Dekker DSH 95 R/C, DSH 135 R/C, DSH 105 R/C, DSH 195 R/C, DSH 265 R/C Service Manual

DEKKER
WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS
SERVICE MANUAL
DSH 95 R/C DSH 105 R/C
DSH 135 R/C DSH 195 R/C
DSH 265 R/C
No.TE100409
CONTENTS
1. IMPORTANT NOTICE ···································2
2. TECHNICAL SPECIFICATION ·····················3
3. OPERATION DETAILS·······································4
4. WIRING DIAGRAM ············· 12
5. EXPLOSION VIEW ····························15
6. PARTS LIST ·············20
IMPORTANT NOTICE
This service manual is intended for use by individuals possessing adequate backgrounds of electrical, electronic and mechanical experience. Any attempt to repair the appliance may result in personal injury and property damage. The manufacturer or seller cannot be responsible for the interpretation of this information, nor can it assume any liability in connection with its use.
The information, specifications and parameter are subject to change due to technical modification or improvement without any prior notice. The accurate specifications are presented on the nameplate label.
How to order spare parts
To have your order filled promptly and correctly, please furnish the following information:
1. Model No. with Indoor or Outdoor
2. No. in the Explosion View
3. Part Name
4. The quantity you ordered
TCL Air Conditioner Service ManualTCL Air Conditioner Service ManualTCL Air Conditioner Service Manual
BERG Air Conditioner Service Manual
2
DSH 95 R/C DSH 105 R/C DSH 135 R/C DSH 195 R/C DSH 265 R/C
Heating Pump Heating Pump Heating Pump Heating Pump Heating Pump
Btu/h;W 7000 9000 12000 18000 24000 Btu/h;W 7200
9500 12800 19000 24500
Btu/h.w
8.97 8.94 9.01 9.14 9 W/W 2.89 2.63 2.75 2.75 2.7 Liters/h 0.5 0.8 1 1.5 2.4
High dB(A) 36 36 37 42 49 Med. dB(A) 33 33 34 39 46 Low dB(A) 29 29 32 36 42
dB(A) 50 50 52 58 58
V 198~264 198~264 198~264 198~264 198~264
Cooling A 3.6 4.6 6.0 9.0 13.0 Heating A 3.3 4.8 6.2 9.2 13.8 Cooling W 780 1010 1330 1970 2600 Heating W 730 1060 1360 2020 2800
Gram R22 R22 R22 R22 R22
Compressor Rotary Rotary Rotary Rotary Rotary
m
3
/h
430 430/430 530/530 800/850 1100/1100
Cross flow Cross flow Cross flow Cross flow Cross flow Cooling rpm 1270/1170/1000 1270/1170/1000 1270/1170/1000 1300/1220/1150 1300/1220/1150 Heating rpm 1250/1150/1000 1250/1150/1000 1250/1150/1000 1300/1220/1150 1300/1220/1150 Dry rpm 1000 1000 1000 1150 1150 Sleep rpm 1000 1000 1000 1150/1150 1150
W12 12 12 23 35
Propeller Propeller Propeller Propeller Propeller rpm 895 895 860 850 840 W25 20 31 55 55
Gas Inches Φ9.52(3/8'') Φ9.52(3/8'') Φ12.7(1/2'') Φ12.7(1/2'') Φ15.88(5/8'') Liquid Inches Φ6.35(1/4'') Φ6.35(1/4'') Φ6.35(1/4'') Φ6.35(1/4'') Φ9.52(3/8'')
Connecting Wiring 1.0x3; 0.75x2 1.0x3; 0.75x2 1.0x3; 0.75x2 1.5x3; 0.75x2 4×0.75;2×0.75
m
2
6~10 9~16 15~23 20~35 30~50 Indoor mm 718x240x180 718x240x180 770x240x180 900x280x202 1033x313x202 Outdoor mm 600x500x232 600x500x232 700x552x256 820x605x300 820x605x300 Indoor kg 7 7 8 11 14 Outdoor kg 23 24 30 41 52 Indoor mm 805×305×265 805x305x265 855x305x265 995x365x298 1103x400x300 Outdoor mm 745x542x353 745x542x353 803x598x380 965x650x438 965x650x438 Indoor kg 9 9 10 14 17
Outdoor kg 26 27 34 45 58
3
O.D 16mm
Indoor air circulation(Cooling/Heating)
Defrosting system
Evaporator
Capillary tube
Microcomputer controlled reverse system
Packing dimensions (W x H x D)
Indoor fan motor output Outdoor fan type Outdoor fan speed Outdoor fan motor output
Size x Core number
Drainage Pipe
Technical Specifications
Fan System
Condenser
Refrigerating System
Refrigerant/Charge
Type
Hydrophilic & Louver Fin; Innergroover tube type (φ7)
Louver or Corrugated Fin; Innergroover tube type (φ9.52 or φ7)
Gross weight
Indoor fan type
Indoor fan speed H/M/L
Expansion device
Others
Suitable area Net dimensions
(W x H x D)
Net weight
Connections
Connecting Pipe
Outdoor noise level
Electrical Data
Rated input
Power supply 220-240V~/50Hz/1P Voltage Range
Rated current
Remote Controller
Moisture removal Indoor noise level at
cooling
DEKKER Air Conditioner Service Manual
Model No.
