COOKERHOODS
CHIMNEY TYPE
CONTENTS
2 Chimney Type 3 Wall Mounting 3 Option 1 – Recirculated Air 3 Option 2 – Outside Venting 4 Electrical Installation 4 Controls 4 Operation 4 Caution 5 Canopy Type
5 Cupboard Installation
6 Wall Mounting 7 Optional Rear or Top Venting Installation 7 Operation
www.defy.co.za
8 Maintenance

CHIMNEY TYPE

CAUTION
The exhaust air from the chimney hood must not be discharged into a flue or chimney which is used for exhausting the fumes from other appliances burning gas or fuels. Please ensure that the regulations concerning the discharge of exhaust air have been fulfilled.
(SABS IE C60335-2-31)
All models have the ability to either re-circulate the filtered air back into the kitchen, or to exhaust the filtered air through an outside wall or chimney pipe. Decide on which option best suits you before commencing with the installation.

WALL MOUNTING

Remove the aluminium grease filters (perforated plates) from the base of the
hood.
The hood must be mounted directly over the cooking area. The minimum distance
between the cooking surface and the underside of the hood must be 650 mm. for electric cookers and 750 mm. for gas burners.
Hold the body of the hood in position against the wall and mark the two keyhole
and two retaining hole positions.
Drill and fix four rawl plugs at the marked positions.
Screw suitable mounting screws into the wall at the two marked keyhole
positions.
Attach the spigot to the flange using the self tapping screws supplied.

OPTION 1 – RECIRCULATED AIR

Fit the T-piece to the spigot.
Fit the larger of the two chimney pieces to the main body using the four M4
screws supplied.
Lift and hang the hood and chimney assembly on the two keyhole mounting
screws.
Fit and tighten two suitable retainer screws ensuring all the while that the hood is
level.
Use the mounting bracket as a template and mark the hole positions. Drill and
attach the mounting bracket to the wall at the marked positions. Reposition the top chimney piece so that the side holes correspond with the holes in the bracket. Fix with two self tapping screws.

OPTION 2 – OUTSIDE VENTING

Do not fit the T-piece to the spigot.
Instead connect a 125 mm. diameter flexible duct straight onto the spigot flange.
Ensure that the duct vents to the outside air.
To prevent the risk of fire, do not discharge the exhaust air into a flue from other
appliances burning gas or fuel.
Fit the hood and chimney assembly as described in option 1