YOU CAN RELY ON DEFY
Installation
Safety
Maintenance
Installer Details
Service
MODEL
DGS 150
GAS / ELECTRIC
STOVE
Page 1
Part Number 066200
Introduction
This manual deals specifically with the Installation, Safety, Maintenance, Installer Details, Service and Warranty aspects of your new Defy Stove. It should be read in con-
junction with the separate instruction handbook supplied.
Unpacking
• Please ensure that packaging material is disposed of in a responsible manner.
• Plastic bags should be cut up to prevent children playing with them and acciden-
tally suffocating.
• If the appliance is damaged in any way, do not use it. Report the damage to your
dealer, who will take the necessary corrective action.
Instructions for the installer
Electrical installation
• Insert the fitted 15A. -3pin moulded plug into a 15A. earthed wall socket.
• This appliance must be earthed. The manufacturer and the seller do not accept re-
sponsibility for any damage due to incorrect installation or electrical connection.
LPG (Liquid Petroleum Gas) Installation
• The installation must conform with the requirements of SANS 10087-1.
• Soak the end of the plastic hose in hot water to soften it and then push the hose end
fully over the hose nozzle. (See sketch 1 below)
• Secure the hose by tightening the hose clamp. ( See sketch 2 bel o w)
• Similarly, secure the other end of the hose to the regulator on the gas bottle.
O Seal
REGULATOR
Clamp
1 2
Caution: Never use a naked flame to check for gas leaks
• Check for gas leaks after installation and whenever a new or re-filled gas bottle is
used for the first time.
• Ensure that the control knobs on the hob are in the OFF position.
• Open the valve on the Gas bottle.
• Using a small paint brush, apply some soapy water to all the connections.
• If there is a leak, bubbles will appear.
• If this happens, close the valve on the gas bottle.
• Check and tighten the connections immediately.
• Repeat the procedure to ensure that there are no further leaks.
Page 2
Safety compliance with local requirements
Flexible hose - Not supplied.
• Any hose that is used to connect the stove to the gas system shall comply with
SANS 1156-2 or BS 3212.
Temporary installation.
• Flexible hose connection from the gas appliance to the cylinder can be made by the
user. Ensure that pipe clamps are tightened correctly and are of good quality.
Gas cylinder - Not supplied.
• For best results we recommend that gas cylinders with a minimum capacity of 19kg
be used.
Regulator - Not supplied.
• A 2,8 kPa LPG gas regulator which complies with SANS 1237 must be used.
Permanent installation.
• The appliance may only be installed by a Qualified Gas Fitter who is registered with
the LPGSASA. (Liquid Petroleum Gas Association of Southern Africa)
• All registered Gas Fitters are issued with an identity card which carries their
registration number. Make a note of this in the box below.
• The Gas Fitter should also provide you with a written certificate after completion of
the work. Failure to comply with the above will render the warranty invalid.
• Before the installer hands over the installed appliance be sure that you fully
understand:
a) The position of the isolation or shut-off valve in the gas supply line to the appliance.
b) The requirements for safe operation of the appliance.
Note:
• This appliance is supplied ex-factory with jets and air settings for use
with LPG gas only.
• We strongly recommend that the changing of the jets and air flow
adjustment be carried out by a trained Defy technician.
Installer’s details to be filled in below
Page 3