Back Panel
RS-232
5 PIN terminal/Wire gauge: 12-24 AWG/Torque: 4.5 lb.-inch
Dimension
Front panel (unit: mm [inch]) Right side diagram (unit: mm [inch])
Vertical view (unit: mm) Mounting dimension (unit: mm [inch])
85
[3.35]
135~136.5[5. 31~5.37]
Thickness Ran ge 0.5~9mm
Installation
Please insert TP02 series to the opening hole of panel and tighten the screws. However, if a firm mounting
TP02 series to the panel is needed, please use the mounting fixed support accessory which is packed together
with TP02 series, then insert the fixed support in the back and tighten the screws.
If the fixed support is not installed well, Delta will not guarantee the waterproof function. The screw torque
should be 4-5(kg-cm). DO NOT exceed this specification when tightening the screws; otherwise TP02 series
may be damaged. Please leave sufficient space (more than 50mm) around the unit for heat dissipation.
Notes: The flat surface should be a UL Type 4 "Indoor Use Only" enclosure or equivalent (IP65/NEMA4). Please refer to
the figures below.
Specifications TP02G-AS1
Storage temperature for
hardware
Vibration
Shock
-20 ~ 60°C
5Hz f
≦
<
9Hz = Continuous: 1.75mm / Occasional: 3.5mm
9Hz f 150Hz = Continuous: 0.5g / Occasional: 1.0g
≦ ≦
15g peak, 11ms duration, half-sine, three shocks in each direction per axis,
on 3 mutually perpendicular axes (total of 18 shocks)
Radiated emission CISPR11, Class A
Electrostatic discharge immunity EN61000-4-2
Radiated immunity EN61000-4-3
Electrical fast transient EN61000-4-4
Weight/dimensions 0.24kg; 147 × 97 × 35.5mm (Width(W) × Height(H) × Deep(D))
Cooling method Natural air cooling
Password Function
1. If the user forgot the password, the password can be cleared by using the following code: 8888. This
universal code will clear the password and all TP02 series internal programs. The TP02 series will be reset to
the factory settings by using this code also. Please pay close attention when using it.
2. The password can be the alphabet from A to Z or the number from 0 to 9. But it must use the function keys F0
~ F9 to input the password characters. Please refer to the following table.
F0: scrolls in a loop as follows 0→A→B→C→D→E→F→0.
F1: scrolls in a loop as follows 1→G→H→I→J→K→1.
F2: scrolls in a loop as follows 2→L→M→N→O→P→2.
F3: scrolls in a loop as follows 3→Q→R→S→T→U→ V→3.
F4: scrolls in a loop as follows 4→W→X→Y→Z→4.
F5: It just can be used to be constant 5.
F6: It just can be used to be constant 6.
F7: It just can be used to be constant 7.
F8: It just can be used to be constant 8.
F9: It just can be used to be constant 9.
Hardware Operation
When the user wants to startup TP02 series, a 24V DC power is needed. After applying 24V DC power to TP02
series, it will enter into the startup display and then enter the user-designed program. Pressing Esc key and
holding on for 5 seconds can return to system menu. There are five selections in the system menu and are
described below.
Selections Explanation
Download
program
Upload program
Copy program
Use the connection cable (DVPACAB530) to connect the TP02 serial communication port RS-232 to a
PC. Then use the TPEditor software to download an application program to TP02.
Use the connection cable (DVPACAB530) to connect the TP02 serial communication port RS-232 to a
PC. Then use the TPEditor software to upload an application program from TP02.
Transfer a program between two TP02 units.
1: transmit programs; 2: receive programs.
When transmit programs and data between t wo TP02 units. Set one TP02 to “Receive Program”
mode and the other TP02 to “Transmit Program” mode. Please use twisted pair wires to connect the
two units via the RS-485 po rts.
