Delta Breez SIG80-110, SIG80-110LED Installation Guide

VENTILATION FAN / LED LIGHT /
LED NIGHT LIGHT
MODELS SIG80-110 / SIG80-110D / SIG80-110H / SIG80-110MH /
TABLE OF CONTENTS
Package Contents 2
General Safety Information 3
Preparation 4
Wiring Diagrams 5
Assembly Instructions - New Construction 6
Assembly Instructions - Existing Construction 7
Grille Installation 11
READ AND SAVE THESE INSTRUCTIONS
Address: 46101 Fremont Boulevard, Fremont, CA 94538 US Toll Free Number: 1-888-979-9889 – Technical Support 1-877-685-4384 – Customer Sales Support www.deltabreez.com
Operation 12
Care and Maintenance 13
Troubleshooting 14
Dimensions 15
15
Warranty 16
PACKAGE CONTENTS
PART DESCRIPTION QTY
1
1
2
3
4
Fan Body 1
Suspension bracket 4
6" to 4" adapter 1
Grille 1
HARDWARE CONTENTS
(Images are to scale)
2
A
Long Wood Screw ( 4 x 25mm)
3
B
Short screw (#8-32x1/4”)
X 8
X 4
4
SIG80-110 SIG80-110D SIG80-110H
SIG80-110MH
SIG80-110LED SIG80-110DLED SIG80-110HLED
SIG80-110MHLED
2
GENERAL SAFETY INFORMATION
Turning angle too large Duct shrink
ydob eht raen woblEswoble ynam ooT
Body
Minimum 18 in.
READ AND SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION
1. Make sure that the electric service supply voltage is AC 120V, 60Hz.
2. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupational Safety and Health Act (OSH Act).
3. Always disconnect the power source before working on or near the ventilating fan, motor or junction box.
4. Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals or other objects.
5. Do not kink the power cord.
6. shown in Fig.A.
7. Provide suction parts with proper ventilation.
8. This unit is UL Listed for use over a bathtub or shower when installed in a GFCI protected branch circuit.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
2. Before servicing or cleaning the unit, switch the power off at the service panel and lock the service disconnecting means to prevent the power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by
4.
7. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit lnterrupter) – protected branch circuit.
8. Do not use this unit with any other solid-state control device. Solid-state controls may cause harmonic distortion, which can cause a motor humming noise.
9. NEVER place a switch where it can be reached from a tub or shower.
10. Not to be installed in a ceiling thermally insulated to a value greater than R40. (This is required for installation in Canada only).
Turning angle too large Duct shrink
ydob eht raen woblEswoble ynam ooT
Body
Minimum 18 in.
Fig. A
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. Not for use in cooking areas. (Fig.B)
3. This product must properly connect to the grounding
conductor of the supply circuit.
4. To reduce the risk of injury to persons, install the fan at
burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating Refrigeration and Air Conditioning Engineers (ASHRAE) and local code authorities.
5. When cutting or drilling into the wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted ventilating fans must always be vented to the outdoors.
Cooking area
Do not install above or
inside this area
4
5
4
Cooking
Equipment
°
floor
Fig. B
3
PREPARATION
Tools Required for Assembly (not included): Hammer, Flathead Screwdriver, Wire Nuts, Nails, Duct Tape, Phillips Head Screwdriver, Utility Knife
Helpful Tools (not included): Electric Drill, Drill Bits
WARNING: Turn off electricity at breaker box before beginning installation.
Carefully remove unit from carton. Check area above installation location to be sure that
wiring can run to the planned location and that duct
proper ventilation. Inspect duct work and wiring before proceeding with
installation. Before installation, provide inspection and future
maintenance acc ess at a location that will not interfere with installation work.
You may need the help of a second person to install this fan: one person on the attic side and one on the room side.
Note: Installations may vary depending on how the previous bath fan was installed. Supplies necessary for the installation of your bath fan are not all included. Howev er, most are available at your local home improvement or hardware store.
