Delfield KH2CR-72B Service Manual

by Deleld
Shelleyglas
®
by Deleld
Shelleysteel
®
Shelleyglas®/Shelleysteel
Service and Installation Manual
Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately.
CAUTION
Refrigerated, Heated and Non-Electrical Units
Important Information
Read Before Use
Please Save These Instructions!
February 2013
®
Shelleyglas
/Shelleysteel™ Service and Installation Manual
Important Warning And Safety Information
WARNING Read This Manual Thoroughly Before Operating, Installing, Or Performing Maintenance On The Equipment.
WARNING Failure To Follow Instructions In This Manual Can Cause Property Damage, Injury Or Death.
WARNING Do Not Store Or Use Gasoline Or Other Flammable Vapors Or Liquids In The Vicinity Of This Or Any Other
Appliance.
WARNING Unless All Cover And Access Panels Are In Place And Properly Secured, Do Not Operate This Equipment.
WARNING This Appliance Is Not Intended For Use By Persons Who Lack Experience Or Knowledge, Unless They Have
Been Given Supervision Or Instruction Concerning Use Of The Appliance By A Person Responsible For Their Safety.
WARNING This Appliance Is Not To Be Played With.
WARNING Do Not Clean With Water Jet.
WARNING Do Not Use Electrical Appliances Inside The Food Storage Compartment Of This Appliance.
CAUTION Observe the following:
• Minimum clearances must be maintained from all walls and combustible materials.
• Keep the equipment area free and clear of combustible material.
• Allow adequate clearance for air openings.
• Operate equipment only on the type of electricity indicated on the specification plate.
• Unplug the unit before making any repairs.
• Retain this manual for future reference.
2
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.deleld.com
Shelleyglas
Contents
Receiving & Inspecting Equipment ...........................................3
Serial Number Information ........................................................ 4
Warranty Information ................................................................. 4
Regulatory Certifications ............................................................ 4
Shelleyglas Specifications .......................................................5-6
Shelleysteel Specifications ......................................................7-8
Installation: Heated Units .......................................................... 9
Operation: Heated Units ............................................................. 9
Installation: Refrigerated Units ................................................10
Operation: LiquiTec Units ......................................................... 10
Pressure Control Settings ........................................................ 11
Maintenance ........................................................................12-13
Food Well Assembly.................................................................14
Wiring Diagrams .................................................................15-18
Replacement Parts List .......................................................19-20
Exploded Views & Replacement Parts ....................................21
Standard Labor Guidelines ......................................................22
Notes ........................................................................................ 23
®
/Shelleysteel™ Service and Installation Manual
Receiving And Inspecting The Equipment
Even though most equipment is shipped crated, care should be taken during unloading so the equipment is not damaged while being moved into the building.
1. Visually inspect the exterior of the package and skid or container. Any damage should be noted and reported to the delivering carrier immediately.
2. If damaged, open and inspect the contents with the carrier.
3. In the event that the exterior is not damaged, yet upon opening, there is concealed damage to the equipment notify the carrier. Notification should be made verbally as well as in written form.
4. Request an inspection by the shipping company of the damaged equipment. This should be done within 10 days from receipt of the equipment.
5. Check the lower portion of the unit to be sure legs or casters are not bent.
6. Also open the compressor compartment housing and visually inspect the refrigeration package. Be sure lines are secure and base is still intact.
7. Freight carriers can supply the necessary damage forms upon request.
8. Retain all crating material until an inspection has been made or waived.
Uncrating the Equipment
First cut and remove the banding from around the crate. Remove the front of the crate material, use of some tools will be required. If the unit is on legs remove the top of the crate as well and lift the unit off the skid. If the unit is on casters it can be "rolled" off the skid.
The units with LiquiTec technology cold pans contain a non-toxic eutectic fluid within a sealed inner liner. This fluid may leak if the tank is punctured so care must be taken when uncrating and setting in place. The eutectic fluid is non-toxic and may be flushed down a disposal drain. If the LiquiTec unit cold pans leak, immediately call the Delfield service department directly at 1-800-733-8821 not your local service agent.
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.deleld.com
3
®
Shelleyglas
/Shelleysteel™ Service and Installation Manual
Serial Number Information
If your unit is heated, the serial tag is located above the louvered panel near the on/off switch.