注意事項
請在使用之前,詳細閱讀本使用說明書。
實施配線,務必關閉電源。
本機顯示操作面板防水,但對油污或具腐蝕性之液體不具防護作用,避免以尖銳之物品刮傷面板使用時請注
意。
本機輸入電源為直流
再次確認電源配線。
輸入電源切斷後,一分鐘之內,請勿觸摸內部電路。請勿在上電時觸摸任何端子。
本體上之接地端子
利用原廠包裝附件之固定架,鎖緊面板固定螺絲時,請勿太緊以免造成機殼損壞。
產品簡介
產品外觀及各部介紹
面板功能說明
面板元件
警示指示燈(紅燈)
RS-232
指示燈(黃燈) 傳送程式及使用
RS-485
指示燈(綠燈) 使用
退出/取消鍵
命令操作鍵
輸入鍵
數值鍵及功能鍵
24V
,不可連接於
務必正確的接地,可提高產品抗雜訊能力。
LCM
顯示區
退出 取消鍵
/
狀態一:當啟動電源時,指示燈慢慢開始閃爍三次。
狀態二:當異常狀態發生,指示燈會重覆持續亮一秒並發出警報聲。
RS-485
輸入值錯誤時可按此鍵,刪除文字敘述等。
UP/Pg Up
Pg Dn/DOWN
Left
:此鍵為左方向鍵,可作為選擇數值位置操作。
Right
:此鍵為右方向鍵。可作為選擇數值位置操作。
當輸入值確認正確無誤時,即可按下此鍵。
F0/0
:可作為0的常數輸入鍵,也可由使用者定義其個別功能
F1/1
:可作為1的常數輸入鍵,也可由使用者定義其個別功能
F2/2
:可作為2的常數輸入鍵,也可由使用者定義其個別功能
F3/3
:可作為3的常數輸入鍵,也可由使用者定義其個別功能
F4/4
:可作為4的常數輸入鍵,也可由使用者定義其個別功能
F5/5
:可作為5的常數輸入鍵,也可由使用者定義其個別功能
F6/6
:可作為6的常數輸入鍵,也可由使用者定義其個別功能
F7/7
:可作為7的常數輸入鍵,也可由使用者定義其個別功能
F8/8
:可作為8的常數輸入鍵,也可由使用者定義其個別功能
F9/9
:可作為9的常數輸入鍵,也可由使用者定義其個別功能
RS-485
通訊口信號端,否則可能造成嚴重的損壞,因此請在上電之前
警示指示燈
RS -232
RS -485
輸入鍵
說明
RS-232
通訊時持續閃爍。
通訊時持續閃爍。
:此鍵為向上方向鍵,可作為數值遞增輸入或換至上頁等操作。
:此鍵為向下方向鍵,可作為數值遞減輸入或換至下頁等操作。
F0。
F1。
F2。
F3。
F4。
F5。
F6。
F7。
F8。
F9。
繁體中文
Warning
Please read this instruction carefully before use.
Switch off the power before wiring.
The display panel of TP02 series is waterproof. But please prevent grease, corrosive liquids and sharp objects from
contacting the TP02 series.
The TP02 series require 24V DC input power. DO NOT connect input AC power supply to any of the RS-485
communication port; otherwise serious damage may occur. Check all the wiring again before switching on the
power.
DO NOT touch any terminal when the power is switched on. DO NOT touch any internal circuit in 1 minute after
the power is switched off.
Make sure the groud terminal is correctly grounded in order to prevent electromagnetic interference.
Please use the fixed support accessory which is packed together with the product provided by Delta. DO NOT
tighten the screws out of the normal torque specifications; otherwise serious damage may occur.
ENGLISH
Introduction
Product Outline
Alarm LED Indica tor
Displ aying Area
Escape / Exi t Key
Panel Function Explanation
Panel component
Alarm LED
indicator (RED)
RS-232 LED
indicator (yellow)
RS-485 LED
indicator (green)
Displaying area Liquid Crystal Module display area. I t is used to display current program status.
Escape/Exit key It is used to cancel an incorrect input, or to exit a programming step.
Enter key It is used to input a value or accept a programming command.
Arrow keys
Function keys
Status 1: When power is on, LED will blink slowly for three times.
Status 2: When there is an abnormal situation, LED will blink quickly along with an alarm sound.
LED will blink when transmits program and com municates via RS-232.
LED will blink when com municates via RS-485.
UP/Pg Up: It is used to increase the value or move up one page.
Pg Dn/DOWN: It is used to decrease the value or move down one page.
Left: This key is left direction key and it ca n be used to select the position of the value.
Right: This key is right direction key and it can be used to select the position of the value.
F0/0: It is used as a co nstant 0, or the user can def ine it as function F0.
F1/1: It is used as a co nstant 1, or the user can def ine it as function F1.
