Instruction manual for spiral mixer mod. CPM80-200
DEKEGHEL
Dekeghel sa
rue de Tubize 8
1460 Ittre
Belgium
Tel +32 (0)67 64 63 16
Fax +32 (0)67 64 77 15
info@dekeghel.com
www.dekeghel.com
INSTRUCTION MANUAL
AUTOMATIC SPIRAL
MIXERS 80-200
MODELS CPM, CPMel
1
Instruction manual for spiral mixer mod. CPM80-200
Index
General Information Pag.4
Documentation supplied 4
This manual 4
Information property rights 4
Conventions 5
Manufacturers identification details 6
Machine identification details 6
EC declaration of conformity CE 7
Guarantee 7
Use of the manual 8
Description of the machine 9
Main parts of the machine 10
Security information 11
Safety criteria 11
Qualification of personnel 12
Safeguards 13
Hazardous areas and residual risks 16
Machine specification
Technical specifications 17
17
Installation 18
Hazardous areas and residual risks during installation 18
Qualifications of the operator 18
Transport 19
Preliminary operations 21
Installation 21
Preparation for start-up 22
Testing 22
Operator interface 24
Controls
Machine operation 26
Qualification of the operator 26
Spiral mixer model CPM 26
Spiral mixer model CPMel 28
Instruction manual for spiral mixer mod. CPM80-200
Trouble-shooting 36
Qualification of the operator 36
Machine scrapping 38
Qualification of the operator 38
Disconnecting the machine 38
Disconnecting procedure 38
Residual risks after machine disconnection 39
List of attached documentation 39
3
Instruction manual for spiral mixer mod. CPM80-200
Cap. 1
1.1
1.2
Documentation supplied
• Instruction manual ( this booklet )
• Spare parts catalogue
Other documentation
• Wiring diagrams
This manual
ADRESSEES
• Carrier
• Installer
• End user
• Maintenance engineer
General information
1.3
Information property rights
This manual contains copyright information. All rights are reserved. No part of this
manual can be reproduced or photocopied without prior written permission of the
manufacturer. Permission to use this documentation has only been given to the
customer to whom this manual has been supplied as part of the machine’s equipment
and only for the purpose of installation, operation and mainteanance of the machine
to which the manual refers.
The manufacturer declares that all the information container herein is in accordance
with the technical and safety specifications of the machine to which the manual refers.
The manufacturer will not be held responsible for direct or in direct damage or injury
to people, objects or animals resulting from the use of this documentation or the
machine in non-standard conditions.
The manufacturer reserves the right to introduce technical modifications or
improvements both to the documentation and to the machines without prior notice.
Modifications and improvements may also concern machines of the same model
described in this manual, but which have a different serial number. The information
container herein refers in particular to the machine specified in 1.6 “ Machine
identification details “ .
4
1.4
Conventions
LINGUISTIC CONVENTIONS
On the left, on the right : When speaking of such, we refer to the operator’s
•
position when facing the control panel.
•Qualified workers : all those people who thanks to their training,
experience, education as well as their knowledge of standards, regulations,
safety precautions and operation conditions, have been authorised by the
people in charge of the plant safety to carry out any necessary action and are
capable of identifying and avoiding possible danger.
PRINTING CONVENTIONS
PSE: Personal Safety Equipment
: Where N represents a generic number ( e.g. ); symbolic representation
of a control or warning device ( e.g. buttons, selectors and indicator lights ).
: Where L represents a generic letter ( e.g. ); symbolic representation of
the machine.
Instruction manual for spiral mixer mod. CPM80-200
NOTE: Notes contain important information and are highlighted separately from the
text to which they refer.
BEWARE : Beware indications describe the procedures, the partial or total nonobservance of which can cause damage to the machine or to the devices connected to
it.
DANGER: Ranger indications describe the procedures, the partial or total nonobservance of which can injure or harm the operator.
5
1.5
1.6
Instruction manual for spiral mixer mod. CPM80-200
Manufacturer identification details
Machine identification details
Type: AUTOMATIC SPIRAL MIXER MOD.
