ConnectX®-3 Dual Port 40Gb/s and 56Gb/s
Mezzanine Card for Dell User Manual
0J05YT, 0K6V3V
Rev 1.0
www.mellanox.com
Page 2
NOTE:
THIS HARDWARE, SOFTWARE OR TEST SUITE PRODUCT (“PRODUCT(S)”) AND ITS RELATED DOCUMENTATION ARE PROVIDED BY MELLANOX TECHNOLOGIES “AS-IS” WITH ALL FAULTS OF ANY KIND AND SOLELY FOR THE PURPOSE OF
AIDING THE CUSTOMER IN TESTING APPLICATIONS THAT USE THE PRODUCTS IN DESIGNATED SOLUTIONS. THE CUS
TOMER'S MANUFACTURING TEST ENVIRONMENT HAS NOT MET THE STANDARDS SET BY MELLANOX TECHNOLOGIES
TO FULLY QUALIFY THE PRODUCTO(S) AND/OR THE SYSTEM USING IT. THEREFORE, MELLANOX TECHNOLOGIES CAN
NOT AND DOES NOT GUARANTEE OR WARRANT THAT THE PRODUCTS WILL OPERATE WITH THE HIGHEST QUALITY.
ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MER
CHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT ARE DISCLAIMED. IN NO EVENT
SHALL MELLANOX BE LIABLE TO CUSTOMER OR ANY THIRD PARTIES FOR ANY DIRECT, INDIRECT, SPECIAL, EXEM
PLARY, OR CONSEQUENTIAL DAMAGES OF ANY KIND (INCLUDING, BUT NOT LIMITED TO, PAYMENT FOR PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
(INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY FROM THE USE OF THE PRODUCT(S) AND RELATED
DOCUMENTATION EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
-
-
-
-
Mellanox Technologies
350 Oakmead Parkway Suite 100
Sunnyvale, CA 94085
U.S.A.
www.mellanox.com
Tel: (408) 970-3400
Mellanox Technologies, Ltd.
PO Box 586 Hermon Building
Yokneam 20692
Israel
Tel: +972-4-909-7200
Fax: +972-4-959-3245
This document was first printed on February 14, 2012
Table 1 - Revision History Table
DateRevComments/Changes
February
2012
1.0Initial Release
.
6
Mellanox Technologies
Page 7
ConnectX®-3 Dual Port 40Gb/s and 56Gb/s Mezzanine Card for Dell User ManualRev 1.0
About this Manual
This User Manual describes ConnectX®-3 Dual QSFP Port mezzanine card for the Dell Blade
Servers. It provides details as to the interfaces of the board, specifications, required software and
firmware for operating the cards, installation instructions, and relevant documentation.
Intended Audience
This manual is intended for the installer and user of the mezzanine cards.
®
The manual assumes basic familiarity with the InfiniBand
tions.
PCI Express 3.0 SpecificationsIndustry Standard PCI Express 3.0 Base and Card Electromechanical
Documents List
Online Resources
• Mellanox Technologies Web pages: http://www.mellanox.com
• Dell Support Web pages: http://support.dell.com
Document Conventions
When discussing memory sizes, MB and MBytes are used in this document to mean size in mega
bytes. The use of Mb or Mbits (small b) indicates size in mega bits.
Specifications
These symbols indicate a situation, status, or condition that may cause harm
to people or damage to the equipment.
Mellanox Technologies
7
Page 8
Rev 1.0
8
Mellanox Technologies
Page 9
ConnectX®-3 Dual Port 40Gb/s and 56Gb/s Mezzanine Card for Dell User ManualRev 1.0
1 Overview
This document is a User Manual for the Mellanox Technologies ConnectX®-3 40Gb/s and 56Gb/
s InfiniBand dual-port mezzanine cards for the Dell Blade Servers. The cards described in this
manual have the following main features:
1.2Finding the GUID/MAC and Serial Number on the Mezzanine Cards
All cards include a label that has the card serial number and the card GUID for InfiniBand protocol
on the print side of the card.
