Deif DPS-1 Installation And Operation Instructions Manual

Page 1
INSTALLATI ON AND OPERATION INSTRUCTIONS
Power supply
DPS-1
Document no.: 4189360002 Rev.: C Date: 2017-06-27 Language: EN-GB
DEIF A/S ∙ Frisenborgvej 33 ∙ DK-7800 Skive Tel.: +45 9614 9614 ∙ Fax: 9614 9615
Info@deif.com ∙ www.deifwindpower.com
Page 2
DPS-1 Installation and operation instructions 4189360002 Rev. C
Disclaimer
The contents of this document are subject to revision without notice. DEIF A/S shall have no liability for any error or damages of any kind resulting from the use of this document.
The English version of this document is the original language, and always contains the most recent and up­to-date information about the product. Translations might not be updated at the same time as the English version. DEIF A/S does not take responsibility for the accuracy of the translations. The English version always takes precedence if there is any discrepancy.
Trademarks
DEIF DEIF is a registere d trademark of D EIF A/S
All trademarks are the properties of their respective owners.
Copyright
© Copyright DEIF A/S. All rights reserved.
www.deifwindpower.com Page 2 of 14
Page 3
DPS-1 Installation and operation instructions 4189360002 Rev. C Introduction
Contents
1. Introduction ......................................................................................................... 4
1.1 Revision history ................................................................................................. 4
1.2 Conventions ........................................................................................................ 4
2. Safety precautions ............................................................................................. 5
2.1 Mechanical work ................................................................................................. 5
2.2 Electrical work .................................................................................................... 5
3. Package content, tools and handling ............................................................... 6
3.1 Package content ................................................................................................. 6
3.1.1 Standard package content: ....................................................................... 6
3.2 Required tools and accessories ........................................................................ 6
3.3 Handling .............................................................................................................. 6
4. Mechanical mounting ......................................................................................... 8
4.1 DIN rail mounting................................................................................................ 9
4.2 Chassis mounting: ............................................................................................. 9
5. Electrical connectio n s ..................................................................................... 10
5.1 Connection diagram ......................................................................................... 10
5.2 General recommendations .............................................................................. 11
5.3 Connecting wires to connectors ..................................................................... 11
6. Operating the DPS-1 ......................................................................................... 12
6.1 Voltage drop compensation ............................................................................ 12
6.2 Visual and electrical monitoring ...................................................................... 12
7. Disposal of the DPS-1 ...................................................................................... 13
8. Glossary ............................................................................................................ 14
8.1 Terms and abbreviations ................................................................................. 14
8.2 Units .................................................................................................................. 14
www.deifwindpower.com Page 3 of 14
Page 4
DPS-1 Installation and operation instructions 4189360002 Rev. C Introduction

1. Introduction

This document describes how to install and operate the DPS-1. The document is intended for persons responsible for integrati on of th e DPS-1 in a pitch system, cabinet design, installation and operation. For detailed information about specifications and functions of the DPS-1, refer t o DPS-1 datasheet.
It is recommended to print this manual in colour in order to get most information out of the pictures and illustrations.

1.1 Revision history

Apart from editorial changes the following changes have been made in this revision:
Date Revision Changes
2017-06-27 C Total revision of document content. 2012-12-14 B New document N/A A Not us ed

1.2 Conventions

The following conventions are used in this document:
Used in document Description
A yellow symbol that illustrates hazard type (this symbol is an example for
general hazard). There are different types such as electrical, chemical and so on.
Danger! A signal word used to indicate an imminently hazardous situation, which if not
avoided, will result in death or serious injury. (ISO 3864)
Warning! A signal word used to indicate an imminently hazardous situation, which if not
avoided, could result in death or serious injury. (ISO 3864)
Caution! A signal word used to indicate a potentially hazardous situation, which if not
avoided, could result in minor or moderate injury. (ISO 3864)
A blue symbol illustrates a need for mandatory action. In this example read
instructions. Other types of blue symbols exist and always indicate mandatory action.
A symbol used to draw attention to extra information or an action that is not
mandatory
www.deifwindpower.com Page 4 of 14
Page 5
DPS-1 Installation and operation instructions 4189360002 Rev. C Safety precautions
Attention
Use eye, hand and hearing protection
Disconnect power
Danger!

2. Safety precautions

Company policy and local regulations regarding PPE must always be followed, regardless whether the PPE is shown in this manual or not.
International standards such as IEC 364 and any other relevant international or national standard regarding safety must be observed. Only qualified personnel who is fully capable of recognizing, understanding and judging the dangers of the task at hand may perform the work.
The installation and service of the units should only be handled by qualified persons, who are conscious of the risks involved.
Ensure that the grounded connection wire of the line is correctly connected to the line input of the unit. Load and service or measuring setup must be grounded, if possible, in order to protect the units and the persons working with them.
During normal operation, the persons working with the units must have no contact to dangerous voltages within the unit.

