOLE
10/100/
CTS
1000M
LAN1 LAN2
10/100/ 1000M
RESET
LINK / ACT
LINK / ACT
WiFi Client (DVW Series)
POWER
RUN
ERROR
COM1
RUN
STOP
COM1
DVP-12SE
S/S
X0
X1
X2
X3
IN
X4
X5
X6
X7
C0
Y0
Y1
OUT
Y2
Y3
SG
COM3+ COM3-
Ethernet
Ethernet
Ethernet Switches
CNC Machine
IEEE 802.11 WLAN IIoT Routers
Robot Arm
S/S
POWER
DVPEN01
RUN
X0
POWER
ERROR
X1
RS-232
COM1
X2
100M
X3
IN
LINK
X4
RUN
X5
X6
X7
STOP
ON
C0
Y0
Y1
OUT
COM1
Y2
Y3
SG
COM3+ COM3-
DVP-12SE
Ethernet
Material zone
1
Antenna
2
DVW-W02W2-E2
3
TR1
OFF
ON
COM1
TR2
OFF
ON
TXD-
PWR2
COM2
STATUS
PWR1
TXD+
DCD RXD+ (D+)
COM1 RX
DI
TXD-
RXD RXD­(D-)
TXD+
TXD
COM2 RX
COM1 TX
DCD
GND
RXD+
DTR
(D+)
RXD
RS-422/485
CLIENT MODE
COM2 TX
RXD-
GND
(D-)
AP/BRIDGE
TXD
RS-232
ALARM
MODE
GND
DSR
DTR
RS-422/485
RTS
GND
RS-232
CTS
DSR
RTS
CONSOLE
10/100/
CTS
1000M
LAN1 LAN2
10/100/ 1000M
RESET
LINK / ACT
LINK / ACT
Production zone
(Phase I)
1
Antenna
2
DVW-W02W2-E2
3
TR1
OFF
ON
COM1
TR2
OFF
ON
TXD-
PWR2
COM2
STATUS
PWR1
TXD+
DCD RXD+ (D+)
COM1 RX
DI
TXD-
RXD RXD­(D-)
TXD+
TXD
COM2 RX
COM1 TX
DCD
GND
RXD+
DTR
(D+)
RXD
RS-422/485
CLIENT MODE
COM2 TX
RXD-
GND
(D-)
AP/BRIDGE
TXD
RS-232
ALARM
MODE
GND
DSR
DTR
RS-422/485
RTS
GND
RS-232
CTS
DSR
RTS
CONSOLE
10/100/
CTS
1000M
LAN1 LAN2
10/100/ 1000M
RESET
LINK / ACT
LINK / ACT
Production zone
(Phase II)
Ethernet Converters
12
Industry
Ethernet Switches
Functions
Layer 2 Network Management ................................................................................................................................................................ 14
Managed Switches
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
DVS-328 Series: Managed Industrial 20-Port FE + 4-Port FE Combo 100Base-SFP + 4-Port GbE Combo 100/1000Base-SFP Rack
Mount Ethernet Switches ............................................................................................................................................. 18
DVS-110 Series: Managed Industrial 7-Port FE + 3-Port GbE Combo 100/1000Base-SFP Ethernet Switches ....................................... 21
DVS-109 Series: Managed Industrial 8-Port FE + 1-Port GbE Ethernet Switches ................................................................................... 24
DVS-108 Series: Managed Industrial 6-Port FE + 2-Port GbE Combo 100/1000Base-SFP Ethernet Switches ....................................... 27
Unmanaged Switches
DVS-G008I/G005I00A Series: Unmanaged Industrial 5 and 8-Port GbE Ethernet Switches ................................................................... 30
DVS-016 Series: Unmanaged Industrial 16-Port FE Ethernet Switches .................................................................................................. 32
DVS-008 Series: Unmanaged Industrial 8-Port FE Ethernet Switches .................................................................................................... 34
DVS-005 Series: Unmanaged Industrial 5-Port FE Ethernet Switches .................................................................................................... 36
PoE Managed Switches
DVS-G512 Series: IEEE 802.3 af/at PoE+ Managed Industrial 8-Port GbE (PSE)
+ 4-Port 100/1000Base-SFP Ethernet Switches ...................................................................................................................................... 38
PoE Unmanaged Switches
DVS-G408 Series: IEEE 802.3af/at PoE+ Unmanaged Industrial 8-Port GbE Ethernet Switches ........................................................... 41
DVS-G406 Series: IEEE 802.3af/at PoE+ Unmanaged Industrial 4-Port GbE + 2-Port 100/1000Base-SFP Ethernet Switches
