Delfi DelfiScan C51, DelfiScan C71 Programming Manual

Page 1
DelfiScan
Programming Manual
DelfiScan C51 and C71
Programming Manual
Page 2
DelfiScan
Programming Manual
Revision History
Rev.B Beta Apr. 16, 2009 First Release
Rev.B May 05, 2009
Page 22 Code 128/EAN-128 Setting – Modify ISBT Concatenation Off option code to “4
and ISBT Concatenation On option code to “5”.
Page 25 GS1 Databar Setting – All GS1 databar default values are changed to Enable. Page 45 Add “Symbology ID Table”.
Rev.B1 June 22, 2009
Page 34 Add “Presentation Scanning Mode”. Page 37 Add “Time Delay to Low Power Mode”.
Rev.B2 Aug. 21, 2009
Page 9, 11 Add “PDF417/Micro PDF417”, “Codablock F”, “Korea Post Code”. Page 26 Add “Composite Code Setting”, “PDF/MicroPDF417 Setting”, “Codablock F
Setting”, Korea Post Code Setting”.
Page 39 Add “Smar tStand Power Off Timeout”. Page 45 Add “PDF417/Micro PDF417”, “Codablock F”, “Korea Post Code” into Condensed
DataWizard Table.
Page 47 Add “PDF417/Micro PDF417”, “Codablock F”, “Composite Code”, “Korea Post
Code” into Symbology ID Table.
Rev.B3 Oct. 7, 2009
Page 8 Add “IBM PS/2, 25-30 series keyboard wedge interface”. Page 39 Add “Presentation Scanning Auto-sense”.
Page 3
DelfiScan
Programming Manual
Delfi Technologies A/S
Galoche Alle 1
DK-4600 Køge
Denmark
Telephone: + 45 70 222 555
Fax: + 45 70 222 666
An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be
reproduced or transmitted in any form or by any means without prior written per-mission of Delfi Technologies A/S. Owners of Delfi products
are hereby granted a non-exclusive, revocable license to reproduce and transmit this documentation for the purchaser's own internal business
purposes. Purchaser shall not remove or alter any proprietary notices, including copyright notices, contained in this documentation and shall
ensure that all notices appear on any reproductions of the documentation.
Electronic versions may either be downloadable from the Delfi website (www.delfi.com) or provided on appropriate media.
Disclaimer
Delfi has taken reasonable measures to provide information in this manual that is complete and accurate, however, Delfi reserves the right to
change any specification at any time without prior notice.
Regulatory
FCC part 15B
EN5
5022, EN55024, EN61000-3-2, EN61000-3-3
CNS13438
Industry Canada ICES-003
LED Eye Safety IEC60825-1, EN60825-1
Page 4
DelfiScan
Programming Manual
Table of Contents
Getting Started
Getting Familiar with Your DelfiScan 1
Connecting to Your Host 1
Using Accessaries
2
Configure Your DelfiScan
Bar Code Programming Manual 3
Programming Procedures 4
Host Interface Selection 8
Symbology Reading Control 9
Keyboard Interface Control 27
Serial Interface Control 31
Wand/Laser Emulation Control 34
Operation Control 35
Condensed DataWizard
41
Appendix
Symbology ID Table 48
Keyboard Function Code Table 49
ASCII Input Shortcut 50
Host Interface Quick Set 51
Operation Mode Quick Set 52
Option Codes 53
System Commands
54
Page 5
DelfiScan
Programming Manual
Getting Started
1
Power I ndicator
Status Indicator
Trigger
Scan Window
Beeper
Cable Release Hole
Getting Familiar with Your DelfiScan
Thank you for choosing Cino DelfiScan Imager. All DelfiScan imagers
deliver world-class performance for a broad range of applications to
unleash your productivity. This document provides an easy reference
for installation and operation purposes. A complete documentation is
provided by the DelfiScan Programming Manual available at
www.delfi.com
C71 Series
C51 Series
C
onnecting to Your Host
DelfiScan imagers support PS/2(DOS/V) Keyboard Wedge, RS-232
Serial, and USB interfaces. Please choose your desired interface
cable, then plug it into the cable interface port of the imager and
connect it to the host. If you would like to remove the cable, please
straighten one end of a paper clip, then insert it into the cable
release hole to pull out the cable.
USB
RS232 Se
rial
PS/2(DOS/V) Keyboard Wedge
Page 6
DelfiScan
Programming Manual
Getting Started
2
Using Accessories
You can enhance productivity of your workforce by using various
accessories to fulfill a wide variety of application demand.
Univ
ersal Holder
Hand-free SmartStand
A stylish Universal Holder is designed for
storing your imager when not in use. It
serves to protect the imager from
lens-scratched or falling. Moreover, its
artistic-design enhances the entire value of
the imager.
A SmartStand is specifically designed for hand-free applications to maximize user’s comfort and productivity. You can adjust the scanner holder to desired position for optimized scanning.
Thanks to the auto-sense design, the imager is capable of switching between presentation scanning and hand-held scanning automatically while working with SmartStand.
Please note that the SmartStand is not applicable for C51 Series imager.
Page 7
DelfiScan
Programming Manual
Configure Your DelfiScan
3
Bar Code Programming Menu
The DelfiScan bar code commands are specially designed Proprietary
bar code labels which allow you to set the DelfiScan internal
programming parameters. There are System Command, Family Code
and Option Code for programming purpose.
Each programmable family and bar code command label is listed on
the same page with major system commands. The detailed
explanations and special programming flowchart are printed on facing
or following pages. You can read the explanation and set the DelfiScan
concurrently.
A supplemental bar code command menu incorporates the bar code
command labels of System Command and Option Code. As you set the
DelfiScan, open the bar code command menu to find the option code
page. You may scan the desired family code and option code to set
DelfiScan. If you want to change the programming family for multiple
settings, you need only turn over the programming page to find next
desired programming family.
System Command
The System Command is the highest level bar code command which
directs DelfiScan to perform immediate operations, such as entering
programming mode (PROGRAM), exiting programming mode (EXIT),
listing system information (SYSLIST), recovering to factory preset
configurations (M_DEFAULT), and so on. Please note that all system
commands will take a few seconds to complete the operations. User
must wait for the completion beeps before scanning another bar code.
Family Code
The Family Code is scanned to select the user desired programming
family. DelfiScan has already provided more than one hundred
programming families to meet any specific requirements.
Option Code
The Option Codes is a set of bar code commands represented by
0–9”, “ A–F” and finishing selection (FIN). For most setting, you
must select at least one option code following the family code
selection to set the desired parameter for the selected
programming family.
Page 8
DelfiScan
Programming Manual
Configure Your DelfiScan
4
Programming Procedures
As you scan the bar code command to select the desired parameters,
information about the final selected parameters represented by the
bar code commands are stored in the DelfiScan’s internal Flash
Memory ASIC or non-volatile memory. If you turn off the unit, the
Flash Memory ASIC or non-volatile memory retains all programming
options. You need not re-program the DelfiScan if you want to keep
the existing configurations in the next power on.
The programming procedures of DelfiScan are designed as simple as
possible for ease of setting. Most programming families take the
Single Scan Selection programming procedure. But several
programming families have more complex and flexible
programmable options, and you must take Multiple Scans
Selection, Cycling Scan Selection or Dual Level Selection to
complete their programming procedures. Each kind of programming
procedure is listed in the following pages for your reference. Please
give careful attention to become familiar with each programming
procedure.
If the programming family must take multi
ple scans selection, cycling
scan selection, or dual level selection procedures, the family of the
programming menu will be marked with the matched representing
symbol of Programming Category (P.C.) in bold font listed in the
following table. You can easily find the bold mark in the
programming menu, and refer to their flowcharts for details. Before
setting the DelfiScan, please also refer to the “Beeping Indications”
listed in Appendix to understand the details of programming
beeping indications. It will be very helpful for you to know the
existing status while you are programming the DelfiScan.
Conventions of Programming Menu
Conventions Descriptions
Factory Default Value
P.C. Programming Category
SS
: Signle scan selection
MS
: Multiple scans selection
CS
: Cycling scan selecti
on
DS
: Dual level scan selection
( ) Necessary Option Code
[ ] Selectable Option Code
Page 9
DelfiScan
Programming Manual
Configure Your DelfiScan
5
Scan
“END”
DelfiScan will exit programming mode, and store all
parameters in Flash Memory ASIC or non-volatile memory,
then issue the completion beeping.
Scan
“P
ROGRAM”
DelfiScan will enter programming mode,
and inhibit all non-programming functions.
Scan
“SYSLIST”
DelfiScan will list the product information and
revision number to host via selected host interface,
then issue the completion beeping.