2.1 Mechanical work

Use protection for eyes, hand and hearing, if the mounting holes for bolts need to be made during production.

2.2 Electrical work

Ensure that all power is disconnected when working with the DPS-1, except for during commissioning and service.
Risk of burns and electrical shock from short circuit, electrical arc and uninsulated wires. Commissioning and maintenance work on this device may only be carried out by a qualified
electrician. Observe local regulation when working with electrical components. When the DPS-1 has been powered, there is a risk of stored energy even when the power
is disconnected. Wait 5 minutes after the power is disconnected and verify zero energy
www.deifwindpower.com Page 5 of 14
according to company procedures on the outputs before performing any work.
Page 6
DPS-1 Installation and operation instructions 4189360002 Rev. C Package content, tools and handling
Quantity
Description
Attention

3. Package content, tools and handling

3.1 Package content

3.1.1 Standard package content:

1 DPS-1 power supply

3.2 Required tools and accessories

The following required tools and accessories are not delivered with the DPS-1.
Table 1 Required tools and accessories
Tool or accessory Torque Used to
Flat Screwdriver 3 mm wide N/A Connect / disconnect wires.
Wire insulation stripping tool N/A Strip wires insulation
Press tool for ferrules N/A Press ferrules on wires.
Ferrules (recommended) N/A Terminate wires to connectors
Appropriate screwdriver for the selected 4 mm mounting screws. Optional, needed if chassis mounting is selected.
4 pcs M4 screws Optional, needed if chassis
mounting is selected. 4 pcs self-locking nut
Optional, needed if chassis mounting is selected.
According to screws spec.
According to screws spec.
According to screws spec.
(recommended, different size according to wire size).
Fastening screws (M4).
Fasten the DPS-1 to the cabinet. Length depends on the cabinet structure.
Fasten the DPS-1 to the cabinet.

3.3 Handling

www.deifwindpower.com Page 6 of 14
Page 7
DPS-1 Installation and operation instructions 4189360002 Rev. C Package content, tools and handling
Sufficient care must be taken to protect the terminal against electrostatic
discharges during the installation. Once the unit is installed and connected, these precautions are no longer necessary.
www.deifwindpower.com Page 7 of 14
Page 8
DPS-1 Installation and operation instructions 4189360002 Rev. C Mechanical mounting
150
154
120
70
141
107
116
78.8

4. Mechanical mounting

Figure 1 DPS-1 2405 mechanical drawing
The DPS-1 can be mounted on a 35 mm DIN rail, or by using 4 pcs. 4 mm screws and nuts (chassis mount).
www.deifwindpower.com Page 8 of 14
Page 9
DPS-1 Installation and operation instructions 4189360002 Rev. C Mechanical mounting
Use eye, hand and hearing protection
107 mm
141 mm
Info
The vibration, shock and bump specifications apply for chassis mounting only

4.1 DIN rail mounting

For DIN rail mounting just clips the DPS-1 onto the DIN rail (first top, then bottom).

4.2 Chassis mounting:

Use protection for eyes, hand and hearing, if the mounting holes for bolts need to be made during installation.
Drill six ⌀4 mm holes according to Figure 2 on page 9 the DPS-1. Use 4 pcs. 4 mm screws and nuts to mount the DPS-1. Torque according to bolt specification.
and the cabinet drawings for mounting
Figure 2 DPS-1 2405 drilling drawing
www.deifwindpower.com Page 9 of 14
Page 10
DPS-1 Installation and operation instructions 4189360002 Rev. C Electrical connections
- Protective Eart h
input
1
2
3
D C OK
D C OK
+
24V DC
-
-
Out
5
4
6
7
8
DPS-1
Info

5. Electrical connections

5.1 Connection diagram

The following figure shows the connections to the DPS-1.
Figure 3 Connection diagram Connect the wires to the DPS-1 according to the wiring diagram.
Terminals 7 and 8 are internally connected.
www.deifwindpower.com Page 10 of 14
Page 11
DPS-1 Installation and operation instructions 4189360002 Rev. C Electrical connections
Ferrule length
Attention
2 1 3
4

5.2 General recommendations

It is recommended to use ferrules on the wires before connecting it to the connector. The length of ferrule (termination sleeve) is the uninsulated part of the ferrule:
Figure 4 Ferrule length definition Follow the ferrule manufacturer instruction on how to use a ferrule.
Ferrules are mandatory if multiple wires are connected to the same terminal. Use the same length as for single wire.

