Dell Z9500 Installation Manual

Dell Networking Installation Guide for the Z9500 Switch
Notes, Cautions, and Warnings
NOTE: A NOTE indicates important information that helps you make better use of your computer.
CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
Copyright © 2014 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and
intellectual property laws. Dell™ and the Dell logo are trademarks of Dell Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies.
2014–07
Rev. A02
Contents
1 About this Guide....................................................................................................5
Related Publications..............................................................................................................................5
2 Introduction...........................................................................................................6
Product Description.............................................................................................................................. 6
3 Unpacking the Switch.......................................................................................... 7
Hardware Installation Overview............................................................................................................7
4 Hardware Overview..............................................................................................9
I/O Panel................................................................................................................................................9
Utility Panel..........................................................................................................................................10
Power Supplies.............................................................................................................................. 10
Fans................................................................................................................................................ 10
System Status.......................................................................................................................................10
5 Site Preparation...................................................................................................14
Site Selection....................................................................................................................................... 14
Cabinet Placement..............................................................................................................................14
Storing Components........................................................................................................................... 15
6 Z9500 Installation...............................................................................................16
Assemble 4–Post Rack Frame............................................................................................................ 16
Attaching the Mounting Brackets....................................................................................................... 16
Attaching the Static-Rails Mounting Brackets..............................................................................16
Installing the Dell Static Rails System..................................................................................................17
Identifying the Rail Kit ContentsInstalling and Removing Tool-less Rails (Square-
Hole)Installing and Removing Tooled Rails (Threaded-Hole Racks or Round-Hole Racks)...... 17
Mounting the Chassis in a Four-Post Rack........................................................................................20
Securing the Chassis Ground............................................................................................................. 24
Installing Fan Modules.........................................................................................................................25
Installing AC Power Supplies.............................................................................................................. 26
Securing Power Cables.......................................................................................................................28
Installing the Cable Management System (OPTIONAL).................................................................... 29
Installing the Cable Management System for Direct Attach Copper (DAC) Cables...................29
Installing the Cable Management System for Optical Fibres.......................................................31
Installing the QSFP+ Optics................................................................................................................32
Port Numbering Convention.............................................................................................................. 33
Splitting QSFP+ Ports to SFP+ Ports.................................................................................................. 33
Important Points to Remember....................................................................................................34
Supplying Power and Powering Up the System................................................................................ 34
AC Power.......................................................................................................................................34
7 Technical Specifications....................................................................................35
8 Agency Compliance........................................................................................... 36
USA Federal Communications Commission (FCC) Statement......................................................... 36
Canadian Department of Communication Statement...................................................................... 36
European Union EMC Directive Conformance Statement............................................................... 36
European Community Contact.....................................................................................................37
Japan: VCCI Compliance for Class A Equipment.............................................................................. 37
Korean Certification of Compliance.................................................................................................. 38
Safety Standards and Compliance Agency Certifications................................................................. 38
Electromagnetic Compatibility (EMC)................................................................................................38
Product Recycling and Disposal.........................................................................................................39
9 Technical Support..............................................................................................40
The iSupport Website......................................................................................................................... 40
Accessing iSupport Services...............................................................................................................40
Requesting a Hardware Replacement............................................................................................... 40
Contacting Technical Support............................................................................................................41
1

About this Guide

This guide provides site preparation recommendations, and step-by-step procedures for rack mounting, installing modules, and connecting to a power source.
After you have completed the hardware installation and power-up of the Z9500, for software configuration information, refer to the Dell Networking Configuration Guide for the Z9500 Switch and for Command Line Interface (CLI) information, refer to the Dell Networking Command Line Reference Guide
for the Z9500 Switch.
CAUTION: To avoid electrostatic discharge (ESD) damage, wear grounding wrist straps when handling this equipment.
WARNING: Only trained and qualified personnel can install this equipment. Read this guide before you install and power up this equipment. This equipment contains two power cords. Disconnect both power cords before servicing.
WARNING: This equipment contains optical transceivers, which comply with the limits of Class 1 laser radiation.
WARNING: When no cable is connected, visible and invisible laser radiation may be emitted from the aperture of the optical transceiver ports. Avoid exposure to laser radiation and do not stare into open apertures.