F2/2: It is used as a co nstant 2, or the user can def ine it as function F2.
F3/3: It is used as a constant 3, or the user can define it as function F3.
F4/4: It is used as a co nstant 4, or the user can def ine it as function F4.
F5/5: It is used as a co nstant 5, or the user can def ine it as function F5.
F6/6: It is used as a constant 6, or the user can define it as function F6.
F7/7: It is used as a co nstant 7, or the user can def ine it as function F7.
F8/8: It is used as a co nstant 8, or the user can def ine it as function F8.
F9/9: It is used as a co nstant 9, or the user can def ine it as function F9.
Explanation
Functio n Keys
Arrow Ke ys
Enter Key
Specifications
Function Specifications
Item TP02G-AS1
Screen type STN-LCD
Display color Monochromatic
Backlight
Resolution 160 x 32 dots
Display range (W) x (H) = 72 x 22 (unit: mm)
Contrast adjustment 15 levels of adjustment
Display
screen
Language/font
Font size ASCII: 5 × 8, 8 × 8, 8 × 12, 8 × 16
Alarm LED indicator
(RED)
RS-232 LED
indicator (yellow)
RS-485 LED
Indicator (green)
Program memory 256KB flash memory
RAM of system 32K Byte
Serial
communication port
RS-232 (COM1)
Extension
External
communication port
interface
RS-485 (COM2)
Extension interface 1. Update firmware version
5 PIN removal
terminal
Electrical Specifications
Specifications TP02G-AS1
Communication interface COM1: RS-232 COM2: RS-485
Waterproof class of front panel IP65/NEMA4
Operating temperature for
hardware
The back-light automatic turn off time is 1 ~ 99 minutes (0 = DO NOT turn off)
(The back-light life is about 50 thousand hours at 25°C)
ASCII: Alphanumeric (including European characters)
Taiwan: (Big 5 codes) Traditional Chinese Fonts
China: (GB2324-80 codes) Simplified Chinese Fonts
1. Power on indication (blink for three times)
2. Communication error alarm
3. Special indication by user programming
5×8 dots, 25 characters×8 rows
8×8 dots, 16 characters×8 rows
8×12 dots, 16 characters×5 rows
8×16 dots, 16 characters×4 rows
It will blink when transmitting program and communicating by using RS-232.
It will blink when communicating by using RS-485.
Unsynchronized transmission method: RS-232
Data length: 7 or 8 bits, Stop bits: 1 or 2 bits
Parity: none/odd/even, Transmission speed: 4,800 bps ~115,200 bps
RS-232: 9 PIN D-SUB male
Unsynchronized transmission method: RS-485
Data length: 7 or 8 bits, Stop bits: 1 or 2 bits
Parity: None/Odd/Even, Transmission speed: 4,800 bps ~115,200 bps
RS-485: 5 PIN removal terminal
2. The slot for program copy card
Include 24V DC input and RS-485 communication input
0 ~ 50°C; 20 ~ 90%RH (non-condensing)
Selections Explanation
TP02 settings
PLC connection
Execution
There are 8 items that used to modify TP02 system settings:
1. Communication protocol: Setting the address of TP02, the control port of PLC, and the
communication string for either RS- 232 or RS-485.
2. Contrast: Adjust the contrast of LCM display screen.
3. Back-light: adjust the autom atic turn off time of LCM. Setting range is 00 ~ 99 minutes. If set to 00,
the LCM Back-light will not turn off.
4. Buzzer: Used to set the buzzer sound, normal m ode or quiet mode.
5. Language setting: Used to set the displayed language. English, Traditional Ch inese, Simplified
Chinese or user defined language.
6. Password setting: Used to set, enable, and disable the password function. If the password f unction
is enabled, it will require the user to input a password before entering any system menu. The
factory password is 1234.
7. Startup display: Used to select the TP02 startup display. User can select “user defined” to use the
file that designed by TPEditor and download to TP02.
8. Comm. indicator: The user can determine if the RS-23 2 and RS-485 LEDs will blink or not during
communication.
There are two methods to connect to PLC:
1. U sing TP02 serial communication port (COM1) RS-232: set 8-pin DIP switch to RS-485 mode and
connect the cable (DVPACAB215 or DVPACAB230) to program communication I/O RS -232C of
PLC.