Scan
“M_DEFAULT”
DelfiScan will recover all programmable
parameters into factory preset configurations,
then issue the completion beeping.
Program & End System List, Group & Master Default
Plea
se note that the DelfiScan will take 3-4 seconds to store parameters in internal Flash Memory ASIC or non-volatile memory after you scan the “END”. P l e a s e don’t turn off the power before the completion beeping. It may destroy all configured parameters.
Page 10
DelfiScan
Programming Manual
Configure Your DelfiScan
6
Single scan selection
Multiple scans selection
Scan
“PROGRAM”
Scan
One of
Family
Codes
Scan
One of
Option
Codes
Repeat
Selection
Scan
“END”
No
Ye s
Enter programming mode.
Select one of desired
programming families.
Select one option code of
desired parameter.
Want to select another
programming family?
Exit programming mode.
Enter programming mode.
Select one of desired
programming families.
1. Select one or several
option codes to select
desired parameters.
2. If it’s necessary, scan
“FIN” to terminate
option code selection.
Want to select another
programming family?
Exit programming mode.
Scan
PROGRAM”
Scan
One of Family Codes
Scan One or
Several Option Codes
Repeat
Selection
Scan
“END”
No
Ye s
Page 11
DelfiScan
Programming Manual
Configure Your DelfiScan
7
Cycling scan selection Dual level selection
Enter programming mode.
Select one of desired
programming families.
Cycling select one or
several option codes of
desired parameters as
“Single” or “Multiple”
scans selection.
Finish cycling selection.
(If necessary)
Want to select another
programming family?
Exit programming mode.
Scan
“PROGRAM”
Scan
One of
Family
Codes
Scan
One of
Option
Codes
Repeat
Selection
Scan
“END”
No
Ye s
Scan “
FIN
Enter programming mode.
Select one of desired
programming families.
Select several option codes
of desired parameters.
1.
Select one or severa
l
o
ption codes of desired
parameters
.
2.
If it’s necessary, scan
“FIN” to terminate
option code selection.
Want to select another
programming family?
Exit programming mode.
Scan
One of Family Codes
(1st) Scan
Several Option Codes
Ye s
Scan
PROGRAM”
Repeat
Selection
Scan
END”
No
(2nd) Scan One or
Several Option Codes
Page 12
DelfiScan
Programming Manual
Configure Your DelfiScan
8
PROGR
AM
Host Interface Selection
M_DEF
AULT
Family Code Selection P.C Parameter Selection Option Code
Host Interface Selection
MS MS MS MS MS MS MS MS MS MS
IBM PS/2, 25-30 series keyboard wedge interface Standard/TTL RS-232 peer-to-peer serial Wand emulation USB Com Port Emulation PS/2 (DOS/V) direct link (keyboard replacement) PS/2 (DOS/V) keyboard wedge turbo mode PS/2 (DOS/V) keyboard wedge standard mode Laser emulation USB HID standard mode USB HID turbo mode
02 06 08 09 10 13 14 17 18 19
Page 13
DelfiScan
Programming Manual
Configure Your DelfiScan
9
PROGR
AM
Symbology Reading Control
User Defined Symbol ID
M_DEF
AULT
Family Code Selection
P.C Parameter Selection
Option Code 2nd Option Code
Symbol ID : 1 character
DS
Code 128 (default=B) UCC/EAN-128 (default=C) UPC-A (default=A) EAN-13 (default=F) Codabar/NW-7 (default=D) Code 39/Code 32 (default=G) Code 93 (default=H) Standard/Industrial 2 of 5 (default=I) Interleaved 2 of 5 (default=J) Matrix 2 of 5 (default=K) China Postal Code (default=L) German Postal Code (default=M) IATA (default=O) Code 11 (default=P) MSI/Plessey (default=R) UK/Plessey (default=S) Telepen (default=T) GS1 DataBar (default=X) UPC-E (default=E) EAN-8 (default=N) Trioptic Code 39 (Default=W) UCC Coupon Extended Code (Default=Z) PDF417/Micro PDF417 (default=V) Codablock F (default=Y) Korea Post Code (default =a)
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 26
(1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character)
Page 14
DelfiScan
Programming Manual
Configure Your DelfiScan
10
PROGR
AM
Symbology Reading Control
Symbology ID Transmission
M_DEF
AULT
Family Code Selection
P.C Parameter Selection
Option Code
Symbology ID Transmission
SS SS SS SS SS SS SS
Disable symbology ID transmission Enable prefix CINO symbology ID transmission Enable suffix CINO symbology ID transmission Enable both prefix and suffix CINO symbology ID transmission Enable prefix AIM symbology ID transmission Enable suffix AIM symbology ID transmission Enable both prefix and suffix AIM symbology ID transmission
0 1 2 3 4 5 6
Page 15
DelfiScan
Programming Manual
Configure Your DelfiScan
11
PROGRAM
Symbology Reading Control
Readable Bar Code Setting
M_D
EFAULT
Family Code Selection P.C Parameter Selection Option Code
Readable Symbology Setting
SS
CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS
Auto
Code 128 * UPC-A * UPC-E * EAN-13 * EAN-8 * Codabar/NW
-7 * Code 39 * Trioptic Code 39 Standard/Industrial 2 of 5 Matrix 2 of 5 Interleaved 2 of 5 * China Postal Code German Postal Code Code 93 * Code 11 MSI/Plessey UK/Plessey Telepen GS1 DataBar (RSS-14) * IATA PDF417/Micro PDF417 Codablock F Korea Post Code
00 01 02 03 04 05 06 07 47 08 38 48 58 68 09 10 11 12 13 14 15 17 18 21
If your application is reading known, limited bar code symbologies, you may increase the reading speed and decrease the reading error possi
bility by
selecting th
ose known symbologies only. Furthermore, to add the “
Symbology ID
” into the transmitted data is also helpful for applications to identify
the specific symbology ID
.
Above symb
ologies marketed with * are enable as default. When you select “Auto”, the imager only read those symbologies marked with
*
When you set the minimum and maximum length of each symbology, please note the data length of scanned bar code doesn’t include star/sto
p
char
acters
.
Remember to scan “FIN” to terminate
this selection. But if you select the “ Auto
, DelfiScan will terminate this selection
automatically.
Page 16
DelfiScan
Programming Manual
Configure Your DelfiScan
12
PROGR
AM
Symbology Reading Control
Code 39/Code 32 Setting
M_DEF
AULT
Family Code Selection P.C Parameter Selection Option Code
Code 39 Family Setting
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
Disable Code 39 Enable Code 39 Select Standard Code 39 as primary format Select Full ASCII Code 39 as primary format Select Code 32 (PARAF, Italian Pharmaceutical) as primary format Disable start/stop symbol transmission Enable start/stop symbol transmission Disable Code 32 leading A transmission Enable Code 32 leading A transmission Disable MOD 43 check digit verification Enable MOD 43 check digit verification Disable check digit transmission Enable check digit transmission Disable Code 39 buffering Enable Code 39 buffering
0 1 2 3 4 5 6 7 8 9 A B C D E
Trioptic Code 39 Setting
SS SS
Disable Trioptic Code 39 Enable Trioptic Code 39
0 1
Code 39 Min. Length
SS
MS
Default (01) 01-Maximum
Scan 2 digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically.
FIN
(2 digits)
Code 39 Max. Length
SS
MS
Default (98) 98-Minimum
Scan 2 digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically.
FIN
(2 digits)
Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneo
usly.
Page 17
DelfiScan
Programming Manual
Configure Your DelfiScan
13
PROGR
AM
Symbology Reading Control
Codabar/NW-7 Setting
M_DEF
AULT
Family Code Selection P.C Parameter Selection Option Code
Codabar Setting
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
Disable Codabar Enable Codabar Select Codabar standard format Select Codabar ABC format Select Codabar CLSI format Select Codabar CX format Disable start/stop symbol transmission Enable ABCD/ABCD start/stop symbol transmission Enable abcd/abcd start/stop symbol transmission Enable ABCD/TN*E start/stop symbol transmission Enable abcd/tn*e start/stop symbol transmission Disable check digit verification Enable check digit verification Disable check digit transmission Enable check digit transmission
0 1 2 3 4 5 6 7 8 9 A B C D E
Codabar Min. Length
SS
MS
Default (04) 01-Maximum
Scan 2 digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically.
FIN
(2 digits)
Codabar Max. Length
SS
MS
Default (98) 98-Minimum
Scan 2 digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically.