Type
COP for heating
Rated cooling capacity Rated heating capacity EER for cooling
Control type
4
Note: Each mode and relevant function will be further specified in following pages.
SLEEP
FAN
TIMER
SWING
ON/OFF
MODE
MID
SWING
AUTO
DRY FAN HEAT
COOL
FEEL
SLEEP
TIMER ON
HIGH
LOW
TMIER OFF
The remote controller transmits signals to the system.
Remote controller
1
2
4
3
5
6
7
8
8 4
MODE button
FAN SPEED control button
UP button (TOO COOL button)
DOWN button (TOO WARM button)
ON/OFF button
SLEEP button
VANE control button
TIMER button
Used to select the type of operation mode: Feel, Cooling, Dry, Fan and Heating(Only for Heat Pump).
Used to select the indoor fan motor speed: Auto, High, Mid and Low.
Used to increase the set room temperature
and time.
Used to decrease the set room temperature and time.
Used to set or cancel sleep mode operation.
Used to start and stop operation when pressed.
Used to adjust airflow direction.
Used to select TIMER operation.
Remote controller
6
2
5
3
7
1
11
HPC Air Conditioner Service Manual
Operation Details
Remote Control
The remote controller is not presetted as Cooling Only Air Conditioner or Heat Pump by manufacturer. Each time after the remote controller replace batteries or is energized, the arrowhead will flashes on the front of
Heat or Cool on LCD of the remote controller. User can preset the remote controller type depending on the air conditioner type you have purchased as follows: Press any button when the arrowhead flashes on the front of Cool , Cooling Only is set. Press any button when the arrowhead flashes on the front of Heat , Heat Pump is set. If you don t press any button within 10 seconds, the remote controller is preset as Heat Pump automatically.
Note :
If the air conditioner you purchased is a Cooling Only one, but you preset the remote controller as Heat Pump, it doesn t bring any matter. But if the air conditioner you purchased is a Heat Pump one, and you preset the remote controller as Cooling Only, then you CAN NOT preset the Heating operation with the remote controller.
HPC Air Conditioner Service Manual
5
Electronic controller:
1.Automatic mode
1) Initial RT determines the working mode and ST,the mode is determined effective only once unless A/C shut-down then re-started. If from other modes switches to autoamatic mode (including mode conversion after shutdown), it should be that the compress stop more than 3 min then temperature judgement and automatic mode are conducted (it can conduct immediately from fan mode switched to automatic, the indoor fan stops, three minutes later the response is made and start up). Within 3 min, the output as: Showing the room temperature, indoor fans starts (or anti-cold airflow), the outdoor fan stops;
2) With memory controller, once being turned off or in case of an accidently power cut, the A/C is able to retain and restore the original mode when being turned on or the power supply is resumed, if the auto restart function activated. power-down after power-on; while if the auto restart fundction isn’t activated, the A/C enters standby state. Heat pump
Mode Initial RT Initial ST Cooling
RT26 23
Dehumifying
26℃>RT20 18
Heating
RT20 23
Cooling-only
Mode Initial RT Initial ST Cooling
RT26 23
Dehumifying
26℃>RT20 18
Ventilating
RT20 Under automatic mode (including from automatic converted into dehumidifying Dry mode), when the temperature up and down signals from the remote controller is received, the setting temperature ST adjusts correspondingly to the current room temperature plus or minus 1, the automatic regulating temperature range is ± 2℃.
2Cooling mode
1) The control of the compressor a. When RT-ST≥1℃,the compressor is running. b. When RT-ST<-1℃,the compressor is off. c. When -1℃≤RT-ST<1℃, the compressor keeps its original state.
2) Outdoor fan motor and the compressor run simultaneously (except for defrosting).
3) The control of indoor fan motor: a. Indoor fan motor can operate by automatic, low, middle, and high airflow speed circularly. b. Indoor fan motor’s the automatic airflow speed control Indoor fan motor can operate by automatic as shown in Figure 1:
Hi Mid
Lo
RT-ST 1℃ 2℃ 4
Figure 1 Cooling automatic airflow When the temperature changes lead to changes in airflow speed, the switch can only be made orderly, and every grade of air flow speed runs 1 minute at least.