Fig. 1.1 Position of the name plate
CPM 80-200
6
1.7
1.8
Instruction manual for spiral mixer mod. CPM80-200
EC declaration of conformity “ CE”
See Enclosure 1 EC declaration of conformity “CE”
Warranty
GENERAL CONDITIONS
• This machine ( indicatine the appropriate serial number ) is guaranteed for 12
months. This guarantee is, however, subject to the claim being made by means
of a registered letter, within 8 days after the discovery of the faults or defects
providing that confirmation and acknowledgement is obtained prior from the
manufacturer.
• The warranty covers the replacement or repair of the faulty part ( component,
machine or part of the machine ) but does not cover the cost of
dismantlement, re-assembly or shipping.
• The replacement of any part does not bring about the renewal of the guarantee
period for the entire machine, unless the entire machine was replaced.
Therefore, under no circumstance shall the manufacturer be liable for
compensation of whatever type and the purchaser shall relinquish any claim
for damage, loss or expense, even to third parties arising from the machine
stoppage.
• The guarantee does not cover the electrical parts and the parts subject to
normal wear or deterioration due to external atmospheric or environmental
agents nor does it cover any defects arising from poor or insufficient
maintenance, nor does it cover the misuse of unqualified personnel,
unauthorised alterations or tampering of any kind.
• The validity of the warranty is subject to the performance of correct
maintenance as described in Chapter 7 “Maintenance” of this instruction
manual.
• The warranty is not valid if payment conditions have not been observed.
• If parts are supplied by some other manufacturer, he is responsible for the
warranty of these parts.
• Any controversy shall be governed directly by the court of Competent
Jurisdiction.
NOTE: In the event of repairs performed at the place where the machine is
installed, the machine guarantee certificate must be presented to the service
engineer and the guarantee is valid only if fully completed.
THE GUARANTEE WILL EXPIRE IN THE FOLLOWING CASES :
• Improper use of the machine ( see
• Use of different equipment from those specified in Chapter 7 “Maintenance”
• Assembly of the machine in different conditions from those specified in Chapter 4
“Installation”.
• Connections which fail to comply with the specifications given in Chapter 4 “
Installation”.
• Use of non-original parts.
Improper use pag. 9).
7
Instruction manual for spiral mixer mod. CPM80-200
REQUEST FOR SPARE PARTS
When requesting spare parts please state the following information :
• Type of machine
• No. Of production order marked on the label.
• Year of production.
• Reference number of the required part which can be found on the correspondent
drawing.
1.9
Use of the manual
Read carefully the following chapters : Charter 1 “ General information”, Charter 2
“Safety Information”, Chapter 3 “Machine specifications”, Chapter 5 “Operator
interface”. Consult the relevant charter before attempting installation, operation,
maintenance or dismantlement.
NOTE: This manual must be kept in good conditions for the whole life of the
machine and should be stored where it can be easily found when required. The
manual should be handed over to the purchaser of the machine if it is sold to someone
else.
8
Instruction manual for spiral mixer mod. CPM80-200
1.10
Description of the machine
INTENDED USE:
INTENDED OPERATIONS
The machine has been built and designed for cake and bread mixing to obtain shorter
working times.
The working cycle can be manual or automatic with two speeds and a premixing cycle,
all with timer.
CONDITIONS OF USE INTENDED
The machine has been designed and built to operate in a closed environment,
protected from atmospheric agents.
INTENDED USE OF POWER
The machine is driver by electric energy, which is converted into mechanical energy for
the intended operations.
IMPROPER USE
Improper use means any operation not expressly stated in the intended uses indicated
at the beginning of the paragraph, in particular :
• Use of the machine in an explosive environment
• Use of the machine in a flammable environment
• Washing the machine control panel with jets of water.
MACHINE STRUCTURE
This section describes the main machine components and their function within the
production cycle.
