Delta FFB0412EHN User Manual

UH
GH
EH
FFB0412XN-C
(M /MIN)
32.0
(IN H O)
Air Pressure
0.45
.20
8.0
(mm H O)
12
00
Air Flow
16.0 24.0
.60.40 .80
36
24
0.90
1.35
60
48
1.80
2.25
72
2.70
1.0
(CFM)
3
(INCH)
UNIT :
mm
LABEL
40.0±0.5
32.0±0.3
(1.260±0.012)
(1.575±0.020)
(1.575±0.020)
40.0±0.5
32.0±0.3 (1.260±0.012)
(8-Ø0.138±0.012)
8-Ø3.5±0.3
338.0±10.0
(13.310±0.394)
10.0
(0.394)
(1.102±0.020)
28.0±0.5
(0.157±0.016)
4.0±0.4
(INCH)
UNIT :
mm
(1.512)
38.4
(1.512)
38.4
(1.260)
32.0
(1.260)
32.0
38.4 (1.512)
32.0 (1.260)
38.4 (1.512)
32.0 (1.260)
Ø40.8
(Ø1.606
Ø40.9
(Ø1.610)
(4-Ø0.138)
4-Ø3.5
(4-Ø0.138)
4-Ø3.5
OUTLET SIDE
INLET SIDE
http://www.deltaww.com
FFB
DIMENSIONS DRAWING
40 x 40 x 28 MM SERIES
*
Bearing Type
Ball Bearings
*
Material
Impeller & Frame : Plastic(UL 94V-0)
*
Lead Wires :
UL 1061 AWG #26 OR Equivalent Red Wire Positive(+) Black Wire Negative(-)
*
Weight : 47g (1.66 OZ)
MODEL
Rated
Voltage
Operating
Voltage
Range
Rated
Current
Rated
Input
Power
Speed
Maximum
Air Flow
Maximum
Air Pressure
Noise
PART NO.
REV.
FUNCTION VDC VDC Amp Watt R.P.M. m3 /min CFM mmH2O IN H2O dB-A
FFB0412EHN -C -R00 / -F00 12 5.5 to 13.2 0.33 3.96 14500 0.576 20.34 31.28 1.232 53.0
FFB0412GHN -C -R00 / -F00 12 5.5 to 13.2 0.50 6.00 16500 0.662 23.39 41.6 1.638 56.0
FFB0412UHN -C -R00 / -F00 12 5.5 to 13.2 0.65 7.80 18500 0.766 27.05 53.63 2.111 58.5
* Function type is optional.
* The max. air ow and the speed are measured in free air ; max. air pressure is measured at zero air ow. * Noise is measured in anechoic chamber in free air, one meter from intake side.
* All readings are typical values at rated voltage.
* Specications are subject to change without notice.
P & Q CURVE
(AT RATED VOLTAGE)
MOUNTING PANEL CUTOUT
Loading...