DPS-1 Installation and operation instructions 4189360002 Rev. C
Disclaimer
The contents of this document are subject to revision without notice. DEIF A/S shall have no liability for any
error or damages of any kind resulting from the use of this document.
The English version of this document is the original language, and always contains the most recent and upto-date information about the product. Translations might not be updated at the same time as the English
version. DEIF A/S does not take responsibility for the accuracy of the translations. The English version
always takes precedence if there is any discrepancy.
Trademarks
DEIF DEIF is a registere d trademark of D EIF A/S
All trademarks are the properties of their respective owners.
8.1 Terms and abbreviations ................................................................................. 14
8.2 Units .................................................................................................................. 14
www.deifwindpower.com Page 3 of 14
Page 4
DPS-1 Installation and operation instructions 4189360002 Rev. C Introduction
1.Introduction
This document describes how to install and operate the DPS-1. The document is intended for
persons responsible for integrati on of th e DPS-1 in a pitch system, cabinet design, installation
and operation.
For detailed information about specifications and functions of the DPS-1, refer t o DPS-1
datasheet.
It is recommended to print this manual in colour in order to get most information out of the
pictures and illustrations.
1.1Revision history
Apart from editorial changes the following changes have been made in this revision:
Date Revision Changes
2017-06-27 C Total revision of document content.
2012-12-14 B New document
N/A A Not us ed
1.2Conventions
The following conventions are used in this document:
Used in document Description
A yellow symbol that illustrates hazard type (this symbol is an example for
general hazard). There are different types such as electrical, chemical and so
on.
Danger! A signal word used to indicate an imminently hazardous situation, which if not
avoided, will result in death or serious injury. (ISO 3864)
Warning! A signal word used to indicate an imminently hazardous situation, which if not
avoided, could result in death or serious injury. (ISO 3864)
Caution! A signal word used to indicate a potentially hazardous situation, which if not
avoided, could result in minor or moderate injury. (ISO 3864)
A blue symbol illustrates a need for mandatory action. In this example read
instructions. Other types of blue symbols exist and always indicate mandatory
action.
A symbol used to draw attention to extra information or an action that is not
mandatory
www.deifwindpower.com Page 4 of 14
Page 5
DPS-1 Installation and operation instructions 4189360002 Rev. C Safety precautions
Attention
Use eye, hand and hearing protection
Disconnect power
Danger!
2.Safety precautions
Company policy and local regulations regarding PPE must always be followed, regardless
whether the PPE is shown in this manual or not.
International standards such as IEC 364 and any other relevant international or national
standard regarding safety must be observed. Only qualified personnel who is fully capable
of recognizing, understanding and judging the dangers of the task at hand may perform the
work.
The installation and service of the units should only be handled by qualified persons, who are
conscious of the risks involved.
Ensure that the grounded connection wire of the line is correctly connected to the line input of
the unit. Load and service or measuring setup must be grounded, if possible, in order to
protect the units and the persons working with them.
During normal operation, the persons working with the units must have no contact to
dangerous voltages within the unit.
2.1Mechanical work
Use protection for eyes, hand and hearing, if the mounting holes for bolts need
to be made during production.
2.2Electrical work
Ensure that all power is disconnected when working with the DPS-1, except for during
commissioning and service.
Risk of burns and electrical shock from short circuit, electrical arc and uninsulated wires.
Commissioning and maintenance work on this device may only be carried out by a qualified
electrician. Observe local regulation when working with electrical components.
When the DPS-1 has been powered, there is a risk of stored energy even when the power
is disconnected. Wait 5 minutes after the power is disconnected and verify zero energy
www.deifwindpower.com Page 5 of 14
according to company procedures on the outputs before performing any work.
Page 6
DPS-1 Installation and operation instructions 4189360002 Rev. C Package content, tools and handling
Quantity
Description
Attention
3. Package content, tools and handling
3.1 Package content
3.1.1 Standard package content:
1 DPS-1 power supply
3.2Required tools and accessories
The following required tools and accessories are not delivered with the DPS-1.
