Delta Electronics AHB1748SHG User Manual

EFB
172 x 50.8 MM SERIES
Bearing Type
*
Ball Bearing Material
*
Impeller : Plastic (UL 94V-0)
s
Frame : Die-Cast Aluminum Lead Wires :
*
UL 1007 AWG #24 O Equivalent
R Red Wire Positive (+) Black Wire Negative (-) Weight : 840g (29.62 oz)
*
DIMENSIONS DRAWING
172.0 0.5
( 6.772 0.020)
162.0 0.3
(6.378 0.012)
o
.5
5
5
LABEL
DELTA ELECTRONICS, INC
o
55.5
8- 4.3 0.3
(8- 0.169 0.012)
P & Q CURVE (AT RATED VOLTAGE)
1.20
30.0
1.00
25.0
0.80
20.0
0.60
15.0
Air Pressure
0.40
10.0
0.20
5.0
0
2
2
(IN H O)
(mm H O)
EFB1712/24/48XG
SH
VH
HH
0
0 2.0 4.0 8.06.0 10.0
0 80.0 160.0 240.0 320.0
Air Flow
H
M
L
10.0 10.0
320.0 10.0
(12.598 0.394)
3
(M /MIN)
(CFM)
+0.8
50.8
-
0.3
+0.031
(2.000 )
-
0.012
7.5
(0.295)
10.0 (0.394)
(0.394)(0.394)
M4
UNIT:
7.5
(0.295)
10.0 (0.394)
mm
(INCH)
MOUNTING PANEL CUTOUT
OUTLET SIDE
INLET SIDE
UNIT:
mm
(INCH)
MODEL
PART NO.
Rated
Voltage
Operating
Voltage
Range
FUNCTION VDC VDC Amp Watt R.P.M
Input
Current
Input
Power
Speed
Maximum
Air Flow
3
.
m /min CFM mmH 2O IN H
Maximum
Air Pressure
Noise
O dB-A
2
EFB1712LG -R00 / -F00 12 8.0 to 14.0 0.79 9.48 EFB1724LG -R00 / -F00 24 12.0 to 28.0 0.39 9.36
2800 5.950 210.12 11.90 0.469 48.0
EFB1748LG -R00 / -F00 48 24.0 to 60.0 0.19 9.12 EFB1712MG -R00 / -F00 12 8.0 to 14.0 0.99 11.88 EFB1724MG -R00 / -F00 24 12.0 to 28.0 0.47 11.28
3050 6.520 230.25 14.50 0.571 50.0
EFB1748MG -R00 / -F00 48 24.0 to 60.0 0.25 12.00 EFB1712HG -R00 / -F00 12 8.0 to 14.0 1.35 16.20 EFB1724HG -R00 / -F00 24 12.0 to 28.0 0.56 13.44
3350 7.130 251.79 17.49 0.689 53.0
EFB1748HG -R00 / -F00 48 24.0 to 60.0 0.31 14.88 EFB1712HHG -R00 / -F00 12 8.0 to 14.0 1.79 21.48 EFB1724HHG -R00 / -F00 24 12.0 to 28.0 0.77 18.48
3700 7.920 279.69 20.30 0.800 55.0
EFB1748HHG -R00 / -F00 48 24.0 to 60.0 0.38 18.24 EFB1724VHG -R00 / -F00 24 12.0 to 28.0 0.97 23.28 EFB1748VHG -R00 / -F00 48 24.0 to 60.0 0.49 23.52
4000 8.560 302.29 23.80 0.937 57.0
EFB1724SHG -R00 / -F00 24 12.0 to 28.0 1.17 28.08 4300 9.203 325.00 27.5 1.083 59.0
* Function type is optional. * The max. air flow and the speed are measured in free air ; max. air pressure is measured at zero air flow. * Noise is measured in anechoic chamber in free air, one meter from intake side. * All readings are typical values at rated voltage. * Specifications are subject to change without notice.
50
http://www.deltaww.com
Loading...