MAIN MACHINE COMPONENTS
The machine is composed of the following principal components :
• Body of the machine
• Mixing unit
• Transmission unit
• Electric panel
9
Fig. 1.2 Main parts of the machine
Instruction manual for spiral mixer mod. CPM80-200
10
Instruction manual for spiral mixer mod. CPM80-200
Chapter2
2.1
Safety information
Safety criteria
During the design and construction of this machine the manufacturer has adopted the
criteria and devices needed to satisfy the essential safety requirements imposed by the
Machinery Safety Directive 89/392/EEC and subsequent amendments, by the Low
Voltage Directive73/23/EEC and subsequent amendments and by the
Electromagnetic Compatibility Directive 89/336/EEC and subsequent amendments.
The careful analysis of risks carried out by the manufacturer has eliminated most of
the risks ( predicted or reasonably predicable ) linked to the machine operation
conditions.
The complete documentation of the safety measures taken is container in the technical
brochure of the machine kept at C.P. s.p.a.
The manufacturer strongly recommends careful observation of the instructions,
procedures and recommendations container herein as well as strict observation of the
current safety regulations regarding the work environment. This also applies to the use
of both the correct personal safety equipment and machine protection devices.
DANGER: Do not wear loose clothing, ties, chains, or watches that could get cought
into the moving parts of the machine.
NOTE: The manufacturer will not be liable for any damage or injury to persons,
animals or things caused by non observance of the safety rules and/or
recommendations supplied. .
11
Instruction manual for spiral mixer mod. CPM80-200
2.2
Qualification of personnel
STAGE QUALIFICATION OF THE OPERATOR IN CHARGE
Transport Qualified carrier informed of :
Charter 2
manual
Installation
Programming and setting up Qualified programmer and inspector informed of :
Operation Trained worker informed of :
Maintenance
Scrapping Qualified mechanic informed of :
Qualified electrician and qualified mechanic informed of :
Chapter 2 S
Chapter 3
Chapter 4
Chapter 5
Chapter 2 S
Chapter 3
Chapter 5
Chapter 6
Chapter 2 S
Chapter 3
Chapter 5
Chapter 6
There are three different types of workers who can carry out
interventions on the machine :
• Mechanical maintenance engineer : qualified
• Electrician : qualified engineer able to operate the
• Manufacture’s engineer : qualified engineer put at
engineer able to operate the machine in normal
conditions and with the machine guards open. Able to
carry out adjustments, maintenance and repairs on
mechanical parts. This worker should not be assigned
to electrical interventions on live parts.
machine in normal conditions and with the machine
guards open. Able to carry out electrical adjustments,
maintenance and repairs. This worker can be assigned
to electrical interventions on live parts inside the
electric control box.
customer’s disposal to carry out complicated repairing
in special conditions, according to the agreements
taken with the customer.
afety information,
Machine scrapping
NOTE: Themanufacturer will not be liable for damage or injury to people, animals or things
resulting from the actions of unqualified operators.
12
2.3
Safeguards
DEFINITION
Safeguards are all safety measures which involve the application of specific technical
mechanisms ( guards, safety devices ) to protect people from dangers which cannot be
made sufficiently harmless through design.
FIXED AND MOVEABLE GUARDS
• All power transmission components are shielded by screw fastened guards ,
in compliance with the EN 593 standard.
• Safety grille which prevents access to the bowl during the work process.
• Safety guard for the electrical system
Fig. 2.1: Fixed and moveable guards
Instruction manual for spiral mixer mod. CPM80-200
13
Instruction manual for spiral mixer mod. CPM80-200
PASSIVE SAFETY DEVICES
DEFINITION
The passive safety devices are those devices or safeguarding tecniques which eliminate
or reduce potential hazards for the operator without the operator having to actively
intervene.
LIMIT SWITCH DEVICES
The machine is equipped with the following limit switch microswitches
• The microswitch SQ1 acts by stopping the machine during operation if the safety
grill is lifted Fig. 2.1
Fig. 2.2: Limit switches
14
Instruction manual for spiral mixer mod. CPM80-200
ACTIVE SAFETY DEVICES
DEFINITION
Active safety devices are those devices or safeguarding techniques which eliminate or
reduce potential hazards and which require active and conscious intervention by the
operator in order to activate their accident prevention action.
EMERGENCY STOP
The machine is equipped with an emergency button located on the main
control panel of the machine and allows the operator to stop the machine in case of
emergency.
