Delfield F14EI348, F14EI460, F14EI572, F14EI688, F14GW232 Service Manual

...
F14 SERIES
Service and Installation Manual
Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately.
Hot Food Tables
IMPORTANT INFORMATION
READ BEFORE USE
PLEASE SAVE THESE INSTRUCTIONS!
Effective April 2010
F14 Series Service and Installation Manual
Important Warning And Safety Information
WARNING Read This Manual Thoroughly Before Operating, Installing, Or Performing
Maintenance On The Equipment.
WARNING Failure To Follow Instructions In This Manual Can Cause Property Damage,
Injury Or Death.
WARNING Do Not Store Or Use Gasoline Or Other Flammable Vapors Or Liquids In The
Vicinity Of This Or Any Other Appliance.
WARNING Unless All Cover And Access Panels Are In Place And Properly Secured, Do
Not Operate This Equipment.
WARNING Allow Heated Equipment To Cool Down Before Attempting To Clean Or
Service.
WARNING Do Not Clean With Water Jet.
CAUTION Observe the following:
Minimum clearances must be maintained from all walls and combustible
• materials.
Keep the equipment area free and clear of combustible material.
Allow adequate clearance for air openings.
Operate equipment only on the type of electricity indicated on the
• specification plate.
Unplug the unit before making any repairs.
Retain this manual for future reference.
2
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
F14 Series Service and Installation Manual
Contents
Serial Number Location ........................................................3
Receiving & Inspecting .........................................................3
Specifications ........................................................................4
Installation
F14EW & F14EI (electric) ................................................5
Operation
F14EI (electric) ................................................................6
F14EW (electric) .............................................................6
F14GW (gas) ...................................................................7
Maintenance ..........................................................................8
Wiring Diagrams
Domestic U.S. F14EI (electric) ........................................9
Domestic U.S. F14EW (electric) ....................................10
Export F14EI (electric) ..................................................11
Export F14EW (electric) ................................................12
Gas Burner Assembly: F14GW Series .................................13
Delfield Food Warmer (DFW) Assemblies
with thermostatic controls ............................................14
with infinite control .......................................................15
Miscellaneous Replacement Parts Lists ..............................16
Standard Labor Guidelines ..................................................17
Standard Warranty ..............................................................18
Additional Warranty ............................................................19
Serial Number Location
The serial number on all F14 Series hot food tables is printed on the tag located on the plate shelf.
Always have the serial number of your unit available when calling for parts or service. A complete list of authorized Delfield parts depots is is available at www.delfield.com.
©2010 The Delfield Company. All rights reserved. Reproduction without written permission is prohibited. “Delfield” is a registered trademark of The Delfield Company.
Receiving And Inspecting The Equipment
Even though most equipment is shipped crated, care should be taken during unloading so the equipment is not damaged while being moved into the building.
1. Visually inspect the exterior of the package and skid or container. Any damage should be noted and reported to the delivering carrier immediately.
2. If damaged, open and inspect the contents with the carrier.
3. In the event that the exterior is not damaged, yet upon opening, there is concealed damage to the equipment notify the carrier. Notification should be made verbally as well as in written form.
4. Request an inspection by the shipping company of the damaged equipment. This should be done within 10 days from receipt of the equipment.
5. Check the lower portion of the unit to be sure legs or
6. Also open the compressor compartment housing and
7. Freight carriers can supply the necessary damage forms
8. Retain all crating material until an inspection has been
Uncrating the Equipment
First cut and remove the banding from around the crate. Remove the front of the crate material, use of some tools will be required. If the unit is on legs remove the top of the crate and lift the unit off the skid. If the unit is on casters it can be "rolled" off the skid.
casters are not bent.
visually inspect the refrigeration package. Be sure lines are secure and base is still intact.
upon request.
made or waived.
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
3
F14 Series Service and Installation Manual
Domestic U.S Specifications
Electric with individual wells — wet or dry operation
Model
F14EI232
F14EI348
F14EI460
F14EI572
F14EI688
Electrical connections are 208/230 volt, 60 cycle, single phase. Each opening measures 11.87” x 19.87” (30.2cm x 50.5cm).
# Of Openings
2 10.0/11.0 216lbs/98kg
3 15.0/16.0 296lbs/134kg
4 20.0/22.0 376lbs/170kg
5 24.0/27.0 456lbs/207kg
6 29.0/32.0 536lbs/243kg
Amps 208V/230V Ship Weight
Electric with single tank — wet operation only
Model
F14EW232
F14EW348
F14EW460
F14EW572
F14EW688
Electrical connections are 120/240 volt, or optional 120/208 volt. (120 volt circuit is required for the low water cutoff.)
# Of Openings
2 21.0/24.0 316lbs/143kg
3 21.0/24.0 440lbs/199kg
4 21.0/24.0 500lbs/227kg
5 42.0/48.0 560lbs/254kg
6 42.0/48.0 660lbs/299kg
Amps 208V/240V Ship Weight
Gas with single tank — wet operation only
Model
F14GW232
F14GW348
F14GW460
F14GW572
F14GW688
*Each opening measures 11.87” x 19.87” (30.2cm x 50.5cm).
