INSTALLATION AND OPERATING INSTRUCTIONS
VENTILATION FAN/LED LIGHT
READ AND SAVE THESE INSTRUCTIONS
GENERAL SAFETY INFORMATION
1. Make sure that the electric service supply voltage is AC 120V, 60Hz.
2. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupational Safety and Health Act (OSH Act).
3. Always disconnect the power source before working on or near the ventilating fan, motor or junction box.
4. Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals or other objects.
5. Do not kink
the power cord.
6. Do not install the unit where ducts are congured as shown in Fig. A.
7. Provide suction parts with proper ventilation.
8. This unit is UL listed for use over a bathtub or shower when installed in a GFCI protected branch circuit.
9. These ventilating fans are intended for residential usage only.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions,
act the manufacturer.
cont
2. Before servicing or cleaning unit, switch power o at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by qualied person(s) in accordance with all applicable codes and standards, including
re-rat
ed construction.
4. Sucient air is needed for proper combustion and exhausting of gases through the ue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
5. When cutting or drilling not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) – protected branch circuit.
into wall or ceiling, do
8. Do not use this unit with any other solid-state control devices. Solid-state control devices may cause harmonic distortion, which can cause
a motor humming noise.
9. NEVER place a switch where it can be reached from a tub or shower.
10. Not to be installed in a ceiling thermally insulated to a value greater than R40. (This is required for installation in Canada only).
Tur ning a ngle too lar ge Duc t shri nk
Too m any e lbows Elbow near the b ody
Body
CAUTION
Fig. A
1. For general ventilating use only. Do not use to
exhaust hazardous or explosive materials and vapors.
2. Not for use in cooking areas. (Fig. B)
3. This product must properly connect to the
grounding conductor of the supply circuit.
4. To reduce the risk of injury to persons, install
the fan at least 7 feet (2.1m) above the oor.
Coo king are a
Do not ins tall abo ve or
in side thi s are a
4
5
4
Co oking Equ ipm ent
Fig. B
5
floo r
SUPPLIED ACCESSORIES
Part name Appearance Quantity
Grille
Fan 1
Housing 1
Duct
Connector
(4”)
MODEL GBR80LED
Page 1.
Screw
(ø4×25)
1. INSTALLATIONS
MOUNT HOUSING WITH FLANGE:
1-1. To bend the housing tabs out to 90 degrees
and make housing tabs contact the bottom of the joist.
Tabs
1-2.
The housing mounts with 4 screws (ø 4×25). Screw housing to joist through lowest holes in each mounting ange, then through the other holes.
Screw ø 4×25
USING SUSPENSION BRACKETS (SOLD SEPARATELY)
1-3. Sliding suspension brackets available to allow
for your specic positioning of housing anywhere between joists and span up to 24”.
1-4. Insert suspension brackets into the channels
on housing. Make sure tabs face “up” shown.
Suspension Bracket (Sold separately)
Channel
1
1-5. Extend suspension brackets to the width of the
joists. Hold fan in place with the suspension brackets tabs wrapping around the bottom of joist.
1-6. Fasten suspension brackets to joists with nails
or screws through holes near nails.
1-7. Secure suspension brackets together with
screws.
Screw
Joist
Joist
1
Bottom of joist
4
Joist
Joist
Tab Face
GlobalTowne ~ 888-726-9752
www.globaltowne.com
MODEL GBR80LED
Page 2.
2. DUCT CONNECTION
2-1. Insert the duct (not provided) into the duct
connector and tape all ductworks connection to make them secure and air tight.
2-2. Install the duct with a gradient 1°~2° to the
outside.
Outs ide
Duct Connecto r
Body
Ceiling
Tape
Grille
3. CONNECT WIRING
3-1. Follow all local electrical and ANSI/NFPA70.
3-2. NEVER place a switch where it can be reached
from a tub or shower.
LIGHT SWITCH
FAN SWITCH
BLK
LINE
WHT
IN
GRD
HOUSE ELECTRICAL BOX
3-3. Connect wires as shown in wiring diagrams.
3-4. Use wire nuts (not provided) and connect
house power cable to ventilating fan.