FIN
(2 digits)
Page 18
DelfiScan
Programming Manual
Configure Your DelfiScan
14
PROGR
AM
Symbology Reading Control
UPC-A & UPC-E Setting
M_DEF
AULT
Family Code Selection P.C Parameter Selection Option Code
UPC Family Setting
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
Disable UPC-A Enable UPC-A Disable UPC-E Enable UPC-E Disable UPC-E expansion Enable UPC-E expansion Disable UPC standardization Enable UPC standardization Disable UPC numeric system Enable UPC numeric system Disable UPC-A check digit transmission Enable UPC-A check digit transmission Disable UPC-E check digit transmission Enable UPC-E check digit transmission Disable UPC “leading 1” portion Enable UPC “leading 1” portion
0 1 2 3 4 5 6 7 8 9 A B C D E F
Page 19
DelfiScan
Programming Manual
Configure Your DelfiScan
15
PROGRAM
Symbology Reading Control
UPC-A & UPC-E Setting
M_DEFAULT
Family Code Selection P.C Parameter Selection Option Code
UPC Supplement Setting
SS SS SS SS SS SS SS SS
Select UPC without supplement digits Select UPC with only 2 supplement digits Select UPC with only 5 supplement digits Select UPC with 2/5 supplement digits Disable force supplement digits output Enable force supplement digits output UPC Family Addenda Separator Off UPC Family Addenda Separator On
0 1 2 3 4 5 6 7
UPC-E & EAN-8 Expansion
: Expand the 7-digit UPC-E and 8-digit ENA-8 to 12-digit UPC-A and 13-digit EAN-13.
UPC-A/E Standardization
: Expand the 7-digit UPC-E and 12-digit UPC-A to 8-digit EAN-8 to 13-digit EAN-13 with 1 zero insertion.
UPC Lead 1 Numeric System :
Enable to read UPC leading with the 1 numeric system, you must enable this option.
WPC Selection
(UPC/EAN/CAN)
Basic Length
Disable
Check Digit
Disable
Numeric System
With 2-digit
Addendum
With 5-digit
Addendum
Enable
Standardization
Enable
Expansion
UPC-A 12 -1 -1 + 2 + 5 + 1 0 UPC-E 7 - 1 - 1 + 2 + 5 + 1 + 5 EAN-13 13 - 1 NC + 2 + 5 NC 0 EAN-8 8 - 1 NC + 2 + 5 NC + 5
Page 20
DelfiScan
Programming Manual
Configure Your DelfiScan
16
PROGRAM
Symbology Reading Control
EAN Setting
M_DEFAULT
Family Code Selection P.C Parameter Selection Option Code
EAN Setting
SS SS SS SS SS SS SS SS SS SS SS SS
Disable EAN-13 Enable EAN-13 Disable EAN-8 Enable EAN-8 Disable EAN-8 expansion Enable EAN-8 expansion Disable EAN-13 check digit transmission Enable EAN-13 check digit transmission Disable EAN-8 check digit transmission Enable EAN-8 check digit transmission Disable ISBN/ISSN Conversion reading check Enable ISBN/ISSN Conversion reading check
0 1 2 3 4 5 6 7 8 9 A B
EAN Supplement Setting
SS SS SS SS SS SS SS SS
Select EAN without supplement digits Select EAN with only 2 supplement digits Select EAN with only 5 supplement digits Select EAN with 2/5 supplement digits Disable force supplement digits output Enable force supplement digits output EAN Addenda Separator Off EAN Addenda Separator On
0 1 2 3 4 5 6 7
Page 21
DelfiScan
Programming Manual
Configure Your DelfiScan
17
PROGR
AM
Symbology Reading Control
UCC Coupon Extended Code Setting
M_DEF
AULT
Family Code Selection P.C Parameter Selection Option Code
UCC Coupon Extended Code
SS SS
Disable UCC Coupon Extended Code Enable UCC Coupon Extended Code
0 1
UCC Coupon Extended Co
de
When enabled
, this parameter decodes UPC-A barcodes starting with digit “5”, EAN-13 barcodes starting with digit “99”, and UCC/EAN-128 Co
upon
Codes
. UPC-A, EAN-13 and EAN-128 must be enabled to scan all types of Coupon Codes.
Page 22
DelfiScan
Programming Manual
Configure Your DelfiScan
18
PROGR
AM
Symbology Reading Control
IATA & Interleaved 2 of 5 Setting
M_DEF
AULT
Family Code Selection P.C Parameter Selection Option Code
IATA Setting
SS SS SS SS SS SS SS SS SS SS SS SS SS
Disable IATA Enable IATA Select 15-digit fixed length IATA checking Select variable length IATA Disable check digit verification Enable check digit automatic verification Enable S/N checking digit verification only Enable CPN checking digit verification only Enable CPN, Airline and S/N check digit verification Disable check digit transmission Enable check digit transmission Disable start/stop symbol transmission Enable start/stop symbol transmission
0 1 2 3 4 5 6 7 8 9 A B C
Interleaved 2 of 5 Setting
SS SS SS SS SS SS SS SS SS
Disable Interleaved 2 of 5 Enable Interleaved 2 of 5 Select Interleaved 2 of 5 as primary format Select German Postal Code as primary format No check character Validate USS check digit Validate OPCC check digit Disable check digit transmission Enable check digit transmission
0 1 2 3 4 5 6 7 8
Page 23
DelfiScan
Programming Manual
Configure Your DelfiScan
19
PROGR
AM
Symbology Reading Control
Code 25 Family Setting
M_DEF
AULT
Family Code Selection P.C Parameter Selection Option Code
Code 25 Setting
SS SS SS SS SS SS SS SS SS SS
Disable Standard/Industrial 2 of 5 Enable Standard/Industrial 2 of 5 Disable Matrix 2 of 5 Enable Matrix 2 of 5 Disable China Postal Code Enable China Postal Code Disable check digit verification Enable check digit verification Disable check digit transmission Enable check digit transmission
0 1 2 3 4 5 6 7 8 9
Code 25 Family Min. Length
SS
MS
Default (04) 01-Maximum
Scan 2 digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically.
FIN
(2 digits)
Code 25 Family Max. Length
SS
MS
Default (98) 98-Minimum
Scan 2 digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically.
FIN
(2 digits)
We recommend that you select
only one
kind of Code 25 for reading, or set limited
maximum and minimum reading length
for reading, beca
use
the e
ncoding algorithm of Code 25 isn’t very good. To decode all Code 25 automatically or to read variable length Code 25 will increase the error
reading rate.
Page 24
DelfiScan
Programming Manual
Configure Your DelfiScan
20
PROGRAM
Symbology Reading Control
Code 11 & Code 93 Setting
M_DEFAULT
Family Code Selection P.C Parameter Selection Option Code
Code 11 Setting
SS SS SS SS SS SS SS
Disable Code 11 Enable Code 11 Disable check digit verification Select 1-check digit verification Select 2-check digit verification Disable check digit transmission Enable check digit transmission
0 1 2 3 4 5 6
Code 11 Min. Length
SS
MS
Default (04) 01-Maximum
Scan 2 digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically.
FIN
(2 digits)
Code 11 Max. Length
SS
MS
Default (98) 98-Minimum
Scan 2 digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically.
FIN
(2 digits)
Code 93 Setting
SS SS SS SS
Disable Code 93 Enable Code 93 Disable check digit transmission Enable check digit transmission
0 1 2 3
Code 93 Min. Length
SS
MS
Default (01) 01-Maximum
Scan 2 digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically.
FIN
(2 digits)
Code 93 Max. Length
SS
MS
Default (98) 98-Minimum
Scan 2 digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically.
FIN
(2 digits)
Page 25
DelfiScan
Programming Manual
Configure Your DelfiScan
21
PROGR
AM
Symbology Reading Control
MSI/Plessey Setting
M_DEF
AULT
Family Code Selection P.C Parameter Selection Option Code
MSI/Plessey Setting
SS SS SS SS SS SS SS
Disable MSI/Plessy Enable MSI/Plessy Select MOD 10 check digit Select MOD 10-10 check digit Select MOD 11-10 check digit Disable check digit transmission Enable check digit transmission
0 1 2 3 4 5 6
MSI/Plessey Min. Length
SS
MS
Default (04) 01-Maximum
Scan 2 digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically.
FIN
(2 digits)
MSI/Plessey Max. Length
SS
MS
Default (98) 98-Minimum
Scan 2 digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically.
