Delphi Series H48SR, 200W Half Brick Family
DC/DC Power Modules: 48V in, 1.8V/80A out
The Delphi Series H48SR Half Brick, 48V input, adjustable single
output, isolated, open frame DC/DC converters are the latest offering
from a world leader in power systems technology and manufacturing —
Delta Electronics, Inc. This product family provides up to 200 watts o
power or up to 80A of output current in an industry standard footprint.
This product represents the next generation of design technology which
may be utilized to provide high levels of current at very low output
voltages required by today’s leading-edge circuitry. Utilizing an
advanced patented thermal and electrical design technology, the Delphi
Series H48SR converters are capable of providing much higher output
current capability with excellent transient response and lower common
mode noise. Featuring a wide operating output voltage range and high
current at low output voltages, these units offer more useable powe
over a wide range of ambient operating conditions. The wide range
trimmable output feature allows the user to both reduce and
standardize part numbers across different and/or migrating voltage
requirements.
OPTIONS
Short lead lengths
Latching/non-latching over voltage
protection
Positive/negative trim
Positive/negative remote on/off
100V/100ms transient capability or
80V input OVLO
APPLICATIONS
Telecom/DataCom
Wireless Networks
Optical Network Equipment
Server and Data Storage
Industrial/Test Equipment
DATASHEET
DS_H48SR1R880_06272006
1
Delta Electronics, Inc.
Page 2
TECHNICAL SPECIFICATIONS
r
(TA=25°C, airflow rate=300 LFM, V
PARAMETER
ABSOLUTE MAXIMUM RATINGS
Input Voltage
Continuous
Transient (100ms) 100ms 100 Vdc
Operating Device Temperature Tc -40 115 °C
Storage Temperature
Input/Output Isolation Voltage 1 minute 1500 Vdc
INPUT CHARACTERISTICS
Operating Input Voltage
Input Under-Voltage Lockout
Turn-On Voltage Threshold
Turn-Off Voltage Threshold
Lockout Hysteresis Voltage
Maximum Input Current 100% Load, 36Vin 5 A
No-Load Input Current 100 140 mA
Off Converter Input Current 15 25 mA
Inrush Current(I2t) 0.03 A2S
Input Reflected-Ripple Current
Input Voltage Ripple Rejection 120 Hz 60 dB
OUTPUT CHARACTERISTICS
Output Voltage Set Point Vin=48V, Io=Io.max, Tc=25°C 1.75 1.8 1.85
Output Voltage Regulation
Over Load Io=Io,min to Io,max ±2 ±7 mV
Over Line Vin=36V to 75V ±2 ±5 mV
Over Temperature Tc=-40°C to 100°C ±20 ±50 mV
Total Output Voltage Range over sample load, line and temperature TBD TBD V
Output Voltage Ripple and Noise 5Hz to 20MHz bandwidth
Peak-to-Peak Full Load, 1µF ceramic, 10µF tantalum 70 120 mV
RMS Full Load, 1µF ceramic, 10µF tantalum 20 40 mV
Operating Output Current Range 0 80 A
Output DC Current-Limit Inception Output Voltage 10% Low 105 130 %
DYNAMIC CHARACTERISTICS
Output Voltage Current Transient 48V, 10µF Tan & 1µF Ceramic load cap, 0.1A/µs
Positive Step Change in Output Current 50% Io,max to 75% Io,max 50 100 mV
Negative Step Change in Output Current 75% Io,max to 50% Io,max 50 100 mV
Settling Time (within 1% Vout nominal) 200 uS
Turn-On Transient
Start-Up Time, From On/Off Control 10 20 mS
Start-Up Time, From Input -40°C to +125°C 20 40
Maximum Output Capacitance Full load; 5% overshoot of Vout at startup 20000 µF
Switching Frequency 240 kHz
ON/OFF Control, (Logic Low-Module ON)
Logic Low Von/off at Ion/off=1.0mA 0 0.8 V
Logic High Von/off at Ion/off=0.0 µA 15 V
ON/OFF Current Ion/off at Von/off=0.0V 1 mA
Leakage Current Logic High, Von/off=15V 50 uA
Output Voltage Trim Range Across Pins 9 & 5, Pout <= max rated powe
Output Voltage Remote Sense Range Pout <= max rated power 10 %
Output Over-Voltage Protection Over full temp range; % of nominal Vout 115 130 155 %
GENERAL SPECIFICATIONS
MTBF Io=80% of Io, max; Ta=25°C,airflow rate=300 LFM1.41 M hours
Weight 66 grams
Over-Temperature Shutdown Power Region Temperature 130 °C
=48Vdc, nominal Vout unless otherwise noted.)