Proper insulation around the fan to minimize building heat loss and gain. 6” circular duct is recommended for installation. The ducting from this fan to the outside of building has a strong effect on the
shortest, straightest duct routing possible for best performance,and avoid installing the fan with smaller ducts than recommended. Insulation around the ducts can reduceenergy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated
Roof cap (with built-in
Short piece of flexible duct helps alignment and absorbs sound
Fan housing
Seal gap around housing
2~3 ft straight run before elbow
Caulk termination to duct
damper)
or
Wall cap
Wall cap (with built-in
(with built-in damper)
damper)
where the shortest possible duct run and minimum number of elbows will be needed.
Use a roof cap or wall cap that has a built-in damper
to reduce backdrafts.
External timer/dimmer switch can be used please contact Delta Breez customer service and consult with a licensed electrician for compatibility .
For humidity sensing models only (SIG80-110H, SIG80-110MH, SIG80-110HLED, SIG80-110MHLED)
or within 5 feet of the shower head.
Locate unit away from heating or cooling sources
which can affect humidity levels.
Do not locate near window. Unit may respond to the outdoor humidity level.
Unit must be installed in ceiling to properly sense moisture.
proper sensing.
4
)deriuqer tiucric detcetorp-ICFG( evoba tinu etacoL
WIRING DIAGRAM
Models: SIG80-110, SIG80-110MH
JUNCTION BOX
BLACK
WHITE
GREEN
BLACK
ON/OFF SWITCH
(purchase separately)
POWER
SWITCH
Model: SIG80-110LED
JUNCTION BOX
ON/OFF SWITCH
(purchase separately)
LIGHT
NIGHT-
SWITCH
LIGHT
SWITCH
Models: SIG80-110H, SIG80-110D
JUNCTION BOX
ON/OFF SWITCH
(purchase separately)
POWER SWITCH
SWITCH BOX
120 VAC
LINE IN
RED
SWITCH BOX
120 VAC
BLUE
(bare)
SWITCH BOX
RED
WHITE
YELLOW
WHITE
BLACK
WHITE
GREEN
YELLOW
LINE IN
BLACK
WHITE
BLUE
WHITE
GREEN
SWITCH BOX
OFF
ON
POWER SWITCH
WHITE
GROUND
(bare)
WIRING
PLATE
SWITCH BOX
OFF
ON
LIGHT SWITCH
OFF
ON
NIGHT-LIGHT SWITCH
OFF
ON
POWER SWITCH
BLACK WHITE
GROUND
(bare)
WIRING
PLATE
SWITCH BOX
OFF
ON
POWER SWITCH
HI
MODE SWITCH
BLACK WHITEGROUND
GRD
GRD
GRD
Models: SIG80-110HLED, SIG80-110DLED
JUNCTION BOX
L
N
RED
WHITE
YELLOW
WHITE
BLACK
WHITE
BLUE
WHITE
GREEN
RED YELLOW
ON/OFF SWITCH
(purchase separate ly)
L
BLUE
(bare)
SWITCH BOX
N
MODE
SWITCH
POWER SWITCH
RED
WHITE
YELLOW
WHITE
BLACK
WHITE
BLUE
WHITE
GREEN
SWITCH BOX
120 VAC
RED YELLOW
BLUE
LINE IN
LIGHT
L
N
L
N
NIGHT-
SWITCH
LIGHT
SWITCH
Model: SIG80-110MHLED
JUNCTION BOX
L
N
ON/OFF SWITCH
(purchase separately)
L
N
MODE
NIGHT­LIGHT
SWITCH
SWITCH
POWER SWITCH
120 VAC
LINE IN
SWITCH BOX
OFF
ON
LIGHT SWITCH
OFF
ON
NIGHT-LIGHT SWITCH
OFF
ON
POWER SWITCH
HI
MODE SWITCH
BLACK WHITEGROUND
WIRING
PLATE
SWITCH BOX
OFF
ON
NIGHT-LIGHT SWITCH
OFF
ON
POWER SWITCH
HI
MODE SWITCH
BLACK WHITE
GROUND
(bare)
WIRING PLATE
L
N
L
N
L
N
L
N
GRD
L
N
L
N
L
N
GRD
MODE
SWITCH
POWER SWITCH
120 VAC
LINE IN
WIRING
PLATE
5
ASSEMBLY INSTRUCTIONS
NEW CONSTRUCTION – ATTACHING TO THE JOIST
BEFORE INSTALLATION
Turn off power source. Review all safety precautions.