HPC Air Conditioner Service Manual
6
3, Dry mode running into this mode, the Air cond. firstly operates for 3 minutes according to cooling mode (set temperature is 7) , and then takes the detected backflow air temperature minus 2 as a new set temperature (the minimum value of 5) and runs according to cooling mode, indoor fan operates at low-speed, at this moment the setting operation of Fan speed is invalid but Swing is adjustable.
4. Heating mode On the Heating mode, the room temperature is repaired. After repaired, the room temperature display on the LED CRT=RT-3℃.
1) The control of the compressor a. When ST-CRT≥1the compressor is running. b. When ST-CRT<-1,the compressor is off. c. When -1≤ST-CRT<1℃, the compressor keeps its original state
2) Outdoor fan motor and the compressor run simultaneously (except for defrosting)
3) The control of indoor fan motor: a. Indoor fan motor can operate by automatic, low, middle, and high airflow speed circularly. b. indoor fan motor’s the automatic airflow speed control Indoor fan motor can operate by automatic as shown in Figure 2:
Hi Mid
Lo
ST-CRT 1℃ 2℃ 4
Figure 2 Heating automatic airflow When the temperature changes lead to changes in airflow speed, the switch can only be made orderly, and every grade of air flow speed runs 1 minute at least.
4) Vane motor control: run as set state.
5) 4-way valve control: a. Under heating mode, the four-way valve maintains well-connected status (including the compressor stops on set condition, but except for the defrosting process) b. When the mode switches into the heating mode or start-up, four-way valves will open 5 Seconds before the compressor starts; while the mode exits from the heating mode or turn off, the four-way valve will close 2min after after the shut-down the compressor.
6) Defrosting function: During defrosting, once mode switch, temperature setting signals received, and the buzzer and display make response immediately, but the other operations won’t implemented until defrosting finished; During defrosting, the signals of on-off, timing, sleep, airflow speed ans swing will be responded, but the airflow speed and swing should be in accordance with anti-cold air rules. Except the above signal processing during defrosting, no other signals will be dealt with, but only a loud buzz. During d
efrosting, electrical heating stops compulsively. Defrosting enter and exit pragram: Option 1with jumper JC The condition of enter defrosting: run into defrosting once any of condition 1, 2, and 3 met.
HPC Air Conditioner Service Manual
7
Condition 1As shown in figure 3 Defination: The followings are all required to meet: a. IPT1 settles for IPT1=IPTmax-△IPT(8℃) b. t5≥50min(running time t5≥50min(the compressor runs cumulatively),t5 is removable,and could be less than t1 c. IPT<40℃,and lasts 2min Running into defrosting on condition 1, the first running time of set defrosting is F (8min); after running a defrosting cycle, the defrosting time should be determined and adjusted.
Figure 3 Condition 2: When running time is more than or equal to 120 min (compressor is running accumulatively), the indoor temperature is less than 35 ° C for 2 min sustained. Running into defrosting under condition 2, defrosting time set is 8 min. Condition 3: after the compressor is operating for 20min continuously, the indoor temperature is less than 23 ° C which is anti-cold wind temperature when the fan stops running(including temperature droping when compressor operating, not including the compressor’s starting course), and the machine runs into defrosting according to any one condiciton as below) Running into defrosting under condition 3, defrosting time set is 10 min. a) Running into the first defrosting in 20 min after start-up. b) The interval from last defrosting equivalent to or more than 50 min (stopping the compressor or the machine in standby is allowed in the meantime). Option 2: No Jumper JC, and no OPT outdoor sensor when the compressor runs for 45 min, if the indoor coil temperature is less than 40 ° C for 2 min, the machine runs into defrosting, and lasts for 3min, otherwise when the compressor runs for 120 min, the machine runs into defrosting automatically and last for 10 min. Option 3: No jumper JC, but with OPT outdoor sensor When heating, when the temperature of outdoor unit under heat-exchange is lower than E ° C (-4 ° C), and the compressor runs for 45 min, then the machine runs into defrosting and last for 10 min. Option 4. When heating, when the outdoor fan motor stopped but the compressor not stopped
HPC Air Conditioner Service Manual
8
accumulative total 30min, then the machine runs into defrosting and last for 8 min. if the accumulative total less than 30min, but accord with one of the condition option 1-3 them the machine runs into defrosting at the option 1-3 and the accumulative tota time restarts from 0. Conditions for quitting defrostng (1) The quitting conditions for option 1 and option 2, the machine quits from defrosting if any one below condition met. a. Defrosring time is over. b.When it runs in defrosting for three minutes, the IPT indoor coil temperature rises 15 ° C or above from the bottom point. (2) The quitting conditions for option 3. When OPT 20 ° C or defrosting for more than 10 min, then quit from defrosting. (3) Defrosting process shown in Figure 4
Figure 4 Defrosting process
7) Auxiliary Electric heating function (1)The default condition is automatic on/off the electric heating function. (2) The conditions of auxiliary electric heating(all the following conditions must be met) a. the compressor runs for more than 3min b. indoor fan runs normally c. not in defrosting state; d. auxiliary electric heating is turned off for more than 30s e. ST-RT≥3°C; f. RT﹤22°C; g. IPT≤43°C; (3) The conditions of stopping auxiliary electric heating(any one of the following conditions met, the state stops) a. the compressor stops b. RT≥24°C; c. IPT≥48°C d. indoor fan stops e. running into sleeping function
5. Fan mode
1) Indoor fan motor control:
HPC Air Conditioner Service Manual
9
indoor fan motor is running at setting speed (the speed is same as that of heating).