in
NOTES and CONDITIONS H48SR1R880NRFA
P-P thru 12µH inductor, 5Hz to 20MHz 10 mA
89 %
Min. Typ. Max. Units
80 Vdc
-55 125 °C
36 48 75 Vdc
32.5 34 35 Vdc
31 32 33.5 Vdc
1 2 3 Vdc
0.8 1.9 V
Vdc
mS
DS_H48SR1R880_06272006
2
Page 3
ELECTRICAL CHARACTERISTICS CURVES
95
36Vin48Vin75Vin
90
85
EFFICIENT (%)
80
75
70
65
60
1020304050607080
OUTPUT CURRENT (A)
Figure 1: Efficiency vs. load current for minimum, nominal, and
maximum input voltage at 25°C. (Vout=1.8V)
90
85
24.0
36Vin48Vin75Vin
20.0
16.0
POWER DISSIPATION (W)
12.0
8.0
4.0
0.0
1020304050607080
OUTPUT CURRENT(A)
Figure 2: Power dissipation vs. load current for minimum,
nominal, and maximum input voltage at 25°C. (Vout=1,8V)
24.0
36Vin48Vin75Vin
20.0
EFFICIENT (%)
80
75
70
65
36Vin48Vin75Vin
60
1020304050607080
OUTPUT CURRENT (A)
Figure 3: Efficiency vs. load current for minimum, nominal, and
maximum input voltage at 25°C. (Vout=0.8V)
16.0
POWER DISSIPATION (W)
12.0
8.0
4.0
0.0
1020304050607080
OUTPUT CURRENT(A)
Figure 4: Power dissipation vs. load current for minimum,
nominal, and maximum input voltage at 25°C. (Vout=0.8V)
DS_H48SR1R880_06272006
3
Page 4
ELECTRICAL CHARACTERISTICS CURVES
90
88
86
EFFICIENCY (%)
84
82
80
78
36Vin48Vin75Vin
76
0.81.01.21.41.61.8
OUTPUT VOLTAGE (V)
Figure 5: Efficiency vs. output voltage for minimum, nominal,
and maximum input voltage at 25°C. (Iout=80A)
6.0
Io=80AIo=48AIo=8A
5.0
24.0
22.0
20.0
POWER DISSIPATION (W)
18.0
16.0
14.0
12.0
36Vin48Vin75Vin
10.0
0.81.01.21.41.61.8
OUTPUT VOLTAGE (V)
Figure 6: Power dissipation vs. output voltage for minimum,
nominal, and maximum input voltage at 25°C. (Iout=80A)
4.0
INPUT CURREN (A)
3.0
2.0
1.0
0.0
30354045505560657075
INPUT VOLTAGE (V)
Figure 7: Typical input characteristics at room temperature Figure 8: Turn-on transient at full rated load current (resistive
load) (1 ms/div). Top Trace: Vout; 1V/div; Bottom Trace:
ON/OFF input: 2V/div
DS_H48SR1R880_06272006
4
Page 5
ELECTRICAL CHARACTERISTICS CURVES
A
A
)
)
Figure 9: Turn-on transient at zero load current (2 ms/div).
