DeLonghi ELECTRIC SUPER PANEL HEATER, 500 W, 800 W Instruction Manual

Page 1
ELECTRIC SUPER PANEL HEATER
We were thinking of you
when we thought of it
Australia
P.O.Box 597 Riverwood NSW 2210 Customer Service Ph: 1800 126659 Fax: 1800 706932 e-mail:custserv@parex.co.nz
Made in PRC Proundly distributed by
Parex Industries Limited
25 CARBINE ROAD, MT WELLINGTON PO BOX 58056
GREENMOUNT Auckland, New Zealand Customer Service Ph: (09) 915 7273 Fax: (09) 915 7280 e-mail:custserv@parex.co.nz
Page 2
2
C
A
(X)
50 mm min
25 mm min
25 mm min
BB
F
F
E
F
F
Bracket
Bracket
Screw
Screw
Wall plug
50 mm min
D
Electric Super Panel Heater
Description of heater
The following terms are used throughout the instruction manual
Model 500 W 800 W
A
464 714
B
149 149
C
65 65
D
497 497
E
425 675
All measurements are in mm
Fig.1
Page 3
3
1
2
(Y)
Fig.2
Fig.3
HOW TO USE YOUR ELECTRIC SUPER PANEL HEATER
Thank you for choosing this Dè Longhi heater. Please read this instruction booklet carefully before using this heater. By doing so, you will obtain optimum results with maximum safety.
General instructions
Remove the heater from the packaging. Check that neither the heater nor the power cable has been damaged during transport. Do not operate the heater if damaged.Your heater is suitable for either freestanding or wall mounting usage. Do not assemble the feet if wall mounting.
Free standing operation
To fit the feet to the appliance, proceed as follows: Slide the foot’s tab on the slot provided on the back of the heater then fix the foot with the relevant screw, as shown in fig.2.
Installation wall-mounting
The wall mounting kit should contain: 2 x Upper brackets (X) 2 x Lower brackets (Y) 4 x Screws (4,5 x 25) 4 x Wall plugs ( ø 6 x 30) 2 x Feet screws (3,5 x 9,5) (for freestanding operation)
1. Select position for siting the heater ensuring that:
a. It is not located directly below a power socket outlet. b.The plug and power outlet can be easily reached after
installation. c. No electric cables or other tubes could be damaged. d.Keep away from curtains or inflammable materials.
Also note the minimum distances indicated in the
description:
2. Before drilling the wall, mark out a template following carefully the dimensions as shown in fig.1.
3. For solid brick walls, use a 6mm masonry drill bit and drill according to the marks F you have made and then insert the wall plugs provided. (For plasterboard we suggest, locating the stud­ding and using No. 6 woodscrews directly into the wood,or spe­cial plasterboard fixings. For other wall types please seek special­ist advice).”
4. Mount the wall bracket “X” in the “F” holes using the screws provided.
5. Hang the heater on the brackets.
6. Position the lower brackets (Y) into the tabs located in the base of the heater. See Fig 3. Move the bracket up until it is horizon­tal and then fix them with the screws provided.
Electric Super Panel Heater
Page 4
4
INSTRUCTIONS FOR USE Switching on
Plug into the mains socket. Switch the appliance on using the
switch/switches following the procedures given:
-switch «Eco» = minimum power (indicator light on);
-switch «Med» = intermediate power (indicator light on);
- both switchess «Eco» «Med» = Max (indicator lights on)
To turn appliance off, switch off both switches or remove plug from wall socket.
Maintenance
Before carrying out any maintenance, unplug the heater from the mains and wait for it to cool.The heater requires no particular maintenance. It is sufficient to remove the dust with a soft, dry cloth. Never use abrasive powders or solvents. If necessary remove concentrated areas of dirt with a vacuum cleaner.
Warnings
- Do not use the heater in a bathroom or in the vicinity of bath­tubs, washbasins, showers or swimming pools.
-Never use the heater to dry laundry.
-Never place the power cable on top of the heater while it is hot.
- Only use the heater in an upright position.
- The appliance is not intended for use by young children or infirm persons without supervision.
-Youg children should be supervised to ensure that they do not play with the appliance.
- If the supply cord is damaged, it must be replace by the manu­facturer or its service agent or a similarly qualified person in order to avoid a hazard.
- Do not locate the heater immediately below a socket- outlet.
-Do not block the hot-air outlet grilles or the intake grille.
- If the power cable is damaged, it must be replaced by the manu­facturer or an authorised technical service centre. We recommend that you not place the heater in a draught, because strong draughts of air may adversely affect the equip­ment’s operational efficiency.
- IMPORTANT: Never for any reason cover the appliance dur- ing operation as this could lead to dangerous overheating.
- The use of an extension lead is not recommended, as overheating of the extension lead may occur during the operation of the heater.
- This appliance is filled with a precise quantity of oil and repairs which require it to be opened must be carried out exclusively by the manufacturer or an authorised service centre. In the case of oil leaks, contact the manufacturer or the authorised service centre.
Electric Super Panel Heater
Page 5
- When scrapping the appliance,respect legislation on the disposal of oil.
- As with any electrical appliance, whilst the instructions aim to cover as many eventualities as possible, caution and common sense should be applied when operating your appliance, particu­larly in the vicinity of young children.
-Position the appliance so that the plug and the outlet can be easily reached even after installation.
ELECTRICAL CONNECTION
- Before plugging the appliance into the mains, check that your supply voltage is the same as that shown on the rating plate of the appliance and that the electric installation is suitable to the power shown on the rating plate.
Electric Super Panel Heater
5
Page 6
5712000200/12.02