2) Vane motor control: running according to the setting.
3) The outdoor unit is not working under fan mode.
6. Sleeping mode
1) Under sleep mode, the indoor fan motor is running at a low-airflow speedexcept that the power light and sleep light are on, timer light is on/off according to the setting state, running light is off. LED is off after displaying 5min.
2) Temperature control: (1) From cool mode to sleep mode, one hour later, the operates Temp.=ST+1,another one hour later, the operates Temp.=ST+2,after then unchanged. (2) From heating mode to sleep mode, one hour later, the operates Temp.= ST-1,another one hour later, the operates Temp.=ST-2after then unchanged.
3) the machine will automatically shut up after running 8 hours under sleep mode. Timer on start-up and sleep mode are implemented at the same time, and the sleep mode can not be functioned.
7. Timing fuction
The timing scale is between 10min to 24h, when the time fixed is less than “10” hours, the displayed time is shown by 0.5 hour as the unit, when the time fixed is more than or equal to “10” hours, the displayed time is shown by 1 hour as the unit.
8. Emergency switch(ON/OFF)
1) When stand-by, to operate by pressing the emergency switch as follows: To Press the emergency switch in three seconds, the buzzer rings once, and to release, the machine runs into cooling mode; if to holding on, the buzzer rings twince, then the machine runs into heating mode, while when the machine is on, to press the emergency Switch, the buzzer rings once and then the machine shut down.
2) The machine is running mandatorily as the selected mode within 30min after emergency operation, indoor fan motor is running in high-speed, and vane board is swinging. The machine runs into automatic mode 30min later, the selected mode unchanged, the set temperature is 23° C ,the rotate speed of indoor fan motor is automatic, and vane board is swinging too.
3) To press the emergency button when the machine operating, then the machine runs into stand-by state.
4) Under emergency operationthe Compressor’s time-lapse protection, anti-frosting protection in cooling, Overheating protection in heating and sensor fault protection and defrost operate are effective.
5) Under emergency operation, once effective signal from remote controller is received, then the machine exits form the emergency mode, and operate according to the setting from remote controller.
9. Auto-restart function
1) The PCB retains the setting parameters in case of power off. When the power supply is resumed, the machine, which has been started up the power-off memory function, is able to restore into the original running state automatically.
2) To press the emergency button and power on, and hold on 10 seconds, exit from the power-off memory function, buzzer rings four tomes.(default: no this function)
10. Protection/ Troubleshooting functions
HPC Air Conditioner Service Manual
10
1) Compressor’s protection function: aThe PCB which has Power-off memory function, once this function is started up,the compressor goes along 3min delay protection when power on. If the PCB hasn’t been started up this function, even when the PCB is power-on, the compressor doesn’t process 3 min delay function. bCompressor’s 3 min interval protection: the compressor can’t start-up until 3 min later(except for defrosting process). c.After the compressor started, the compressor’s state isn’t subject to the changes on ST,RT in 3min.
2) Anti-frosting protection of indoor evaporator:
If IPT 0 detected in consecutive 5 min, compressor and outdoor motor stoped, indoor fan motor runs at high-speed forcibly; IPT 5 detected 3min later, then outdoor fan is activated. And the compressor, indoor fan motor restores the original state.
3) Overheating protection: IPT ≥ 55℃, the outdoor fan stops, IPT ≥ 65℃, the compressor stops, indoor fan motor runs at high-speed forcibly. When IPT 48, outdoor fan motor and the compressor open, indoor fan motor restores the original state.
4) Anti-cold wind control in heating: a. When runing into the heating mode, once the compressor fails to comply with the start-up conditions, the wind speed is regulated according to the coil temperature in 2 min(including stopping the indoor fan motor), 2 min later the indoor fan motor stops.If the compressor starts up within 2 min, then operating by Figure 5. Under heating process, to close the compressor (including the downtime protection ), the wind speed is regulated according to the coil temperature in 1min(including stopping the indoor fan), 1min later the fan is stoped forcibly. b. When the indoor fan motor running at a low-speed wind and in anti-cold wind operation, once electric heating opens,the vane immediately withdraws from the anti-cold windy location and turn back to normal vane angle. When electric heating closes, indoor fan motor go on to run at low-speed wind, accordingly, the vane turns to anti-cold windy location.