Mellanox Technologies
9
Page 10
Figure 1: 0J05YT Label
Figure 2: Board Label
OverviewRev 1.0
Figure 3: 0K6V3V Label
Figure 4: Board Label
10
Mellanox Technologies
Page 11
ConnectX®-3 Dual Port 40Gb/s and 56Gb/s Mezzanine Card for Dell User ManualRev 1.0
2Card Interfaces
2.1I/O Interfaces
Each mezzanine card includes the following interfaces:
• PCI Express (PCIe)
•I2C-compatible connector (for debug)
Figure 5: 0J05YT/0K6V3V Card
2.1.1 InfiniBand Interface
The ConnectX®-3 mezzanine cards are compliant with the InfiniBand Architecture Specification,
Release 1.2.1. It has two compliant InfiniBand ports with four Tx/Rx pairs of SerDes.
Mellanox Technologies
11
Page 12
2.1.2 PCI Express Interface
The ConnectX®-3 mezzanine cards support PCI Express 3.0 (1.1 and 2.0 compatible) . The device
can be either a master initiating the PCI Express bus operations or a slave responding to PCI bus
operations.
2.1.3 I2C-compatible Interface
A three-pin header on the mezzanine cards is provided as the I2C-compatible interface.
Card InterfacesRev 1.0
Figure 6: I2C Connector
2.2Power
All adapter cards receive 12V and 3.3V power from the PCI Express connector. All other required
power voltages are generated by on-board switch mode regulators. See
Appendix A.2,“Specifications,” on page 30.
2.3Memory
The mezzanine cards support multiple memory devices through the PCI Express, SPI (Flash), and
2
I
C-compatible interfaces.
2.3.1 System Memory
The mezzanine cards utilize the PCI Express interface to store and access fabric connection information on the system memory.
2.3.2 SPI
The mezzanine cards include one SPI Flash device accessible via the Flash interface of the ConnectX®-3 device.
12
Mellanox Technologies
Page 13
ConnectX®-3 Dual Port 40Gb/s and 56Gb/s Mezzanine Card for Dell User ManualRev 1.0
A jumper inserted into the drill on each adapter card indicates to the device whether an on-board
Flash device is to be used or not. Table 4 provides information on this jumper.
Table 4 - Jumper Configuration
DescriptionOption
Flash present/
not present
2.3.3 EEPROM
The mezzanine cards incorporate an EEPROM that is accessible through the I2C-compatible interface. The EEPROM capacity is 4Kb. The EEPROM is used for storing the Vital Product Data
(VPD) and FRU.
plies with the format defined in the PCI 3.0 Specification,
Card Default
Configuration
connection open – Flash present
connection shorted – Flash not present
connection open –
Flash present
The PCI VPD (Vital Product Data) layout for each of the mezzanine cards com-
Appendix I.
