INSTALLATION AND OPERATING INSTRUCTIONS
VENTILATION FAN/LED LIGHT
READ AND SAVE THESE INSTRUCTIONS
GENERAL SAFETY INFORMATION
1. Make sure that the electric service supply
voltage is AC 120V, 60Hz.
2. Follow all local electrical and safety codes, as
well as the National Electrical Code (NEC) and
the Occupational Safety and Health Act (OSH
Act).
3. Always disconnect the power source before
working on or near the ventilating fan, motor
or junction box.
4. Protect the power cord from sharp edges, oil,
grease, hot surfaces, chemicals or other
objects.
5. Do not kink
the power cord.
6. Do not install the unit where ducts are
congured as shown in Fig. A.
7. Provide suction parts with proper ventilation.
8. This unit is UL listed for use over a bathtub or
shower when installed in a GFCI protected
branch circuit.
9. These ventilating fans are intended for
residential usage only.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by
the manufacturer. If you have questions,
act the manufacturer.
cont
2. Before servicing or cleaning unit, switch power
o at service panel and lock the service
disconnecting means to prevent power from
being switched on accidentally. When the
service disconnecting means cannot be locked,
securely fasten a prominent warning device,
such as a tag, to the service panel.
3. Installation work and electrical wiring must be
done by qualied person(s) in accordance with
all applicable codes and standards, including
re-rat
ed construction.
4. Sucient air is needed for proper combustion
and exhausting of gases through the ue
(chimney) of fuel burning equipment to
prevent back drafting. Follow the heating
equipment manufacturer’s guideline and
safety standards such as those published by
the National Fire Protection Association (NFPA),
and the American Society for Heating,
Refrigeration and Air Conditioning Engineers
(ASHRAE) and the local code authorities.
5. When cutting or drilling
not damage electrical wiring and other hidden
utilities.
6. Ducted fans must always be vented to the
outdoors.
7. If this unit is to be installed over a tub or
shower, it must be marked as appropriate for
the application and be connected to a GFCI
(Ground Fault Circuit Interrupter) – protected
branch circuit.
into wall or ceiling, do
8. Do not use this unit with any other solid-state
control devices. Solid-state control devices
may cause harmonic distortion, which can
cause
a motor humming noise.
9. NEVER place a switch where it can be reached
from a tub or shower.
10. Not to be installed in a ceiling thermally
insulated to a value greater than R40. (This is
required for installation in Canada only).
Tur ning a ngle too lar ge Duc t shri nk
Too m any e lbows Elbow near the b ody
Body
CAUTION
Fig. A
1. For general ventilating use only. Do not use to
exhaust hazardous or explosive materials and
vapors.
2. Not for use in cooking areas. (Fig. B)
3. This product must properly connect to the
grounding conductor of the supply circuit.
4. To reduce the risk of injury to persons, install
the fan at least 7 feet (2.1m) above the oor.
Coo king are a
Do not ins tall abo ve or
in side thi s are a
4
5
4
Co oking
Equ ipm ent
Fig. B
5
floo r
SUPPLIED ACCESSORIES
Part name Appearance Quantity
Grille
Fan 1
Housing 1
Duct
Connector
(4”)
MODEL GBR80LED
Page 1.
Screw
(ø4×25)
1. INSTALLATIONS
MOUNT HOUSING WITH FLANGE:
1-1. To bend the housing tabs out to 90 degrees
and make housing tabs contact the bottom of
the joist.
Tabs
1-2.
The housing mounts with 4 screws (ø 4×25). Screw
housing to joist through lowest holes in each
mounting ange, then through the other holes.
Screw ø 4×25
USING SUSPENSION BRACKETS (SOLD SEPARATELY)
1-3. Sliding suspension brackets available to allow
for your specic positioning of housing
anywhere between joists and span up to 24”.
1-4. Insert suspension brackets into the channels
on housing. Make sure tabs face “up” shown.
Suspension Bracket
(Sold separately)
Channel
1
1-5. Extend suspension brackets to the width of the
joists. Hold fan in place with the suspension
brackets tabs wrapping around the bottom of
joist.
1-6. Fasten suspension brackets to joists with nails
or screws through holes near nails.
1-7. Secure suspension brackets together with
screws.
Screw
Joist
Joist
1
Bottom of joist
4
Joist
Joist
Tab Face

GlobalTowne ~ 888-726-9752
MODEL GBR80LED
Page 2.
2. DUCT CONNECTION
2-1. Insert the duct (not provided) into the duct
connector and tape all ductworks connection
to make them secure and air tight.
2-2. Install the duct with a gradient 1°~2° to the
outside.
Outs ide
Duct Connecto r
Body
Ceiling
Tape
Grille
3. CONNECT WIRING
3-1. Follow all local electrical and ANSI/NFPA70.