Fig. 2.3: Emergency button
SAFEGUARDING
• The electrical equipment offers protection against personal injury caused by
electrical discharge due to direct or indirect contact, all in compliance with the
CEI EN 60204-1 standards.
• All electrical power parts are container in the electrical box protected to IP54, in
compliance with the CEI EN 60204-1 standard. The control and power supply
voltages for all accessible parts are 12 and 24V for the CPM EL models ; 110V for
the CPM models. Moreover, both these lines are protected against short-circuiting
and accidental contact to earth.
DANGER: Tampering with the safety devices creates hazards for the machine
operators and other exposed persons.
NOTE: The manufacturer will not be liable for injury or damages to people, animals
or things caused by tampering with the machine’s safety devices.
15
2.4
Instruction manual for spiral mixer mod. CPM80-200
Hazardous areas and residual risks
DEFINITION:
A hazardous area is any area inside or near the machine which can could constitute a
risk for the health and safety of an exposed person.
This manual indicates all the procedures during which residual risks for the operator
are present. The residual risks can be eliminated by carefully following the procedures
indicated in this manual and by using the recommended personal safety equipment.
Protective gloves must be worn.
Protective footwear must be worn.
Protective overall must be worn.
Handling area of the packed or unpacked machine. The following risks are present
here :
• Impact hazard for the operator
• Crushing hazard.
The following PSE must be used be the operator:
Protective footwear, overalls and gloves.
DANGER: The manufacturer will not be liable for damage or injury to people,
animals or things resulting from non-compliance to the safety rules or from the
recommended PSE not being worn.
16
Instruction manual for spiral mixer mod. CPM80-200
±1% of rated frequency in continous running.
±2% of rated frequency for a short working period.
NOTE: The manufacturer will not be liable for defects, breakdowns or malfunctioning
arising from the non-compliance with the power supply values stated.
Capacità
farina
Flour
capacity
Motore
Spirale
Spiral
motor
Motore
vasca
Bowl
motor
Dimensioni
Dimensions
A B C
Peso
Weig
ht
17
Instruction manual for spiral mixer mod. CPM80-200
Capitolo 4
Installation
4.1 Hazardous areas and residua risks during installation
Protective gloves must be worn
Protective footwear must be worn.
Protective overalls must be worn
Handling area of packed or unpacked machines
The following risks are present here :
• Impact hazard for operator
• Crushing hazard
The above PSE must be used by the operator.
DANGER: During unloading, hoisting and handling of the machine, personnel
must wear the appropriate PSE, such as gloves, boots, helmets and the use of
appropriate tools.
4.2 Qualification of the operator
The installation of the machine should only be carried out by trained, qualified and
authorised personnel after having read and understood the information given in this
manual.
18
4.3 Transport
The instructions given in this section must be carefully followed when transporting the
machine. This operation may include the following situations :
• Storage of the machine
• Initial installation of the machine
• Re-location of the machine.
TRANSPORT CONDITIONS
The machine and its equipment can be transported in the following ways, according to
the customer’s requirements :
• In a wooden box pallet
• By road vehicle
• In each of these cases, before transport or handling, the various accessories
must be packed and fastened to the machine.
NOTE: Follow standard precautions to avoid collisions and tipping over.
LIFTING
Instruction manual for spiral mixer mod. CPM80-200
DANGER:
• It is forbidden to climb onto the machine and/or its packing or stop and/or pass
under the machine during handling.
• Access to the lifting and handling area is denied to all personnel except those
directly involved in the operations.
• All operators should remain at safe distance in order to avoid being hit by the
machine or any of its parts which may accidentally fall.
• Before starting the lifting operations the whole of the machine handling area,
including the parking area for the means of transport and the machine installation
area, should be identified and inspected in order to detect any potentially
hazardous areas.
• Use a bridge crane, a crane or a forklift truck with adequate lifting capacity. The
use of inadequate lifting equipment may cause damage to the machine or injury to
the personnel.
• Check that the hoisting cables or ropes are equipped with a bell and have the label
which contain all the manufacturer’s details and that the lifting capacity is clearly
stated.