DVS-G402 Series: 2 10/100/1000Base-T Industrial IEEE 802.3af/at PoE+ Injectors .............................................................................. 45
DVS-G401 Series: 1 10/100/1000Base-T Industrial IEEE 802.3af/at PoE+ Splitters
.............................................................................. 47
............ 43
SFP Fiber Transceivers
LCP-GbE Series: 1-Port Gigabit Ethernet SFP Fiber Transceivers ......................................................................................................... 49
LCP-1FE Series: 1-Port Fast Ethernet SFP Fiber Transceivers ................................................................................................................51
13
Layer 2 Network Management
Network Redundancy Technology
IEEE published the 802.1D Spanning Tree Protocol (STP) in 1998, and in 2004 announced 802.1w Rapid Spanning Tree Protocol (RSTP), which is an enhancement to STP. These network protocols are used to construct backup paths for transmission when a link fails and are applied in network structures with demands for high reliability. In current industrial automation and critical system applications, as the high
demand for faster convergence time grows, STP and SRTP’s speed, whose unit of convergence time is seconds, becomes insufcient. Delta
thoroughly understands customers’ needs from different industries. To meet the high demand for speed and reliability, Delta introduced ONE RING and ONE CHAIN ultra-speed redundant protocol to satisfy our customers’ needs, which provides faster speed and more functions than STP and RSTP.
ONE RING
Network self-healing brings most recovery
Delta's proprietary self-healing redundant ring technology is called ONE RING. ONE RING can enable redundant paths and provide self-healing recovery time of less than 20 milliseconds to ensure fluent data transmission with minimum loss when any nodes fail or meet default in a ring network. In addition, ONE RING offers customers the selection of Trunking Ring, Multi-Ring, Ring Coupling, and Dual-Homing modes to satisfy their specific needs. With strong ring network functions, ONE RING provides highly flexible and highly reliable network structures, which greatly save on wiring cost.
Industry
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Trunking Ring
Multi-Ring
Ring Coupling
Dual-Homing
ONE CHAIN
Multi-Network self-healing brings most efficient and trust
Delta's self-healing redundant chain technology is called“ONE CHAIN".
ONE CHAIN is a new generation of Network Redundancy Technology with unlimited expansion functions derived from the design concept of ONE RING.
ONE CHAIN is able to offer backup paths within 20 milliseconds when several network nodes fail at the same time to ensure fluent data transmission with minimum loss. Its high speed self-healing time is especially suitable for high-end automation network structures such as a Distributed Control System (DCS). ONE CHAIN is compatible with other existing large Internet backbone network switches, which saves costs for wiring and for changing new switches such as equipment, labor, and time.
14
Industry
PS05-A1
PS05-A1
PS05-A1
Advanced Network Management
VLAN
A Virtual Local Area Network (VLAN) is a network topology configured according to a logical scheme rather than a physical layout. VLANs allow users to break up switched environments into multiple broadcast domains, and can be used to combine any collection of LAN segments into an autonomous user group that
Ethernet Switches
appears as a single LAN. It enhances performance by conserving bandwidth and improves security by limiting traffic to specific domains. VLANs can be created statically by hand and dynamically through GVRP.
