Air Pressure (IN H
O)
( 80/110 CFM)
Full Speed:
80 CFM/<0.3 Sones @ 0.1” SP, 6.2 Watts 80 CFM/0.5 Sones @ 0.25” SP, 9.9 Watts
Full Speed:
110 CFM/<0.3 Sones @ 0.1” SP, 8.2 Watts 110 CFM/0.8 Sones @ 0.25” SP, 14.1 Watts
Description
Low noise ceiling mount ventilating fan rated for continuous running. Fan has been awarded ENERGY STAR® Most Ecient
2018. It is HVI, UL, and cUL certied to comply with ASHRAE
62.2 local and whole building continuous and intermittent operation. Meets CA Title 24 requirements.
DC Motor/Blower
• Power rating of 120 volts/60Hz
• Brushless DC motor engineered to run continuously
• Motor equipped with thermal cuto fuse
• Removable with permanently lubricated plug-in motor
• Full speed adjustable, 80 or 110 CFM
• Built-in soft start function to increase bearings’ life
• Automatically powers OFF when impeller is locked abnormally
• Self-compensating motor speed for intended airow when static pressure is encountered
Housing
• Galvanized steel body
• Detachable 6” diameter metal duct adapter
• Includes 6” to 4” duct reducer
• Built-in backdraft damper
• Easy installation with expandable extension bracket
Grille
• Attractive design using ABS material
• Attaches directly to housing with torsion springs
LED Indicator
• Turn the power switch on/o to operate on/o. LED indicator will be green when power is on
Warranty
• 3-Year limited warranty
BreezSignature SIG80-110
Static Pressure (Inches w.g.) 0.1 0.25 0.1 0.25
Air Flow (CFM) 80 80 110 110
Sones <0.3 0.5 <0.3 0.8
Power Consumption (Watts) 6.2 9.9 8.2 14.1
Energy Eciency (CFM/Watts) 15.4 9.0 15.3 8.7
Current (Amps) 0.38 Max
Power Rating (V/Hz) 120/60
TYPICAL SPECIFICATION
Ventilation fan shall be Delta Breez model SIG80-110; ENERGY STAR qualied with Brushless DC Motor engineered to run continuously for a minimum 70,000 hours; airow rating of 110 CFM and loudness rating of <0.3 Sones at 0.1” static pressure as certied by the Home Ventilating Institute (HVI); power consumption of 8.2 Watts with eciency rating of
15.3 CFM/Watt at 0.1” static pressure; fan will feature motor lock protection and self-compensating motor speed for intended airow when static pressure is encountered. UL and cUL listed for tub/shower enclosure when used with GFCI-protected branch circuit wiring.
4”
6”
Adapter
7 7/8
9 5/8
"
12 3/8
9 5/8
"
"
"
12 3/8
SIG80-110 Fan Curve
0.90
0.80
0.70
0.60
2
0.50
0.40
0.30
0.25
0.20
0.10
0
0 30.0 60.0 90.0 120.0 150.0
Air Flow (CFM)
80CFM
Low Speed
110CFM
Low Speed
80ft 60ft 40ft 20ft
Model Quantity Comments Project:
Location: Architect: Engineer: Contractor: Submitted by: Date:
46101 Fremont Blvd. Fremont, CA 94538 | tel 1.888.979.9889 | www.deltabreez.com
Loading...