Related Publications

For more information about the Z9500, refer to the following documents:
Dell Networking Configuration Guide for the Z9500 Switch
Dell Networking Command Line Reference Guide for the Z9500 Switch
Dell Networking Release Notes for the Z9500 Switch
NOTE: For the most recent documentation and software, visit iSupport (registration for access to some sections is required): http://www.dell.com/support/manuals.
About this Guide
5
2

Introduction

This document provides basic information about installing the Z9500 switch. For information about how to configure and monitor switch features, refer to the Dell Networking
Configuration Guide for the Z9500 Switch, which is available on the Dell Support website at http://
support.dell.com/manuals.
This document contains the following sections:
Product Description
Unpacking the Switch
Hardware Overview
Site Preparations
Z9500 Installation
Technical Specifications
Agency Compliance
Technical Support

Product Description

The Z9500 is part of Dell Networking's Z-Series family of Data Center Core switches. The Z9500 switch is a compact 3 RU (Rack Unit), high-performance, and low-latency 10/40–Gigabit
Ethernet switch. It runs the Dell Networking Operating Software (OS) , providing features and capabilities that are widely deployed.
The Z9500 switch has the following features:
132 fixed Quad Small Form-Factor Pluggable (QSFP+) ports on the I/O side of the switch.
Four slots on the Utility side of the switch for hot swappable power supplies.
Five slots on the Utility side of the switch for hot swappable fan modules.
A management and console interface on the I/O side of the switch.
6
Introduction
3

Unpacking the Switch

The switch and its accessories are shipped in a single box. The power cords may be shipped in a separate box. Before unpacking the switch, inspect the container and immediately report any evidence of damage. Verify that you have received your ordered items, including the following:
WARNING: If any item is missing or damaged, contact your Dell Networking representative or reseller for instructions.
CAUTION: Always wear an ESD-preventive wrist or heel ground strap when handling the switch and its components. Ground yourself by using an antistatic wrist strap or other device and connect it to the ESD grounding jack on the chassis. As with all electrical devices of this type, take all necessary safety precautions to prevent injury when installing this system.
CAUTION: The system is packaged in one or two separate containers. Use an equipment lift or pallet jack to lift or install the chassis. Lifting the system by its shelves will cause damage to the chassis
Z9500 switch
Static-Rail kit (#1 and #2 Phillips and flat-tipped screwdrivers required)
NOTE: One Rail Kit is required for every chassis in a rack.
Screws for rack installation
Console cables
Any optional items ordered
Getting Started Guide
Safety and Regulatory Information
Warranty and Support Information
Software License Agreement
1. Place the container on a clean, flat surface and cut all straps securing the container.
2. Open the container or remove the container top.
3. Carefully remove all components from the container and place it on a secure and clean surface.
4. Remove all packing material.
5. Inspect the switch and accessories for damage.

Hardware Installation Overview

To install the Z9500, follow these steps:
1. Assemble 4-Post Rack Frame
2. Attaching the Mounting Brackets
3. Installing the Dell Static Rails System
4. Securing the Chassis Ground
5. Installing AC Power Supplies
Unpacking the Switch
7
6. Installing Fan Modules
7. Securing Power Cables
8. Installing the QSFP+ Optics
9. Installing the Cable Management System
10. Supplying Power and Powering Up the System
8
Unpacking the Switch
4

Hardware Overview

This section contains information about device characteristics and modular hardware configurations for the Z9500. The Z9500 has the following physical dimensions:
Height: 5.2 inches (132.08 mm)
Width: 17.4 inches (441.96 mm)
Depth: 32 inches (812.80 mm)
The Z9500 has a chassis design with 5280Gbps switching bandwidth. The system also provides one DB9 RS-232 console port with YOST RJ-45 pinout and a dedicated Ethernet service port for out-of-band (OOB) management functions.