Trunking
The physical ports of a switch can be aggregated by a logical scheme into a group which forms a physical link. This link serves as a redundant path which enhances bandwidth and improves performance
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Quality of Service (QoS)
Network packet prioritization is a process which prioritizes the transmission of packets with a queue. It ensures prompt packet scheduling that is especially effective for delay-sensitive packets and audio or image transmissions with optimal quality of service
IP CAM
AH500
RTU
16AM10N
POWER
16AM10N
16AM10N
16AM10N
I/O0
I/O1
PULL
I/O2
I/O3
POWER
16AM10N
16AM10N
16AM10N
16AM10N
I/O0
I/O1
PULL
I/O2
I/O3
POWER
16AM10N
16AM10N
16AM10N
16AM10N
I/O0
I/O1
PULL
I/O2
I/O3
Top Priority
High Priority
Low Priority
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
ZONE A
16AM10N
I/O4
16AM10N
I/O4
16AM10N
I/O4
1
S/S
POWER
RUN
X0
ERROR
X1
COM1
X2
X3
IN
X4
RUN
X5
X6
X7
STOP
C0
Y0
Y1
OUT
COM1
Y2
Y3
SG
COM3+ COM3-
DVP-12SE
Ethernet
R
VLAN1
ALARM
1
PWR1
1
2
RESET
2
PWR2
3
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
Enhanced bandwidth
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
VLAN2
VLAN3
ALARM
1
PWR1
1
2
RESET
2
PWR2
3
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
Low High To p
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK
ACT
ZONE B
1
S/S
POWER
RUN
X0
ERROR
X1
COM1
X2
X3
IN
X4
RUN
X5
X6
X7
STOP
C0
Y0
Y1
OUT
COM1
Y2
Y3
SG
COM3+ COM3-
DVP-12SE
Ethernet
R
Server
Link Layer Discovery Protocol (LLDP)
The LLDP protocol is used by network devices for advertising their identity, capabilities, and any updates to neighboring devices on an IEEE 802.ab network. These messages are stored in SNMP MIB and can be searched through a network management system.
DHCP Relay Option 82 IP Assignment
DHCP Relay Option 82 delivers additional client information such as ports
connected, VLAN, as well as MAC addresses to a DHCP server for more exible
IP addresses assignment.
Enhanced Network Security Management
A complete set of security verication tools further ensures network security for
users. Multiple protection mechanisms are incorporated in network management to protect it from unauthorized network access during operation.
ALARM
1
1
2
PWR1
2
3
PWR2
4
3
DI1
4
DI2
GE8
SW B
GE9
GE10
CONSOLE
ALARM
1
1
2
PWR1
2
3
PWR2
4
3
DI1
4
DI2
GE10
CONSOLE
SW A
1. IP address request
RESET
DVS-110W02-3SFP
100/
10/100
1000M
/1000M
LINK ACT
1
LINK ACT
2/5
3/6
10/ 100M
4/7
LINK ACT
RESET
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
3/6
10/ 100M
4/7
LINK ACT
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
4. Your IP address
192.168.1.5
TACACS+
IEEE 802.1X
SNMP v3
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
I know I have neighbors
SW A, B, C, D
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
3. Your IP address
192.168.1.5
ACL
SSH
HTTPS
SW C
SW D
2. IP address request VLAN 8, Port 8
15
Industry
Simple Network Management Protocol (SNMP)
Delta Managed Ethernet Switches support v1, v2c and v3 versions of SNMP. For users, SNMP Trap messages allow real-time event alarms for authentication failures, cold/warm starts, link-downs, and many more.
MODBUS TCP & EtherNet/IP Manager
Delta Managed Ethernet Switches support MODBUS TCP and EtherNet/IP protocol for easy integration with an on-site industrial network management system. Users can monitor and manage the operational status via the graphical interface of Supervisory Control and Data Acquisition (SCADA) at any time. The consistency of communication protocols helps users save big on equipment management costs.
0x1000 : Port 1 link-up
0x1000
NMS
(Manager)
MODBUS TCP & EtherNet/IP
Smart Functions Well-tailored to Your Needs
Authentication
Cold/Warm start
Link-down
SCADA
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Relay Output for Event Alarms
Delta Managed Ethernet Switches have built-in relay output for event alarms. Any occurrence of preset default events and any digital inputs will trigger alarms. With real-time notification, on-site personnel can quickly diagnose and eliminate any incidents.
Digital Inputs
Designed for industrial environments, the DVS series industrial Ethernet switches easily connect to various industrial devices, such as PLCs or sensors. It delivers real-time alarms to users via relay output or email.
Redundant Power Inputs
The design of dual power inputs provides excellent integration with the common dual power supply design of critical systems, or with industrial environments. It secures switches from potential power impact and provides highly-reliable and uninterrupted network transmission.
Alarm Indicators
Adjust
DC OK
Adjust
DC OK
16
Industry
A Seamless Interconnection
USB Console Interface
A simple USB cable is all you need to carry out network management settings.