1. If spacing between joists is 12 in. apart, use four long wood screws (provided) to attach the fan body
1
to ceiling joists, NO NEED FOR SUSPENSION
BRACKETS.
Hardware
A
Long wood screw
2. For joist spacing 16 in.- 24 in., insert suspension bracket into the bracket cover on the duct connector side and the back of the fan body . .
2
1
Install the suspension brackets to the joists with long wood screw, and secure the suspension brackets to the fan body by using the short
1
screws (provided).
Hardware
A
Long wood screw
1
Joist
1
A
2
Fan Body
1
2
Suspension Bracket
Joist
B
Short screw
16"(406mm)
19.2"(487mm) 24"(609mm)
6
ASSEMBLY INSTRUCTIONS
3. Remove the fan junction box cover
. Using wire nuts (not supplied), connect house wires to fan wires as shown in the wiring diagram on page 5 .
14AWG is the smallest conductor that shall be used for branch-circuit wiring. Reattach fan junction box
cover .
4. Connect a 6 in. circular duct (not supplied) and vent to the outside. Secure it with duct tape (not supplied) or clamp (not supplied) to make the connection secure and air tight.
5. Punch out Mask from packaging. Insert mask and
3
b
c
a
4
a
Joist
Joist
5
Mask protects unit during construction.
Remove before installing Grille.
EXISTING CONSTRUCTION BEFORE INSTALLATION
Turn off power source. Review all safety precautions.
1. Remove existing fan.
1
7
ASSEMBLY INSTRUCTIONS
2. Measure the opening to ensure it is large enough
to accommodate the new fan body (10 1/4 in. x 10 1/4 in.).
3. If this fan is not replacing an old fan, be sure to cut
a 10 1/4 in. x 10 1/4 in. opening for the fan body
1
.
Install from below, no need for suspension brackets (no attic access)
4. Remove fan unit by removing 3 screws.
2
3
in.
9.4"
1/4
10
10
1/4
9.4"
in.
4
5. Remove duct connector by removing duct screw.
6. A piece of wood (not supplied) is screwed in
from below through the ceiling board. Suggested size is 1 in. x 3 in. x 14 in. Position the screws far enough away from the edge of the ceiling board that it does not crumble and give way. Put screws in both ends of wood beyond the 10 1/4 in. hole. Keep screws in range of grille.
5
Duct screw
6
Wood support screwed in from underneath. Screw is far enough away from the edge of sheetrock to prevent crumblimg.
Wood support
8
ASSEMBLY INSTRUCTIONS
7. Remove the fan junction box cover . Using
wire nuts (not supplied), connect house wires to fan wires  as shown in the wiring diagram on page 5. 14AWG is the smallest conductor that shall
be used for branch-circuit wiring. Reattach fan junction
box cover .
8. Insert housing can into the ceiling cut out. Secure
the housing can from below by using 2 long wood
joist.
2
ac
b
3
Hardware
A
Long wood screw
9. Attach the duct connector from the housing can
inside, and secure using the duct screw.
10. Insert fan unit and secure by 3 screws.
4
Duct screw(M4X12)
4
1
Pull existing ductwork into Housing
2
Insert tab into slot
3
in Housing
5
9
ASSEMBLY INSTRUCTIONS
Install from above with suspension brackets (attic accessible)
*ONLY IF UNABLE TO ATTACH DIRECTLY TO JOIST(S)
1. For joist spacing 16 in.- 24 in., insert suspension
bracket into the bracket cover on the duct connector side and the back of the fan body
2
1
Install the suspension brackets to the joists with long wood screw, and secure the suspension brackets to the fan body by using the short
1
screws (provided).