5.3 Connecting wires to connectors

Table 2 Technical data for all connectors (D-ZFKDS 2.5)
Conductor cross section flexible, without ferrule 0.2 to 2.5 mm2 Conductor cross section flexible, with ferrule without plastic sleeve 0.2 to 2.5 mm2 Conductor cross section flexible, with ferrule with plastic sleeve 0.2 to 2.5 mm2 Stripping length 8 mm Ferrule length 8 mm
To connect wires to terminals:
1. Use a flat screwdriver and press the spring in as illustrated (pos.1 and 2)
2. Press the wire all the way in (pos.3).
3. Lift the screwdriver (pos.4).
www.deifwindpower.com Page 11 of 14
Page 12
DPS-1 Installation and operation instructions 4189360002 Rev. C Operating the DPS-1

6. Operating the DPS-1

The DPS-1 is designed to operate without manual intervention. It is equipped with a visual and electrical indication/alarm that continuously monitors the input and output voltage

6.1 Voltage drop compensation

The power supply can be adjusted to compensate the voltage drop in the wiring between the DPS-1 and the load. Examples of voltage drop can be found in the following table.
Wire cross section (mm2)
0.75 5 5 1.25
1.00 5 5 0.9
1.50 5 5 0.6
2.50 5 5 0.35
* The voltage drop is based on threaded copper wire at 20ºC The voltage drop formula is: V = length x current x cable resistance x 2
(thus the double current or double length will also double the voltage drop. Example: 1.5 mm2, 5 m, 5A => V = 0.6 V Setting: 24.0 + 0.6 = 24.6 V
Length (m) Current (A) Voltage drop* (V)

6.2 Visual and electrical monitoring

DPS-1 has two monitoring types:
Electrical monitoring: DPS-1 has a dry contact “DC O K” relay output which is closed (energised) under normal operating conditions (no failure).
Visual monitoring: A green LED provides visual indication of the DPS-1 operational status.
The behavior of the LED and relay is according to the following table:
Table 3 LED and DC OK relay functions
Status LED DC OK relay contact
Normal operation with or without load Green Closed High temperature/power derating Green Closed Reverse polarity connection on output Green, flashing* Alternate open and closed* Overvoltage on output Green, flashing* Alternate open and closed* Short circuit on output Off Open No output voltage Off Open No input voltage Off Open Under-voltage on input Off Open
* Changes state every approximately 0.5 seconds.
www.deifwindpower.com Page 12 of 14
Page 13
DPS-1 Installation and operation instructions 4189360002 Rev. C Disposal of the DPS-1

7. Disposal of the DPS-1

All products that are marked with the crossed-out wheeled bin (the WEEE symbol) are electrical and electronic equipment (EEE). EEE contains materials, components and substances that can be dangerous and harmful to people's health and to the environment. Waste electrical and electronic equipment (WEEE) must therefore be disposed of properly. In Europe, the disposal of WEEE is governed by the WEEE directive issued by the European Parliament. DEIF complies with this directive.
You must not dispose of WEEE as unsorted municipal waste. Instead, WEEE must be collected separately, to minimise the load on the environment, and to improve the opportunities to recycle, reuse and/or recover the WEEE. In Europe, local governments are responsible for facilities to receive WEEE. If you need more information on how to dispose of DEIF WEEE, please contact DEIF.
www.deifwindpower.com Page 13 of 14
Page 14
DPS-1 Installation and operation instructions 4189360002 Rev. C Glossary
]
=
(] 32 º) ×5
9

8. Glossary

8.1 Terms and abbreviations

LED Light emitting diode MCB Main circuit breaker DPS DEIF Power Supply

8.2 Units

Unit Unit
Name
A ampere Current ºC degrees
Celsius
g gram Weight oz ounce 1 g = 0.03527 oz Hz hertz
kg kilogram Weight lb pound 1 kg = 2.205 lb m metre length ft foot (or feet) 1 m = 3.28 ft mA milliampere Current mm millimetre Length in inch 1 mm = 0.0394 in ms millisecond Time Nm Newton
metre s second Time V volt Voltage
Quantity name US
US name Conversion Alternative
unit
Temperature ºF Fahrenheit
Frequency (cycles per second)
Torque Lb-in pound-force
inch
1 Nm = 8.85 lb-in
units
V AC volt
V DC volt (direct
W watt Power
www.deifwindpower.com Page 14 of 14
(alternating
current)
current)
Voltage (alternating current)
Voltage (direct current)
Loading...