Figure 5 Anti-cold Wind
2) The following table shows the fault protections. When failures happens, the PCB alarms and buzzer rings three times. Failure code appears, and the PCB operates protection procedures.
HPC Air Conditioner Service Manual
11
Failure code: For the machine has LED, the code displays on LED, for no LED machine, the code reflects by the running light.
Failure Running Light Flash LED Display
RT Sensor Failure Once / Period E1
IPT Sensor Failure Twice / Period E2
Indoor Fan Motor Failure 6 times / Period E6 When there is LED displaying failure code, the code is displayed statically, if there are several failure codes should be reported at the same time, then failure codes appears one by one every eight seconds correspondingly. a. Sensor’s failure protection: when the sensor’s temperature is out of the range -50 T 110 ℃, then sensor failue is determined. Once RT, IPT sensor failures appear, the compressor stops and indoor and outdoor fan motors shut off. Remote controller deesn’t response to any signal except for shutdown. During failure the machine can run in fan mode. After the failure is settled, the PCB restores to standby status. b. Failure protection of Indoor PG fan motor:If there is no feedback signal of rotate speed within 5, the indoor fan motor stops,at the same time, the compressor, outdoor fan moto, four-way valve and auxiliary electric heater etc cut downn. 10 seconds later, the indoor fan motor restarts, once there is no feedback signal of rotate speed within 5 seconds either, then the machine stops and goes into indoor fan motor failure protection, buzzer rings three times, and running light flashes at 6 times per 8 seceonds. When the failure is confirmed, once there is feedback signal,the failue is relieved automatic.
HPC Air Conditioner Service Manual
12
WIRING DIAGRAM
MODEL:DSH 95 R/C, DSH 105 R/C, DSH 135 R/C INDOOR UNIT:
OUTDOOR UNIT
HPC Air Conditioner Service Manual
13
WIRING DIAGRAM
MODEL:DSH 195 R/C INDOOR UNIT:
OUTDOOR UNIT
HPC Air Conditioner Service Manual
14
WIRING DIAGRAM
MODEL:DSH 265 R/C INDOOR UNIT:
OUTDOOR UNIT
TCL Air Conditioner Service Manual
15
EXPLOSION VIEW
INDOOR UNIT: MODEL:DSH 95 R/C, DSH 105 R/C, DSH 135 R/C, DSH 195 R/C
15
6
14
11
13
12
8
10
9
7
1
5
4
3
2
19
18
17
16
23
24
21
20
22
26
25
27
TCL Air Conditioner Service Manual
16
EXPLOSION VIEW
INDOOR UNIT: MODEL: DSH 265 R/C
8
13
11
12
10
9
14
4
6
7
5
3
2
1
23
15
17
16
20
18
1
21
22
2
25
24
2
HPC Air Conditioner Service Manual
17
EXPLOSION VIEW
OUTDOOR UNIT: MODEL: DSH 95 R/C
12
13
14
10
11
9
7
6
5
19
15
16
18
17
21
20
22
23
25
24
26
4
3
2
27
1
8
HPC Air Conditioner Service Manual
18
EXPLOSION VIEW
MODEL: DSH 105 R/C, DSH 135 R/C, DSH 195 R/C OUTDOOR UNIT:
11
12
13
9
10
8
7
6
5
18
14
15
17
16
20
19
21
22
24
23
25
4
3
2
26
1
HPC Air Conditioner Service Manual
19
EXPLOSION VIEW
MODEL: DSH 265 R/C OUTDOOR UNIT:
10
11
8
9
6
7
5
4
20
14
12
13
15
16
17
18
19
3
2
21
22
24
23
25
27
1
26
No. Part No. Part Name Q’ty Remark
1 1080030003 Installation Plate 1 2 1210250103 Base 1 3 1070020017 Cross Fan 1 4 1070100010 Bearing Mount 1 5 1210231201 Evaporator 1 6 1070251833 Water Drainage Assembly 1 7 1070321035 Vertical Vane Assembly 2 8 1070251841 Face Frame 1
9 1070320112 Screw Cover 2 10 1070250106 Air Filter 2 11 1070251941 Front Panel 1 12 1170120042 Power Supply Cord 1 13 1070251837 Vane 1 14 1070110011 Drainage Hose 1 15 1070321024 Display PCB Cover 1 16 1090320291 Display PCB(Digital) 1 17 1070321181 Display PCB Box 1 18 1070040004 Cable Clamp 1 19 1170020011 Vane Motor 1 20 1090250016 Main PCB(Digital) 1 21 1073030201 Sensor Holder 1 22 1070320113 Electrical Box 1 23 1070320111 Indoor Motor Cover 1 24 1170030047 Indoor Motor 1 25 1170240001 Transformer 1 26 1170230001 Indoor Sensor Assembly 1 27 1070320101 In And Out Pipe Fixer 1 29 1090050649 Remote Controller 1 29 1070060003 Remote Controller Supporter 1 30 1190250885 Indoor Carton 1 31 1191990102 Left Foaming 1 32 1191990103 Right Foaming 1