FIN
(2 digits)
Page 26
DelfiScan
Programming Manual
Configure Your DelfiScan
22
PROGRAM
Symbology Reading Control
Code 128 & UCC/EAN 128 Setting
M_DEFAULT
Family Code Selection
P.C
Parameter Selection Option Code
Code 128/EAN-128 Setting
SS SS SS SS SS SS
Disable Code 128 and UCC/EAN-128 Enable Code 128 and UCC/EAN-128 Disable function code conversion Enable function code conversion ISBT Concatenation Off ISBT Concatenation On
0 1 2 3 4 5
Code 128/EAN-128 Min.
Length
SS
MS
Default (01) 01-Maximum
Scan 2 digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically.
FIN
(2 digits)
Code 128/EAN-128 Max.
Length
SS
MS
Default (98) 98-Minimum
Scan 2 digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically.
FIN
(2 digits)
Page 27
DelfiScan
Programming Manual
Configure Your DelfiScan
23
PROGR
AM
Symbology Reading Control
UK/Plessey Setting
M_DEF
AULT
Family Code Selection
P.C
Parameter Selection Option Code
UK/Plessey Setting
SS SS SS SS SS SS SS SS
Disable UK/Plessey Enable UK/Plessey Select UK/Plessey Standard Format Select UK/Plessey CLSI Format Disable Convert X to A-F Enable Convert X to A-F Disable check digit transmission Enable check digit transmission
0 1 2 3 4 5 6 7
UK/Plessey Min. Length
SS
MS
Default (04) 01-Maximum
Scan 2 digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically.
FIN
(2 digits)
UK/Plessey Max. Length
SS
MS
Default (98) 98-Minimum
Scan 2 digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically.
FIN
(2 digits)
Page 28
DelfiScan
Programming Manual
Configure Your DelfiScan
24
PROGR
AM
Symbology Reading Control
Telepen Setting
M_DEF
AULT
Family Code Selection P.C Parameter Selection Option Code
Telepen Setting
SS SS SS SS SS SS
Disable Telepen Enable Telepen Select Telepen Numeric mode Select Telepen Full ASCII mode Disable check digit transmission Enable check digit transmission
0 1 2 3 4 5
Telepen Min. Length
SS
MS
Default (04) 01-Maximum
Scan 2 digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically.
FIN
(2 digits)
Telepen Max. Length
SS
MS
Default (98) 98-Minimum
Scan 2 digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically.
FIN
(2 digits)
Page 29
DelfiScan
Programming Manual
Configure Your DelfiScan
25
PROGR
AM
Symbology Reading Control
GS1 DataBar Setting
M_DEF
AULT
Family Code Selection P.C Parameter Selection Option Code
GS1 DataBar Setting
SS SS SS SS SS SS
Disable GS1 DataBar (RSS-14) Enable GS1 DataBar (RSS-14) Disable GS1 DataBar Limited Enable GS1 DataBar Limited Disable GS1 DataBar Expanded Enable GS1 DataBar Expanded
0 1 2 3 4 5
GS1 DataBar Min. Length
SS
MS
Default (04) 01-Maximum
Only available for
Expanded
GS1 Databar.
Scan 2 digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically.
FIN
(2 digits)
GS1 DataBar Max. Length
SS
MS
Default (74) 7
4-Minimum
Only available for
Expanded
GS1 Databar.
Scan 2 digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically.
FIN
(2 digits)
Page 30
DelfiScan
Programming Manual
Configure Your DelfiScan
26
PROGR
AM
Symbology Reading Control
Linear-stacked & Korea Post Code Setting
M_DEF
AULT
Family Code Selection P.C Parameter Selection Option Code
Composite Codes Setting
SS SS SS SS
Disable composite codes Enable composite codes UPC Composite Mode: UPC never linked UPC Composite Mode: UPC always linked
0 1 2 3
PDF417/MicroPDF417 Setting
SS SS SS SS
Disable PDF417 Enable PDF417 Disable MicroPDF417 Enable MicroPDF417
0 1 2 3
Codablock F Setting
SS SS
Disable Enable
0 1
Korea Post Code Setting
SS SS
Disable Enable
Length fixed in 6 characters.
0 1
Composite Codes Setting If UPC Composite Mode: UPC never linked is selected, UPC barcodes are transmitted regardless of whether a MicroPDF417 symbol is detected
.
If UPC C
omposite Mode: UPC always linked is selected, UPC barcodes are only transmitted when the MicroPDF417 is detected.
Page 31
DelfiScan
Programming Manual
Configure Your DelfiScan
27
PROGR
AM
Keyboard Interface Control
Keyboard Layout (Language) Setting
M_DEF
AULT
Family Code Selection P.C Parameter Selection Option Code
Keyboard Layout
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
USA (QWERTY) France (AZERTY) Germany (QWERTZ) United Kingdom - UK (QWERTY) Canadian French (QWERTY) Spain (QWERTY) Sweden/Finland (QWERTY) Portugal (QWERTY) Norway (QWERTY) Latin America (QWERTY) Italy (QWERTY) Netherlands (QWERTY) Denmark (QWERTY) Belgium (AZERTY) Switzerland-Germany (QWERTY) Iceland (QWERTY) Japan (DOS/V) Universal * (see note)
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 99
The “
Universal Selection
” is only for PC/AT, PS/VP, PS/2 and compatible ones in
DOS
or
Windows
environment which can perform uniq
ue output
without
C
aps Lock on/off (Output Style) concern. All transmitted data will follow the original full ASCII form. You also need not worr
y about the
upper/lower case control.
Please refer to the
ASC
II/HEX Table
listed in the Appendix to determine HEX codes for characters, symbols, and functions to be used as premble or
postamble.
To set preamble or postambl
e as function key output, you must enable the
“Function Key Emulation”
feature as listed in page 3-25 first.
Keyboard Interface Message String :
Preamble Data Length Prefix Symbol ID
Scanned Data
Suffix Symbol ID Postamble Record Suffix
1-15 characters 2-3 digits 1 or 2 characters Variable length 1 or 2 characters 1-15 characters 1 character
Page 32
DelfiScan
Programming Manual
Configure Your DelfiScan
28
PROGR
AM
Keyboard Interface Control
Record Suffix, Preamble, Postamble & Caps Lock
M_DEF
AULT
Family Code Selection P.C Parameter Selection Option Code
Record Suffix
SS SS SS SS SS SS
None RETURN TAB SPACE ENTER (Numeric Key Pad) User defined character (1 character)
0 1 2 3 4
5, (00-7F)
Preamble
SS
MS
None 1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.
FIN
[00-7F], [FIN]
Posta mble
SS
MS
None 1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.
FIN
[00-7F], [FIN]
Caps Lock Control
SS SS SS
“Caps Lock Off” State “Caps Lock On” State Auto Detect (PC/AT, PS/2, Keyboard Replacement and DOS/V Machines only)
0 1 2
Caps Lock Release Control
SS SS
“Caps Lock On, Caps Off” “Caps Lock On, Shift Off”
0 1
The function of “
Caps Lock Control
” and “
Key Pad Emulation
” are
only
available for IBM PC/AT, PS/VP, PS/2 series personal computers and
compatible machines. While selecting the other host interfaces, these selections do
n’t perform the above functions for you.
Please c
heck the
actual
Caps Lock state in use while software application is running. If the Caps Lock state is off, select “
Caps Lock Off
” state, th
en
DelfiScan will
perform normal data transmission. If the Caps Lock state is on, select “
Caps Lock On
” state. Select “
Auto Detect
”, DelfiScan will
perform
special transm
ission handshaking without chan
ging the status of Caps Lock switch.
Page 33
DelfiScan
Programming Manual
Configure Your DelfiScan
29
PROGR
AM
Keyboard Interface Control
Delay Setting
M_DEF
AULT
Family Code Selection P.C Parameter Selection Option Code
Intermessage Delay
SS
MS
None 1-99 (x5) msec.
Scan 2 digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically.
FIN
(2 digits)
Intercharacter Delay
SS
MS
None 1-99 (x5) msec.
Scan 2 digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically.
FIN
(2 digits)
Interfunction Delay
SS
MS
None 1-99 (x5) msec.
Scan 2 digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically.
FIN
(2 digits)
Intermessage Delay
is a time delay between messages output by DelfiScan. Increasing this delay will help host applications process the incoming
data on time.
I
ntercharacter Delay
is a time delay between data characters output by DelfiScan. These two parameters are used to synchroni
ze data
communication when
: 1) the data transmission speed is too fast, characters may be skipped; 2) multitasking operation system or host computers in a network may slow down the keyboard handling; 3) various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safety margin when adjusting these two parameters
.
Inter
function Delay
is a time delay between the transmission of each segment of the message string.