Table 1 Required tools and accessories
Tool or accessory Torque Used to
Flat Screwdriver 3 mm wide N/A Connect / disconnect wires.
Press tool for ferrules N/A Press ferrules on wires.
Ferrules (recommended) N/A Terminate wires to connectors
Appropriate screwdriver for the
selected 4 mm mounting screws.
Optional, needed if chassis
mounting is selected.
4 pcs M4 screws
Optional, needed if chassis
mounting is selected.
4 pcs self-locking nut
Optional, needed if chassis
mounting is selected.
According to
screws spec.
According to
screws spec.
According to
screws spec.
(recommended, different size
according to wire size).
Fastening screws (M4).
Fasten the DPS-1 to the cabinet.
Length depends on the cabinet
structure.
Fasten the DPS-1 to the cabinet.
3.3Handling
www.deifwindpower.com Page 6 of 14
Page 7
DPS-1 Installation and operation instructions 4189360002 Rev. C Package content, tools and handling
Sufficient care must be taken to protect the terminal against electrostatic
discharges during the installation. Once the unit is installed and connected, these
precautions are no longer necessary.
www.deifwindpower.com Page 7 of 14
Page 8
DPS-1 Installation and operation instructions 4189360002 Rev. C Mechanical mounting
150
154
120
70
141
107
116
78.8
4.Mechanical mounting
Figure 1DPS-1 2405 mechanical drawing
The DPS-1 can be mounted on a 35 mm DIN rail, or by using 4 pcs. 4 mm screws and nuts
(chassis mount).
www.deifwindpower.com Page 8 of 14
Page 9
DPS-1 Installation and operation instructions 4189360002 Rev. C Mechanical mounting
Use eye, hand and hearing protection
107 mm
141 mm
Info
The vibration, shock and bump specifications apply for chassis mounting only
4.1DIN rail mounting
For DIN rail mounting just clips the DPS-1 onto the DIN rail (first top, then bottom).
4.2Chassis mounting:
Use protection for eyes, hand and hearing, if the mounting holes for bolts need
to be made during installation.
Drill six ⌀4 mm holes according to Figure 2 on page 9
the DPS-1. Use 4 pcs. 4 mm screws and nuts to mount the DPS-1. Torque according to bolt
specification.
and the cabinet drawings for mounting
Figure 2DPS-1 2405 drilling drawing
www.deifwindpower.com Page 9 of 14
Page 10
DPS-1 Installation and operation instructions 4189360002 Rev. C Electrical connections
- Protective Eart h
input
1
2
3
D C OK
D C OK
+
24V DC
-
-
Out
5
4
6
7
8
DPS-1
Info
5. Electrical connections
5.1 Connection diagram
The following figure shows the connections to the DPS-1.
Figure 3Connection diagram
Connect the wires to the DPS-1 according to the wiring diagram.
Terminals 7 and 8 are internally connected.
www.deifwindpower.com Page 10 of 14
Page 11
DPS-1 Installation and operation instructions 4189360002 Rev. C Electrical connections
Ferrule length
Attention
2 1 3
4
5.2General recommendations
It is recommended to use ferrules on the wires before connecting it to the connector. The
length of ferrule (termination sleeve) is the uninsulated part of the ferrule:
Figure 4Ferrule length definition
Follow the ferrule manufacturer instruction on how to use a ferrule.
Ferrules are mandatory if multiple wires are connected to the same terminal. Use
the same length as for single wire.
5.3Connecting wires to connectors
Table 2 Technical data for all connectors (D-ZFKDS 2.5)
Conductor cross section flexible, without ferrule 0.2 to 2.5 mm2
Conductor cross section flexible, with ferrule without plastic sleeve 0.2 to 2.5 mm2
Conductor cross section flexible, with ferrule with plastic sleeve 0.2 to 2.5 mm2
Stripping length 8 mm
Ferrule length 8 mm
To connect wires to terminals:
1. Use a flat screwdriver and press the spring in as illustrated (pos.1 and 2)
2. Press the wire all the way in (pos.3).
3. Lift the screwdriver (pos.4).
www.deifwindpower.com Page 11 of 14
Page 12
DPS-1 Installation and operation instructions 4189360002 Rev. C Operating the DPS-1
6.Operating the DPS-1
The DPS-1 is designed to operate without manual intervention. It is equipped with a visual
and electrical indication/alarm that continuously monitors the input and output voltage
6.1Voltage drop compensation
The power supply can be adjusted to compensate the voltage drop in the wiring between the
DPS-1 and the load. Examples of voltage drop can be found in the following table.
