The P2P- Wireless Input Node is part of the Dene Instruments Twin Link point-to-point system. It oers an ideal starting point for wireless transmission of a range of digital and analogue input signals.
2x Isolated Universal Inputs Thermocouple, RTD, mA, V, mV,
potentiometer, digital pulse and AC current sensors
4x digital inputs, 2x digital outputs, and 2x relays
Flexible IO enables a range of setpoint functions
Transmit up to 1.5km (0.9mi) Line Of Sight
Simple USB setup using Define ToolBox
Free download from defineinstruments.com/toolbox
P2P-
Wireless Input Node
Specications
General
Power supply 9–36V DC, 2.5VA max
Isolation 1500V AC between power
supply and input channels
Simple soware programming using Dene ToolBox Bridge Key required,
sold separately
Transmission
RF data rate 250Kb/s
RF frequency range 2405-2475MHz
RF receiver sensitivity -110dBm
RF transmission power +20dBm
(Optional low power setting [10dBm] selectable in soware)
Transmission range Up to 1.5km (0.9mi) LOS with supplied antenna (WG-3DBI). All nodes must be set to full power [+20dBm] for max range.
Number of RF channels 15
Up to 17 wireless nodes per mesh
Twin Link (P2P- & P2P-O) plus up to 15x Repeaters (P2P-R)
Spreading method Direct sequence
Modulation O-QPSK
Relay Outputs
2x Relay outputs Form A relays (5A 250V AC / 5A 30V DC)
Isolation to sensor and user input commons 2300Vrms for 1min.
Working voltage 250V AC
Life expectancy 100K cycles min at full load rating
Digital IO's
4x Digital inputs Max rate 1Hz. Selectable sink/source. Suitable for clean contacts, NPN, PNP and voltage inputs (low input <1.4V DC, high input
1.4–30V DC)
Max continuous input 20V DC
Not isolated to power supply common
2x Digital outputs Open drain (1A,
30V DC max)
Construction
35mm DIN rail mount casing IP20 rated. Install in a protective enclosure.
Installation Category II; Pollution Degree 2; Flame resistant
Dimensions (H x W x D)
101 x 23 x 120mm (3.98 x 0.91 x 4.72") With included antenna: 150 x 23 x 146mm (5.91 x 0.91 x 5.75")
Single unit weight 154g (5.4oz), with included antenna and plugs
Environmental conditions
Operating temp -20 to 55°C (-4 to 131°F)
Storage temp -20 to 65°C (-4 to 149°F)
Operating humidity 0–85% non-con-
densing
Altitude 2000m (6561)
Thermocouple input
Thermocouple types & ranges J -200 to 1000°C (-328 to 1832°F) K -200 to 1260°C (-328 to 2300°F) B 400 to 1800°C (752 to 3272°F) E -200 to 700°C (-328 to 1292°F) N -200 to 1300°C (-328 to 2372°F) R 0 to 1700°C (32 to 3092°F) S 0 to 1700°C (32 to 3092°F) T -200 to 400°C (-328 to 752°F)
Input impedance >500KΩ min
TC lead resistance 100Ω max
Cold junction comp. -10 to 60°C
CJC dri <0.02°C/C typical for all
inputs
Sensor open Upscale
Accuracy 0.1% of FSO±1°C typical
RTD input
3-wire RTD Pt100 (DIN 43760:1980) or Pt1000 (3-wire RTD standard)
Calibrated ranges -200 to 300°C (-328 to 572°F), 0.01°C res; -200 to 800°C (-328 to 1472°F), 0.1°C res
Sensor current 0.6mA continuous
Lead resistance 10Ω/lead max recom-
mended
Sensor fail Upscale
Accuracy 0–300°C= ±0.1°C
0–800°C= ±0.3°C
Ambient dri 0.003°C/C typical
Voltage input
Ranges ±200mV, –200mV to 1V, 0–10V, 0–18V
Input impedance >500KΩ (all ranges)
Maximum over-voltage 24V DC
Accuracy 0.1% FSO max
Linearity and repeatability
0.05% FSO max
Channel separation 0.001% max
Ambient dri 0.003%/°C
Current input
Range 0/4–20mA
Input resistance 45Ω
Max over-range
Protected by PTC to 24V DC
Linearity and repeatability
0.1% FSO max
Accuracy 0.1% FSO max
Channel separation 0.001% max
Ambient dri <50ppm/°C of FS input
Response 100msec
Digital pulse
Frequency range 0–2500Hz
Sensors Open collector (NPN, PNP)