Page 34
DelfiScan
Programming Manual
Configure Your DelfiScan
30
PROGR
AM
Keyboard Interface Control
Emulation Setting & Upper/Lower Case Setting
M_DEF
AULT
Family Code Selection P.C Parameter Selection Option Code
Function Key Emulation
SS SS
Enable ASCII 00-31 code as keyboard function code output Ctrl-Output
Refer to Appendix – Keyboard Function Code Table for details.
0 1
Key Pad Emulation
SS SS
Disable key pad emulation Enable numeric output as key pad (Num Lock On) output
0 1
Upper/Lower Case
SS SS SS SS
Normal case (neglect the upper/lower case control) Inverse case (change all characters output to inverse case) Upper case (force all characters output as upper case) Lower case (force all characters output as lower case)
0 1 2 3
Page 35
DelfiScan
Programming Manual
Configure Your DelfiScan
31
PROGR
AM
Serial Interface Control
Record Suffix, Preamble ,Postamble Setting
M_DEF
AULT
Family Code Selection P.C Parameter Selection Option Code
STX/ETX Control
SS SS
Disable STX/ETX transmission Enable STX/ETX transmission
STX/ETX are two characters used to indicate the starting and ending of the total data frame transmitted via serial interface.
0 1
Record Suffix
SS SS SS SS SS SS
MS
None CR (0DH) LF (0AH) CRLF (0D0AH) TAB (09H) SPACE (20H) User defined character (1 character)
0 1 2 3 4 5
6, (00-7F)
Preamble
SS
MS
None 1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.
FIN
[00-7F], [FIN]
Posta mble
SS
MS
None 1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.
FIN
[00-7F], [FIN]
Serial Interface Message String (RS232, USB COM) :
STX Preamble Data Length Prefix Symbol ID
Scanned Data
Suffix Symbol ID Postamble ETX Record Suffix
1 character
1-15 characters 2-3 digits 1 or 2 characters Variable length 1 or 2 characters 1-15 characters 1 character 1 character
Page 36
DelfiScan
Programming Manual
Configure Your DelfiScan
32
PROGR
AM
Serial Interface Control
Delay Setting
M_DEF
AULT
Family Code Selection P.C Parameter Selection Option Code
Intermessage Delay
SS
MS
None 1-99 (x5) msec.
Scan 2 digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically.
FIN
(2 digits)
Intercharacter Delay
SS
MS
None 1-99 (x5) msec.
Scan 2 digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically.
FIN
(2 digits)
Interfunction Delay
SS
MS
None 1-99 (x5) msec.
Scan 2 digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically.
FIN
(2 digits)
Intermessage Delay
is a time delay between messages output by DelfiScan. Increasing this delay will help host applications process the
incoming
data on time.
I
ntercharacter Delay
is a time delay between data characters output by DelfiScan. These two parameters are used to synchroni
ze data
communication when
: 1) the data transmission speed is too fast, characters may be skipped; 2) multitasking operation system or host computers in a network may slow down the keyboard handling; 3) various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safety margin when adjusting these two parameters
.
Inter
function Delay
is a time delay between the transmission of each se
gment of the message string.
Page 37
DelfiScan
Programming Manual
Configure Your DelfiScan
33
PROGR
AM
Serial Interface Control
Protocol, Baud Rate, Data Frame & Time Out Setting
M_DEF
AULT
Family Code Selection P.C Parameter Selection Option Code
Handshaking Protocol
SS SS SS SS
None (free running mode) RTS/CTS (hardware handshaking) ACK/NAK (software handshaking) Xon/Xoff (software handshaking)
0 1 2 3
Baud Rate (BPS)
SS SS SS SS
38.4K BPS
19.2K BPS 9600 BPS 4800 BPS
2400 BPS 1200 BPS 600 BPS 300 BPS
0 1 2 3
4 5 6 7
Data Frame
SS SS SS SS SS SS SS SS
8, None, 1 8, Odd, 1 8, Even, 1 8, Space, 1 8, Mark, 1 8, None, 2 7, Odd, 1 7, Even, 1
7, Space, 1 7, Mark, 1 7, None, 2 7, Odd, 2 7, Even, 2 7, Space, 2 7, Mark, 2
0 1 2 3 4 5 6 7
8 9 A B C
D
E
Time Out Control
SS SS SS
MS
None 200 mseconds 500 mseconds
1 second 2 seconds 5 seconds User defined value (seconds)
0 1 2
3 4 5
6, (2 digits)
When the
RTS/CTS Hardware Handshaking
option is selected, the
RTS
(request to send) and
CTS
(clear to send) signals will be is
sued before normal
data communication. T
his option is very helpful to ensure
the reliability of data communication.
When the
AC
K/NAK Software Handshaking
option is selected, the DelfiScan waits for an
ACK
(acknowledge) or
NAK
(not acknowledge) from th
e
host com
puter after each data transmission. If the NAK is received, DelfiScan will re-send the data until receiving AC
K.
The
Tim
e Out Control
is a pre-defined delay time for DelfiScan to wait for handshaking, acknowledgment or non-acknowledgment from
the host
comput
er.
Page 38
DelfiScan
Programming Manual
Configure Your DelfiScan
34
PROGR
AM
Wand/Laser Emulation Control
Output Polarity, Signal State, Margin/Module Time, etc.
M_DEF
AULT
Family Code Selection P.C Parameter Selection Option Code
Output Polarity
SS SS
High level (5Vdc) on Bar (low level on Space) Low level (0Vdc) on Bar (high level on Space)
Determine the output voltage level for both bar and space.
0 1
Initial Signal State
SS SS
High Level (5Vdc) Low Level (0Vdc)
Determine the initial state of output voltage level.
0 1
Margin Time
SS SS SS SS
10 msec. 15 msec. 20 msec. 25 msec.
30 msec. 50 msec. 100 msec. Delay time before data
0 1 2 3
4 5 6
Module Time
SS SS SS
Extremely short Short Medium
Long
Time base of minimum narrow bar
0 1 2
3
Narrow/Wide Ratio
SS SS SS
1:2 1:2.5 1:3
0 1 2
Code 39/Code 128 Emulation
SS SS SS SS SS
Disable standard Cod
e 39 emulation Enable standard Code 39 skip emulation Enable standard Code 39 replace emulation Enable Full ASCII Code 39 emulation Enable Code 128 emulation
0 1 2 3 4
[ Code 39 Skip ]
: When this option is selected, all scanned data will be translated as Standard Code 39 wand/laser emulation output. If any lower case characters are
read, they will be translated to upper case characters. Any other characters that are not available in Code 39 symbology set will be
skipped
.
[ Code 39 Replace]
: Any character not normally available in the standard Code 39 symbology set, will be translated as
Space.
Page 39
DelfiScan
Programming Manual
Configure Your DelfiScan
35
PROGR
AM
Operation Control
Operation Mode Setting
M_DEF
AULT
Family Code Selection P.C Parameter Selection Option Code
Operation Mode
SS SS SS SS SS
Low Power mode Trigger mode/Serial mode Presentation mode Alternative mode Flash mode
Force mode Toggle mode Diagnostic mode Level mode
0 1 2 3 4
5 6 7 8
Presentation Scanning Mode
SS SS SS
Pres
entation mode Flash mode Force mode
0 1 2
Lower Power Mode (Low Power Triggering)
The scanner goes into idle state after scanning the bar code. You must press the trigger to wake up the
scanner for operation. It is very helpful for mobile data collection and application, which are concerned with power savings.
Trigger Mode/Serial Mode (External Triggering)
The scanner goes into standby state after scanning the bar code. You must
press the trigger to
turn on the light source of the sca
nner before scanning the bar code.
Presentation Mode (Auto Detection)
Presentation mode uses ambient light to detect bar codes. The LEDs are off for ambient conditions until
a
change o
ccurs in the imager’s field of view. Then the LEDs turn on automatically to read the bar code. If the light level in the room is not high enough
,
Pres
entation Mode may not work properly.
Alternative Mode (Periodic Power Off)
The scanner keeps the light source of the scanner turned on and disables the infrared sensor till the pre-defined auto power off duration is up. After the scanner turns off the light source, you must press the trigger to turn on the light source again. After each good read, the auto power off timer counter is reset. You do not have to press the trigger frequently, it is very convenient for
multiple
scanni
ng.
Flash Mode (Pulse Driven Reading)
The scanner flashes the light source of the scanner without using the trigger. If the scanner detects an imag
e
which is similar to a bar cod
e, the scanner forces on the light source automatically and scans the bar code. Flash Duty Cycle adjustment can
change
the fr
equency of the blinking.
Force Mode (Continued Power On)
The light source of the scanner is forced on for continued operation without pressing the trigger switch. This
mode is convenient for high speed bar code reading.
