1. Read complete instructions and familiarize yourself with the illustrations before beginning.Plumber installation is recommended.
2. WARNING! SHUT OFF WA TER SUPPLIES BEFORE DISASSEMBLINGTHE TUB SHOWER VALVE.
3. Remove handle.
4. CAUTION! Mark the Rotational Limit Stop “RLS”(A) with a pen or pencil on the raised rib that aligns with the groove on the brass stop (B).
NOTE:after installing the new cartridge, its RLS must be in the same position (if this position provided the correct handle rotation previously).
See important information and RLS Adjustment on the back of this sheet (Steps 4.1, 4.2 and 4.3).
5. CAUTION!Pull off the RLS (A) and note the position of the raised stop (C) on the cap assembly that says “hot side”.The cartridge must alwa ys
be put back in this same position.The raised stop should always be located on the hot water inlet side so cold water will flow first. For normal
installations, the raised stop will be on the left.
6. Pull outside sleeve (D) off. Then, if necessary, slide the sleeve O-Ring (E) toward you until it stops at the raised brass section (F) on the
tub/shower body.Do not pull the sleeve O-Ring over the raised brass section.NOTE:when the sleev e is re-installed, it will slide on this O-Ring.
7. BE SURE WATER SUPPLIES ARE SHUT OFF!
8. Unscrew the brass bonnet (G).
9. Do not pry the cartridge out of the body with a screwdriver. Re-install the handle on brass stem (H) and rotate counterclockwise while
lifting the cartridge out of the two notches on the sides of the body.
10. CAUTION! Do not twist the Cap and Lower Housing of the New Cartridge to take it apart. If they are separated for any reason, be sure
they are locked back together by twisting them together until they snap back together.WARNING! Never take the Lower Housing Apart.
11. Install the cartridge with the raised stop on the cap (C) on the hot water inlet side (see Step 5).
12. Re-assemble the brass bonnet (G).
13. Slide on the outside sleeve (D) (see Step 6).
14. Remove and throw away the black retention plug (not illustrated) from the brass stem (H) at the top of the new cartridge.
15. Check for proper installation of the RLS (A) on the new cartridge by following Steps 4.1, 4.2 and 4.3 (on reverse side).
16. Re-install the handle then proceed to Step 17.
17. FLUSH YOUR SYSTEM.Turn handle to full on “hot and cold mix” position. Turn on water supplies.Check for leaks and let supply lines flush
for one minute without moving handle.If you have a showerhead, divert water to it and flush for 30 seconds.This will remove any debris from
the supply lines that can damage internal parts of the faucet and create leaks. BE SAFE! After you have finished the repair, turn on
tub/shower valve to make sure COLD WA TER FLOWS FIRST. If not, see Step 5.