Table 5 - 0J05YT VPD Layout
Offset
(Decimal)
0Large Resource Type ID
1Length [7:0] LSB0x14
2Length [15:8] MSB0x0
3DataDELL ConnectX-3
23Large Resource Type VPD-R
24Length [7:0] LSB0x51
25Length [15:8] MSB0x00
26VPD KeywordPNSTRAdd in Card Part Number
28Length0x15
29Part NumberPN%STR_SPC
50VPD KeywordECSTREngineering Change Level of
52Length0x3
53RevisionRV%STRPCB revision
56VPD KeywordSNSTRSerial Number
58Length0x14
ItemValueFormatDescription
0x82
String Tag (0x02)
STR
Mezz
0x90
Tag (0x10)
the card (rev)
Mellanox Technologies
13
Page 14
Table 5 - 0J05YT VPD Layout
Card InterfacesRev 1.0
Offset
(Decimal)
59SerialNumberOO0J05YTMMM
79VPD KeywordV0STRMisc Information
81Length0x15
82DataVPI QDR SFF
103VPD KeywordRVSTR
105Length0x1
106Data0,105%CS0
107Large Resource Type VPD-W
108Length [7:0] LSB0x91
109Length [15:8] MSB0xF
110VPD KeywordV1STREFI Driver version
112Length0x6
113DataN/ASTR_SPC
119VPD KeywordYASTRAsset Tag
121Length0x18
122DataN/ASTR_SPC“N/A”
146VPD KeywordRWSTRRemaining read/write area
148Length0x6b
149DataSTR_ZEROReserved (0x00)
256VPD KeywordRWSTRRemaining read/write area
258Length0xfd
259DataSTR_ZEROReserved (0x00)
512VPD KeywordRWSTRRemaining read/write area
514Length0xfd
515DataSTR_ZEROReserved (0x00)
768VPD KeywordRWSTRRemaining read/write area
770Length0xfd
771DataSTR_ZEROReserved (0x00)
1024VPD KeywordRWSTRRemaining read/write area
1026Length0xfd
1027DataSTR_ZEROReserved (0x00)
1280VPD KeywordRWSTRRemaining read/write area
1282Length0xfd
1283DataSTR_ZEROReserved (0x00)
1536VPD KeywordRWSTRRemaining read/write area
1538Length0xfd
1539DataSTR_ZEROReserved (0x00)
1792VPD KeywordRWSTRRemaining read/write area
1794Length0xfd
1795DataSTR_ZEROReserved (0x00)
2048VPD KeywordRWSTRRemaining read/write area
ItemValueFormatDescription
%STR_SPC“00..00XXXX..XX”
MMYMDSSSS
STR_SPC
mezz
0x91
Tag (0x11)
14
Mellanox Technologies
Page 15
ConnectX®-3 Dual Port 40Gb/s and 56Gb/s Mezzanine Card for Dell User ManualRev 1.0
Table 5 - 0J05YT VPD Layout
Offset
(Decimal)
2050Length0xfd
2051DataSTR_ZEROReserved (0x00)
2304VPD KeywordRWSTRRemaining read/write area
2306Length0xfd
2307DataSTR_ZEROReserved (0x00)
2560VPD KeywordRWSTRRemaining read/write area
2562Length0xfd
2563DataSTR_ZEROReserved (0x00)
2816VPD KeywordRWSTRRemaining read/write area
2818Length0xfd
2819DataSTR_ZEROReserved (0x00)
3072VPD KeywordRWSTRRemaining read/write area
3074Length0xfd
3075DataSTR_ZEROReserved (0x00)
3328VPD KeywordRWSTRRemaining read/write area
3330Length0xfd
3331DataSTR_ZEROReserved (0x00)
3584VPD KeywordRWSTRRemaining read/write area
3586Length0xfd
3587DataSTR_ZEROReserved (0x00)
3840VPD KeywordRWSTRRemaining read/write area
3842Length0xfc
3843DataSTR_ZEROReserved (0x00)
4095Small Resource Type END
ItemValueFormatDescription
0x78
Tag (0x11)
Table 6 - 0K6V3V VPD Layout
Offset
(Decimal)
0Large Resource Type ID
1Length [7:0] LSB0x14
2Length [15:8] MSB0x0
3DataDELL ConnectX-3
23Large Resource Type VPD-R
24Length [7:0] LSB0x4D
25Length [15:8] MSB0x00
26VPD KeywordPNSTRAdd in Card Part Number
28Length0x15
29Part NumberPN%STR_SPC
50VPD KeywordECSTREngineering Change Level of
52Length0x3
ItemValueFormatDescription
0x82
String Tag (0x02)
STR
Mezz
0x90
Tag (0x10)
the card (rev)
Mellanox Technologies