2. U sing extension communication port (COM2) RS-485: set 8-pin DIP switch to RS-485 mode and
connect 5-pin removal terminal of extension communication port to RS-485 of PLC with twisted
pair.
Execute the internal program that download from TPEditor or transmitted from other TP02 units.
When program is in execution, the user can ret urn to system menu by pressing Escape/Exit (Esc) key
for 5 seconds.
Communication Connection
TP02G may connect to a PC by using connection able DVPACAB515
TO PC (R S-232)
5
9
6
1
TO TP02 / 0 4G
PC COM Port
9 PIN D -SUB f emale
TP02G may connect to a DVP-PLC by using connection cable DVPACAB215/DVPACAB230/
DVPACAB2A30
DVPACAB215/DVPACAB230
13
14
9
6
25 P IN D- SUB
1
5
1
9 PI N D-S UB
DVPACAB2A30
5
9
6
1
TO P LC
TO PLC
MIN I DIN TER MINAL
PC / T P CO M Po rt PLC COM 1 Po rt
PC / T P CO M Po rt
Rx 2
Tx 3
GND 5
Tx
Rx 3
GND 7
Tx 3
Rx 2
GND 5
2
4
5
6
8
20
7
8
1
4
6
TP02 / 04G COM Port
9 PIN D -SUB f emale
3 Tx
2 Rx
5 GND
x
2
5 T x
8 G ND
8
1,2 5V
PLC COM 1 Po rt
8 PI N MIN I DI N9 P IN D- SUB f ema le
2
x
5 T x
1,2 5V
背面介紹
外觀尺寸
正面圖
俯視圖
(
(
單位:
單位:
mm)
mm)
30.50 [ 1.20]
5-Pin
97.0 0 [3.8 2]
端子座
RS-232
/
線徑:
12-24 AWG /
147 .00 [5. 79]
扭力:
4.5 lb-inch
嵌入開孔尺寸
(
單位:
mm)
右側圖
(
單位:
mm)
1
345
6
7
1
345
安裝方式
人機介面安裝於控制盤的方法,請直接將人機由盤面的正面直接放入即可(嵌入式),若要固定更牢固,可再利
用原廠包裝附件之固定架,嵌入後蓋直接四端凹槽處固定,並上、下平均鎖緊面板固定螺絲即可,如下圖為正確
安裝:( 固定螺絲時請以扭力:
注意:該安裝的平面必須是要適用
4-5 (kg-cm)
鎖緊,請勿超過此範圍以免破壞面板)
Type 4
室內使用或相等條件的配電盤外殼。

嵌入式
隔板厚度:
0.5 ~ 9.0m m
規格
功能規格
顯
示
幕
項目
TP02G-AS1
螢幕
STN-LCD
色彩
背光
解析度
16032 點
顯示範圍
72mm (W) 22mm (H)
對比調整
15
語言字型
字型大小
ASCII:58, 88, 812, 816
單色
背光自動關閉設定範圍
(設定值0為不關閉)
(在常溫
25°C
下壽命約5萬小時)
段明暗調整
ASCII
台灣:(
中國:(
:文字(包含歐洲字型)
BIG 5
碼)繁體字型
GB2324-80
58
88
812
816
碼)簡體字型
1 ~ 99分鐘
英文字
中文字
中文字
中文字
258字
168字
165字
164字
警示指示燈(紅燈) 電源啟動指示(亮/滅三次)/通訊不通警示/使用者程式指定
RS-232
指示燈(黃燈) 傳送程式及使用
RS-485
指示燈(綠燈) 使用
程式記憶
256KB
系統
RAM 32K Byte
外
部
介
面
串列通訊埠(
擴充通訊埠(
擴充槽
5Pin
脫落式端子
COM1)
COM2)
非同步傳送方式:
資料長度:7或8個位元
停止位元:1或2個位元
極性:
傳送速度:
更新韌體版本
非同步傳送方式:
資料長度:7或8個位元
停止位元:1或2個位元
極性:
傳送速度:
程式複製卡插槽
包含直流電源
RS-232
RS-485
通訊時持續閃爍
快閃記憶體
RS-232
None/Odd/Even
4,800 bps ~ 115,200 bps
RS-485
None/Odd/Even
4,800 bps ~ 115,200 bps
24V
通訊時持續閃爍
輸入及
RS-485
通訊輸入
選項
兩台
TP02
可互相傳送程式和資料,內含兩個子選單:
1
拷貝程式
:傳送程式;
當互傳程式和資料時,需先設定一台為接收程式模式,再設另一台為傳送程式模式,使用
擴充通訊埠(
用來更改
1.