# Of Openings*
2 1 20000 256lbs/116kg
3 1 20000 326lbs/148kg
4 1 20000 396lbs/180kg
5 2 40000 456lbs/207kg
6 2 40000 536lbs/243kg
# Of Gas Burners BTU Ship Weight
Export Specifications
Export Electric with individual wells — wet or dry operation
Model
F14EI232-E
F14EI348-E
F14EI460-E
F14EI572-E
F14EI688-E
Electrical connections are 240 volt, 50 cycle, single phase. Each opening measures 11.87” x 19.87” (30.2cm x 50.5cm).
# Of Openings Temp Class
2 N 2900 216lbs/98kg
3 N 4350 296lbs/134kg
4 N 5800 376lbs/170kg
5 N 7250 456lbs/207kg
6 N 8700 536lbs/243kg
Export Electric with single tank — wet operation only
Model
F14EW232-E
F14EW348-E
F14EW460-E
Electrical connections are 240 volt, 50 cycle, single phase.
# Of Openings Temp Class
2 N 6000 316lbs/143kg
3 N 6000 440lbs/199kg
4 N 6000 500lbs/227kg
240V/50Hz Watts Ship Weight
240V/50Hz Watts Ship Weight
Export Gas with single tank — wet operation only
Model
F14GW232-E
F14GW348-E
F14GW460-E
F14GW572-E
F14GW688-E
*Each opening measures 11.87” x 19.87” (30.2cm x 50.5cm).
# Of Openings*
2 1 20000 256lbs/116kg
3 1 20000 326lbs/148kg
4 1 20000 396lbs/180kg
5 2 40000 456lbs/207kg
6 2 40000 536lbs/243kg
# Of Gas Burners BTU Ship Weight
4
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
F14 Series Service and Installation Manual
Installation: F14EI & F14EW Series (Electric)
Installation should only be done by personnel certified and licensed to install and maintain electrical appliances.
Location
Do not install the hot food table near any combustible objects or surfaces affected by heat or moisture.
Leveling
This unit must be level, both front and back and left to right, in order to maintain an equal water depth throughout the wells.
Plumbing
Hot water supply connection is provided 36” (91.4cm) above the floor, 3.12” (7.9cm) from the front left end at the rear of the unit. You must supply the required 1/2” (1.3cm) NPT connection. The minimum water pressure is 20psi (138kPa), the maximum water pressure is 80psi (552kPA).
A waste connection is provided 25” (63.5cm) above the floor, 7.5” (19.1cm) from the right end. You must supply the required 1” (2.5cm) NPT connection.
Electrical connection
Connections must be made in accordance with all applicable local codes and/or the National Electrical Code. Refer to the wiring diagrams in this manual.
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
5
F14 Series Service and Installation Manual
Operation: F14EI Series (Electric)
Before the unit is used the first time for serving, turn the temperature knob to “HI” and heat the well for 20 to 30 minutes. Any residue or dust that adhered to the heater element(s) will be burned off during this initial preheat period.
When using thick sauces, always operate the hot food well filled with water. This will provide a more uniform temperature for the sauce.
Steam can cause serious burns. Always wear some type of protective covering on your hands and arms when removing lids or pans from the unit. Lift the lid or pan in a way that will direct escaping steam away from your face and body.
Never place food directly into the well. Always use pans.
Although these models may be operated either with or without water in the wells, wet operation is recommended.
Always place covers on pans when not serving to prevent food from drying out and to reduce your operating cost.
For most efficient operation when empty, keep covered insets in each well during preheating and when the well is not in use.
Do not put food down drain.
Wet operation
1) Fill food well with 2” (50mm) of water. For quicker pre-heating, use hot water to fill the well.
2) Turn the control to “HIGH” and pre-heat the warmer for 30 minutes.
3) After pre-heating, set the control to your desired serving temperature.
Dry operation
1) Pre-heat the well on “HIGH” for approximately 15 minutes.
2) After pre-heating, set the control to your desired serving temperature.
Only 6” (15.2cm) deep insets should be used with a dry food well. When operated dry, the bottom of the food well will discolor. A mild abrasive cleaner is recommended to clean this discoloration.
Temperature
Water in wells . . . . . . . . . . . . . . . . .160°F to 180°F (71°C to 82°C)
Product in pans . . . . . . . . . . . . . . . 140°F to 160°F (60°C to 71°C)
Operation: F14EW Series (Electric)
These units must be operated with 4” (102mm) minimum water in the well. If operated dry, a low water safety switch will interrupt the electric supply to the heater to prevent heater failure. If the low water safety switch shuts off power, turn the control to the OFF position. If the water level is below the heating element, allow the well to cool completely, then refill with water. Reactivate the well by turning the control ON and resetting to the previous temperature.
Continuous interruption of power due to a low water level may disable the heater permanently. Pouring water on a hot heating element will damage it.
Steam can cause serious burns. Always wear some type of protective covering on your hands and arms when removing lids or pans from the unit. Lift the lid or pan in a way that will direct escaping steam away from your face and body.
Never place food directly into the well. Always use pans.
Always place covers on pans when not serving to prevent food from drying out and to reduce your operating cost.
For most efficient operation, when empty, keep covered insets in each well during preheating and when the well is not in use.
Wet operation
1) Fill food well with 4” (102mm) of water (heater must be covered by water). For quicker pre-heating, use hot water to fill the well.
2) Set the control to your desired serving temperature.
Temperature
Water in wells . . . . . . . . . . . . . . . . .160°F to 180°F (71°C to 82°C)
Product in pans . . . . . . . . . . . . . . . 140°F to 160°F (60°C to 71°C)
6
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
Loading...
+ 14 hidden pages