(INCH)
UNIT:
mm
(M3/MIN)
INLET SIDEOUTLET SIDE
(mm H
2
O)
(IN H
2
O)
mm
(INCH)
UNIT:
UH
GFB0612XU
3.60
3.00
2.40
1.80
1.20
0.60
0
Air Pressure
45.0
0
15.0
30.0
60.0
75.0
90.0
Air Flow
0 24.0 48.0 72.0 96.0
(CFM)
2.801.68 2.241.120.560
57.2
50.0
(2
.
2
5
2
)
(1
.
9
6
9
)
57.2
50.0
ø63.2
(
ø2.48
8)
57.2
50.0
(2
.
2
5
2
)
(
1
.
9
6
9
)
(1.969)
(2.252)
57.2
50.0
(1.969)
(2.252)
ø
65
.
2
(
ø
2
.56
7
)
(4-ø0.177)
4-ø4.5
(4-ø0.177)
4-ø4.5
LABEL
(2.362±0.020)
(1.969±0.012)
50.0±0.3
60.0±0.5
50.0±0.3
60.0±0.5
(2.362±0.020)
(1.969±0.012)
50.8±0.530.0±0.5
(1.181±0.020) (2.000±0.020)
2-4.0±0.3 2-4.0±0.3
(2-0.157±0.012) (2-0.157±0.012)
360.0±10.0
(14.173±0.394)
10.0
(0.394)
8-ø4.5±0.3
(8-ø0.177±0.012)
GFB
■
DIMENSIONS DRAWING
■
P & Q CURVE
(AT RATED VOLTAGE)
■
MOUNTING PANEL CUTOUT
60 x 60 x 89 MM SERIES
*
Bearing Type
Ball Bearings
*
Material
Impeller & Frame : Plactic (UL 94V-0)
*
Lead Wires :
UL 1061 AWG #24 OR Equivalent
Red And Orange Wire Positive (+)
Black And Brown Wire Negative(-)
*
Weight : 255g (8.99 OZ)
MODEL
Rated
Voltage
Operating
Voltage
Range
Input
Current
Input
Power
Speed
(Front/Rear)
Maximum
Air Flow
Maximum
Air Pressure
Noise
PART NO. FUNCTION VDC VDC Amp Watt R.P.M. m3 /min CFM mmH2O IN H2O dB-A
GFB0612UHU -R00 / -F00 12 7.0 to 13.2 3.60 43.20 12200/12450 2.219 78.33 83.69 3.295 69.6
* Function type is optional.
* The max. air ow and the speed are measured in free air ; max. air pressure is measured at zero air ow.
* Noise is measured in anechoic chamber in free air, one meter from intake side.
* All readings are typical values at rated voltage.
* Specications are subject to change without notice.