Toggle Mode (Repeat Reading)
The toggle mode is very similar to the Alternative Mode without the pre-defined auto power off duration concern.
You must press the trigger to turn on the light source of the scanner to scan. The scanner keeps the light source turned on until
you press the trigger
again.
Diagnostic M
ode (Test Reading)
This operation mode is specifically designed for diagnostic purposes. When this operation mode is selected, the
light source of the scanner is force on without regard for other programmable parameters, such as reread delay, redundancy, and so forth.
Level Mode (Auto Power Off)
When this operation mode is selected, the scanner continues to turn on the light source of the scanner before a good
read or pre-defined auto power off duration. If the scanner decodes a bar code successfully, it turns off the light source immedi
ately. After the scanner
turns off the l
ight source, you must press the trigger to turn on the light source again. If there is no scanning operation performed during the
Page 40
DelfiScan
Programming Manual
Configure Your DelfiScan
36
pre-defined auto power off time, the scanner enters the idle state after the pre-defined auto power off duration.
Presentation Scanning Mode
When the scanner is placed on SmartStand, the scanner’s built-in sensor will switch the scanner from ha
nd-held
scanni
ng to presentation scanning automatically. Three presentation scanning modes are available. Your are recommended to use flash mode or
force mode while under insufficient ambient light.
Only
Lower power mode, Trigger mode, Presentation mode
and
Level mode
are available for DelfiScan Laser model.
Page 41
DelfiScan
Programming Manual
Configure Your DelfiScan
37
PROGR
AM
Operation Control
Buzzer, Indicator, Vibrator, Inverse Reading, Dollar Sign
M_DEF
AULT
Family Code Selection P.C Parameter Selection Option Code
Buzzer Tone Adjust
SS SS SS SS SS SS SS
Buzzer tone – mute Buzzer tone – low Buzzer tone – medium Buzzer tone – high Buzzer tone - extremely high Power-on beep No power-on beep
0 1 2 3 4 5 6
Power On Indicator
SS SS
Disable (LED off) LED steady on LED flash
0 1 2
Vibrator Control
SS SS
Disable Enable
Optional function, only available for vibrator model.
0 1
Inverse Reading
SS SS
Disable Enable
0 1
Dollar Sign Control
SS SS SS SS SS
Dollar sign output as “ $ “ Dollar sign output as “¥“ Dollar sign output as “ € “ Dollar sign output as “ £ “ Dollar sign output as “ ¢ “
0 1 2 3 4
Page 42
DelfiScan
Programming Manual
Configure Your DelfiScan
38
PROGR
AM
Operation Control
Flash Duty Cycle, Redundancy, Delay Setting
M_DEF
AULT
Family Code Selection P.C Parameter Selection Option Code
Flash Duty Cycle
SS SS SS SS
1/2 duty cycle 2/3 duty cycle 3/4 duty cycle 4/5 duty cycle
0 1 2 3
Redundancy (Scan Voting)
SS SS SS SS SS SS
None Level 1 Level 2 Level 3 Level 4 Level 5 To prevent potential miss reading.
0 1 2 3 4 5
Reread Delay
SS SS SS SS SS SS
Disable Immediate time out Short time out Medium time out Long time out Force verification
0 1 2 3 4 5
Good Read Delay
SS SS SS SS SS SS SS
None 200 msec. 500 msec. 1 sec.
1.5 sec. 2 sec. 3 sec.
0 1 2 3 4 5 6
The
Flash Duty Cycle
is designed to control the flashing frequency of the light source
.
The
Re
dundancy
is the number of times the same bar code label has to be decoded befo
re it is transmitted.
The
Rerea
d Delay
is designed to inhibit DelfiScan from reading the same bar code label twice in pre-defined short duration. Force Verification
will not
allow reading of the same ba
r code
twice.
This
Good Read
Delay
is the minimum amount of time before the imager can read another bar code.
Page 43
DelfiScan
Programming Manual
Configure Your DelfiScan
39
PROGR
AM
Operation Control
Time-out Setting, Good Read Beep Duration
M_DEF
AULT
Family Code Selection P.C Parameter Selection Option Code
Auto Power Off Duration
SS SS SS SS
Short Medium Long Extremely long
0 1 2 3
Hands Free Time-out
SS SS SS SS
Short Medium Long Extremely long
0 1 2 3
Good Read Duration
SS SS SS SS
Short Medium Long Extremely long
0 1 2 3
Time Delay to Low Power
Mode
SS SS SS SS SS
1 sec 3 secs 5 secs 7 secs 9 secs
0 1 2 3 4
The
Auto Power Off Duration
is a pre-defined power off time out counter for Alternative Mode, Presentati
on Mode and Flash Mode. The scanner
keeps th
e light source on till the pre-defined auto power off duration is up. You can adjust this parameter to meet your own application requ
irement.
The
Presentation Mode, Force Mode and Flash Mode are referred to as “hands free” modes. The hands free mode will be automatically chan
ged to
manual trigger mode if you remove t
he imager from stand. The manual trigger mode will be changed to hands free mode if you place the imag
er back
to stand. You can set the time for imager to remain in manual trigger mode by setting the
Hands Free Time-Out
. Once the time-out value is up (if
ther
e have been no further trigger pulls), the imager reverts to the original hands free
mode.
The
Time Delay to Low Po
wer Mode
sets the time for scanner to enter low power mode after any scanning activity when the scanner is in th
e Low
Pow
er Mode
.
Page 44
DelfiScan
Programming Manual
Configure Your DelfiScan
40
PROGR
AM
Operation Control
SmartStand Power Off & Presentation Auto-sense
M_DEF
AULT
Family Code Selection P.C Parameter Selection Option Code
SmartStand Power Off
Timeout
SS SS SS
3 mins 5 mins 10 mins
Only available for DelfiScan Laser model
0 1 2
Presentation Scanning
Auto-sense
SS SS
Disable Enable
0 1
The SmartStand Power Off Timeout is a pre-defined duration for scanner placed in SmartStand. While the scanner is placed in SmartStand, the scanner’s built-in sensor will switch the scanner from hand-held scanning to presentation scanning and the light source will be forc
ed on
automatically. The light source will be off
when the pre-defined power off duration
is up.
The
Presentation Scanning
Auto-sense
can auto switch the presentation scanning and hand-held scanning by us
ing the SmartStand.
Page 45
DelfiScan
Programming Manual
Configure Your DelfiScan
41
PROGR
AM
Condensed DataWizard
Preamble, Postamble, Data Length & Symbol ID Trans.
M_DEF
AULT
Family Code Selection P.C Parameter Selection Option Code
Preamble
SS
MS
None 1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.
FIN
[00-7F], [FIN]
Posta mble
SS
MS
None 1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.
FIN
[00-7F], [FIN]
Data Length Transmission
SS SS
Disable Enable 2 digits data length transmission
If data length exceeds 99, 3-digit data length will be transmitted.
0 1
Symbology ID Transmission
SS SS SS SS SS SS SS
Disable symbology ID transmission Enable prefix symbology ID transmission Enable suffix symbology ID transmission Enable both prefix and suffix symbology ID transmission Enable prefix AIM symbology ID transmission Enable suffix AIM symbology ID transmission Enable both prefix and suffix AIM symbology ID transmission
0 1 2 3 4 5 6
DataWizard
is the most powerful, Artificial-Intelligence based data editing expert system provided specially for the DelfiScan family bar code reader
s.
Through DataWizard, you ca
n process the scanned data prior the transmissions in many ways as:
Insert, Delete, Match, Verify, Replace, Reorganize
,
and
Repeat Tr
ansmission
. It will help you to arrange the transmission of scanned data to any specific format without software mo
dification.
Due to the
resources used by this system,
Full-feature DataWizard
is only supported by
PowerTool
. Through the PowerTool, all se
ttings and
con
figurations can be done on-screen, under Windows 95/98/NT/2000/XP environment.
A
Condensed Version DataWizard
is provided by each DelfiScan series. Through this menu, the condensed DataWizard can be utilized via bar code
menu readings
with ease.
Please not
e that all “
Character
” input should be referred to the
ASCII/HEX Table
listed in Appendix
to find matched HEX value.
If you have any problem t
o use DataWizard, please refer to following pages for details and consult your local DelfiScan vendor or our web site for an
y
assistance.