3-5. 14 AWG (2.1 mm
2
) is the smallest conductor
that shall be used for branch-circuit wiring.
4. TEST RUN & GRILLE ATTACHMENT
4-1. Insert the LED lighting connecting into the
power socket of main body as below shown.
4-2. When the power on, check for abnormal
vibration or sound.
4-3. Insert the mounting springs into the slots and
mount the grille to the fan unit
Lighting Connector
Slots
Grille
5. OPERATION
5-1. Turn on the power switch to operate ON or OFF,
and LED indicator is green.
Insid e
Duct
Gradient
1°~2°
LIGHT
(BLUE)
FAN
(BLK)
WHT
WHT
BLU
BLK
LIGHT/FAN ELECTRICAL BOX
.
Spring
6. MAINTENANCE
WARNING:
Disconnect power source before working on unit. Routine maintenance must be done every year.
CAUTION:
1. Never use gasoline, benzene, thinner or any other such chemicals for cleaning the ventilating fan.
2. Do not allow water to enter motor.
3. Do not soak resin parts in water over 60°C.
CLEANING
1. Pull down the spring to remove grille.
Use n
2. Clean grille. (
on-abrasive kitchen
detergent, wipe dry with new cloth.)
3. Use a cloth dampened with non-abrasive kitchen detergent, remove dust and dirt from ventilating fan. Wipe dry with new cloth.
4. Replace grille.
DIMENSIONS
"
8
5
2
.
8
10.75"
"
5.7 5 "
10.75" 4" DUCT
"
5
7
.
0
1
0.84"
SPECIFICATIONS-FAN
Model No.
Voltage
(V)
Frequen
cy
(Hz)
Power
@ 0.1SP
(W)
Air Flow @ 0.1SP
(CFM)
GBR80LED 120 60 11.6 80 6.1 10.0
Note: Design and specications subject to change without notice.
SPECIFICATIONS-LED LIGHT ENGINE
ITEM
DIMENSIONINCH
POWER CONSUMPTIONW
CORRELATED COLOR
TEMPERATURE (K)
SPEC.
8L×4.4W×1.4H
11
2700
LIGHT SOURCE LIFEHOURS 30000MIN.
TRANSIENT PROTECTION
OPERATING FREQUENCYHZ
FCC QUALIFIED
ENERGY QUALIFIED
ROHS QUALIFIED
CLASS A
120
YES
YES
YES
SAFETY REQUIREMENTS UL/cUL
5.75"
Weigh
1
t
(lb.)
0
.
7
5
"
8.25"
Power
@
0.0SP (W)
WARRANTY
DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY
Delta Electronics Inc. (“Delta Electronics”) warrants to the original consumer purchaser in the USA that the Breez ventilation fan products will be free from defects in material or workmanship. This warranty is limited to three (3) years from the original date of purchase.
Limitations and Exclusions
1. During the warranty period, a replacement for any defective product will be supplied free of charge for installation by the consumer. The warranty provided herein does not cover charges for labor or other costs incurred in the troubleshooting, repair, removal, and installation service.
2. All returns of defective parts or products must include the product model number, and must be made through an authorized Delta Electronics distributor. Authorized returns must be shipped prepaid. Repaired or replacement products will be shipped by Delta Electronics F.O.B. shipping point.
3. Delta Electronics shall not be liable for any indirect, incidental, consequential, punitive, or special damages arising out of or in connection with products use or performance, regardless of the form of action whether in contract, tort (including negligence), strict product liability or otherwise.
4. This warranty does not extend to uorescent lamp starters and tubes.
5. The warranty does not cover if user does not comply with manufacture’s installation manual.
6. To qualify for warranty service, you must notify Delta Electronics at the address or telephone number below.
7. Delta Electronics shall have no liability to the original owner-user with respect to any defect caused by abuse, misuse, neglect, improper transportation or storage, improper testing, improper installation, improper operation, improper use, improper maintenance, improper repair, improper alteration, improper modication, tampering or accident of products or parts thereof, or unusual deterioration or degradation of products or parts thereof due to a physical environment beyond the requirements of products’ specications.
Address:4405 Cushing Parkway, Fremont, CA 94538 US Toll Free Number: 1-888-979-9889
Loading...