I/O Panel

All fixed data ports (132 × 40GbE quad small form-factor pluggable plus [QSFP+] ports) are on the I/O panel.
Figure 1. I/O Panel
The I/O panel includes:
132 fixed Quad Small Form-Factor Pluggable (QSFP+) ports
Light Emitting Diodes (LEDs)
Management ports
NOTE: The LED displays for the system status are on the I/O side of the chassis. The fan and power status LEDs are on the Utility panel.
Hardware Overview
9

Utility Panel

The Utility panel side of the platform contains the fan and power modules.
Figure 2. Utility Side
1. Fan Trays 2. Power Supplies

Power Supplies

The Z9500 supports four hot-swappable Power supply units (PSUs) .
NOTE: The PSUs must be installed at the customer site.
PSUs are field replaceable. To ensure power redundancy and adequate cooling, install four power supplies in the switch. When running with full redundancy (four PSUs installed and running), you can remove and replace a PSU while the other PSUs are running without disrupting traffic.

Fans

The Z9500 supports five fan trays with airflow directions from I/O to Utility.
The fans must be installed at the customer site.

System Status

You can view Z9500 status information in several ways, including:
LEDs
CLI show commands
Simple network management protocol (SNMP)
For more information about these options, refer to the Dell Networking Command Line Reference Guide and Dell Networking Configuration Guide for the Z9500 Switch.
As shown in the following figure, the Z9500 includes LED displays on the I/O and Utility side of the chassis. When the Z9500 powers up or reloads, the status LED on the power supplies are solid green.
10
Hardware Overview
The following table lists the LED definitions for the Z9500 system.
Figure 3. System LED Displays (I/O Panel)
1. Alarm LED 2. System status LED
3. System locator LED 4. 10GbE channel selection indicator
5. 10GbE channel selector button 6. Management Port Activity LED
7. Management Port Status LED
Table 1. System LED Displays (I/O Panel)
Label LED Color/
Display
Off
Alarm LED
Amber solid
Red solid
Off
System status LED
Green solid
Green blinking
Off
System locator LED
Management port activity LED
Blue solid
Off
Green blinking
Hardware Overview
Description
No alarm
Minor alarm
Major alarm
No power
Normal operation
System is booting
No activity
Port locator
No activity
The port and the link are active, and there is link activity
11
Label LED Color/
Description
Display
Management port status LED
Figure 4. 40GbE Port LEDs (I/O Panel)
Off
Green solid
Port is Down
Traffic on Management Port
1. Port LED
NOTE: In 40GbE mode, the front end ports are “solid green” color in operational state. However, if the port is configured to work in 10GbE mode, then the front end ports are “solid amber” color in operational state.
NOTE: The four 10GbE ports split from a single 40GbE port share the same locator LED as the 40GbE port. Use the CLI system location-led interface fortyGigE /tengigabitethernet SLOT/PORT on command to locate the 10GbE/40GbE port and then press the channel selector button to locate the corresponding 10GbE port as shown in Figure 3. When port locator functionality is enabled on a port - the corresponding port LED turns solid blue.
Table 2. 40GbE Port LEDs
Label LED Color/Display Description
Port locator LED
Port link/activity LED
Off
Blue
Off
Green solid
Green blinking
Amber solid
Amber blinking
No activity
Port locator
No link or interface disabled
40GbE link present and interface enabled
Port has activity
10GbE link present and interface enabled
10GbE port has activity
12
Hardware Overview
Figure 5. System LED Displays (Utility Panel)
1. Fan status LED 2. PSU status LED
Table 3. System LED Displays (Utility Panel)
Label LED Color/Display Description
PSU status LED
Green solid
Amber Solid
Off
Normal operation
Minor/Major alarms
Power not present
Fan status LED
Green solid
Amber Solid
Off
Normal operation
Minor/Major alarms
Power not present
Hardware Overview