Ethernet Switches
Real-time Web Display
A real-time Web display tells users the connection status of each port with indicators on a Web page. With an uninterrupted network connection, users can manage operations in remote places at any time.
SFP DDM
Utilizing the built-in digital diagnostic monitor (DDM) function of the DVS series Industrial Ethernet Switches, users can continuously monitor the current operation
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
status of the Delta SFP ber transceiver and the transmission quality through a
datasheet displayed on the web.
DVS NB
USB cable
Watch Dog Timer
The hardware Watch Dog Timer restores switches from malfunctions caused by any reasons, such as an incorrect network topology or a malicious network attack. It ensures switches work properly in harsh industrial environments.
Delta IEXplorer Search Tool
IEXplorer provides friendly access to search for all IES products on the network. One simple click calls up the Web page for setting software functions.
ALARM
1
1
2
PWR1
RESET
2
3
PWR2
4
3
DI1
4
DI2
DVS-110W02-3SFP
GE8
100/
10/100
1000M
/1000M
LINK ACT
1
LINK
GE9
ACT
2/5
GE10
3/6
10/
CONSOLE
100M
4/7
LINK ACT
GOOD
NG
CPU malfunction = 6 seconds = Auto Reset
17
DVS-328 series
Managed Industrial 20 10/100Base-T(X) + 4 10/100Base­T(X) combo 100Base-SFP + 4 10/100/1000Base-T combo 100/1000Base-SFP Rack Mount Ethernet Switch
2
3
Industry
Ethernet Switches
IPv6 address suitable for larger network and
neighbor discovery
Automatic IP assignment by DHCP/BootP server for
easy network construction
DHCP relay option 82 for sending DHCP requests
with clients’ identities to a DHCP server
Port-based DHCP server with IP and MAC binding
makes IP maintenance much easier
Q-in-Q double VLAN to distinguish multiple VLANs
SNMP v1/v2c/v3 facilitates the exchange of
management between network devices
Supports EtherNet/IP and MODBUS TCP protocols
that facilitates the remote management by SCADA
and other industrial devices
Proprietary ONE RING and ONE CHAIN high end
redundancy technology, easy to build multiple ring
topology, self-healing recovery time < 20ms
STP/RSTP/MSTP for network redundancy further
ensures reliability
QoS(IEEE 802.1p) and TOS/DSCP for mission-critical
applications
IEEE 802.1Q VLAN, MAC-based VLAN, IP Subnet-
based VLAN, VLAN isolation and GVRP optimize
network strategy
Enhanced network security with IEEE 802.1X,
TACACS+, SSH, HTTPS and SNMP v3
IEEE 802.3ad port trunking in parallel to increase the
link bandwidth
SNTP (simple network time protocol) for network clock
synchronization
Broadcast/Multicast / Unknown Unicast storm control
improves throughput problems
Loopback-Detection to avoid broadcast loops, and
shutdown the corresponding ports automatically
Cable diagnostic provides the mechanism to detect and
report potential cabling issues
Intelligent Access Control List(ACL)
MAC addresses locking function per port blocks
unauthorized access
USB console interface for easy connection with laptops
IGMP Snooping and GMVP prunes multicast trafc
RMON groups 1,2,3,9(history, statistics, alarms and
events) for enhanced ow management and analysis
CPU utilization displays the amount of works the CPU
handles
Port mirroring for Many-to-One ports online
troubleshooting