Top Trace: Vout: 1V/div; Bottom Trace: ON/OFF input:
2V/div
Figure 10: Output voltage response to step-change in load
current (75%-50%-75% of Io, max; di/dt = 0.1A/µs). Load cap:
10µF, tantalum capacitor and 1µF ceramic capacitor. Top Trace:
Vout (20 mV/div), Bottom Trace: Iout (20
measurement should be made using a BNC cable (length shorter
than 20 inches). Position the load between 51 mm to 76 mm (2
inches to 3 inches) from the module..
/div). Scope
Figure 11: Output voltage response to step-change in load
current (75%-50%-75% of Io, max: di/dt = 2.5A/µs). Load
cap: 470µF, 35m
ceramic capacitor. Top Trace: Vout (100mV/div), Bottom
Trace: Iout (20
using a BNC cable (length shorter than 20 inches
the load between 51 mm to 76 mm (2 inches to 3 inches
from the module.
Ω
/div). Scope measurement should be made
5
DS_H48SR1R880_06272006
ESR solid electrolytic capacitor and 1µF
. Position
Figure 12: Test set-up diagram showing measurement points for
Input Terminal Ripple Current and Input Reflected Ripple Current.
Note: Measured input reflected-ripple current with a simulated
source Inductance (L
battery impedance. Measure current as shown above.
) of 12 µH. Capacitor Cs offset possible
TEST
Page 6
ELECTRICAL CHARACTERISTICS CURVES
E
Figure 13: Input Terminal Ripple Current, i
, at full rated
c
output current and nominal input voltage with 12µH source
impedance and 33µF electrolytic capacitor (500 mA/div).
Copper Strip
Vo(+)
10u1u
SCOPERESISTIV
LOAD
Vo(-)
Figure 15: Output voltage noise and ripple measurement
test setup
2.0
1.8
1.6
1.4
1.2
OUTPUT VOLTAGE (V)
1.0
0.8
0.6
0.4
0.2
0.0
Vin= 48V
0 10 203040 5060708090100
LOAD CURRENT (A)
Figure 17: Output voltage vs. load current showing typical
current limit curves and converter shutdown points.
Figure 14: Input reflected ripple current, i
, through a 12µH
s
source inductor at nominal input voltage and rated load current
(5 mA/div).
Figure 16: Output voltage ripple at nominal input voltage and
rated load current (50 mV/div). Load capacitance: 1µF ceramic
capacitor and 10µF tantalum capacitor. Bandwidth: 20 MHz.
Scope measurement should be made using a BNC cable (length
shorter than 20 inches). Position the load between 51 mm to 76
mm (2 inches to 3 inches) from the module.
DS_H48SR1R880_06272006
6
Page 7
THERMAL CURVES
Output Current(A)
88
80
72
64
56
48
40
32
24
16
8
0
0 10203040506070809010011
Figure 18: Hot spot location (unit in mm) Figure 19: Output current vs. ambient temperature and air
velocity (Vin=48V / 75V, V
H48SR1R880(Standard) Output Current vs. Ambient Temperature and Ai r Velocity
Natural
Convection
@ Output Voltage 0.8V (Eit her Orientation)
100LFM
200LFM
=0.8V )
out
300LFM
600LFM
Ambient Temperature (℃)
500LFM
400LFM
0
Output Current(A)
88
80
72
64
56
48
40
32
24
16
8
0
0 1020304050607080 90100
H48SR1R880(Standard) Output Current vs. Ambient Temperature and Ai r Velocity
Natural
Convection
Figure 20: Output current vs. ambient temperature and air
velocity (Vin=48V / 75V, V
@ Output Voltage 1.8V (Eit her Orientation)
100LFM
200LFM
=1.8V )
out
600LFM
500LFM
400LFM
300LFM
Ambient Temperature (℃)
H48SR1R880(Standard) Power Dis sipation vs. Ambient Temperature and Air V elocity
Power Dissipation (Watts)
24
21
18
15
12
9
6
3
0
Natural
Convection
100LFM
0 102030 405060708090100110
Figure 21: Power dissipation vs. ambient temperature and air
velocity (Vin=48V / 75V, V
(Either Orientation)
200LFM
=0.8V~1.8V )
out
600LFM
500LFM
400LFM
300LFM
Ambient Temperature (℃)
DS_H48SR1R880_06272006
7
Page 8
DESIGN CONSIDERATIONS
Input Source Impedance
The impedance of the input source connecting to the
DC/DC power modules will interact with the modules
and affect the stability. A low ac-impedance input
source is recommended. If the source inductance is
more than a few µH, we advise adding a 10 to 100 µF
electrolytic capacitor (ESR < 0.7 Ω at 100 kHz)
mounted close to the input of the module to improve the
stability.