Frequency resolution 0.1Hz
Soware modes General frequency,
Flow rate, or RPM
Accuracy ±0.5%
Potentiometer input
Potentiometer input 3-wire
Potentiometer resistance Low range
(<2KΩ) or High range (>2kΩ)
Excitation voltage Variable
Field prog. zero 0–90% of span
Field prog. span 0.1–100%
Linearity and repeatability
<±0.05% FSO typical
Response time 100msec
Temperature dri <50ppm/°C
AC current sensor input
Sensor type Current transformer (Dene Instruments ACCS-420/010)
Amperage range
Header selectable 100/150/200A; Overload 175/300/400A respectively (continuous)
Output (Representing 0–100% of full scale input range) ACCS-420 = 4–20mA DC loop powered ACCS-010 = 0–10V DC
Power supply
ACCS-420 = Loop powered, 15–36V DC ACCS-010 = Self powered
Accuracy 1% of full scale
Response time 250ms (10–90%)
Isolation voltage 2000V
Frequency 50–60Hz
Compliances
FCC ID: 2ACTT-1409 47 Code of Federal Regulations; Part
15 - Radio Frequency Devices; Subpart C - Intentional Radia­tors, including Section 15.247 - Operation in the band 2400
–2483.5MHz
AS/ANS 4268:2012 Radio equipment and systems - Short
range devices - Limits and methods of measurement
ETSI EN 300 440-2, V1.4.1, 2010 Electromagnetic compat-
ibility and Radio spectrum matters (ERM); Short Range Devices (SRD); Radio equipment to be used in the 1GHz to 40GHz fre­quency range; Part 2: Harmonised EN under article 3.23 of the R&TTE Directive
EN 301 489-3, V1.6.1, 2013 Electromagnetic compatibility
and Radio spectrum Matters (ERM); Electromagnetic Compat­ibility (EMC) standard for radio equipment and services; Part 3: Specic conditions for Short Range Devices (SRD) operating on frequencies between 9kHz and 40GHz
Easy USB setup in minutes! Visit deneinstruments.com/toolbox
P2P Product Codes
P2P-TWIN-LINK
P2P-R
P2P-I* Point-to-Point Universal Input Node
P2P-O* Point-to-Point Output Node
* Not sold separately unless for replacement
Accessories (Sold Separately)
FCC approved 3DBi monopole antenna included with all P2P units. All other accessories are not FCC approved.
WG-8DBI 8DBi Monopole antenna
WG-AEC Antenna extension cable 30cm
WG-PSU Power adaptor for 936V DC supply
BRIDGE-KEY
Point-to-Point paired I/O units
Point-to-Point Repeater Node
(Range= 2.7km [1.7mi] LOS)
USB Bridge Key for PC programming
Copyright © 2017 Dene Instruments Ltd P2P--DS-17V01 (0428)
www.deneinstruments.com
New Zealand sales@deneinstruments.co.nz AUK +64 (9) 835-1550 South Africa sales@deneinstruments.co.za USA (TX) sales@deneinstruments.com TX (214) 926-4950
The P2P-O Wireless Output Node is part of the Dene Instruments Twin Link point-to-point system.
It receives wireless transmissions from the paired Input Node (P2P-), and provides dual 4-20mA retransmission.
2x 4-20mA Analogue Outputs
For simple interface to PLC's and SCADA systems
4x digital inputs, 2x digital outputs, and 2x relays
Configure your IOs for mimicking, alarms, and sophisticated remote control of other equipment
Transmit up to 1.5km (0.9mi) Line Of Sight
Simple USB setup using Define ToolBox
Free download from defineinstruments.com/toolbox
P2P-O
Wireless Output Node
Specications
General
Power supply 9–36V DC, 2.5VA max
Isolation 1500V AC between power
supply and output channels
Simple soware programming using Dene ToolBox
Connect to the P2P- Input Node (Bridge Key required, sold separately)
Transmission
RF data rate 250Kb/s
RF frequency range 2405-2475MHz
RF receiver sensitivity -110dBm
RF transmission power +20dBm
(Optional low power setting [10dBm] selectable in soware)
Transmission range Up to 1.5km (0.9mi) LOS with supplied antenna (WG-3DBI). All nodes must be set to full power [+20dBm] for max range.
