Delta SIG110LED User Manual

INSTALLATION AND OPERATING INSTRUCTIONS
VENTILATION FAN/LED LIGHT/ LED NIGHT-LIGHT
READ AND SAVE THESE INSTRUCTIONS
GENERAL SAFETY INFORMATION
MODEL SIG110LED
Page 1.
1. Make sure that the electric service supply voltage is AC 120V, 60Hz.
2. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupational Safety and Health Act (OSH Act).
3. Always disconnect the power source before working on or near the ventilating fan, motor or junction box.
4. Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals or other objects.
5. Do not kink the power cord.
6. Do not install the unit where ducts are Fig. A.
7. Provide suction parts with proper ventilation.
8. This unit is UL listed for use over a bathtub or shower when installed in a GFCI (Ground Fault Circuit Interrupter) protected branch circuit.
9. These ventilating fans are intended for residential usage only.
congured as shown in
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufactu
2. Before servicing or cleaning the unit, switch the power o at the service panel and lock the service disconnecting means to prevent the power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by qualied person(s) in accordance with all applicable codes and standards, including re-rated c
4. Sucient air is needed for proper combustion and exhausting of gases through the ue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and local code authorities.
5. When cutting or drilling into a wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducte outdoors.
7. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI – protected branch circuit.
rer.
onstruction.
d ventilating fans must always be vented to the
8. Do not use this unit with any other solid-state control device. Solid-state controls may cause harmonic distortion, which can cause a motor humming noise.
9. NEVER place a switch where it can be reached from a tub or shower.
10. Not to be installed in a ceiling thermally insulated to a value
ater than R40. (This is required for installation in Canada
gre only).
11. Do not open/disassemble the LED light engine.
Turning angle too large Duct shrink
ydob eht raen woblEswoble ynam ooT
Body
Fig. A
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. Not for use in cooking areas. (Fig. B)
3. This product must properly connect to the grounding conductor of the supply circuit.
4. To reduce the risk of injury to persons, install the fan at least
8.2 feet (2.5 m) above the oor.
Cooking area
Do not install above or
inside this area
45
°
Cooking Equipment
Fig. B
45
°
floor
SUPPLIED ACCESSORIES
Part name Appearance Quantity
Grille
Tapping Screw
4x25)
(ψ
Screw
#8-32x1/4”
Duct connector 1
Duct Screw
(M4x12)
13”(318.5)
13”(318.5)
Inches (mm)
1
4
4
1
2
2
1. Using suspension brackets
1-1. Sliding suspension brackets are provided to allow for
positioning of the housing anyw here between joists up to a span of 24”.
1-2. Insert the suspension brackets into the channels on the
housing. Make sure the tabs face up as shown. (Fig. C)
1-3. Extend the suspension brackets to t the width of the joists.
Hold the fan in place by wrapping the suspension bracket tabs around the bottom of the joist. Make sure the fan body is level and perpendicular to the joist. (Fig. D & E)
1-4. Ensure that the distance between the ceiling and fan body is
appropriate for mounting the grille.
1-5. Secure the suspension brackets to the joists with nails or by
using the tapping screws ( 4x25) through holes near nails.
1-6. Secure the suspension bracket to the fan body using the
screws (#8-32 x 1/4").
1-7. Follow steps 2 to 6 of the installation to complete the
installation work.
INSTALLATIONS
Proper insulation around the fan to minimize building heat loss and gain.
Roof cap (with built-in
Short piece of exible duct helps alignment and absorbs sound
Fan housing
Seal gap around housing
Caulk termination to duct
damper)
Wall cap (with built-in damper)
Attach Duct Connector Option 1. Attach the duct connector from outside, and secure using the duct screw (M4X12).
Inse rt tab into slot i n ho using
Duc t screw (M4X12) from Parts B ag
Suspension Bracket I
Suspension Bracket II
Body
MODEL SIG110LED
ψ
Tab
Fig. C
Page 2.
Option 2. Attach the duct connector from the housing can inside, and secure using the duct screw (M4X12).
Duct sc rew(M4X12) from Pa rts Bag
Pull existing ductwork into Housi ng
Insert tab into slot in Hous ing
Note: Remove the tape from the damper and adaptor before installation.
Fig. D
Fig. E