15
Page 16
Table 6 - 0K6V3V VPD Layout
Card InterfacesRev 1.0
Offset
(Decimal)
53RevisionRV%STRPCB revision
56VPD KeywordSNSTRSerial Number
58Length0x14
59SerialNumberOO0K6V3VMMM
79VPD KeywordV0STRMisc Information
81Length0x11
82DataVPI FDR SFF
99VPD KeywordRVSTR
101Length0x1
102Data0,101%CS0
103Large Resource Type VPD-W
104Length [7:0] LSB0x95
105Length [15:8] MSB0xF
106VPD KeywordV1STREFI Driver version
108Length0x6
109DataN/ASTR_SPC
115VPD KeywordYASTRAsset Tag
117Length0x18
118DataN/ASTR_SPC“N/A”
142VPD KeywordRWSTRRemaining read/write area
144Length0x6f
145DataSTR_ZEROReserved (0x00)
256VPD KeywordRWSTRRemaining read/write area
258Length0xfd
259DataSTR_ZEROReserved (0x00)
512VPD KeywordRWSTRRemaining read/write area
514Length0xfd
515DataSTR_ZEROReserved (0x00)
768VPD KeywordRWSTRRemaining read/write area
770Length0xfd
771DataSTR_ZEROReserved (0x00)
1024VPD KeywordRWSTRRemaining read/write area
1026Length0xfd
1027DataSTR_ZEROReserved (0x00)
1280VPD KeywordRWSTRRemaining read/write area
1282Length0xfd
1283DataSTR_ZEROReserved (0x00)
1536VPD KeywordRWSTRRemaining read/write area
1538Length0xfd
1539DataSTR_ZEROReserved (0x00)
1792VPD KeywordRWSTRRemaining read/write area
ItemValueFormatDescription
%STR_SPC“00..00XXXX..XX”
MMYMDSSSS
STR_SPC
mezz
0x91
Tag (0x11)
16
Mellanox Technologies
Page 17
ConnectX®-3 Dual Port 40Gb/s and 56Gb/s Mezzanine Card for Dell User ManualRev 1.0
Table 6 - 0K6V3V VPD Layout
Offset
(Decimal)
1794Length0xfd
1795DataSTR_ZEROReserved (0x00)
2048VPD KeywordRWSTRRemaining read/write area
2050Length0xfd
2051DataSTR_ZEROReserved (0x00)
2304VPD KeywordRWSTRRemaining read/write area
2306Length0xfd
2307DataSTR_ZEROReserved (0x00)
2560VPD KeywordRWSTRRemaining read/write area
2562Length0xfd
2563DataSTR_ZEROReserved (0x00)
2816VPD KeywordRWSTRRemaining read/write area
2818Length0xfd
2819DataSTR_ZEROReserved (0x00)
3072VPD KeywordRWSTRRemaining read/write area
3074Length0xfd
3075DataSTR_ZEROReserved (0x00)
3328VPD KeywordRWSTRRemaining read/write area
3330Length0xfd
3331DataSTR_ZEROReserved (0x00)
3584VPD KeywordRWSTRRemaining read/write area
3586Length0xfd
3587DataSTR_ZEROReserved (0x00)
3840VPD KeywordRWSTRRemaining read/write area
3842Length0xfc
3843DataSTR_ZEROReserved (0x00)
4095Small Resource Type END
ItemValueFormatDescription
0x78
Tag (0x11)
Mellanox Technologies
17
Page 18
Card InstallationRev 1.0
3Card Installation
3.1Hardware RequirementsTBD
Before installing the mezzanine card, make sure that the system meets the hardware and software
requirements listed in
Table 7 - Jumper Configuration
RequirementDescription
HardwareUsed with Dell Blade Servers
Software Operating Sys-
tems/Distributions
3.2Installation Kit
Make sure all of the parts are in the kit before you start the installation. If any parts are damaged or
missing, call your supplier immediately.
Installation Instructions
Refer to the Dell Blade Servers Manuals
18
Installation of this mezzanine card should only be done by a properly qualified technician or engineer. Installation or service not authorized by Dell or performed by unqualified personnel may
void guarantees and warranties. Read and follow all safety precautions specified in this document
and in the PowerEdge documentation.