Versatile system le updates by TFTP, HTTPS or HTTP
DDM diagnosis function by SFP ber module
Auto warning by email, DI, relay, Syslog & SNMP trap
Compatible with various industrial protocols, including
EtherNet/IP, Pronet, CC-LINK IE and DNP 3.0
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Specications
TECHNOLOGY
Standard Compliance
IEEE 802.3 10Base-T
IEEE 802.3u 100Base-T(X) and 100Base-FX
IEEE 802.3ab 1000Base-T
IEEE 802.3z 1000Base-X
IEEE 802.3x Flow Control
IEEE 802.1D Spanning Tree Protocol
IEEE 802.1w Rapid Spanning Tree Protocol
• IEEE 802.1s Multiple Spanning Tree Protocol
• IEEE 802.1p Class of Service, Priority Protocols
• IEEE 802.1Q VLAN Tagging
• IEEE 802.1AD VLAN Q-in-Q
• IEEE 802.1X Port Authentication
• IEEE 802.3ad LACP Aggregation
• IEEE 802.1AB Link Layer Discovery Protocol
18
Processing Type
Store and Forward
IEEE 802.3x Flow control in
full duplex, back-pressure flow control in half duplex
Industry
Specications
INTERFACE
Fast Ethernet
RJ45 Ports
20 10/100Base-T(X), auto MDI/MDI-X, auto
negotiation
Fast Ethernet Combo Ports
RJ45 Ports:
4 10/100Base-T(X), auto MDI/MDI-X, auto
negotiation
SFP Ports:
Ethernet Switches
4 100Base-SFP
Gigabit Ethernet Combo Ports
RJ45 Ports:
4 10/100/1000Base-T, auto MDI/MDI-X, auto
negotiation
SFP Ports:
4 100/1000Base-SFP
PERFORMANCE AND SCALABILITY
Console Port
USB B-Type connector
LEDs
Device:
PWR1PWR2PWR3R.M/CPLG.RC.HD/ C.TLALARMDI
Ports:
100M(SFP port)100/1000M(SFP port) 10/100M(RJ45 port)10/100/1000M(RJ45 port)、LINK/ACT
Digital Inputs(DI)
1 set
0~+5V is OFF
+11V~30V is ON
Input current 6mA Max
Alarm Contacts(DO)
1 relay output
Carry current 2A @ 24V
Reset Button
1 set
DC
Switching Capacity
12.8Gbps, Wired speed, Non-blocking
switching fabric
Forwarding Rate
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
19Mpps
MAC Address Table
16K
MANAGEMENT
Software
STP/RSTP/MSTP, LACP, QoS, IGMP Snooping v1/v2/v3, IGMP Query v1/v2, GARP, GMRP, VLAN, VLAN Q-in-Q, VLAN unaware, SSH, DNS, HTTP, HTTPS, RADIUS, TACACS+, SNMP v1/v2c/v3, SNMP Traps, TFTP, RMON, LLDP, BootP Server/Client, DHCP Server/Client, DHCP L2 Relay, DHCP Relay Option 82, DHCP Option 66/67, RARP, Telnet, Syslog, SMTP, SNTP Server/Client, IPv6, MODBUS TCP, EtherNet/IP
Security
MAC filtering, HTTPS, SSH, 802.1x, TACACS+, SNMP v3
POWER REQUIREMENTS
Input Voltage
Installation: Front cabling. Industrial terminal block
LV: 2 sets 36 to 72VDC (Tested @ 36 to 60VDC)
HV: 1 set 85 to 264V
to 240VAC)
/ 88 to 370VDC (Tested @ 100
AC
Packet Buffer Memory
1.5M bits
IGMP Multicast Groups
256
Max. VLANs
255
Conguration
Web Browser, Cisco-like Telnet CLI, USB Local Console ,
MIB
MIB II, Bridge MIB, SNMP MIB, Ether-like MIB, Q-Bridge/
Input Current
LV: 0.75A
HV: 1.2A
Overload Current Protection
Present, Max. Input current 8A
Quality of Service
8 priority queues per port
DHCP/BootP Server
1,275 IP addresses
Jumbo Frame
9,216 Bytes
SNMP, MODBUS TCP, IEXplorer Utility
P-Bridge MIB, IF MIB, Traceroute MIB, TCP MIB, UDP MIB, IP MIB, RMON Group 1,2,3,9, Delta Private MIB
Reverse Polarity Protection
• Present (VDC input )
Buffer Time
Min. 12ms @ 48 VDC
PHYSICAL
Housing
IP40 metal case
Dimensions
44 mm(H) x 440 mm(W) x 257 mm (D)
ENVIRONMENTAL LIMITS
Operating Temperature
-25 to 70(-13 to 158 )
Weight
4,950g
Installation
19" Rack mounting and wall mounting