Page 46
DelfiScan
Programming Manual
Configure Your DelfiScan
42
PROGRA
M
Condensed DataWizard
Data Formatter Setting
M_DEFA
ULT
Family Code Selection P.C Parameter Selection Option Code 2nd Option Code
Formatter Control
SS
MS MS
Disable Select one bar code symbology Select all bar code symbologies
FIN
(2 digits)
00
automatic termination automatic termination
1st Insertion
SS
DS
Disable Enable
2-digits identified position; max. 3 insertion characters
FIN
(2 digits)
position
[1-3 characters], [FIN]
2nd Insertion
SS
DS
Disable Enable
2-digits identified position; max. 3 insertion characters
FIN
(2 digits)
position
[1-3 characters], [FIN]
3rd Insertion
SS
DS
Disable Enable
2-digits identified position; max. 3 insertion characters
FIN
(2 digits)
position
[1-3 characters], [FIN]
4th Insertion
SS
DS
Disable Enable
2-digits identified position; max. 3 insertion characters
FIN
(2 digits)
position
[1-3 characters], [FIN]
The
Data Formatter
is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select
desired bar code symbologies for formatter control, and provides
Multiple Position Insertion
and
Multiple Character Insertion
(max three
characters) in the identified position.
While the Data Formatter is enabled, it arranges only scanned data without
Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix
Symbolology ID
or
Record Suffix
. All of the above programmable parameters perform the same function depending on your setting.
Regarding the “
Bar Code Selection
” and “
Position Calculation
” of data formatter, please refer to page 46 for details.
Please note that all “
Character
” input should be referred to the
ASCII/HEX Table
listed in Appendix to find matched HEX value.
Page 47
DelfiScan
Programming Manual
Configure Your DelfiScan
43
PROGRA
M
Condensed DataWizard
Data Verifier Setting
M_DEFA
ULT
Family Code Selection P.C Parameter Selection Option Code 2nd Option Code
Verifier Co ntrol
SS
MS MS
Disable Select one bar code symbology Select all bar code symbologies
FIN
(2 digits)
00
automatic termination automatic termination
Identified Data Length
SS
DS
Disable Enable
Determine the identified data length for verification.
FIN
(2 digits)
1st Identified Character
SS
DS
Disable Enable
2-digits checking position; 1 identified character
FIN
(2 digits)
position
[00-7F]
2nd Identified Character
SS
DS
Disable Enable
2-digits checking position; 1 identified character
FIN
(2 digits)
position
[00-7F]
3rd Identified Character
SS
DS
Disable Enable
2-digits checking position; 1 identified character
FIN
(2 digits)
position
[00-7F]
The
Data Verifier
is used to provide advanced verification for error-free scanning and to work as an
Embedded Data Transmitting Filter
.
All data must conform to the
Identified Bar Code Symbologies, Identified Data Length
, and one to three
Identified Characters
in the checking
position. Otherwise, the DelfiScan will not transmit the data to the host computers or terminals, but will instead issue
3 long beeps
for verification
error and
skip
the scanned da
ta.
The Data Verifier checks only scanned data without
Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID
or
Record Suffix
.
Regarding the “
Bar Code Selection
” and “
Position Calculation
” of
Data Verifier
, please refer to page 46 for details.
Please note that all “
Character
” input should be referred to the
ASCII/HEX Table
listed in Appendix to find matched HEX value.
Page 48
DelfiScan
Programming Manual
Configure Your DelfiScan
44
PROGRA
M
Condensed DataWizard
Data Replacer Setting
M_DEFA
ULT
Family Code Selection P.C Parameter Selection Option Code 2nd Option Code
Replacer Control
SS
MS MS
Disable Select one bar code symbology Select all bar code symbologies
FIN
(2 digits)
00
automatic termination automatic termination
1st Replacement
SS
DS
Disable Enable
2-digits identified position; 1 replacement character
FIN
(2 digits)
position
[00-7F]
2nd Replacement
SS
DS
Disable Enable
2-digits identified position; 1 replacement character
FIN
(2 digits)
position
[00-7F]
3rd Replacement
SS
DS
Disable Enable
2-digits identified position; 1 replacement character
FIN
(2 digits)
position
[00-7F]
The
Data Replacer
is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select
desired bar code symbologies for replacer control, and provides
Multiple Position Replcement
in the identified position.
All data must conform to the
Identified Bar Code Symbologies
, and one to three
Identified Characters
in the identified position While the Data
Replacer is enabled, it arranges only scanned data without
Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID
or
Record
Suffix
.
Regarding the “
Bar Code Selection
” and “
Position Calculation
” of Data Replacer, please refer to page 46
for details.
Please note that all “
Character
” input should be referred to the
ASCII/HEX Table
listed in Appendix to find mathced HEX value.
Page 49
DelfiScan
Programming Manual
Configure Your DelfiScan
45
PROGRA
M
Condensed DataWizard
Data Organizer Setting
M_DEFA
ULT
Family Code Selection P.C Parameter Selection Option Code 2nd Option Code
Organizer Control
SS
MS MS
Disable Select one bar code symbology Select all bar code symbologies
FIN
(2 digits)
00
automatic termination automatic termination
1st Organization
SS
DS
Disable Enable
2-digits identified position; Forward/backward data transmission setting
FIN
(2 digits)
position
direction
0 (Forward)
1 (Backward)
2nd Organization
SS
DS
Disable Enable
2-digits identified position; Forward/backward data transmission setting
FIN
(2 digits)
position
direction
0 (Forward)
1 (Backward)
Include/Exclude Control
SS
DS
Transmitted data excluded the data of identified position Transmitted data included the data of identified position
0 1
The
Data Organizer
is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select
desired bar code symbologies for organizer control, and provides maximum two identified positions to send the data
forward
or
backward
. It also
allows you to control the transmitted data
including
or
excluding
the data of identification position. Please refer to the application example listed in
page 37 for de
tails.
While the Data Organizer is enabled, it arranges only scanned data without
Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology
ID
or
Record Suffix
.
Regarding the “
Bar Code Selection
” and “
Position Calculation
” of Data Organizer, please refer to page 46 for details.
Please note that all “
Character
” input should be referred to the
ASCII/HEX Table
.
Page 50
DelfiScan
Programming Manual
Configure Your DelfiScan
46
Select a B
ar Code Symbology
You can select one or all types of bar code symbologies to use Condensed DataWizard for advanced transmission arrangement. If you scan “00” to select all types, the DelfiScan will arrange all incoming data to meet your pre-defined format. If you want to select only one type bar code, please select one of the option code listed below.
Code 128 :
01
UCC/EAN 128 :
31
UPC-A :
02
UPC-A with 2 supple.: 32
UPC-A with 5 supple.: 42
UPC-E :
03
UPC-E with 2 supple.: 33
UPC-E with 5 supple.: 43
EAN-13 :
04
EAN-13 with 2 supple. :
34
EAN-13 with 5 supple. :
44
EAN-8 :
05
EAN-8 with 2 supple :
35
EAN-8 with 5 supple.:
45
Codabar/NW-7 :
06
Code 39 :
07
Code 32 :
37
Trioptic Code 39:
47
Matrix 2 of 5 :
38
Interleaved 2 of 5 : 48
China Postal Code : 58
German Postal Code : 68
Code 93 :
09
Code 11 :
10
MSI/Plessey : 11
UK/Plessey : 12
Telepen :
13
GS1 Data Bar :
14
IATA :
15
Coupon Code :
16
PDF417/MicroPDF417: 22
Codablock: 23
Korea Post Code:
26
Position Calculation
[Data Formatter]
If there is a 5-character input data string, refer to the following to calculate the actual position for insertion:
X X X X X
00 01 02 03 04 05
[Data Verifier, Data Replacer, Data Organizer]
If there is a 11-character data string, please refer to the following to calculate the actual position for identification.
X X X X X X X X X X X
00 01 02 03 04 05 06 07 08 09 10
Application Example
If your bar code label is a 16-digit Interleaved 2 of 5 which includes the information of 6-digit date code, 6-digit serial number and 4-digit unit price, you want the DelfiScan do the following for you without software modification:
Apply only Interleaved 2 of 5 to the cond
ensed
Da
taWizard.
Check bar code is actually with 16-digi
t length.
All
ow bar code output whose date code is leading with “9”.
Three outputs with “TAB”
suffix.
The date cod
e output should skip “9” and replaced it by “A”.
The serial number output should be led with “SN”
.
T
he unit price output should be skipped the first 2 digits
.
Te
st Bar Cod e : 9 8 1 0 2 5
1 2 3 4 5 6 9 8 7 6
Actual Output : A81025[TAB]SN123456[TAB]76[TAB]
Page 51
DelfiScan
Programming Manual
Configure Your DelfiScan
47
Programming Procedure
[Data Verifier]
Scan “Program” to enter the programming mode.
Scan “Verifier Control” and set bar code symbology to “48
(Interleaved 2 of 5).