2.
3.
TP02設定
4.
5.
6.
7.
8.
依據
PLC連線
1. 使用TP02
2.
~
使用連接電纜線
連線
~
執行
取消
使用連接電纜線
執行
程式
通訊連接線配線圖
TP
程式規劃
ON PC ( RS-23 2)
5
9
6
1
TP與DVP-PLC
2
:接收程式
COM2)RS-485
TP02
的內容值,內含8個子選項,分述如下:
通訊協定:可設定「
明暗對比:調整
背光省電:調整綠色背光
鐘即代表背光
TP02
LCM
螢幕顯示的對比亮度。
LED
永遠開啟。
蜂鳴器:設定蜂鳴器為正常模式或靜音模式。
語系設定:可設定使用語言為英文、繁體中文、簡體中文或使用者自定。
密碼設定:設定新密碼及是否啟用密碼功能,若啟用密碼功能則在進入任一項系統選單
指令,
會要求
開機畫面:選
由
輸入密碼。密碼出廠設定值為
擇
TP02
TPEditor
軟體設計下載至
內定,會顯示
通訊燈:可選擇通訊時指示燈是否閃爍
使用者設定
之
PLC
控制埠有
之
串列通訊埠(
接電纜線連接
使用擴充通訊埠(
口
。
啟動從
(
Esc
PLC之RS-232C
COM2)RS-485
TPEditor
)
按住5秒後回到
下載或
DVPACAB530
ON TP0 4G
6
9
5
DVPACAB215/DVPACAB230/DVPACAB2A30
DVPACAB215/DVPACAB230
PC TP 02/04G
或
13
14
9
6
25 PIN D-SUB
1
5
1
9 PIN D-SUB
8 PIN MINI DIN
ON PLC
DVPACAB2A30
說明
,請以雙絞線從擴充通訊埠連接兩台
站號」及「
RS-232
」、「
RS-485
」通訊內容。
LED
自動關閉的時間,設定範圍
1234。
TP02
內定的開機畫面,選擇使用者自定,使用者可
TP02
,顯示自訂開機畫面。
RS-232/RS-485
下列2種選擇
COM1)RS-232
程式通訊輸出入口。
同時開啟或關閉。
:
,選用
DVPACAB215或DVPACAB230
,請以雙絞線從擴充通訊埠連接
其他
TP02
傳送的應用程式,當進入執行程式後可
系統選單。
PC COM Port
9 PIN D-SUB female
Rx 2
Tx 3
GND 5
PC/H MI COM Port PLC COM1 Port
Tx 2
GND 7
6
4
8
5
20
PC/H MI COM Port PLC COM1 Port
Tx 3
Rx 2
GND 5
1
7
4
8
6
TP02。
00~99
分鐘,若設定為00分
PLC之RS-485
TP02/04G COM Port
9 PIN D-SUB female
3 Tx
2 Rx
5 GND
4 Rx
5 TxRx 3
8 GND
1,2 5V
4 Rx
5 Tx
8 GND
1,2 5V
5
5
2
經由退出
12
4
678
1
4
678
背面介绍
外观尺寸
正面图
連
通訊
/
3
3
俯视图
右侧图
安装方式
人机界面安装于控制盘的方法,请直接将人机由盘面的正面直接放入即可(嵌入式),若要固定更牢固,可再利
用原厂包装附件的固定架,嵌入后盖直接四端凹槽处固定,并上、下平均锁紧面板固定螺丝即可,如下图为正确
安装:( 固定螺丝时请以扭力:
注意:该安装的平面必须是要适用
(
(
(
单位:
单位:
单位:
mm)
mm)
mm)
30.50 [1.20]
RS-232
5-Pin
端子座
/
线径:
97.00 [3.82]
85.00 [ 3.35]
4-5 (kg-cm)
锁紧,请勿超过此范围以免破坏面板)
Type 4
室内使用或相等条件的配电盘外壳。
12-24 AWG /
147.0 0 [5.79]
嵌入开孔尺寸
擴充槽
扭力:
4.5 lb-inch
(
单位:
电气规格
项目/机型
TP02G-AS1
通讯界面
Com1:RS-232 Com2:RS-485
前面板防水等级
硬件使用温度
硬件储藏温度
耐震动
耐冲击
RF
静电放电测试
耐RF辐射度测试
高频瞬时测试
重量/外型尺寸
冷却方式
密碼功能說明
1.
