Thank you very much for purchasing DELTA B Series. Please read this instruction sheet before using
your B series to ensure proper operation and please keep this instruction sheet handy for quick
reference.
1 Precaution
DANGER! Caution! Electric Shock!
1. Do not touch the AC terminals while the power is supplied to the controller to prevent an electric shock.
2. Make sure power is disconnected while checking the unit inside.
3. The symbol indicates that this Delta B Series Temperature Controller is protected throughout by DOUBLE
INSULATION or REINFORCED INSULATION (equivalent to Class II of IEC 536).
WARNING!
This controller is an open-type temperature controller. Make sure to evaluate any dangerous
application in which a serious human injury or serious property damage may occur.
1. Always use recommended solder-less terminals: Fork terminal with isolation (M3 screw, width is 7.0mm (6.0mm for
DTB 4824), hole diameter 3.2mm). Screw size: M3 x 6.5 (With 6.8 x 6.8 square washer). Screw size for DTB4824:
M3 x 4.5 (With 6.0 x 6.0 square washer). Recommended tightening torque: 0.4 N.m (4kgf.cm). Applicable wire:
Solid/twisted wire of 2 mm
2. Do not allow dust or foreign objects to fall inside the controller to prevent it from malfunctioning.
3. Never modify or disassemble the controller.
4. Do not connect anything to the “No used” terminals.
5. Make sure all wires are connected to the correct polarity of terminals.
6. Do not install and/or use the controller in places subject to:
• Dust or corrosive gases and liquid.
• High humidity and high radiation.
• Vibration and shock.
• High voltage and high frequency
7. Must turn power off when wiring and changing a temperature sensor.
8. Be sure to use compensating wires that match the thermocouple types when extending or connecting the
thermocouple wires.
9. Please use wires with resistance when extending or connecting a platinum resistance thermometer (RTD).
10. Please keep the wire as short as possible when wiring a platinum resistance thermometer (RTD) to the controller
and please route power wires as far as possible from load wires to prevent interference and induced noise.
11. This controller is an open-type unit and must be placed in an enclosure away from high temperature, humidity,
dripping water, corrosive materials, airborne dust and electric shock or vibration.
12. Please make sure power cables and signals from instruments are all installed properly before energizing the
controller, otherwise serious damage may occur.
13. Please do not touch the terminals in the controller or try to repair the controller when power is applied to prevent an
electric shock.
14. Wait at least one minute after power is disconnected to allow capacitors to discharge, and please do not touch any
internal circuit within this period.
15. Do not use acid or alkaline liquids for cleaning. Please use a soft, dry cloth to clean the controller.
16. This instrument is not furnished with a power switch or fuse. Therefore, if a fuse or power switch is required, install
the
rotection close to the instrument. Recommended fuse rating: Rated voltage 250 V, Rated current 1 A. Fuse
2
, 12AWG to 24AWG. Please be sure to tighten them properly.
1
type: Time-lag fuse
17. Note: This controller does not provide overcurrent protection. Use of this product requires that suitable overcurrent
protection device(s) must be added to ensure compliance with all relevant electrical standards and codes. (Rated
250 V, 15 Amps max). A suitable disconnecting device should be provided near the controller in the end-use
installation.
2 Display, LED and Pushbuttons
PV Display
SV Display
: to display the process value or parameter type.
: to display the set point, parameter operation read value,
manipulated variable or set value of the parameter.
Auto-tuning LED,
AT
: flashes when the Auto-tuning operation is ON.
OUT1/OUT2
Function key
: . Press this key to select the desired function mode and
: Output LED ights when the output is ON.
, l
confirm a setting value.
Mode key
: . Press this key to set parameters within function mode.
O
OOO
C, F : .
Temperature unit LED
C : Celsius F : Fahrenheit
ALM1 ~ ALM3 : Alarm output LED, lights when ALM1/ALM2/ALM3 is ON.
Down key
: . Press this key to decrease values displayed on the SV
display. Hold down this key to speed up the decrements.
:
Up
. Press this key to increase values displayed on the SV display.
key
Hold down this key to speed up the incremental action.
3
DTB
DTB Series
1 2 3 45 67
DTB : Delta B Series Temperature Controller
4824 : 1/32 DIN W48 × H24mm
1 2 3 4
Panel Size (W×H)
4848 : 1/16 DIN W48 × H48mm
4896 : 1/8 DIN W48 × H96mm
9696 : 1/4 DIN W96 × H96mm
R: Relay output, SPDT (SPST: 1/16 DIN and 1/32 DIN size), 250VAC, 5A
5
1st Output Group Selection
V: Voltage pulse output, 14V +10﹪~ -20﹪(Max. 40mA)
C: DC current output , 4 ~ 20m A
L: Linear voltage output, 0~5V, 0~10Vdc
6
2nd Output Group Selection
R: Relay output, SPDT (SPST: 1/16 DIN and 1/32 DIN size), 250VAC, 5A
V: Voltage pulse output, 14V +10﹪~ -20﹪(Max. 40mA)
None : No EVENT input , No CT (Current transformer)
7
EVENT Inputs / CT function
(Optional)
E: EVENT input is provided, No CT (Current transformer)
T: CT (Current transformer) is provided, No EVENT input
V: Valve control.
Note 1 : DTB4824 series: no optional function provided and no extra alarm output supported, but user can set
2nd output as alarm mode.
Note 2 : DTB4848 series: only one alarm output when optional function supported, but user can set 2nd output as
2nd alarm output.