Number of RF channels 15
Up to 17 wireless nodes per mesh
Twin Link (P2P- & P2P-O) plus up to 15x Repeaters (P2P-R)
Spreading method Direct sequence
Modulation O-QPSK
Analogue Outputs
2x Analogue outputs Isolated 4–20mA or 20–4mA DC
Power supply Loop powered
Resolution 15 bits, 16000 steps
Loop drop 10V max
Linearity & repeatability 0.1% FSO
max
Accuracy 0.1% FSO max
Ambient dri 50ppm/°C FSO max
Isolation to Digital IO GND 1400Vrms
for 1min. Working voltage 125V DC
Relay Outputs
2x Relay outputs Form A relays (5A 250V AC / 5A 30V DC)
Isolation to sensor and user input commons 2300Vrms for 1min.
Working voltage 250V AC
Life expectancy 100K cycles min at full load rating
Digital IO's
4x Digital inputs Max rate 1Hz. Selectable sink/source. Suitable for clean contacts, NPN, PNP and voltage
inputs (low input <1.4V DC, high input
1.4–30V DC)
Max continuous input 20V DC
Not isolated to power supply common
2x Digital outputs Open drain (1A,
30V DC max)
Construction
35mm DIN rail mount casing IP20 rated. Install in a protective enclosure.
Installation Category II; Pollution Degree 2; Flame resistant
Dimensions (H x W x D)
101 x 23 x 120mm (3.98 x 0.91 x 4.72") With included antenna: 150 x 23 x 146mm (5.91 x 0.91 x 5.75")
Single unit weight 150g (5.3oz), with included antenna and plugs
Environmental conditions
Operating temp -20 to 55°C (-4 to 131°F)
Storage temp -20 to 65°C (-4 to 149°F)
Operating humidity 0–85% non-con-
densing
Altitude 2000m (6561)
Compliances
FCC ID: 2ACTT-1409 47 Code of Federal Regulations; Part
15 - Radio Frequency Devices; Subpart C - Intentional Radia­tors, including Section 15.247 - Operation in the band 2400
–2483.5MHz
AS/ANS 4268:2012 Radio equipment and systems - Short
range devices - Limits and methods of measurement
P2P Product Codes
P2P-TWIN-LINK
P2P-R
P2P-I* Point-to-Point Universal Input Node
P2P-O* Point-to-Point Output Node
* Not sold separately unless for replacement
Point-to-Point paired I/O units
Point-to-Point Repeater Node
ETSI EN 300 440-2, V1.4.1, 2010 Electromagnetic compat-
ibility and Radio spectrum matters (ERM); Short Range Devices (SRD); Radio equipment to be used in the 1GHz to 40GHz fre­quency range; Part 2: Harmonised EN under article 3.23 of the R&TTE Directive
EN 301 489-3, V1.6.1, 2013 Electromagnetic compatibility
and Radio spectrum Matters (ERM); Electromagnetic Compat­ibility (EMC) standard for radio equipment and services; Part 3: Specic conditions for Short Range Devices (SRD) operating on frequencies between 9kHz and 40GHz
Accessories (Sold Separately)
FCC approved 3DBi monopole antenna included with all P2P units. All other accessories are not FCC approved.
WG-8DBI 8DBi Monopole antenna
(Range= 2.7km [1.7mi] LOS)
WG-AEC Antenna extension cable 30cm
WG-PSU Power adaptor for 936V DC supply
BRIDGE-KEY
USB Bridge Key for PC programming
Set up your P2P system in minutes! Visit deneinstruments.com/toolbox
Copyright © 2017 Dene Instruments Ltd P2P-O-DS-17V01 (0428)
www.deneinstruments.com
New Zealand sales@deneinstruments.co.nz AUK +64 (9) 835-1550 South Africa sales@deneinstruments.co.za USA (TX) sales@deneinstruments.com TX (214) 926-4950
Loading...