Not shown in Explosion view
20
TCL Air Conditioner Service Manual
Indoor Unit- DSH 95 R/C
No. Part No. Part Name Q’ty Remark
1 1080030003 Installation Plate 1
2 1210250103 Base 1
3 1070020017 Cross Fan 1
4 1070100010 Bearing Mount 1
5 1210231201 Evaporator 1
6 1070251833 Water Drainage Assembly 1
7 1070321035 Vertical Vane Assembly 2
8 1070251841 Face Frame 1
9 1070320112 Screw Cover 2 10 1070250106 Air Filter 2 11 1070251941 Front Panel 1 12 1170120042 Power Supply Cord 1 13 1070251837 Vane 1 14 1070110011 Drainage Hose 1 15 1070321024 Display PCB Cover 1 16 1090320291 Display PCB(Digital) 1 17 1070321181 Display PCB Box 1 18 1070040004 Cable Clamp 1 19 1170020011 Vane Motor 1 20 1090250016 Main PCB(Digital) 1 21 1073030201 Sensor Holder 1 22 1070320113 Electrical Box 1 23 1070320111 Indoor Motor Cover 1 24 1170030047 Indoor Motor 1 25 1170240001 Transformer 1 26 1170230001 Indoor Sensor Assembly 1 27 1070320101 In And Out Pipe Fixer 1 29 1090050649 Remote Controller 1 29 1070060003 Remote Controller Supporter 1 30 1190250885 Indoor Carton 1 31 1191990102 Left Foaming 1 32 1191990103 Right Foaming 1
Not shown in Explosion view
21
TCL Air Conditioner Service Manual
Indoor Unit- DSH 105 R/C
No. Part No. Part Name Q’ty Remark
1 1080030008 Installation Plate 1 2 1210320107 Base 1 3 1070020026 Cross Fan 1 4 1070100010 Bearing Mount 1 5 1210320601 Evaporator 1 6 1070321032 Water Drainage Assembly 1 7 1070321035 Vertical Vane Assembly 2 8 1070321030 Face Frame 1
9 1070320112 Screw Cover 2 10 1070250106 Air Filter 2 11 1070322132 Front Panel 1 12 1170120045 Power Supply Cord 1 13 1070321034 Vane 1 14 1070110011 Drainage Hose 1 15 1070321024 Display PCB Cover 1 16 1090320291 Display PCB(Digital) 1 17 1070321181 Display PCB Box 1 18 1070320114 Cable Clamp 1 19 1300321241 Main PCB(Digital) 1 20 1070320113 Electrical Box 1 21 1170020011 Vane Motor 1 22 1073030201 Sensor Holder 1 23 1170030047 Indoor Motor 1 24 1070320111 Indoor Motor Cover 1 25 1170240001 Transformer 1 26 1170230001 Indoor Sensor Assembly 1 27 1070320101 In And Out Pipe Fixer 1 28 1090050649 Remote Controller 1 29 1070060003 Remote Controller Supporter 1 30 1190320879 Indoor Carton 1 31 1191990102 Left Foaming 1 32 1191990103 Right Foaming 1
TCL Air Conditioner Service Manual
22
Not shown in Explosion view
Indoor Unit- DSH 135 R/C
No. Part No. Part Name Q’ty Remark
1 1080030003 Installation Plate 1 2 1210250103 Base 1 3 1070020017 Cross Fan 1 4 1070100010 Bearing Mount 1 5 1210231201 Evaporator 1 6 1070251833 Water Drainage Assembly 1 7 1070321035 Vertical Vane Assembly 2 8 1070251841 Face Frame 1
9 1070320112 Screw Cover 2 10 1070250106 Air Filter 2 11 1070251941 Front Panel 1 12 1170120042 Power Supply Cord 1 13 1070251837 Vane 1 14 1070110011 Drainage Hose 1 15 1070321024 Display PCB Cover 1 16 1090320291 Display PCB(Digital) 1 17 1070321181 Display PCB Box 1 18 1070040004 Cable Clamp 1 19 1170020011 Vane Motor 1 20 1090250016 Main PCB(Digital) 1 21 1073030201 Sensor Holder 1 22 1070320113 Electrical Box 1 23 1070320111 Indoor Motor Cover 1 24 1170030047 Indoor Motor 1 25 1170240001 Transformer 1 26 1170230001 Indoor Sensor Assembly 1 27 1070320101 In And Out Pipe Fixer 1 29 1090050649 Remote Controller 1 29 1070060003 Remote Controller Supporter 1 30 1190250885 Indoor Carton 1 31 1191990102 Left Foaming 1 32 1191990103 Right Foaming 1