Hardware
A
Long wood screw
B
Short screw
1
Fan Body
1
2
Suspension Bracket
16"(406mm)
19.2"(487mm) 24"(609mm)
2
2. Remove the fan junction box cover
. Using wire nuts (not supplied), connect house wires to fan wires .5 egap no margaid gniriw eht ni nwohs sa
14AWG is the smallest conductor that shall be used for branch-circuit wiring.
Reattach fan junction box
cover .
3. Connect a 6 in. circular duct
(not supplied) and vent to the outside. Secure it with duct tape (not supplied) or clamp (not supplied) to make the connection secure and air tight.
2
b
c
a
3
a
Joist
Joist
10
GRILLE INSTALLATION
Celling
Grille
LED light connector
Spring
Slots
r
connector
Ce
Model: SIG80-110MHLED
Insert the LED light connector and the motion sensor connector into the fan body.
Celling
LED light connector
Grille
Spring
Motion senso
Models: SIG80-110LED, SIG80-110DLED, SIG80-110HLED
Insert the LED light connector into the fan body.
Models: SIG80-110, SIG80-110D, SIG80-110H, SIG80-110MH
Insert the motion sensor connector into the fan body (SIG80-110MH only).
Attach grille by pinching mounting springs
4
a
and
insert into the narrow rectangular slots in fan body.
lling
LED light connector
Slots
Spring
Grille
a
4
11
OPERATION
80
60
50
30
90
80
70
60
Full speed air volume
LED indicator
80
60
50
30
45
30
15
5
80
60
50
30
90
80
70
60
80
60
50
30
90
80
70
60
preset control
Low speed air volume preset control (SIG80-110D, SIG80-110DLED, SIG80-110H, SIG80-110HLED, SIG80-110MH, SIG80-110MHLED)
Delay time control (SIG80-110D & SIG80-110DLED) or Humidity preset control (SIG80-110H, SIG80-110HLED, SIG80-110MH, SIG80-110MHLED).
LOW SPEED
SIG80-110D / SIG80-110DLED
CFM
TIME(min)
0
60
0.5
LOW SPEED
CFM
0
MOTION
MOTION
CONTROL
CONTROL
FAN
FAN
LIGHT
LIGHT
FAN/LIGHT
FAN/LIGHT
Motion sensor preset control (SIG80-110MHLED).
SIG80-110MHLED
MOTION
CONTROL
FAN
LIGHT
FAN/LIGHT
SIG80-110H / SIG80-110HLED SIG80-110MH / SIG80-110MHLED
%RH
%RH
50
50
%RH
LOW SPEED
LOW SPEED
CFM
CFM
50
110
80
0
0
Single Speed Models: SIG80-110, SIG80-110LED
Turn the POWER switch on to operate at user­adjustable full speed airflow - the LED indicator will be green.
Humidity Models: SIG80-110H, SIG80-110HLED
Humidity control mode: Turn the POWER switch on to
operate at humidity control mode - the LED indicator will be blue. When the ambient humidity is higher than the user-adjustable set-point, the fan will run at full speed, and the LED indicator is blue. When the ambient humidity is lower than the setpoint, the fan will continue to run at the full speed until a 10-minute time delay has elapsed, and then will automatically change to the user-adjustable low speed airflow.
Full speed mode: Turn the MODE switch on to
operate at user-adjustable full speed airflow ­the LED indicator will be amber.
Humidity tolerance is about ±10%. The humidity
switch may need to be adjusted regionally. Long­time operation will influence the detecting precision
as dust accumlates. Factory setting: High speed airflow 110CFM, low speed airflow 30CFM, humidity 60%RH.
Dual Speed Models: SIG80-110D, SIG80-
110DLED
• Low speed control mode: Turn the POWER switch
on (MODE switch is off) to operate at the user-
green.