Mellanox Technologies
Page 19
ConnectX®-3 Dual Port 40Gb/s and 56Gb/s Mezzanine Card for Dell User ManualRev 1.0
Use the documentation supplied with the Dell Blade Servers to remove and replace the blade from
the chassis.
The card shown below has grounding clips that must come in contact with the chassis after the
card is installed.
Figure 7: Grounding Clip
Make sure that you are properly grounded. Make sure that the equipment, both while in the chassis and while removed from the chassis, is properly grounded to prevent ESD.
Figure 8: Blade Server
DIMMS
Mellanox Technologies
19
Page 20
DIMMS can be hot. Allow sufficient time for the blade components to cool before starting this
procedure.
1.Remove the blade from the chassis.
2.Remove the cover from the blade.
3.Open the retaining clip.
The card can be placed in either of the two available slots.
4.Expose the socket to be used for the new card.
a. When replacing an existing card, remove the card from the socket. Grab the card on the edge
on the side with UPC number and pull up while gently rocking the card back and forth.
For a new installation remove the protective cover enclosing the socket for the card.
b.
Figure 9: Protective Cover in Place
Card InstallationRev 1.0
20
Mellanox Technologies
Page 21
ConnectX®-3 Dual Port 40Gb/s and 56Gb/s Mezzanine Card for Dell User ManualRev 1.0
Figure 10: Remove the Cover
Hold the mezzanine card by the edges only.
Line up the mezzanine card so that the pins of the mezzanine card are over the sockets in the blade
server.
5.Plug the card into the socket by placing your thumb over the UPC symbol and pressing down
until the card reaches the bottom.
Figure 11: Press on the Card
6.Close the retaining clip.
Mellanox Technologies
21
Page 22
Figure 12: Single Card in Slot C
Figure 13: Two Cards Installed
Card InstallationRev 1.0
22
7.Replace the blade server cover.
8.Replace the blade server into the chassis
Mellanox Technologies
Page 23
ConnectX®-3 Dual Port 40Gb/s and 56Gb/s Mezzanine Card for Dell User ManualRev 1.0
3.3Safety Warnings
1. Installation Instructions
Read all installation instructions before connecting the equipment to the power source.
2. Over Temperature
This equipment should not be operated in an area with an ambient temperature exceeding the
maximum recommended: °C (°F).
To guarantee proper air flow, allow at least 8cm (3 inches) of clearance around the ventilation
openings.
3. Lightening – Electrical Hazard
During periods of lightning activity, do not work on the equipment.
4. Installation of Equipment
This equipment should be installed, replaced, or serviced only by trained and qualified personnel.
5. Disposal of Equipment
Disposal of this equipment should be in accordance to all national laws and regulations.
=
6. Compliance with Local and National Codes
This equipment should be installed in compliance with local and national electrical codes.
Mellanox Technologies
23
Page 24
4Driver Software and Firmware
4.1Driver Software
4.1.1 Linux
For Linux, download and install the latest OpenFabrics Enterprise Distribution (OFED) software
package available via the Mellanox web site at: http://www.mellanox.com => Products => Soft-
ware/Drivers => Infiniband & VPI Software/Drivers => Mellanox OFED => Download. Follow
the installation instructions included in the download package (also available from the download
To ensure that communication has been established follow the instructions below.
page).
Check the link status
To check the IB link status, for IB cards, run “ibstat” and focus on the Physical state attributes.
