1
Last Update ALLU 18/05/2016
NORTH AMERICAN EDITION
HEADQUARTERS - www.deltalight.com - USA - www.deltalight.us - CANADA - www.deltalight.ca
Installation instruction
IMAX® WALLWASH XR13
Application
Ceiling recessed
Finishing section to be used with DELTA LIGHT
®
rough-in housing or plasterframe
and iMAX® cover
For indoor use only
Ceiling Thickness
For 5/8” ceiling standard up to 7/8”
Light Source
1x powerled white 11W
Connector
Housing and trim connection through snap-in connector
Power Supply
Current controlled class 2 power supply required. (supplied with housing)
Max 500mA, typical forward voltage 22V. Do not interconnect in parallel!
Product Description
Surface treated aluminum construction
Suitable for dry and damp location
Protected against solid objects greater than 12mm IP20
Weight: 0,9lbs 0,4kg
Dimensions
Recessed dept: 135mm = 5”-5/16
Height: 127mm = 5”
Ceiling Cut out: Ø133mm = 5”-1/4
Required Accessories
iMAX® COVER ROUND WALLWASH 400 00 41
= B-B / B-MMAT / W-W / W-B / W-MMAT
IC
AT
Conforms to ANSI/UL Std. 1598
Cert. to CAN/CSA Std. 22.2 No. 250.0
Required options for non-class 2 power limited circuits for
iMax WALLWASH XR13 9XXX
Housing for IC and/or airtight applications
Required options for non-class 2 power limited circuits for
iMax WALLWASH XR13 8XXX
Housing for IC and/or airtight applications
127mm
5”
01 - NIC Plasterframe S
01 - NIC Plasterframe S
01 - NIC Plasterframe S
01 - NIC Plasterframe S
01 - NIC Plasterframe S
01 - NIC Plasterframe S
6
6
6
6
6
6
202
202
202
202
202
202
45 - 500mA-DC 25W ED1
62 - 500mA-DC 12W ED8
73 - 500mA-DC 19W ED10
45 - 500mA-DC 25W ED1
62 - 500mA-DC 12W ED8
73 - 500mA-DC 19W ED10
1 - 120V / 2 - 277V
1 - 120V
1 - 120V / 2 - 277V
1 - 120V / 2 - 277V
1 - 120V
1 - 120V / 2 - 277V
1 - Bar hangers standard
1 - Bar hangers standard
1 - Bar hangers standard
1 - Bar hangers standard
1 - Bar hangers standard
1 - Bar hangers standard
0 - No bar hangers
1 - Bar hangers standard
1 - 120V
2 - 277V
3 - 120-277V
Range
Installation
type
Lamp Source Opening
Voltage Mounting Option
46 - PK170
46 - PK170
46 - PK170
69 - EMP R98
69 - EMP R98
69 - EMP R98
2 - IC AT Housing M
2 - IC AT Housing M
2 - IC AT Housing M
2 - IC AT Housing M
2 - IC AT Housing M
2 - IC AT Housing M
6
6
6
6
6
6
202
202
202
202
202
202
45 - 500mA-DC 25W ED1
62 - 500mA-DC 12W ED8
73 - 500mA-DC 19W ED10
45 - 500mA-DC 25W ED1
62 - 500mA-DC 12W ED8
73 - 500mA-DC 19W ED10
3 - 120-277V
1 - 120V
3 - 120-277V
3 - 120-277V
1 - 120V
3 - 120-277V
1 - Bar hangers standard
1 - Bar hangers standard
1 - Bar hangers standard
1 - Bar hangers standard
1 - Bar hangers standard
1 - Bar hangers standard
0 - No bar hangers
1 - Bar hangers standard
1 - 120V
2 - 277V
3 - 120-277V
Range
Installation
type
Lamp Source Opening
Voltage Mounting Option
46 - PK170
46 - PK170
46 - PK170
69 - EMP R98
69 - EMP R98
69 - EMP R98
500mA (CRI>90)500mA (CRI>90)
IMAX® WALLWASH XR13 93543
6 404 11 13 952
IMAX® WALLWASH XR13 93043
6 404 11 13 932
IMAX® WALLWASH XR13 92743
6 404 11 13 922
NIC

Installation instruction
IMAX® WALLWASH XR13
2
NORTH AMERICAN EDITION
HEADQUARTERS - www.deltalight.com - USA - www.deltalight.us - CANADA - www.deltalight.ca
A
B
A
B
SAVE!
B
A
Accessories
INSTALLATION LUMINAIRE
Part no. 6 300 92 91 03 supplied
with the rough-in housing or plasterframe
32
RED = 3
BLACK = 2
1123
RED = 3
BLACK = 2
2
IC
AT
HOUSING
Not Supplied
Rough-in
Housing/Plasterframe
Required
1
343
5
NIC
PLASTERFRAME

Installation instruction
3
NORTH AMERICAN EDITION
HEADQUARTERS - www.deltalight.com - USA - www.deltalight.us - CANADA - www.deltalight.ca
IMAX® WALLWASH XR13
INSTALLATION LUMINAIRE
FOR MAINTENANCE
7
6
CEILING
WALL
MIN: 110mm
!
WALL
The light source contained in this luminaire
shall only be replaced by the manufacturer or
his service agent or a similar qualified person.