The user manual is suitable for DX-2300LN-WW. If you need to use the Delta DX-2300 series products in China areas,
please refer to the model na m e DX-2300LN-CN on the Delta website, or contact our branch offices or distributors.
FCC Interference Statement
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation.
This equipment generates radio frequency signal and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the e quipmen t off a nd on, t he user is e ncourage d to try to corre ct the inter feren ce by one or more o f
the following measures:
---Reorient or relocate the receiving antenna.
---Increase the separation between the equipment and receiver.
---Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
---Consult the dealer or an experienced radio/TV technician for help.
CE Declaration of Conformity
In accordance with the Directives 2004/108/EC*, 2014/30/EU, 2006/95/EC* and 2014/35/EU. The test record, data
evaluation and DX-2300 Series configurations represented herein are true and accurate under the standards herein
specified.
Disclaimers and Limitation of Liabilities
To the maximum extent permitted by law and regardless DELTA be aware or has been advised of the possibility of these
damages, DELTA is not liable to any user or anyone else for: (a) any loss of use, data, reputation, goodwill, credit,
opportunity, economy or profits, whether or not foreseeable; (b) any special, incidental, indirect, consequential, or punitive
damages whatsoever; (c) any losses or damages based on any t heory of liab ili ty, including breach of contract or w ar ranty,
negligence or other tortious action; (d) any losses or damages resulting from use or unable to use the systems or devices
to which the Software or Services are incorporated or co-operated; and (e) any losses or damages arising from any other
claim or in connection with the use of or access to the Software or Services.
1-2
Chapter 1 Pr oduct Introducti on
1_
1.1 Product Overview
The DX-2300LN-WW is a wired industrial router, an Internet of Things wired communication product of industrial grade.
The product is equipped with multiple application interfaces, including Ethernet interface, RS232 serial interface and
RS485 serial interface, and thus can satisfy the user’s various different application demands.
The product supports DIACloud platform services, and by this platform, convenient and efficient point-to-point connection
with the router, safe and reliable data transmission, remote device management and configuration, remote firmware
upgrading, remote maintenance and other functions can be realized, so as to save the cost of device operation and
maintenance for users.
The product can be widely used in the fields requiring mobile network interconnection, such as industrial automation,
smart home, intelligent building, smart power grids, video surveillance, intelligent self-service and intelligent
transportation.
1.1.1 Network Design
Connect the intelligent devices at different sites to the Internet via the DX-2300LN-WW. The DX-2300LN-WW allows the
point-to-point connection throu gh DIACloud platform. In addition to safe and reliable data transmission, it can save the
cost of purchasing and maintaining VPN dev ice .
The maintenance personnel can realize remote maintenance and management of the device through DIACloud platform
whenever and wherever possi ble, which can ensure safe and reliable d ata transmission, and als o ca n save op er ati on an d
management cost of the device for users.
1-3
DX-2300 Series Industrial Ethernet Cloud Router
_1
1.1.2 Features
Device support various connection method in WAN port, such as the static IP, DHCP client.
Provide dual serial port (RS232 & RS485) and LAN port connectivity.
Build in Watch-Dog.
NTP server built in RTC.
Local and remote firmware upgrade.
Support Firewall: Stateful Packet Inspection (SPI), Prevent Denial of Service (DoS) Attacks, NAT (Network Address
Translation), Port Trigging, Port Mapping, IP Address Filtering, MAC Address Filtering, URL Filtering, DHCP Server,
Dynamic DNS, Static Routes, Demilitarized Zone (DMZ)
TCP/IP, UDP, ICMP, DHCP, HTTP, DNS, SSH protocol
Modbus TCP and Modbus RTU / ASCII protocol
SMS alarm functions, users can customize the alarm condition
Provide task schedule manag emen t
Local log and remote log server
Configuration backup and importing
Network data flow statistic
Networking failure diagnostic
DIACloud platform servi ces that can rea lize safe poi nt -to-point data transmission, remote device configuration and
management, firmware upgrading, and support batch configuration and upgrading of multiple devices
1-4
1_
1.1.3 Front Panel Ports and LEDs
Reset the Router: W ith the router powered on, press the Reset button and release the button right
RS232 Port
POWER LED
READY LED
RS232 LED
RS485 LED
SD LED
WAN Port
LAN Port
Chapter 1 Pr oduct Introducti on
SD Card Slot
Reset Button
1.1.4 Bottom Panel
Power Port
RS485 Port
Grounding
Notice
This router’s reset button is on the front panel. By pressing the Reset button, users can reset the router or
reset the router to factory default settings. See the instruction below:
away.