• Check the cables or ropes before each lifting operation. Do not use them if they
are damaged or worn or have broken strands or wires.
• Never twist or knot ropes or cables. Always follow the instructions supplied by the
manufacturer.
• Follow the same precautions when using chains or belts.
19
Instruction manual for spiral mixer mod. CPM80-200
Fig. 4.1: Lifting with ropes Fig. 4.2: Lifting with pallet
ATTENTION: If the machine has been damaged durino transport, inform the
manufacturer immediately. The manufacturer should also be informed if there are
differences be tween the “ packing list “ and the goods that were actually delivered.
The machine and its equipment should be protected from external atmospheric
agents. In particular water and damp can cause certain machine components to rust,
causing irreversible damage.
20
Instruction manual for spiral mixer mod. CPM80-200
4.4 Preliminary operations
CHECK IF THE MACHINE HAS BEEN DAMAGED DURING TRANSPORT
Check the condition of the machine taking a close look at the outside and the inside.
Any deformation of the visible parts indicates that the machine has been hit by
something during transport. This could lead to malfunctioning.
Check the tightening of screws, bolts and fittings.
If damage has occurred
Damage caused by transport should be attributed to the carrier and the manufacturer
or its agent should be informed immediately of the situation.
Cleaning of the machine
• Remove the dust and dirt deposited on the surface during transport.
• Carefully clean and dry each part ( varnished or unvarnished ) using soft, clean
and dry cloths.
ATTENTION: It is strictly forbidden to climb onto the box pallets and/or to stow
them one on top of the other.
• Should the box pallets remain outdoors for some time, waiting to transported
inside the building, these box pallets should be covered with adequately-sized
waterproof tarpaulins.
• If storage exceeds 3 months the box pallets should be stored inside, sheltered
from bad weather and protected from excessively high or low temperatures.
• If the machine is unpacked, it should be covered in order to prevent the build-
up of dust and dirt.
4.5 Installation
Features of the installation site
A suitable installation site should be chosen considering the overall dimensions of the
machine, supplied in chapter 3.1 “specifications” at page 17, and in compliance with
the following rules :
• The power supply source, in compliance with the power supply details given on
page 17, should be near the installation site.
• Nothing should hinder the free movement of the operator around the
machine. The machine should be situated at least 1 metre from the nearest
wall or object.
• Cabinets should be accessible at all times and the doors should open wide
without obstacle.
• Make sure there is sufficient space for machine operation and maintenance
and also for any other additional equipment.
Protection against external atmospheric agents
The machine should be installed in a covered building, shielded from direct contact
with atmospheric agents.
21
Instruction manual for spiral mixer mod. CPM80-200
Lighting
Adequate lighting is necessary to carry out both normal operation and servicing of the
machine in a safe way. The machine has no built-in lighting system.
A well lit environment prevents hazards due to shadowed areas.
Acceptable environmental conditions for the installation site :
•Temperature : from 5°C to +40°C with the average temperature not exceeding
35°C over a period of 24 hours.
•Relative humidity: from 50% at a temperature of 40°C up to 90% at a
temperature of 20°C.
4.6 Preparation for start-up
The machine has only one connection to the main electricity supply
Electrical connections
Hydraulic connections
The machine ( model CPMel ) has only one hydraulic connection. The hose must have
a ½ “ fastening.
DANGER: Be sure that the values of the main electricity supply comply with the
power specifications of the machine.
Electrical hazards. Be sure that the machine is adequately earthed before making any
other connection to the main power supply.
4.7 Testing
Before delivery the machine is tested at the manufacture’s workshop where the
following operations are carried out :
• General setting of the machine, of auxiliary equipment and of the installed
safety devices.
• Running test to check all adjustments have been carried out ( correct rotation
of the motors, tightness of the pneumatic systems, effectiveness of safety
devices and of limit switches ).
• Performance of test cycles under safe conditions.
22
Instruction manual for spiral mixer mod. CPM80-200
Checking the safety devices:
Before starting the machine, the safety devices should be checked according to the
following procedure:
• Correct operation of the emergency stop button ( fig. 2.3, pag. 15 );
while the machine is working, press the emergency button : the machine
should stop immediately.
