AFB
60 x 60 x 20 MM SERIES
DIMENSIONS DRAWING
(2.362 0.020)
50.0 0.3
(1.969 0.012)
60.0 0.5
3.0 0.3
(0.118 0.012)
20.0 0.5
(0.787 0.020)
3.0 0.3
(0.118 0.012)
60.0 0.5
50.0 0.3
(2.362 0.020)
(1.969 0.012)
(4- 0.177 0.012)
Bearing Type
*
Ball Bearings
Material
*
Impeller & Frame : Plastic (UL 94V-0)
Lead Wires :
*
UL 1007 AWG #24 O Equivalent
Red Wire Positive (+)
Black Wire Negative (-)
Weight : 62g (2.19 oz)
*
Rib Type Only
*
PART NO.
AFB0605LD 5 4.5 to 5.5 0.14 0.70
AFB0612LD 12 7.0 to 13.8 0.07 0.84 3200 0.370 13.06 3.03 0.119 24.0
AFB0624LD 24 14.0 to 27.6 0.03 0.72
AFB0605MD 5 4.5 to 5.5 0.19 0.95
AFB0612MD 12 7.0 to 13.8 0.09 1.08 3600 0.420 14.83 3.83 0.151 26.0
AFB0624MD 24 14.0 to 27.6 0.04 0.96
AFB0605HD / 5 4.5 to 5.5 0.24 1.20
AFB0612HD 12 7.0 to 13.8 0.11 1.32 4000 0.470 16.60 4.80 0.189 28.0
AFB0624HD 24 14.0 to 27.6 0.05 1.20
R
MODEL
Rated
Voltage
FUNCTION VDC VDC Amp Watt R.P.M
/ -F00
-R00 / -F00
-R00 / -F00
/ -F00
-R00 / -F00
-R00 / -F00
-F00
-R00 / -F00
-R00 / -F00
P & Q CURVE (AT RATED VOLTAGE)
0.36
0.30
0.24
0.18
0.12
Air Pressure
0.06
0
2
(IN H O)
Operating
Voltage
Range
AFB0605/12/24XD
9.0
7.5
6.0
4.5
3.0
1.5
0
2
0 6.0 12.0 18.0 24.0
(mm H O)
Air Flow
Input
Current
LABEL
4- 4.5 0.3
VH
HH
Input
Power
10.0
(0.394)
328.0 10.0
(12.913 0.394)
UNIT:
MOUNTING PANEL CUTOUT
OUTLET SIDE
50.0
(1.969)
(4- 0.177)
Air Flow
(1.969)
(
4- 4.5
.2
)
7
2
5
.25
2
50.0
57.2
(2.252)
Maximum
Air Pressure
IN H2
O
H
M
L
50.0
3
(M /MIN)
.75.45 .60.30.150
(CFM)
Speed
Maximum
3
m
/min CFM mmH2
.
AFB0605HHD / -F00 5 4.5 to 5.5 0.33 1.65
AFB0612HHD 12 7.0 to 13.8 0.15 1.80
AFB0624HHD 24 14.0 to 27.6 0.07 1.68
AFB0612VHD 12 7.0 to 13.8 0.18 2.16
AFB0624VHD 24 14.0 to 27.6 0.09 2.16
* Function type is optional.
* The max. air flow and the speed are measured in free air ; max. air pressure is measured at zero air flow.
* Noise is measured in anechoic chamber in free air, one meter from intake side.
* All readings are typical values at rated voltage.
* Specifications are subject to change without notice.
-R00 / -F00
-R00 / -F00
-R00 / -F00
-R00 / -F00
4400 0.520 18.36 5.81 0.229 31.0
4800 0.560 19.78 7.00 0.275 33.0
mm
(INCH)
(1.969)
O
INLET SIDE
57.2
(2.252)
50.0
(1.969)
61.0
( 2.402)
4- 4.5
(4- 0.177)
UNIT:
Noise
dB-A
mm
(INCH)
12
http://www.deltaww.com
Bearing Type
*
Ball Bearings
Material
*
Impeller & Frame : Plastic (UL 94V-0)
*
Lead Wires :
*
UL 1007 AWG #24 OR Equivalent
Red Wire Positive (+)
Black Wire Negative (-)
Weight : 56g (1.98 oz)
*
AFB
60 x 60 x 20 MM SERIES
DIMENSIONS DRAWING
P & Q CURVE (AT RATED VOLTAGE)
LABEL
UNIT:
MOUNTING PANEL CUTOUT
OUTLET SIDE
INLET SIDE
mm
(INCH)
MODEL
PART NO.
AFB0612VHD -A -R00 / -F00 12 7.0 to 13.8 0.19 2.28 5400 0.823 29.06 8.72 0.343 41.0
AFB0612SHD -A -R00 / -F00 12 7.0 to 13.8 0.28 3.36 6000 0.911 32.17 10.41 0.410 43.0
AFB0612EHD -A -R00 / -F00 12 7.0 to 13.8 0.31 3.72 6600 0.997 35.21 12.29 0.484 45.0
* Function type is optional.
The max. air flow and the speed are measured in free air ; max. air pressure is measured at zero air flow.
*
Noise is measured in anechoic chamber in free air, one meter from intake side.
*
All readings are typical values at rated voltage.
*
Specifications are subject to change without notice.
*
REV.
FUNCTION
Rated
Voltage
VDC VDC
Operating
Voltage
Range
Input
Current
Amp
Input
Power
Watt
Speed
R.P.M
.
Maximum
Air Flow
CFM
Maximum
Air Pressure
mmH
O
2
IN
H
O
2
Noise
dB-A
UNIT:
mm
(INCH)
13
http://www.deltaww.com