Layout and EMC Considerations
Delta’s DC/DC power modules are designed to operate
in a wide variety of systems and applications. For
design assistance with EMC compliance and related
PWB layout issues, please contact Delta’s technical
support team. An external input filter module is
available for easier EMC compliance design.
Application notes to assist designers in addressing
these issues are pending release.
Safety Considerations
The power module must be installed in compliance with
the spacing and separation requirements of the enduser’s safety agency standard, i.e., UL60950,
CAN/CSA-C22.2 No. 60950-00 and EN60950:2000 and
IEC60950-1999, if the system in which the power
module is to be used must meet safety agency
requirements.
When the input source is 60 Vdc or below, the power
module meets SELV (safety extra-low voltage)
requirements. If the input source is a hazardous voltage
which is greater than 60 Vdc and less than or equal to
75 Vdc, for the module’s output to meet SELV
requirements, all of the following must be met:
The input source must be insulated from any
hazardous voltages, including the ac mains, with
reinforced insulation.
One Vi pin and one Vo pin are grounded, or all the
input and output pins are kept floating.
The input terminals of the module are not operator
accessible.
If the metal baseplate is grounded the output must
be also grounded.
A SELV reliability test is conducted on the system
where the module is used to ensure that under a
single fault, hazardous voltage does not appear at
the module’s output.
Do not ground one of the input pins without grounding
one of the output pins. This connection may allow a
non-SELV voltage to appear between the output pin
and ground.
The power module has extra-low voltage (ELV) outputs
when all inputs are ELV.
This power module is not internally fused. To achieve
optimum safety and system protection, an input line
fuse is highly recommended. The safety agencies
require a normal-blow fuse with 20A maximum rating to
be installed in the ungrounded lead. A lower rated fuse
can be used based on the maximum inrush transient
energy and maximum input current.
Soldering and Cleaning Considerations
Post solder cleaning is usually the final board assembly
process before the board or system undergoes
electrical testing. Inadequate cleaning and/or drying
may lower the reliability of a power module and
severely affect the finished circuit board assembly test.
Adequate cleaning and/or drying is especially important
for un-encapsulated and/or open frame type power
modules. For assistance on appropriate soldering and
cleaning procedures, please contact Delta’s technical
support team.
8
DS_H48SR1R880_06272006
Page 9
n
FEATURES DESCRIPTIONS
Over-Current Protection
The modules include an internal output over-current
protection circuit, which will endure current limiting for
an unlimited duration during output overload. If the
output current exceeds the OCP set point, the modules
will automatically shut down (hiccup mode).
The modules will try to restart after shutdown. If the
overload condition still exists, the module will shut down
again. This restart trial will continue until the overload
condition is corrected.
Over-Voltage Protection
The modules include an internal output over-voltage
protection circuit, which monitors the voltage on the
output terminals. If this voltage exceeds the overvoltage set point, the module will shut down and latch
off. The over-voltage latch is reset by cycling the input
power for one second.
Over-Temperature Protection
The over-temperature protection consists of circuitry
that provides protection from thermal damage. If the
temperature exceeds the over-temperature threshold
the module will shut down.
The module will try to restart after shutdown. If the overtemperature condition still exists during restart, the
module will shut down again. This restart trial will
continue until the temperature is within specification.