• Correct operation of the safety limit switches (fig.2.2, pag.14); while
the machine is working lift the protection grid (fig. 2.1 a pag.13). The
machine should stop immediately. .
ELECTRIC
CONNECTION
HYDRAULIC
CONNECTION
23
Instruction manual for spiral mixer mod. CPM80-200
Cap 5
Operator interface
5.1 Controls
Model CPM
Fig. 5.1: Control panel CPM
POSITION
Instant button Jogs the bowl to help the dough extraction.
DESCRIPTION FUNCTION
Two position selector When turned to the left : the manual operation
cycle is enabled.
When turned to the right : the automatic
operation cycle is enabled.
Three position selector Left position: clockwise bowl rotation
Middle position: no bowl rotation
Right position: anticlockwise bowl rotation
Red mushroom button on
a yellow background
Button I When pressed the spiral rotates at 1st speed and
Button II When pressed the spiral rotates at 2nd speed and
Timer Controls time of 1st speed
Timer Controls time of 2nd speed
Emergency button. When pressed it stops the
machine completely by cutting off the voltage
from the electric circuits.
the bowl rotates at chosen direction
the bowl rotates only anticlockwise
24
Instruction manual for spiral mixer mod. CPM80-200
POSITION DESCRIPTION FUNCTION
Model CPMel
Fig.5.2: Control panel CPMel:
Display Indicates the litres to be discharged ( during dosing )
or already discharged ( after pressing the stop button )
Display Electronic thermometer display
Button Controls manual stop of water discharge
Button Sets the quantity of water
Button To start discharge
Buttons To set the quantities
Display and
To select the program
button
Display and
To set the timer in phase 3
button
Display and
To select the automatic and manual cycle
button
Button To start the automatic cycle
Display and
To set the timer in phase 2
button
Button Commands the clockwise rotation of the bowl with a
jog movement
Display and
To set the timer in phase 1
button
Button To stop the cycle manually
Button Commands the anticlockwise rotation of the bowl
with a jog movement
Button To indicate the water temperature or the temperature
of the probe
Red mushroom button
Emergency button. Stops the machine completely
on a yellow background
25
Instruction manual for spiral mixer mod. CPM80-200 Instruction manual for spiral mixer mod. CPM80-200
Chapter 6
6.1
6.2
Qualifications of the operator
The machine should be used only by trained, qualified and authorised personnel who
have read and understood the information contained in this manual. The operator
must :
Spiral mixer model CPM
While reading this paragraph always refer to picture 5.1 at pag.23
Machine operation
• Pay special attention to the moving parts of the machine
• Take special care when activating the start buttons and only activate them after
making sure that persons or things are not in danger
• Do not rest tools or other objects on the machine, weather it is operating or
not.
• Connect the feeling cable to the electric connection and turn the main on-off
switch to position “I”.
• Be sure the emergency button is not pressed.
• Be sure that the protection grid (fig. 2.1 at pag.13) is lowered onto
the bowl
MANUAL MODE
• Position the selector in
• Decide the bowl rotation direction with the selector
• Press the button to start with the 1
• Press the button to pass to 2nd speed
• Stop the machine lifting up the protection grid
• With the protection grid open the only possible function is the rotation of the
bowl with a jog movement using the instant button
NOTE:
• It is possible to pass to 2nd speed only if the machine is already working.
• The bowl can rotate clockwise only in 1st speed
• To start the machine again after having lifted the protection grid, press the
button
5
5
st
speed
26
26
AUT
Instruction manual for spiral mixer mod. CPM80-200
OMATIC MODE
• Position the selector in
• Decide the bowl rotation direction with the selector
• Select the desired time of the 1st speed on the timer
• Press the button to put in function the 1
• achine will stop when the cycle has ended
• With the protection grid open th
Select the desired time of the 2nd speed on the ti• mer
st
5
speed, when the selected time
has passed the machine will pass to 2nd speed automatically.
The m
e only possible function is the rotation of the
bowl with a jog movement using the instant button
NOTE:
• The b
owl can rotate clockwise only in 1st speed
• To start the machine again after having lifted the protection grid, press the
button
, the working time selected will remain memorised.
