Delta Electronics PG-04 User Manual

PG-04
A2A
Pulse Generator Card for VFD-V Series
Instruction Sheet
1-1 PG-04 Appearance
O u
t p
u
V P
t t
e r
m i
n a l
Input terminal
CH1
A1A1B1
Z1
B1
Z1
Pulse input terminal
Power
VP
2 B2
CH2
B2
1-2 Explanations of the terminals of PG-04 Card
VP
Output voltage of encoder: +12V±5% 200mA
DCM Common point of the power supply and the signal
A1,
A1
B1
B1,
Z1
Z1,
A2,
A2
B2
B2,
A/O, B/O,
Z/O
The input signal of encoder (select output type of the encoder from FJP1) The power supply can be single-phase and 2-phase and the Max. is 500KP/Sec.
The input signal of encoder (select output type of the encoder from FJP4) The power supply can be single-phase and 2-phase and the Max. is 500KP/Sec.
The output signal of encoder can set the dividing frequency by using parameter 10-20. The Max. output of Open Collector is DC24V 100mA.
Grounding
1
1-3 Wiring Notes
1. Using the shielded wire to prevent interference, and do not line up in parallel with
circuits of AC200V or above.
2. Recommended wire size: 0.21~0.81mm
3. Wire length
The Output Types of the Encoder Max. Wire Length Wire Gauge
2
(AWG24~AWG18).
Voltage 50m
1.25mm
2
(AWG18) or above
Open Collector 50m
Line Driver 300m
2
1.25mm
(AWG18) or above
Complementary 70m
2
Loading...