Remote On/Off
The remote on/off feature on the module can be either
negative or positive logic. Negative logic turns the
module on during a logic low and off during a logic high.
Positive logic turns the modules on during a logic high
and off during a logic low.
Remote on/off can be controlled by an external switch
between the on/off terminal and the Vi(-) terminal. The
switch can be an open collector or open drain.
For negative logic if the remote on/off feature is not
used, please short the on/off pin to Vi(-). For positive
logic if the remote on/off feature is not used, please
leave the on/off pin floating.
Vo(+)Vi(+)
Sense(+)
ON/OFF
Sense(-)
Vi(-)
Vo(-)
Figure 22: Remote on/off implementation
Remote Sense
Remote sense compensates for voltage drops on the
output by sensing the actual output voltage at the point
of load. The voltage between the remote sense pins
and the output terminals must not exceed the output
voltage sense range given here:
This limit includes any increase in voltage due to
remote sense compensation and output voltage set
point adjustment (trim).
Vi(+)
Vo(+)
Sense(+)
Sense(-)
Vi(-)
Contact
Resistance
Vo(-)
Contact and Distributio
Losses
Figure 23: Effective circuit configuration for remote sense
operation
If the remote sense feature is not used to regulate the
output at the point of load, please connect SENSE(+)
to Vo(+) and SENSE(–) to Vo(–) at the module.
The output voltage can be increased by both the
remote sense and the trim; however, the maximum
increase is the larger of either the remote sense or the
trim, not the sum of both.
When using remote sense and trim, the output voltage
of the module is usually increased, which increases the
power output of the module with the same output
current.
Care should be taken to ensure that the maximum
output power does not exceed the maximum rated
power.
DS_H48SR1R880_06272006
9
Page 10
FEATURES DESCRIPTIONS (CON.)
Ω
Ω
Output Voltage Adjustment (TRIM)
To increase or decrease the output voltage set point,
the modules may be connected with an external
resistor between the TRIM pin and either the
SENSE(+) or SENSE(-). The TRIM pin should be left
open if this feature is not used.
Figure 24: Circuit configuration for trim-up (increase output
voltage)
If the external resistor is connected between the TRIM
and SENSE (+) pins, the output voltage set point
increases (Fig. 24). The external resistor value
required to obtain a percentage of output voltage
change △% is defined as:
upRtrim1110
⎢
⎣
⎡
()
=∆−kk
()
∆
ref
V
where
Vonom = nominal Vout (1.8V)
Vref = 1.225V
∆ = trim expressed as decimal fraction, i.e. 10% is written
as 0.1
Ex. When trim up to 1.9V from 1.8V
Vonom = 1.8V
Vref = 1.225V
∆ = (1.9-1.8)/1.8 = 0.05556
()()
[]
=−
Ω=Ω−
KK
18.8811
05556.0*225.1
⎤
−∆+
refonom
V1V
⎥
⎦
−
225.105556.1*8.1
10
Ω−Ω
Ω×
KupRtrim
Figure 25: Circuit configuration for trim-down (decrease
output voltage)
If the external resistor is connected between the TRIM
and SENSE (-) the output voltage set point decreases
(Fig. 25). The external resistor value required to obtain
a percentage output voltage change △% is defined
as:
k
10
()
downRtrim11
where
Vonom = nominal Vout (1.8V)
∆ = trim expressed as decimal fraction, i.e. 40% is
written as 0.4
=∆−k
∆
Ω−
Ex. When trim down to 0.8V from 1.8V
Vonom = 1.8V
∆ = (1.8-0.8)/1.8 = 0.5556
K
downRtrim711
10
Ω=Ω−=−KK
5556.0
The output voltage can be increased by both the remote
sense and the trim, however the maximum increase is
the larger of either the remote sense or the trim, not the
sum of both.
When using remote sense and trim, the output voltage
of the module is usually increased, which increases the
power output of the module with the same output
current.
Care should be taken to ensure that the maximum
output power of the module remains at or below the
maximum rated power.