Wire cross section
(mm2)
0.75 5 5 1.25
1.00 5 5 0.9
1.50 5 5 0.6
2.50 5 5 0.35
* The voltage drop is based on threaded copper wire at 20ºC
The voltage drop formula is: V = length x current x cable resistance x 2
(thus the double current or double length will also double the voltage drop.
Example: 1.5 mm2, 5 m, 5A => V = 0.6 V
Setting: 24.0 + 0.6 = 24.6 V
Length (m) Current (A) Voltage drop* (V)
6.2Visual and electrical monitoring
DPS-1 has two monitoring types:
•Electrical monitoring: DPS-1 has a dry contact “DC O K” relay output which is closed
(energised) under normal operating conditions (no failure).
•Visual monitoring: A green LED provides visual indication of the DPS-1 operational
status.
The behavior of the LED and relay is according to the following table:
Table 3 LED and DC OK relay functions
Status LED DC OK relay contact
Normal operation with or without load Green Closed
High temperature/power derating Green Closed
Reverse polarity connection on output Green, flashing* Alternate open and closed*
Overvoltage on output Green, flashing* Alternate open and closed*
Short circuit on output Off Open
No output voltage Off Open
No input voltage Off Open
Under-voltage on input Off Open
* Changes state every approximately 0.5 seconds.
www.deifwindpower.com Page 12 of 14
Page 13
DPS-1 Installation and operation instructions 4189360002 Rev. C Disposal of the DPS-1
7.Disposal of the DPS-1
All products that are marked with the crossed-out wheeled bin (the WEEE
symbol) are electrical and electronic equipment (EEE). EEE contains
materials, components and substances that can be dangerous and harmful
to people's health and to the environment. Waste electrical and electronic
equipment (WEEE) must therefore be disposed of properly. In Europe, the
disposal of WEEE is governed by the WEEE directive issued by the
European Parliament. DEIF complies with this directive.
You must not dispose of WEEE as unsorted municipal waste. Instead,
WEEE must be collected separately, to minimise the load on the
environment, and to improve the opportunities to recycle, reuse and/or
recover the WEEE. In Europe, local governments are responsible for
facilities to receive WEEE. If you need more information on how to dispose
of DEIF WEEE, please contact DEIF.
www.deifwindpower.com Page 13 of 14
Page 14
DPS-1 Installation and operation instructions 4189360002 Rev. C Glossary
[º]
=
([º] − 32 º) ×5
9
8. Glossary
8.1 Terms and abbreviations
LED Light emitting diode
MCB Main circuit breaker
DPS DEIF Power Supply
8.2Units
Unit Unit
Name
A ampere Current
ºC degrees
Celsius
g gram Weight oz ounce 1 g = 0.03527 oz
Hz hertz
kg kilogram Weight lb pound 1 kg = 2.205 lb
m metre length ft foot (or feet) 1 m = 3.28 ft
mA milliampere Current
mm millimetre Length in inch 1 mm = 0.0394 in
ms millisecond Time
Nm Newton
metre
s second Time
V volt Voltage
Quantity name US
US name Conversion Alternative
unit
Temperature ºF Fahrenheit
Frequency (cycles
per second)
Torque Lb-in pound-force
inch
1 Nm = 8.85 lb-in
units
V AC volt
V DC volt (direct
W watt Power
www.deifwindpower.com Page 14 of 14
(alternating
current)
current)
Voltage
(alternating
current)
Voltage (direct
current)
Loading...