当使用者进入
以此组万用码解除设定,但
2.
用功能键
F0
F1
F2
mm)
F3
F4
F5
F6
F7
F8
F9
硬件操作介紹
欲启动
按住退出/取消键(
下载程序
上传程序
IP65/NEMA4
0 ~ 50°C
;相对湿度
20-90% RH
-20 ~ 60°C
0.5mm位移, 10-55Hz, X, Y, Z
10G, 11ms从X, Y, Z
辐射测试
CISPR22, Class A
EN61000-4-2/1995
EN61000-4-3/1995
EN61000-4-4/1995
0. 24kg; 147×97×35.5mm (宽(W) ×高(H)×厚(D))
TP02
F0 ~ F9
:将依序输入
:将依序输入
:将依序输入
:将依序输入
:将依序输入
:只能输入数字
:只能输入数字
:只能输入数字
:只能输入数字
:只能输入数字
TP02
需输入
选项
空气对流自然冷却
设定的密码设定选项启用密码后忘记密码时,有一组万用码
TP02
输入密码字元,可输入数字
0→A→B→C→D→E→F→0
1→G→H→I→J→K→1
2→L→M→N→O→P→2
3→Q→R→S→T→U→V→3
4→W→X→Y→Z→4
内程序会全部被清除,且
0 ~ 9
循环。
循环。
循环。
循环。
循环。
5
6
7
8
9
24V
直流电源,接上电源之后,会先进入开机画面,接着即进入使用者所编辑的应用程序,
Esc)5
秒后,可回到系统菜单,系统菜单有五个主选项:
从电脑
TPEditor
DVPACAB530
从
TP02
用
DVPACAB530
软件下传应用程序至
连接电缆线连接。
上传应用程序至电脑
连接电缆线连接。
(不可凝结)
三方向各两小时
三方向各三次
、英文字母
TPEditor
8888
TP02
设定将回归出厂值,请谨慎使用。
A ~ Z
,方法如下:
说明
TP02
,使用串行通讯端口(
软件,使用串行通讯端口(
,任何使用者的密码皆可
COM1)RS-232
COM1)RS-232
,请选用
,请选
電氣規格
通訊介面
前面板防水等級
硬體使用溫度
硬體儲藏溫度
耐震動
耐衝擊
RF
靜電放電測試
耐RF輻射度測試
高頻暫態測試
重量/外型尺寸
冷卻方式
1.
當使用者進入
以此組萬用碼解除設定,但
2.
用功能鍵
F0
F1
F2
F3
F4
F5
F6
F7
F8
F9
欲啟動
按住退出/取消鍵(
下載程式
上傳程式
項目/機型
TP02G-AS1
Com1:RS-232 Com2:RS-485
IP65/NEMA4
0 ~ 50°C
-20 ~ 60°C
0.5mm位移, 10-55Hz, X, Y, Z
10G, 11ms從X, Y, Z
輻射測試
CISPR22, Class A
EN61000-4-2/1995
EN61000-4-3/1995
EN61000-4-4/1995
0.24kg; 147×97×35.5mm (寬(W) ×高(H)×厚(D))
密碼功能說明
TP02
F0 ~ F9
:將依序輸入
:將依序輸入
:將依序輸入
:將依序輸入
:將依序輸入
:只能輸入數字
:只能輸入數字
:只能輸入數字
:只能輸入數字
:只能輸入數字
硬體操作介紹
TP02
需輸入
選項
空氣對流自然冷卻
設定之密碼設定選項啟用密碼後忘記密碼時,有一組萬用碼
TP02
輸入密碼字元,可輸入數字
0→A→B→C→D→E→F→0
1→G→H→I→J→K→1
2→L→M→N→O→P→2
3→Q→R→S→T→U→V→3
4→W→X→Y→Z→4
5
6
7
8
9
24V
直流電源,接上電源之後,會先進入開機畫面,接著即進入使用者所編輯的應用程式,
Esc)5
秒後,可回到系統選單,系統選單有五個主選項:
從電腦
TPEditor
DVPACAB530
從
TP02
上傳應用程式至電腦
DVPACAB530
;相對濕度
20-90% RH
三方向各兩小時
三方向各三次
內程式會全部被清除,且
0 ~ 9
、英文字母