Storage Temperature
-40 to 85(-40 to 185 )
19
Ambient Relative Humidity
5% to 95% (non-condensing)
APPROVALS
Industry
Safety
UL 60950-1, IEC 60950-1, CCC
EMI
FCC 47 CFR Part 15 Subpart B Class A, IEC 61000-6-4, EN 55022(CISPR 22), EN 55032
EMS(IEC 61000-6-2)
IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11, IEC 61000-4-29
Environmental Type Tests
Cold Temperature:
IEC 60068-2-1
Dry Heat:
IEC 60068-2-2
Humidity:
IEC 60068-2-30
Shock:
IEC 60255-21-2
Freefall:
IEC 60068-2-32
Vibration:
IEC 60068-2-6
Hi-Pot:
1.5KV
Ordering Information
Product Port Combination Interface
Combo Port
Model Name
Operating
Temperature
10/100/1000Base-T and 100/1000Base-
SFP
DVS-328R02-8SFP -25 to 70 4 4 20 1 1 3
Optional Products
LCP Series: 100Base-FX/1000Base-X SFP Fiber Transceiver CliQII/PMC Series: 48V
Industrial Power Supply
DC
Combo Port
10/100Base-T(X)
and 100Base-SFP
10/100
Base-T(X)
DI
DO
(Relay)
Power
Input
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
20
Industry
DVS-110 series
Managed Industrial 7-Port FE + 3-Port GbE Combo 100/1000Base-SFP Ethernet Switches
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
IPv6 address suitable for larger network and
neighbor discovery
Automatic IP assignment by DHCP/BootP server
for easy network construction
DHCP relay option 82 for sending DHCP requests
with clients’ identities to a DHCP server
SNMP v1/v2c/v3 facilitates the exchange of
management between network devices
Supports MODBUS TCP protocols that facilitate
the remote management by SCADA and other
industrial devices
STP/RSTP/MSTP for network redundancy further
ensures reliability
QoS (IEEE 802.1p) and TOS/DSCP for mission-
critical applications
IEEE 802.1Q VLAN and GVRP optimize network
strategy
Enhanced network security with IEEE 802.1X,
TACACS+, SSH, HTTPS and SNMP v3
IEEE 802.3ad port trunking in parallel to increase
the link bandwidth
SNTP (simple network time protocol) for network
clock synchronization
Broadcast/Multicast/Unknown Unicast storm
control improves throughput problems
Intelligent Access Control List (ACL)
MAC addresses locking function per port blocks
unauthorized access
USB console interface for easy connection with
laptops
IGMP Snooping and GMVP prunes multicast trafc
RMON groups 1, 2, 3, 9 (history, statistics, alarms
and events) for enhanced ow management and
analysis
CPU utilization displays the amount of work the
CPU handles
Port mirroring for Many-to-One ports online
troubleshooting
Versatile system le updates by TFTP, HTTPS or
HTTP
DDM diagnosis function by SFP ber module
Auto warning by email, DI, relay, Syslog & SNMP
trap
Compatible with various industrial protocols,
including EtherNet/IP, Pronet, CC-LINK IE and
DNP 3.0
Specications
TECHNOLOGY
Standard Compliance
• IEEE 802.3 10Base-T
• IEEE 802.3u 100Base-T(X) and 100Base-FX
• IEEE 802.3ab 1000Base-T
• IEEE 802.3z 1000Base-X
• IEEE 802.3x Flow Control
• IEEE 802.1D Spanning Tree Protocol
• IEEE 802.1w Rapid Spanning Tree Protocol
• IEEE 802.1s Multiple Spanning Tree Protocol
• IEEE 802.1p Class of Service, Priority Protocols
• IEEE 802.1Q VLAN Tagging
• IEEE 802.1X Port Authentication
• IEEE 802.3ad LACP Aggregation
• IEEE 802.1AB Link Layer Discovery Protocol
21
Processing Type
• Store and Forward
IEEE 802.3x ow control in
full duplex, back-pressure ow