• Full speed control mode: Turn the POWER switch
& MODE switch on to operate at user-adjustable full speed mode - the LED indicator will be ambe When the user turns the MODE switch o
ff, the fan
r.
will continue to run at the full speed until the user­adjustable time delay has elapsed, and then will automatically change to the user-adjustable low
Factory setting: High speed airflow 110CFM, low speed airflow 30CFM, time delay 5 minutes.
Motion / Humidity with LED light Model:
SIG80-110MHLED
Motion control mode: Turn the POWER switch on to operate motion control mode.
If motion control switch to FAN position, when motion is detected, the fan will run at user-adjustable full speed airflow and the LED indicator will be amber. When motion is not detected, the fan will continue to run at the full speed until a 20-minute time delay has elapsed, and then will auto-matically change to the humidity control mode. The LED indicator will be blue. LED main light will be controlled by MODE switch ON/OFF.
If motion control switch to LIGHT position, when motion is detected, the LED lighting will be on. When motion is not detected, the LED lighting will continue to on until a 30-sec­ond time delay has elapsed,and then will automatically off. The fan will operate at humidity control mode. Turn the MODE switch on to operate at user-adjustable full speed airflow - the LED indicator will be amber.
If motion control switch to FAN/LIGHT position, when motion is detected, the LED lighting will be on and the fan will run at user-adjustable full speed airflow and the LED indicator will be amber. When motion is not detect­ed, the light will continue to on until a 30-second time delay has elapsed and then will auto-matically off. The fan will continue to run at the full speed until a 20-minute time delay has elapsed, and then will automatically change to the humidity control mode. The LED indicator will be blue. The MODE switch is no function.
Factory setting: High speed airflow
110CFM, motion control
switch to FAN, low speed airflow 30CFM, humidity 60%RH.
Motion / Humidity Model: SIG80-110MH
• Motion control mode: Turn the POWER switch on to operate at user-adjustable motion control mode. When motion is detected, the fan will run at user-
will be amber. When motion is not detected, the fan will continue to run at the full speed until a 20-minute time delay has elapsed, and then will automatically change to the humidity control mode. The LED indicator will be blue.
Factory setting: High speed airflow 110CFM, low speed airflow 30CFM, humidity 60%RH.
Motion sensor detectible range: The distance that motion can
10 feet
be detected is limited to 10 feet (3m). The field of
(3m)
Sensor
view of the sensor is 90°. (Room temperature is 25°C)
12
90°
CARE AND MAINTENANCE
See safety information before proceeding. Routine maintenance should be done at least once a year.
• Never use solvents, thinner or harsh chemicals when cleaning the fan.
• Do not allow water to enter the motor.
• Do not immerse metal parts in water.
• Do not immerse resin parts in water over 140º Fahrenheit.
Turn off power source. Review all safety precautions.
1
1. To remove grille , squeeze springs and pull down.
2. Clean the grille in a sink and dry with a cloth.
3. Remove dust and dirt from the fan body with a vacuum
4
4
1
cleaner.
4. Dampen cloth with dust detergent and wipe the fan body
1
. Then wipe dry with a clean cloth.
4
2
4
3
Vacuum
1
cleaner
4
5. Replace grille back onto fan body .
14
4
6. Turn on power source to operate fan again.
1
5
4
13
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
The fan is not turning on 1. Power off
2. Faulty switch
3. Faulty wire connection
The fan seems louder than it should
The fan is not clearing the room
1. CFM too great
2. Damper not working properly or damaged
3. Bend in duct too close to fan discharge
4. Fan discharge
duct
5. Fan body not securely attached
1. airfow within room
1. Make sure power supply is on.
2. Test or replace switch.
3. Check wire in switch box.
1. Be sure the CFM rating on the fan matches the size of your room.
2. Check damper to ensure it is opening and closing properly. If the damper has become damaged, please call Customer Service.
3. Be sure you do not have any sharp bends in duct closer than 18 in. to the fan discharge.
4. Use recommended size ducting to reduce fan noise.
5. Be sure the fan is securely attached to your ceiling joists.
1. Be sure a door or window is slightly ajar or opened
The light is not turning ON
The fan keeps running even though the house humidity level is lower than set humidity level
2.