循環。
循環。
循環。
循環。
循環。
連接電纜線連接。
連接電纜線連接。
軟體下傳應用程式至
TPEditor
(不可凝結)
TP02
設定將回歸出廠值,請謹慎使用。
A ~ Z
,方法如下:
說明
TP02
,使用串列通訊埠(
軟體,使用串列通訊埠(
8888
,任何使用者之密碼皆可
COM1)RS-232
COM1)RS-232
,請選用
,請選用
两台
TP02
简体中文
注意事項
请在使用之前,详细阅读本使用说明书。
实施配线,务必关闭电源。
本机显示操作面板防水,但对油污或具腐蚀性的液体不具防护作用,避免以尖锐的物品刮伤面板使用时请注
意。
本机输入电源为直流
再次确认电源配线。
输入电源切断后,一分钟之内,请勿触摸内部电路。请勿在上电时触摸任何端子。
本体上的接地端子
利用原厂包装附件的固定架,锁紧面板固定螺丝时,请勿太紧以免造成机壳损坏。
產品簡介
产品外观及各部介绍
面板功能说明
面板元件
警示指示灯(红灯)
RS-232
指示灯(黄灯) 传送程序及使用
RS-485
指示灯(绿灯) 使用
退出/取消键
命令操作键
输入键
数值键及功能键
24V
,不可连接于
务必正确的接地,可提高产品抗噪声能力。
LCM
显示 区
退出 取 消 键
/
状态一:当启动电源时,指示灯慢慢开始闪烁三次。
状态二:当异常状态发生,指示灯会重复持续亮一秒并发出警报声。
RS-485
输入值错误时可按此键,删除文字叙述等。
UP/Pg Up
Pg Dn/DOWN
Left
:此键为左方向键,可作为选择数值位置操作。
Right
:此键为右方向键。可作为选择数值位置操作。
当输入值确认正确无误时,即可按下此键。
F0/0
:可作为0的常数输入键,也可由使用者定义其个别功能
F1/1
:可作为1的常数输入键,也可由使用者定义其个别功能
F2/2
:可作为2的常数输入键,也可由使用者定义其个别功能
F3/3
:可作为3的常数输入键,也可由使用者定义其个别功能
F4/4
:可作为4的常数输入键,也可由使用者定义其个别功能
F5/5
:可作为5的常数输入键,也可由使用者定义其个别功能
F6/6
:可作为6的常数输入键,也可由使用者定义其个别功能
F7/7
:可作为7的常数输入键,也可由使用者定义其个别功能
F8/8
:可作为8的常数输入键,也可由使用者定义其个别功能
F9/9
:可作为9的常数输入键,也可由使用者定义其个别功能
RS-485
通讯口信号端,否则可能造成严重的损坏,因此请在上电之前
RS-232
通讯时持续闪烁。
通讯时持续闪烁。
:此键为向上方向键,可作为数值递增输入或换至上页等操作。
:此键为向下方向键,可作为数值递减输入或换至下页等操作。
警示 指示 灯
RS- 232
指示 灯
RS- 485
指示 灯
数值 键及 功能 键
命令 造作 键
输入键
F0。
F1。
F2。
F3。
F4。
F5。
F6。
F7。
F8。
F9。
说明
嵌入式
隔板厚度:
0.5 ~ 9.0m m
規格
功能规格
显
示
屏
程序存储
系统
外
部
界
面
项目
屏幕
STN-LCD
色彩
背光
分辨率
16032 点
显示范围
72mm (W) 22mm (H)
对比调整
15
语言字体
字体大小
ASCII:58, 88, 812, 816
警示指示灯(红灯) 电源启动指示(亮/灭三次
RS-232
指示灯(黄灯) 传送程序及使用
RS-485
指示灯(绿灯) 使用
256 KB
RAM 32K Byte
串行通讯端口
扩展通讯端口
扩展槽
5Pin
脱落式端子
单色
背光自动关闭设定范围
(设定值0为不关闭)(在常温
段明暗调整
ASCII
台湾:(
中国:(
非同步传送方式:
数据长度:7或8个位
停止位:1或2个位
(
COM1)
极性:
传送速度:
更新韧体版本
非同步传送方式:
数据长度:7或8个位
(
COM2)
停止位:1或2个位
极性:
传送速度:
程序复制卡插槽
包含直流电源
:文字(包含欧洲字体)
RS-485
快闪存储体