control in half duplex
INTERFACE
Industry
Fast Ethernet
RJ45 Ports:
• 10/100Base-T(X), auto MDI/MDI-X, auto negotiation
Gigabit Ethernet Combo Ports
RJ45 Ports:
• 10/100/1000Base-T, auto MDI/MDI-X, auto negotiation
SFP Ports:
• 100/1000Base-SFP
Console Port
• USB B-Type connector
LEDs
Device:
• ALARM, PWR1, PWR2, DI1, DI2
Ports:
• 100/1000M (SFP port), 10/100/1000M (GbE RJ45 port), 10/100M (FE RJ45 port), LINK/
ACT
Digital Inputs (DI)
• 2 sets
• 0~+5V is OFF
• +11V~30V is ON
• Max. input current 6mA
PERFORMANCE AND SCALABILITY
Switching Capacity
• 7.4Gbps, wire-speed, non-blocking switching fabric
Forwarding Rate
• 11Mpps
MAC Address Table
• 8K
Packet Buffer Memory
• 512K bits
IGMP Multicast Groups
• 256
Max. VLANs
• 255
MANAGEMENT
Software
• STP/RSTP/MSTP, LACP, QoS, IGMP Snooping v1/v2/v3, IGMP Query v1/v2, GARP, GMRP, VLAN, SSH, DNS, HTTP, HTTPS, RADIUS, TACACS+, SNMP v1/v2c/v3, SNMP Traps, TFTP, RMON, LLDP, BootP Server/Client, DHCP Server/Client, DHCP L2 Relay, DHCP Relay Option 82, DHCP Option 66/67, Telnet, Syslog, SMTP, SNTP Server/ Client, IPv6, MODBUS TCP
Security
MAC/IP/TCP/UDP ltering, HTTPS, SSH, 802.1X, TACACS+, SNMP v3
Alarm Contacts (DO)
• 2 relay outputs
• Carry current 2A@24V
DC
Reset Button
• 1 set
Quality of Service
• 8 priority queues per port
DHCP/BootP Server
• 1275 IP addresses
Jumbo Frame
• 9,216 Bytes
Conguration
• Web Browser, Cisco-like Telnet CLI, USB Local Console, SNMP, MODBUS TCP, IEXplorer Utility
MIB
• MIB II, Bridge MIB, SNMP MIB, Ether-like MIB, Q-Bridge/P-Bridge MIB, IF MIB, Traceroute MIB, TCP MIB, UDP MIB, IP MIB, RMON Group 1, 2, 3, 9, Delta Private MIB
Ethernet Switches
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
POWER REQUIREMENTS
Input Voltage
• 2 sets, 12 to 48 VDC redundant terminal block input
lnput Current
• Max. 0.95A
PHYSICAL
Housing
• IP40 metal case
Dimensions
• 145.3 mm (H) x 75 mm (W) x 108.7 mm (D)
ENVIRONMENTAL LIMITS
Operating Temperature
• -40℃ to 75℃ (-40˚F to 167˚F)
Overload Current Protection
• Present, max. input current 3A
Reverse Polarity Protection
• Present
Weight
• 564g
Installation
• Industrial DIN-Rail and wall mounting
Storage Temperature
• -40℃ to 85℃ (-40˚F to 185˚F)
22
Buffer Time
• Min. 12ms at 24V
DC
Ambient Relative Humidity
• 5% to 95% (non-condensing)
Industry
APPROVALS
Safety
• UL 508, EN 60950-1, IEC 61131-2
EMI
Ethernet Switches
• FCC 47 CFR Part 15 Subpart B Class A, IEC 61000-6-4, EN 55022(CISPR22)
EMS [IEC 61000-6-2
• IEC 61000-4-2 level 3, IEC 61000-4-3 level 3, IEC 61000-4-4 level 4, IEC 61000-4-5 level 3, IEC 61000-4-6 level 3, IEC 61000-4-8 level 4, IEC 61000-4-29
Ordering Information
IEEE 802.11 WLAN IIoT Routers Ethernet Converters
Model Name
DVS-110W02-3SFP -40℃ to 75
Optional Products
LCP Series: 100Base-FX/1000Base-X SFP Fiber Transceiver
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply
Freefall:
• IEC 60068-2-32
Vibration:
• IEC 60068-2-6
Hi-Pot:
• 1.5KV
, EN 55024(CISPR24)]
Environmental Type Tests
Cold Temperature:
• IEC 60068-2-1
Dry Heat:
• IEC 60068-2-2
Humidity:
• IEC 60068-2-30
Shock:
• IEC 60255-21-2
Product Port Combination Interface
Operating
Temperature
Combo Port
10/100/1000Base-T
and 100/1000Base-SFP
3 --- 7 2 2 2
10/100/1000
Base-T
10/100
Base-T(X)
DI
DO
(Relay)
Power
Input
23
Loading...