Driver Software and FirmwareRev 1.0
Example:
> Host# ibstat
LCA 'mlx4_0'
CA type: MT4099
Number of ports: 2
Firmware version: 2.10.2000
Hardware version: 0
Node GUID: 0x0002c903002fefe0
System image GUID: 0x0002c903002fefe3
Port 1:
State: Active
Physical state: LinkUp
Rate: 56
Base lid: 4
LMC: 0
SM lid: 12
24
Capability mask: 0x02514868
Port GUID: 0x0002c903002fefe1
Link layer: InfiniBand
Port 2:
State: Active
Physical state: LinkUp
Mellanox Technologies
Page 25
ConnectX®-3 Dual Port 40Gb/s and 56Gb/s Mezzanine Card for Dell User ManualRev 1.0
Rate: 56
Base lid: 8
LMC: 0
SM lid: 12
Capability mask: 0x02514868
Port GUID: 0x0002c903002fefe2
Link layer: InfiniBand
Check the OFED version
To get the version of the running Mellanox OFED/BXOFED, run the following command:
For troubleshooting driver installation, please check Mellanox OFED driver user manual ar
http://www.mellanox.com => Support => InfiniBand Products => Mellanox OFED.
4.1.2 Windows
For Windows, download and install the latest Mellanox WinOF VPI for Windows software package available via the Mellanox web site at: http://www
Drivers => Infiniband & VPI Software/Drivers => Mellanox WinOF VPI => Download. Follow
the installation instructions included in the download package (also available from the download
page). To ensure that communication has been established follow the instructions below.
Displaying the Device Manager will show the Mellanox adapter devices and an IPoIB (network)
device for each port.
MLNX_OFED_LINUX-1.5.3-0.1.6 (OFED-1.5.3-0.1.6):
.mellanox.com => Products => Software/
Mellanox Technologies
25
Page 26
Driver Software and FirmwareRev 1.0
Figure 14: Device Manager (example)
Note:If the cards are connected to a managed switch, there is no need to run openSM. Only
one OpenSM should run per subnet.In InfiniBand interfaces, OpenSM is installed as a
disabled Windows service. To enable it, enter at the command line:
> sc start opensm
4.2FlexBoot
FlexBoot enables remote boot over Boot over InfiniBand (BoIB), or Boot over iSCSI (Bo-iSCSI).
This technology is based on the Preboot Execution Environment (PXE) standard specification, and
FlexBoot software is based on the open source EtherBoot/gPXE project (see www.etherboot.org).
For more information go to http://www.mellanox.com => Products => InfiniBand & VPI Soft-
ware/Drivers => FlexBoot => User’s Manual.
4.3Updating Mezzanine Card Firmware
Each card is shipped with the latest version of qualified firmware at the time of manufacturing.
Firmware is updated occasionally, and the most recent firmware can be obtained from:
http://www.mellanox.com => Support => Download Firmware. Check that the firmware on your
card is the latest found on the Mellanox site, if not update to the latest version found on the Mellanox web site.
Firmware can be updated on the stand alone single card using the flint tool of the Mellanox Firm-ware Tools (MFT) package.
from the Mellanox Firmware Tools page. See http://www.mellanox.com => Support => Download
Firmware Tools.
This package is available for download, along with its user manual,
26
A firmware binaries table lists a binary file per mezzanine card. The file name of each such binary
is composed by combining the firmware name, the firmware release version, and the card part
Mellanox Technologies
Page 27
ConnectX®-3 Dual Port 40Gb/s and 56Gb/s Mezzanine Card for Dell User ManualRev 1.0
number. Please contact Mellanox System Support if you cannot find the firmware binary for your
mezzanine card.
The following steps describe how to retrieve the PSID (firmware identification) and programmed
firmware version of your mezzanine card. They also describe how to update the card with the lat
-
est firmware version available.
1.Retrieve the PSID and firmware version:
a. Install the MFT package. The package is available at www.mellanox.com => Products =>
Software/Drivers => InfiniBand & VPI Software/Drivers => Firmware Tools. Make sure to
download the package corresponding to your computer’s operating system.
b. Enter: mst start
c. Get the Mellanox mst device name using the command "mst status". The mst device name will be of
the form: /dev/mst/mt4099_pci_cr0
d. Get the PSID (firmware identification) and programmed firmware version using the command
Please refer to "Mellanox Products Approved Cable Lists" at www.mellanox.com/related-
docs/user_manuals/Mellanox_approved_cables.pdf
a. Air flow is measured ~1” from the heat sink between the heat sink and the cooling air inlet.