Not shown in Explosion view
23
TCL Air Conditioner Service Manual
Indoor Unit- DSH 105 R/C
Part List
No. Part No. Part Name Q’ty Remark
1 1080030001 Installation Plate 1 2 1070701047 Base 1 3 1070020014 Cross Fan 1 4 1070100010 Bearing Mount 1 5 1110050321 Evaporator 1 6 1070701048 Water Drainage Assembly 1
1070701050 Vertical Vane Assembly A 1
1070701051 Vertical Vane Assembly B 1 8 1070701060 Face Frame 1 9 1073090111 Screw Cover 3
1073090112 Left Air Filter 1
1073090113 Right Air Filter 1
11 1070701284 Front Panel 1 12 1070700511 Display PCB Cover 1 13 1300700890 Display PCB(Digital) 1 14 1073090114 Electrical Box Cover 1 15 1070701052 Vane A 1 16 1070701053 Vane B 1 17 1070110011 Drainage Hose 1 18 1074060118 Cable Clamp 1 19 1170020041 Vane Motor 2 20 1090700403 Main PCB(Digital) 1 21 1073030201 Sensor Holder 1 22 1073090121 Electrical Box 1 23 1073090120 Indoor Motor Cover 1 24 1170030048 Indoor Motor 1 25 1173090107 Transformer 1 26 1170230001 Indoor Sensor Assembly 1 27 1090050649 Remote Controller 1 28 1070060003 Remote Controller Supporter 1 29 1190500155 Indoor Carton 1 30 1150700001 Left Foaming 1 31 1150700002 Right Foaming 1 32 1190060021 Middle Pasteboard Supporter 1 33 1190060021 Middle Foaming Supporter 1
TCL Air Conditioner Service Manual
24
Indoor Unit- DSH 265 R/C
Not shown in Explosion view
10
7
Part List
No. Part No. Part Name Q’ty Remark
1 1083510901 Grille 1
Optional
2 1081990014 Top Cover 1 3 1110061174 Condenser 1 4 1081990018 Outdoor Motor Supporter 1 5 1170040062 Outdoor Motor 1 6 1070030006 Propeller Fan 1 7 1081990011 Left Grille Supporter 1 8 1080320147 Left airproof plate 1
9 1081990016 Front Plate 1 10 1071990044 Fan Guard 1 11 1100060199 Compressor And It Accessories 1 12 1120110002 4-way Valve 1 13 1120200477 4-way Valve Assembly 1 14 1091990046 Base 1 15 1081990012 Right Plate 1 16 1120120008 Two-way Valve 1 17 1081990013 Valve Supporter 1 18 1120130011 Three-way Valve 1 19
1073521301
Electrical Box Cover 1
20 1070040001
Cable Clamp(φ6)
1
21 1070040002
Cable Clamp(φ7)
1 22 1170500131 Terminal 1 23 1170100031 Fan Motor Capacitor 1 24 1170100014 Compressor Capacitor 1 25 1080010006 Capacitor Strip 1 26 1080020001 Electrical Parts Box 1 27 1120200476 Capillary Assembly 1 28 1190070014 Base Carton 1 29 1190200313 Cabinet Carton 1 30 1190070016 Base Foaming 1 31 1190070015 Cover Forming 1
25
Not shown in the Explosion view.
Outdoor Unit- DSH 95 R/C
HPC Air Conditioner Service Manual
Part List
No. Part No. Part Name Q’ty Remark
1 1071990038 Grille 1
Optional
2 1081990014 Top Cover 1 3 1300230293 Condenser 1 4 1081990018 Outdoor Motor Supporter 1 5 1170040071 Outdoor Motor 1 6 1070030006 Propeller Fan 1 7 1081990011 Left Grille Supporter 1 8 1081990016 Front Plate 1
9 1071990044 Fan Guard 1 10 1100170010 Compressor And It 1 11 1120110002 4-way Valve 1 12 1120250991 4-way Valve Assembly 1 13 1091990046 Base 1 14 1081990012 Right Plate 1 15 1120120008 Two-way Valve 1 16 1081990013 Valve Supporter 1 17 1120130011 Three-way Valve 1 18
1073521301
Electrical Box Cover 1
19 1070040001
Cable Clamp(φ6)
1
20 1070040003
Cable Clamp(φ8)
1 21 1170500131 Terminal 1 22 1170100031 Fan Motor Capacitor 1 23 1170100014 Compressor Capacitor 1 24 1080010006 Capacitor Strip 1 25 1081990010 Electrical Parts Box 1 26 1120250988 Capillary Assembly 1 27 1081990019 Partition plate 1 28 1190070014 Base Carton 1 29 1190070008 Cabinet Carton 1 30 1190070016 Base Foaming 1 31 1190070015 Cover Forming 1
Not shown in the Explosion view.