5
27
Instruction manual for spiral mixer mod. CPM80-200
6.3
.3.1 TECHNICAL CHARACTERISTICS
6
6.3.2 DOSER, INSTALLATION
6.3.3 DOSER, INSTRUCTIONS FOR USE
Spiral mixer model CPMel
The CPMEL model can control the machine functions through programmable
settings. It can also control the Water Doser and the Thermic probe according to the
setts
ing programmed by the user.
When reading this paragraph, refer to picture 5.2 on pag.24
• Connect the feeling cable to the electric connection a t
switch to position “I”.
• Be sure the emergency button is not pressed.
Be sure that the protection grid (fig. 2.1 at pag.13) is lowered onto the
•
bowl
Softare SMDO.01a
w
Wa i
ter nlet 1/2 "
Maxim55° C
M
Minimum entry water pressure 1 bar
Maximum dosing 999,9 l
Dosing precision ±1%
Water delivery at
Water d iv55 l/min.
Tension
Frequency
Powr 10 VA
In case of hard water ( high percentage of calcium ) it is advisable to use a water
softner. This equipment must be programmed in order to leave a residual hardness of
approximately 5 to 10 french centigrades.
• Press the button : the display 1 flashes.
• Through the program the desired quantity of water, this
• Press the button : the valve opens automatically and the dosing starts.
• It is possible to stop water outlet in any moment pressing the button
um entry water temperature
aximum entry water pressure 5 bar
1 bar 25 l/min.
el ery at 5 bar
12V C.A.
50/60 Hz
e
buttons
will appear on the display 1..
nd urn the main on-off
The display will show the quantity of water discharged; it is sufficient to press the
button to finish the discharge.
28
Instruction manual for spiral mixer mod. CPM80-200
• For every extra dosing of the same quantity, it is sufficient to press button
6.3.4 SPI
AU
To e
display the program number appears.
• Press the button : on the display the last program selected will flash; use the
• Program the quantity of water desired following th
• Press the button : the time of phase 1 will flash on the display; ch
,
the doser is equipped with memory. Even in case of loss of power during the
working period, the memory will not be lost and it is sufficient to press button to
complete the dosing.
RAL MIXER, INSTRUCTIONS FOR USE
TOMATIC CYCLE
ent r in the automatic function mode , p ess button, so that on the r
buttons to choose a different program.
e instructions of the previous
paragraph.
aracterized
by the spiral rotatinrsdg in fi t spee and the bowl rotating clockwise. To modify use
the buttons
• Press the button : the time of phase 2 will flash on the display ; this
characterized by the spiral rotating in first speed and the bowl rotating
anticlockwise. To modify
use the buttons
• Press the button : the time of phase two will flash on the display,
charactarized by the spiral rotating in 2
anticlockwise. To modify use the button
• Press the button to start the c
• The machincally at the end of the cycle
e will stop automati
nd
speed and the bowl rotating
s
.
hosen program.
phase is
29
Instruction manual for spiral mixer mod. CPM80-200
NOTE:
• The phase 1 starts with a delay in relation to the water dosing.
• the
The 3 phases are carried out in sequence with a fixed 3 second delay between
first and second phase in order to obtain the complete stop of the bowl before the
inversion.
• Only in phase 2 of the automatic cycle the button can be used with the
following function: while it is kept pressed, the
bowl stops its rotation for 2", then
it inverts the sense of rotation until the button is kept pressed. When released, the
bowl stops again for 2
" and it starts the anticlockwise rotation. The phase 2 timer
continues the timing regularly and the spiral always rotates.
•Phase 3 follows immediately phase 2.
MANUAL CYCLE:
•also in the manual phase by selecting
All the phases described can be performed
the button : the figure “MA” will appear on the program display and all the
other displays will be at zero. To select the phases it is sufficient to press the
corresponding button and the display starts
corresponding phase start with the di
splay counting the time. Pressing stop the
to flash. Pressing the start button the
phase stops and the time remains fixed on
the display. Pressing the stop button
once again the timing goes to zero.