1-5
DX-2300 Series Industrial Ethernet Cloud Router
_1
outer powered on, press and hold the Reset button for 3~6
With the router powered on, press and hold the Reset button until all the LEDs go out (except
er LED). Then release the button and wait the router to reboot to its factory default
Reset to Factory Defaults: With the r
seconds and then release the button.
Reset can only be done when the device is running properly.
the Pow
settings.
1.1.5Dimension
Unit = mm
1-6
Chapter 1 Pr oduct Introducti on
1_
1.2 Package Checklist
Unpack the package carefully and check the package contents. The package should contain the following items:
Verify that nothing is missing f r om t he DX-2300LN-WW p ac k age by us ing the check list abov e. If a ny item is
found missing or damaged, please contact your local sales representative for support.
2.2.4 Open Device Webpage ........................................................................................... 2-11
2-1
DX-2300 Series Industrial Ethernet C loud Router
2_
2.1 Web-based GUI Configuration
The DX-2300LN-WW Industrial Ethernet Cloud Router provides a friendly Web Browser Configuration for users to set up
and operate more intruitivly.
2.1.1 System Connection
First, connect the PC used for configuration with Ethernet interface of the router directly or through the switch/hub.
2.1.2 Default IP Address/Account/Password
The default domain name of router is www.diadevice.com, default IP address is 192.168.1.1. The initial account and
password is admin/admin
2.1.3 Local Network Setups
After the connection of the local computer and the router is done, you will need to set the network configruration for your
computer. There are 2 methods for the setting, we prefer you use the first one:
Obtain an IP address automatically by using the router as a DHCP server.
1. Open Network Connections by clicking the Start button , and then clicking Control Panel.
2. Under Network and Sharing Center, click View network connections.
3. Right-click the connection that you want to change, and then click Properties. If you're prompted for
an administrator password or confirmation, type the password or provide confirmation.
4. Click the Networking tab. Under This connection uses the following items, click either Internet Protocol
Version 4 (TCP/IPv4) or Internet Protocol Version 6 (TCP/IPv6), and then click Properties.
5. Click Obtain DNS server address auto mat ic ally an d then cli c k OK to get a DNS server address
automatically using DHCP.
2-2
Chapter 2 I ntroductio n to User Inte rface
2_
Set up the IP address manually.
(The IP address of the computer should be in the same network segment as the router’s.)
Since the router’s default IP address is 192.168.1.1 and the subnet mask is 255.255.255.0, the computer’s IP
address can be set between 192.168.1.2 to 192.168.1.254. However, you’ll need to make sure there are no IP
conflicts.
2-3
DX-2300 Series Industrial Ethernet C loud Router
2_
Here, we set the address to 192.168.1.10 and the default gateway to 192.168.1.1. For DNS, the usable DNS
address can be selected or the address can also be set to 192.168.1.1.
2.1.4 Logging in
1. Open your Internet Explorer browser and input LAN IP address (Default is 192.168.1.1) or the router’s domain name
(www.diadevice.com) in the search bar and then press Enter.
2. You’ll be prompted with the log-in page. Input the user name and the password (Default is admin/admin) and then
press Enter to log in to the setup page.
2-4
Chapter 2 I ntroductio n to User Inte rface
2_
Notice
3. After login, you can see the main selection area on the left hand side and the upper area of the page. The detailed
settings can be seen on the right hand side of the page.
Considerations of the ro uter L A N por t IP will be change after device is activated, after this
if you need login the web still, we prefer you use 192.168.1.1 and use the automatically
obtained IP address and DNS server for the computer
2.2 DIADevice
DIADevice is a tool for quickly configuring network devices. Users simply connect the DX device to the PC through the
network cable. This tool can be used to quickly and easily configure the network setting of the device and complete the
device binding DIACloud cloud account.
The DIADevice software is included in the latest DIACom software package. From the official website or sales staff to
obtain DIACom packag. DX-2300 below as an example on how to configure the device through DIADevice.
