Delta DPS-92BP Schematic

Power Supply CBA Top View
NOTE:
The voltage for parts in hot circuit is measured using hot GND as a common terminal.
CAUTION !
For continued protection against fire hazard, replace only with the same type fuse.
Because a hot chassis ground is present in the power supply circuit, an isolation transformer must be used when repairing. Also, in order to have the ability to increase the input slowly, when troubleshooting this type of power supply circuit, a variable isolation transformer is required.
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit. If Main Fuse (F1) is blown , check to see that all components in the power supply circuit are not defective before you connect the AC plug to the AC power supply. Otherwise it may cause some components in the power supply circuit to fail.
10-17
UPBPSPDEL006
Power Supply CBA Bottom View
NOTE:
The voltage for parts in hot circuit is measured using hot GND as a common terminal.
CAUTION !
For continued protection against fire hazard, replace only with the same type fuse.
Because a hot chassis ground is present in the power supply circuit, an isolation transformer must be used when repairing. Also, in order to have the ability to increase the input slowly, when troubleshooting this type of power supply circuit, a variable isolation transformer is required.
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit. If Main Fuse (F1) is blown , check to see that all components in the power supply circuit are not defective before you connect the AC plug to the AC power supply. Otherwise it may cause some components in the power supply circuit to fail.
10-18
UPBPSPDEL006