• If the button 2 and 3 are pressed during phase 1, nothing happens.
• ass directly
Viceversa it is possible to press the button while in phase 2 and p
in phase 3.
• With the machine stopped it is possible to start from any phase, but in phase 3 it is
not possible to start directly: the machine does 5” in phase 2 before passi
ng to
phase 3
• The machine can be stopped pressing the button
• n manual mode the doser works seperately in relation to the mixers functions.
I
To go back to the automatic cycles, press again the button .
NOTE:
With the protection grid open the machine stops immediately. Only the following
functions remain active :
• Rotation of the bowl with the two buttons
• Doser in manual position
NOTE:
When any of the protections are open , the cycle does not start automatically again,
but it is necessary to press start.
30
6.3.5 ATURE PROBE
TEMPER
The display normally indicates the entry temperature of the w
Pre
ssing the button , the word “TEMP” flashes on the display ;
while the temperature indication measured by the thermic probe is indicated on the
disp
lay .
Instruction manual for spiral mixer mod. CPM80-200
ater.
31
Instruction manual for spiral mixer mod. CPM80-200
Chapter 7
DAN
GER : Riscks of electric shocks and sudden movements of the machine during
maintenance.
Isolam electric and hydraulic means.
te the mac ine froh
Maintenance
7.1 Ordinary maintenance
For ordinary maintenance we intend all the operations that can be done by the operator. We
intend daily cleaning of the machine, periodic inspections in order to avoid future
inconveniences enabling the operator to use the machine securely.
The ordinary maintenance operations can be securely fulfilled by the operator only after
having read carefully the instructions given in this section.
CLEANING
For a general and constant good working of the machine we suggest a periodic general
cleaning. In particular
DANGER : During the general cleaning the machine must be isolated from the main
electric and hydraulic means.
For a general and constant good working of the machine we suggest a periodic general
cleaning. In particular :
• The machine must be cleaned after every working cycle.
• Keeping the machine cleaned helps to maintain efficient the most delicate parts of the
mixer and to enable to note easier any unusual mechanical wear or unfastening.
ATTENTION : Do not use water jets to clean both the control panel and the electric board.
TOOLS AND PRODUCTS FOR CLEANING :
ATTENTION : Avoid use of solvents or similar that could damage the painting or the
synthetic material.
Particularly, avoid the use of petrol and trichloroethylene.
32
Instruction manual for spiral mixer mod. CPM80-200
PART TO BE CLEANED
HOW AND WHAT TO USE
Stainless steel se hot water and a neutral degreaser for food.
Painted s
Contro panel l
Electric
FREQU ENCY :
parts For all electric parts use a vacuum cleaner.
U
nd a neutral degreaser for food. teel Use hot water a
o clean the panel use a cloth dampened with
T
water and neutral soap ; for more resistant dirt
use turpentine.
FREQUENCY
Weekly
onthly
Month
Monthly
7.2 Programmed maintenance
We intend with programmed maintenance all t
authorised personnel only. Periodic inspections in order to prevent any future failure and to
maintain the machines security standards.
UALIFICATION OF THE OPERATOR Q
he programmed maintenance operations can be securely fulfilled by qualified personnel
T
ained to use prepare and maintain the machine after having read and understood carefully
tr
e contents of this section.
th
articular attention must be paid to the belt tensioning.
P
PART TO BE CLEANED
Control panel.
Motors. M
Electrical parts ly
Spare parts
hose operations that can be fulfilled by
33
Instruction manual for spiral mixer mod. CPM80-200
DEKEGHEL
Dekeghel sa
rue de Tubize 8
1460 Ittre
Belgium
Tel +32 (0)67 64 63 16
Fax +32 (0)67 64 77 15
info@dekeghel.com
www.dekeghel.com
7.3 Procedure foioning
If the belt tens
• Remov
• Loosen the four screws that sustain the motor without unscrewing them completely.
• Resto
ion needs to be regulated, proceed as follows :
e the head cover
re the correct belt tension with the sc
loosen
ed.
r head belt tens
rew ; retighten all the screws previously
34
Loading...