Delta SIG80L, SIG110DL, SIG110HL, SIG110L User Manual

MODELS
L
Page 1.
INSTALLATION AND OPERATING INSTRUCTIONS
VENTILATION FAN / LIGHT / NIGHT LIGHT
GENERAL SAFETY INFORMATION
1. Make sure that the electric service supply voltage is AC 120V, 60Hz.
2. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA).
3. Always disconnect the power source before working on or near the ventilating fan, motor or junction box.
4. Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals or other objects.
5. Do not kink the power cord.
6. Do not install the unit where ducts are congured as shown in Fig. A.
7. Provide suction parts with proper ventilation.
8. This unit is UL listed for use over a bathtub or shower when installed in a GFCI protected branch circuit.
9. These ventilating fans are intended for residential usage only.
7. If this unit will be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
8. Do not use this unit with any other solid-state control devices. Solid-state control devices may cause harmonic distortion, which can cause a motor humming noi
9. NEVER place a switch where it can be reached from a tub or shower.
10. (Required for installation in Canada only). Do not install in a ceiling thermally insulated to a value greater than R40.
Turning angle too large Duct shrink
Too many elbows Elbow near the body
SIG80L / SIG110L / SIG110HL / SIG110D
se.
Body
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have q manufacturer.
2. Before servicing or cleaning the unit, switch the power o on the service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by qualied person(s) in accordance with all applicable codes an
4. Sucient air is needed for proper combustion and exhausting of gases through the ue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and local code authorities.
5. When cutting or drilling into the wall or ceiling, do not dam
6. Ducted fans must always be vented to the outdoors.
d standards, including re-rated construction.
age electrical wiring and other hidden utilities.
uestions, contact the
Fig. A
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. Not for use in cooking areas. (Fig. B)
3. This product must properly connect to the grounding conductor of the supply circuit.
4. To reduce th least 7 feet (2.1m) above the oor.
e risk of injury to persons, install the fan at
Cooking area
Do not install above or
inside this area
45°
Cooking Equipment
45°
floor
Fig. B
MODELS
SIG80L / SIG110L / SIG110HL / SIG110D
L
Page 2.
SUPPLIED ACCESSORIES
Part name Appearance Quantity
Grille 1
Tapping screw
4x25)
Screw
#8-32x1/4”
Grille bracket screw
(M4x6)
Grille screw
(M4x30)
Nut
(M4x4.4)
Duct connector 1
Duct screw
(M4x12)
Suspension bracket I
13 (318.5)
Suspension bracket II
13”(318.5)
Grille bracket
9.68”
GU24 base bulb lamp
(26W)
E12 base bulb lamp
(4W)
Inches (mm)
INSTALLATIONS
Attach Duct Connector Option 1. Attach the duct connector from the outside, and secure using the duct screw (M4X12).
Insert tab into slot in housing
Duct screw(M4X12) from Parts Bag
Note: Remove the tape from the damper and adaptor before installation.
1. Using suspension brackets
1-1. Sliding suspension brackets are available to allow the
4
4
1
housing to be positioned between joists up to a span of 24”.
1-2. Insert the suspension brackets into the channels on the
housing. Make sure the tabs face up as shown. (Fig. C)
1-3. Extend the suspension brackets to t the width of the
joists. Hold the fan in place by wrapping the suspension
2
bracket tabs around the bottom of the joist. the fan body is level and perpendicular to the joist. (Fig. D
Make sure
& E)
1
1-4. Ensure that the distance between the ceiling and fan
body is appropriate for mounting the grille.
1-5. Secure the suspension brackets to the joists with nails or
by using the tapping screws (ψ
4x25) through holes near
nails.
1
2
1-6. Secure the suspension bracket to the fan body using the
screws (#8-32 x 1/4").
1-7. Follow steps 2 to 6 of the installation guide to complete
2
1
1
1
installation.
Body
Suspension Bracket I
Suspension Bracket II
Tab
Fig. C
Option 2. Attach the duct connector from the housing can inside, and secure using the duct screw (M4X12).
Duct screw(M4X12) from Parts Bag
Pull existing ductwork into Housing
Insert tab into slot in Housing
Fig. D
Fig. E