Output voltage
1.5V 49.00
1.2V 19.00
1.0V 11.50
0.9V 9.0
0.8V 7.0
Figure 26: Trim resistor value example for popular output
Resistor value (
k)
DS_H48SR1R880_06272006
10
Page 11
A
)
Y
THERMAL CONSIDERATIONS
Thermal management is an important part of the
system design. To ensure proper, reliable operation,
sufficient cooling of the power module is needed over
the entire temperature range of the module. Convection
cooling is usually the dominant mode of heat transfer.
Hence, the choice of equipment to characterize the
thermal performance of the power module is a wind
tunnel.
Thermal Testing Setup
Delta’s DC/DC power modules are characterized in
heated vertical wind tunnels that simulate the thermal
environments encountered in most electronics
equipment. This type of equipment commonly uses
vertically mounted circuit cards in cabinet racks in which
the power modules are mounted.
The following figure shows the wind tunnel
characterization setup. The power module is mounted
on a test PWB and is vertically positioned within the
wind tunnel. The space between the neighboring PWB
and the top of the power module is constantly kept at
6.35mm (0.25’’).
Thermal Derating
Heat can be removed by increasing airflow over the
module. The module’s maximum device temperature is
115 ℃ and the measured location is illustrated in Figure
18. To enhance system reliability, the power module
should always be operated below the maximum
operating temperature. If the temperature exceeds the
maximum module temperature, reliability of the unit
may be affected.
FACING PWB
AIR VELOCIT
AND AMBIENT
TEMPERATURE
MEASURED BELOW
THE MODULE
Note: Wind Tunnel Test Se tup Fig u r e Dimensions are in millimeters an d (In che s )
Figure 27: Wind Tunnel Test Setup
PWB
MODULE
50.8 (2.0”
IR FLOW
12.7 (0.5”)
DS_H48SR1R880_06272006
11
Page 12
MECHANICAL DRAWING
Pin No. Name Function
1
2
3
4
5
6
7
8
Notes:
1
2
3
DS_H48SR1R880_06272006
-Vin
ON/OFF
+Vin
+Vout
+SENSE
TRIM
-SENSE
-Vout
Pins 1-3, 5-7 are 1.00mm (0.039”) diameter
Pins 4 and 8 are 2.00mm (0.079”) diameter
All pins are copper with Tin plating.
Negative input voltage
Remote ON/OFF
Positive input voltage
Positive output voltage
Positive remote sense
Output voltage trim
Negative remote sense
Negative output voltage
12
Page 13
PART NUMBERING SYSTEM
H 48 S R 1R8 80 N R F A
Form
Factor
H- Half Brick 48-
Input
Voltage
36V~75V
Number of
Outputs
S- Single R- Single
Product
Series
Board
Output
Voltage
1R8- 1.8V80- 80AN- Negative
Output
Current
ON/OFF
Logic
P- Positive
Pin
Length
R- 0.170”
N- 0.145”
K- 0.110”
Option Code
F- RoHS 6/6
(Lead Free)
A - Standard
Functions
MODEL LIST
Part Number INPUT OUTPUT EFF @ 100% LOAD
H48SR1R860NRFA 36V~75V
H48SR1R880NRFA 36V~75V 5.0A 0.8V – 1.9V 80A 89%
H48SR3R360NRFA 36V~75V 6.4A 1.45V – 3.6V 60A 90%
3.7A
Please contact us for modules with fixed output voltages.
CONTACT:
USA:
Telephone:
East Coast: (888) 335 8201
West Coast: (888) 335 8208
Fax: (978) 656 3964
DCDC@delta-corp.com
Email:
www.delta.com.tw/dcdc
Europe:
Telephone: +41 31 998 53 11
Fax: +41 31 998 53 53
DCDC@delta-es.tw
Email:
WARRANTY
Delta offers a two (2) year limited warranty. Complete warranty information is listed on our web site or is available upon
request from Delta.
Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for
its use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license is
granted by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these
specifications at any time, without notice