None/Odd/Even
None/Odd/Even
1 ~ 99分钟
58
88
812
816
BIG 5
码)繁体字体
GB2324-80
码)简体字体
RS-232
通讯时持续闪烁
RS-232
4,800 bps ~ 115,200 bps
RS-485
4,800 bps ~ 115,200 bps
24V
输入及
25°C
下寿命约5万小时)
英文字
258字
中文字
168字
中文字
165字
中文字
164字
)/
通讯不通警示
通讯时持续闪烁
RS-485
通讯输入
TP02G-AS1
/
使用者程序指定
拷贝程序
TP02设定
PLC连线
执行程序
通訊連接線配線圖
TP
程序规划
~
使用连接电缆线
ON PC (RS- 232)
5
9
6
1
TP与DVP-PLC
连线
~
DVPACAB215/DVPACAB230
PC T P02/0 4G
或
13
25 PI N D-S UB
14
1
5
9
6
1
9 PIN D -SU B
DVPACAB2A30
可互相传送程序和数据,内含两个子菜单:
1
:传送程序;
当互传程序和数据时,需先设定一台为接收程序模式,再设另一台为传送程序模式,使用
扩展通讯端口(
用来更改
1.
2.
3.
4.
5.
6.
7.
8.
依据使用者设定的
1. 使用TP02
2.
执行启动从
消(
2
:接收程序
COM2)RS-485
TP02
的内容值,内含8个子选项,分述如下:
通讯协议:可设定
明暗对比:调整
背光省电:调整绿色背光
分钟即代表背光
,请以双绞线从扩展通讯端口连接两台
“TP02站号” 及 “RS-232” “RS-485”
LCM
屏幕显示的对比亮度。
LED
LED
自动关闭的时间,设定范围00 ~ 99分钟,若设定为
永远开启。
蜂鸣器:设定蜂鸣器为正常模式或静音模式。
语言设定:可设定使用语言为英文、繁体中文、简体中文或使用者自定。
密码设定:设定新密码及是否启用密码功能,若启用密码功能则在进入任一项系统菜单
指令,会要求输入密码。密码出厂设定值为
开机画面:选择
由
TPEditor
TP02
内定,会显示
软件设计下载至
TP02
TP02
,显示自订开机画面。
通讯灯:可选择通讯时指示灯是否闪烁
PLC
控制端口有下列2种选择:
的串行通讯端口
接电缆线连接
使用扩展通讯端口
通讯口。
TPEditor
Esc
)按住5秒后回到系统菜单。
(
PLC的RS-232C
(
COM2) RS-485
下载或其他
COM1) RS-232
程序通讯输出入口。
,请以双绞线从扩展通讯端口连接
TP02
传送的应用程序,当进入执行程序后可经由退出/取
DVPACAB530
ON TP04G
9 PIN D-S UB femal e
使用连接电缆线
DVPACAB215/DVPACAB230/DVPACAB2A30
PC/ HMI C OM Po rt PLC C OM1 P ort
8 PIN MINI D IN
ON P LC
PC/ HMI C OM Por t PLC C OM1 Port
TP02。
通讯内容。
1234。
内定的开机画面,选择使用者自定,使用者可
RS-232/RS-485
同时开启或关闭。
,选用
DVPACAB215或DVPACAB230
PLC的RS-485
PC COM Por t
Rx 2
Tx 3
GND 5
6
8
20
1
4
6
Tx 2
GND 7
4
5
Tx 3
Rx 2
GND 5
7
8
TP02/ 04G COM Po rt
9 PIN D-S UB femal e
3 Tx
2 Rx
5 GND
8 PIN M INI DIN25 PI N D-SU B fem ale
4 Rx
2
5 TxRx 3
5
8 GN D
1,2 5V
8 PIN M INI DIN9 PIN D -SUB f ema le
4 Rx
5 Tx
8 GN D
1,2 5V
1
3
4
12
345
00
连