Refrigerated units have the serial tag located in the compressor area near the on/off switch.
Understorage units often have the serial tag located on the left inside the storage area.
All purpose counters, utility equipment or delivery carts do not require serial numbers but a model tag is placed at the top of the pylon on the back of the unit.
Always have the serial number of your unit available when calling for parts or service.
This manual covers standard units only. If you have a custom unit, consult the customer service department at the number listed below.
©2013 The Delfield Company. All rights reserved. Reproduction without written permission is prohibited. “Delfield” is a registered trademarks of The Delfield Company.
Warranty Information
Visit http://www.delfield.com/minisite/service/warranty_info to:
• Register your product for warranty.
• Verify warranty information.
• View and download a copy of your warranty.
Regulatory Certifications
Models are certified by:
National Sanitation Foundation (NSF)
Underwriters Laboratories (UL) Underwriters Laboratories of Canada (ULC)
4
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.deleld.com
®
Shelleyglas
/Shelleysteel™ Service and Installation Manual
Shelleyglas® Specifications
This manual covers standard units only. If you have a custom unit, consult the customer service department at the number listed below.
Heated Serving Counters
Model V/ Hz/Ph NEMA Plug Amperage
KH-2 120/208-230/60/1 14-20P 15.0
KH-3 120/208-230/60/1 14-30P 20.0
KH-4 120/208-230/60/1 14-50P 26.0
KH-5 120/208-230/60/1 14-50P 31.0
KH-6 120/208-230/60/1 14-50P 37.0
KH-2-NU 120/208-230/60/1 14-20P 11. 0
KH-3-NU 120/208-230/60/1 14-20P 16.0
KH-4-NU 120/208-230/60/1 14-30P 22.0
KH-5-NU 120/208-230/60/1 14-50P 28.0
KH-6-NU 120/208-230/60/1 14-50P 33.0
Refrigerated Cold Pan Serving Counters
Model V/ Hz/Ph NEMA Plug Amperage H.P. Refrigerant BTU
KCSC-36B 115/60/1 5-15P 7. 0 1/4 404a 1102
KCSC-50B 115/60/1 5-15P 7. 0 1/4 404a 1240
KCSC-60B 115/60/1 5-15P 7. 0 1/4 404a 1343
KCSC-74B 115/60/1 5-15P 7. 0 1/4 404a 1423
KCSC-96B 115/60/1 5-15P 7. 0 1/4 404a 1487
Shelleyglas with LiquiTec
Model V/ Hz/Ph NEMA Plug Amperage H.P. Refrigerant BTU
KCSC-36-EF 115/60/1 5-15P 7. 0 1/4 404a 1102
KCSC-50-EF 115/60/1 5-15P 7. 0 1/4 404a 1240
KCSC-60-EF 115/60/1 5-15P 7. 0 1/4 404a 1343
KCSC-74-EF 115/60/1 5-15P 7. 0 1/4 404a 1423
KCSC-96-EF 115/60/1 5-15P 7. 0 1/4 404a 1487
Heated and Refrigerated Combo Counters
Model V/ Hz/Ph NEMA Plug Amperage H.P. Refrigerant BTU
KHCR-50-B 120/60/1 5-20P 16.0 1/4 404a 110 2
KHCR-60-B 120/60/1 5-20P 16.0 1/4 404a 110 2
KHCR-74-B 120/60/1 5-20P 16.0 1/4 404a 110 2