1. Power off
2. Faulty switch
3. Faulty wire connection
1. Our sensor tolerance is +/-10% RH
2. Outdoor humidity is back drafting to the fan
2. Be sure the CFM rating on the fan matches the requirements for your room size.
1. Make sure power supply is on.
2. Test or replace switch.
3. Check wire in switch box.
1. Continue to let the fan run since it is good to keep venting the house and the electric bill is minimal (approximately less than $10 per year).
2. Turn the fan off when not in use.
14
DIMENSIONS
Models: SIG80-110 / SIG80-110D
Models: SIG80-110LED / SIG80-110DLED
SIG80-110H / SIG80-110MH
(314.0)
(295.8)
12 3/8 (314.0)
9 21/32
(245.4)
3 3/4 (94.4)
6
(150)
11 21/32
12 23/64
13/16 (20.0)
PRODUCT SPECIFICATIONS
7 7/8
(200)
SIG80-110HLED / SIG80-110MHLED
12 3/8 (314.0)
9 21/32
(245.4)
3 3/4 (94.4)
(295.8)
6
11 21/32
(150)
(314.0)
12 23/64
13/16
(20.0)
7 7/8 (200)
Unit: Inches(mm)
Model No.
SIG80-110 120 60 110
SIG80-110D 120 60 110
SIG80-110H 120 60 110
SIG80-110MH 120 60 110
SIG80-110LED 120 60 110
SIG80-110DLED 120 60 110
SIG80-110HLED 120 60 110
SIG80-110MHLED 120 60 110
Voltage
(V)
Frequency
(Hz)
SPECIFICATIONS
Air Flow
@ 0.1”SP
(CFM)
Power
@ 0.1”SP
(W)
8.2
8.2
8.2
8.2
9.7
9.7
9.7
9.7
Max.
Current
(amps)
0.38 10
0.38 10
0.38 10
0.38 10
0.48 10
0.48 10
0.48 10
0.48 10
Weight
(lb.)
Note LED light spec
Single Speed
Dual
Speed
Humidity
Sensor
Motion /
Humidity
Sensor
Single Speed
Dual
Speed
Humidity
Sensor
Motion /
Humidity
Sensor
13 Watts, 850
Lumens, 3000K
13 Watts, 850
Lumens, 3000K
13 Watts, 850
Lumens, 3000K
13 Watts, 850
Lumens, 3000K
15
WARRANTY
DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY
Delta Electronics Inc. (“Delta Electronics”) warrants to the original consumer purchaser in the USA that the Breez ventilation fan products will be free from defects in material or workmanship. This warranty is limited to three (3) years from the original date of purchase.
Limitations and Exclusions
1. During the warranty period, a replacement for any defective product will be supplied free of charge for installation by the consumer. The warranty provided herein does not cover charges for labor or other costs incurred in the troubleshooting, repair, removal, and installation service.
2. All returns of defective parts or products must include the product model number, and must be made through an authorized Delta Electronics distributor. Authorized returns must be shipped prepaid. Repaired or replacement products will be shipped by Delta Electronics F.O.B. shipping point.
3. Delta Electronics shall not be liable for any indirect, incidental, consequential, punitive, or special damages arising out of or in connection with products use or performance, regardless of the form of action whether in contract, tort (including negligence), strict product liability or otherwise.
4.
5. The warranty does not cover if user does not comply with manufacturer’s installation manual.
6. To qualify for warranty service, you must notify Delta Electronics at the address or telephone number below.
7. Delta Electronics shall have no liability to the original owner-user with respect to any defect caused by abuse, misuse, neglect, improper transportation or storage, improper testing, improper installation, improper operation,
accident of products or parts thereof, or unusual deterioration or degradation of products or parts thereof due to
Address: 46101 Fremont Boulevard, Fremont, CA 94538 US Toll Free Number: 1-888-979-9889 – Technical Support 1-877-685-4384 – Customer Sales Support www.deltabreez.com
16