30
Mellanox Technologies
Page 31
ConnectX®-3 Dual Port 40Gb/s and 56Gb/s Mezzanine Card for Dell User ManualRev 1.0
Appendix B: Avertissements de sécurité d’installation
(French)
1. Instructions d’installation
Lisez toutes les instructions d’installation avant de brancher le matériel à la
source d’alimentation électrique.
2. Température excessive
Ce matériel ne doit pas fonctionner dans une zone avec une température ambiante dépassant le maximum recommandé de 55°C (131°F). Un flux d’air de
200LFM à cette température ambiante maximale est nécessaire. En outre, pour
garantir un bon écoulement de l’air
libre autour des ouvertures de ventilation.
3. Orages – dangers électriques
Pendant un orage, il ne faut pas utiliser le matériel.
4. Installation du matériel
, laissez au moins 8 cm (3 pouces) d’espace
Ce matériel ne doit être installé, remplacé ou entretenu que par du personnel
formé et qualifié.
5. Elimination du matériel
L’élimination de ce matériel doit s’effectuer dans le respect de toutes les législations et réglementations nationales en vigueur.
6. Codes électriques locaux et nationaux
Ce matériel doit être installé dans le respect des codes électriques locaux et
nationaux.
Lesen Sie alle Installationsanleitungen, bevor Sie das Gerät an die Stromversorgung anschließen.
2. Übertemperatur
Dieses Gerät sollte nicht in einem Bereich mit einer Umgebungstemperatur
über der maximal empfohlenen Temperatur von 55°C (131°F) betrieben
werden. Außerdem sollten mindestens 8 cm (3 in.) Freiraum um die Belüftungsöffnungen sein, um einen einwandfreien Luftstrom zu gewährleisten.
3. Bei Gewitter - Elektrische Gefahr
Arbeiten Sie während eines Gewitters und Blitzschlag nicht am Gerät.
4. Geräteinstallation
Diese Gerät sollte nur von geschultem und qualifiziertem Personal installiert,
ausgetauscht oder gewartet werden.
32
5. Geräteentsorgung
Die Entsorgung dieses Geräts sollte unter Beachtung aller nationalen Gesetze
Bestimmungen erfolgen.
6. Regionale und nationale elektrische Bestimmungen
Dieses Gerät sollte unter Beachtung der regionalen und nationalen elektrischen
Bestimmungen installiert werden.
Mellanox Technologies
Page 33
ConnectX®-3 Dual Port 40Gb/s and 56Gb/s Mezzanine Card for Dell User ManualRev 1.0
Appendix D: Advertencias de seguridad para la instalación
(Warnings in Spanish)
1. Instrucciones de instalación
Antes de conectar el equipo a la fuente de alimentación, leer todas las instrucciones de
instalación.
2. Sobrecalentamiento
No se debe utilizar el equipo en un área con una temperatura ambiente superior a la
máxima recomendada: 55°C(131°F). Además, para garantizar una circulación de aire
adecuada, se debe dejar como mínimo un espacio de 8 cm (3 pulgadas) alrededor de las
aberturas de ventilación.
3. Cuando hay rayos: peligro de descarga eléctrica
No utilizar el equipo ni conectar o desconectar cables durante períodos de actividad de
rayos.
4. Instalación de equipos
La instalación, el reemplazo y el mantenimiento de este equipo estarán a cargo únicamente de personal capacitado y competente.
5. Eliminación de equipos
La eliminación definitiva de este equipo se debe efectuar conforme a todas las leyes y
reglamentaciones nacionales.
6. Códigos eléctricos locales y nacionales
Este equipo se debe instalar conforme a los códigos eléctricos locales y nacionales.
Mellanox Technologies
33