KHCR-96-B 120/60/1 5-20P 16.0 1/4 404a 1240
KH2CR-72-B 120/208-230/60/1 14-30P 18.0 1/4 404a 11 0 2
KH2CR-96-B 120/208-230/60/1 14-30P 18.0 1/4 404a 1343
KH3CR-96-B 120/208-230/60/1 14-30P 23.0 1/4 404a 1240
KH4CR-96-B 120/208-230/60/1 14-50P 29.0 1/4 404a 110 2
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.deleld.com
5
®
Shelleyglas
/Shelleysteel™ Service and Installation Manual
Shelleyglas® Specifications, continued
Heated and Ice Cooled Combo Counters
Model V/ Hz/Ph NEMA Plug Amperage
KHC-50-NU 120/60/1 5-15P 9.0
KHC-60-NU 120/60/1 5-15P 9.0
KHC-74-NU 120/60/1 5-15P 9.0
KHC-96-NU 120/60/1 5-15P 9.0
KH2C-74-NU 120/208-230/60/1 14-20P 11. 0
KH2C-96-NU 120/208-230/60/1 14-20P 11. 0
KH3C-74-NU 120/208-230/60/1 14-20P 16.0
KH3C-96-NU 120/208-230/60/1 14-20P 16.0
KH4C-96-NU 120/208-230/60/1 14-30P 22.0
Frost Top Serving Counters
Model V/ Hz/Ph NEMA Plug Amperage H.P. Refrigerant BTU
KCFT-36-NU 115/60/1 5-15P 7. 0 1/4 404a 435
KCFT-50-NU 115/60/1 5-15P 7. 0 1/4 404a 595
KCFT-60-NU 115/60/1 5-15P 7. 0 1/4 404a 717
KCFT-74-NU 115/60/1 5-15P 7. 0 1/4 404a 827
KCFT-96-NU 115/60/1 5-15P 7. 0 1/4 404a 921
Milk Counters
Model V/ Hz/Ph NEMA Plug Amperage H.P. Refrigerant BTU
KCM-36 115/60/1 5-15P 7. 0 1/4 404A 111 4
KCM-50 115/60/1 5-15P 7. 0 1/4 404A 1190
KCM-60 115/60/1 5-15P 7. 0 1/4 404A 1329
KCM-74 115/60/1 5-15P 7. 0 1/4 404A 1535
Ice Cream Counters
Model V/ Hz/Ph NEMA Plug Amperage H.P. Refrigerant BTU
KCF-36 115/60/1 5-15P 7. 1 1/4 404A 915
KCF-50 115/60/1 5-15P 7. 1 1/4 404A 1350
KCF-60 115/60/1 5-15P 8.0 1/3 404A 1456
KCF-74 115/60/1 5-15P 8.0 1/3 404A 1609
Milk and Ice Cream Counters
Model V/ Hz/Ph NEMA Plug Amperage H.P. Refrigerant BTU
REF/FRZ
KCFM-50 115/60/1 5-15P 7. 1 1/4 404A 789/1580
KCFM-74 115/60/1 5-15P 8.0 1/3 404A 1199/2040
Carving Counter
Model V/ Hz/Ph NEMA Plug Amperage
KRB 115/60/1 5-15P 5.0
6
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.deleld.com
®
Shelleyglas
/Shelleysteel™ Service and Installation Manual
Shelleysteel® Specifications
Heated Serving Counters
Model V/Hz/Ph NEMA Plug Amperage
SH-2 120/208-230/60/1 14-20P 15.0
SH-3 120/208-230/60/1 14-30P 20.0
SH-4 120/208-230/60/1 14-50P 26.0
SH-5 120/208-230/60/1 14-50P 31.0
SH-6 120/208-230/60/1 14-50P 37.0
SH-2-NU 120/208-230/60/1 14-20P 11. 0
SH-3-NU 120/208-230/60/1 14-20P 16.0
SH-4-NU 120/208-230/60/1 14-30P 22.0
SH-5-NU 120/208-230/60/1 14-50P 28.0
SH-6-NU 120/208-230/60/1 14-50P 33.0
Refrigerated Cold Pan Serving Counters
Model V/Hz/Ph NEMA Plug Amperage H.P. Refrigerant BTU
SCSC-36B 115/60/1 5-15P 7. 0 1/4 404a 110 2
SCSC-50B 115/60/1 5-15P 7. 0 1/4 404a 1240
SCSC-60B 115/60/1 5-15P 7. 0 1/4 404a 1343