Outdoor Unit- DSH 105 R/C
TCL Air Conditioner Service Manual
26
No. Part No. Part Name Q’ty Remark
1 1071990039 Grille 1
Optional
2 1080320105 Top Cover 1 3 1110060973 Condenser 1 4 1080050004 Outdoor Motor Supporter 1 5 1170040058 Outdoor Motor 1 6 1070030033 Propeller Fan 1 7 1080050001 Left Grille Suppoeter 1 8 1080320113 Front Plate 1
9 1080320112 Fan Guard 1 10 1100170028 Compressor And It Accessories 1 11 1120110002 4-way Valve 1 12 1120320915 4-way Valve Assembly 1 13 1081990209 Base 1 14 1080050002 Right Plate 1 15 1120120016 Two-way Valve 1 16 1080050003 Valve Supporter 1 17 1120130021 Three-way Valve 1 18 1073551103 Electrical Box Cover 1 19 1070040002
Cable Clamp(φ7)
1
20 1070040003
Cable Clamp(φ8)
1 21 1170500131 Terminal 1 22 1170100010 Fan Motor Capacitor 1 23 1170100003 Compressor Capacitor 1 24 1080010006 Capacitor Strip 1 25 1081990010 Electrical Parts Box 1 26 1120320914 Capillary Assembly 1 27 1081990019 Partition plate 1 29 1190070017 Base Carton 1 30 1190320718 Cabinet Carton 1 31 1190070019 Base Foaming 1 32 1190070018 Cover Forming 1
27
Outdoor Unit- DSH 135 R/C
TCL Air Conditioner Service Manual
Not shown in the Explosion view.
No. Part No. Part Name Q’ty Remark
1 1083520101 Grille 1
Optional
2 1081990056 Top Cover 1 3 1110060506 Condenser 1 4 1081990060 Outdoor Motor Supporter 1 5 1170040100 Outdoor Motor 1 6 1070030040 Propeller Fan 1 7 1081990053 Left Grille Supporter 1 8 1081990058 Front Plate 1
9 1081990059 Fan Guard 1 10 1100110020 Compressor And It Accessories 1 11 1120110003 4-way Valve 1 12 1120520760 4-way Valve Assembly 1 13 1081990249 Base 1 14 1081990054 Right Plate 1 15 1120120016 Two-way Valve 1 16 1081990055 Valve Supporter 1 17 1120130024 Three-way Valve 1 18 1073551103 Electrical Box Cover 1 19 1070040001 Cable Clampφ61 20 1070040003 Cable Clampφ81 21 1170500131 Terminal 1 22 1170100030 Fan Motor Capacitor 1 23 1170100004 Compressor Capacitor 1 24 1080010006 Capacitor Strip 1 25 1081990010 Electrical Parts Box 1 26 1120501129 Capillary Assembly 1 27 1081990071 Partition plate 1 28 1174561802 Outdoor sensor 1 29 1190070064 Base Carton 1 30 1190500898 Cabinet Carton 1 31 1190070066 Base Foaming 1 32 1190070124 Cover Forming 1
Outdoor Unit- DSH 195 R/C
TCL Air Conditioner Service Manual
28
Not shown in the Explosion
view.
No. Part No. Part Name Q’ty Remark
1 1083520101 Grille 1
Optional
2 1081990056 Top Cover 1 3 1110060885 Condenser 1 4 1081990060 Outdoor Motor Supporter 1 5 1170040100 Outdoor Motor 1 6 1070030040 Propeller Fan 1 7 1081990053 Left Grille Supporter 1 8 1081990258 Front Plate 1
9 1071990096 Fan Guad 1 10 1100040068 Compressor And It Accessories 1 11 1120110001 4-way Valve 1 12 1120701279 4-way Valve Assembly 1 13 1080500328 Base 1 14 1081990054 Right Plate 1 15 1120120011 Two-way Valve 1 16 1081990055 Valve Supporter 1 17 1120130013 Three-way Valve 1 18 1073551103 Electrical Box Cover 1 19 1074060118 Cable Clamp 1 20 1170200054 Terminal 1 21 1170100030 Fan Motor Capacitor 1 22 1170100007 Compressor Capacitor 1 23 1080010006 Capacitor Strip 1 24 1081990072 Electrical Parts Box 1 25 1174561801 AC Contactor 1 26 1120701269 Capillary Assembly 1 27 1081990071 Partition plate 1 28 1174561802 Outdoor Defrost Sensor 1 29 1190500898 Cabinet Carton 1 30 1190070124 Cover Forming 1 31 1190070064 Base Carton 32 1190070066 Base Foaming
TCL Air Conditioner Service Manual
29
Outdoor Unit- DSH 265 R/C
Part List