The following example uses DX-2300 to show you how to configure your device with DIADevice.
2-5
DX-2300 Series Industrial Ethernet C loud Router
2_
2.2.1 Device connection and detection
1. Connect the device to the power supply, and connect the device to the PC using a network cable. Plug the network
cable connected to the Internet into the WAN port of the device
2. Run DIADevice and click ‘Detect’ button
3.
After DIACom detects the device, it will automatically go to the login page, and the user needs to enter login
password on the login page.
2-6
Chapter 2 I ntroductio n to User Inte rface
2_
4. After passing the authenticatio n, the device information page is displayed, including the basic device information
(Device Name, S / N, firmware, LAN IP address), network status, WAN information, and cloud service information
2.2.2 Network Setting
This feature allows you to quickly configure your network in three steps.
1. Click “Network Setting”
2-7
DX-2300 Series Industrial Ethernet C loud Router
2_
2. The default is DHCP. If you can not connect to the Internet using auto-setup, please use manual settings.
3. Please confirm the network en v ironme nt and then decide whether to e nabl e HTTP Proxy. If you need to set up HTTP
PROXY, contact your IT staff.
2-8
Chapter 2 I ntroductio n to User Inte rface
2_
4. After the device successfully connected to the Internet, the connection was successful.
2.2.3 Bind Device
This feature allows you to quickly bind your device to the DIAcloud in three steps.
1. Click “Bind Device”
2-9
DX-2300 Series Industrial Ethernet C loud Router
2_
2. Enter the DIAcloud account number and password, and click Next.
3. After binding configuration is configured, click “Bind” to bind.
2-10
Chapter 2 I ntroductio n to User Inte rface
2_
Notice
4. If your device is successfully bound to the cloud, the following screen will appear
If the device has been bound to the cloud account, you need to switch to another cloud
account binding, you only need to repeat 1-3 steps and then enter the new cloud account
you need to bind
2.2.4 Open Device Webpage
. Click open device webpage button, the browser will open the device settings page, the user can set the parameters of
RS232 / 485 configuration.
2-11
DX-2300 Series Industrial Ethernet C loud Router
2_
2-12
3
Chapter 3 Functions
Table of Contents
3.1 Device Inform at ion .................................................................................... 3-3
3.1.1 Network Status ...................................................................................... 3-4
This page shows basic information on the Hardware/Software version and Resource Usage Information.
Hardware Version
Item Description
RTM Version
Release Date
S/N
Software Version
Item Description
RTM Version
Release Date
Current Version
Release to manufacturing version of the router
Hardware release date
Serial number of the router
Release to manufacturing version of the software
Software release date
Version number of the software currently used on the router
3-3
DX-2300 Series Industrial Ethernet Cloud Ro uter
_3
Upgrade Date
Upgrade time of the software currently used on the router
Resource Usage Information
Item Description
CPU Usage
Total Memory
Memory Used
Memory Usage
The CPU usage of current router
The total memory on the router
The memory currently used on the router.
The current ratio of the router usage
3.1.1 Network Statu s
This page shows basic information on Internet Information and LAN Status.
Internet Information includes the MAC Address, IP Address, Gateway Address, Primary DNS, Network Mask, WAN
Connection Mode, and Secondary DNS.
LAN Status includes the Device Name, IP Address, DHCP Server, MAC Address and Network Mask. When the DHCP
server is enabled, you can see more information, including the address lease time, start address and end address.
3-4
Chapter 3 Introduction to Functions
_3
3.1.2 Routing Table
This page shows basic information on the routing table, including the Destination, Gateway, Network Mask, HOPS and
Network Interface.
3.1.3 Local Log
This page shows logs of the router, including the System log, Warning lot and the Debug log. You can use the buttons on
the right hand side to refresh, clear or download the displayed logs.
3-5
DX-2300 Series Industrial Ethernet Cloud Ro uter
_3
3.1.4 Traffic Statistics
This page shows network traffic information of the router, including the data sent and received over WAN and LAN. You
can use the buttons on the right hand side to refresh or clear the traffic information.
3.1.5 Cloud Status
This page shows cloud server information of the router, including the Registration Status, Service Status, and Activated
Time.
3.1.6 Connected Device
This page shows information of the devices connected to the router, including the IP Address, Host Name, MAC Address.