Delta 827 W RF TYBOX Installation

• These instructions apply to both TYBOX 817 WRF and TYBOX 827 WRF.
• The hot water mode ( ) is only available on the TYBOX 827 WRF.
1. Installing the RF 817 or 827 receiver
TYBOX 817- 827 W RF
1 and 2-channel wireless programmers with built-in thermostat
Installation instructions
TYBOX 827 RF
Delta Dore hereby declares that the equipment complies
with the essential requirements and other relevant provisions
of the R&TTE Directive 1999/5/EC.
on request, from:
DELTA DORE - Bonnemain - 35270 Combourg (France)
“Technical info” department
Email: info.techniques@deltadore.com
• Carefully read these instructions prior to installation.
• The unit must be installed in compliance with current standards.
• Always switch off the mains before installing or servicing the unit.
• Do not attempt to repair the unit yourself; after-sales service is available.
• Check that the fastenings are suitable for the surface to which the unit will be mounted (plasterboard, brick, etc.).
• The diagrams provided are simplified for greater clarity. Protection and other accessories required by standards are not illustrated. Standards and good practice must be complied with. Connected or nearby units must not generate excessive interference 2004/108/EC)
.
(Directive
2. Connecting the RF 817 or RF 827 receiver
RF 817 RF 827
Example 1: 230V powered contact
NL
CH
NL1 23 4
230V~
50-60 Hz
OFF
3A max. / 230V~
CH ON
With a 3-port mid-position valve With 2 spring-return valves
NL
2
HW OFFCHOFFHWONCHON
NL12 34
230V~
50-60 Hz
Cons. 11 VA P = 1.2 W
3A max. (230V~)
1
2721320 Rev.1
GR O BL W
CYL. STAT
1C2
3
RF 817
NL1 23 4
230V~
50-60 Hz
Cons. 11 VA P = 1.2 W
OFF
3A max. / 230V~
RF 827
HW
Cons. 11 VA P = 1.2 W
boiler
OFFCHOFFHWONCHON
NL1 23 4
230V~
50-60 Hz
Pump or
CH
3A max. (230V~)
4
CH ON
2721319 Rev.1
6
5
2721320 Rev.1
NL
CYL. STAT
1C2
Pump or
boiler
Because of changes in standards and equipment, the characteristics given in the text and the illustrations in this document are not binding unless confirmed.
3. Installing the transmitter
A
~1.50 m
Mini 20 cm
B
A
1
Example 2: Volt free contact
NL
*2702542_rev.2*
B
1
2
CH
NL1 23 4
230V~
50-60 Hz
OFF
3A max. / 230V~
2
HW
CH
CH ON
NL1
230V~
50-60 Hz
OFF
HWONCH
OFF
2 3 4
3A max. (230V~)
ON
NL1 23 4
230V~
50-60 Hz
HW
OFF
CH
HWONCH
OFF
3A max. (230V~)
ON
4. Date / time
2
3
4
1
3
R: back to previous
3
4
5
setting
DD.MM.YY
PM
11.59 (23.59)
AM
12.00 (00.00)
5. Wireless association (prebound)
The transmitter and the receiver are already associated when delivered. You may however need to reassociate your products (after removing wireless associations for instance).
... ... ...
1
2
> 3 sec.
6 7 8 109
> 5 sec.
3 4 5
OK
4
6. Compatible home automation options
You can associate your programmer with the following options:
Type of transmitter associated
Opening detector
Wireless outdoor sensor
For information about associating and
using home automation products,
“Technical info” department
DELTA DORE - Bonnemain
35270 Combourg (France)
Email: info.techniques@deltadore.com
Resulting function
“Energy saving” function
Heating switches to Frost Protection mode when a window is opened (temperature set in mode).
Indication of outside temperature by consulting the information menu (
i button).
contact:
7. Basic configurations (menu 1)
1 2
Modification of programme
User modification authorisation
8. Advanced configurations (menu 2)
and temperature settings (from 5 °C to 30 °C) authorised (default)
Modification of programme not authorised and temperature settings restricted (19 °C +/- 3 °C)
> 5 sec.
