Delta BreezRadiance RAD110LED Instructions Manual

VENTILATION FAN WITH
LED LIGHT AND HEATER
MODEL RAD110LED
TABLE OF CONTENTS
Package Contents
Important Instructions
Preparation
Assembly Instructions
Operating Instructions
Care and Maintenance
Dimensions
Product Specication
Troubleshooting
Warranty
2
3
4
5
9
9
10
11
11
12
12
READ AND SAVE THESE INSTRUCTIONS
Address: 46101 Fremont Boulevard, Fremont, CA 94538
US Toll Free Number: 1-888-979-9889
www.deltabreez.com
PACKAGE CONTENTS
l
PART DESCRIPTION QTY
1
Fan Body 1
1
2
3
(Images are not shown in actual scale)
Duct Connector 1
Grille 1
HARDWARE CONTENTS
2
A
× 4
Suspension Bracket
× 8
3
B
Wood Screw
(Ø 4 x 25 )
× 1
C
Short Machine Screw
( M4 x 5 )
2
IMPORTANT INSTRUCTIONS
l
When using electrical appliances, basic precautions should
always be followed to reduce the risk of re, electric shock,
and injury to persons, including the following:
• Read all instructions before installing or using this heater.
• Extreme caution is necessary when heater fan is used by or near unattended children, and / or persons with disabilities or limitations.
• Do not operate heater if it malfunctions. Disconnect power at service panel and have heater inspected by reputable electrician before reusing.
• Do not use outdoors.
• To disconnect heater, turn controls to OFF switch. Then, turn off the power to the heater circuit at the main disconnect panel.
• Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an
electric shock of re, or damage the heater.
To prevent a possible re, do not block air intakes or exhaust in any manner.
• A heater has hot and arcing or sparking parts inside. Do
not use it in areas where gasoline, paint, or ammable
vapors or liquids are used or stored.
• Use this heater only as described in this manual. Any other
use not recommended by the manufacturer may cause re,
electric shock or injury to persons.
SAVE THESE INSTRUCTIONS
Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage.
SAFETY INFORMATION
Please read and understand this entire manual before attempting to assemble, operate or install the product.
• Follow all local safety and electrical codes as well as NEC (National Electrical Code) and OSHA (Occupational Safety and Health Act).
• This unit must be properly grounded.
• Always disconnect the power supply prior to servicing the fan, motor or junction box.
• Do not bend or kink the power wires. Protect from sharp edges, oil, grease, hot surfaces, chemicals or other objects.
• Do not install over a tub or mount in a shower stall enclosure.
• Do not use to exhaust hazardous or explosive vapors.
• Do not install in a cooking area.
• Do not install this fan vertically in a wall.
• Use this unit in the manner intended by the manufacturer.
• If you have any questions, please call the manufacturer.
Installation work must be carried out by a qualied person(s) in accordance with all local and safety codes
including the rules for re-rated construction. For use in non-re rated installations only.
Sufcient air supply is required for proper combustion and the exhaustion of gases through the chimney (ue) of
fuel burning equipment to prevent back-drafting. See the standards of NFPA (National Fire Protection Association) and ASHRAE (American Society for Heating Refrigeration and Air Conditioning Engineers) and the local building code authorities.
• Exercise care to not damage existing wiring when cutting or drilling into walls or ceilings.
• Fans should always be vented to the exterior and in compliance with local codes.
• Do not use this fan with any solid state control device such as a dimmer switch. Solid-state controls may cause harmonic distortion, which can cause a motor humming noise.
• Prior to service or cleaning this unit, shut off power supply at the panel and lock to prevent the power from being turned on. If the panel cannot be locked, clearly mark the panel with a warning tag to prevent the power from being turned on.
• Do not install in a ceiling with insulation greater than R40. (This is required for installations in Canada only.)
• Duct work should be installed in a straight line with minimal bends.
• Duct work size must be a minimum of the discharge and should not be reduced. Reducing the duct size can increase fan noise.
• This ventilating bath fan is intended for residential use only in 1-2 family dwellings.
• Never place a switch where it can be reached from a tub or shower.
• Make sure that the electric service supply voltage is AC 120 V, 60 Hz.
• Always disconnect the power source before working on or near the unit.
• This unit is designed and tested to be a supplemental heater for use with a timer or a switch. It is not intended to be used as a primary source of heat, or controlled by a thermostat.
• To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc., off power unit.
• Provide a separate 20 AMP circuit.
• This product is designed for ceiling installation only. Do not mount this product in a wall.
• Install in ceiling only, at least 6 in. from any wall.
For greatest efciency, adjust heater grille directly toward tub or shower area. Avoid directing toward walls or windows.
Do not install less than 8 ft. (2.4 m) from the oor.
3
l
PREPARATION
Tools Required for Assembly (not included): Hammer, Flathead Screwdriver, Wire Nuts, Nails, Duct Tape, Phillips Head Screwdriver, Utility Knife Helpful Tools (not included): Electric Drill, Drill Bits
WARNING: Turn off electricity at breaker box before beginning installation.
• Carefully remove unit from carton.
• Before installation, provide inspection and future maintenance access at a location that will not interfere with installation work.
• Check area above installation location to be sure that wiring can run to the planned location and that duct work
can be run. Make sure the area is sufcient for proper ventilation.
• You may need the help of a second person to install this fan: one person on the attic side and one on the room side.
Note:
Installations may vary depending on how the previous bath fan was installed. Supplies necessary for the installation of your bath fan are not all included. However, most are available at your local home improvement or hardware store.
• Proper insulation around the fan to minimize building heat
loss and gain.
• Locate unit away from heating or cooling sources.
The fan will operate most efciently when located where the
shortest possible duct run and minimum number of elbows will be needed.
• Use a roof cap or wall cap that has a built-in damper to
reduce backdrafts.
• External timer/dimmer switch can be used please contact
Delta Breez customer service and consult with a licensed electrician for compatibility.
WARNING: Remove ceiling section using dimensions provided below. Be careful to cut hole exactly. If hole is too big, the fan grille will not hide it.
DIMENSION REQUIREMENTS
Housing
Dimension (L)
15 1/2 in. 9 1/2 in. 7 1/2 in.
Housing
Dimension (W)
Housing
Dimension (H)
4
Loading...