3-2. NEVER place a switch where it can be reached
from a tub or shower.
LIGHT
SWITCH
FAN
SWITCH
BLK
LINE
WHT
IN
GRD
HOUSE ELECTRICAL BOX
3-3. Connect wires as shown in wiring diagrams.
3-4. Use wire nuts (not provided) and connect
house power cable to ventilating fan.
3-5. 14 AWG (2.1 mm
2
) is the smallest conductor
that shall be used for branch-circuit wiring.
4. TEST RUN & GRILLE ATTACHMENT
4-1. Insert the LED lighting connecting into the
power socket of main body as below shown.
4-2. When the power on, check for abnormal
vibration or sound.
4-3. Insert the mounting springs into the slots and
mount the grille to the fan unit
Lighting Connector
Slots
Grille
5. OPERATION
5-1. Turn on the power switch to operate ON or OFF,
and LED indicator is green.
Insid e
Duct
Gradient
1°~2°
LIGHT
(BLUE)
FAN
(BLK)
WHT
WHT
BLU
BLK
LIGHT/FAN ELECTRICAL BOX
.
Spring
6. MAINTENANCE
WARNING:
Disconnect power source before working on unit.
Routine maintenance must be done every year.
CAUTION:
1. Never use gasoline, benzene, thinner or any
other such chemicals for cleaning the
ventilating fan.
2. Do not allow water to enter motor.
3. Do not soak resin parts in water over 60°C.
CLEANING:
1. Pull down the spring to remove grille.
Use n
2. Clean grille. (
on-abrasive kitchen
detergent, wipe dry with new cloth.)
3. Use a cloth dampened with non-abrasive
kitchen detergent, remove dust and dirt from
ventilating fan. Wipe dry with new cloth.
4. Replace grille.
DIMENSIONS
"
8
5
2
.
8
10.75"
"
5.7 5 "
10.75"
4" DUCT
"
5
7
.
0
1
0.84"
SPECIFICATIONS-FAN
Model No.
Voltage
(V)
Frequen
cy
(Hz)
Power
@ 0.1SP
(W)
Air Flow
@ 0.1SP
(CFM)
GBR80LED 120 60 11.6 80 6.1 10.0
Note: Design and specications subject to change
without notice.
SPECIFICATIONS-LED LIGHT ENGINE
ITEM
DIMENSION(INCH)
POWER CONSUMPTION(W)
CORRELATED COLOR
TEMPERATURE (K)
SPEC.
8L×4.4W×1.4H
11
2700
LIGHT SOURCE LIFE(HOURS) 30000(MIN.)
TRANSIENT PROTECTION
OPERATING FREQUENCY(HZ)
FCC QUALIFIED
ENERGY QUALIFIED
ROHS QUALIFIED
CLASS A
120
YES
YES
YES
SAFETY REQUIREMENTS UL/cUL
5.75"
Weigh
1
t
(lb.)
0
.
7
5
"
8.25"
Power
@
0.0SP
(W)
WARRANTY
DELTA ELECTRONICS THREE YEAR LIMITED
WARRANTY
Delta Electronics Inc. (“Delta Electronics”)
warrants to the original consumer purchaser in
the USA that the Breez ventilation fan products
will be free from defects in material or
workmanship. This warranty is limited to three (3)
years from the original date of purchase.
Limitations and Exclusions
1. During the warranty period, a replacement for
any defective product will be supplied free of
charge for installation by the consumer. The
warranty provided herein does not cover
charges for labor or other costs incurred in the
troubleshooting, repair, removal, and
installation service.
2. All returns of defective parts or products must
include the product model number, and must
be made through an authorized Delta
Electronics distributor. Authorized returns must
be shipped prepaid. Repaired or replacement
products will be shipped by Delta Electronics
F.O.B. shipping point.
3. Delta Electronics shall not be liable for any
indirect, incidental, consequential, punitive, or
special damages arising out of or in connection
with products use or performance, regardless
of the form of action whether in contract, tort
(including negligence), strict product liability or
otherwise.
4. This warranty does not extend to uorescent
lamp starters and tubes.
5. The warranty does not cover if user does not
comply with manufacture’s installation manual.
6. To qualify for warranty service, you must notify
Delta Electronics at the address or telephone
number below.
7. Delta Electronics shall have no liability to the
original owner-user with respect to any defect
caused by abuse, misuse, neglect, improper
transportation or storage, improper testing,
improper installation, improper operation,
improper use, improper maintenance,
improper repair, improper alteration, improper
modication, tampering or accident of
products or parts thereof, or unusual
deterioration or degradation of products or
parts thereof due to a physical environment
beyond the requirements of products’
specications.