Scan “Identified Data Length” and set the length to “16”.
Scan “1st Identified Character” and set the identified position
to “00”, then set the identified character to “39” (H e x Code of
9).
[Data Formatter]
Scan “Formatter Control” and set bar code symbology to “48”.
Scan 1st Insertion” and set the identified position to “06”, t he n
inserted characters to “09” (Hex Code o f TA B ) , “ 53” ( H e x Code of S), “4E” (Hex Code of N).
Scan “2nd Insertion” and set the identified position to “12”,
then inserted character to “09”. In the final, you must scan “FIN” (Finish) code to terminate this selection.
Scan “3rd Insertion” and set the identified position to “16”,
then inserted character to “09”. In the final, you must scan “FIN” (Finish) code to terminate this selection.
[Data Replacer]
Scan “Replacer Control” and set bar
code
symbology to
48”.
Scan “1st Replacement” and set the identified position to
00”, then replaced character to “41” (Hex Cod e o f A).
[Data Organizer]
Scan “Organizer Control” and set bar code symbology to “48”.
Scan “1st Organization” and set the identified position to
16”, then set the data transmission to “0” (forward).
Scan “2nd Organization” and set the identified position to
17”, then set the data transmission to “1” (backward).
Scan “END” (Exit) to terminate the programming.
[Important Notice]
Please note that Condensed DataWizard will follow the preset working flow as below:
Verifier Formatter Replacer Organizer
So when you set the identified position in Data Organizer, you must consider the inserted data which you already set via Data Formatter.
Page 52
DelfiScan
Programming Manual
Appendix
48
Symbology ID Table
Each AIM Code Identifier contains the three-character string ]cm where:
] = Flag Character c = Code
Character
m = Modifier Character
Code
Family
Primary Format
Cino ID AIM ID
Code
Family
Primary Format
Cino ID AIM ID
Code
Character
Code
Character
Modified
Character
Code
Character
Code
Character
Modified
Character
UPC
UPC-A
A
E
m
EAN/JAN
EAN/JAN-8
N E
4
UPC-A with 2 supple.
1
EAN/JAN-8 with 2 supple.
1
UPC-A with 5 supple.
2
EAN/JAN-8 with 5 supple.
2
UPC-E
E
m EAN/JAN-13
F E
m
UPC-E with 2 supple.
1
EAN/JAN-13 with 2 supple.
1
UPC-E with 5 supple.
2
EAN/JAN-13 with 5 supple.
2
Example: A UPC-A bar code 012345678950 with 2 supplement 12 is transmitted as ]E0012345678950]E112
Example: A EAN/JAN-8 bar code 49123562 with 5 supplement 12345 is transmitted as ]E449123562]E212345
Codabar Codabar/NW-7 D F m Code 11 Code 11 P H m
Code 25
Standard/Industrial 2 of 5
I S 0 MSI/Plessey MSI/Plessey R M m
Matrix 2 of 5 K X 0 UK/Plessey UK/Plessey S P 0
Interleaved 2 of 5 J I m Telepen Telepen T B m
China Postal Code L X 0
GS1 DataBar
GS1 Databar
X e 0
Compsoite Composite Code
German Postal Code M I 3
Code 39
Code 39 G A m
IATA IATA O R m Code 39 Trioptic W X 0
Code 93 Code 93 H G m Code 32 G A 0
UCC Coupon
UCC Coupon Code Z PDF417 PDF417/Micro PDF417 V L 0
Example : A UPC-A 512345678900 + UCC/EAN-128
Codablock Codablock F Y O 0
81010123451297 bar code is transmitted as]E0512345678900]C181010123451297
Example: A EAN-13 9923456789019 + UCC/EAN-128 81010123451297 bar code is transmitted as ]E09923456789019]C181010123451297
Korea Post Korea Post Code a X 0
Remark: Above examples are given for the transmission of AIM ID.
Page 53
DelfiScan
Programming Manual
Appendix
49
Keyboard Function Code Table
No. ANSI ASCII Key Function No. ANSI ASCII Key Function
00 NUL 00H RESERVED 16 DLE 10H F7
01 SOH 01H CTRL (Left) 17 DC1 11H F8
02 STX 02H ALT (Left) 18 DC2 12H F9
03 ETX 03H SHIFT 19 DC3 13H F10
04 EOT 04H CAPS LOCK 20 DC4 14H F11
05 ENQ 05H NUM LOCK 21 NAK 15H F12
06 ACK 06H ESC 22 SYN 16H INS (Insert) (Edit)
07 BEL 07H F1 23 ETB 17H DEL (Delete) (Edit)
08 BS 08H BACK SPACE 24 CAN 18H HOME (Edit)
09 HT 09H TAB 25 EM 19H END (Edit)
10 LF 0AH F2 26 SUB 1AH PAGE UP (Edit)
11 VT 0BH F3 27 ESC 1BH PAGE DOWN (Edit)
12 FF 0CH F4 28 FS 1CH UP (Edit)
13 CR 0DH ENTER (CR) 29 GS 1DH DOWN (Edit)
14 SO 0EH F5 30 RS 1EH LEFT (Edit)
15 SI 0FH F6 31 US 1FH RIGHT (Edit)
To
emulate the keyboard function key input for user definable parameters, user must configure actual content using the Reserved ASCII 0 – 31 characters, and also Enable the “Function Key Emulation”. Otherwise, the Ctrl output will be done by the scanner. Please refer to the above Keyboard Function Code Table which is for IBM PC/XT/AT, PS/2, PS/VP, COMPAQ PC, HP Vectra PC, Notebook PC, APPLE and PowerMac, and WYSE PC Enhanced or fully compatible machines.
Page 54
DelfiScan
Programming Manual
Appendix
50
ASCII Input Shortcut
To configure the user definable parameters of DelfiScan via programming menu, DelfiScan will ask you to scan your desired ASCII value in HEX form. You have to refer to the “HEX/ASCII
Tab le ” fo r details.
Example:
If you want the scanned data output leading with a Dollar Sign, you have to set the “Preamble” to “$”. The configuration procedure is listed below for reference.
Scan the system command – PROGRAM listed on page
3-24 to enter programming mode.
Scan family code – PREAMBLE to select this family
.
Refer to the Hex/ASCII Table, you will find the HEX value of
$” is 24.
Scan the option code – 2 listed on the fold out back cover.
Scan the option code – 4 listed on the fold out back cover.
Scan the system command – FIN (Finish) to termin
ate
Preamble setting.
Scan the system command – End to exit the programming
mode for normal operation.
HEX/ASCII Reference Table
H
0 1 2 3 4 5 6 7
L
0
NUL DLE SPACE 0 @ P ` p
1
SOH DC1 ! 1 A Q a q
2
STX DC2 " 2 B R b r
3
ETX DC3 # 3 C S c s
4
EOT DC4 $ 4 D T d t
5
ENQ NAK % 5 E U e u
6
ACK SYN & 6 F V f v
7
BEL ETB ' 7 G W g w
8
BS CAN ( 8 H X h x
9
HT EM ) 9 I Y i y
A
LF SUB * : J Z j z
B
VT ESC + ; K [ k {
C
FF FS , < L \ l |
D
CR GS - = M ] m }
E
SO RS . > N ^ n ~
F
SI US / ? O _ o DEL
Example : ASCII “A” HEX “41”; ASCII “a” “61”
: High Byte of HEX Value
: Low Byte of HEX Value
Page 55
DelfiScan
Programming Manual
Appendix
51
Host Interface Quick Set
RS232 Serial
PS/2 (DOS/V) KBW Standard Mode
USB HID Standard Mode
Keyboard Replacement PS/2 (DOS/V) KBW Turbo Mode
USB HID Turbo Mode
USB Com Port Emulation
Page 56
DelfiScan
Programming Manual
Appendix
52
Operation Mode Quick Set
Lo
wer Power (Low power trigger) Force (Continued power on)
Alternative (Periodic power off )
Trigger (External trigger) Toggle (Repeat reading)
Flash (Pulse driven reading)
Presentation (Auto sensing) Diagnostic (Test reading)
Level (Auto power off )
Page 57
DelfiScan
Programming Manual
Appendix
53
Option Codes
0 8
4 C
1 9
5 D
2 A
6 E
3 B
7 F
FIN (Finish)
END (Exit)
Page 58
DelfiScan
Programming Manual
Appendix
54
System Commands
PR
OGRAM
(Enter Programming Mode)
System Information List
(SYSLIST)
Sa
ve User Default
FIN (Finish) Factory Default
(M_DEFAULT)
Us
er Default
END
(Exit Programming Mode)
PowerTool Host Link
Loading...