Time display selection
Automatic summer/winter mode authorisation
3
12-hour clock (default)
24-hour clock
Not authorised
Authorised (by default)
0
1
12h
24h
0
1
HH:MM HH:MM
4 5 6 7 8
Setting from 12:00 to 00:00
ONCE programme start time
ONCE programme end time
+/-
0,1°C
(default value: 07:00AM)
Setting from 12 noon to 12 midnight (default value: 11:00PM)
365
001
5°C
30°C
9
2h
4h
0
1
1 2
Correction possible from -5 °C to
Correcting the temperature measured
Number of days before service
+5 °C in increments of 0.1 °C. Press the + or - buttons to modify and press the OK button to confirm.
Service Interval
Choice of 1 to 365 days or --- to desactivate the function (default value: 365)
9. Return to the factory configuration
1 2 3
3
> 5 sec.
Service Interval: display of the time remaining before mandatory service required. After this time, if the service has not been done, the operating temperature setting for heating is fixed (menu 2-03) and the DHW switches to OFF (unless overridden, menu 2-04).
Temperature applied after
Temperature selection Service Interval
Service Interval
Choice of 5 to 30 °C (default value: 16 °C)
> 5 sec. > 5 sec.
Press the button for the menu you wish to reset and hold for 5 seconds (example for menu 1).
4 5 6 7 8
DHW override after Service
Authorised DHW override time
Anti-seizing of circulator pump
Interval
2, 3 or 4 hours (default value: 2 hours).
Anti-seizing off (by default)
Anti-seizing enabled (circulator pump operates for 1 minute every 24 hours)
9
10. Deleting wireless associations
4
> 5 Sec. > 5 Sec.
1 2 3
4
11. Wireless test
2
> 5 sec.
1
The receiver LED should flash each time a signal is received (approximately every 5 seconds).
If this is the case, radio transmission is occurring properly.
Otherwise, move your transmitter.
To reconfigure the receiver with the transmitter, refer to the “Wireless association” section.
NOTE: You can manually reset the receiver by pressing the button of the channel to be initialised
5
for 10 seconds until the LED flashes rapidly.
12. Technical characteristics
... ... ...
3
... ... ...
4
Transmitter TYBOX 817- 827 RF
• Powered by two LR03/AAA 1.5 V alkaline batteries (supplied), battery life of 2 years for normal use
• Class III insulation
• Clock backup when replacing the batteries: 30 seconds
• Transmission frequency 868 MHz (Standard EN 300 220)
• Class 1 radio equipment (can be placed on the market and put into service without any restrictions)
• Wireless range: 100 to 300 metres outside, depending on the equipment associated (the range varies according to installation conditions and the electromagnetic environment)
• Wireless remote control device
• Dimensions: LxHxD = 80 x 103 x 16 mm
• Protection rating: IP 30
• Storage temperature: -10 °C to +70 °C
• Operating temperature: 0 °C to +40 °C
• Installation in an environment with normal pollution levels
• Attachment with screws or on a base
Receiver RF 827
• 230V, 50 Hz power supply, +/-10%,
• Consumption: 11 VA (P=1.2 W)
• Class II insulation
• Radio frequency 868 MHz (standard EN 300 220)
• Wireless range: 100 to 300 metres outside, variable depending on the associated equipment (the range can vary depending on the installation conditions and the electromagnetic environment)
• Automatic action: 1.C (micro-interruption)
• Storage temperature: -10 °C to +70 °C
• Operating temperature: 0 °C to +40 °C
• Installation in an environment with normal pollution levels
• Screw mounting (standard Wallplate)
• Contact output 3 A max., 230 V Cos ϕ= 1
• Dimensions: 96 x 96 x 39 mm
• Protection rating: IP 20
5
13. Troubleshooting
Nothing is displayed on the room unit screen.
There is no power supply.
Check the batteries.
The receiver does not accept orders from the transmitter.
• Check the transmission by performing a wireless test
• Move your transmitter if necessary
• Repeat the wireless association of the receiver with the TYBOX RF
The icon appears.
The batteries are low.
Change the batteries, ensuring they are in the correct position.
During radio association, the device displays: rAd 1.
This menu is reserved.
Associate the receiver again from the rAd menu.
The heating does not work according to the required temperature.
If you have a Room Thermostat wired in series with the programmer, check that this thermostat is set to maximum.
5