Note 3: “Valve control” with feedback selection is only available for DTB9696RRV.
Ordering Information
2
4 Specifications
Input Voltage 100 to 240VAC 50/60Hz
Operation Voltage
Range
85% to 110% of rated voltage
Power Consumption 5VA max.
Memory Protection EEPROM 4K bit (non-volatile memory (number of writes: 100,000)
Display Method
2 line x 4 character 7-segment LED display Process value(PV): Red color, Set point(SV):
Green color
Thermocouple: K, J, T, E, N, R, S, B, L, U, TXK
Sensor Type
3-wire Platinum RTD: Pt100, JPt100
Analog input: 0~5V, 0~10V, 0~ 20 m A, 4~20 m A, 0~50mV
Control Mode PID, ON/OFF, Manual or PID program control (Ramp/Soak control)
Relay output: SPDT (SPST: 1/16 DIN and 1/32 DIN size), Max. load 250VAC, 5A resistive load
Control Output
Voltage pulse output: DC 14V, Max. output current 40mA
Current output: DC 4 ~ 20m A output (Load resistance: Max. 600Ω)
Linear voltage output: 0~5V, 0~10V
Display Accuracy 0 or 1 digit to the right of the decimal point (selectable)
Sampling Rate Analog input: 150 msec/ per scan Thermocouple or Platinum RTD: 400 msec/per scan
RS-485 Communication MODBUS ASCII / RTU communication protocol
Vibration Resistance 10 to 55Hz, 10m/s2 for 10min, each in X, Y and Z directions
Shock Resistance Max. 300m/ s2, 3 times in each 3 axes, 6 directions
Ambient Temperature 0 oC to +50 oC
Storage Temperature -20 oC to +65 oC
Altitude 2000m or less
Relative Humidity 35% to 80% (non-condensing)
5
Input Temperature Sensor
Type
Temperature Sensor Type and Temperature Range
Register ValueLED Display Temperature Range
0~50mV Analog Input 17
4~20mA Analog Input 16
0~20mA Analog Input 15
0V~10V Analog Input 14
0V~5V Analog Input 13
Platinum Resistance (Pt100) 12
Platinum Resistance (JPt100) 11
Thermocouple TXK type 10
Thermocouple U type 9
Thermocouple L type 8
Thermocouple B type 7
Thermocouple S type 6
Thermocouple R type 5
Thermocouple N type 4
-999 ~ 9999
-999 ~ 9999
-999 ~ 9999
-999 ~ 9999
-999 ~ 9999
-200 ~ 600
-20 ~ 400
-200 ~ 800
-200 ~ 500
-200 ~ 850
100 ~ 1800
0 ~ 1700
0 ~ 1700
-200 ~ 1300
o
C
o
C
o
C
o
C
o
C
o
C
o
C
o
C
o
C
3
o
Thermocouple E type 3
Thermocouple T type 2
Thermocouple J type 1
Thermocouple K type 0
0 ~ 600
-200 ~ 400
-100 ~ 1200
-200 ~ 1300
C
o
C
o
C
o
C
Note 1 : An external 250Ω precision resistor should be connected when the current input is selected as the input
temperature sensor type..
Note 2 :
(Operation mode) must be set if user wish to specify decimal point position. Except for the
thermocouple B, S, R type, the decimal point positions of all the other thermocouple type input sensors can
be set.
The default range of analog input is -999 ~ 9999. For example, when a 0~20mA analog input is selected as the
input temperature sensor type, -999 indicates 0mA and 9999 indicates 20mA. If change the input range to 0 ~
2000, then 0 indicates 0mA and 2000 indicates 20mA. One display scale is equal to 0.01mA.
6
Operation
There are three modes of operation: operation, regulation and initial setting. When power is applied, controller
gets into the operation mode. Press the
more than 3 seconds, controller will switch to the initial setting mode. Pressing the
key to switch to regulation mode. If the key is pressed for
key while in the
regulation mode or initial setting mode, forces the controller to return to the operation mode.
PV/SV: Sets the temperature set point and displays the temperature process value. Use
keys to set the
temperature set point.
Setting method: While in any function mode, press the
keys to change settings. Press
key to select the desired function and use the
key to save the changes.
The next flow chart shows how to switch for settings and internal functions:
Regulation ModeOperation Mode
Regulation Mode
Auto-tuning
(Set in PID control and RUN mode)
Press
4 groups PID modes (n=0~3). When n=4,
PID control is auto regulated.
Press
(When PID control is ON and Ti=0,
set th e va l ue o f Pdo F.
Press
PD control offset
setting
Heating hystereisis setting
(Set in ON/OFF control mode)
Press
Cooling hystereisis setting
(Set in ON/OFF control mode)
Press
Pres s key less th an 3 sec
Pres s key
set temperature set point
Press
Press
Press
Press
(This parameter is available only when
ALA1 function enables)
Press
Operation Mode
Use ke y to
Control setting RUN or STOP
Start pattern setting (PID
program control and
Time setting.
Decimal point position selection
(except for B, S, R type, all the
other types can be set)
Upper-limit alarm 1
4
Pres s k ey mo r e th an 3 se c
Press k ey
Initial Setting Mode
Set input type
Press
Set temperature unit
do not display when analog input
Press
Set upper-limit of
temperature range
Press
Press
(See "Pattern and set Editing
selection" for detail)
Press
Set lower-limit of
temperature range
Select control mode
Initial Setting Mode