Delfield Installation, Operation And Maintenance Manual
Specifications and Main Features
Frequently Asked Questions
User Manual
Series CS Reach-Ins
CoolScapes™
Original Instructions
Installation, Operation and Maintenance Manual
This manual is updated as new information and models are released. Visit our website for the latest manual.
Part Number: 9295040 07/17
Safety Notices
Warning
n
Read this manual thoroughly before operating, installing
or performing maintenance on the equipment. Failure
to follow instructions in this manual can cause property
damage, injury or death.
DANGER
Do not install or operate equipment that has been misused,
abused, neglected, damaged, or altered/modified from
that of original manufactured specifications.
DANGER
Use appropriate safety equipment during installation and
servicing.
DANGER
All utility connections and fixtures must be maintained in
accordance with Local and national codes.
Warning
n
Do not damage the refrigeration circuit when installing,
maintaining or servicing the unit.
Warning
n
Do not use electrical appliances or accessories other than
those supplied by the manufacturer.
Warning
n
Use caution when handling metal surface edges of all
equipment.
Warning
n
This appliance is not intended for use by persons
(including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge,
unless they have been given supervision concerning use
of the appliance by a person responsible for their safety.
Do not allow children to play with this appliance.
Caution
,
Use caution handling, moving and use of the R290
refrigerators to avoid either damaging the refrigerant
tubing or increasing the risk of a leak. Components shall
be replaced with like components. Servicing shall be done
by a factory authorized service personnel to minimize the
risk of possible ignition due to incorrect parts or improper
service.
Warning
n
Authorized Service Representatives are obligated to follow
industry standard safety procedures, including, but not
limited to, local/national regulations for disconnection
/ lock out / tag out procedures for all utilities including
electric, gas, water and steam.
Warning
n
Do not store or use gasoline or other flammable vapors
or liquids in the vicinity of this or any other appliance.
Never use flammable oil soaked cloths or combustible
cleaning solutions, for cleaning.
Warning
n
This product contains chemicals known to the State of
California to cause cancer and/or birth defects or other
reproductive harm. Operation, installation, and servicing
of this product could expose you to airborne particles
of glasswool or ceramic fibers, crystalline silica, and/
or carbon monoxide. Inhalation of airborne particles
of glasswool or ceramic fibers is known to the State of
California to cause cancer. Inhalation of carbon monoxide
is known to the State of California to cause birth defects
or other reproductive harm.
Notice
Proper installation, care and maintenance are essential
for maximum performance and trouble-free operation of
your equipment. Visit our website www.mtwkitchencare.
com for manual updates, translations, or contact
information for service agents in your area.
Notice
Warranty may be deemed invalid if other than authorized
OEM (original equipment manufacture) replacement
parts are used in Delfield equipment.
Section 1
General Information
Section 2
Installation
Section 3
Operation
Table of Contents
Model Numbers ................................................................................................................ 5
Serial Number Information ................................................................................................ 5
Cleaning the Condenser Coil ............................................................................................ 26
4 Part Number: 9295040 07/17
Section 1
General Information
Model Numbers
This manual covers the following models:
One SectionTwo SectionThree Section
Reach-In Dual Temperature
CSDBR1P-SH-CSDTR1P-SH--
Reach-In Freezers
CSF1P-S (H)CSF2P-S (H)CSF3P-S (H)
Pass-Thru Freezers
CSFPT1P-S (H)CSFPT2P-S (H)-
Roll-In Freezers
CSFRI1P-SCSFRI2P-S
Reach-In Heated Cabinets
CSH1-G (H)CSH2-G (H)-
CSH1-S (H)CSH2-S (H)-
Pass-Thru Heated Cabinets
CSHPT1-G (H)CSHPT2-G (H)-
CSHPT1-S (H)CSHPT2-S (H)-
Roll-In Heated Cabinets
CSHRI1-GCSHRI2-G-
CSHRI1-SCSHRI2-S-
Roll-Thru Heated Cabinets
CSHRT1-SCSHRT2-S-
Narrow Reach-In Refrigerators
CSR1NP-G (H)CSR2NP-G (H)-
CSR1NP-S (H)CSR2NP-S (H)-
Reach-In Refrigerators
CSR1P-G (H)CSR2P-G (H)CSR3P-G (H)
-CSR2P-GL-
CSR1P-S (H)CSR2P-S (H)CSR3P-S (H)
Pass-Thru Refrigerators
CSRPT1P-G (H)CSRPT2P-G (H)-
CSRPT1P-S (H)CSRPT2P-S (H)-
Roll-In Refrigerators
CSRRI1P-GCSRRI2P-G-
CSRRI1P-SCSRRI2P-S-
Roll-Thru Refrigerators
CSRRT1P-SCSRRT2P-S-
Serial Number Information
The model number and serial number are on the
identification plate. The identification plate is located near
the top front corner of the left interior wall.
Always have the serial number of your unit available
when calling for parts or service.
Warranty Information
Visit
http://www.delfield.com/warranty to:
• Register your product for warranty.
• Verify warranty information.
• View and download a copy of your warranty.
Regulatory Certifications
Models are certified by:
•
•
•
National Sanitation Foundation (NSF)
Underwriters Laboratories (UL)
Underwriters Laboratories of Canada (cUL)
Part Number: 9295040 07/17 5
General Information Section 1
THIS PAGE INTENTIONALLY LEFT BLANK
6 Part Number: 9295040 07/17
Section 2
Installation
DANGER
Installation must comply with all applicable fire and
health codes in your jurisdiction.
DANGER
Use appropriate safety equipment during installation and
servicing.
Location
Warning
n
This equipment must be positioned so that the plug is
accessible unless other means for disconnection from the
power supply (e.g., circuit breaker or disconnect switch)
is provided.
Warning
n
Adequate means must be provided to limit the movement
of this appliance without depending on or transmitting
stress to the electrical cord.
Warning
n
To avoid instability the installation area must be capable
of supporting the combined weight of the equipment
and product. Additionally the equipment must be level
side to side and front to back.
The location selected for the equipment must meet the
following criteria. If any of these criteria are not met, select
another location.
• Units are intended for indoor use only.
• The location MUST be level, stable and capable of
supporting the weight of the equipment.
• The location MUST be free from and clear of combustible
materials.
• Equipment MUST be level both front to back and side to
side.
• Position the equipment so it will not tip or slide.
• Front casters MUST be locked once positioned.
• Recommended air temperature is 60° - 100°F
(16° - 38°C).
• Proper air supply for ventilation is REQUIRED AND
CRITICAL for safe and efficient operation. Refer to
Clearance Requirements chart on page 8.
• Do not obstruct the flow of ventilation air. Make sure the
air vents of the equipment are not blocked.
• Do not install the equipment directly over a drain. Steam
rising up out of the drain will adversely affect operation,
air circulation, and damage electrical / electronic
components.
Warning
n
This equipment is intended for indoor use only. Do not
install or operate this equipment in outdoor areas.
Part Number: 9295040 07/17 7
Installation Section 2
Clearance Requirements
DANGER
Minimum clearance requirements are the same for
noncombustible locations as for combustible locations.
The flooring under the appliance must be made of a
noncombustible material.
DANGER
Risk of fire/shock. All minimum clearances must be
maintained. Do not obstruct vents or openings.
Top
12.00” (305mm)
• Keep the vents clean and free of obstruction.
• Casters or optional legs must be used and not removed.