SCSC-74B 115/60/1 5-15P 7. 0 1/4 404a 1423
SCSC-96B 115/60/1 5-15P 7. 0 1/4 404a 1487
Shelleysteel with LiquiTec
Model V/Hz/Ph NEMA Plug Amperage H.P. Refrigerant BTU
SCSC-36-EF 115/60/1 5-15P 7. 0 1/4 404a 110 2
SCSC-50-EF 115/60/1 5-15P 7. 0 1/4 404a 1240
SCSC-60-EF 115/60/1 5-15P 7. 0 1/4 404a 1343
SCSC-74-EF 115/60/1 5-15P 7. 0 1/4 404a 1423
SCSC-96-EF 115/60/1 5-15P 7. 0 1/4 404a 1487
Heated and Refrigerated Combo Counters
Model V/Hz/Ph NEMA Plug Amperage H.P. Refrigerant BTU
SHCR-50-B 120/60/1 5-20P 16.0 1/4 404a 110 2
SHCR-60-B 120/60/1 5-20P 16.0 1/4 404a 110 2
SHCR-74-B 120/60/1 5-20P 16.0 1/4 404a 110 2
SHCR-96-B 120/60/1 5-20P 16.0 1/4 404a 1240
SH2CR-62-B 120/208-230/60/1 14-20P 16.0 1/4 404a 1423
SH2CR-72-B 120/208-230/60/1 14-30P 18.0 1/4 404a 11 0 2
SH2CR-96-B 120/208-230/60/1 14-30P 18.0 1/4 404a 1343
SH3CR-96-B 120/208-230/60/1 14-30P 23.0 1/4 404a 1240
SH4CR-96-B 120/208-230/60/1 14-50P 29.0 1/4 404a 1102
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.deleld.com
7
®
Shelleyglas
/Shelleysteel™ Service and Installation Manual
Shelleysteel® Specifications, continued
Heated and Ice Cooled Combo Counters
Model V/Hz/Ph NEMA Plug Amperage
SHC-50-NU 120/60/1 5-15P 9.0
SHC-60-NU 120/60/1 5-15P 9.0
SHC-74-NU 120/60/1 5-15P 9.0
SHC-96-NU 120/60/1 5-15P 9.0
SHC2-62-NU 120/208-230/60/1 14-20P 11. 0
SH2C-74-NU 120/208-230/60/1 14-20P 11. 0
SH2C-96-NU 120/208-230/60/1 14-20P 11. 0
SH3C-74-NU 120/208-230/60/1 14-20P 16.0
SH3C-96-NU 120/208-230/60/1 14-20P 16.0
SH4C-96-NU 120/208-230/60/1 14-30P 22.0
Frost Top Serving Counters
Model V/Hz/Ph NEMA Plug Amperage H.P. Refrigerant BTU
SCFT-36-NU 115/60/1 5-15P 7. 0 1/4 404a 435
SCFT-50-NU 115/60/1 5-15P 7. 0 1/4 404a 595
SCFT-60-NU 115/60/1 5-15P 7. 0 1/4 404a 717
SCFT-74-NU 115/60/1 5-15P 7. 0 1/4 404a 827
SCFT-96-NU 115/60/1 5-15P 7. 0 1/4 404a 921
Milk Counters
Model V/Hz/Ph NEMA Plug Amperage H.P. Refrigerant BTU
SCM-36 115/60/1 5-15P 7. 0 1/4 404A 1114
SCM-50 115/60/1 5-15P 7. 0 1/4 404A 11 9 0
SCM-60 115/60/1 5-15P 7. 0 1/4 404A 1328
SCM-74 115/60/1 5-15P 7. 0 1/4 404A 1535
Ice Cream Counters
Model V/Hz/Ph NEMA Plug Amperage H.P. Refrigerant BTU
SCF-36 115/60/1 5-15P 7. 1 1/4 404A 915
SCF-50 115/60/1 5-15P 7. 1 1/4 404A 1350
SCF-60 115/60/1 5-15P 8.0 1/3 404A 1456
SCF-74 115/60/1 5-15P 8.0 1/3 404A 1609
Milk and Ice Cream Counter
Model V/Hz/Ph NEMA Plug Amperage H.P. Refrigerant BTU
SCFM-50 115/60/1 5-15P 7. 1 1/4 404A 789/1580
SCFM-74 115/60/1 5-15P 8.0 1/3 404A 1199/2040
Carving Counter
Model V/Hz/Ph NEMA Plug Amperage
SRB 115/60/1 5-15P 5.0
REF/FRZ
Trimline L-shaped Heated Serving Counter
Model V/Hz/Ph NEMA Plug Amperage
SLT4 (-L OR -R) 208-230/60/1 14-30P 22.0
8