Delta Electronics PG-05 User Manual

2
PG-05
Pulse Generator Card for VFD-V Series
Instruction Sheet
1-1 PG-05 Appearance
2007-07-16
5011626802-G5E
1-3 Wiring Examples
Wiring Diagram 1
Non-Fuse breaker
NFB
R
S
T
FWD/STOP
REV/STOP Multi-step1
Factory Default
Multi-step2
Multi-step3
Multi-step4 Reset
E.F.
Digital common
Hand wheel
MPG
10-08 10-12
Line driver
-
+1
R/L1
S/L2
T/L3
24V FWD REV MI1 MI2 MI3 MI4 MI5 MI6 DCM
VP
A2 A2 B2 B2 DCM
Jumper
+2/B1
The Output Types
of the Encoder
Voltage 50m
Max. Wire
Length
1.25mm
Wire Gauge
2
(AWG18) or above
Open Collector 50m
Braking Resistor(Option)
B2
U/T1
V/T2
W/T3
U
V
W
Motor
M
3~
1-5 Installation
Line Driver 300m
Complementary 70m
1.25mm
2
(AWG18) or above
For 1-5HP For 7.5 HP and above
VP
Multi-functi on input terminals
DCM
A1 A1 B1 B1 Z1 Z1
Incremental encoder
PG
Line driver
Step 1: Insert 3 PCB supports into control board.
Step 2: Press the PG card on the control board to be fixed to tighten the 3
AO AO BO BO ZO ZO
screws with a torque of 4-6kgf-cm. If the PG card is not fixed on the control board, it may cause screw idle running and cannot turn the screw into supports.
1-2 Explanations of the Terminals of PG-05 Card
Terminals Explanation
VP
DCM Common point of the power supply and the signal
A1, B1,
B1
Z1,
Z1
A2, B2,
B2
AO, BO, ZO,
Output voltage of encoder: +5V±5% 200mA
The input signal of encoder (select output type of the encoder
A1
from FJP1). The power supply can be single-phase or 2-phase. It can be up to 500KP/Sec (max.).
Pulse (hand wheel and PLC) input (select input type from FJP4).
A2
The power supply can be single-phase or 2-phase. It can be up to 500KP/Sec (max.).
AO
The output signal of encoder can set the dividing frequency by using parameter 10-20.
BO
The Max. output of Line drive is 50mA.
ZO
Main circuit (power) terminals
Control circuit terminals
Shielded leads & Cable
Wiring Diagram 2
Non-Fus e breaker
R
S
T
FWD/STOP REV/STOP
Multi-step 1
Factory Default
Multi-step2 Multi-step 3
Multi-step4 Reset
E.F.
Digita l common
EH-PLC
Phase difference
Main circuit (power) terminals
1-4 Wiring Notes
NFB
Y0 Y0 Y1 Y1
COM
Jumper
-
+1
R/L1
S/L2
T/L3
24V FWD REV Mi1 Mi2 Mi3 Mi4 Mi5 Mi6 DCM
Y0 Y0
Y1 Y1
A2 A2 B2 B2 DCM
o
90
Control circuit terminals
Braking Resistor(Option)
+2/B1
B2
U/T1
V/T2
W/T3
VP
Multi-function input terminals
DCM
A1 A1 B1 B1 Z1 Z1
AO AO BO BO ZO ZO
U
V
W
Motor
M
3~
PG
Line driver
Incremental encoder
Shielded leads & Cable
1. Using the shielded wire to prevent interference, and do not line up in parallel with circuits of AC200V or above.
2. Recommended wire size: 0.21~0.81mm
3. Wire length (It is inversely proportional with signal frequency).
2
(AWG24~AWG18).
1-6 The Corresponding Output Types of Encoder
Output Types of the
Encoder
VCC
O/P
Voltage
0V
VCC
O/P
Open
Collector
Line
Driver
VCC
0V
Q
Q
O/P
0V
Complementary
FJP1 FJP2
TP
oc
TP
oc
TP
oc
TP
oc
TP
oc
TP
oc
TP
oc
TP
oc
Loading...